Delhi Development Authority Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi Development Authority - DDA Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Oct 2024
Closing Date5 Nov 2024
Tender Amount₹ 11,70,410
Costs
EMD
₹ 23,408Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
M/o Staff Quarters At Mayur Vihar Special Repairs.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DDA_832978_1Bid Award Id
ViewTender No
16/EE/ELD-1/DDA/NIT/2024-25Tender Authority
Delhi Development Authority ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
3.0) Supply and replacement of capacitor of following capacity etc. as required.
-
-
-
3.1) 3.15 MFD for exhaust fan
25
42
1050
3.2) 2.5 MFD for ceiling fan
60
34
2040
4.0) Supply and replacement of fan regulator switch in the existing electric board i/c connection, testing etc. as required.
50
207
10350
5.0) Rewinding of 48" ceiling fan oiling, greasing servicing, cleaning dismantaling and re- assembling along with replacement of bearings, testing, commissoning etc. as required.
50
452
22600
6.0) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
-
-
-
6.1) 5/6 amps switch
60
52
3120
6.2) 15/16 A switch
50
121
6050
6.3) 3 pin 5/6 A socket outlet
50
69
3450
6.4) 6 pin 15/16 A socket outlet
50
137
6850
7.0) Supply and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface /recessed, M.S./ PVC conduit as required.
-
-
-
7.1) 1 x 1.5 sq. mm.
500
45
22500
7.2) 3 x 1.5 sq. mm
300
95
28500
7.3) 2 x 2.5 sq. mm
150
98
14700
7.4) 3 x 4 sq. mm.
100
206
20600
8.0) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
8.1) Single pole
50
256
12800
8.2) Double pole
25
656
16400
9.0) Supplying and fixing following rating "C" curve MCB in the existing DB complete with connections, testing and commissioning etc. as required.
-
-
-
9.1) 40 Amp Double pole
8
493
3944
9.2) 63 Amp Double pole
5
636
3180
9.3) 63 Amp Triple pole
4
1003
4012
10.0) Supplying and fixing of call bell/buzzer complete with connections, testing and commissioning etc. as required.
25
99
2475
11.0) Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
12
894
10728
12.0) Supplying and fixing of Laminated/MS sheet with required size to cover all the existing distributing board and panel including screw,washer and accessories etc as required.
35
95
3325
13.0) Replacement of existing obsolete/unrepairable LED street lights with supply of new 30 watt LED street light with IP -66 protrection & IK08 impact resistance i/c replacement of damaged or missing brackets on existing poles with testing & commissioning etc. as required.
15
2590
38850
14.0) Supplying & replacement of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz,i/c Testing and Commissioning single phase AC Supply, earthing etc. complete as required.
30
1678
50340
15.0) Replacement & installation of exhaust fan(metallic body) of size 12" i/c connections,making good the damages ,iron angle & painting with screws,nuts & bolts etc. complete as required.
15
1838
27570