Delhi Development Authority Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 55,151Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DDA_811751_1Bid Award Id
ViewTender No
10/EE/ELD-2/DDA/2024-25Tender Authority
Delhi Development Authority ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
-
-
-
above 185 sq mm and upto 400 sq mm
820
109880
134
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
-
-
-
120 mm dia (OD-63 mm & ID-51 mm nominal)
390
143520
368
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
-
-
-
120 mm dia (OD-63 mm & ID-51 mm nominal)
390
96720
248
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
-
-
-
3.5 x 240 sqmm (62 mm)
4
4108
1027
3.5 x 300 sq mm(70 mm)
2
2390
1195
SITC of outdoor type Feeder pillar, cubical type fully compartmentalized made out of 2mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder coated painting through seven-tank process facility for pricking and degreasing, of suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick for incoming and outgoing cables entry, erected on cement concrete foundation made, complete with painting, interconnections, earthing, provision for protection from rain dust, fixed on MS angle iron frame work of size 50 mm x50 mm x 6 mm (NS) 100 cm long legs out of which 50 cm duly grouted in cement concrete 1:2:4 (1 cement: 2 sand: 4 stone) aggregate etc complete as required.
Incoming
1 No 250 Amps, 4P, MCCB (36kA) with thermomagnetic release, Handle and all required accessories.
1 No. Ampere meter & 1 no. Volt meter with selector switch
Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.
Busbar
Electrolytic higElectrolytic high conductivity aluminium three phase and neutral busbars rated at 415V, 400 amps, 50Hz, AC, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints
OUTGOINGS:-
160 Amp 36 KA TPN=3 Nos
100 Amp 36 KA TPN=1 No
63 Amp 25 KA TPN =3 Nos
32 Amp DP=4 No
1
195163
195163
SITC of outdoor type Feeder pillar, cubical type fully compartmentalized made out of 2mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder coated painting through seven-tank process facility for pricking and degreasing, of suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick for incoming and outgoing cables entry, erected on cement concrete foundation made, complete with painting, interconnections, earthing, provision for protection from rain dust, fixed on MS angle iron frame work of size 50 mm x50 mm x 6 mm (NS) 100 cm long legs out of which 50 cm duly grouted in cement concrete 1:2:4 (1 cement: 2 sand: 4 stone) aggregate etc complete as required.
Incoming
1 No 125 Amps, 4P, MCCB (36kA) with thermomagnetic release, Handle and all required accessories.
1 No. Ampere meter & 1 no. Volt meter with selector switch
Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.
Busbar
Electrolytic higElectrolytic high conductivity aluminium three phase and neutral busbars rated at 415V, 200 amps, 50Hz, AC, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints
OUTGOINGS:-
100 Amp MCCB FP=1 No
63 Amp TPN=1 No. 32 A DP =1 No 7.5 hp 3 phase starter=1 no
1
111364
111364
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
4
27420
6855
making trench less under ground hole across the road /pavements/cement concret pathway at adepth of about 1 meter by means of manual augour to drawing the pipe (up to 120 mm dia )/cable i/c making excavation on both side of road /pathway for making trenchless hole & refilling the same with excavated earth /soil after laying pipe /cable through trench less i/c proper ramming dressing, watering as per instruction of engineer-in-charge etc as required.
390
273000
700
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements