Defence Research And Development Organisation Tender

... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Defence Research And Development Organisation - DRDO Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date5 Jan 2019
Closing Date30 Jan 2019
Tender Amount₹ 73,65,39,795 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
a)Ordinary rock

883

-

-

... More
b)Hard rock (blasting prohibited)

2117

-

-

... More
Filling with available earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 100 m and all lift.

11785

-

-

... More
Supplying and filling in plinth with river/locally available sand under floors including, watering, ramming consolidating and dressing complete.

50

-

-

... More
CHAPTER - II : CONCRETE WORK

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

786

-

-

... More
CHAPTER - III : REINFORCED CONCRETE WORK

-

-

-

... More
Centering & shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
a) Foundations, footings, bases of columns, etc. for mass concrete.

2838

-

-

... More
b) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

11349

-

-

... More
c) Suspended floors, roofs, landings, balconies and access platform.

2238

-

-

... More
d) Lintels, beams, plinth beams, girders, bressumers and cantilevers.

3758

-

-

... More
e) Columns, Pillars, Piers, Abutments, Posts and Struts.

3201

-

-

... More
f) Stairs, (excluding landings) except spiral- staircases

77

-

-

... More
g) Edges of slabs and breaks in floors and walls. Under 20 cm wide

187

-

-

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).

-

-

-

... More
(a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).

1216

-

-

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth and above plinth. (a) Thermo-Mechanically Treated bars. (Fe-500-D)

444118

-

-

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

7462

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).

-

-

-

... More
(a) All works upto plinth level

2201

-

-

... More
(b) All works above plinth level upto floor V level

761

-

-

... More
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. (a) Providing M-30 grade concrete instead of M-25 grade BMC / RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

1179

-

-

... More
Add/Deduct for using extra cement in the items of design mix over and above the specified cement content therein.

786

-

-

... More
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. Make:- Pentron or equivalent.

3726

-

-

... More
CHAPTER - IV : BRICK

-

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (a) Cement mortar 1:6 (1 cement : 6 coarse sand)

428

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (a) Cement mortar 1:6 (1 cement : 6 coarse sand)

518

-

-

... More
CHAPTER -V : WOOD AND P.V.C WORK

-

-

-

... More
Providing and fixing aluminium tower bolts ISI marked powder coated Garde C (minimum thickness of powder coating 50 micron as per IS:13871) transparent or dyed to required colour or shade with necessary screws etc. complete :

-

-

-

... More
(a) 250x10 mm

10

-

-

... More
(b) 200x10 mm

10

-

-

... More
Providing and fixing aluminium handles ISI marked powder coated Garde C (minimum thickness of powder coating 50 micron as per IS:13871) transparent or dyed to required colour or shade with necessary screws etc. complete :

-

-

-

... More
(a) 125mm

10

-

-

... More
(b) 100mm

10

-

-

... More
CHAPTER - VI : STEEL WORK

-

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

9508

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

45168

-

-

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.

-

-

-

... More
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

425

-

-

... More
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

11133

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. a) Hot finished welded type tubes

2085

-

-

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. a) M.S. tube

17

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.

-

-

-

... More
(a) 80x1.20 mm M.S. laths with 1.20 mm thick top cover

11

-

-

... More
Providing and fixing ball bearing for rolling shutters.

3

-

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. a) Made of G.I. wire of dia 4 mm

84

-

-

... More
CHAPTER - VII : FLOORING WORK

-

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : a) 22-25 mm thick.

541

-

-

... More
Kota stone slabs 22-25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

43

-

-

... More
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.

112

-

-

... More
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.50 metre.

112

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

1000

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

450

-

-

... More
CHAPTER - VIII : ROOFING WORK

-

-

-

... More
Providing and fixing in required profile twin wall 6mm thick Lexan thermo clean of GE equivalent one side UV protected polycarbonate sheet in required colour & shade M.S. tubular/ structural frame work with 40 micron powder coated aluminium Aleox section set of standard size and weather resistant Neoprin EPDM rubber gasket on both side of Alcox section 80 as to make the fabricated structure water proof. The Alcox section shall be rigidly to supporting frame work alongwith the sheet with self taping self drilling steel screws fixed approx 150mm centre to centre. The open end edges of Polycarbonate sheet shall be provided with aluminium channel of size 10x10x1.5mm and weight not less than 0.20Kg/m with necessary self taping screws. The joints of the structure shall be properly sealed with silicon sealants wherever required so as to make the fabricated structure totally water proof. The rate shall include the cost of all materials, such as aluminium Alcox section set and charnel, EPDM gasket, self taping screws, nuts bolts and silicon sealant and all the labour and material required to cut, fabricate and fix the structure complete as per direction of Engineer Incharge (Cost of supporting steel tubular structural frame work provided shall be paid for separately). Finished sheet area shall be measured for the purpose of payment.

3215

-

-

... More
CHAPTER - IX : WATER PROOFING WORK

-

-

-

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. a) Using rough kota stone.

1214

-

-

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : a) Using rough kota stone.

873

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : a) Serrated with central bulb (225 mm wide, 8-11 mm thick)

746

-

-

... More
CHAPTER -X : FINISHING WORK

-

-

-

... More
12 mm cement plaster of mix : (a) 1:6(1 cement : 6 fine sand )

43

-

-

... More
15 mm cement plaster on rough side of single or half brick wall of mix : (b) 1:6 (1 cement: 6 fine sand)

43

-

-

... More
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. (a) 12 mm cement plaster

50

-

-

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.

9049

-

-

... More
6 mm cement plaster of mix : (a) 1:3 (1 cement: 3 fine sand)

8970

-

-

... More
Neat cement punning

1503

-

-

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

881

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1885

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : a) New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

13383

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : a) Two or more coats on new work

1919

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: a) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

1269

-

-

... More
Providing and fixing glass reinforcement concrete (GRC) screen/moulding/ cornice as per approved pattern , design, colour of desired size etc. of approved make. The cornice should be made from 53 grade white portland cement manufactured by separated ISI company. Quantity, fine silica, sand, alkali resistant glass fiber manufactured by saintgobain or equivalent, super plasticizer and polymers manufactured by BASF or equivalent and UV resistant & synthetic inorganic pigments should be used for pigmentation manufactured by Bayberries (Germany) or equivalent. The material casting should take place synthetic rubber /FRP mould manufacture by Reckli or equivalent. The fixing of screen/cornice/moulding should be dry fixing is to be done by S.S. Steel (SS- 304 grade) L-shaped clamps, dash fasteners and pins/cement mortar or any suitable means etc. complete as per site requirements and as per direction of Engineer-in-charge & as per architectural drawing complete a) Screen/ jali of thickness 50mm with internal members thickness ranging between 25- 30mm, having atleast 40-50% void space as per patern/ design of arch.

485

-

-

... More
CHAPTER -XI : ALUMINIUM WORK

-

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene gaskit etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :

-

-

-

... More
(a) For fixed portion (i) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)

61

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing aluminium hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). (i) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)

71

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (i) With float glass panes of 5.0 mm thickness

55

-

-

... More
Filling the gap in between aluminium/UPVC frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. a) Upto 5mm depth and 5 mm width

116

-

-

... More
Providing and fixing aluminium casement stays, ISI marked, powder coated grade C (minimum thickness of powder coating 50 micron as per IS:13871) transparent or dyed to required colour and shade, with necessary screws etc. complete.

20

-

-

... More
CHAPTER -XII : MISCELLANEOUS WORKS

-

-

-

... More
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)

1658

-

-

... More
Providing and fixing horizontal R.B.T. reinforced barbed wire upto 3 mtr height fixed with angle iron poles including accessories like clamps, staples, turn buckles etc complete or as per direction by Engineer-in-charge

4974

-

-

... More
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.

27

-

-

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. a) In cement mortar

937

-

-

... More
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : a) In cement mortar

10

-

-

... More
PART-B : ROAD & SIGNAGES WORKS

-

-

-

... More
Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up undre OMC condition, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 1Km and lift upto 1.5 m : a) All kinds of soil

14035

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil.

222

-

-

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). a) All works upto plinth level

1386

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations repared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. a) On steel work

50

-

-

... More
Providing and applying prime coat using using slow setting bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom : a) On W.M.M. @ 0.75 Kg I sqm

633

-

-

... More
Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. a) With rapid setting bitumen emulsion i) On bituminous surface @ 0.25kg/sqm

2733

-

-

... More
Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, huttering & neat cement punning inside the bell mouth etc. all complete.

570

-

-

... More
Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be ested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.

1088

-

-

... More
Providing and fixing solar road studs (Model - RKSS01 of RK Security solution or equivalent) of size of 132x122x32mm having specifications: No of Led's - 6 LED's(3 Each side) Material - Aluminum Alloy and PC Installation Remarks - Gum Fix Water Proof Grade - IP67 All complete, as per directions of Engineer-in-Charge.

363

-

-

... More
Providing and fixing Plastic speed breakers (Model - RKPB50-1 of RK Security solution or equivalent) of size of 500x400x50mm all complete, as per directions of Engineer-in-Charge.

186

-

-

... More
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge. a) 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @5% (percentage by weight of total mix) and lime filler @2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity.

137

-

-

... More
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. a) 40/50 mm compacted thickness with bitumen of grade VG-30 @5.5% (percentage by weight of total mix) and lime filler @3% (percentage by weight of Aggregate) prepared in drum Type Hot Mix Plant of 60-90 TPH capacity.

93

-

-

... More
Manufacturing, supplying & fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bilingual), symbols & borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat & pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted & fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end & including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade & of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black & white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over & including appropriate priming coat including all leads & lifts etc. complete as per drawing, specification and direction of Engineer--in-charge.

-

-

-

... More
Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm

20

-

-

... More
Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm

10

-

-

... More
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge. (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). a) Overhead informatory road signage

12

-

-

... More
Designing, Manufacturing, supplying and fixing sign boards made up of 4mm thick ACP sheet, face to be fully covered with 90 micron Vinyl sheeting in approved colour combination including subject matter, message , symbols and borders etc., as per approved design pasted on substrate by an adhesive backing and fixing the same with suitable sized aluminium alloy rivets @ 20cm c/c to back support frame of stainless steel along with theft resistant measures, including making holes in pipes, angles, flats, compete as per drawing, specification and direction of Engineer-in-charge. (SS suport frame, post shall be paid separately).

35

-

-

... More
Providing and fixing stainless steel ( Grade 304) Post/Frame for external signage made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) as per approved design and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the post in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). ( Cement Concrete 1:2:4 shall be paid for separately).

700

-

-

... More
Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.

1521

-

-

... More
Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge.

1707

-

-

... More
Providing and fixing post delineators made of ABS round body fitted with 2 nos 100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder coated anti-rust and anti theft steel to be installed as per direction of Engineer-in-charge.

90

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

649

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. a) With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

3879

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.

431

-

-

... More
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin-charge.

1811

-

-

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with minimum 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation , finishing to lines and grades as per drawing including transparent/white separation membrane of 125 micron, dowel bar, tie rod, admixtures as approved, tining or brooms with wire brush, spraying curing compound during laying, cutting contraction, expansion, construction and longitudinal joints, joint filler, debonding strip, backer rod, sealant primer, joint sealant, wet curing with hessian cloths for at least 14 days etc complete as per specifications and directions of Engineer-in-charge.

3616

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin-Charge.

-

-

-

... More
60mm thick Cement concrete paver block of M-35 grade with approved colour, design & pattern

17203

-

-

... More
80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.

1948

-

-

... More
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly ncased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly ainted over priming coat , reinforcement to be welded at dges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge

231

-

-

... More
Providing and fixing Convex mirror 1000 mm size for Lateral visibility at road junctions and assessed in a road junction where drivers have to give way can observe lateral traffic through a convex mirror visibility on one or both sides of an intersection including all cost etc complete as per specifications and direction of Engineer-in charge.

10

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates to a thickness not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment and return wall to the full height compacted to a firm condition complete as per drawing & as per clause 2200, 2504.2.2. of technical specifications for Road & Bridge works MoRTH (5th revision) & 710.1.4.of IRC:78 and as per instruction of Engineer in charge.

58

-

-

... More
Supplying, fabricating welded water tight drainage spout assembly to dimensions shown on drawing of dia not less than 100mm with galvanized steel conforming to IS 226 & fixing in position with suitable fixtures at specified locations on bridge decks including painting two coats with bituminous paint sealed with sealant as per IS 1834 around the spout to the deck slab as per clause 2705 of technical specification for road and bridge works MORT&H (5th revision) & as directed by engineer in charge.

26

-

-

... More
Supplying, Providing, fixing weep holes in plain / reinforced concrete abutments / return walls with 100mm dia PVC pipe extending through the full width of the structure with slope of one vertical x 20 horizontal towards drainage face completeas per drawings and as per section 2200, 2700 ( Clause 2706) of technical specifications for Road & Bridge works MORTH (5th revision) & as per direction of Engineer in charge.

327

-

-

... More
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete

-

-

-

... More
(a) 600 mm dia RCC pipes

88

-

-

... More
(b) 900 mm dia RCC pipes

88

-

-

... More
PART-C : EXTERNAL WATER SUPPLY

-

-

-

... More
Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc. And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil. a) All kind of soil

-

-

-

... More
i) Pipes, cables etc, not exceeding 80 mm dia.

1865

-

-

... More
ii) Pipes, cables etc, exceeding 80mm dia but not exeeding 300 mm dia

2794

-

-

... More
Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, depth upto 1.5M including getting out the excavated materials, returming the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc., stacking serviceable material for measurements And disposing of unserviceable material as directed within a lead of 50 m. a) Ordinary rock

-

-

-

... More
i) Pipes, cables etc, exceeding 80mm dia but not exeeding 300 mm dia

798

-

-

... More
ii) Hard rock (blastig prihibited) Pipes, cables etc, exceeding 80mm dia but not exeeding 300 mm dia

399

-

-

... More
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc. External Work

-

-

-

... More
(a) 25mm dia nominal bore

191

-

-

... More
(b) 32mm dia nominal bore

70

-

-

... More
(c) 40mm dia nominal bore

260

-

-

... More
(d) 50mm dia nominal bore

212

-

-

... More
(e) 65mm dia nominal bore

490

-

-

... More
(f) 80mm dia nominal bore

642

-

-

... More
Providing and laying S&S Centrifugally Cast (Spun)/ Ductile Iron Pipes confirming to IS: 8329 fixing.

-

-

-

... More
(a)100 mm dia Ductile Iron Class K-9 pipes

3536

-

-

... More
(b) 150 mm dia Ductile Iron Class K-9 pipes

120

-

-

... More
Providing and laying Double Flanged (Screwed / Welded) Centrifugally (Spun Ductile Iron Pipes of Class K-9 conferming to IS 8329

-

-

-

... More
(a) 100 mm dia C.I. Ductile Iron Class K-9 pipes

456

-

-

... More
(b) 150 mm dia C.I. Ductile Iron Class K-9 pipes

20

-

-

... More
Providing and laying DI specials of class K12 suitable for push on jointing as per IS 9523. a) Upto 600 mm. dia

78

-

-

... More
Providing and laying D.I. specials of class K-12 Suitable for mechanical jointing as per IS 9523 a) Upto 600mm dia

8

-

-

... More
Providing push-on-joint to Centrifugally (Spun) Cast Iron Pipes 0r Ductile Iron Pipes includingtesting of joints and inclusive the cost of rubber gasket.

-

-

-

... More
(a) 100 mm dia. Pipes

2593

-

-

... More
(b) 150 mm dia. Pipes

88

-

-

... More
Providing and fixing C.I. Sluice valve( with cap ) complete with bolt, nuts, rubber insertions etc. a) 100 mm diameter i) Class- II

8

-

-

... More
Constructing masonary chamber 30x30x50cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock with C.I. Surface box 100x100x75 mm ( inside) with hinged cover fixed in cement concrete slab 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement:5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design with F.P.S. bricks. a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

13

-

-

... More
Constructing masonary chamber 60x60x75cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. Surface box 100mm top diameter , 160 mm bottom diameter and 180 mm deep ( inside ) with chained lid and RCC top slab 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement:5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design with F.P.S. bricks. a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

26

-

-

... More
Constructing masonary chamber 90x90x100cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. Surface box 100mm top diameter , 160 mm bottom diameter and 180 mm deep ( inside ) with chained lid and RCC top slab 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement:5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design with F.P.S. bricks. a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

2

-

-

... More
Painting GI pipes and fittings with two coats of anti corrosive bitumestic paint of approved quality.

-

-

-

... More
(a) 25mm dia nominal bore

134

-

-

... More
(b) 32mm dia nominal bore

49

-

-

... More
(c) 40mm dia nominal bore

182

-

-

... More
(d) 50mm dia nominal bore

148

-

-

... More
(e) 65mm dia nominal bore

343

-

-

... More
(f) 80mm dia nominal bore

449

-

-

... More
Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work.

-

-

-

... More
(a) 25mm dia nominal bore

134

-

-

... More
(b) 32mm dia nominal bore

49

-

-

... More
(c) 40mm dia nominal bore

182

-

-

... More
(d) 50mm dia nominal bore

148

-

-

... More
(e) 65mm dia nominal bore

343

-

-

... More
(f) 80mm dia nominal bore

449

-

-

... More
Providing & fixing C.I double air valve of approved quality with bolts , nuts , rubber insertion etc complete (The tail pieces , tapers etc if required will be paid separately )

-

-

-

... More
(a) 80 mm dia

4

-

-

... More
(b) 100 mm dia

4

-

-

... More
Providing & fixing of following sizes of butterfly valve of rating PN 16, wafer type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft, conforming to IS-13095 of the following sizes complete with cast iron hand lever companion flanges, bolts, nuts, washers & inserted rubber gaskets, as required and as per enclosed specification.

-

-

-

... More
(a) 65mm dia

6

-

-

... More
(b) 80mm dia

8

-

-

... More
Providing and fixing brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum working pressure of 16 kg/cm2.

-

-

-

... More
(a) 25mm nominal bore

50

-

-

... More
(b) 32mm nominal bore

5

-

-

... More
(c) 50mm nominal bore

8

-

-

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (a) 80mm dia nominal bore

4

-

-

... More
Supply, Installation, Testing & commisioning of Pop up Impact Rotary Sprinkler having radius of throw 10 m - 13 m, Discharge 0.12 Lps to 0.22 Lps. At 2.0 Bar to 3.0 Bars Irrigation System with all required accessories complete.

42

-

-

... More
Supply, Installation, Testing & commisioning of Pop up Spray Sprinkler having radius of throw 2.5 m - 5.5 m, Discharge 0.01 Lps to 0.35 Lps. At 1.0 Bar to 3.0 Bars Irrigation System with all required accessories complete.

200

-

-

... More
Providing and fixing HDPE pipes Gread - PE 63 working pressure PN 6 kg/cm2 including all fittings with or without access i.e bends, junctions, cowls, offsets, etc.and jointing with solvent cement and excavation, refilling and disposal of surplus earth, including cutting holes in walls and floors ,wherever required and making good the same, complete as directed by the Engineer in charge.

-

-

-

... More
(a) 25mm outer dia.

1213

-

-

... More
(b) 32mm outer dia.

50

-

-

... More
(c) 40mm outer dia.

70

-

-

... More
(d) 50mm outer dia.

60

-

-

... More
(e) 65mm outer dia.

300

-

-

... More
(f) 80mm outer dia.

1600

-

-

... More
PART-D : SEWERAGE SYESTEM

-

-

-

... More
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc. And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil. a) All kind of soil i) Pipes, cables etc, exceeding 80mm dia but not exeeding 300 mm dia

1752

-

-

... More
Extra for Excavation trenches for pipes, cables etc. in all kind of soil for depth exceeding 1.5m but not exceding 3m (Rate is over corresponding basic item for depth up to 1.5m)

350

-

-

... More
Extra for Excavation trenches for pipes, cables etc. in all kind of soil for depth exceeding 3m but not exceding 4.5m (Rate is over corresponding basic item for depth up to 1.5m)

70

-

-

... More
Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, depth upto 1.5M including getting out the excavated materials, returming the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc., stacking serviceable material for measurements And disposing of unserviceable material as directed within a lead of 50 m.

-

-

-

... More
a) Ordinary rock i) Pipes, cables etc, exceeding 80mm dia but not exeeding 300 mm dia

501

-

-

... More
b) Hard rock (blastig prihibited) i) Pipes, cables etc, exceeding 80mm dia but not exeeding 300 mm dia

250

-

-

... More
Extra for Excavation trenches for pipes, cables etc. in all kind of soil for depth exceeding 1.5m but not exceding 3m (Rate is over corresponding basic item for depth up to 1.5m)

100

-

-

... More
Extra for Excavation trenches for pipes, cables etc. in all kind of soil for depth exceeding 3m but not exceding 4.5m (Rate is over corresponding basic item for depth up to 1.5m)

20

-

-

... More
Providing, laying & jointing HDPE DWC (SN-8 Pipe ) complete in all respect.

-

-

-

... More
(a) 200 mm diameter

1263

-

-

... More
(b) 250 mm diameter

1240

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) up to hunches RCC pipes sewer/storm drainage including in bed for pipes to be laid in trenches as per standard details.

-

-

-

... More
(a) 200 mm diameter

1137

-

-

... More
(b) 250 mm diameter

1116

-

-

... More
Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. a) Inside size 90x80 cm and 45 cm deep including CI Cover with frame (light duty as per IS:12592) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg). i) with common burnt clay F.P.S.(non module) brick of class designation 7.5

60

-

-

... More
Extra for depth for manholes i) Size 90 x 80 cm a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

12

-

-

... More
Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 0.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

50

-

-

... More
Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . i) with common burnt clay F.P.S.(non module) brick of class designation 7.5

12

-

-

... More
Constructing Brick Masonry circular type manhole 1.22 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 1.68m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

24

-

-

... More
Extra depth for circuler type manholes 1.22 m internal dia ( at bottom ) beyond 1.68m to 2.29 m . a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

8

-

-

... More
Constructing Brick Masonry circular type manhole 1.52 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 2.30m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately). a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

20

-

-

... More
Extra depth for circuler type manholes 1.52 m internal dia ( at bottom ) beyond 2.30m . a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

5

-

-

... More
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS:10910 on12mm dia steel bar conforming to IS:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protrude legs having 2mm tread on top surface by ribbing or chequering besides necessary & adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with dtand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification make to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.

564

-

-

... More
PART-E : ROOF TOP RAIN WATER SYSTEM

-

-

-

... More
Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc. And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil. a) All kind of soil

-

-

-

... More
Pipes, cables etc, exceeding 80mm dia but not exeeding 300 mm dia

910

-

-

... More
Pipes, cables etc, exceeding 300mm dia but not exeeding 600 mm dia

203

-

-

... More
Extra for Excavation trenches for pipes, cables etc. in all kind of soil for depth exceeding 1.5m but not exceding 3m (Rate is over corresponding basic item for depth up to 1.5m)

182

-

-

... More
Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, depth upto 1.5M including getting out the excavated materials, returming the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc., stacking serviceable material for measurements And disposing of unserviceable material as directed within a lead of 50 m. a) Ordinary rock

-

-

-

... More
i) Pipes, cables etc, exceeding 80mm dia but not exeeding 300 mm dia.

74

-

-

... More
ii) Pipes, cables etc, exceeding 300mm dia but not exeeding 600 mm dia.

144

-

-

... More
Hard rock (blastig prihibited)

-

-

-

... More
i) Pipes, cables etc, exceeding 80mm dia but not exeeding 300 mm dia.

37

-

-

... More
ii) Pipes, cables etc, exceeding 300mm dia but not exeeding 600 mm dia.

72

-

-

... More
Extra for Excavation trenches for pipes, cables etc. in all kind of soil for depth exceeding 1.5m but not exceding 3m (Rate is over corresponding basic item for depth up to 1.5m)

44

-

-

... More
Providing and laying Non pressure NP2 RCC Pipes with collars jointed with stiff mixture of cement mortar in the propoertion of 1:2 (1 cement : 2 fine sand) including testing and jointing etc complete.

-

-

-

... More
(a) 150mm dia RCC Pipe

300

-

-

... More
(b) 250mm dia RCC Pipe

1000

-

-

... More
(c) 300mm dia RCC Pipe

700

-

-

... More
(d) 350mm dia RCC Pipe

20

-

-

... More
Providing and laying cement concrete 1:5:10 ( 1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) alround DWC/RCC pipes sewer/storm drainage including in bed for pipes to be laid in trenches as per standard details.

-

-

-

... More
(a) 150 mm diameter

270

-

-

... More
(b) 250 mm diameter

900

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up haunches of DWC/RCC. pipes including bed concrete as per standard design :

-

-

-

... More
(a) 300mm dia RCC Pipe

630

-

-

... More
(b) 350mm dia RCC Pipe

18

-

-

... More
Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) & making necessary channel in Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 0.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately). a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

30

-

-

... More
Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

3

-

-

... More
Constructing Brick Masonry circular type manhole 1.22 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) & making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 1.68m deep with SFRC cover & frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately). a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

20

-

-

... More
Extra depth for circuler type manholes 1.22 m internal dia ( at bottom ) beyond 1.68m to 2.29 m . a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

2

-

-

... More
Constructing Brick Masonry circular type manhole 1.52 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 2.30m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately). a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

5

-

-

... More
Extra depth for circuler type manholes 1.52 m internal dia ( at bottom ) beyond 2.30m. a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

1

-

-

... More
Constructing brick masonary road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement :4 coarse sand ) including 500x500 mm C.I cover with frame complete as per standard design. a) with common burnt clay F.P.S.(non module) brick of class designation 7.5

143

-

-

... More
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS:10910 on12mm dia steel bar conforming to IS:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protrude legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with dtand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification make to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.

322

-

-

... More
Construction of modular Polymer based Structure rain water harvesting pit 32 cum. (For Storage purpose) including following items. Earth work excavation with JCB/excavators in all types of soil/Ordinary rock/Hard rock and with a lift up to 5 meter. Material for base work (gravel/stone chips and double washed river sand) Dressing Compaction - of base soil Soil disposal - disposal of extracted soil from the site to inside the boundary walls of the building up to a maximumdistance of 0.5km Geo textile - to avoid invasion of soil provide stability to the tank and improve quality of water within the tank with tensile strength. EPDM Liner Over Geotextile to retail water.all around of RWH.EPDM Liner is a nominal 45-mil and 60-mil thick non-reinforced Ethylene Propylene Diene Terpolymer . Modular RWH modules material size (685x410x408 mm). Backfilling of the area constructed in and around after compacting them properly. FRP Micro filter capable of removing soilds. Riser for filter extension.

3

-

-

... More
Construction of modular type rain water harvesting pit 32 cum. (For Recharge purpose) including following items. Drilling of bore well: (90 metre) Injection well insertion Upvc pipe 6'' diameter having a load capacity of 6kg/sqm. Injection well insertion slotted pipes for clog resistent of rain water and reducing possibility of carrying soild. Solvent & screws for joing pipes with each other also for joinig end caps and bell plugs for bore. Clamps for keeping the pipe safe and holding the pipe while to ground level. Bell plug - supplying and fixing of bell plug with each bore well. End caps - supplying and fixing of end caps at the top of each bore well. Supply of bentonite fore bore wells drilling in order to give support and prevent from collapsing. Gravel filling for packing of empty space in the bore and to provide stability to the inserted pipes. Compressor/Boki cleaning- Earth work excavation with JCB/excavators in all types of soil/Ordinary rock/Hard rock and with a lift up to 5 meter. Material for base work (gravel/ston chips and double washed river sand) Dressing Compaction - of base soil Soil disposal - disposal of extracted soil from the site to inside the boundary walls of the building up to a maximumdistance of 0.5km Geo textile - to avoid invasion of soil provide stability to the tank and improve quality of water within the tank with tensile strength. Modular RWH modules material (685x410x408 mm) Backfilling of the area constructed in and around after compacting them properly. FRP Micro filter capable of removing soilds. Riser for filter extension.

5

-

-

... More
Construction of brick masonry Desilting chamber of size 200x150x20cm Effective depth before rainy well with precast concrete block in cement mortar 1:4 (1 cement : 4 coarse sand) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand; 8 graded stone aggregate 40mm nominal size), inside and outside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement inside and rough plaster on outside, including fixing of grating , neatly finished with 2 nos.manhole cover complete in all respects including necessary excavation, refilling and disposal of surplus earth, complete as per attached Sketch.

