Delhi Development Authority Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Delhi Development Authority - DDA Tender

Works
Telecommunication Services
Eprocure
Opening Date30 Oct 2024
Closing Date12 Nov 2024
Tender Amount₹ 25,30,696 
Notes
Download

Costs

Summary

M O Office Dda Building Community Hall Madipur Paschim Puri Swz

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing the 20 watt suitable for 200-240 volts ,50Hz AC supply LED Batten complete in all respect,painting ,numbering ,connection,testing etc as required.

150

507

76050

... More
Rewinding of existing damaged/burn out ceiling fan of 1200/1400 mm sweep size in all respect i/c dismantling the existing ceiling fan & refixing the same with connection,testing etc complete as required.

25

694

17350

... More
Supplying and fixing following Modular type switch/socket on the existing Modular plate & switch box including connections but excluding Modular plate etc. as required. a)5/6 A Switch, one way modular switch ISI marked

25

46

1150

... More
3 pin 5/6 A Modular socket outlet ISI marked.

25

85

2125

... More
15/16 A Switch, one way modular switch ISI marked

25

100

2500

... More
6 pin 15/16A, Modular socket outlet ISI marked.

25

142

3550

... More
Supplying and replacement 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole

20

185

3700

... More
(b) Single Pole & Neutral

10

535

5350

... More
(c) Double Pole

15

593

8895

... More
(d) Three Pole & Neutral

6

1191

7146

... More
(e) 63 A FP MCB 10 KA C curve

4

2235

8940

... More
f) 63 A DP MCB 10 KA C curve

5

1171

5855

... More
g) PVC batten 25X16 mm

20

9

180

... More
h) 16amp 3 pin plug top

10

89

890

... More
Rewiring for circuit/sub main wiring along with earth wire with the following sizes FRLS PVC insulated copper conductor, single core cable in Existing surface/recessed steel conduit as reqd. (a) 2x1.5 sq. mm + 1x1.5 sq mm earth wire

180

104

18720

... More
(b) 2x4 sq.mm +1x4 sq.mm earth wire

300

172

51600

... More
(c) 2x10 sq.mm+1x6 sq.mm earth wire

90

384

34560

... More
Supplying and replacement of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm

12

125

1500

... More
Supplying and replacement of following sq mm dia size of medium Class PVC Conduit along with accossories in surface/recess including cuttng the wall and making good the same in case of recessed conduit as required. (a) 25 sq mm PVC conduit

50

39

1950

... More
Supplying and Replacement of following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch

50

14

700

... More
5/6 amps socket 3 Pin

25

31

775

... More
15/16 A switch

30

65

1950

... More
6 pin 15/16 A socket outlet

30

81

2430

... More
Supplying &replacement of following accessories.i/c connection testing etc. complete as required. 2.5 sq. mm ISI marked, FRLS PVC insulated,single core copper conductor wire(BG-6 comm.hall+office complex)

180

38

6840

... More
1.5 sq. mm ISI marked, FRLS PVC insulated,single core copper conductor wire

300

24

7200

... More
4 sq. mm ISI marked, FRLS PVC insulated,single core copper conductor wire

360

57

20520

... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group A (BG-6 comm.hall+office complex)

25

574

14350

... More
Repairing & rewinding of following worn out parts of existing 5 HP submersible pump set (Single phase) of Kirloskar make i/c refixing, painting connection testing etc. complete as reqd. Motor Side i)Rewinding of motor ii)Gun Metal bearing bush iii)Rotor sleeve turning, grinding, etc. iv)Thrust Plate v)Water seal Pump Side i)Gun Metal Neck Ring ii)E P Impeller iii)E P Bowl/ Diffuser iv)Upper Bush (office complex)

1

10097

10097

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A

30

993

29790

... More
Supply and replacement the Buzzer Suitable for Single phase 220-240 V ,50 HZ AC supply i/c Connection testing etc as required.

10

60

600

... More
Supply and replacement of Bell Push Suitable for Single phase 220-240 V 50 HZ AC supply i/c Connection testing etc as required.

10

26

260

... More
Servicing of 50 KVA DG Set of Ashoka Leyland Make i/c following replacement of parts:- (i) B`Check Kit - 1Job (ii) Engine Oil - 10 ltr (iii) coolant-5 ltr iv) Radiator descaling-1 job v)Air filter-1 set (vi) Labour charges -1 Job (office complex)

1

13070

13070

... More
Servicing of 82.5KVA DG Set of Ashoka Leyland Make i/c following replacement of parts:- (i) B`Check Kit - 1Job ii) Engine oil-15 ltrs (iii) Coolant - 5 ltr iv) Radiator descaling-1 job v) Air filter-1 set (vi) Labour charges -1 Job (BG-6 comm.hall)

1

15827

15827

... More
Supply and replacement of stepped type modular fan regulator Suitable for Single phase 220-240 V 50 HZ AC supply i/c Connection testing etc as required.

25

299

7475

... More
Lowering of submersible pump set in the existing bore with G.I. pipes i/c replacement of existing nuts & bolts, connections of delivery line, valves cable jointing, testing etc. completed as reqd.

1

2572

2572

... More
Lifting of submersible pump sets along with G.I. pipes and accessories i/c dismantling of pump set from delivery line etc. complete as required.

1

2436

2436

... More
Dismantling the existing damaged /burn out wall fan of 400 mm sweep and rewinding the same with copper winding and replacement of ball bearing etc. and fixing the ceiling fan i/c connection, testing complete as required(office complex)

2

624

1248

... More
Servicing of window/ split type air conditioners of 1.5 ton/2 ton capacity i/c cleaning with chemical of condenser coil, evaporation coil, lubricating & washing of complete A.C. with front grill and Replacement of air filter Pads, re-installation of air conditioner in the position testing etc. as required.(office complex)

2

814

1628

... More
Servicing of water cooler 100/ 120 ltrs. Capacity oiling of fan, cleaning of Base plate with chemical and cleaning of water tank, and painting etc. complete as required.(office complex) 2 times in a year

2

1018

2036

... More
Supplying and replacement of burnt compressor of the following items i/c gas charging, testing of pressure and commissioning etc. as required. a)1.5 ton /2 ton window/ split air conditioners(office complex)

1

9114

9114

... More
b) 100/ 120 ltrs water coolers

1

9114

9114

... More
Diagnose and repair the compressor leakage then after gas charging with required or filling with existing gas,Testing of pressure and commissioning etc as required. (a)Window type air conditioner 1.5 ton/Split type air conditioner 1.5 ton/water cooler(office complex)

2

3358

6716

... More
Supplying and replacement of following parts of water coolers/ air conditioners i/c connection, testing etc. as required. a) Running capacitor 36 mfd (office complex)

1

349

349

... More
b) Running capacitor 15 mfd

1

149

149

... More
c) Starting capacitor 80/100 mfd

1

349

349

... More
d) Overload Protectector/overload relay

1

373

373

... More
e) Thermostate

1

373

373

... More
f) Front grill

1

2300

2300

... More
g) Air filter pads

1

1000

1000

... More
h) PCB repair

1

9500

9500

... More
Supplying & replacement of fan motor i/c connection testing complete as required. a) Window type air conditioner 1.5 ton/2 ton (office complex)

1

3908

3908

... More
b) 100/ 120 ltrs water coolers

1

3908

3908

... More
Supplying and Replacement with regulator cooler kit (motor) suitable for 18"/20" size desert cooler i/c dismantling of existing desert cooler kit (motor), connection, testing etc.(office complex)

14

1914

26796

... More
Supplying and Replacement of desert cooler body of size for 18"/20" cooler fan. Upper cover, Lower tank and support should be made of 18 SWG GI sheet, Parde should be made of 20 SWG GI sheet and depth of tank should be minimum 7", with switches complete etc. as required.(office complex)

9

4758

42822

... More
Supplying and fixing of wood wool pad set (set of 3 pieces) with steel wire jali, suitable for 18"/20" desert cooler i/c disposing the existing pad, cleaning of water tank compete etc. as reqd.(office complex)

30

254

7620

... More
Cleaning, denting and painting of following Items i/c supplying of cleaning materials, checking of nuts, bolts & safety pins/keys making them good in proper condition , numbering, testing etc. as reqd. a) Desert Cooler (office complex)

30

211

6330

... More
b) Cooler Stand

30

113

3390

... More
Supplying & fixing of cooler stand having height approx 80-100 cm (upto window of room) & length ,breadth according to cooler body Size having 18"/20" i/c fixing, testing,Connection etc required.(office complex)

5

1108

5540

... More
Supplying and Replacement of Submersible pump set suitable for 18”/20” desert cooler i/c dismantling, refixing, connection, testing etc complete as required.(office complex)

15

403

6045

... More
Supply, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

15

2730

40950

... More
Supply, fixing and replacement of wall fan 300 mm sweep i/c connection, testing etc. complete as reqd.(office complex)

