Delhi Development Authority Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Delhi Development Authority - DDA Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Jan 2025
Closing Soon15 Jan 2025
Tender Amount₹ 76,37,035 
Notes
Download

Costs

Summary

Running, Maintenance Operation Of Internal, External And High Mast Lighting, Substation An Dg Set, Fire Fighting Fire Sprinkler System, Addressable Fire Alarm System, Lift, Submersible Pump, Maintenance Of Plc And Scada System For Sports Lighting

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3½ Cx300 sq.mm

1

6319

6319

... More
3½ Cx240 sq.mm

1

5089

5089

... More
3½ Cx185 sq.mm

1

4695

4695

... More
Charges for detection of cable fault in the existing underground LT cable of different sizes i/c pin pointing in the same by FLC equipment etc. complete as reqd.

1

9027

9027

... More
Dehydration &filtration of transformer oil ( 1250 KVA transformer indoor type) to upgrade the dielectric strength of oil upto 50 KV as required.

1

12743

12743

... More
Servicing of H.T. VCB complete with dismantling, cleaning, alignment, adjustment of gaps between phases, lubricating all moving parts adjustment for smooth mechanical operation etc complete as required.

3

8495

25485

... More
Testing and Calibration of IDMT relay with secondary injection test set i.e. cleaning servicing of contacts tightening of loose contacts testing repair etc., complete as required.

3

3717

11151

... More
Servicing / Overhauling 2000/2500 Amp ACB's with dismantling, cleaning, alignment, adjustment of gaps between phase, lubricating all moving parts adjustment for smooth mechanical operation etc complete as required.

4

7965

31860

... More
Servicing / Overhauling 1000/1250 Amp ACB's with dismantling, cleaning, alignment, adjustment of gaps between phase, lubricating all moving parts adjustment for smooth mechanical operation etc complete as required.

5

6902

34510

... More
Digging of Pit for providing cable joint as per site located by fault Locator machine including refilling of soil complete as required.

1

2006

2006

... More
Repairing & servicing of existing 415 V 630 KVAR Microprocessor based APFC panels-3 Nos. with supply and replacement of following items i/c connection testing and commissioning etc. complete as required. Description Qty. a. MOC25 TP CAPACITOR DUTY CONTACTOR 24 Nos. b. 25 KVAR 7% DETUNED REACTOR, Aluminium WOUND 24 Nos. c. 50 KVAR CAPACITOR BANKS, 440V, MPP TYPE, HEAVY DUTY 01 No. d. 27.7 KVAR CAPACITOR BANKS, 480V, MPP TYPE, HEAVY DUTY 24 Nos. e. Auto Manual Selector Switch 01 No. g. 12 STEP APFC RELAY, MICROPROCESSOR BASED, 1 C.T OPERATED 2 Nos. i. IND. LIGHT 220V, LED TYPE,22.5mm DIA. RED, YELLOW & BLUE - 30 Nos. Note: Satisfactory test certificate also be submitted by the agency.

1

892047

892047

... More
Operation of fire fighting and sprinkler system including routine & preventive checking/ maintenance(as per annexure - C) etc. as per inventory and additional terms and conditions attached And Running, Maintenance and operation of addressable Fire alarm system as per inventory and terms & conditions enclosed by deploying the following staff :- a) Operator – 3 Nos. (1 No. in each shift total 3 shifts i.e. 6 AM to 2 PM & 2 PM to 10 PM & 10PM to 6AM) b) Khallalsi – 3 Nos. (1 No. in each shift total 3 shifts i.e. 6 AM to 2 PM & 2 PM to 10 PM & 10PM to 6AM)

3

187243

561729

... More
Refilling of different type of fire extinguisher Minimax make including cartage, loading, unloading and testing etc. complete as reqd.

-

-

-

... More
10 kg. DCP type

1

977

977

... More
5 kg. DCP type

10

855

8550

... More
4.5 kg CO2 type

10

814

8140

... More
9 liters Mechanical Foam type

3

733

2199

... More
9 liters water type gas cartridge

1

651

651

... More
Painting (of fire fighting installation)with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with one or more coats on old work.