8

-

-

... More
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C.pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (For Road Crossing) a) 450mm dia RCC Pipe

250

-

-

... More
PART-F : WATER SUPPLY PUMPS & EQUIPMENTS AND WATER TREATMENT UNIT

-

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, up to 90 metre depth below ground level. a) All Types of Soil i) 400mm dia

180

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. a) All Types of Soil i) 400mm dia

60

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. a) 200 mm nominal size dia.

180

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC plain slotted (having slot of size 1.6/3.2 mm) of required dia, conforming to IS: 4985, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. a) 200 mm nominal size dia

60

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

20

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

40

-

-

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

40

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

200

-

-

... More
Providing and fixing suitable size threaded pvc cap the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: a) 200 mm dia

2

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. a) 200 mm clamp.

2

-

-

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). a) 200 mm dia

2

-

-

... More
Supplying & installation Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connected to TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with ISI marked of making connection suitable for tube-well/D.C.B. The job includes screwing and welding of flanges on G.I. riser pipes installation, complete fittings accessories with riser pipes jointing of electrical cables other connections making switch board electrical connections, all labour for testing of submersible pump and supply of water to water mains complete in all respects. Discharge 200 LPM. Head 120 m HP/Load 7.5 (Approx)

2

-

-

... More
Pumps Vertical/horizontal monoblock centrifugal transfer pumping set with SS-316 body and SS-316 impeller, SS-316 shaft mechanical seal, connected to a TEFC induction motor suitable for 415 volts ± 3% phase 50 cycles AC supply with a common suction header with valves on main connecting & pumps inlet and a common delivery header with valves, includingt water shock absorber, non return valves with MS galvanized supports and painting with one coat of primer and two coats of synthetic enamel paint including a 100mm dia pressure gauge, Vibration eliminating pads under foundation, all mounted on a common base plate of MS 80x40mm I section bolted to RCC foundation, including control panel complete in all respects. (i) FILTER FEED PUMPS No. of Pumps: 3 (2 Working + 1 Stand by ) Capacity : 400lpm Head : 30m

3

-

-

... More
Domestic Water Supply Pump (Hydropneumatic System With variable Speed System) Providing, fixing and testing of packaged fixed skid mounted hydropneumatic system comprising of :- Vertical, inline multistage centrifugal pumping set with stainless steel SS-316 stage casing and SS-316 impellers with stainless steel SS-316 shaft as per IEC standards and SS-316 suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles. No. and capacity of Pressure Vessel – 02 Nos. x 100 Ltrs

-

-

-

... More
Control Panel with programmable logic controller (PLC) for cyclic operation of pumps. Pump working sequence should change after every operation. Contractor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter. Control panel should also consist of cooling fan. Pressure switches bellow type fitted with micro switch and having maximum pressure and differential scale should confirming BS-6134 standards and IP55 protection class. Stainless steel suction and delevery header, ball valve on each pump on section delivery side, non return valves, Y stainer complete in all respect. Ball valves to be used should be Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement. Complete set system to be mounted on a common base frame and shall follow following duty.

-

-

-

... More
(ii) DOMASTIC WATER TRANSFER PUMPS No. of Pumps: 3 (2 Working + 1 Stand by ) Capacity : 500lpm Head : 85m

3

-

-

... More
(iii) FLUSHING WATER TRANSFER PUMPS No. of Pumps: 3 (2 Working + 1 Stand by ) Capacity : 420lpm Head : 85m

3

-

-

... More
(iv) IRRIGATION WATER TRANSFER PUMPS No. of Pumps: 3 (2 Working + 1 Stand by ) Capacity : 300lpm Head : 60m

3

-

-

... More
Providing and fixing Vertical Downflow Filter in MS fabricated in accordance with IS:2825 from minimum 6 mm thick M.S. plate on shell and minimum 8 mm thick M.S. plate on dished ends, epoxy coated construction.The filter shall have : a) One no. pressure tight manholes and at least one no. pressure tight side hole for maintenance purposes. b) Initial charge of Filter Media. c) Complete underdrain system and raw water distributor as per manufacturer's design. Complete MS C Class frontal face piping conforming to IS:1239) and valves battery with CI Butterfly valves, pressure gauges and sampling points at inlet and outlet. etc. covering all functions of service, backwash, rinse, air release etc. e) Pressure gauges (100 mm dia bourdon type pressure gauge)/ sampling points as per manufacturer design. f) All internal parts of the filtration plant shall be coated with two coats of epoxy paint after thorough sand blasting. All external surfaces of the plant including piping shall be coated with two coats of red iron oxide/zinc chromate primer followed by two coats of high gloss enamel paint . g) The filter shall be complete with all gaskets/fasteners of standard quality as required. h) The filter shall be designed to give rated output at given raw water quality and flow rate without any operational problem and should not get any loss of performance as long as the operating pressure remains within the given range. Any additional provision is required to make the item complete, the same should be included herein.

-

-

-

... More
(i) Dual Media filter Capacity - 48000 lph Filtration rate - 16500 lph/m2 Filter dia approx. 1500 mm Working pressure: 4.5 kg/cm2 Test pressure : 7.0 kg/cm2

1

-

-

... More
POST CHLORINATION OF WATER Supply, installation, testing and commissioning of Online electronic chemical solution dosing system comprising of electronic metering pump (with both frequency and stroke length controls to control the dosage rate between 10-100 % of rated maximum capacity), virgin HDPE chemical grade solution tank of rquired capacity, necessary injection fitting assembly, foot valve cum strainer and suction and delivery tubing etc. upto the point of injection complete in all respects as required. For Cholorination of filtered water Dosing capacity : 0-6 ltrs. per hour, Dosing Head : 3.5 kg/cm2

1

-

-

... More
Sump Pumps for Drainage Supply only Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connected to TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables, with both pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect. a) IN (1 Nos.Pump Room,1 Nos.STP,3 Nos.Modular Harvesting Pit) No. of Pumps: 2 (1 Working + 1 Standby ) Capacity : 250 lpm Head : 10m

5

-

-

... More
To switch on the pumps (including Raw Water Pump,Domestic water supply pump etc.) when the level of water in the supply water tank is low and to cut off the pump when the level in the receiving water tank is high and switch off the pumps when the level of water in the supply water tank is low. To indicate 5 levels of water in all tanks through a control panel with LEDs To start the pumps in a cyclic order. The system shall be complete to ensure automatic quotation of pump in accordance to water level in respective tanks. The Contractor will include all the under ground and over head tanks and all the pumps as required for level control in this item

1

-

-

... More
Providing and fixing G.I. pipes to IS 1239 (heavy class) with GI fittings, flanges & clamps & galvanized MS structural supports including cutting and making good the walls etc. complete.

-

-

-

... More
40 mm dia

5

-

-

... More
50 mm dia

10

-

-

... More
65 mm dia

25

-

-

... More
80 mm dia

20

-

-

... More
100mm dia

50

-

-

... More
150mm dia

30

-

-

... More
Painting GI pipes (heavy class) with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved prming coat including galvanized MS supports and clamps as directed by the Engineer-in-charge (shade as per pipe colour code).

-

-

-

... More
40 mm dia

5

-

-

... More
50 mm dia

10

-

-

... More
65 mm dia

25

-

-

... More
80 mm dia

20

-

-

... More
100mm dia

50

-

-

... More
150mm dia

30

-

-

... More
Providing & fixing of following sizes of butterfly valve of rating PN 16, wafer type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft, conforming to IS-13095 of the following sizes complete with cast iron hand lever companion flanges, bolts, nuts, washers & inserted rubber gaskets, as required and as per enclosed specification.

-

-

-

... More
65mm dia

5

-

-

... More
80mm dia

5

-

-

... More
100mm dia

6

-

-

... More
PART-G : SEWERAGE TREATMENT PLANT (STP)

-

-

-

... More
Design, Installation testing & commisioning of Sewerage treatment plant in MBR (MEMBRANE BIO REACTOR TECHNOLOGY) process electro Mech. work only, Tertiary treatment completely for Domestic Sewege capciaty 700 cum/day. Outlet Parameter should be match for using the water for Gardening & Flushing purpose. Bidder should include following items as specified below suitable for 700 cum/day STP. (Bidder Must visit the site before quote) Depth of Incomming sewer 4m to be consider.

-

-

-

... More
a) The STP shall be designed based on the following parameters: Daily average flow - 700 Cum / Day pH - 6.5 – 8.5 BOD5 - 250 – 450 Mg/L S. Solids - 200 – 400 Mg/L COD - 400 – 600 Mg/L Oil & Grease - 30 Mg / L

-

-

-

... More
b) Effluent discharge standard after treatment pH - 6.0 – 8.5 BOD5 - Less than 5Mg/L S. Solids - Less than 5 Mg/L COD - Less than 40 Mg/L Oil & Grease - Nil E Coli - Nil

-

-

-

... More
c) Sewerage treatment plant contaning following Electro Mech. Items including 5 years O & M 2 Nos. Stainless Steel-316 Perforated Corrugated Screen of fabricated through 5mm thick plate having holes of 8 mm at a distance of 10 mm with suitable lifting arrangement. mechanical punched hole fine screen for 2-3 mm size complete as required MOC - SS 304. Level controller cum indicator. Equalization Transfer pump (1 Working +1 standby). 2 No. twin type rotary air blowers (1W + 1S) for Aeration Tank and Equlisation tank. 2 No. twin type rotary air blowers (1W + 1S) for TW membrane scouring system. Disc type, EPDM membrane based, non clog type air dispersion system for Imported fine bubble membrane diffusers for equalisation tank, aeration tank & sludge holding tank, MBR tank,MS pipe (C Class),SS Piping ( Schedule 10),Butterfly Valve,Non-Return Valve,Ball Valve,MS Class 'B'with hot dip galvanized puddle flange,instrument for the auto operation of System and saftey.

-

-

-

... More
MBR module immersed type with permeater. Automation of complete plant from raw effluent pump to permeate pump out put with proper flow control. Ultravoilet dis-infection unit. MBR Permeate pump with VFD (1 Working +1 standby). Sludge Recycling Pump (2 Working +1 standby) (Solid handling size for this pump shal be 7-10 mm). Hypo solution dosing pump comprising of FRP tank with inlet / outlet connection. Basket type Centrifuge Machine 48'' with Perforated Plate-4mm thick, SS 304 Main Shaft-En 8, Base Frame-MS Channel.Basket Size: 1200 (Dia). Self priming sludge Feed pump (1 Working +1 standby). Electrical Panel with Cable, Earthing. Sewerage treatment plant 700 cum/day complete following above items.

1

-

-

... More
PART-H : FIRE SUPPRESSION

-

-

-

... More
Supply, fixing, testing and commissioning of Automatic linear pneumatic Tube Detection based Clean Agent System for Electrical Panels ( Firetrace Tube Panel Protection System), consisting of the following components: (For Main Distribution Panel,Essential Power Panel, Main Lighting Panel, AC power Panels & Fire Pump Panel)

-

-

-

... More
2 KG Clean Agent system complete with all necessary HFC 227 ea , Fitted with CE & PI Mariked DLP Valve ,fitting ,support ,and accessories,connected with valve.

20

-

-

... More
5 KG Clean Agent system complete with all necessary HFC 227 ea , Fitted with CE & PI Mariked DLP Valve ,fitting ,support ,and accessories,connected with valve.

11

-

-

... More
Supply, insatlation, testing and commissioning End of Line Adaptor.

31

-

-

... More
Supply, insatlation, testing and commissioning Pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars.

31

-

-

... More
Flexible Polymer Detection Tube with all necessary fittings & supports of 06mm UL Listed

814

-

-

... More
Supply, insatlation, testing and commissioning Health Monitoring Alarm Panel to complete the system.

31

-

-

... More
PART-J : SOLAR WATER SYSTEM

-

-

-

... More
Supply, insatlation, testing and commissioning of 500LPD FPC solar water heating system, with 2.0mm SS Inner Tank and GI Pre Coated Outer Cladding after 50mm PUF Insulation and with provision of 2x2KW Electrical Heater. The tank stand of MS Hot Dip Galvanised frame of suiltable size. With 4Nos. Flat Plate Collector shall be copper based - with copper tubes and copper fins as per MNRE specification and as per IS12933. Collector approx size 2080mmx1070mmx100mm each (100 litres/day capacity). Complete with suitable MS Powder Coated Stand. Including Non Return Valve, Three Gate Valve for Tank and Collector, Temperature Gauge, System Internal Piping and Air Vent of system with height as per cold water tank.Excluding minimum civil work of grouting for 500LPD FPC solar water heating system with electrical back-up.

1

-

-

... More
Supply, insatlation, testing and commissioning of 700LPD FPC solar water heating system, with 2.0mm SS Inner Tank and GI Pre Coated Outer Cladding after 50mm PUF Insulation and with provision of 2x2KW Electrical Heater. The tank stand of MS Hot Dip Galvanised frame of suiltable size. With 6Nos. Flat Plate Collector shall be copper based - with copper tubes and copper fins as per MNRE specification and as per IS12933. Collector approx size 2080mmx1070mmx100mm each (100 litres/day capacity). Complete with suitable MS Powder Coated Stand. Including Non Return Valve, Three Gate Valve for Tank and Collector, Temperature Gauge, System Internal Piping and Air Vent of system with height as per cold water tank.Excluding minimum civil work of grouting for 700LPD FPC solar water heating system

12

-

-

... More
Supply, insatlation, testing and commissioning of 800LPD FPC solar water heating system, with 2.0mm SS Inner Tank and GI Pre Coated Outer Cladding after 50mm PUF Insulation and with provision of 2x3KW Electrical Heater. The tank stand of MS Hot Dip Galvanised frame of suiltable size. With 7Nos. Flat Plate collector. The Collector shall be copper based - with copper tubes and copper fins as per MNRE specification and as per IS12933. Collector approx size 2080mmx1070mmx100mm each (100 litres/day capacity). Complete with suitable MS Powder Coated Stand. Including Non Return Valve, Three Gate Valve for Tank and Collector, Temperature Gauge, System Internal Piping and Air Vent of system with height as per cold water tank.Excluding minimum civil work of grouting for 800LPD FPC solar water heating system

9

-

-

... More
PART-K : INTERNAL & EXTERNAL FIRE FIGHTING SYSTEM

-

-

-

... More
Supply, insatlation, testing & commissioning of electric driven main fire Hydrant & Sprinkler pumps suitable for automatic operation complete in all respect as required & as per enclosed specification & consisting of the following: Horizontal type multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, to ensure minimum pressure of 3.5 kg/cm2 at highest and farthest outlet at specified flow of 2280 LPM & 100 m head conforming to IS:1520 complete with mechanical seals, safety relief valve, pressure gauges on delivery side, drain and bypass arrangement for testing of pump complete. Suitable HP Squirrel cage Induction motor suitable for operation on +/- 5 % of 415V, 3 phase, 50Hz, AC supply for the above pump rating with synchronous speed of 1500 RPM, IE-3, TEFC type confirming to IS-325 with IP:55 protection for enclosure, horizontal foot mounted with class F insulation, flexible coupling & coupling guard with the pump complete.Common bed plate fabricated from MS channel / ISMB with spring type vibration isolators. The pump set base shall be held by bolts grouted in the suitable cement concrete foundation duly plastered & painted including foundation bolts, washers complete etc. as required.

4

-

-

... More
Supply, insatlation, testing & commissioning of Diesel engine driven standby fire pump suitable for automatic operation complete in all respect as required & as per enclosed specification & consisting of the following:Horizontal type multistage, centrifugal, split casing pump of cast iron body & bronze impeller with SS shaft, to ensure minimum pressure of 3.5 Kg/Sqcm at the highest & farthest outlet at a flow 2280 LPM & 100 m head confirming to IS:1520 with mechanical seals, safety relief valve, pressure gauges on delivery side, drain & bypass arrangement for testing of pump complete.Radiator Water cooled diesel engine developing required BHP at 1500 RPM for the pump, flexible coupling & coupling guard with the pump & common bed plate for mounting of engine & pump shall confirming to relevant BS/IS standard with auto starting mehanism.The common base frame shall be held by bolts grouted in the concrete including foundation bolts, washers as required, vibration damping arrangement by cushy foot, engine panel with battery charger provided by engine manufacturer, connection to engine starting panel, SMF batteries as per OEM recommendation, 180AH with casing, lugs, stand & terminations to diesel engine, charger complete. Exhaust pipe of required length ( discharge to leave above roof level as per standard) with 50mm thick glasswool pipe section, covered with aluminum cladding, residential silencer muffler, instruments & protection-stop solenoid for auto stop in the event of fault with auto indications, day oil tank of 200 ltrs.with first charge of diesel fabricated out of 4mm MS sheet with inlet/ outlet ON/OFF valves, level indicator, drain pipe, 15mm dia MS fuel line complete . Common bed plate of fabricated MS channel / ISMB with vibration isolator. The base frame shall be held by bolts grouted in the suitable cement concrete foundation duly plastered and painted including foundation bolts, washers complete etc. as required.

2

-

-

... More
Supply, insatlation, testing and Commissioning of electric driven Pressurization/Jockey Pump suitable for automatic opertation complete as required & as as per enclosed specification and consisting of the following: Horizontal type end suction centrifugal,Jockey pump of cast iron body and bronze impeller, with SS shaft, to ensure at highest and farthest outlet at a flow of 180 LPM & 100 m head confirming to IS-1520 complete with necessary safety relief valve, drain, pressure gauge on the delivery side , drain and bypass arrangement for testing of the working of the pumping set as required. Suitable HP Squirrel cage induction motor suitable for operation on +/- 5 % of 415 V, 3 phase,50Hz, AC supply for the above pump with synchronous speed of 3000 RPM, IE-3, T.E.F.C. type confirming to IS - 325 with IP:55 protection for enclosure, horizontal foot mounted, class-F insulation, flexible coupling & coupling guard with the pump complete. Common base frame shall be fabricated from MS channel / ISMB with vibration isolator. The base frame shall be held by bolts grouted in the suitable cement concrete foundation duly plastered and painted including foundation bolts, washers complete etc. as required.

4

-

-

... More
Supply, installation, testing and commissioning of Electric driven water Curtain pump suitable for automatic operation and consisting of following: complete in all respect as required as per specifications. a) Horizontal type,multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm.at highest and farthest outlet at specified flow of 2280 LPM at minimum 100 M head conforming to IS 1520. b) Suitable HP squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on +/- 5 % of 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS- 325. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. duly painted as required. d) Suitable cement concrete foundation duly plastered with anti vibration pads.

1

-

-

... More
Providing and fixing horizontal centrifugal end suction single/multi stage, single/multi outlet pumping set with bronze impeller with C.I. body and connected by a flexible coupling to a totally enclosed fan cooled induction motor mounted on a common structural base plates with all pump accessories complete as per specifications including pressure gauges with gunmetal isolation valves and anti vibration pad, motor to be suitable for +/- 5% 415 volts, 3 phase, 50 cycles A.C. supply (Specifications as per fire fighting requirements and on the pattern of TAC or local authority approval) as per instruction and following specifications: (All pumps shall have mechanical seal). Fire Terrace Pump for Sprot Complex Type : End suction Speed (rpm) : 2900 Capacity : 450 lpm Head : 35Mtr. App. H.P. : 5

1

-

-

... More
ELECTRICAL SYSTEM Supply, installation, testing and commissioning of the fire pump control panel, front operated cubicle construction, Floor mounted type, fabricated out of 2mm thick CRCA Sheet, Compartmentalized with hinged lockable doors, dust and vermin proof, Powder coated of approved shade after 7 tank treatment, Cable alley, inter-connections, having Switch gear and accessories mounting, internal wiring, earth terminals, Top/ Bottom cable entry, numberings etc. suitable for operation of 415 volts, 3 phase 4 wire 50 Hz AC Supply with enclosure protection class IP 42 complete as required and as as per enclosed specification with the following: INCOMER - 2No. - 800 Amps, Four pole, 50 KA MCCB with rotary handle on door. - Digital Voltmeter (0-500 Volts) with selector Switch & protected by MCB. - Digital Ammeter (0-800 Amps) with selector Switch & CT's etc. - Set of (R,Y,B) LED phase and ON / OFF indication Lamps protected by MCB. Buscoupler 1 No. 800 Amp 4P MCCB (Icu=Ics value 50KA) . 1 Set of ON/ OFF LED type indication lamp controlled by 2 Amp SP MCB. Including all features of mechnical interlocking with incomers. BUSBAR - 1 Set of 1000 Amps 4P Aluminium OUT GOINGS For 2no. hydrant Pump and 2No. Sprinkler Pump -Total 4 Nos. - 200 Amps. 4P MCCB ( Motor Duty) 35 KA with rotary handle on door. - Digital Ammeter (0-200 Amps) with selector Switch & CT's etc. - Set of ON / OFF indication Lamps protected by MCB. - Suitable 70HP fully automatic Star delta starter with over load protection & current sensing type single phase preventor complete with all accessories and internal wiring for automatic operation.

1

-

-

... More
- Set of Selector switches for Auto / Manual /OFF operation. - Set of ON & OFF Push Buttons For Water curtain pump -1 Nos. - 200 Amps. 4P MCCB ( Motor Duty) 35 KA with rotary handle on door. - Digital Ammeter (0-200Amps) with selector Switch & CT's etc. - Set of ON / OFF indication Lamps protected by MCB. - Suitable 70HP fully automatic Star delta starter with over load protection & current sensing type single phase preventor complete with all accessories and internal wiring for automatic operation- Set of Selector switches for Auto / Manual /OFF operation. - Set of ON & OFF Push Buttons. For Jockey pumps -4 No. - 63 Amps.4P MCCB, 35 KA (motor duty) with rotary handle on door. - Digital Ammeter (0-60 Amps) with selector Switch & CT's etc. - Set of LED ON / OFF indication Lamps protected by MCB. - Suitable 10HP fully automatic DOL starter with over load protection & current sensing type single phase preventor complete with all accessories internal wiring for automatic operation. - Set of Selector switches for Auto / Manual / OFF operation. - Set of ON & OFF Push Buttons. SYSTEM CONTROLLER ( System controller for complete fire fighting systems i/c water level controls) Designing, supply, Installation, Testing and Commissioning of PLC based system controller to control operation of Main Electric fire Pumps ,Diesel Pump & Jockey pumps in sequence as per specification consisting of relays, timers, sensors, annunciation window for fault indications with 30minutes backup power with SMF battery and battery charger complete as required. Casting of 300mm high PCC pedestal duly painted for above panel.

-

-

-

... More
NOTE : 1. All MCCB shall have 100% Ics =Icu 2. Low water level indication in fire tank should be interlocked with centralized PLC control panel.

-

-

-

... More
Providing, fixing, testing and commissioning of control panel for Terrace Booster pumps . Incoming: MCCB 40A 1 set of Phase indicating lamps, 1 set of 40A Al bus bars, 1No Ammeter, 1No Voltmeter with phase selector switch Feeder for Booster Pumps - 1 No. 1 No. 32A TP MCCB without releases, DOL starter with over load relay, single phase preventor and indicating lamps with ON/OFF push buttons. 1 No. Automanual selector switch. Suitable for booster pumps.

1

-

-

... More
Providing and fixing 4 way Gun-metal Fire Brigade inlet connection comprising of 4 nos. 63mm dia. male instantaneous inlet couplings with cap and chain as required for 150mm dia. flanged conforming to IS- 904 complete (to be connected to static tank) as required and as per enclosed specification.

1

-

-

... More
Providing and fixing fire brigade suction hose coupling (draw out connection) with nut for female coupling as per IS-902 complete with 150mm dia. Suction pipe and foot valve (to be connected to static tank) complete as required and as per enclosed specification.

1

-

-

... More
Supply, Installation, testing and commissioning of pressure switches in MS pipe for Hydrant Electric pump, diaphragm type, adjustable range from 0-10 kg/sq.cm and a regulation range of 0.1 - 1.5 kg/sq.cm direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS-316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications.

8

-

-

... More
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

4

-

-

... More
Supplying & fixing Internal and External gun metal single headed fire hydrant landing valve with instantaneous Gun metal coupling of 63mm dia with cast iron wheel ISI marked conforming to IS:5290(Type-A) with blank PVC cap and chain as required.

224

-

-

... More
Providing & fixing 63 mm dia gum metal short Branch pipe with 20mm (nominal internal diameter) in size stainless steel nozzle conforming to IS:903 suitable for instantaneous connection complete to inter-connect hose pipe, coupling etc. as required and as per enclosed specification.

221

-

-

... More
Providing & fixing 63mm dia., 15mtr. long RRL hose pipe (ISI Marked) with 63mm dia. male and female gun metal couplings duly binded with GI wire, rivets etc. conforming to IS- 636 (Type-A) complete as required & as per enclosed specification.

441

-

-

... More
Providing and fixing First-Aid Hose Reel 20mm dia. x 30m long (minimum length) (Thermoplastic Type as per I.S. 12585) complete with drum, bracket, 25mm dia. shut-off valve and 5mm Gun-Metal nozzle conforming to IS-:884, connection with riser with MS C- class pipe, painting the MS works complete as required & as per enclosed specification.

223

-

-

... More
Providing and fixing angle iron (40mmx40mmx5mm) door frame and S.S.sheet (2mm thick) cum glass shutter of size 2.1mtrx0.9mtr(N.S.) with 25mmx25mmx3mm angle frame all around and stiffened in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamel paint i/c sign writing on glass at internal hydrant including providing & fixing S.S. sheet 2mm thick on remaining portion above door to close opening i/c painting etc. as required. Glass shall be 6 mm thick.

220

-

-

... More
Providing and fixing 2 way Gun-metal Fire Brigade inlet connection comprising of 2 nos. 63mm dia. male instantaneous inlet couplings with cap and chain as required for 100mm dia. flanged conforming to IS- 904 complete (to be connected to dawon comer) as required and as per enclosed specification.

2

-

-

... More
Supplying and fixing orifice plate made of 6 mm. thick stainless steel with orifice of required size in between flange & landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 kg/cm2 complete as required & as per enclosed specification.

62

-

-

... More
PIPES & VALVES Supplying, fixing, testing and commissioning of pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted and buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. a)150mm dia. (for External)

3000

-

-

... More
Providing, fixing, jointing & commissioning of following sizes of C- class heavy duty Mild Steel pipes conforming to IS:1239/ IS-3589, including cutting, welding, nut-bolts, gasket, fitting viz. bends, tees, reducers, crosses, flanges etc. & fixing the pipes on wall / ceiling / beam / floor with suitable MS clamps / structural supports/PCC block and painting complete as required and as per enclosed specification. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 & pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. & from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.

-

-

-

... More
(a) 250mm dia.

30

-

-

... More
(b) 200mm dia.

15

-

-

... More
(c) 150 mm dia.

2295

-

-

... More
(d) 100 mm dia.

367

-

-

... More
(e) 80 mm dia.

340

-

-

... More
(f) 65 mm dia.

1258

-

-

... More
(g) 50mm dia.

804

-

-

... More
(h) 40 mm dia.

283

-

-

... More
(j) 32 mm dia.

543

-

-

... More
(k) 25 mm dia.

5210

-

-

... More
Providing & fixing of following sizes of butterfly valve of rating PN 16, wafer type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft, conforming to IS-13095 of the following sizes complete with cast iron hand lever companion flanges, bolts, nuts, washers & inserted rubber gaskets, as required and as per enclosed specification.

-

-

-

... More
(a) 250mm dia.

2

-

-

... More
(b) 200mm dia.

2

-

-

... More
(c) 150 mm dia.

34

-

-

... More
(d) 100 mm dia.

6

-

-

... More
(e) 80 mm dia.

8

-

-

... More
(f) 65 mm dia.

10

-

-

... More
Providing & fixing of following sizes of CI non return valve conforming to API-594 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required and as per enclosed specification.

-

-

-

... More
(a) 250mm dia.

2

-

-

... More
(b) 150 mm dia.

10

-

-

... More
(c) 100 mm dia.

2

-

-

... More
(d) 80 mm dia.

2

-

-

... More
Providing & fixing of CI double flange sluice valve of rating PN 1.6 with non rising SS spindle, Bronze/Gun Metal seat confirming to IS -780 complete with flanges,nut-bolts, gasket, washers etc. as required and as per enclosed specification. a) 150mm dia.

4

-

-

... More
Providing and fixing gunmetal gate valve with PN 16 rating with nut, bolts & washers, painting etc complete as required as per specifications.

-

-

-

... More
(a 25 mm nominal bore

223

-

-

... More
(b) 50 mm nominal bore

21

-

-

... More
Providing & fixing of Stainless Steel double flange suction " Y" type strainer fabricated out of minimum 1.2 mm thick Stainless Steel sheet with 3 mm dia. perforation holes including nuts, bolts and 3 mm thick rubber insertion complete & tested to 20 Kg/Sq.cm pressure complete as required and as per enclosed specification.

