Delhi Development Authority Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi Development Authority - DDA Tender
Electrical and Electronics
Eprocure
Opening Date18 Jun 2024
Closing Date8 Jul 2024
Tender Amount₹ 23,33,955
Costs
EMD
₹ 46,679Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Upgradation Of Various Sports Complexes/golf Courses.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DDA_812340_1Bid Award Id
ViewTender No
09/EE(E)/ELD-2/DDA/2024-25 (Re-Call)Tender Authority
Delhi Development Authority ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
120
63720
531
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
120
120120
1001
Supply, installation testing & commissioning of rigid UPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.etc complete as required.
-
-
-
40 mm dia
70
17710
253
Supply & installation of control cum transmission wiring of 4 core x 6 sqmm copper in suitable pvc conduits between indoor and out door unit. etc complete as required.
40
12920
323
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
A)25 mm
20
3080
154
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts,and coverof cable tray etc.as required.
-
-
-
150 mm width x 50 mm depth x 1.6 mm thickness
15
11415
761
300 mm width x 50 mm depth x 1.6 mm thickness
15
15360
1024
Supply of Refrigerant gas R-410 for top up etc complete as required.
90
85590
951
Supply of Power cable of following sizes XLPE insulated copper armoured conductor cable to VRF outdoor unit from main electrical panal. The cost shall include all necessary supports clamps etc as necessary as required .
-
-
-
A) 4C x 10 sqmm
170
159120
936
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
A)Upto 35 sq. mm (clamped with 1mm thick saddle)
150
8700
58
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
A)Upto 35 sq. mm (clamped with 1mm thick saddle)
20
960
48
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
A)4C x 10 sqmm
4
1144
286
Dismantling of already existing rectangular duct wherever required and reinstall it after fixing of 25 mm thickness closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber wherever required and complete it with additional duct, MS Work with Nut bolt, Fasteners ,fabrication work and complete the duct work in all respects including cleaning of existing duct in respect to make the complete AC units functional .nothing extra will be paid for this item .Item also includes the cost of Aluminium grills wherever required to complete the finishing work.This Item includes complete installation testing and commissioning of duct system with arrangement of scaffholding, ladder for installation etc complete as required.
1
48508
48508
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
400
47600
119
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
4
34916
8729
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of
following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
A)Double pole
6
4188
698
Comprehensive Maintenance of Complete installation (as per provided in Part-I with already installed inventory) for first year after completion defect liability period as per terms and conditions attached complete etc as required.
12
62208
5184
Comprehensive Maintenance of Complete installation (as per provided in Part-I with already installed inventory) for next year after completion item No. 16
12
64080
5340
Comprehensive Maintenance of Complete installation (as per provided in Part-I with already installed inventory) for next year after completion item No. 17
12
66000
5500
Comprehensive Maintenance of Complete installation (as per provided in Part-I with already installed inventory) for next year after completion item No. 18
12
67980
5665