1700

90

153000

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :

-

-

-

... More
Stainless Steel (Grade 304)

3

4602

13806

... More
Supply &Replacement, Installation, testing and commissioning of Edward make Photo cum heat deductor modal SIGA 2PHS + Base complete as required

5

3176

15880

... More
Supply &Replacement, Installation, testing and commissioning of Edward make Manual Call Point Modal SIGA 271/278 complete as required.

3

3885

11655

... More
Operation of 6 Nos. lifts as per inventory enclosed as per terms & conditions by deploying following staff :- i) Rescue Operator (for lift) : 1 No. (1 No. in general shift i.e. 9 AM to 5 PM)

3

34635

103905

... More
(Operation of Bio Composter machine ) Operation and Maintenance of Bio Composter machine (Capacity- 500 Kg). as per inventory enclosed as per terms & conditions by deploying following staff :- i) Operator : 1 No. (1 No. in general shift i.e. 9 AM to 5 PM)

3

34635

103905

... More
Sub Head - X (Maintenance & operation of IEI and Submersible Pump ) Running, Maintenance & operation of internal electrical installations, external lighting and high mast lighting, PLC/SCADA & submersible pump sets as per inventory and Additional conditions enclosed by deploying following staff. i) Electrician cum operator - 3 Nos.( one in each shift total 3 shifts.) ii) Khallasi - 2 Nos.( one in each shift total 2 shifts.) All tools and plants including tower wagon suitable to maintained fittings mounted up to height 12 mtrs. shall be made available at the site throughout the contract period. And also maintenance including routine/ preventive maintenance, repairs and replacement of defective components/ accessories of PLC Panels and SCADA System of Sports Lighting of Match Court/ Show court as per additional conditions and Annexure enclosed etc. complete as required.

3

164035

492105

... More
Supplying and Replacement (including deduction of cost for replaced item) of FRLS PVC insulated copper conductor wire of following size in the existing surface/ recessed conduit i/c connection, testing etc.as required.

-

-

-

... More
1x 1.5 sq.mm

400

24

9600

... More
1x 2.5 sq.mm

400

38

15200

... More
1x 4.0 sq.mm

200

57

11400

... More
Supply and Replacement (including deduction of cost for replaced item) following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.

-

-

-

... More
5/6 Amp Switch

40

107

4280

... More
15/16 Amp Switch

20

162

3240

... More
3 pin 5/6 Amp Socket outlet

20

126

2520

... More
6 pin 15/16 Amp socket outlet

15

203

3045

... More
Supplying and Replacement (including deduction of cost for replaced item) following rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB/ Electrical Panel Board/ feeder pillar/ street light pole complete with connections, testing and commissioning etc. as required.

-

-

-

... More
5 to 32 Amp SP MCB "C" series

10

265

2650

... More
40 Amp TPN MCB "C" series

5

2607

13035

... More
40 Amp DP MCB "C" series

5

1340

6700

... More
16 to 32 Amp DP MCB "C" series

5

679

3395

... More
63 Amp four pole MCB "C" series

5

2741

13705

... More
Providing and Replacement (including deduction of cost for replaced item) following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
100 A, 16 KA, TPMCCB with Terminal spreaders

2

3908

7816

... More
125 A, 16 KA,TPMCCB with Terminal spreaders

2

4988

9976

... More
250 A, 35 KA,TPMCCB with Terminal spreaders

1

14361

14361

... More
Supplying and Replacement (including deduction of cost for replaced item) following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

2

1069

2138

... More
Supply of PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable (As per IS 7098 (Part-1) of 1.1 KV grade in existing DWC pipe i/c connection testing etc.as required.

-

-

-

... More
2 x10 sq.mm

400

209

83600

... More
2 x 16 Sqmm

100

237

23700

... More
3.5 x 25 sq.mm

100

372

37200

... More
3.5 x 50 Sqmm

100

637

63700

... More
Supply and Replacement (including deduction of cost for replaced item) 4’ long 18-20 watt LED Batten –AL- anodized indoor decorative LED extruded IP-20 fitting with opal diffuser connection testing etc. as required.

50

563

28150

... More
Comprehensive maintenance i/c routine/ preventive & break down maintenance i/c repair/ replacement of components of PLC/SCADA system for show court and badminton court lighting as per inventory installed at site of work and terms & conditions attached etc.