-

-

-

... More
(a) 150 mm dia.

7

-

-

... More
(b) 100 mm dia.

1

-

-

... More
(c) 80 mm dia.

5

-

-

... More
Providing & fixing of 25mm dia. gunmetal air release valve with all fittings and forged ball valve on header complete as required and as per enclosed specification.

12

-

-

... More
Providing and fixing following size Pressure gauge (0-15 Kg/Cm2) complete with shut off valve duly calibrated before installation complete as required & as per enclosed specification. 150mm dia.

222

-

-

... More
Providing & fixing of installation control valve (Sprinkler Alarm Valve) of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases ,strainer, pressure switch, cock valve complete with drain valve and bypass, test control box,ball valves, flanges, orifice plate, fittings, gasket etc.suitable for 150 mm diameter pipe size complete as required as per enclosed specification.

3

-

-

... More
Air pressure vessel for Fire Pump :- Providing and fixing double flanged vertical air vessel fabricated from 6mm M.S. plate with dished ends from 8mm M.S. plate, outside with one coat of primer and two coats of synthetic enamel paint of approved shade, complete with pressure gauges and all other required accessories to operate commonly main fire pump, Diesel Fire pumps and Jockey pumps at drop of pressure automatically at required pressure setting complete as required and as per enclosed specification. For Fire Pump: Dia. : 450mm Height of shell : 2000mm Working pressure :12 Kg/Sq.cm Test Pressure : 16 Kg/Sq.cm

2

-

-

... More
For Water Curtain Pump: Dia. : 450mm Height of shell : 2000mm Working pressure :8 Kg/Sq.cm Test Pressure : 12 Kg/Sq.cm

2

-

-

... More
Providing and fixing reinforced neoprene rubber vibration eliminators/expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2 pressure, complete as per specification.

-

-

-

... More
(a) 150mm dia.

12

-

-

... More
(b) 100 mm dia.

2

-

-

... More
(c) 80mm dia.

8

-

-

... More
Providing, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection & drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS:4736-1968.

12

-

-

... More
Supply, installation, testing and commissioning of 150 mm dia Zonal Control Valve inclusive of 1 No. 150 mm dia butterfly valve, 150mm diam, Flow Switch, water pressure gauges & 25 mm dia. Auxillary Drain valve with supervisory switch with sight glass with necessary MS / GI piping with threaded fittings of required sizes complete as required.

14

-

-

... More
Providing, fixing, testing and commissioning of Deluge Valve with Electrical operated Trim Set with solenoid valve and switches, Gong valve, Drain valve, Test assembly, 100 mm dia isolation valve with bypass including actuation & control panel, control cable from deluge valve to solenoid switch 2 Core x 1.5 Sq. mm., UL Listed / FM Approved, complete with drain cock arrangement and with all accessories, welded or screwed as required including cutting holes and chases in brick or RCC walls and making good complete as per approved model.

6

-

-

... More
Providing and fixing modular construction annunciation panel for flow control switches having 3 zones , (3 working & 1 spare for future) complete in all respect and consisting of; Fault indication for each zone Fire/fault hooter. Alarm panel for fire/fault Battery for emergency Battery Charger Mains supply

7

-

-

... More
Providing and fixing heavy duty copper armored cables 1.1 KVA grade including necessary support clamps at ceiling level and connection legs complete in all respects. a) Control cable 4 core 1.5 Sq.mm

300

-

-

... More
AUTOMATIC SPRINKLER SYSTEM

-

-

-

... More
Providing & fixing of 15 mm dia. sprinkler head with standard response Quartzoid Bulb operate at 68 degree C complete with all accessories as required and as per enclosed specification (UL Listed) Upright & Pendant type in chrome finish (Standard Coverage)

2471

-

-

... More
Providing & fixing brass quartzoid sprinklers (UL, FM approved) of 15 mm dia size, suitable for sustaining the seat & water hammer effect. The type & temperature rating shall be as follows Sidewell extended coverage (68 deg.C) sprinkler quick response type as per specifications

104

-

-

... More
Providing & fixing flexible tubes in corrugated SS, for connecting pendant sprinklers to branch lines complete with all necessary accessories, reducers, O-rings, nipples etc., supporting structural arrangments in the false ceiling/slab as per site requirement for the below lengths and tested for min 15 Kg/Sq. cm pressure with G.I. retainer rings & guide bolts complete as required & as per enclosed specification (UL Listed) For 1500 mm length

62

-

-

... More
Providing, fixing, testing and commissioning of 15 mm dia NB, Brass Water Curtain Nozzle, suitable for a maximum working pressure of 12.3 kg / cm2 (175 PSI) with K Factor of 23, suitable for mounting in the horizontal position complete as per approved model & instructions of the Engineer-In-Charge.

99

-

-

... More
FIRE EXTINGUISHER

-

-

-

... More
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension braket as required as per specifications.

282

-

-

... More
Supply, installation, testing and commissioning ISI marked (IS:15683) portable fire extinguisher, water (gas pressure) type capacity 9 ltr. with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specifications.

2

-

-

... More
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications.

282

-

-

... More
Providing and fixing Clean Agent Modular (ceiling mounted) Type Capacity 5 Kg CE certified Fire Extinguisher filled with HFC 236FAClean Agent Gas. Complete in all respect.

6

-

-

... More
Providing and fixing CO2 type fire extinguishers consisting of welded M.S. cylindrical body automatic modular CO2 type extinguisher actuated through a sprinkler head mounted on The extinguisher body finished externally with red enamel paint & fixed to ceiling with brackets complete with internal charge. (Capacity 22.5 Kg.)

1

-

-

... More
PART-L : BIO-DEGRADABLE AUTOMATIC COMPOSTER

-

-

-

... More
Supply, installation, testing and commissioning of Bio-Degradable Automatic composting machine at the specific location in complex having capacity 1200 kg per day with inbuilt shredder Make: GEM INDIA, GO WASTE, BRISANZIA, SOLARUMPIRE for converting Bio-degradable material into compost for using the same as manure for Horticulture purpose as per the relevant terms & conditions and the direction of Engineer-in-charge. As per technical specifications,Payment will be made after successful Installation and commissioning of the machine. Any repair or damage caused due to running of machine or due to any other reason will be made good/repaired/ replacement of part by the agency free of cost for which no extra payment will be made for one year after installation.

1

-

-

... More
Supply of Trolley of SS-304 size- 24x30 inch with whilearrangement for smooth mobility.

5

-

-

... More
Operation and maintenance of the Bio-Degradable Automatic Composting along with the operator and 4 No. Assistants for operation and maintenance of all components of the machine. The item include daily segregating the waste into Bio-degradable organic and non- bio-degradable with personal protection equipment viz Gloves, Uniform, Disposable mask, Gumboots, Mat, Wiper, Plastic bags etc. and the chemicals for cleaning like phenyl bottles, brooms, wiping cloth, duster etc. as per the direction of the Engineer-in charge.

12

-

-

... More
PART-M : EXTERNAL ELECTRICAL WORKS

-

-

-

... More
11KV H.T. PANELS

-

-

-

... More
11kV 3 HT Panel Board. (In Indoor Cubical) Design, Manufacture, Supply at site, inspection of Consultant's/client at Factory at your cost of 11KV, 50Hz, In extensible type Indoor Cubical (IP: 42 As per IS 3427:1969/IEC 298), free standing metal clad vaccum circuit breaker HT switchgear including suitable raiting protection relays, indications, push buttons, copper busbars, Door earthed, Handle For breaker Spring Charging, etc. as per the requirement detailed in BOQ / SLD etc. complete as required. The Panel shall be fabricated with CRCA sheet steel enclosure used for Side Sheet, Partition, removable Top/Bottom, Doors Sheet 2mm and 3mm Removable Gland Plate & Base Frame. The Panel Shall be electro static powder coating paint (80-100 micron) with RAL 7035 Shade . (Similar to Schneider- Model No. PIX 12 or equivalent). Incomings 1 Nos. as detailed below 630A, 11kV, 18.4kA for 3Sec., TP Electrically operated horizontal draw type Vacuum cicuit braker with, Auxilary contact minimum 4NO+4NC, 240V AC manual spring charge motor, trip free, dust & vermin proof, 24V DC Closing & Tripping Coil, Safety Shutter. Confirming to IEC 62271-100. (Similar to Schneider-Model No HVX TROLLEY or equivalent)

-

-

-

... More
Current Transformer - 3Nos. Epoxy resin cast double wound Single Phase CT for below total specified KVA Transformers. BIL : 28RMS/75KVP Core-1 :15 VA, Class 0.5 For Metering and Core- 2:15 VA, Class- 5P10 For protection. CT Ratio. 110Volts Tri-Vector Meter with Import/Export, Demand & RS485 Port Similar to Enersol make Model Number TVMR 5105 Class 0.5. IDMT self power relay with 3 elements for over current (50-200%) and 1 element for earth fault protection (10-40%) CDG-31 type. Anti pumping relay-VAA11, Master Trip relay-VAJH 13, Trip circuit supervision relay & Non Communicable Numercial relay for 50/ 51/ 50N/ 51N. Potential transformers- 3Nos. Single Phase, Epoxy resin cast drawout type, PT Ratio 11KV / (Root 3) /110VAC / (Root 3) ratio class 0.5 accuracy, 100 VA burden, feeder connected HV fuse on primary side and MCB on secondary side. A set of breaker R, Y, B phase indication LED lamps with control Fuse/MCB Emergency trip push button Limit switches with 2NO + 2NC breaker auxiliary contacts Control:- T-N-C ( Trip, Neutral, Close ) breaker control switch with indication arrangement.

-

-

-

... More
BUS BARS 1000A TP Copper Bus-Bar + 30 x 6 Copper (Earth) OUTGOING- 2 Nos VCB as detailed below 630A, 11kV, 18.4kA for 3Sec., TP Electrically operated horizontal draw type Vacuum cicuit braker with, Auxilary contact minimum 4NO+4NC, 240V AC spring charge motor, trip free, dust & vermin proof, 24V DC Closing & Tripping Coil, Safety Shutter. Confirming to IEC 62271-100. (Similar to Schneider-Model No HVX TROLLEY or equivalent) Current Transformer - 1Set with each incomer of 3Nos. Epoxy resin cast double wound Single Phase CT for above each specified KVA Transformers. BIL : 28RMS/75KVP Core-1 :15 VA, Class 0.5 For Metering and Core- 2:15 VA, Class- 5P10 For protection. CT Ratio 110Volts Multi-Functional Meter Similar to Enersol make Model Number MF 4805 Class 0.5. IDMT self power relay with 3 elements for over current (50-200%) and 1 element for earth fault protection (10-40%) CDG-31 type. Anti pumping relay-VAA11, Master Trip relay-VAJH 13, Trip circuit supervision relay & Non Communicable Numercial relay for 50/ 51/ 50N/ 51N. 3 Nos. Auxiliary relays for transformer faults WTI, OTI and Bucholz Relay. 8 window annunciator with hooter (2 Window for over Current & Earth fault) (2 Window for OTI alarm & Trip) (2 Window for WTI alarm & Trip) (2 Window Bucholz alarm & Trip) Emergency trip push button Limit switches with 2NO + 2NC breaker auxiliary contacts Control:- T-N-C ( Trip, Neutral, Close ) breaker control switch with indication arrangement.

-

-

-

... More
GENERAL COMMON FOR WHOLE PANEL Power Pack Input - 110 V AC, Output-24V DC with 02 Nos. 12 Volts 100AH Maintenance Free Battery and charger unit, Capacitor Bank for emergency for TRIP System complete with suitable capacity of Ammeter & Voltage meter I/C Connections with minimum 2.5 Sqmm FRLS Copper conductor wires All control wiring with protection & test terminal block as required. The Control wiring sizes- 2.5 Sqmm, for Phases + Neutral + DC Control circuit + CT wire and PT Wire 1.5 Sqmm & Earth 4.0 Sqmm Cu Flexible. TVSS 6 Mode with Fuse protection A set of breaker ON / OFF / Trip / DC control supply / Trip circuit healthy / Spring Charged with control fuse/MCB. 100 Watts Strip heater, auxilary Supply - 110 Volts AC with thermostat range - minimum 02 - 105 Degree celsius Stem type for moisture absorption. Suitable for connection to 3C x 240sq.mm. Cross linked polythelene(XLPE) 11kV cables or as called for. Danger Plate, LED bulb with holder connected to a toggle switch for each door open. a) 11kV 3 HT Panel Board. (In Indoor Cubical) - As described above.

1

-

-

... More
11kV 6 HT Panel Board. (In Indoor Cubical) Design, Manufacture, Supply at site, inspection of Consultant's/client at Factory at your cost of 11KV, 50Hz, In extensible type Indoor Cubical (IP: 42 As per IS: 3427:1969/IEC 298), free standing metal clad vaccum circuit breaker HT switchgear including suitable raiting protection relays, indications, push buttons, copper busbars, Door earthed, Handle For breaker Spring Charging, etc. as per the requirement detailed in BOQ / SLD etc. complete as required. The Panel shall be fabricated with CRCA sheet steel enclosure used for Side Sheet, Partition, removable Top/Bottom, Doors Sheet 2mm and 3mm Removable Gland Plate & Base Frame. The Panel Shall be electro static powder coating paint (80-100 micron) with RAL 7035 Shade . (Similar to Schneider- Model No. PIX 12 or equivalent). Incomings 2 Nos. as detailed below 630A, 11kV, 18.4kA for 3 Sec., TP Electrically operated horizontal draw type Vacuum cicuit braker with, Auxilary contact minimum 4NO+4NC, 240V AC spring charge motor, trip free, dust & vermin proof, 24V DC Closing & Tripping Coil, Safety Shutter. Confirming to IEC 62271-100. (Similar to Schneider-Model No HVX TROLLEY or equivalent) Current Transformer - 3Nos. Epoxy resin cast double wound Single Phase CT for below total specified KVA Transformers. BIL : 28RMS/75KVP Core-1 :15 VA, Class 0.5 For Metering and Core- 2:15 VA, Class- 5P10 For protection. CT Ratio. 110Volts Tri-Vector Meter with Import/Export, Demand & RS485 Port Similar to Enersol make Model Number TVMR 5105 Class 0.5. IDMT self power relay with 3 elements for over current (50-200%) and 1 element for earth fault protection (10-40%) CDG-31 type. Anti pumping relay-VAA11, Master Trip relay-VAJH 13, Trip circuit supervision relay & Non Communicable Numercial relay for 50/ 51/ 50N/ 51N.

-

-

-

... More
Potential transformers- 3Nos. Single Phase, Epoxy resin cast drawout type, PT Ratio 11KV / (Root 3) /110VAC / (Root 3) ratio class 0.5 accuracy, 100 VA burden, feeder connected HV fuse on primary side and MCB on secondary side. A set of breaker R, Y, B phase indication LED lamps with control Fuse/MCB. Emergency trip push button Limit switches with 2NO + 2NC breaker auxiliary contacts. Control:- T-N-C ( Trip, Neutral, Close ) breaker control switch with indication arrangement. BUS BARS 1000A TP Copper Bus-Bar + 30 x 6 Copper (Earth) OUTGOING- 3 Nos VCB & 1 No Bus coupler as detailed below 630A, 11kV, 18.4kA for 3Sec., TP Electrically operated horizontal draw type Vacuum cicuit braker with, Auxilary contact minimum 4NO+4NC, 240V AC spring charge motor, trip free, dust & vermin proof, 24V DC Closing & Tripping Coil, Safety Shutter. Confirming to IEC 62271-100. (Similar to Schneider-Model No HVX TROLLEY or equivalent) Current Transformer - 1Set with each incomer of 3Nos. Epoxy resin cast double wound Single Phase CT for above each specified KVA Transformers. BIL : 28RMS/75KVP Core-1 :15 VA, Class 0.5 For Metering and Core- 2:15 VA, Class- 5P10 For protection. CT Ratio 110Volts Multi-Functional Meter Similar to Enersol make Model Number MF 4805 Class 0.5. IDMT self power relay with 3 elements for over current (50-200%) and 1 element for earth fault protection (10-40%) CDG-31 type. Anti pumping relay-VAA11, Master Trip relay-VAJH 13, Trip circuit supervision relay & Non Communicable Numercial relay for 50/ 51/ 50N/ 51N

-

-

-

... More
3 Nos. Auxiliary relays for transformer faults WTI, OTI and Bucholz Relay. 8 window annunciator with hooter (2 Window for over Current & Earth fault) (2 Window for OTI alarm & Trip) (2 Window for WTI alarm & Trip) (2 Window Bucholz alarm & Trip) Emergency trip push button Limit switches with 2NO + 2NC breaker auxiliary contacts Control:- T-N-C ( Trip, Neutral, Close ) breaker control switch with indication arrangement. GENERAL COMMON FOR WHOLE PANEL Power Pack Input - 110 V AC, Output-24V DC with 02 Nos. 12 Volts 100AH Maintenance Free Battery and charger unit, Capacitor Bank for emergency for TRIP System complete with suitable capacity of Ammeter & Voltage meter I/C Connections with minimum 2.5 Sqmm FRLS Copper conductor wires. All control wiring with protection & test terminal block as required. The Control wiring sizes- 2.5 Sqmm, for Phases + Neutral + DC Control circuit + CT wire and PT Wire 1.5 Sqmm & Earth 4.0 Sqmm Cu Flexible.

-

-

-

... More
TVSS 6 Mode with Fuse protection A set of breaker ON / OFF / Trip / DC control supply / Trip circuit healthy / Spring Charged with control fuse/MCB. 100 Watts Strip heater, auxilary Supply - 110 Volts AC with thermostat range - minimum 02 - 105 Degree celsius Stem type for moisture absorption. Suitable for connection to 3C x 240sq.mm. Cross linked polythelene(XLPE) 11kV cables or as called for. Danger Plate, LED bulb with holder connected to a toggle switch for each door open a) 11kV 6 HT Panel Board. (In Indoor Cubical) - As decsribed above.

1

-

-

... More
COMPACT SUB-STATION 630kVA COMPACT SUB-STATION WITH CAPACITOR PANEL (FOR OR- BLOCK-3 & 4 & JCO BLOCK) Design, Manufacture, Supply at site, loading and unloading shifting, installation, testing and commissioning of compact sub-station consisting of 2IN LBS 1 VCB OUT, Transformer, capacitor and L.T. Panel as described below. HT SWITCHGEAR (H.V. COMPARTMENT) 11kV 630Amps 18.3KA for 3 Sec. SF6 insulated Non-Extinsible Compact RMU consisting of Incomer- 2 x Load break switch and Outgoing- 1 x Fixed Manual Vacuum Circuit Breaker each VCB with self powered microprocessor based numerical 3 over current and Earth Fault (IDMT+Inst.) relay in SF6 insulated stainless steel enclosure, with series trip for protection & metering. Interconnection between HT switchgear and transformer shall be with copper unarmorured XLPE 11kV H.T. Cable suitable for minimum 18.3kA for 3Sec. Relay should be capable of OTI/ WTI protection along with over current and Earth Fault. Provide 6 window annunciator with alarm and trip & hooter, 2 Window for over Current & Earth fault, 2 Window for OTI alarm & Trip & 2 Window for WTI alarm & Trip. INTERCONNECTION AND EARTHING Interconnection Between HT switchgear & Transformer using 1Cx3x95Sq.mm XLPE Single core Copper cable & Interconnection between Transformer & LT switchgear using 1000A TPN Copper Busbars. Internal earthing connections by using 32x6 mm GI strips.

-

-

-

... More
TRANSFORMER COMPARTMENT 630KVA 11KV/433V Dyn11 Oil filled hermatically sealed copper wound transformer, Corruagated/PSR Radiators & Top normal porcelein Bushings for HT & LT with Off load tap switch of rating +5% to -10% @2.5%. Class 'A' of Thermal insulation, Suitable for Maximum Ambient temperature 45º C and maximum winding temperature 105 deg cel (Make:- Same make of CSS) Losses standard with IS tol. Losses as per IS:1180 Level-3, BEE star 2 rating, & IS:2026 all parts latest as on date whichever is higher, Oil Temperature Indicator with Alarm and Trip contact + Winding Temperature Indicator with Alarm and Trip Contact including Manufacturer's BEE Certifications. L.V. COMPARTMENT INCOMER FROM TRANSFORMER 1 No. 1000Amps 4P Fixed type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS:1397-2 (1993) & complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Cable connections on incomer side and bus bar connection at output sides. RELAYs, METERING INDICATOR & CT's 1 No. 30-3000mA 11kV ELR with CBCT with outgoing from VCB and 3Nos. 30-3000mA 1.1kV ELR with CBCT with outgoing from Transformer as shown in SLD. Provide 3Nos indicating lamps on each MCCB for status indication "ON","OFF" , and trip due to earth leakage for all outgoing.

-

-

-

... More
1 Nos. Independent manual spring closing mechanism Provide seprate 3Nos. CTs, Class-0.5, in each transformer Incoming bus section for capacitor panel APFCR. Provide 4Nos indicating lamps on each ACB for status indication "ON","OFF", tripped due to fault and trip circuit health for all ACB CT-Operated Trinity Make- Globin or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, Harmonics, Memory 2MB, HT/LT selectable, USB port, RS-485 Port, LCD display , 4 relay output for all incomers with class - 0.5 accuracy. CT-Operated Trinity Make- Power Pro or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Max. Demand, RS-485 Port, LCD display for all outgoings except outgoing for capacitor with class - 0.5 accuracy. BUSBARS SECTIONS 1200Amps TP+N, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar.

-

-

-

... More
Each Bus Section with 1 No Surge protection device Type 1 ( Class B),true status indication, 7 Mode, spark gap type suitable for 10/ 350µs surge,Voltage Protection level Up 4.0kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral & 3Nos. phase to earth and 1Nos. neutral to earth with discharge Current Imax. ≥ 50KA Per mode & In ≥ 25kA per Mode. Make & Model: Argos-AG-415-40T1-E or eq. SPD with 125A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 16sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. OUTGOINGs 1 No. 1000Amps TP+Neutral link EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS:1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side & bus bar connection at output sides. 1 Nos. 250A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended

-

-

-

... More
CAPACITOR COMPARTMENT The capacitor banks in tier formation, Each capacitors specifications shall be MPP heavy duty cylindrical construction capacitors, 415Volts, 50 hz, Temp. Class-'C', Temp. of Air Surrounding the Capacitor - Max for 24hour- 45 deg. centigrade , Max. for a year 35 deg. Centigrad, Operating losses - 0.35 W / kVAr Over current withstand capability, 1.8 times rated current, Inrush current withstand capability, 300 times rated current, Operating life - 150000 hours, Number of switching, 8000 operations per year, conforming to IEC 60831-1+2/IS 13340-42. Provide Thermostat controlled panel mounted heavy duty exhaust fan in each Capacitor Compartment and space heater in Bus bar alley. INCOMER 1 No. 250A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended SUB BUSBARS 300Amps TP+N, 35kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar.

-

-

-

... More
Each Bus Section with 1 No Surge protection device Type 1 ( Class B),true status indication, 7 Mode, spark gap type suitable for 10/ 350µs surge,Voltage Protection level Up 4.0kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral & 3Nos. phase to earth and 1Nos. neutral to earth with discharge Current Imax. ≥ 50KA Per mode & In ≥ 25kA per Mode. Make & Model: Argos-AG-415-40T1-E or eq. SPD with 125A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 16sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. RELAYs 15 steps 3 phase, Microcontroller based Power factor correction Intelligent controller equivalent to TRINITYmake MODEL : ACCUVAR ,having PF monitoring and correction of indivisual phase, with multi functional display. The relay shall be sensitive to pick up 1% of rated current and correct the P.F accordingly. The relay should have Autosense feature to senses the size of each capacitor bank connected on each stage automatically. Should be able to Correct LAGGING POWER FACTOR AND LEADING POWER FACTOR. 1 No. off delay timer for manual operation. OUTGONIGS Each 8 Nos. 5 KVAR Capacitor Bank Feeders with 5KVAR Capacitor Duty TP contactor, 16A TP MCB (16kA), ON/OFF Indication lamps (LED Type) with control MCB, Auto / Manual selector switch, illuminated ON/OFF push buttons for manual operation, control wiring and protection with control MCB of required fault with stand capacity

-

-

-

... More
Each 4 Nos. 10 KVAR Capacitor Bank Feeders with 10KVAR Capacitor Duty TP contactor, 20A TP MCB (16kA), ON/OFF Indication lamps (LED Type) with control MCB, Auto / Manual selector switch, illuminated ON/OFF push buttons for manual operation, control wiring and protection with control MCB of required fault with stand capacity. Each 3 Nos. 15 KVAR Capacitor Bank Feeders with 15KVAR Capacitor Duty TP contactor, 32A TP MCB (16kA), ON/OFF Indication lamps (LED Type) with control MCB, Auto / Manual selector switch, illuminated ON/OFF push buttons for manual operation, control wiring and protection with control MCB of required fault with stand capacity. ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel with 1.5/2 mm thickness. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment.

-

-

-

... More
Note: Package Sub-staion will be complete with the internal interconnections & earthing. Accessories required for the external connections of HT & LT cables like termination kits , lugs , glands etc & extending of earth bar to earth pits will not be included in the above scope of offer. Packge Sub-Station is outdoor plinth mounted type. Erection , Commissiong and Civil work for package substation will not be in above scope. The Foundation details will be furnished by OEM. The CSS Design shall be comply with IS 14788 : 2000, IEC 61330/IEC 62271-202 and CPRI type tested not older than 1 year for similar of higher capacity etc. BMS Compatilility for VCB, Transformer, ACB and relay and MFM is required. a) 630kVA COMPACT SUB-STATION WITH CAPACITOR PANEL (FOR OR- BLOCK-3 & 4 & JCO BLOCK ) AS DESCRIBED ABOVE

2

-

-

... More
315 kVA COMPACT SUB-STATION WITH CAPACITOR PANEL (FOR TYPE-V BLOCK) Design, manufacture, supply at site, loading & unloading shifting, installation, testing and commissioning of compact sub-station consisting of 2IN LBS 1 VCB OUT, Transformer, capacitor and L.T. Panel as described below. HT SWITCHGEAR (H.V. COMPARTMENT) 11kV 630Amps 18.3KA for 3 Sec. SF6 insulated Non-Extinsible Compact RMU (Model No. FBX-C/12-25/CCT2) consisting of Incomer- 2 x Load break switch and Outgoing- 1 x Fixed Manual Vacuum Circuit Breaker each VCB with self powered microprocessor based numerical 3 over current & Earth Fault (IDMT+Inst.) relay in SF6 insulated stainless steel enclosure, with series trip for protection & metering. Interconnection between HT switchgear & transformer shall be with copper unarmorured XLPE 11kV H.T. Cable suitable for minimum 18.3kA for 3Sec. Relay should be capable of OTI/ WTI protection along with over current and Earth Fault. Provide 6 window annunciator with alarm and trip & hooter, 2 Window for over Current & Earth fault, 2 Window for OTI alarm & Trip & 2 Window for WTI alarm & Trip.

-

-

-

... More
INTERCONNECTION AND EARTHING Interconnection Between HT switchgear & Transformer using 1Cx3x95Sq.mm XLPE Single core Copper cable & Interconnection between Transformer & LT switchgear using Copper Busbars. Internal earthing connections by using 32x6 mm GI strips. TRANSFORMER COMPARTMENT 315KVA 11KV/433V Dyn11 Oil filled hermatically sealed copper wound transformer, Corruagated/PSR Radiators & Top normal porcelein Bushings for HT & LT with Off load tap switch of rating +5% to -10% @2.5%. Class 'A' of Thermal insulation, Suitable for Maximum Ambient temperature 45ºC & maximum winding temperature 105 deg cel (Make:- Same make of CSS) Losses standard with IS tol. Losses as per IS:1180 Level-3, BEE star 2 rating, & IS:2026 all parts latest as on date whichever is higher, Oil Temperature Indicator with Alarm and Trip contact + Winding Temperature Indicator with Alarm and Trip Contact including Manufacturer's BEE Certifications. L.V. COMPARTMENT INCOMER FROM TRANSFORMER 1 No. 630Amps 4P Fixed type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Cable connections on incomer side and bus bar connection at output sides.

