Delhi Development Authority Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi Development Authority - DDA Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Nov 2024
Closing Soon16 Nov 2024
Tender Amount₹ 76,20,153
Costs
EMD
₹ 1,52,403Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
M O Of Completed Schemes Shops Under Swz
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DDA_833840_1Tender No
23/EE(E)/ELD-10/DDA/2024-25Tender Authority
Delhi Development Authority ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
b) 12 V,150 AH
2
10554
21108
Supplying & replacement of 20W LED batten made of polycarbonate housing in place of the existing florescent tube fitting i/c connection, & testing etc. complete as reqd.
110
377
41470
Supplying and replacement of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreader along with suitable size of SS enclosure in built nutral link to accommodate the MCCB including drilling holes in cubical panel making connection testing etc required . 250 Amp 4P, 50 KA
5
21733
108665
Supplying & Replacement of 3 Pole Power Contactors of following rating in the existing panel board suitable for 415 volt, 50 Hz, 3 Phase AC supply i/c connection testing commissioning etc. complete as reqd. a) 125 Amp,AC-3, Type ML-6
1
27702
27702
b) 100 Amp, AC-3, Type ML-4
1
14839
14839
c)45 Amp, AC-3, Type ML-3
1
10339
10339
Providing, replacement, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paintof required shade complete as required : a) 80 mm dia.
20
1885
37700
b) 100 mm dia.
10
2555
25550
c) 150 mm dia.
10
3574
35740
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. a)63 A TP& N
12
3144
37728
b) 200 A TP&N
4
9689
38756
c) 125 A TP&N
3
7189
21567
d) 315 A TP&N
2
14566
29132
Supply and drawing of following sizes of FRLS PVC insulated ,single core copper conductor cable in the existing surcace / recessed steel / PVC conduit as required. a)2x1.5 sq. mm
400
70
28000
b)2x4 sq. mm
300
147
44100
Dismantling and repairing i/c S/R of following worn out parts of existing 12.5HP clear water pump of kirloskar make suitable for operation on 415 volts , 3 phase ,50 hz ,AC supply i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd:- (i) S/R of Pump shaft (SS)- 1 No.
1
4434
4434
(ii) S/R of Bal bearing - 2 Nos.
1
1176
1176
(iii) S/R of Gland plate- 2 Set
1
1390
1390
(iv) S/R of Gland bush- 2 Nos .
1
2951
2951
(v) S/R of impeller- 1 No.
1
10307
10307
Dismantling and rewinding i/c S/R of following worn out parts of existing 12.5HP kirloskar make Induction motor(for clear water) i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd:- (i) Rewinding of 12.5 HP motor - 1No.
1
7072
7072
(ii) S/R of Connection plate - 1 No.
1
474
474
(iii) S/R of Coupling- 1 No.
1
2363
2363
(iv) S/R of ball bearing - 2 Nos.
1
1356
1356
(v) Rotor balancing turning-1 No.
1
1165
1165
Supplying of 3 HP sewage submersible pump outlet size 50 mm having solid handling capacity 35 mm,head range 10-18m,discharge 640-100LPM i/c testing commisiong etc complete as required.
1
32707
32707
Supply and replacement of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.
complete as required
10
2730
27300
Servicing of 100/125 KVA DG set (Cummins make engine) i/c supply and replacement of following items testing etc complete as required.
i) Oil Filter - 2 Nos
ii)Diesel Filter -2Nos.
iii) Air cleaner element- 1 set
iv) Coolant- 5 ltr
v)Battery terminal- 4 Nos.
vi)Engine oil-35 ltr
3
27272
81816
Servicing of 25/40 KVA DG Set (Kirloskar make engine) i/c supply and replacement of following items testing etc complete as required
i) Oil Filter -1 No.
ii) Diesel Filter -1 set.
iii) Air cleaner element-1 set
iv) Coolant-3 ltr
v) Battery terminal-2 Nos.
vi) Engine oil-10 ltr
2
11067
22134
Repairing of AMF panel of 125KVA//100KVA D.G set with supplying and replacement of following parts i/c connection testing& commissiong etc complete as required. a) panel comlpete wiring with materials-1No b)Battery charger 24 volt -1 No c)Relay 8 pin-2 nos. d)Relay 4 pin-2 Nos e)starter Relay-1 No f) push button -2 Nos. g)panel repairing and servicing charges.
1
26973
26973
Repairing of AMF panel of 40KVA D.G set with supplying and replacement of following parts i/c connection testing& commissiong etc complete as required. a) panel comlpete wiring with materials-1No b)Battery charger 12 volt -1 No c)Relay 8 pin-2 nos. d)Relay 4 pin-2 Nos e)starter Relay-1 No f) push button -2 Nos. g)panel repairing and servicing charges.
1
24561
24561
Repairing of AMF panel of 25 KVA D.G set with supplying and replacement of following parts i/c connection testing& commissiong etc complete as required. a) panel comlpete wiring with materials-1No b)Battery charger 12 volt -1 No c)Relay 8 pin-2 nos. d)Relay 4 pin-2 Nos e)starter Relay-1 No f) contactor 70 amp-2 Nos. g)panel repairing and servicing charges.
1
24122
24122
Dismantling and repairing of Following parts of existing Jockey Pumps of existing make couple with 15 HP Motor i/c reassembling, reinstallation the same, connection testing complete as required.
S/R S.S Shaft – 1 No
1
4745
4745
S/R of shaft sleeve – 1 No
1
4126
4126
S/R Ball Bearing – 2 Nos
1
1647
1647
S/R Impeller– 1 No
1
10835
10835
S/R of packing Kit – 1 Set
1
567
567
Gland Plate- 1 No
1
772
772
Servicing of 75/93 BHP Fire Fighting Diesal Engine i/c supply and replacement of following items testing etc complete as required.
i) Oil Filter - 2 Nos
ii)Diesel Filter -2Nos.
iii) Air cleaner element- 1 set
iv) Coolant- 5 ltr
v)Battery terminal- 4 Nos.
vi)Engine oil-35 ltr
3
27272
81816
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 6 Zone.
5
12178
60890
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
100
1071
107100
Supplying & Replacement of 12 volt 26 AH. Lead Acid battery i/c dismantling the existing burnt battery and fixing the new one battery with connection, testing etc. complete as required.
2
3374
6748
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
300
173
51900
Supply and Replacement of following parts of starter suitable upto 12.5 HP centrifugal pump sets suitable for 415 volt,50 Hz AC supply,i/c dismantling the Existing damaged/burnt out i/c connection,testing etc completed as required.a) single phase preventor
4
1803
7212
Supplying,installation,testing and commissiong of 150 watt energyefficient 5700K temperature LED flood light luminaries,with pressure die cast IP66 housing, secondary lens with 120lm/W efficacy and superior aesthetics i/c testing,connection etc required.
15
5428
81420
Supplying of following size of XLPE aluminum conductor armoured power cable of 1.1 KV grade including providing & fixing thimbles connection,testing etc as required at site.
a) 2CX10 sq.mm Size
500
132
66000
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kv grade of following size on wall surface as required.
a) UP to 35 sq.mm ( clamped with 1mm thick saddle.)
500
55
27500
Supplying and replacement of 300mm sweep size exhaust fan having steel body for single phase 230Volt,50 Hz AC supply i/c connection testing etc as required.
5
2494
12470
Dismantling and reparing i/c S/R of worn out parts of existing 3HP Dewatering pump(sewage sub.type/weda type) i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd:-
2
6168
12336
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%