3

79593

238779

... More
Lifting out of submersible pump set from the exiting bore well up to the required depth along-with existing G.I. pipes and accessories etc. i/c dismantling of G.I pipe and disconnecting the sub. cable etc. complete as reqd.

4

2806

11224

... More
Lowering of sub. pump set in the existing bore well up to the required depth along with existing G.I pipe and sub. Cable etc, water proof jointing of sub. cable. Replacement of reqd. nuts, bolts, washers and packing, nipple, reducer, connection testing, etc. complete as reqd.

4

3015

12060

... More
Supplying of copper conductor flat submersible cable of following size i/c testing etc. complete as reqd.

-

-

-

... More
3 x 2.5 sq.mm

100

109

10900

... More
3 x 4 sq.mm

100

161

16100

... More
3 x 6 sq.mm

100

237

23700

... More
Supplying of following size of double G.I. flanged (ISI marked ) GI pipe 'B' class duly threaded & welded with necessary pipe fittings, bends, elbow etc. complete as reqd. a) 65 mm dia.

18

787

14166

... More
Supplying of following size of double G.I. flanged (ISI marked ) GI pipe 'B' class duly threaded & welded with necessary pipe fittings, bends, elbow etc. complete as reqd. a) 50 mm dia.

30

624

18720

... More
Repairing and rewinding of Submersible motors of following capacity with cartage, dismantling, reassembling i/c supply & replacement/ repairing of all damaged parts of motors and making good for operation i/c connection, testing, painting etc. complete as required.

-

-

-

... More
Upto 2 HP single/ three Phase Submersible motor

2

3385

6770

... More
5 HP/7.5HP three Phase Submersible motor

3

6592

19776

... More
10 HP three Phase Submersible motor

1

8909

8909

... More
Repairing of Submersible Pump 3 Phase of following stages & dia. with cartage, dismantling, reassembling i/c supply & replacement/ repairing of all damaged parts of pump and making good for operation i/c connection, testing, painting etc. complete as required.

-

-

-

... More
Upto all stage 4" dia. Submersible pump set

3

2446

7338

... More
Upto all stage 6" dia. Submersible pump set

3

2830

8490

... More
Supply and Replacement of following Control Gear/ accessories in the existing installation for the Electric Panel of submersible pump set i/c connection with suitable size thimbles and fixing the panel in the existing feeder with nut bolts after drilling etc. complete as required.

-

-

-

... More
Single Phase Preventor

2

885

1770

... More
D.O.L. Starter (9-14 Amp.)

2

2115

4230

... More
Supplying of single pump pressure booster with tank of 1 HP (Pump with SS Impeller). The pump sets shall be suitable for the following duties. a) Head Range:- 10-50 Mtr. Discharge Range :- 83-13 LPM. Minimum HP/KW:- 1HP/0.75KW, Suction/Delivery pipe - 25x25mm

2

34383

68766

... More
Supplying of sub. Pump set duly coupled with suitable rating 3 phase, 415 volt, 50Hz, sub. Motor. The pump sets shall be suitable for the following duties. a) Head Range:- 18-106 Mtr. Discharge Range :- 500-100 LPM. Minimum HP/KW:- 7.5HP/9 Stage. Outlet:- 50 mm

2

53861

107722

... More
Supplying of LED Flood Light fixture not more than 500 watt and lumen output not less than 60000 Lumens (having minimum fixture efficacy of 120 Lm/Watt ) fitting with suitable clamp. The luminaire should be confirming to IP 66 & IK 08 (for impact resistance), External Surge protection of 15 KV/7.5 KA and Internal Surge protection of 5 KV/2.5 KA (integrated to the driver unit) CCT = 5700 ± 350° K, CRI ≥70, TLCI≥90, Life L70≥ 50K hrs. Fitting may be integrated type (with driver unit) or non integrated type (with separate driver unit). The LM 79, LM 80 & TTC Certificates shall have to be submitted form NABL/ UL/ third party lab to verify the above parameters) The complete item shall be as per specification and additional conditions attached, complete etc. as required.

96

33879

3252384

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. A). Above 185 sq. mm and upto 400 sq. mm

300

490

147000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.