-

-

-

... More
RELAYs, METERING INDICATOR & CT's 1 No. 30-3000mA 11kV ELR with CBCT with outgoing from VCB and 3Nos. 30-3000mA 1.1kV ELR with CBCT with outgoing from Transformer as shown in SLD. Provide 3Nos indicating lamps on each MCCB for status indication "ON", "OFF", and trip due to earth leakage for all outgoing. 1 No. Independent manual spring closing mechanism. Provide seprate 3Nos. CTs, Class-1, in each transformer Incoming bus section for capacitor panel APFCR. Provide 4Nos indicating lamps on each ACB for status indication "ON","OFF", tripped due to fault and trip circuit health for all ACB CT-Operated Trinity Make- Globin or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, Harmonics, Memory 2MB, HT/LT selectable, USB port, RS-485 Port, LCD display, 4 relay output for all incomers with class - 0.5 accuracy. CT-Operated Trinity Make- Power Pro or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Max. Demand, RS-485 Port, LCD display for all outgoings except outgoing for capacitor with class - 0.5 accuracy. BUSBARS SECTIONS 700Amps TP+N, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar.

-

-

-

... More
Each Bus Section with 1 No Surge protection device Type 1 ( Class B),true status indication, 7 Mode, spark gap type suitable for 10/ 350µs surge,Voltage Protection level Up 4.0kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral & 3Nos. phase to earth and 1Nos. neutral to earth with discharge Current Imax. ≥ 50KA Per mode & In ≥ 25kA per Mode. Make & Model: Argos-AG-415-40T1-E or eq. SPD with 125A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 16sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. OUTGOINGs 2 Nos. 630A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. 1 Nos. 160A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
CAPACITOR COMPARTMENT The capacitor banks in tier formation, Each capacitors specifications shall be MPP heavy duty cylindrical construction capacitors, 415Volts, 50 hz, Temp. Class-'C', Temp. of Air Surrounding the Capacitor - Max for 24hour- 45 deg. centigrade , Max. for a year 35 deg. Centigrad, Operating losses - 0.35 W / kVAr Over current withstand capability, 1.8 times rated current, Inrush current withstand capability, 300 times rated current, Operating life - 150000 hours, Number of switching, 8000 operations per year, conforming to IEC 60831-1+2/IS 13340-42. Provide Thermostat controlled panel mounted heavy duty exhaust fan in each Capacitor Compartment and space heater in Bus bar alley. INCOMER 1 Nos. 160A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended SUB BUSBARS 200Amps TP+N, 35kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar.

-

-

-

... More
Each Bus Section with 1 No Surge protection device Type 1 ( Class B),true status indication, 7 Mode, spark gap type suitable for 10/ 350µs surge,Voltage Protection level Up 4.0kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral & 3Nos. phase to earth and 1Nos. neutral to earth with discharge Current Imax. ≥ 50KA Per mode & In ≥ 25kA per Mode. Make & Model: Argos-AG-415-40T1-E or eq. SPD with 125A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 16sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. RELAYs 15 steps 3 phase, Microcontroller based Power factor correction Intelligent controller equivalent to TRINITYmake MODEL : ACCUVAR ,having PF monitoring and correction of indivisual phase, with multi functional display. The relay shall be sensitive to pick up 1% of rated current and correct the P.F accordingly. The relay should have Autosense feature to senses the size of each capacitor bank connected on each stage automatically. Should be able to Correct LAGGING POWER FACTOR AND LEADING POWER FACTOR. 1 No. off delay timer for manual operation. OUTGONIGS Each 15 Nos. 5 KVAR Capacitor Bank Feeders with 5KVAR Capacitor Duty TP contactor, 16A TP MCB (16kA), ON/OFF Indication lamps (LED Type) with control MCB, Auto / Manual selector switch, illuminated ON/OFF push buttons for manual operation, control wiring and protection with control MCB of required fault with stand capacity.

-

-

-

... More
ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel with 2 mm thickness. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment. Note;- Package Sub-staion will be complete with the internal interconnections & earthing. Accessories required for the external connections of HT & LT cables like termination kits , lugs , glands etc & extending of earth bar to earth pits will not be included in the above scope of offer. Packge Sub-Station is outdoor plinth mounted type. Erection , Commissiong and Civil work for package substation will not be in above scope. The Foundation details will be furnished by OEM. The CSS Design shall be comply with IS 14788 : 2000, IEC 61330/IEC 62271-202 and CPRI type tested not older than 1 year for similar of higher capacity etc. BMS Compatibility for VCB, Transformer, ACB and relay and MFM is required. a) 315 kVA COMPACT SUB-STATION WITH CAPACITOR PANEL (FOR TYPE-V BLOCK) AS DESCRIBED ABOVE

2

-

-

... More
800kVA COMPACT SUB-STATION (FOR SUBSTATION BLOCK) Design, Manufacture, Supply at site, loading and unloading shifting, installation, testing and commissioning of compact sub-station consisting of 2INCOMER LBS 1 VCB OUTGOING, Transformer, capacitor and L.T. Panel as described below. HT SWITCHGEAR (H.V. COMPARTMENT) 11kV 630Amps 18.3KA for 3 Sec. SF6 insulated Non-Extinsible Compact RMU (Model No. FBX-C/12-25/CCT2) consisting of Incomer- 2 x Load break switch and Outgoing- 1 x Fixed Manual Vacuum Circuit Breaker each VCB with self powered microprocessor based numerical 3 over current and Earth Fault (IDMT+Inst.) relay in SF6 insulated stainless steel enclosure, with series trip for protection & metering. Interconnection between HT switchgear and transformer shall be with copper unarmorured XLPE 11kV H.T. Cable suitable for minimum 18.3kA for 3Sec. Relay should be capable of OTI/ WTI protection along with over current and Earth Fault. Provide 6 window annunciator with alarm and trip & hooter, 2 Window for over Current & Earth fault, 2 Window for OTI alarm & Trip & 2 Window for WTI alarm & Trip. INTERCONNECTION AND EARTHING Interconnection Between HT switchgear & Transformer using 1Cx3x95Sq.mm XLPE Single core Copper cable & Interconnection between Transformer & LT switchgear using Copper Busbars. Internal earthing connections by using 32x6 mm GI strips.

-

-

-

... More
TRANSFORMER COMPARTMENT 800KVA 11KV/433V Dyn11 Oil filled hermatically sealed copper wound transformer, Corruagated / PSR Radiators & Top normal porcelein Bushings for HT & LT with Off load tap switch of rating +5% to -10% @2.5%. Class 'A' of Thermal insulation, Suitable for Maximum Ambient temperature 45º C and maximum winding temperature 105 deg cel (Make:- Same make of CSS) Losses standard with IS tol. Losses as per IS:1180 Level-3, BEE star 2 rating, & IS:2026 all parts latest as on date whichever is higher, Oil Temperature Indicator with Alarm and Trip contact + Winding Temperature Indicator with Alarm and Trip Contact including Manufacturer's BEE Certifications. L.V. COMPARTMENT INCOMER FROM TRANSFORMER 1 No. 1250Amps 4P Fixed type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Cable connections on incomer side and bus bar connection at output sides. RELAYs, METERING INDICATOR & CT's 1 No. 30-3000mA 11kV ELR with CBCT with outgoing from VCB and 3Nos. 30-3000mA 1.1kV ELR with CBCT with outgoing from Transformer as shown in SLD. Provide 3Nos indicating lamps on each MCCB for status indication "ON","OFF", and trip due to earth leakage for all outgoing. 1 No. Independent manual spring closing mechanism

-

-

-

... More
Provide seprate 3Nos. CTs, Class-1, in each transformer Incoming bus section for capacitor panel APFCR. Provide 4Nos indicating lamps on each ACB for status indication "ON","OFF" , tripped due to fault and trip circuit health for all ACB CT-Operated Trinity Make- Globin or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, Harmonics, Memory 2MB, HT/LT selectable, USB port, RS-485 Port, LCD display , 4 relay output for all incomers with class - 0.5 accuracy. ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel with 2 mm thickness. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment. Note:- Package Sub-staion will be complete with the internal interconnections & earthing. Accessories required for the external connections of HT & LT cables like termination kits , lugs , glands etc & extending of earth bar to earth pits will not be included in the above scope of offer. Packge Sub-Station is outdoor plinth mounted type. Erection , Commissiong and Civil work for package substation will not be in above scope. The Foundation details will be furnished by OEM. The CSS Design shall be comply with IS 14788 : 2000, IEC 61330/IEC 62271-202 and CPRI type tested not older than 1 year for similar of higher capacity etc. BMS Compatilility for VCB, Transformer, ACB and relay and MFM is required.

-

-

-

... More
800kVA COMPACT SUB-STATION (FOR SUBSTATION BLOCK) AS DESCRIBED ABOVE.

1

-

-

... More
800KVA OIL COOLED TRANSFORMER-1&2 800KVA 11/0.433kV ONAN WITH OLTC, RTCC & AVR WITH BUCHHOLZ, OTI AND WTI RELAYs Design, Manufacture, Supply at site, inspection of Consultant's/client at Factory at your cost of 800kVA rating continuous duty cycle, 11kV/0.433kV, 3 phase, 50Hz, Dyn-11 vector group, step down, outdoor type, copper wound, ONAN type transformers with On load tap changer with RTCC ( OLG make) and high voltage windings for varying low or high voltage in the range of +5% to -15% in 17 steps. Class 'A' of Thermal insulation Suitable for Maximum Ambient temperature 45º C. Maximum winding temprature 105º C The Following Fittings Shall Be provided with all required accessories:- Rating & Terminal Marking Plate, Earthing Terminals , Lifting Lugs For Main Tank & Top Cover, Filter Valve , Drain Cum Sampling Valve, Thermometer Pocket, Dial Type Oil Temperature Indicator, Air Release Plug, Silica Gel Breather, Explosion Vent, Inspection Cover, Arcing Horn, Radiators Mounted on Tank, 4 Nos. bi-directional Rollers, First Filling of Transformer Oil as per IS:335, 2Nos. Buchholz Relay (1 for trans. & 1 for OLTC), Oil Temperature Indicator, Winding Temperature Indicator, Magnetic Oil Level Gauge, Marshalling Box, Epoxy Bushing, PU Paints, Palm, LV Bus Bar, Radiator Valves, Cable Box on LT side suitable for termination of 4 No. 3.5 Core 300sqmm Al.Ar. Cable & Cable Box on HT side. Transformer shall Compliance to IS:1180 Level-3, BEE 2 Star Rating & IS:2026 all parts latest as on date whichever is higher. complete with all accessories. The transformer shall be delivered along with after complete factory tests and temprature rise test (incl. in cost), Manufacturer BEE Certifications, Operational & Maintenance manual and test certificate of unconditional guaranteed against manufacturing defects for a period of 18 months from the date of supply.

2

-

-

... More
DIESEL GENERATOR SETS Providing, Installing, Testing and Commissiong of 'Silent Type' Diesel Generating set alongwith Prime Power Rating 400KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415V suitable for 50 Hz, 3 phase system & for 0.80 Load Factor and consisting of the followings: i) Diesel Engine: Diesel engine 4 stroke radiator Cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 50 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continous operation. The engine will be fitted complete with electronic Governer and all the required accessories. ii) Engine mounted Instrument/control Panel fitted with and having digital display for following: (i) Start-stop switch with key (ii) Coolent (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication (vii) Over speed indication (viii) Low lub. Oil trip indication (ix) Engine Hours indication (x) Engine protection unit and sensors for winding & bearing temperature monitoring (xi) Remote Monitoring System

-

-

-

... More
iii) Alternator Synchronous alternator rated at 400KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.85 lagging power factor at 50 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having microprocessor based controller with BMS compatibility, SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation. Cable termination Box suitable to receive 2Nos. 3.5 core x 240 Sqmm XLPE Al. Ar. Cable. iv) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and antivibration mountings arrangement as per recommendations of manufacturer. v) Fuel Tank: (Internal) Daily service fuel tank of 350 liters capacity fabricated out of 3 mm thick M.S./CRCA sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. vi) Exhaust System: Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor. vii) Starting System: DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 1 x 120 AH, 12V capacity SMF lead acid type) as required as per specifications.

-

-

-

... More
vii) Accoustic for weather and noice proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per CPCB-II norm & technical specifications.

1

-

-

... More
Providing, Installing, Testing and Commissiong of 'Silent Type' Diesel Generating set alongwith Prime Power Rating 750KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415V suitable for 50 Hz, 3 phase system & for 0.80 Load Factor and consisting of the followings: Diesel Engine: Diesel engine 4 stroke radiator Cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 50 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continous operation. The engine will be fitted complete with electronic Governer and all the required accessories. Engine mounted Instrument/control Panel fitted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication (vii) Over speed indication (viii) Low lub. Oil trip indication (ix) Engine Hours indication (x) Engine protection unit and sensors for winding & bearing temperature monitoring (xi) Remote Monitoring System

-

-

-

... More
Alternator Synchronous alternator rated at 750KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.85 lagging power factor at 50 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having microprocessor based controller with BMS compatibility, SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation. Cable termination Box suitable to receive 4Nos. 3.5 core x 400 Sqmm XLPE Al. Ar. Cable. Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and antivibration mountings arrangement as per recommendations of manufacturer. Fuel Tank: (External) Daily service fuel tank of 990 liters capacity fabricated out of 3 mm thick M.S./CRCA sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Exhaust System: Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor. Starting System: DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 2 x 160AH, 12V capacity SMF lead acid type) as required as per specifications.

-

-

-

... More
Accoustic for weather and noice proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per CPCB-II norm & technical specifications.

1

-

-

... More
Supplying and fixing of exhaust gas piping of suitable dia. for following rating D.G. Set welded black MS, 'B' Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, the work include necessary cladding of exhaust pipe work using wiremesh, 50mm thick Loosely bound resin(LBR)mattress / mineral wool/ Rockwool, density not less than 150kg/m and aluminium cladding (0.6mm thick min.) for temperature up to 450°C, complete portion complete as required as per specifications.

-

-

-

... More
(a) 400mm dia minimum 4.85mm thick

15

-

-

... More
(b) 150mm dia

15

-

-

... More
Note- Contractor / Vendor to check the diameter of the exhaust pipes w.r.t. back pressure calculations & confirm the exhaust pipe sizes & suggest changes if required. This is to be done before supply of material / at the time of tendering. The contractor to measure actual pipe lengths as per site conditions & then confirm the suitability of pipe dia meters supported by back pressure calculations.

-

-

-

... More
Supplying and fixing of insulation around the silencer of the following rating DG Sets:- a.) 1No. 400kVA and b.) 1No. 750kVA, including necessary cladding work using wiremesh, 50mm thick Loosely bound resin(LBR)mattress / mineral wool/ Rockwool, density not less than 150kg/m and aluminium cladding (0.6mm thick min.) for temperature up to 450°C, complete portion complete as required as per specifications.

1

-

-

... More
STRUCTURE FOR EXHAUST PIPING Providing, febrication & fixing for MS support structure including civil foundation for exhaust fume pipes upto 10m high from ground level and from DG Sets (Exhaust pipe to be measured and paid for separately) along horizontal and vertical runs as per soil testing as per the soil test report and monkey ladder upto the height (In case of when exhaust pipe far from the building) including cutting, welding etc and applying two coats of red oxide and two coats of synthetic enamelled paint of colour and shade as directed by Engineer/ Client/ Authority. The design of the support structure shall be done by the D.G. Manufecture/contractor and shall be as per CPCB norms-II including 300MM Long lightning arrestor on top, 20x3 mm G.I. down strips mount on insulator and aviation light including wiring and connections from near by D.B.. Design shall be got approved from the Engineer/ Client/ Authority before execution as required.

1000

-

-

... More
Supplying & fixing Stainless Steel Expansion Joints, Corrugated bellow for 400kVA DG Sets to fit in exhaust pipe.

1

-

-

... More
Supplying & fixing Stainless Steel Expansion Joints, Corrugated bellow for 750kVA DG Sets to fit in exhaust pipe.

1

-

-

... More
ELECTRICAL PANELS. Supplying, installation, testing & commissioning of Totally Type Tested Panels complying IEC 61439 -1/2 cubical with Internal arc withstand and impact resistance IK10 as per ICE62262. The panel shall be tested for an internal arc of 50kA for 0.5 seconds. The degree of protection of minimum IP 42 for indoor and IP 55 for outdoor use. Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of minimum 2 mm thick for load bearing member and 1.6mm for Non load bearing member, 3mm thick for gland, plates i/c cleaning & finishing complete, having extensible type aluminium bus bars of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 50kA for 1 Sec., bottom frame shall be 100mm Height as per OEM standard, fabrication shall be done in transportable sections, Entire panel shall have a common aluminium earth bar of size 32mm x 6mm or as specified below at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al with form-4B construction. bus bars and control wiring with suitable size of PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-

-

-

-

... More
General Notes for site visit report for Panels/ Rising Main before submitting GA. The Manufacturer must visit the site before submitting GA drawings and submit a report consisting following: Possible height for Panel. Possible width for Panel Back access will be possible or not. Cable entry will be from top or bottom. If entry from bottom whether MS. Stand is required or not. If the panel is wall mounted whether the wall is available or not. Path for movement of transportation of panel is possible or not i.e length, width etc. and the transportation sections shall be designed accordingly. Sufficient space available at front & back after door opening. Sufficient height available above panel for cable drop. Actual floor to floor height for rising mains. Also, refer to General Notes and Specifications for Panels/ Boards. Contractor to submit manufacturer's selection charts, Total discrimination and curves prove the same, insulation material & corners cover on bus-bars for approval. Feeders should be totally bolted structure with interchangeable feeder. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. SMC shrouds bus bar supports shall be used. Padlocking facility shall be provided on all MCCB feeder doors and switch handles shall be lockable in OFF position. Sealing Arrangement :- PE Foam Rubber Gasket Bus Bars Supports - Non-Hygroscopic, Non Carbonising, Corrosion Resistant, SMC Supports 1Set of connector (Phase+Neutral) shall be provided in cable alley for all outgoing with interconnection wires between MCB and Connector.

-

-

-

... More
Minimum Air Clearances between bus bars shall be as per IEC 61439 Clause 8.2.5; Panel Power and control Wiring all ZHLS PVC insulated AC voltage circuit-1.5 sqmm Red,Yellow,Blue & Black Current circuit-1.5 sqmm Red,Yellow,Blue & Black AC Control circuit-1.5 sqmm White for Phase & Black for Neutral DC Control circuit-2.5 sqmm Grey Power circuit- Red,Yellow,Blue for Phase &Black for Neutral Labeling- Computerised Laminated Aluminium Name Plate with White letters on Blue/Black Background For Each Feeder and Panel Itself. Note: 1) If mentioned fault and Automatic transfer switch rating is unavailable consider nearby upside rating 2) A separate compartment for Minimum 20% spare space of Panel shall be provided for outgoings in future and busbars shall be drilled accordingly. 3) Total Discrimination of system shall be checked and required setting shall be made. If any component required to change will change free of cost. The switch-gear & Panel manufacturer (jointly) will submit discrimination check report duly checked and signed on company letter head.

-

-

-

... More
1) GENERAL NOTES FOR ACB's: ACB shall be with 4 NO + 4 NC Auxiliary contacts. Safety Shutter. Door Sealing Frame. Inbuilt TRIP LED indication. ON/ OFF/ TRIP status on EthernetIcs Icu = Icw for 1 sec. for the breakers. With built in micro-processor based releases: Adjustable over current with time setting. Adjustable short circuit with time setting. Instantaneous short circuit. Adjustable earth fault with time setting. Power wiring with one size higher terminals / bus bars for termination of cables as specified. There shall be no deration upto 50 degree celcius. ACBs shall be provided with both side terminal adaptors (Preferably Hr Vr) All the ACBs shall be features like ZSI, Thermal Memory, last 10 trip histories, current & Voltage Metering, % loading Bar graph, LED fault differentiation. 2) GENERAL NOTES FOR MCCB's: MCCB's shall be of TPN (3P with solid neutral link) or 4P as called for in the BOQ. Ics = Icu = 100% or more for the breakers. MCCB's shall be with thermal - magnetic/ Micropocessor based releases as mentioned in BOQ. All Thermal Magnetic MCCB's shall have adjustable over current and Fixed short circuit.

-

-

-

... More
All micro-processor based MCCB's shall have adjustable over current with time setting, adjustable short circuit and Adjustable earth fault with indication due to earth fault. MCCB's shall be with extended rotary handle with Phase spreaders & Phase Barriers at both sides. MCCB's shall have auxiliary contacts wherever BMS compatibility is needed. MCCB of required rating (Amps) as called for in the BOQ and of required breaking capacity. All MCCBs above 250A shall be microprocessor based. Thermal Magnetic MCCBs shall have modular external earth fault protection. 3) GENERAL NOTES FOR MCB's: MCB's shall be of minimum 10kA breaking capacity for 1 sec. Use 'B' curve MCB's for lighting & small power circuits, 'C' curve for motor duty i.e. for pumps, AC motors, AHU motors, window and split AC's etc. & 'D' curve for UPS DB's i.e. for computers/ PC's circuit. Main Incomer & outgoing circuit MCB's shall be selected accordingly i.e. type B,C & D. as per the nature of the circuit/ load. Exact MCB rating & category is to be calculated by the electrical contractor based on the final load of the circuit, its nature and fault current. 4) GENERAL NOTES FOR TRANSIENT VOLTAGE SURGE SUPPRESSOR (TVSS): Transient Voltage Surge Suppressors (TVSS) shall be mounted out side the panel / switch board in a sheet steel enclosure. It shall be suitable for handling required (specified) surge handling capacity, shall be 10 modes protection with noise filters. (EMI & RFI) and with inbuilt back up fuse protection. Surge suppressor shall be complete with isolating / protective device in the form of MCCB of KA rating (breaking capacity) as of switch board.

-

-

-

... More
ESS BLOCK MAIN LT PANEL FOR ESSENTIAL LOAD INCOMER-1 From TRANSFORMER-1 : 1Nos.320A 4P MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) with 4P AC1 Contactor with wide band coil of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. INCOMER-2 400kVA D.G. Set : 1 No. 630Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides.

-

-

-

... More
INCOMER-3 750kVA D.G. Set : 1 No. 1250Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides. INCOMER-4 From Solar Panel 1 No. 100A 4P MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. ( For Solar supply input). INCOMER-5 & 6 FromTRANSFORMER-2&3: 1 No. 1250Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides.

-

-

-

... More
BUS - COUPLER 1 No. 630Amps 4P EDO type Air circuit breaker without protection release of fault breaking capacity 50KA (Ics=Icu=Icw upto 433V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB, terminals suitable for Bus bar connections on both sides. 1 No. 1500Amps 4P EDO type Air circuit breaker without protection release of fault breaking capacity 50KA (Ics=Icu=Icw upto 433V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB, terminals suitable for Bus bar connections on both sides. METERING, RELAY, INDICATOR & CT's 1 Set of R,Y,B phase indication lamps with control MCB as per fault requirement for each Incomer. Provide 4Nos indicating lamps on each ACB for status indication "ON","OFF" , tripped due to fault and Trip circuit healty for all ACB Provide seprate 3Nos. CTs, Class-1, in each Transformer Incoming-1&2 bus section for capacitor panel APFCR. Provide seprate 3Nos. CTs, Class-1, in each Transformer Incoming-1&2 bus section for capacitor panel APFCR. 1Set of trip due to earth leakage Indication lamps with each Earth Leakage Relay.

-

-

-

... More
1 No. Independent manual spring closing mechanism 1 No. 30-3000mA ELR with tape wound CBCT each for total 28Nos. outgoings except Guard room DB, Sentry Post DB, external light Panel & jockey pump as shown in SLD. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Harmonics, Max. Demand, RS-485 Port, graphical LCD display with 2 relay output for all incoming with class - 0.5 accuracy. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kwH, kVAH (EB & DG), LCD display for all outgoings with class - 0.5 accuracy. 1 set-Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection for all incoming except Bus coupler. Auxiliary Relays as required. Single phase preventer, Under voltage, Over voltage relay for each transformer & D.G. set Incomer with indicator for trip and hooter for alarm. Reverse power relay, under frequency & over frequency relay for each D.G. set Incomer with indicator for trip and hooter for alarm AMF/Cranking & Auxilary Relay micro-controller based unit 3P4W to automatic generator start/stop, Three Phase montoring & measures for A,V&Hz and LCD displays 20 x 4 Line. Password protected programmable parameters and stored in a non volatile memory for information is retained in the event of complete loss of battery power. AMF can be operated in "AUTO","QAUTO" (Quick Auto) or "MANUAL" mode. The unit shall features a non-erasable incremental "DG run hour" and "maintenance hour. The "CT ratio" should site selectable. Self powered by a wide input (9-36VDC) power supply and ON/OFF delay site configurable timers. include with 3 Nos. Resin cast CTs, Class-1

-

-

-

... More
Provide control accessories like automatically controlled constant voltage constant current, 24/12 V DC battery charger with battery charging indication, battery charged indication, Over charged battery protection, low battery protection, High Voltage protection, charger on - AC, DC Ammeter, DC Voltmeter, 8 window fault annunciater with inbuilt P.B and Hooter, trip alarm and reset etc. for each D.G. Set incomer. Phase Reversal relay for each Transformer incomer with indicator for trip and hooter for alarm. BUSBARS SECTIONS-1 800Amps TPN, 50kA, 500volts grade busbar chamber of suitable length with aluminium busbars. All interconnections shall be with aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for aluminium cross sectional area of Bus Bar. BUSBARS SECTIONS-2 & 3 1500Amps TPN, 50kA, 500volts grade busbar chamber of suitable length with aluminium busbars. All interconnections shall be with aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for aluminium cross sectional area of Bus Bar. OUTGOINGS CONNECTED AS SHOWN IN SLD: 2 Nos. 800A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
4 Nos. 630A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 4 Nos. 400A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 3 Nos. 320A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 2 Nos. 250A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
4 Nos. 200A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 2 Nos. 160A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 2 Nos. 125A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 5 Nos. 100A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
13 Nos. 63A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 2 Nos. 32A TPN, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 4 Nos. 32A DP, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O.

-

-

-

... More
PLC FOR INTERLOCKING & LOAD MANAGEMENT Relay For Interlocking, Load Management & Auto D.G. Start/Stop etc. ( Total D.G. Sets are 1x400kVA + 1x750kVA + 3x800kVA Transformers (2W+1S) + 2Nos. Bus-coupler). Provide wood ward make EG3200 relay with all D.G. incomer, U/O Voltagte relay with each Transformer Incomer and buscouplers or eq. make for Electrical interlocking between each incomers and buscouplers as shown in SLD, Auto D.G. selection and Start/Stop, Load management including arrangement Nesecarry arrangments, control wiring, Softwere and Hardwares need to be provided for system. 1kVA online UPS with minimum 15 minutes backup, built in battery for PLC system. MIMIC DIAGRAM a) MAIN LT PANEL FOR ESSENTIAL LOAD as described above.

1

-

-

... More
250 Kvar Capacitor Panel: Automatic Power Factor Correction : WITH DETUNED HARMONICS REACTORS CONTACTOR BASED SWITCHING. The capacitor banks in tier formation, Each capacitors specifications shall be MPP HEAVY duty cylindrical construction Oil Filled capacitors, 415/440/480/525Volts, 50 hz, Temp. Class-'D', Operating losses - 0.0025 (TAN DELTA), Over current withstand capability, 1.3 times rated current, 200 x In Inrush current withstand capability rated current, Operating life - 30,000 hours, Having over pressure disconnector switch, Number of switching, 3000 operations per year, conforming to IEC 60831-1+2/IS 13340-42. Provide Thermostat controlled panel mounted heavy duty exhaust fan in each Capacitor Compartment and space heater in Bus bar alley. Automatic Power Factor Correction Relay 12 steps 3 phase, Microcontroller based Power factor correction Intelligent controller equivalent to Trinity make Model : VARLOG, having PF monitoring and correction of individual phase, with multi functional display. The relay shall be sensitive to pick up 1% of rated current and correct the P.F accordingly. The relay should have Autosense feature to senses the size of each capacitor bank connected on each stage automatically. Should be able to Correct lagging power factor and leading power factor. E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. Provide 4Nos indicating lamps on each ACB for status indication "ON","OFF" , tripped Due to Earth fault & Trip circuit healty and true operation counter for all ACB. Start/Stop illuminated push buttons, Auto/Manual/off selector switch 2P/2W+OFF, ON/OFF/TRIP indicator, Timer each backed up with HRC fuses with provide complete set for each outgoing contactor.