5

2052

10260

... More
Supplying and fixing of 300 mm sweep size exhaust fan with complete in all respec with louvers suitable for single phase 230 volt,50 Hz AC supply i/c connection, testing etc. complete as reqd.(office complex+ staff qtr)

8

2138

17104

... More
Supplying and fixing of following capacity of capacitor in the existing desert cooler/fans i/c connection, testing etc complete as reqd. a) 4 MFD(office complex)

15

82

1230

... More
b) 3.15 MFD

10

75

750

... More
Supplying and Replacement of suitable plastic air blade in the existing 18”/20” desert cooler i/c dismantling, refixing, connection, testing etc complete as required.(office complex)

5

235

1175

... More
Supplying and Replacement of three core copper 1.5 sq.mm wire in the existing 18”/20” desert cooler i/c dismantling, refixing, connection, testing etc complete as required.(office complex)

50

72

3600

... More
Supplying and Fixing the 3 Pin top in the existing desert cooler wire i/c connection, testing etc. complete as reqd.(office complex)

20

67

1340

... More
Supplying of following sizes of XLPE insulated of 1.1 KV Grade Al. cond. armoured power cable including connection, testing etc. as required. a)3.5 x35 sq. mm.

100

327

32700

... More
Supplying of 3 HP dewatering pump (weda pump) outlet size 50 mm having solid handling capacity 35 mm,head range 10-18m,discharge 640-100LPM i/c testing commisiong etc complete as required.

1

27814

27814

... More
Supplying and replacement of 30 watt street light fitting suitable for single phase 220-240 volt,50Hz AC supply i/c dismantling the existing CFL fitting and refixing the same in all respect i/c connection ,testing and commissioning etc complete as required.(BG-6 comm.hall)

7

1268

8876

... More
SITC of following type of LED light fitting (IP 66 protection) with complete in all respect i/c making connections ,earthing the same and to meet the requirement as per technical specifications etc. as required. (a) 150Watt Flood light fitting(BG-6 comm. hall)

10

5198

51980

... More
Supplying & Replacement of following type of LED light fitting (IP 66 protection) with complete in all respect i/c making connections ,earthing the same and to meet the requirement as per technical specifications etc. as required. (a) 45 Watt LED street light fitting (office complex)

15

2374

35610

... More
Repairing ,rewinding & servicing of 1 HP single phase dewatering pump set and refixing the same i/c labour charges connection testing commissiong etc as required.(BG-6 comm.hall)

1

1790

1790

... More
Supplying of following sizes of XLPE insulated of 1.1 KV Grade Al. cond. armoured power cable including connection, testing etc. as required. a)2C x16 sq. mm.

500

181

90500

... More
Laying of one number PVC insulated andPVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground i/c excavation and refilling the trench etc as required,but excluding sand cushioning and protective covering. Upto 35 sq.mm

350

200

70000

... More
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on wall surface as required. Upto 35 sq.mm (clamped with 1 mm thick saddle)

250

55

13750

... More
Supplying & replacement of storage type lead acid battery of 12 V , 180 AH for diesel engine pump sets i/c P/F battery cable , thimbles, connections, testing etc. as reqd. (BG-6 comm.hall)

1

12440

12440

... More
Supplying & Replacement of 4 Pole controler relay of following rating in the existing panel board suitable for 415 volt, 50 Hz, 3 Phase AC supply i/c connection testing commissioning etc. complete as reqd. a) MXO 22E(2NO+2NC) (BG-6 comm.hall)

1

1157

1157

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. a)250 A TP& N

1

10293

10293

... More
Supplying and replacement of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreader in the existing cubical panel board the including drilling holes in cubical panel making connection testing etc required. 250Amp 36KA FPMCCB

1

17510

17510

... More
125 A 36 KA FPMCCB

1

8209

8209

... More
Servicing/repairing of 53 KW Diesel engine (Kirloskar make engine) i/c supply and replacement of following items i/c testing etc complete as required a)S/R of Oil Filter SPIN type-1 No. b) S/R of Diesel Filter -1 set. c) S/R of Air cleaner element-1 set d) S/R of Coolant-5 ltr e) S/R of Battery terminal-2 No f)S/R of Engine oil-20 ltr g)S/R of fuel pump i/c calibration and repairing og governor,nozzle pumps,injectors etc as required--1 Job (BG-6 comm.hall)

1

15749

15749

... More
Refilling of existing ABC type portable fire extinguisher of capacity of 10 kg including dismantling removing the existing gas and after refilling re-fixing in the same position of the complete as required.(office complex)

32

1234

39488



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.