-

-

-

... More
2 Nos. Flashing Buzzer Over / Under Compensation 1Set of alarm and indication if the power factor goes lagging below from 0.85 and leading above from 1.0 also if life cycle to complete of capacitor panel. INCOMER 1 No. 630A TP+NL MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. BUS BARS 600Amps TP+N, 35kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar. OUTGOINGS Each below capacitor bank feeder shall be with TP capacitor duty contactor of same required kVAR, door mount toggle Switch & light for each capacitor compartment, control wiring and backed up HRC Fuse. MCCB provided with capacitor, shall have built in thermal magnetic based release (fixed O/L & fixed S/C) protections and external earth lekage relay of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with knob with Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. Each below Capacitor Bank of required kVAR with 14% detuned reactor. In case of capacitor bank with detuned reactor, the operating voltage of capacitor shall be 415V minimum as per capacitor OEM recommondations.

-

-

-

... More
CAPACITOR 2 Nos. 50 KVAR Capacitor Bank Feeders each with 100A TP, MCCB built in thermal magnetic bases release (adjustable O/L, S/C&E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V. 2 Nos. 25 KVAR Capacitor Bank Feeders each with 63A TP, MCCB built in thermal magnetic bases release (adjustable O/L, S/C&E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V 6 Nos. 15 KVAR Capacitor Bank Feeders each with 32A TP, MCCB built in thermal magnetic bases release (adjustable O/L, S/C&E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V 2 Nos. 5 KVAR Capacitor Bank Feeders each with 16A TP, MCCB built in thermal magnetic bases release (adjustable O/L, S/C&E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. a) 250kVAR Capacitor Panel as described above.

3

-

-

... More
TRANSFORMER PANEL-OR's BLOCK-1&2 COMMON AREA INCOMER 1 No. 1600 Amps TP+Neutral link MDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides. METERING, RELAY, INDICATOR & CT's 1 Set R,Y,B phase indication lamps with control MCB as per fault requirement for each Incomer. Provide seprate 3Nos. CTs, Class-1, in each Transformer Incoming bus section for capacitor panel APFCR. Provide 4Nos indicating lamps on each ACB for status indication "ON","OFF" , tripped due to fault and Trip circuit healty for all ACB. Provide 3Nos indicating lamps on each MCCB for status indication "ON","OFF" , and trip due to earth leakage for all outgoing. 1 No. Independent manual spring closing mechanism CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, Harmonics, Memory 2MB, HT/LT selectable, USB port, RS-485 Port, LCD display , 4 relay output for all incomers with class - 0.5 accuracy.

-

-

-

... More
CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Max. Demand, RS-485 Port, LCD display for all outgoings with class - 0.5 accuracy. 1Nos. 30-3000mA ELR with tape wound CBCT each for all outgoings as shown in SLD. 1 set-Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection for all incoming except Bus coupler. Auxiliary Relays as required. Single phase preventer, Under voltage, Over voltage relay for Incomer with indicator for trip and hooter for alarm. Reverse power relay, under frequency & over frequency relay for Incomer with indicator for trip and hooter for alarm Phase Reversal relay with incomer with indicator for trip and hooter for alarm. BUSBARS 2000Amps TP+N, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar. OUTGOINGS CONNECTED AS SHOWN IN SLD: 1 No. 1250Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides.

-

-

-

... More
1 No. 630A TP+NL MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. 1 No. 320A TP+NL MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. Each Bus Section with 1 No Surge protection device Type 1 ( Class B),true status indication, 7 Mode, spark gap type suitable for 10/ 350µs surge,Voltage Protection level Up 4.0kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral & 3Nos. phase to earth and 1Nos. neutral to earth with discharge Current Imax. ≥ 50KA Per mode & In ≥ 25kA per Mode. Make & Model: Argos-AG-415-40T1-E or eq. SPD with 125A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 16sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. a) TRANSFORMER PANEL-OR's BLOCK-1&2 COMMON AREA as described above.

1

-

-

... More
MDB-2 (OR's Block-1&2) INCOMER 1 No. 1250Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides. CTs, METERING & INDICATIONS 1 Set of R,Y,B phase Indication lamps controlled with control MCB's incomer. Provide 4Nos indicating lamps on each ACB for status indication "ON","OFF" , tripped Due to Earth fault & Trip circuit healty and true operation counter for all ACB. Provide 1Set indicating lamps for status indication "ON","OFF" , tripped due to Earth leakage for all outgoings. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Harmonics, Max. Demand, RS-485 Port, graphical LCD display with 2 relay output for all incoming with class - 0.5 accuracy. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Max. Demand, RS-485 Port, LCD display for all outgoings with class - 0.5 accuracy. 1Nos. 30-3000mA ELR with tape wound CBCT each for all outgoing as shown in SLD.

-

-

-

... More
BUS BARS 1600Amps TP+N, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar. OUTGOINGS 5 Nos. 200A TPN MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 6 Nos. 63A TPN MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O.

-

-

-

... More
Necessary Mounting MS stand of 300mm height with 2Nos of coating of anti corrision paint and 1No. Final coating of black paint. The cost shall include here. a) MDB (OR's Block-1&2) as described above.

1

-

-

... More
SDB-1 (ESSENTIAL PANEL) OR's BLOCK 1&2 INCOMER 2 Nos. 630A 4P MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 1 No. 100A 4P MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. ( For Solar supply input). Mechnical & Electrical interlocking between both Main incomers CTs, METERING & INDICATIONS 1 Set of R,Y,B phase Indication lamps controlled with control MCB's. with each incomer. Provide 1Set indicating lamps for status indication "ON","OFF" , tripped due to Earth leakage with each incomer. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, Harmonics, Memory 2MB, HT/LT selectable, USB port, RS-485 Port, LCD display , 4 relay output for all incomers with class - 0.5 accuracy. Single phase preventer, Under voltage, Over voltage relay for Incomer with indicator for trip and hooter for alarm.

-

-

-

... More
1Nos. 30-3000mA ELR with tape wound CBCT each for all incomer as shown in SLD. BUS BARS 700Amps 4P, 25kA, 500volts grade busbar chamber of suitable length with aluminium busbars. All interconnections shall be with aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for aluminium cross sectional area of Bus Bar. OUTGOINGS 2 Nos. 100A 4P MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 18Nos. 63A, 10kA, 4P MCB with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 20Nos. 32A, 10kA, 4P MCB with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy.

-

-

-

... More
2 Nos. 40A, 10kA, DP MCB 2 Sets of (1Nos. 25A, 10kA, 4P MCB + 1Nos. 25A, TP AC3 Contactor) with Auto/Manual Selector Switch, Start/Stop push button, on/off/Trip indications with control MCB. 2 Nos. Astronomical time switches with in- built minimum 5 years battery back up and USB keys. Conform to IEC 60730, Operating voltage : 230V, 50Hz, Hager make-EE181 or Eq. Make. Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. Necessary Mounting MS stand of 300mm height with 2Nos of coating of anti corrision paint and 1No. Final coating of black paint. The cost shall include here.

-

-

-

... More
SDB-1 (ESSENTIAL PANEL) OR's BLOCK 1&2 as described above.

1

-

-

... More
MDB-2 (OR's Block-3&4) INCOMER 1 No. 1000Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides. CTs, METERING & INDICATIONS 1 Set of R,Y,B phase Indication lamps controlled with control MCB's incomer Provide 4Nos indicating lamps on each ACB for status indication "ON","OFF", tripped Due to Earth fault & Trip circuit healty and true operation counter for all ACB. Provide 1Set indicating lamps for status indication "ON","OFF", tripped due to Earth leakage for all outgoings. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Harmonics, Max. Demand, RS-485 Port, graphical LCD display with 2 relay output for all incoming with class - 0.5 accuracy. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Max. Demand, RS-485 Port, LCD display for all outgoings with class - 0.5 accuracy. 1Nos. 30-3000mA ELR with tape wound CBCT each for all outgoing as shown in SLD.

-

-

-

... More
BUS BARS 1200Amps TP+N, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar. OUTGOINGS 5 Nos. 200A TPN MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 6 Nos. 63A TPN MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. Necessary Mounting MS stand of 300mm height with 2Nos of coating of anti corrision paint and 1No. Final coating of black paint. The cost shall include here.

-

-

-

... More
MDB (OR's Block-3&4) as described above.

1

-

-

... More
SDB-2 (ESSENTIAL PANEL) OR's BLOCK 3&4 INCOMER 2 Nos. 630A 4P MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 1 No. 100A 4P MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. ( For Solar supply input). Mechnical & Electrical interlocking between both Main incomers. CTs, METERING & INDICATIONS 1 Set of R,Y,B phase Indication lamps controlled with control MCB's. with each incomer. Provide 1Set indicating lamps for status indication "ON","OFF" , tripped due to Earth leakage with each incomer. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, Harmonics, Memory 2MB, HT/LT selectable, USB port, RS-485 Port, LCD display , 4 relay output for all incomers with class - 0.5 accuracy.

-

-

-

... More
Single phase preventer, Under voltage, Over voltage relay for Incomer with indicator for trip and hooter for alarm. 1 No. 30-3000mA ELR with tape wound CBCT each for all incomer as shown in SLD. BUS BARS 700Amps 4P, 25kA, 500volts grade busbar chamber of suitable length with aluminium busbars. All interconnections shall be with aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for aluminium cross sectional area of Bus Bar. OUTGOINGS 2 Nos. 100A 4P MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 18Nos. 63A, 10kA, 4P MCB with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 20Nos. 32A, 10kA, 4P MCB with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy.

-

-

-

... More
1 No. 40A, 10kA, 4P MCB 2 Sets of (1Nos. 25A, 10kA, 4P MCB + 1Nos. 25A, TP AC3 Contactor) with Auto/Manual Selector Switch, Start/Stop push button, on/off/Trip indications with control MCB. 2 Nos. Astronomical time switches with in- built minimum 5 years battery back up and USB keys. Conform to IEC 60730, Operating voltage : 230V, 50Hz, Hager make-EE181 or Eq. Make. Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3 Nos. phase to neutral and 1 No. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV, CE, ROHS, UL94V-O. Necessary Mounting MS stand of 300mm height with 2 Nos of coating of anti corrision paint and 1 No. Final coating of black paint. The cost shall include here.

-

-

-

... More
SDB-2 (ESSENTIAL PANEL) OR's BLOCK 3&4 as described above.

1

-

-

... More
MDB (JCO's Block-1&2) INCOMER 1 No. 1000Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides. CTs, METERING & INDICATIONS 1 Set of R,Y,B phase Indication lamps controlled with control MCB's incomer Provide 4Nos indicating lamps on each ACB for status indication "ON","OFF" , tripped Due to Earth fault & Trip circuit healty and true operation counter for all ACB. Provide 1Set indicating lamps for status indication "ON","OFF" , tripped due to Earth leakage for all outgoings. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Harmonics, Max. Demand, RS-485 Port, graphical LCD display with 2 relay output for all incoming with class - 0.5 accuracy. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Max. Demand, RS-485 Port, LCD display for all outgoings with class - 0.5 accuracy. 1Nos. 30-3000mA ELR with tape wound CBCT each for all outgoing as shown in SLD.

-

-

-

... More
BUS BARS 1200Amps TP+N, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars. All interconnections shall be with Aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for Aluminium cross sectional area of Bus Bar. OUTGOINGS 5 Nos. 200A TPN MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. Necessary Mounting MS stand of 300mm height with 2Nos of coating of anti corrision paint and 1No. Final coating of black paint. The cost shall include here.

-

-

-

... More
MDB (JCO's Block-1&2) as described above.

1

-

-

... More
MDB (BLOCK TYPE- V) INCOMER & BUS COUPLER 2 Nos. 630A 4P MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 1 No. Bus coupler 630A 4P MCCB Microprocessor based of fault breaking capacity 35KA (Ics=Icu) upto 500V manually operated and without protection relays, extended rotary handle for door interlock with Phase spreaders & Phase Barriers at both sides. Mechnical & Electrical interlocking between incomers and coupler. CTs, METERING & INDICATIONS 1 Set of R,Y,B phase Indication lamps controlled with control MCB's with each incomer Provide 3 Nos indicating lamps for status indication "ON","OFF" , tripped due to Earth fault for all incomer. Provide 3 Nos indicating lamps for status indication "ON","OFF" , tripped due to Earth leakage for all outgoing. Provide 2 Nos indicating lamps for status indication "ON","OFF" for buscoupler CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, Harmonics, Max. Demand, RS-485 Port, graphical LCD display with 2 relay output for all incoming with class - 0.5 accuracy.

-

-

-

... More
CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy for each outgoing. 1Nos. 30-3000mA ELR with tape wound CBCT each for all outgoings as shown in SLD. BUS BAR 1 & 2 700Amps TPN, 35kA, 500volts grade busbar chamber of suitable length with aluminium busbars. All interconnections shall be with aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for aluminium cross sectional area of Bus Bar. OUTGOINGS 4 Nos. 630A ( To be tripprd set on 500A) TPN MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories.

-

-

-

... More
The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. 1 No. black painted MS stand of 300mm height. MDB (BLOCK TYPE- V) as described above.

1

-

-

... More
Design, Manufacture, Supplying, Transport to the site, Receiving, Unloading, Shifting to Sub-Station at various locations, handling, assembling, installation in correct aligned position, making proper connections, grouting with dash fasteners, GI nuts-bolts, testing and commissioning of the following Modular cubical type construction, Electrical Panels up to 450Volts ±10%, 3Phase, 4Wire, 50Hz ±6%, are housed in CRCA Sheet bolted cubicle made up of 1.6mm for non-stress members & 2.0mm for all stress bearing members and 3.0mm for Removable Glad Plate & base Frame Meterial, unless specified otherwise, vermin proof hinged lockable doors & door earthed for each compartment provide bus bar interconnections for incoming and outgoing, Single front compartmentalized, totally enclosed, free standing, Floor / Wall mounted type as case may, indoor (IP: 44) / semi outdoor (IP:54) / Fully Outdoor (IP:65), extendible type, duly wired up and ready for installation at site. The Bus bars will be Copper purity 99.9% / electrolytic grade E91 Aluminium duly sleeved with Helogen Free heat shrink coloured Insulated tube (make-GALA or Eq.) confirms to RoHS & IEC 6068-3-247 Standard. Provide electrical insulating shrouds, reusable type covers for busbars Boots on corners Panels will be painted with Powder coating (60-80micron as per IS:13871 for indoor and 90-100 micron for outdoor), include one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB/MCCB. General Notes for site visit report for Panels/ Rising Main before submitting GA.

-

-

-

... More
The Manufacturer must visit the site before submitting GA drawings and submit a report consisting following: Possible height for Panel. Possible width for Panel. Back access will be possible or not. Cable entry will be from top or bottom. If entry from bottom whether MS. Stand is required or not. If the panel is wall mounted whether the wall is available or not. Path for movement of transportation of panel is possible or not i.e length, width etc. and the transportation sections shall be designed accordingly. Sufficient space available at front & back after door opening. Sufficient height available above panel for cable drop. Actual floor to floor height for rising mains. Also, refer to General Notes and Specifications for Panels/ Boards. Contractor to submit manufacturer's selection charts, curves prove the same, insulation material & corners cover on bus-bars for approval. Feeders should be totally bolted structure with interchangeable feeder.

-

-

-

... More
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. SMC shrouds bus bar supports shall be used. Padlocking facility shall be provided on all MCCB feeder doors and switch handles shall be lockable in OFF position. Sealing Arrangement :- PE Foam Rubber Gasket Bus Bars Supports - Non-Hygroscopic, Non Carbonising, Corrosion Resistant, SMC Supports 1 Set of connector (Phase+Neutral) shall be provided in cable alley for all outgoing with interconnection wires between MCB and Connector. Minimum Air Clearances between bus bars shall be as per IEC 61439 Clause 8.2.5; Panel Power and control Wiring all ZHLS PVC insulated. AC voltage circuit-1.5 sqmm Red,Yellow,Blue & Black Current circuit-1.5 sqmm Red,Yellow,Blue & Black AC Control circuit-1.5 sqmm White for Phase & Black for Neutral DC Control circuit-2.5 sqmm Grey Power circuit- Red,Yellow,Blue for Phase &Black for Neutral Labeling- Computerised Laminated Aluminium Name Plate with White letters on Blue/Black Background For Each Feeder and Panel Itself.

-

-

-

... More
Note: 1) If mentioned fault and Automatic transfer switch rating is unavailable consider nearby upside rating. 2) A separate compartment for Minimum 20% spare space of Panel shall be provided for outgoings in future and busbars shall be drilled accordingly. 3) Total Discrimination of system shall be checked and required setting shall be made. If any component required to change will change free of cost. The switch-gear & Panel manufacturer (jointly) will submit discrimination check report duly checked and signed on company letter head. 1) GENERAL NOTES FOR ACB's: ACB shall be with 4 NO + 4 NC Auxiliary contacts. Safety Shutter. Door Sealing Frame. Inbuilt TRIP LED indication. Ics = Icu = Icw for 1 sec. for the breakers. With built in micro-processor based releases: Adjustable over current with time setting. Adjustable short circuit with time setting. Instantaneous short circuit. Adjustable earth fault with time setting. Power wiring with one size higher terminals / bus bars for termination of cables as specified. ON/OFF/TRIP status on Ethernet There shall be no deration upto 50 degree celcius ACBs shall be provided with both side terminal adaptors (Preferably Hr Vr) All the ACBs shall be features like ZSI, Thermal Memory, last 10 trip histories, current & voltage Metering, % loading Bar graph, LED fault differentiation.

-

-

-

... More
2) GENERAL NOTES FOR MCCB's: MCCB's shall be of TPN (3P with solid neutral link) or 4P as called for in the BOQ. Ics = Icu = 100% or more for the breakers. MCCB's shall be with thermal - magnetic/ Micropocessor based releases as mentioned in BOQ. All Thermal Magnetic MCCB's shall have adjustable over current and fixed short circuit. All micro-processor based MCCB's shall have adjustable over current with time setting, adjustable short circuit and Adjustable earth fault with indication due to earth fault. MCCB's shall be with extended rotary handle with Phase spreaders & Phase Barriers at both sides. MCCB's shall have auxiliary contacts wherever BMS compatibility is needed. MCCB of required rating (Amps) as called for in the BOQ and of required breaking capacity. All MCCBs above 250A shall be microprocessor based. Thermal Magnetic MCCBs shall have modular external earth fault protection. 4) GENERAL NOTES FOR MCB's: MCB's shall be of minimum 10kA breaking capacity for 1 sec. Use 'B' curve MCB's for lighting & small power circuits, 'C' curve for motor duty i.e. for pumps, AC motors, AHU motors, window and split AC's etc. & 'D' curve for UPS DB's i.e. for computers/ PC's circuit. Main Incomer & outgoing circuit MCB's shall be selected accordingly i.e. type B,C & D. as per the nature of the circuit/ load. Exact MCB rating & category is to be calculated by the electrical contractor based on the final load of the circuit, its nature and fault current.

-

-

-

... More
4) GENERAL NOTES FOR TRANSIENT VOLTAGE SURGE SUPPRESSOR (TVSS): Transient Voltage Surge Suppressors (TVSS) shall be mounted out side the panel / switch board in a sheet steel enclosure. It shall be suitable for handling required (specified) surge handling capacity, shall be 10 modes protection with noise filters. (EMI & RFI) and with inbuilt back up fuse protection. Surge suppressor shall be complete with isolating / protective device in the form of MCCB of KA rating (breaking capacity) as of switch board.

-

-

-

... More
SDB-3A (ESSENTIAL PANEL) JCO's BLOCK-1 INCOMER 2 Nos. 320A 4P MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 1 No. 100A 4P MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. ( For Solar supply input) Mechnical & Electrical interlocking between both Main incomers CTs, METERING & INDICATIONS 1 Set of R,Y,B phase Indication lamps controlled with control MCB's. with each incomer Provide 1Set indicating lamps for status indication "ON","OFF" , tripped due to Earth leakage with each incomer. CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, Harmonics, Memory 2MB, HT/LT selectable, USB port, RS-485 Port, LCD display , 4 relay output for all incomers with class - 0.5 accuracy. Single phase preventer, Under voltage, Over voltage relay for Incomer with indicator for trip and hooter for alarm.

-

-

-

... More
1 No. 30-3000mA ELR with tape wound CBCT each for all incomer as shown in SLD. BUS BARS 400Amps 4P, 25kA, 500volts grade busbar chamber of suitable length with aluminium busbars. All interconnections shall be with aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for aluminium cross sectional area of Bus Bar. OUTGOINGS 2 Nos. 100A 4P MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 16 Nos. 63A, 10kA, 4P MCB with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 6 Nos. 40A, 10kA, 4P MCB with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy.

-

-

-

... More
5 Nos. 32A, 10kA, 4P MCB with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 2Nos. 63A, 10kA, 4P MCB 1 No. 40A, 10kA, 4P MCB 3 Nos. 25A, 10kA, 4P MCB 1 No. 40A, 10kA, DP MCB 1 Set of (1Nos. 25A, 10kA, 4P MCB + 1Nos. 25A, TP AC3 Contactor) with Auto/Manual Selector Switch, Start/Stop push button, on/off/Trip indications with control MCB. 1 No. Astronomical time switches with in- built minimum 5 years battery back up and USB keys. Conform to IEC 60730, Operating voltage : 230V, 50Hz, Hager make-EE181 or Eq. Make. Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. Necessary Mounting MS stand of 300mm height with 2Nos of coating of anti corrision paint and 1No. Final coating of black paint. The cost shall include here.

-

-

-

... More
SDB-3A (ESSENTIAL PANEL) JCO's BLOCK-1 as described above.

1

-

-

... More
SDB-4 (ESSENTIAL PANEL) BLOCK TYPE-V INCOMER 2 Nos. 200A 4P MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. 1 No. 100A 4P MCCB Microprocessor based of fault breaking capacity 25KA (Ics=Icu) upto 500V manually operated and with inbuilt S/C & O/C protection relay , extended rotary handle for door interlock with Phase spreaders & Phase Barriers at both sides. ( For Solar supply input) Mechnical & Electrical interlocking between both incomers. CTs, METERING & INDICATIONS 1 Set of R,Y,B phase Indication lamps controlled with control MCB's. with each incomer. Provide 1Set indicating lamps for status indication "ON","OFF" , tripped due to Earth leakage with each incomer except incomer for solar CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, Harmonics, Memory 2MB, HT/LT selectable, USB port, RS-485 Port, LCD display, 4 relay output for all incomers with class - 0.5 accuracy. 1 No. 30-3000mA ELR with tape wound CBCT each for all incomer except solar as shown in SLD.

-

-

-

... More
BUS BARS 250Amps 4P, 25kA, 500volts grade busbar chamber of suitable length with aluminium busbars. All interconnections shall be with aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for aluminium cross sectional area of Bus Bar. OUTGOINGS 2 Nos. 100A 4P MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 6 Nos. 63A, 10kA, 4P MCB with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 12 Nos. 32A, 10kA, 4P MCB with CT-Operated Trinity Make- NF29 or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. 6 Nos. 63A, 10kA, 4P MCB 2 Nos. 32A, 10kA, DP MCB 2 Sets of 1 No. 25A, 10kA, 4P MCB + 1 No. 25A, TP Contactor with

-

-

-

... More
Auto/Manual Selector Switch, Start/Stop push button, on/off/Trip indications with control MCB. 2 Nos. Astronomical time switches with in- built minimum 5 years battery back up and USB keys. Conform to IEC 60730, Operating voltage : 230V, 50Hz, Hager make-EE181 or Eq. Make. Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. Necessary Mounting MS stand of 300mm height with 2 Nos of coating of anti corrision paint and 1 No. Final coating of black paint. The cost shall include here.

-

-

-

... More
SDB-4 (ESSENTIAL PANEL) BLOCK TYPE-V as described above.

1

-

-

... More
MDB (BLOCK Type-VII) Outdoor Use-IP:65. Incoming: 2 Nos. 200A 4P MCCB built in microprocessor based release (adjustable O/L, S/C & E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. Mechnical & Electrical interlocking between both incomers. CTs, METERING & INDICATIONS 1 Set of R,Y,B phase Indication lamps controlled with control MCB's. with each incomer. Provide 1Set indicating lamps for status indication "ON","OFF" , tripped due to Earth fault for all incomer MCCB with each incomer CT-Operated Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kwH, kVAH (EB & DG), LCD display for all incomers with class - 0.5 accuracy. Bus Bars 250Amps 4P, 25kA, 500volts grade busbar chamber of suitable length with aluminium busbars. All interconnections shall be with aluminium Bus-bars, current density of bus-bars shall not be less than 1.3 Amps/sq.mm for aluminium cross sectional area of Bus Bar.

-

-

-

... More
Outgoings 6 Nos. 63A 4P MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended. with CT-Operated dual source Trinity Make- TINY PRO 6 - DUAL or equivalent Multi Function Panel mounted Meter - (96 mm x 96 mm) covering voltage, ampere, frequency, power factor, kW, kVA, kVAR, kWH, kVAH, kVARH, RS-485 Port, LCD display with class - 0.5 accuracy. Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. Necessary Mounting MS stand of 600mm height with 2Nos of coating of anti corrision paint and 1No. Final coating of black paint. The cost shall include here.

-

-

-

... More
MDB (BLOCK Type-VII) Outdoor Use-IP:65. as described above .

1

-

-

... More
COMMON SERVICES

-

-

-

... More
EXTERNAL LIGHT PANEL EX-1 (OUTDOOR IP:65) INCOMER 1 No. Fixed type Automatic transfer switch, 63A, 300 series, 4P ATS with overlapping neutral in open frame with live to live transfer time 70ms. It should be confirming to AC-33A/33iA utilization category. The ATS should have complete overlapping neutral with In phase monitor. The controller should be microprocessor based with tested EMC/EMI or as per UL-1008. 1 No. of 63 Amp 4P MCB of 10 KA Breaking capacity CTs, METERING & INDICATIONS R,Y,B phase indication lamps with 6A Control MCB as per fault requirement for each incomer 1 Set of Auto/Manual Selector Switch, Start/Stop push button, on/off/Trip indication with each contactor BUS BARS Section-1,2, 3 ( For R,Y, B Phase) 100 amps, 16kA, 480volts grade busbar chamber of suitable length with copper busbars. All busbars and interconnections shall be of suitable size copper busbar, current density of bus-bars shall not be less than 1.6 Amps / sq.mm cross sectional area of Bus Bar provide 100% capacity for neutral bus bar. OUTGOINGS 3 Nos. 63 amp DP 300mA RCCB 3 Nos. 63A, DP Contactor with Astronomical time switches with in- built minimum 5 years battery back up and USB keys. Conform to IEC 60730, Operating voltage : 230V, 50Hz.. 36 Nos. 10-25 amp SP MCB of 10 kA breaking capacity. All MCB's chambers shall have Acrylic sheet infront. Necessary Mounting MS stand of 600mm height with 2 Nos of coating of anti corrision paint & 1 No. final coating of black paint. The cost shall include here.

-

-

-

... More
EXTERNAL LIGHT PANEL EX-1 (OUTDOOR IP:65) (described as above)

1

-

-

... More
EXTERNAL LIGHT PANEL EX-2 (OUTDOOR IP:65) INCOMER 1 No. Fixed type Automatic transfer switch, 63A, 300 series, 4P ATS with overlapping neutral in open frame with live to live transfer time 70ms. It should be confirming to AC-33A/33iA utilization category. The ATS should have complete overlapping neutral with In phase monitor. The controller should be microprocessor based with tested EMC/EMI or as per UL-1008. 1 No. of 63 Amp 4P MCB of 10 KA Breaking capacity. CTs, METERING & INDICATIONS R,Y,B phase indication lamps with 6A Control MCB as per fault requirement for each incomer. 1 Set of Auto/Manual Selector Switch, Start/Stop push button, on/off/Trip indication with each contactor. BUS BARS Section-1,2, 3 ( For R,Y, B Phase) 100 amps, 16kA, 480volts grade busbar chamber of suitable length with copper busbars. All busbars and interconnections shall be of suitable size copper busbar, current density of bus-bars shall not be less than 1.6 Amps / sq.mm cross sectional area of Bus Bar provide 100% capacity for neutral bus bar. OUTGOINGS 3 Nos. 63 amp DP 300mA RCCB 3 Nos. 63A, DP Contactor with Astronomical time switches with in- built minimum 5 years battery back up and USB keys. Conform to IEC 60730, Operating voltage : 230V, 50Hz. 23 Nos. 10-25 amp SP MCB of 10 kA breaking capacity All MCB's chambers shall have Acrylic sheet infront Necessary Mounting MS stand of 600mm height with 2Nos of coating of anti corrision paint and 1No. Final coating of black paint. The cost shall include here.

-

-

-

... More
EXTERNAL LIGHT PANEL EX-2 (OUTDOOR IP:65) (described as above)

1

-

-

... More
EXTERNAL LIGHT PANEL EX-3 (OUTDOOR IP:65) INCOMER 1 No. Fixed type Automatic transfer switch, 63A, 300 series, 4P ATS with overlapping neutral in open frame with live to live transfer time 70ms. It should be confirming to AC-33A/33iA utilization category. The ATS should have complete overlapping neutral with In phase monitor. The controller should be microprocessor based with tested EMC/EMI or as per UL-1008. 1 No. of 63 Amp 4P MCB of 10 KA Breaking capacity CTs, METERING & INDICATIONS R,Y,B phase indication lamps with 6A Control MCB as per fault requirement for each incomer 1 Set of Auto/Manual Selector Switch, Start/Stop push button, on/off/Trip indication with each contactor. BUS BARS Section-1,2, 3 ( For R,Y, B Phase) 100 amps, 16kA, 480volts grade busbar chamber of suitable length with copper busbars. All busbars and interconnections shall be of suitable size copper busbar, current density of bus-bars shall not be less than 1.6 Amps / sq.mm cross sectional area of Bus Bar provide 100% capacity for neutral bus bar. OUTGOINGS 3 Nos. 63 amp DP 300mA RCCB 3 Nos. 63A, DP Contactor with Astronomical time switches with in- built minimum 5 years battery back up and USB keys. Conform to IEC 60730, Operating voltage : 230V, 50Hz. 30 Nos. 10-25 amp SP MCB of 10 kA breaking capacity All MCB's chambers shall have Acrylic sheet infront Necessary Mounting MS stand of 600mm height with 2 Nos of coating of anti corrision paint & 1 No. final coating of black paint. The cost shall include here.

-

-

-

... More
EXTERNAL LIGHT PANEL EX-3 (OUTDOOR IP:65) (described as above)

1

-

-

... More
PLUMBING PANEL (Indoor use on a plain civil foundation with cable entry from top) INCOMER 2 Nos.100A TP+NL MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. BUS-COUPLER 1 No.100A 4P MCCB built in microprocessor based release (adjustable O/L,S/C&E/F) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. Mechnical & Electrical interlocking between both Main incomers and coupler METERING, INDICATOR AND RELAYs Provide 3 Nos. Resin cast CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements A,V,Hz and RS-485 port for BMS with class-1.0 accuracy for all outgoing feeder. E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer. Provide 3 Nos indicating lamps for status indication "ON","OFF" , Tripped due to earth fault on each incomer TVSS AND BUS BARS 230 Amps TP+N, 25kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be with FRLS PVC insulated copper flexible colour coded wires, current density of bus-bars shall not be less than 1 Amps/sq.mm for Aluminium and 2 Amps/sq.mm for copper cross sectional area of Bus Bar.

-

-

-

... More
Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O. OUTGOINGS Note:- 1. All Starters shall be High Performance Star Delta / DOL Motor Starters as specified (Type 2 Co-ordination with MPCB at 415 V) 2. Necessary port/devices for connection and operation from remote location by BMC/Scada. 1 Set of TP MPCB with inbuilt over load relay, SPP of 50kA breaking capacity each with 5.5HP DOL motor starter type ii co-ordination along with TP power contactors (AC3 Duty) with inbuilt 2NO + 2NC contact, Analouge Ammeter with selector switch, Red, Green & Yellow Indicating Lamps each with control SP Fuse, Start/Stop Push buttons, Auto/Manual/off selector switch, 230Vac, 0-30 Second and SPP Complete as required, for 3Nos. Filter Feed Pumps (2 Working +1 Stand-by).

-

-

-

... More
1 Set of TP MPCB with inbuilt over load relay, SPP of 50 KA breaking capacity each with 15.0HP Star-Delta motor starter type ii co-ordination along with 3 Nos. TP power contactors (AC3 Duty) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor, Analogue Ammeter with selector switch, Red, Green & Yellow Indicating Lamps each with control SP HRC Fuse, Start/Stop Push buttons, Auto/Manual/off selector switch, Timer, 230Vac, 0-30Second and SPP Complete as required, For 3Nos. Domestic water transfer Pumps ( 2 Working +1 Stand-by ). Provide Sequance Controller / Micro PLC in between starter feeders working and stand-by. The scheme for starting the pumps shall be such that only one Pump shall start at a time and the sequence of starting the pumps shall change regularly on daily basis and The pump shall srart on receiving the signal from pump controller. 1 No. 32A TPN 'B' CURVE MCB for outgoing external Sump Pump Starter 2 H.P.

-

-

-

... More
PLUMBING PANEL as described above.

1

-

-

... More
H.T./ L.T./ CONTROL CABLES

-

-

-

... More
SUPPLY OF ALUMINIUM ARMOURED CABLES: Supply of following sizes of 1.1 kV grade multistranded aluminium conductor armoured, XLPE insulated, PVC tape/ extruded inner & outer sheathed FRLS, power cable as per IS:7098 (Part 1) amended upto date as per approved GTP.

-

-

-

... More
(a) 4 CORES 16 sq.mm.

13399

-

-

... More
(b) 4 CORES 25 sq.mm.

2206

-

-

... More
(c) 3.5 CORES 35 sq.mm.

150

-

-

... More
(d) 3.5 CORES 70 sq.mm.

704

-

-

... More
(e) 3.5 CORES 95 sq.mm.

100

-

-

... More
(f) 3.5 CORES 120 sq.mm.

451

-

-

... More
(g) 3.5 CORES 150 sq.mm.

649

-

-

... More
(h) 3.5 CORES 185 sq.mm.

1120

-

-

... More
(j) 3.5 CORES 240 sq.mm.

3665

-

-

... More
(k) 3.5 CORES 300 sq.mm.

1484

-

-

... More
(l) 3.5 CORES 400 sq.mm.

1128

-

-

... More
SUPPLY OF COPPER ARMOURED CABLES: Supply of following sizes of Power Cables, multi stranded copper conductor, XLPE Insulated, cores laid up, PVC tape / Extruded Inner sheathed, Armoured, FRLS at outer sheathed,1100V grade as per IS 7098(Part 1) 1988 as per approved GTP.

-

-

-

... More
(a) 2 CORES 6 sq.mm.

400

-

-

... More
(b) 4 CORES 6 sq.mm.

2716

-

-

... More
(c) 4 CORES 10 sq.mm.

3609

-

-

... More
SUPPLY OF CONTROL CABLE Supply of following sizes of Control Cables, Solid Copper conductor single stranded conductor, FRLS Insulated inner/external, cores laid up, PVC tape / Extruded Inner sheathed, Glavanised round wire armour, extruded PVC Type ST2 sheathed, 650V grade as per approved GTP.

-

-

-

... More
(a) 6CX1.5 Sqmm

135

-

-

... More
(b) 10CX1.5 Sqmm

176

-

-

... More
SUPPLY OF 11 kV H.T. CABLE Supply of 11kV (E) 3Core 240 sq. mm Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape (0.2kA for 1 sec/Core), cores laid up, innersheath/Outer of FRLS PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments as per approved GTP.

1840

-

-

... More
LAYING OF LT/ CONTROL CABLES Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
(a) Upto 35 sq. mm

1918

-

-

... More
(b) Above 35 sq. mm and upto 95 sq. mm

241

-

-

... More
(c) Above 95 sq. mm and upto 185 sq. mm

666

-

-

... More
(d) Above 185 sq. mm and upto 400 sq. mm

1883

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.

-

-

-

... More
(a) Upto 35 sq. mm (clamped with 1mm thick saddle)

2877

-

-

... More
(b) Above 35 sq.mm & upto 95 sq.mm (clamped with 25x3mm MS flat clamp)

402

-

-

... More
(c) Above 95 sq.mm & upto 185 sq.mm (clamped with 25/40x3mm MS flat clamp)

1110

-

-

... More
(d) Above 185 sq.mm & upto 400 sq.mm (clamped with 40x3mm MS flat clamp)

3139

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.

-

-

-

... More
(a) Upto 35 sq. mm

2877

-

-

... More
(b) Above 35 sq. mm and upto 95 sq. mm

121

-

-

... More
(c) Above 95 sq. mm and upto 185 sq. mm

333

-

-

... More
(d) Above 185 sq. mm and upto 400 sq. mm

942

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc. as required including sand cushioning and protective covering.

-

-

-

... More
(a) Upto 35 sq. mm

2877

-

-

... More
(b) Above 35 sq. mm and upto 95 sq. mm

121

-

-

... More
(c) Above 95 sq. mm and upto 185 sq. mm

333

-

-

... More
(d) Above 185 sq. mm and upto 400 sq. mm

942

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cables of 1.1 kV grade of following size direct in ground in the same trench upto five tier horizontal and upto four tier vertical formation including excavation and refilling the trench etc. as required including sand cushioning and protective covering.

-

-

-

... More
(a) Upto 35 sq. mm

8632

-

-

... More
(b) Above 35 sq. mm and upto 95 sq. mm

362

-

-

... More
(c) Above 95 sq. mm and upto 185 sq. mm

999

-

-

... More
(d) Above 185 sq. mm and upto 400 sq. mm

2825

-

-

... More
HT CABLE LAYING

-

-

-

... More
Laying of one number XLPE power cable of 11 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm

177

-

-

... More
Laying of one number XLPE power cable of 11 kV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm

75

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq. mm and upto 400 sq. mm

1497

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq. mm and upto 400 sq. mm

166

-

-

... More
TERMINATIONS FOR LT ALUMINIUM CABLES Supplying and making end termination with brass Double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required

-

-

-

... More
(a) 4 x 16 sq. mm (28mm)

622

-

-

... More
(b) 4 x 25 sq. mm (28mm)

52

-

-

... More
(c) 3½ x 35 sq. mm (32mm)

4

-

-

... More
(d) 3½ x 70 sq. mm (38mm)

4

-

-

... More
(e) 3½ x 95 sq. mm (45 mm)

4

-

-

... More
(f) 3½ x 120 sq. mm (45mm)

12

-

-

... More
(g) 3½ x 150 sq. mm (50 mm)

20

-

-

... More
(h) 3½ x 185 sq. mm (57mm)

16

-

-

... More
(j) 3½ x 240 sq. mm (62mm)

34

-

-

... More
(k) 3½ x 300 sq. mm (62mm)

30

-

-

... More
(l) 3½ x 400 sq. mm (62mm)

28

-

-

... More
TERMINATIONS FOR LT COPPER CABLES Supplying and making end termination with brass Double compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

-

-

-

... More
(a) 2C x 6 sq. mm

6

-

-

... More
(b) 4C x 6 sq. mm

100

-

-

... More
(c) 4C x 10 sq. mm

74

-

-

... More
TERMINATIONS FOR CONTROL CABLE Supplying and making indoor Control Cable end Termination of following sizes 650V grade LT XLPE insulated, HR PVC sheathed, stranded copper conductor, Armoured cables, including cost of tinned copper heavy duty crimpping lugs, Single compression heavy duty glands, insulation tape, Name Plate at Both Ends and all necessary material to complete the termination.

-

-

-

... More
(a) 6Cx1.5 Sqmm

10

-

-

... More
(b) 10Cx1.5 Sqmm

12

-

-

... More
TERMINATION FOR 11kV H.T CABLE Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. a) 240 sq. mm

22

-

-

... More
STRAIGHT THROUGH JOINTS FOR HT CABLES Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. a) 240 sq. mm

2

-

-

... More
Providing, laying and fixing following dia RCC pipe NP4 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (not less than 90 cm deep) and refilling etc. as required.

-

-

-

... More
(a) 250 mm dia

322

-

-

... More
(b) 300 mm dia

1000

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. including trenching (not less than 90 cm deep) and refilling etc. as required.

-

-

-

... More
(a) 63 mm dia (OD-63 mm & ID-51 mm nominal)

9751

-

-

... More
(b) 90 mm dia (OD-90 mm & ID-76 mm nominal)

1500

-

-

... More
(c) 200 mm dia (OD-200 mm & ID-175 mm nominal)

3850

-

-

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

60

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

80

-

-

... More
EARTHING SYSTEM

-

-

-

... More
Earthing with hot dipped G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as per IS:3043 latest as on date as required.

32

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc with charcoal/ coke and salt as per IS:3043 latest as on date as required.

22

-

-

... More
Supply, installation, testing and commissioning of Copper Bonded Rod earthing (Dia-17.2 mm, Length-3000mm) 250 micron Copper coating with clamp and 50 kg BFC (Eric/JAM Fill) complete in all respects. (The installation procedures should be followed as instructed by the Earth Electrode supplier). The Earth pit should be covered with heavy duty Polyplastic weather proof chamber. (The resistance value shall be guranteed for less then 1ohm for minimum 1 years without any maintenance) The product should meet the requirements as per IEC or any equivalent international specification (UL). Chemicals used shall be environmental friendly.

44

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

228

-

-

... More
Providing and fixing 25 mm X 5 mm hot dipped G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

1538

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

176

-

-

... More
Providing and fixing 25 mm X 5 mm hot dipped G.I. strip on surface or in recess for connections etc. as required.

10385

-

-

... More
Providing and fixing 32 mm X 6 mm hot dipped G.I. strip in 50 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

28

-

-

... More
Providing and fixing 32 mm X 6 mm hot dipped G.I. strip on surface or in recess for connections etc. as required.

28

-

-

... More
Providing and fixing 50 mm X 6 mm copper strip in 80 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

100

-

-

... More
Providing and fixing 50 mm X 6 mm copper strip on surface or in recess for connections etc. as required.

77

-

-

... More
Providing and fixing 50 mm X 6 mm hot dipped G.I. strip in 80 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

264

-

-

... More
Providing and fixing 50 mm X 6 mm hot dipped G.I. strip on surface or in recess for connections etc. as required.

363

-

-

... More
Providing and fixing 6 SWG dia hot dipped G.I. wire on surface or in recess for loop earthing as required.

3960

-

-

... More
HOT DIPPED GALVANIZED IRON CABLE TRAY Hot Dipped Galvanized Iron Cable Tray Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 80 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including necessary bends,Tee, reducers etc and G.I. bolts & nuts, etc. as required. as per IS code 2629-1985.

-

-

-

... More
(a) 750 mm width x 62.5 mm depth x 2.0 mm thickness ( 9.9kG/m)

41

-

-

... More
(b) 600 mm width x 62.5mm depth x 2.0 mm thickness ( 8.1kG/m)

84

-

-

... More
(c) 450 mm width x 62.5 mm depth x 2.0 mm thickness ( 6.3kG/m)

363

-

-

... More
(d) 300 mm width x 50 mm depth x 1.6 mm thickness ( 4.5kG/m)

23

-

-

... More
(e) 150 mm width x 50 mm depth x 1.6 mm thickness ( 3kG/m)

570

-

-

... More
(f) 100 mm width x 50 mm depth x 1.6 mm thickness ( 2.5kG/m)

86

-

-

... More
SAFETY EQUIPMENTS Supply and Erection of MS angle iron bucket stand which include 6 Nos. fire bucket with 9 ltr. Capacity with sand filling including cost of fabrication, welding and painting of complete stand & buckets with one coat of red oxide and two coats of approve paint of red color written with fire on the buckets as per fire protection with all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work.

4

-

-

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 3mm thick, suitable for 11 KV , fire retardant, no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .

15

-

-

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 2mm thick, suitable upto 3.3 KV , fire retardant, no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .

74

-

-

... More
Supply and fixing in position approved shock treatment chart written in English, Hindi and local language. These charts shall be framed in wooden frame and covered with clear glass.

3

-

-

... More
Supply of First aid box as approved by St. John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963.

2

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

24

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
Supplying of Rubber gloves of 11 KV grade as per IS 4770-68.

1

-

-

... More
Supplying and fixing of MS sheet board of size 500mm x 300mm of 16 SWG with 'Entry Restricted to Authorised Person Only" near the main entrance of the Sub- Station. The lettering shall be black painted on yellow base or as approved by engineer incharge.

3

-

-

... More
Supplying and fixing of MS chequered plate 5mm thick as approved by engineer incharge. SAFETY EQUIPMENTS described as above.

75

-

-

... More
25kW SOLAR SYSTEM (1 No. For each OR Block, 1 No. For JCO Block and 1 No. For Each Type V Block) Supplying, installation, testing & commissioning of On grid interactive roof top solar photo voltaic power generation system I/C space frame including accessories such as MC4 connectors, cable lugs, ties, thimbles, etc. as described below: i) 80 Nos. Poly crystalline Silicon Solar Photo Voltaic Modules of 310 Wp @ STC ii) 1 Set Module Mounting MS Structure, Suitable to Mount 25 KWp Solar Modules iii) 1 No. Grid Tie Inverter of 25kVA rating iv) 1 Set AC & DC cables of appropriate rating and length as per requirement. v) 1 No. Lightning Arrestor vi) Miscellanious items like Cable lugs, Ties, cable trays (if required), Earthing strips, MC4 connector pairs, thimbles, conduits etc.

7

-

-

... More
EXTERNAL LIGHTING WORKS

-

-

-

... More
Supplying & erection of 4.5 m MS pole with 35-55 micron Anti rust coating & PU (PolyUrethane) Painted, the pole coating includes red oxide, plaster and PU synthetic paint coatings in 2 layers. The pole shall be-3.0mm thick with 60 mm outer dia with 4 nos of GI. founadation nut & bolt (20mm dia & 200mm long) with a base plate of 250mm X 250mm, Base Plate thickness- 15 mm, 2Nos Template complete as required. (Note: The foundation for poles shall be provided by civil contractor).

144

-

-

... More
Supply, installation, testing, commissioning and numbering of outdoor type LED Solar street light hybrid type with dimming and PIR sensor, 12V inbuilt Solar PV Module, intergrated charger and driver with total system wattage 15-20W, high pressure die cast aluminium housing, including arms as per requirement and Li Batteries with enclosure and mounting arrangement, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED is to be provided with individual lense optics to get optimum Optical performance, with IP-65, fixture should have minimum efficacy =175 lm/W and minimum system lumens 3000. ( similar to Philips cat Ref : BRP710 LED 30 CW MR S1 12V LFP AIO Solar Equip IN or equivalent)

159

-

-

... More
Supplying & erection of 6 m MS pole with 35-55 micron Anti rust coating & PU (PolyUrethane) Painted, the pole coating includes red oxide, plaster and PU synthetic paint coatings in 2 layers. The pole shall be-3.0mm thick with 60 mm outer dia with 4 nos of GI. founadation nut & bolt (25mm dia & 250mm long) with a base plate of 300mm X 300mm, Base Plate thickness- 15 mm, 2Nos Template complete as required. (Note: The foundation for poles shall be provided by civil contractor)

13

-

-

... More
Supplying and fixing of 40 mm dia X 1.5 meter long G.I. pipe (medium class) bracket for mounting of LED street light & flood light fitting including bending the pipe to the required shape, 2 Nos. 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.

157

-

-

... More
Supplying and fixing of Outdoor type thermoplastic junction box (enclosure) with lockable hinged double door, including 25x5mm thick M.S. painted clamps for mounting on pole of 60mm OD pole dia with 25A 4P Terminals, 10A SP C Curve MCB (10kA) and 2Nos. earth stud complete as required.

144

-

-

... More
Supplying and fixing of Outdoor type thermoplastic junction box (enclosure) with lockable hinged double door, including 25x5mm thick M.S. painted clamps for mounting on pole of 60mm OD pole dia with 25A 4P Terminals, 10A DP C Curve MCB (10kA) and 2Nos. earth stud complete as required.

6

-

-

... More
Supplying and fixing of Outdoor type thermoplastic junction box (enclosure) with lockable hinged double door, including 25x5mm thick M.S. painted clamps for mounting on pole of 60mm OD pole dia with 25A 4P Terminals, 10A TP C Curve MCB (10kA) and 2Nos. earth stud complete as required.

6

-

-

... More
Supplying and fixing of Outdoor type thermoplastic junction box (enclosure) with lockable hinged double door, including 25x5mm thick M.S. painted clamps for mounting on pole of 60mm OD pole dia with 25A 4P Terminals, 10A 4P C Curve MCB (10kA) and 2Nos. earth stud complete as required.

1

-

-

... More
Supplying and fixing of outdoor type weather proof Thermoplastic connector box with suitable connectors for connecting upto 3CX2.5Sqmm Cu. Flexible wire complete as required.

94

-

-

... More
Supply, installation, testing, commissioning and numbering of 8.5W, LED Bollard with luminaire & efficacy ≥ 60 lm/W, CRI 70, THD≤10%, high pressure die cast aluminium/ standard alloy housing with top cover and semless GI pipe bottom housing for control gear and luminaire to be provided with base plate and fixing holes for directly mounting on the concrete pedestal, IP ≥ 65, surge protection ≥ 10kv, PF ≥ 0.95, total power consumption of the fixture shall not more than 110% of the rated capacity of the fixutre, with prewired electronic driver complete with all accessories suitable for operation on single phase 170-270V 50Hz AC supply as required. (Similar to Philips Cat No. BCP400 LED09 D CW PSU GR S1 or equivalent.).

274

-

-

... More
Supply, installation, testing, commissioning and numbering of 150W, LED flood Light & efficacy ≥ 100 lm/W, CRI 70, THD≤10%, high pressure die cast aluminium/ standard alloy housing, IP ≥ 65, surge protection ≥ 10kv, PF ≥ 0.95, with adjustible beam angle, total power consumption of the fixture shall not more than 110% of the rated capacity of the fixutre, with prewired electronic driver complete with all accessories suitable for operation on single phase 170-270V 50Hz AC supply as required. (Similar to Philips Cat No. BVP410 LED 172 CW HE NB FG S3 XT or equivalent )

40

-

-

... More
Supply, installation, testing, commissioning and numbering of 15.8W, LED Uplighter Light & efficacy ≥ 70 lm/W, CRI 70, THD≤10%, high pressure die cast aluminium/ standard alloy housing, IP ≥ 65, surge protection ≥ 10kv, PF ≥ 0.95, with adjustible beam angle, total power consumption of the fixture shall not more than 110% of the rated capacity of the fixutre, with prewired electronic driver complete with all accessories suitable for operation on single phase 170-270V 50Hz AC supply as required. (Similar to Philips Cat No. LED Uplite BBP330 or equivalent )

24

-

-

... More
Supply, installation, testing, commissioning and numbering of recessed mount 4W, LED step Light & CRI 70, THD≤10%, high pressure die cast aluminium/ standard alloy housing, IP ≥ 65, surge protection ≥ 10kv, PF ≥ 0.95, total power consumption of the fixture shall not more than 110% of the rated capacity of the fixutre, with prewired electronic driver complete with all accessories suitable for operation on single phase 170-270V 50Hz AC supply as required. (Similar to Philips Cat No. BGW 150 LED or equivalent ).

74

-

-

... More
WIRING

-

-

-

... More
Wiring for First light point/ fan point/ exhaust fan point/ call bell point (wiring from switch board to first point) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy duty minimum 2.0mm thick FRLS PVC conduit as per IS:9537 Part-3 latest as on date, include the cost of SITC of modular switch & modular plate, suitable minimum 0.8mm thick GI box (Similar to Legrand- Britzy or equivalent from Approved list of Make) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C

49

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed heavy duty minimum 2.0mm thick FRLS PVC conduit as per IS:9537 Part-3 latest as on date, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C

87

-

-

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy duty minimum 2.0mm thick FRLS PVC conduit as per IS:9537 Part-3 latest as on date as required

-

-

-

... More
(a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire

253

-

-

... More
(b) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire

6597

-

-

... More
(c) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire

650

-

-

... More
(d) 2 x 6 sq. mm + 1 x 6 sq. mm earth wire

100

-

-

... More
(e) 4 x 6 sq. mm + 2 x 6 sq. mm earth wire

50

-

-

... More
(f) 4 x 10 sq. mm + 2 x 6 sq. mm earth wire

100

-

-

... More
(g) 4 x 16 sq. mm + 2 x 6 sq. mm earth wire

50

-

-

... More
Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed heavy duty minimum 2.0mm thick FRLS PVC conduit as per IS:9537 Part-3 latest as on date as required. a) 3 x 1.5 sq. mm

816

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

53

-

-

... More
Supplying and fixing of following sizes of heavy duty minimum 2.0mm thick FRLS PVC conduit as per IS:9537 Part-3 latest as on date along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
(a) 25 mm

1696

-

-

... More
(b) 32 mm

848

-

-

... More
(c) 50 mm

6852

-

-

... More
Supplying and fixing minimum 0.8mm thick GI box of following sizes (nominal size) on surface or in recess with suitable size of 3mm thick phenolic laminated sheet cover in front including painting etc. as required.

-

-

-

... More
(a) 100 mm x 100 mm x 60 mm deep

2

-

-

... More
(b) 200 mm x 150 mm x 60 mm deep

2

-

-

... More
Supplying and fixing following modular socket outlets on the existing modular plate & switch box (Similar to Legrand- Britzy or equivalent from Approved List of Make) including connections etc. as required.

-

-

-

... More
(a) Telephone socket RJ-45 outlet

11

-

-

... More
(b) TV antenna socket outlet

2

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate & switch box (Similar to Legrand- Britzy or equivalent from Approved List of Make) including connections but excluding modular plate etc. as required.

10

-

-

... More
Supplying and fixing 1 or 2 Module (75 mmx75 mm) size/ modules, minimum 0.8mm thick GI box alongwith modular base & cover plate for modular switches/ Telephone/ TV/ CCTV outlet (Similar to Legrand- Britzy or equivalent ) in recess etc. as required.

13

-

-

... More
Supplying and fixing suitable size minimum 0.8mm thick GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 6 A modular shuttered socket outlet and 6 A modular switch (Similar to Legrand- Britzy or equivalent ), connections etc. as required.

18

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 6 A modular socket outlet and 2 Nos. 6 A modular switch (Similar to Legrand- Britzy or equivalent from Approved List of Make), connections etc. as required.

20

-

-

... More
Supplying and fixing suitable size minimum 0.8mm thick GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 6/16 A modular shuttered socket outlet and 16 A modular switch (Similar to Legrand- Britzy or equivalent from Approved List of Make), connections etc. as required.

21

-

-

... More
Supplying and fixing 3 pin, 6A ceiling rose on the existing junction box including connections etc. as required.

3

-

-

... More
Supplying & fixing suitable size minimum 0.8mm thick GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular switch (Similar to Legrand- Britzy or equivalent from Approved List of Make) including connections, painting etc. as required.

8

-

-

... More
DISTRIBUTION BOARDS

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel thickness minimum 1.2mm, prewired MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated short link,interconnections, powder painted (minimum 60-80 micron) including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make Similar to :- Legrand or equivalent from Approved List of Make) a) 12 way, Double door

2

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel thickness minimum 1.2mm, MCB Prewired distribution board, 415 V, on surface/ recess, complete with 3Nos. tinned copper bus bar (For three phase, 4 Nos. neutral bus bar (For three phase & One common), 3 Nos. earth bar, din bar, insulated short links one per phase, interconnections, powder painted (minimum 60-80 micron) including earthing etc. as required. (But without MCB/RCCB/ Isolator) (Make Similar to :- Legrand or equivalent ). a) 8 way (4 + 24), Double door

3

-

-

... More
Supplying and fixing following rating, 240/415 V, C curve 6kA MCB (Suitable for isolation) in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
(a) 6-32A (Single Pole)

73

-

-

... More
(b) 6-32A (Double Pole)

2

-

-

... More
(c) 40 A (Four Pole)

3

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

4

-

-

... More
Supplying and fixing following rating, 240/415 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
(a) 25 A (Double Pole)

2

-

-

... More
(b) 40 A (Double Pole)

10

-

-

... More
Supplying and fixing Loose wire box (IP 43) suitable for following single pole and neutral, minimum 1.2mm thick sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. a) For 12 way, Double door SPN MCBDB

2

-

-

... More
Supplying and fixing Loose wire box (IP 43) suitable for following triple pole and neutral, minimum 1.2mm thick sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. a) For 8 way, Double door TPN MCBDB

3

-

-

... More
LIGHT FIXTURES AND FANS Supply, installation, testing, commissioning and numbering of indoor type surface mounted Linear LED fitting white CRCA powder coated with total system wattage 18-20W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflecctor, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED shall be SMD type, fixture should have minimum efficacy =100 lm/W and minimum system lumens 2000. Similar to PHILIPS-BN021 LED 20S PSU CDLGR/Trilux or equivalent make as per approved list of make.

79

-

-

... More
Supply, installation, testing, commissioning and numbering of indoor type surface mounted downlighter white CRCA powder coated LED light fixture with total system wattage 18-20W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflecctor, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED shall be SMD type, fixture should have minimum efficacy =110 lm/W and minimum system lumens 2000. Similar to Philips-SM251C LED 20S-6500 PSU WH/Trilux or equivalent make as per approved list of make.

6

-

-

... More
Supply, installation, testing, commissioning and numbering of LED Bulkhead luminaire, Vandal resistant Polycarbonate diffuser with IP 65, IK08 dust tight and water Jet proof for clean operation with total system wattage 9-10W and system lumen 600 lm, luminaire efficiency of luminaire not less than 55 lm/w.

21

-

-

... More
Supply, installation, testing, commissioning and numbering of 5 star rated 1200mm sweep ceiling fan, ISI marked, along with copper wound stator, blades, capacitor, downrod, split pin, reel but without regulator complete as required.

10

-

-

... More
Supply, installation, testing, commissioning and numbering of 240 Volt single phase 900 rpm heavy duty IS mark 250mm sweep PVC exhaust fans with lovers with bird guard complete as required. Similar to Havells-VENTIL AIR DX or equivalent as per approved list of make.

3

-

-

... More
Supply, installation, testing, commissioning and numbering of surface mounted high performance, Movement cum Presence Detector with the coverage of min. 4Mx3.5M-presence / 13Mx7M-movement at 2.5mtrs height with suitable base box including connection etc. complete as required.

6

-

-

... More
UPS Supply, installation, testing and commissioning of 10kVA, 1 Phase input and 1 Phase output UPS along 20 Nos. of 65AH Batteries @240 VDC with lead acid Sealed Maintenance Free batteries giving a back up of minimum 30min. at full load as per specification along with inbuit over voltage protection and all accessories including interconnecting cables, lugs, Base Frames, Battery Rack & Battery Circuit breaker complete as required.

1

-

-

... More
Supply, installation, testing and commissioning of 600VA, 1 Phase input and 1 Phase output UPS along with 12V, 7ah, 1 Lithium ion batteries giving a back up of minimum 10-15min. at 80% load as per specification along with inbuit over voltage protection and all accessories complete as required.

12

-

-

... More
TELEPHONE SYSTEM Supply, laying, testing & commissioning including termination at both ends and ferruling of following sizes of 0.5 mm dia tinned Copper conductor, PVC insulated, sheathed, Jelly filled armoured telephone cables.

-

-

-

... More
(a) 10 pair cable/ 0.5mm dia Jelly filled armoured.

2932

-

-

... More
(b) 20 pair cable/ 0.5mm dia Jelly filled armoured.

11

-

-

... More
(c) 30 pair cable/ 0.5mm dia Jelly filled armoured.

303

-

-

... More
(d) 50 pair cable/ 0.5mm dia Jelly filled armoured.

1096

-

-

... More
(e) 100 pair cable/ 0.5mm dia Jelly filled armoured.

3861

-

-

... More
KRONE BOX Supply, installation, testing & commissioning of telephone tag blocks with 'KRONE" terminal connectors fixed in 16G powder coated, hinged, lockable door, minimum 1.2mm thick sheet steel enclosure including civil work such as chase cutting, fixing / concealing the box and making good as required including termination.

-

-

-

... More
(a) 10 pair tele tag block

9

-

-

... More
(b) 50 pair tele tag block

1

-

-

... More
(c) 500 pair tele tag block

1

-

-

... More
Supplying and drawing of UTP 4 pair 23 AWG CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair CAT6 Unshielded, Twisted Pair (U/UTP) Cable. Blue/Orange/White/Green in colour conforming to the following standards like ANSI EIA/TIA 568 C.2, EN50173, IEC 11801 3rd ED, frequency tested upto 700Mhz with Third Party Certificate etc. Cable Dia 6.1 ± 0.3, Cross-member (+) fluted Spine/isolator for uniform separation for all pairs.

264

-

-

... More
FIRE ALARM WORKS

-

-

-

... More
Addressable Fire Alarm Control Panel Supply, installation, testing & commissioning of Ul Listed Microprocessor based 1 loop capacity scope of future expansion, Networkable Analogue Addressable type fire alarm control panel .The panel shall be equipped with 20% spare capacity with each loop having a loading of 135 detectors and 135 devices in one loop, QWERTY Keypad for programming through Panel and 600 Character LCD Display.Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and for 2 hours during an emergency conditions as required. (UL 9th Edition Approved). The Panel shall have a Network Communication Module with true peer to peer Connectivity. All panels should be networked with each other.

1

-

-

... More
Fire Alarm Repeater Panel for Digitally Addressable Fire Alarm System Supply, Installation, testing and Commissioning of 6 Zone Repeater fire alarm control panel suitable for digitally addressable Fire Alarm panels, stand by SMF lead acid battery (suitable for 48 hours normal operation & after that min. 2 hour for full load operation), battery charger, battery box, 16X2 character LCD alpha numeric character display with accept / reset buttons for alarm.

1

-

-

... More
Fire Alarm Repeater Panel for Addressable Fire Alarm System Supply, Installation, Testing, commissioing of 6Loop 640 character display and Keypad networked repater panel. It should be active and should have all the functions of main panel.

1

-

-

... More
Addressable System Detector & Devices Supply, Installation, Testing & Commissioning of UL listed Analog Addressable type Self Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting base, LED, Address Switch, complete with MS Powder coated Junction Box for mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.

20

-

-

... More
Supply, installation, testing and commissioning of UL Listed Addressable type Manual Call Point (break glass type), enclosed in box with provision for cable or conduit coupling etc.complete in all respects as required by the standard specifications. The unit to be painted fire red outside, white inside and written 'In case of fire break glass'.

4

-

-

... More
Supply, Installation, Testing & Commissioning of Fault Isolator Module, complete with MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.

2

-

-

... More
Supply, installation, testing and commissioning of UL Listed Response Indicators outside the rooms for getting fire indications of detectors installed above false ceiling area / inside the rooms interconnecting to loop cable complete in all respects as required by the standard specifications.

9

-

-

... More
Supply, Installation, Testing & Commissioning of UL Listed Addressable Relay Module with Address Switch and all mounting accessories complete as required and Shall be complete with Pilot Relay for Tripping of Third Party Equipment, suitable for switching 5A/15A current through the Relay contacts , MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.

2

-

-

... More
Supply, Installation, Testing & Commissioning of UL listed Addressable Monitor Module with Adddress Switch and all mounting accessories, complete with MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.

2

-

-

... More
Supply, Installation, Testing & Commissioning of Ul Listed Surface mounted addressable type fully solid state circuitory dual tone Electronic speaker cum hooters with strobe lights of 110 Cd intensity as per all requirements of technical specifications & contracts works.

4

-

-

... More
Wiring for Fire Alarm Repater Panel Supplying and drawing 6 x 1.5 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing conduit/ Pipe as required.

3381

-

-

... More
Wiring for Fire Alarm System Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed heavy duty minimum 2.0mm thick PVC conduit as per IS:9537 Part-3 latest as on date as required. a) 2 x 1.5 sq. mm

240

-

-

... More
Video Wall of size 2400x2400mm Supply, installation (fixed install mounting), transport to site, loading, unloading, testing and commissioing of outdoor LED screen Pixel Pitch 4.81mm, UL Listed, Pixel Density 43264dots/sqm,Color Configuration SMD1921(RGB), LED Package SMD2121(RGB), Module Size 250mm x 250mm, Module Resolution 52dots x 52dots, Drive Mode 1/16 Scan, Cabinet made of die casting aluminum, Standard Cabinet Size 500mm x 1000mm, Cabinet Weight approx. 14KG, Brightness ≥4500 cd/sqm, Viewing Distance 8m-10m, Viewing Angle H: 120°; V:120°, Refresh Rate 1920HZ, Grey Scale 14bit, Color Temperature R.G.B brightness 256 level adjustable, Power Input AC: 220V ±10%, Max Power Consumption 720W/sqm,Ave. Power Consumption 216W/sqm,Working Temperature -10℃~+40℃, Blind Spot Rate 1/10000, Life Span 1,00,000 Hours, Waterproof Level IP:65, Control Method Synchronous, Asynchronous, 3G,WIFI,USB,Control PC With DVI, Operating System Win 98, Win2000, XP, Win7, Win8,Win10. Make : Barco or Equivalent.

2

-

-

... More
PART-N : CCTV & SECURITY SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of Dome Camera with 1/2.8” Progressive Scan CMOS, 4MP bullet, 2.8-12mm motorised lens, P-Iris, 2592x1520 @ 25fps, Triple stream, Sensitivity of Color 0.02 Lux @ F1.4 AGC ON, Smart IR LED range 30 mtr, Ture WRD, H.265/H.264 support, 2D/3D Noise reduction, IP66, Alarm1/1, Audio1/1, ROI, Defog, HLC, Corridor mode, DIS, SD card slot, BNC output FCC, CE, EN/UL certified, ONVIF profile S

2

-

-

... More
Supply, installation, testing and commissioning of Bullet Camera with 1/2.8” Progressive Scan CMOS, 4MP bullet, 2.8-12mm motorised lens, P-Iris, 2592x1520 @25fps, Triple stream, Sensitivity of Color 0.02 Lux @ F1.4 AGC ON, Smart IR LED range 30 mtr, Ture WRD, H.265/H.264 support, 2D/3D Noise reduction, IP66, Alarm1/1, Audio1/1, ROI, Defog, HLC, Corridor mode, DIS, SD card slot, BNC output FCC, CE, EN/UL certified, ONVIF profile S

98

-

-

... More
Supply, installation, testing and commissioning of Speed dome Camera with2 MP Sony 1/1.9" Starlight Image, H.265, H.264, MJPEG, 36x Optical Zoom, 32x Digital Zoom, f=5.8(Wide) - 210(Tele)mm, Min Illumination Color : 0.2 lux, B/W : 0.05 lux , Shutter speed- 1/30(25) sec ~ 1/300,000 sec, HLC/WDR/BLC/Defog, Pan : 360º endless, Tilt : 90º,Alarm in 7, Alrm out 3, LED Outdoor WDR/TDN PTZ IP camera , DC12V / AC24V; PoE++, 2 way Audio, minimum 254 preset, IP66, Auto scan support CE, FCC, EN/UL, Onvif Profile S

6

-

-

... More
Supply, installation, testing and commissioning of NVR with Operating System - Embedded LINUX, 16Ch, Video Compression - H.264, Audio - G.711/ Bi-directiona, Output Resolution - 1920x1080, Prerecord: 1~15 sec / Post-record: 5~180 sec, Ethernet Port - 1 (WAN) - 10/100/1000Mbps, Ethernet TX Speed - 64Mbps, HDD - 5 X 6TB (max) = 30TB, Internal RAID - RAID 5, 12VDC, Adaptor, 6.67A, 100~200VAC, 50-60Hz, 32ºF~104ºF (0ºC ~ 40ºC) CE, FCC, UL listed

13

-

-

... More
Supply, installation, testing and commissioning of VMS with170 Ip camera also support both 32 or 64-bit OS support,Supported codecs: H.264, MPEG4, MJPEG, JPEG, MxPEG,Advanced Failover,Video Analysis with Data Mining Filters, ONVIF, PSIA and RTSP Support,Digital Watermarking,two way audio,4K support,Unlimited client support,is an event-driven VMS that delivers complete IP, surveillance network management and scalability, Real-time geolocation / map / mobile-tracking, Access control integration, Video wall for enterprise command center (optional), Powerful FR, LPR & VCA modules

1

-

-

... More
Supply, installation, testing and commissioning of Intel Xeon Silver 4114 2.2G, 10C/2OT, 9.6GT/s, 14M Cache, Turbo, HT (85W) DDR4-2400, RAM - 16GB 2666MT/s RDIMMs, Windows Server 2016 (64 Bit) on dedicated mirrored solid-state drive, Broadcom 5720 Quad Port 1GB network daughter card, 2U Chassis with up to 8 x 3.5“ SAS/SATA Hard Drives, Dual, Hot-plug, redundant power supply (1+1), 750W, 2 x 120mm front fans, 2x 80mm top fans,

1

-

-

... More
6TB HDD, Interface Access Speed (Gb/s) – 6GB/S, Max. Sustained Transfer Rate OD (MB/s) - 190 MB/s, Workload Rate Limit (WRL) - 180TB, Mean Time Between Failures (MTBF, hours) – 1.0M, Load/Unload Cycles - 300,000,

80

-

-

... More
Supply, Installaiton, Testing & commissioning of Layer 2, 8 port POE+ Switch 8 port GigE with PoE, 2 x 1G SFP, LAN Litewith all accessories as per specs.

7

-

-

... More
Supply, installation, testing and commissioning of Layer 2, POE+ switch 24 port GE with PoE, 4 x 1G SFP, LAN Base all accessories as per specs

8

-

-

... More
Supply, installation, testing and commissioning of Outdoor Industrial Layer 2, 8 port POE+ Switch 8 port GigE with PoE, 2 x 1G SFP, LAN Litewith all accessories as per specs.

8

-

-

... More
Supply, installation, testing and commissioning of Layer 3, 24 port Fiber Core Switch equivalent to 24 Port GE SFP IP Services with stacking cable & stacking module as per specs.

2

-

-

... More
Supply, installation, testing and commissioning of 1000BASE-LX/LH SFP transceiver module, MMF/SMF, 1310nm, DOM.

85

-

-

... More
Supply, installation, testing and commissioning of 1000BASE 1000Mbps Single Mode Rugged SFP.

16

-

-

... More
Supply, installation, testing and commissioning of 1000BASE-T SFP transceiver module for Category 5 copper wire.

24

-

-

... More
Supply, installation, testing and commissioning of Diagonal screen size (inch) 48 inch, Optimum resolution - 1920 x 1080 @60Hz, Brightness - 350 NITS, Dynamic contrast ratio - 500,000:1, Aspect ratio - 16:9, Viewing angle (horizontal and Vertical) - 178 degree

8

-

-

... More
Supply, installation, testing and commissioning of Diagonal screen size (inch) 55 inch, Optimum resolution - 1920 x 1080 @ 60Hz, Brightness - 350 NITS, Dynamic contrast ratio - 500,000:1, Aspect ratio - 16:9, Viewing angle (horizontal and Vertical) - 178 degree

10

-

-

... More
Supply, installation, testing and commissioning of Client worlstations for monitoring Intel i5 or higher, Intel chipset Motherboard, 4 GB RAM, 500 GB HDD, High end Dual Graphic Cards, HDMI Ports, USB 2 ports, Converter for USB to RS 232/RS485, with Keyboard, Mouse.

4

-

-

... More
Supply, installation, testing and commissioning of 12U Rack Frame, 600 mm(W) X 500 mm (D) X 498 mm (H), Pre-configured 19" Wall-Mount Enclosure for networks, Passive ventilation with vent slots, Wall-Mount Enclosure with front glass door, Key lock arrangement, Top and bottom with vents, 4 rubber grommets for cable entry, Ø 50 mm, Mounting provision for two fans (fans optional),

35

-

-

... More
Supply, installation, testing and commissioning of 12U Rack Frame, 600 mm(W) x 500 mm (D) x 498 mm (H), Pre-configured 19" Wall-Mount Enclosure for networks, Passive ventilation with vent slots, Wall-Mount Enclosure with front glass door, Key lock arrangement, Top and bottom with vents, 4 rubber grommets for cable entry, Ø 50 mm, Mounting provision for two fans (fans optional),

8

-

-

... More
Supply, installation, testing and commissioning of 42U Rack Frame, Width: 800 mm, Height: 1200 mm, Depth: 1000 mm, Load capacity:10000 N, Sheet steel, Doors, roof and side panels: Dipcoat-primed and powder-coated, Glazed door: Single-pane safety glass, 3 mm

1

-

-

... More
Supply, installation, testing and commissioning of UTP 4 pair 23 AWG CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair CAT6 Unshielded, Twisted Pair (U/UTP) Cable 305 mtr per Box. Blue/Orange/White/Green in colour conforming to the following standards like ANSI EIA/TIA 568 C.2, EN50173, IEC 11801 3rd ED, frequency tested upto 700Mhz with Third Party Certificate etc. Cable Dia 6.1 ± 0.3, Cross-member (+) fluted Spine/isolator for uniform separation for all pairs.

11500

-

-

... More
Supply and fixing of 6 core indoor/outdoor Armoured OS1/OS2 Singlemode Optical Fiber of size 9/125μm. Central loose tube with jelly construction with embeded strength member(sttel wire) with antibuckling properties. Permanent tensile strength minimum 500N, Maximum installation load 1500N, Impact resistance 20Nm, Crush resistance 2000N/100mm,complying to for IEC 60793-2-50 class B.1.3,EN 60793-2-50: class B1.3, ITU Recommendation G.652.Dand confirming to EN 50 173-1:2007, cat. OS2; also OS1, ISO/IEC 11801:2002, cat.OS1, ISO/IEC 24702:2006, cat. OS2, IEEE 802.3-2002 incl. amendment 802.3ae - 2002. through existing GI/HDPE/ Hume pipe or on cable trays inside the cable duct including all necessary fixing accessories e.g. cable ties, hardware etc.

12500

-

-

... More
Supply, installation, testing and commissioning of 12 port LIU of 19" slide-in modular optic drawers with galvanised steel accommodates up to 4 fibre optic units, 4 cables, accommodates up to 24 ST and SC connectors and 48 LC connectors. Should meet EN50173 and ISO/IEC 11801 operating specifications.

25

-

-

... More
Supply, installation, testing and commissioning of 10 GB - 9/125μm OS1/OS2 SC LSZH Pigtails SM 9/125mm confirming to ITU-G651 and TIA/EIA 492AAAA standards.

300

-

-

... More
Supply, installation, testing and commissioning of 6 port LCS2 Adapter plate, loaded with 6 nos. of SC unit for 6 Single mode fibers of size 9/125 μm .Adapters to be compatible to fit in 19" U/UTP 24 port modular patch panel or 24 port LIU.

50

-

-

... More
Supply, installation, testing and commissioning of fibre stackable splicetray - 24 fibre capacity.

25

-

-

... More
Supply, installation, testing and commissioning of Blanking plate for 12 port LIU and Modular Patch Panel (Size 6 X RJ45 Blanking plate). For 19" Panel - Black in colour).

50

-

-

... More
Supply, installation, testing and commissioning of 24 port LIU of 19" slide-in modular optic drawers with galvanised steel accommodates up to 4 fibre optic units, 4 cables, accommodates up to 24 ST and SC connectors and 48 LC connectors. Should meet EN50173 and ISO/IEC 11801 operating specifications.

1

-

-

... More
Supply, installation, testing and commissioning of 10 GB - 9/125μm OS1/OS2 SC LSZH Pigtails SM 9/125mm confirming to ITU-G651 and TIA/EIA 492AAAA standards .

24

-

-

... More
Supply, installation, testing and commissioning of 6 port LCS2 Adapter plate, loaded with 6 nos. of SC unit for 6 Single mode fibers of size 9/125 μm .Adapters to be compatible to fit in 19" U/UTP 24 port modular patch panel or 24 port LIU.

4

-

-

... More
Supply, installation, testing and commissioning of fibre stackable splicetray - 24 fibre capacity.

1

-

-

... More
Supply, installation, testing and commissioning of 24 port Cat 6 19" Modular Toolless Patch Panel (loaded) enable all possible combinations of the various types of cable (UTP, FTP, SFTP) mounted on the same panel by using various toolless connector blocks/modules. Have a metal structure enabling them to be durably fixed to the uprights of the 19” chassis and assuring automatic grounding between toolless RJ-45 connectors, the panel, and the 19” uprights of the enclosure. Include rear cable support with plastic cable guides to hold cable without need for cable ties. Include quick mounting system to mount the panel into the 19” rails without use of cage-nuts. These may be used to secure the connections of wifi access points, IP cameras, servers, or other critical devices. Front Removal IO's option for maintenance and trouble shooting with 6 Different Colours Labels for Labelling & Identification of Individual Ports. Tested and guaranteed under dual circuit IEEE PoE++ up to 90W for up to 2500 on-load connections / disconnections.

25

-

-

... More
Supply, installation, testing and commissioning of CAT6 UTP 24 AWG Patch Cord - 2 mtr with cross separator Factory crimped multistranded copper patch cord with tensile strength of 50N. Conforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, UL VW-1 with tensile strength 50N, number of insertion is 750.

169

-

-

... More
Supply, installation, testing and commissioning of CAT6 UTP patch cord, 3 mtr, AWG 23 stranded cable, contact resistance - = 20 mOhm, flame retardance - UL 94 V-0 ANSI/TIA-568-C.2, ISO/IEC 11801 class E

20

-

-

... More
Supply, installation, testing and commissioning of 10 GB - 9/125μm OS1/OS2 SC-LC Duplex Fiber Patch Cord - 3 mtrs. Conform to IEC 61754-20,61300-2-1,61300-2-2,61300-2-4,61300-2-5 ANSI-TIA, and Telecordia performances requirements.

70

-

-

... More
Supply, installation, testing and commissioning of Single port Face Plate : Flush & surface mount. Polycarbonate Hi-Grade Plastic FR Grade with ABS underplate & CRCA metal fram & UV Resistant 850 degree C/ Glow Wire Test. The face plate should be compatible for Cat5e, Cat6 range of RJ45 and different types of AV connectors.The face plate Size should be of minimum 86x86mm with back box

200

-

-

... More
Supply and Laying of copper Armoured 2 x 1.5 Armoured twisted sheather power cable

5000

-

-

... More
Supplying and fixing of following sizes of heavy duty minimum 2.0mm thick FRLS PVC conduit as per IS:9537 Part-3 latest as on date along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm

5000

-

-

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm

7500

-

-

... More
Supplying & erection of 6 m MS pole with 35-55 micron Anti rust coating & PU (PolyUrethane) Painted, the pole coating includes red oxide, plaster and PU synthetic paint coatings in 2 layers. The pole shall be-3.0mm thick with 60 mm outer dia with 4 nos of GI. founadation nut & bolt (25mm dia & 250mm long) with a base plate of 300mm X 300mm, Base Plate thickness- 15 mm, 2Nos Template complete as required. (Note: The foundation for poles shall be provided by civil contractor) For PTZ camera

6

-

-

... More
Supplying & erection of 6 m MS pole with 35-55 micron Anti rust coating & PU (PolyUrethane) Painted, the pole coating includes red oxide, plaster and PU synthetic paint coatings in 2 layers. The pole shall be-3.0mm thick with 60 mm outer dia with 4 nos of GI. founadation nut & bolt (25mm dia & 250mm long) with a base plate of 300mm X 300mm, Base Plate thickness- 15 mm, 2Nos Template complete as required. (Note: The foundation for poles shall be provided by civil contractor) For outdoor camera

11

-

-

... More
SECURITY SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of Motorized Vehicle Barrier. The barrier shall use a blockable DC High Torque Drive in combination with standard interfaced Controller. It shall offer LCD Display & Graphic User Interface for easy control setting, integrated Two channel Loop Detector, Vario Boom of 4 Meters length with 4.0 Sec Opening/ Closing time and Maximum Power Consumption of less than 100 Watts, with 100% duty cycle high performance Drive unit providing best operation even under severe weather conditions (heavy winds etc) having 10 million opening and closing movements or a minimum of 10 years in a vehicle gate application, integrated resolver for precise positioning feedback, high output torque for fast acceleration and deceleration, wide voltage range 85-264 V AC 50Hz, IP 54 rated powder coated All Aluminium housing with base frame made of Stainless Steel for high protection against corrosion for Outdoor application.

4

-

-

... More
Supply, installation, testing and commissioning of Motorized Vehicle Barrier. The barrier shall use a blockable DC High Torque Drive in combination with standard interfaced Controller. It shall offer LCD Display & Graphic User Interface for easy control setting, integrated Two channel Loop Detector, Vario Boom of 6 Meters length with 4.0 Sec Opening/ Closing time and Maximum Power Consumption of less than 100 Watts, with 100% duty cycle high performance Drive unit providing best operation even under severe weather conditions (heavy winds etc) having 10 million opening and closing movements or a minimum of 10 years in a vehicle gate application, integrated resolver for precise positioning feedback, high output torque for fast acceleration and deceleration, wide voltage range 85-264 V AC 50Hz, IP 54 rated powder coated All Aluminium housing with base frame made of Stainless Steel for high protection against corrosion for Outdoor application.

2

-

-

... More
Supply, installation, testing and commissioning of Tyre spikes of 3 meter length as per specs along with all accessories as required.

4

-

-

... More
Supply, installation, testing and commissioning of Tyre spikes of 4.5 meter length as per specs along with all accessories as required.

2

-

-

... More
SITC of 3 D - complete UVSS unit, generally as per the technical specification and compliance statement furnished, comprising Color Area Scan camera, Driver photo module, Automated License plate reader module, all related Software.

3

-

-

... More
PART-O : HVAC WORKS

-

-

-

... More
Supply, installation, testing and commissioning of Screw type air-cooled chilling unit of 100 TR actual capacity at the parameters indicated below. complete with Semi-hermetic/hermetic type Helical Rotary Screw dual compressors, dual circuit, Shell & tube type, stepless control, direct expansion/flooded evaporator, elctronic expansion valve, motor, insulated chiller, air cooled condenser, Spring vibration isolators, integrated refrigerant piping, fittings & valves and wiring, first charge of factory filled refrigerant (CFC free R-134 a)and lubricant, microprocessor based control panel, accessories as required and called for, automatic and safety controls and all mounted on a steel frame as per specifications. Motor shall be suitable for 415 ± 10% V, 50Hz, 3ph AC supply as per specification and drawings. The quoted rate shall also include foundation alongwith MS girder section to install on terrace, with soft starter, cables, cable tray, dmbs,Soft Starter with Modulation to the panels etc. Motor along with Spring Type Isolators shall be suitable for 415 ± 10% V, 50Hz, 3ph AC supply as per specification. Chillers should be Eurovent/AHRI certified. Country of origine France/ Italy / US .Max Permissible IKW at above Conditions shall not Exceed 1.4 IKW/ TR including condensor fans power.Condesnsor Constracution shall be CU-AL. Uni Metal Microchannel Heat Exchanger not Acceptable. It should be complete as per manufacturer's Specifications & as directed by Engineer-in-charge. Necessary civil work required for the above equipment shall be included in this item quoted price.The chiller shall be Witness tested at Manufacturers Premises on 2 points-(100% & 50 %) on AHRI Conditions as per the AHRI Standards. Ambient Condition: 43.3 Degree c Chiller Chilled water inlet : 54o F

-

-

-

... More
Chilled water outlet : 44o F Fouling Factor : 0.0001 (FPS) (The cost of BMS compatible card shall be included in each chiller) Chilling machine COP at shall be min 3.1 & and all performance requirements are at ARI 550/590 -1998 Test conditions. 100TR (2W+2S)

4

-

-

... More
PUMPING SYSTEM Note: Head loss calculation shall be submitted by the agency as per Site Condition.

-

-

-

... More
Chilled Water Pumps Primary constant chilled water pumps Supply, installation, testing and commissioning of Vertical in-line split coupled pump with dmbs, PN16 rating and SS 416 shaft fitted with outside type balanced mechanical seal for chilled water primary pump set each capable of delivering the specified flow rate comprising the following and complete as per specifications. i) 2 Nos. (1W+1S) Vertical Inline Split Coupled pump ii) Motor shall be suitable HP TEFC induction motor with Efficiency IE3, class `F' insulation operating on 415 + 10% volts, 3 phase, 50 cycles AC supply. iii) Flow rate 240 USGPM and 15 M head (1W+1S)

2

-

-

... More
Secondary Variable chilled water pumps Supply, installation, testing and commissioning of Vertical in-line split coupled pump with dmbs, PN16 rating and SS 416 shaft fitted with outside type balanced mechanical seal for chilled water secondary variable pump set each capable of delivering the specified flow rate comprising the following and complete as per specifications.nirvay i) 2 Nos. (1W+1S) Vertical Inline Split Coupled pump ii) Motor shall be suitable HP TEFC induction motor with Efficiency IE3 class `F' insulation operating on 415 + 10% volts, 3 phase, 50 cycles AC supply. iii) VFD shal be with IP-55 protection and shall be integrated with motor for sensorless control iv) Flow rate 240 USGPM and 30 M head (1W+1S) If DPTs are used to control the VFD then the DPT cost and wiring cost between DPT to PLC / VFD shall be included in the prices

2

-

-

... More
Chilled Water Pumps Primary constant chilled water pumps Supply, installation, testing and commissioning of Vertical in-line split coupled pump with dmbs, PN16 rating and SS 416 shaft fitted with outside type balanced mechanical seal for chilled water primary pump set each capable of delivering the specified flow rate comprising the following and complete as per specifications. i) 2 Nos. (1W+1S) Vertical Inline Split Coupled pump ii) Motor shall be suitable HP TEFC induction motor with Efficiency IE3, class `F' insulation operating on 415 + 10% volts, 3 phase, 50 cycles AC supply. iii) Flow rate 240 USGPM and 15 M head (1W+1S)

2

-

-

... More
Secondary Variable chilled water pumps Supply, installation, testing and commissioning of Vertical in-line split coupled pump with dmbs, PN16 rating and SS 416 shaft fitted with outside type balanced mechanical seal for chilled water secondary variable pump set each capable of delivering the specified flow rate comprising the following and complete as per specifications.nirvay i) 2 Nos. (1W+1S) Vertical Inline Split Coupled pump ii) Motor shall be suitable HP TEFC induction motor with Efficiency IE3 class `F' insulation operating on 415 + 10% volts, 3 phase, 50 cycles AC supply. iii) VFD shal be with IP-55 protection and shall be integrated with motor for sensorless control iv) Flow rate 240 USGPM and 30 M head (1W+1S) If DPTs are used to control the VFD then the DPT cost and wiring cost between DPT to PLC / VFD shall be included in the prices

2

-

-

... More
NOTE:- Actual Pump head may vary at site conditions please submit Head Calculation sheet, Before selecting pumps, Applicable to all pumps.

-

-

-

... More
HOT WATER GENERATOR WITH CANOPY SUITABLE FOR OUTSIDE CONDITION Supply, installation, testing and commissioning of Electric Hot Water Generator of vertical construction equipped with sufficient number of flanges and electric immersion heaters. The pressure vessel shall be constructed as per ASME standards and insulated dmbs, on all sides with 50 mm thick fiberglass with 0.60mm Aluminum cladding as per specifications. The hot water generator shall be equipped with all automatic and safety controls such as high temperature water thermal cutout, Low water level cut-off, PLC, HMI other controls as per tender specifications. The hot water generator shall be control by PLC based Step controller and HMI screen and BMS compatible having Ethernet/RS485 Port. All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The hot water generator shall be suitable for 415 volts, 50 Hz, 3 phase power supply.The entire hot water generator shall be factory assembled and tested. 50 kw for Winter heating only (2W+2S) Note: a) Water ‘IN’ temperature : 45 deg C. b) Water ‘OUT’ temperature : 50 deg C

4

-

-

... More
Hot Water Pumps Supply, installation, testing and commissioning of monoblock pump for hot water pump set each capable of delivering the specified flow rate comprising the following and complete as per specifications. i) 2 Nos. (1W+1S) vertical split casing ii) Motor shall be suitable HP TEFC induction motor with Efficiency IE3, class `F' insulation operating on 415 + 10% volts, 3 phase, 50 cycles AC supply. iii) Flow rate 30 USGPM and 30 METER head (2W+2S)

4

-

-

... More
MICROBUBBLE AIR & DIRT SEPRATOR Supply, installation, testing & commissioning of Micro bubble Air & Dirt Separator capability,automatic air purging arrangement etc.The shell shall be constructed of mild steel with coalescence. It shall work on the principle of coalescence. The water velocity the shall not Exceed 1.5m/sec.The M.S shall to be fabricated or other similar standard.The inlet and outlet connections shall be flanged. It shall be provided with a high capacity auto air vent at the to and a drain valve at the bottom.Matching flanges, high tensile bolts & nuts and gasket shall be also provided by dmbs, the manufacturer. it shall be duly insulated 32mm thick class O Nitrile rubber insulation as per specifications complete as per specifications.The design parameters for the air separator of efficiency 96-98% should be as follows with Safety working pressure:3.5 bar (32mm thick insulation) Line Size: 100 mm diameter

2

-

-

... More
CUBICAL PANEL BOARD FOR HIGH SIDE EQUIPMENTS For 2 x100 TR Air Cooled Screw M/C (1W +1S ) For 2 x 7.5 HP chilled water Primary Pumps(1W+1S ) For 2 x 15 HP chilled water Secondry Pumps(1W+1S ) For 2 x 50 kW Hot Water Generator (1W+1S ) For 2 x 7.5 HP Hot water Pumps(1W+1S ) Supply, Installation, Testing & Commissioning of Cubical type sectinalised floor standing switch Board of 31 MVA fault capacity at 415 V complete made out 2.0 mm thick CRCA Sheet With 3.5 strip 1 x 450A capacity Aluminium Bus- Bar Electrolytic grade cable alley switchgears of following capacity & as per specifications. PANEL ROOM FOR AUDITORIUM BLOCK AC PLANT ROOM INCOMER Incomers –1 No. x 450 Amps TPN MCCB 50 kA for O/C, S/C& E/F proctection, reverse power relay- trip & RS485 Port, cable connection on one side and Busbar connection on the other side. INDICATING PANEL Provide 1 No. phase indicating lamps LED each backed up with fuse & switch. Provide 800/5a CT CI-1,15VA operated Digital Ammeter for all in-comers and outgoings including C/T's. Provide 0-500 Volts range Digital Volt Meter with selector switch for all incomers Two numbers indicating lamps LED on each incoming and outgoing feeder for indicating the status of feeder. One number indicating lamp LED on each incoming and outgoing feeder for indicating that the feeder has tripped due to fault condition.

-

-

-

... More
1 No. Power factor meter 1 No. Digital type energy meter. Break Control Switch (T-N-C) Control Fuse+Base BUSBARS Sections of 1Nos x 500 Amps TPN bus bar chamber of suitable lengths with Aluminium bus bars. All bus bars and interconnections shall be of suitable size Al strips. Current density of Al shall not be more than 1.0 Amps/ sq.mm cross sectional area of Bus Bar SET 2 NOS Incomer and bus coupler shall be mechanically & electrically interlocked to avoid paralleling of the two supplies. OUTGOING For 2 x100 TR Air Cooled Screw M/C (1W +1S ) TPN MCCB of suitable rating with overload, short circuit protection with ammeter with three CT & selector switch, on /off /trip indication light with control MCB. MCCB Shall be 25 KA (ICU=ICS) SET - 02 For 2 x 7.5 HP chilled water Primary Pumps(1W+1S ) TPN MCCB of suitable rating with 7.5 HP Dol starter, overload relay inbuilt single phase prevention, start/stop push buttons, dgital ammeter with three CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 25 KA (ICU=ICS) SET - 02 For 2 x 15 HP chilled water Secondry Pumps(1W+1S ) TPN MCCB of suitable rating with 15 HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, dgital ammeter with three CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 25 KA (ICU=ICS) SET - 02

-

-

-

... More
For 2 x 50 kW Hot Water Generator (1W+1S ) TPN MCCB of suitable rating overload relay inbuilt single phase prevention, start/stop push buttons, digital ammeter (0- 400A) with three CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 25 KA (ICU=ICS) SET - 02 For 2 x 15 HP Hot Water Pumps(1W+1S ) TPN MCCB of suitable rating with 15 HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, dgital ammeter with three CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 25 KA (ICU=ICS) SET - 02 5 nos. Vacant Space for outgoing feeders sufficient to accommodate MCCB and Starter with 'hands", "off", automatic mode selection switch of each type.

1

-

-

... More
PANEL ROOM FOR SPORT COMPLEX AC PLANT ROOM INCOMER Incomers –1 No. x 450 Amps TPN MCCB 50 kA for O/C, S/C& E/F proctection, reverse power relay- trip & RS485 Port, cable connection on one side and Busbar connection on the other side. INDICATING PANEL Provide 1 No. phase indicating lamps LED each backed up with fuse and switch. Provide 800/5a CT CI-1,15VA operated Digital Ammeter for all in-comers and outgoings including C/T's. Provide 0-500 Volts range Digital Volt Meter with selector switch for all incomers Two numbers indicating lamps LED on each incoming and outgoing feeder for indicating the status of feeder. One number indicating lamp LED on each incoming and outgoing feeder for indicating that the feeder has tripped due to fault condition. 1 No. Power factor meter 1 No. Digital type energy meter. Break Control Switch (T-N-C) Control Fuse+Base BUSBARS Sections of 1 No. x 500 Amps TPN bus bar chamber of suitable lengths with Aluminium bus bars. All bus bars and interconnections shall be of suitable size Al strips. Current density of Al shall not be more than 1.0 Amps/ sq.mm cross sectional area of Bus Bar SET 2 Nos. Incomer and bus coupler shall be mechanically & electrically interlocked to avoid paralleling of the two supplies.

-

-

-

... More
OUTGOING For 2 x100 TR Air Cooled Screw M/C (1W +1S ) TPN MCCB of suitable rating with overload, short circuit protection with ammeter with three CT & selector switch, on /off /trip indication light with control MCB. MCCB Shall be 25 KA (ICU=ICS) SET - 02 For 2 x 7.5 HP chilled water Primary Pumps(1W+1S ) TPN MCCB of suitable rating with 7.5 HP Dol starter, overload relay inbuilt single phase prevention, start/stop push buttons, dgital ammeter with three CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 25 KA (ICU=ICS) SET - 02 For 2 x 15 HP chilled water Secondry Pumps(1W+1S ) TPN MCCB of suitable rating with 15 HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, dgital ammeter with three CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 25 KA (ICU=ICS) SET - 02 For 2 x 50 kW Hot Water Generator (1W+1S ) TPN MCCB of suitable rating overload relay inbuilt single phase prevention, start/stop push buttons, digital ammeter (0- 400A) with three CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 25 KA (ICU=ICS) SET - 02 For 2 x 15 HP Hot Water Pumps(1W+1S ) TPN MCCB of suitable rating with 15 HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, dgital ammeter with three CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 25 KA (ICU=ICS) SET - 02 5 nos. Vacant Space for outgoing feeders sufficient to accommodate MCCB and Starter with 'hands", "off", automatic mode selection switch of each type.

1

-

-

... More
POWER & CONTROL CABLING AND EARTHING Supplying, laying, effecting proper connections, testing & commissioning of the following sizes of 1.1 KV -Cross Linked Poly Ethelene armoured aluminium conductor cables conforming to relevant latest amended Indian Standards laid over MS supports & Cable Trays including clamping the cables to supports in an approved manner as required complete with all accessories as per IS 7098(Part 1) 1988 as per approved GTP. For Screw Water- Cooled Chilling M/C

-

-

-

... More
(a) 4.0 C x 185 Sq. mm

100

-

-

... More
For Hot Water Generator

-

-

-

... More
(a) 4.0 C x 95 Sq. mm

100

-

-

... More
For Pump

-

-

-

... More
(a) 3C x 10 Sq. mm

320

-

-

... More
(b) 3C x 16 Sq. mm

100

-

-

... More
Earthing Strip / Wires. Supply & laying of 8 SWG. GI wire. or in recess for loop earthing as required.

150

-

-

... More
Supply & laying 25x5mm GI strip at 0.5mt below ground as strip earth electrde including connection/terminatng with GI nut,bolt, spring, washer etc. as required.) jointing shall be done by overlapping & with 2 sets of brass nuts bolt & spring washer spaced at 50mm).

400

-

-

... More
Supply, testing, commissioning of earth pits with 40mm dia 3 mtr long GI pipe complete with Salt and Charcol, Masonary Chamber water pipe etc. complete

4

-

-

... More
VARIABLE REFRIGERANT FLOW AIR-CONDITIONING SYSTEM Supply, installation, testing and commissioning of Variable Refrigerant Flow modular type airconditioning system Invertor Controlled with stepless modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling dmbs, etc.as per detail given in specifications and having following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A. Supply, installation, testing and commissioning of Outdoor Unit with blue fin coating Supply, installation, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll compressors with both inverter speed type compressors special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below. Minimum Part Load at which machine should work should be 20%

-

-

-

... More
JCO GYM AREA

-

-

-

... More
18 HP HEAT PUMP TYPE ( HEATING AND COOLING BOTH )

3

-

-

... More
Supply Instalaltion, testing and commissioning of Y-joints.

3

-

-

... More
Supply Instalaltion, testing and commissioning of self diagnostic type remote controllers. Corded Type

3

-

-

... More
Supply Instalaltion, testing and commissioning of Main Intelligent central controller system Touch Screen suitable for above indoor units to operate, monitor, on/off, temperature setting etc.

1

-

-

... More
FLOOR MOUNTED CHILLED WATER AIR HANDLING UNITS BACKWARD CURVED Supply, installation, testing and commissioning of factory built Eurovent Complient Air handling units in Double skin type (Casing shall be of Non-Skeleton construction) with 40 mm thick panels with thermal break construction consisting of G.I casing of thickness 0.6 mm outside layer and 0.6 mm inside layer with 275 GSM zinc coating and polyurethene foam (PUF) insulation having density of 42 kg/m3, complete with Backward curved aerofoil blade Plug type direct driven fan alongwith VFD suitable for static pressure as dmbs, detailed below, chilled water cooling coil with aluminium finned copper tubes. Filter section having 50 mm thick pre filters, TEFC motor suitable for 415 +10% volts, 50 Hz, 3 phase AC supply, drain connections with stainless steel drain pan and necessary vibration isolation arrangement to avoid any vibration etc. complete as per specifications and drawings. i) The face velocity across cooling coil shall be limited to 152 MPM maxm. ii) Fan Oulet Velocity Not to Exceed 8.5 m/s iii) 4 RD Heating / 2RD Cooling Coil(CC) iv) The complete AHU shall confirm to above & standard specification. v) Pre-filter section with Pre filter(10 Micron & 90 % Efficiency) in All following AHUS The complete AHU shall confirm to above & standard specification.

-

-

-

... More
AUDITORIUM BLOCK

-

-

-

... More
FM AHU 1x9500 CFM/22 TR/70 MM Static/6RD

1

-

-

... More
FM AHU 1x12000 CFM/25.5TR/70 MM Static/6RD

2

-

-

... More
FM AHU 1x13500 CFM/27 TR/70 MM Static/6RD

1

-

-

... More
CEILING SUSEPENDED CHILLED WATER AIR HANDLING UNITS( FORWARD CURVED ) Supply, installation, testing and commissioning of factory builtEurovent Complient Air handling units in Double skin type (Casing shall be of Non-Skeleton construction) with 40 mm thick panels with thermal break construction consisting of G.I casing of thickness 0.6 mm outside layer and 0.6 mm inside layer with 275 GSM zinc coating and polyurethene foam (PUF) insulation having density of 42 kg/m3, complete with forward curved aerofoil blade Plug type direct driven fan alongwith VFD suitable for static pressure as dmbs, detailed below, chilled water cooling coil with aluminium finned copper tubes. Filter section having 50 mm thick pre filters, TEFC motor suitable for 415 +10% volts,50 Hz, 3 phase AC supply, drain connections with stainless steel drain pan and necessary vibration isolation arrangement to avoid any vibration etc. complete as per specifications and drawings. i) The face velocity across cooling coil shall be limited to 152 MPM maxm. ii) Fan Oulet Velocity Not to Exceed 8.5 m/s iii) 4 RD Heating / 2RD Cooling Coil(CC) iv) The complete AHU shall confirm to above & standard specification. v) Pre-filter section with Pre filter(10 Micron & 90% Efficiency) in All following AHUS The complete AHU shall confirm to above & standard specification.

-

-

-

... More
AUDITORIUM BLOCK

-

-

-

... More
(a) CS AHU 1x1400 CFM/2TR/4RD/40 MM Static

1

-

-

... More
(b) CS AHU 1x2600 CFM /5TR /40 MM static/4RD(1w+1s)

2

-

-

... More
SPORTS COMPLEX

-

-

-

... More
(a) CS-AHU 1x3000 CFM/10TR/6RD/50 MM Static

1

-

-

... More
(b) CS AHU 1x4000 CFM/20TR/6RD/50 MM Static

1

-

-

... More
(c) CS-AHU 1x4500 CFM/13.8TR/6RD/50 MM Static

2

-

-

... More
(d) CS AHU 1x5000 CFM/15TR/6RD/50 MM Static

1

-

-

... More
(e) CS-AHU 1x6000 CFM/21TR/6RD/50 MM Static

1

-

-

... More
FAN COIL UNITS Supply, installation, testing and commissioning of the following equipment as per tender drawings, and specifications. fcu complete with filter box complete with synthetic fiber filters, cooling coil, fans, 3-speed motors, drain pipe connection with drain pump complete. Copper flexible connection complete with set of ball valves with strainer & ball valves without strainer. Electrical and control cabling for proper connection from the 15 amps outlet to connector box, valve etc. as well as connection of thermostat. Controls for units comprising of thermostat, Two way motorised control valve, control wiring. Hydronic units of minimum capacity in BTU/HR & CFM as follows :

-

-

-

... More
(a) 18000Btu/Hr /3RD /600CFM

1

-

-

... More
(b) 24000Btu/Hr /3RD /800CFM

2

-

-

... More
CEILING SUSPENDED AIR HANDLING UNIT DX TYPE WITH FORWARD CURVE FANS Supply, installation, testing and commissioning of factory built Eurovent Complient Air handling units in Double skin type (Casing shall be of Non-Skeleton construction) with 40 mm thick panels with thermal break construction consisting of G.I casing of thickness 0.6 mm outside layer and 0.6 mm inside layer with 275 GSM zinc coating and polyurethene foam (PUF) insulation having density of 42 kg/m3, complete with forward curved aerofoil blade Plug type direct driven fan alongwith VFD suitable for static pressure as detailed below, chilled water cooling coil with aluminium finned copper tubes. dmbs, Filter section having 50 mm thick pre filters, TEFC motor suitable for 415 +10% volts, 50 Hz, 3 phase AC supply, drain connections with stainless steel drain pan and necessary vibration isolation arrangement to avoid any vibration etc. complete as per specifications and drawings. i) The face velocity across cooling coil shall be limited to 152 MPM maxm. ii) Pre-filter section with Pre filter (10 Micron & 90% Efficiency) in All following AHUS iii) Fan Oulet Velocity Not to Exceed 8.5 m/s Accessories for AHU kit Expansion Device & control box DX cooling coil, Expansion device, communication kit, canvass connection and remote control etc The complete AHU shall confirm to above & standard specification. JCO GYM CS AHU 1x4500 CFM/15TR/6RD/50 MM Static

3

-

-

... More
DUCT MOUNTED AIR PURIFICATION SYSTEM Supply, installation, testing and commissioning of duct mounted air purification system/ cell based on Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space dmbs,. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital.

-

-

-

... More
(a) PHI for 2000 CFM

10

-

-

... More
(b) PHI for 2500 CFM

25

-

-

... More
(c) PHI for 5000 CFM

15

-

-

... More
(d) PHI for 10000 CFM

18

-

-

... More
AUDITORIUM

-

-

-

... More
(a) PHI for 1400 CFM

1

-

-

... More
(b) PHI for 2600 CFM

2

-

-

... More
(c) PHI for 9500 CFM

1

-

-

... More
(d) PHI for 12000 CFM

2

-

-

... More
(e) PHI for 13500 CFM

1

-

-

... More
SPORT COMPLEX

-

-

-

... More
(a) PHI for 3000 CFM

1

-

-

... More
(b) PHI for 4000 CFM

1

-

-

... More
(c) PHI for 4500 CFM

2

-

-

... More
(d) PHI for 5000 CFM

1

-

-

... More
(e) PHI for 6000 CFM

1

-

-

... More
DX TYPE HI WALL UNIT (GREEN GAS) Supply, installation, testing & Commissioning of DX type split AC units with air cooled condenser mounted in outdoor unit complete with scroll/rotary compressor, condensor, wiring & accessories. Indoor units shall be wall mounted type complete with evaporator, fan, filter, drier, expansion devices & microprocessor control panel along with all accessories with refrigerant & oil charge, cordless remote controls. The unit shall be suitable for working, 50 cycle /second, 1 phase AC supply.The unit shall be designed to take care of veritcal head 4mt & horizontal length of 30 mt & necessary oil seprator shall be included, necessary supporting arrangement for both indoor & outdoor units ( Powder Coated /Epoxy painted MS stand for ODU units as per approved make shade by Architect) with necessary vibration isolation arrangement as per site condition etc. (without condensate drain pipe, electrical pipe, electrical power & control cabling between indoor & outdoor unit which shall be paid seprately ). The Color of the outdoor units to be finalized by the Architect as per building Architectural elevation. The coil in the outdoor units shall be provided with anti corrosive treatment . The contractor shall visit the site & check the pollutant level such as Sulphur content & harmful acid content in the atmosphere near site & accordingly anticorrosive paint treatment of coil to be provided. All Unit shall be Minimum 3 Star Rating Based The Outdoor unit Compressor must be provided with 5 Year Warranty Period. Active Carbon filter, Silver Ion Filter, Dust Filter Civil Work such as wall hole making, wall chisling, refilling of chiseling part with mortar etc as per site condition.

-

-

-

... More
Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU with flar nuts Removable Covers for all indoor & Outdoor units shall be supplied & put on the units after installation & commissioning. Incoming power supply shall be provided near each indoor units 1.5 TR Dx type Hi wall Unit

2

-

-

... More
DOUBLE SKINNED AIR WASHER UNITS Supply, installation, testing & commissioning of factory fabricated double skin Air-Washer comprising of DIDW GI fan, backward curved, complete with base frame, casing made out of 0.63mm galvanised sheet having flanged & bolted panels insulated with 48 MM THICK & 48KG /M3 PUF injected between outer skin and inner skin.(The inner skin shall be PVC / Fibreglass lined also), wet section & tank shall be made of stainless steel. The Air-washer shall be complete with fill of depth 200mm & face velocity across the fill shall be limited to152 MPM.The complete Air-washer shall be as specified in the specification of tender document & Schedule of Equipments section.The Air -washer shall have an efficiency of 90% & shall be complete with motor, dmbs, belt drive package, GI B Class interconnecting piping, valves, strainer NRV, aluminum viscous filters, water pumps (1 working +1 stand by) for each air washer etc. & of the following capacities including all type of civil work like cutting/holes/ chasing/cut out in brick wall etc. All air washer tank to be FRP lined.

-

-

-

... More
INDOOR STADIUM

-

-

-

... More
TABLE TENNIS 5500 CFM No Of Fan For Each Air-washer = 1 forward curve Static Pressure = 50MM Fan Speed = Not exceeding 1000 RPM Motor Rating = Not Exceed 3.7 KW Noise level = not exceed 70 db at 3 meter distance Monoblock Pump = 0.75 KW No. Of Pumps = 2 (1 No. Standby)

1

-

-

... More
SQUASH COURT-01 6500 CFM No Of Fan For Each Air-washer = 1 forward curve Static Pressure = 50MM Fan Speed = Not exceeding 1000 RPM Motor Rating = Not Exceed 3.7 KW Noise level = not exceed 70 db at 3 meter distance Monoblock Pump = 0.75 KW No. Of Pumps = 2 (1 No. Standby)

2

-

-

... More
ENTRANCE LOBBY 8500 CFM No Of Fan For Each Air-washer = 1 forward curve Static Pressure = 50MM Fan Speed = Not exceeding 1000 RPM Motor Rating = Not Exceed 5.5 KW Noise level = not exceed 70 db at 3 meter distance Monoblock Pump = 0.75 KW No. Of Pumps = 2 (1 No. Standby)

1

-

-

... More
ENTRANCE LOBBY 11000 CFM No Of Fan For Each Air-washer = 1 forward curve Static Pressure = 50MM Fan Speed = Not exceeding 1000 RPM Motor Rating = Not Exceed 5.5 KW Noise level = not exceed 70 db at 3 meter distance Monoblock Pump = 0.75 KW No. Of Pumps = 2 (1 No. Standby)

2

-

-

... More
SPORT COMPLEX

-

-

-

... More
KITCHEN AREA 7500 CFM No Of Fan For Each Air-washer = 1 forward curve Static Pressure = 50MM Fan Speed = Not exceeding 1000 RPM Motor Rating = Not Exceed 3.7 KW Noise level = not exceed 70 db at 3 meter distance Monoblock Pump = 0.75 KW No. Of Pumps = 2 (1 No. Standby)

1

-

-

... More
SHOPPING COMPLEX

-

-

-

... More
LOBBY WAITING LOUNGE AREA 2000 CFM No Of Fan For Each Air-washer = 1 forward curve Static Pressure = 50MM Fan Speed = Not exceeding 1000 RPM Motor Rating = Not Exceed 2.2 KW Noise level = not exceed 70 db at 3 meter distance Monoblock Pump = 0.75 KW No. Of Pumps = 2 (1 No. Standby)

1

-

-

... More
KITCHEN 2500 CFM No Of Fan For Each Air-washer = 1 forward curve Static Pressure = 50MM Fan Speed = Not exceeding 1000 RPM Motor Rating = Not Exceed 2.2 KW Noise level = not exceed 70 db at 3 meter distance Monoblock Pump = 0.75 KW No. Of Pumps = 2 (1 No. Standby)

1

-

-

... More
MULTIPURPOSE HALL AND DINNING AREA 5000 CFM No Of Fan For Each Air-washer = 1 forward curve Static Pressure = 50MM Fan Speed = Not exceeding 1000 RPM Motor Rating = Not Exceed 2.2 KW Noise level = not exceed 70 db at 3 meter distance Monoblock Pump = 0.75 KW No. Of Pumps = 2 (1 No. Standby)

2

-

-

... More
DIDW FAN FOR EXHUAST IN NORMAL MODE VENTILATION Supply, installation, testing and commissioning of ceiling mounted DIDW fans (AMCA Certified) with adjustable pitch blade & angle ,MS/GI casing, cast aluminium alloy impeller completewithTEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4 pole,three Phase, A.C supply class"F" insulation with support & Motor rated Value IP55, mountings and flexible connection dmbs,etc. & of following capacity. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc Note : - Outlet Velocity not to exced 14.0 MPS Exhaust air in case of normal mode ventilation system

-

-

-

... More
INDOOR STADIUM

-

-

-

... More
Air Qty. = 5500 CFM Static Pressure = 30 mm Wg Motor Pole = 4 Pole Motor = Not exceeding 1.5 Kw.

1

-

-

... More
Air Qty. = 6500 CFM Static Pressure = 30 mm Wg Motor Pole = 4 Pole Motor = Not exceeding 1.5 Kw.

2

-

-

... More
Air Qty. = 8500 CFM Static Pressure = 30 mm Wg Motor Pole = 4 Pole Motor = Not exceeding 1.5 Kw.

1

-

-

... More
Air Qty. = 11000 CFM Static Pressure = 30 mm Wg Motor Pole = 4 Pole Motor = Not exceeding 1.5 Kw.

2

-

-

... More
SHOPPING COMPLEX

-

-

-

... More
Air Qty. = 2000 CFM Static Pressure = 25 mm Wg Motor Pole = 4 Pole Motor = Not exceeding 1.5 Kw.

1

-

-

... More
Air Qty. = 5000 CFM Static Pressure = 25 mm Wg Motor Pole = 4 Pole Motor = Not exceeding 1.5 Kw.

2

-

-

... More
DRY SCRUBBER UNIT Supply, installation, testing and commissioning of Scrubber each comprising of electrostatic precipitation technology, dry type air cleaner to remove oil, DIDW Backward curves Fan with casing 25mm thick PUF insulation, dmbs, smoke and fumes from exhaust air, as per the Specifications. Electrostatic Precipitator Module of following specifications Electrostatic section shall be made of 16 gauge galvanised sheet, high bake epoxy powder coated, washable type aluminium mesh pre filters, Ionizing-Collecting cell(s) shall be of one-piece construction minimum 13.38” inches deep in direction of airflow. All support framing, end plates and ionizer ground electrodes shall be 0.090 inch thick aluminum. Both repelling and collector plates shall be 0.020 inch thick aluminum, 9.125 inch deep in direction of airflow and rigidly retained in place with tubular spacers and tie rods.Spacing between plates shall be no less than 0.175 inch. Ionizing electrodes shall be heavy duty tungsten wire rigidly supported both vertically and laterally. High voltage support insulators shall be of made of Teflon, including center hole, glazed to enhance dielectric strength and retard tracking. Insulators shall be mounted out of the airstream, to reduce contaminant buildup. All high voltage electrical connections within each tier of cells, shall be between cells and automatically made when cells are installed. Average efficiency of 90% for single pass base on ASHRAE test method at flow rates of 800 –1500CFM per module. Power supplies shall be 100% solid state CE Listed, Module of capacity above 3000 CFM shall be equipped with Pulse width modulating dmbs,(PWM)The system should be fitted with interlock switch for safety . The system should allow connection to a fan section .

-

-

-

... More
All units shoud have Arc Supression & Auto Restart, Performance Indicator Lights to indicate the status of the air cleaning system. Power Consumption should not be more that 50 watts per ESP cell. Operating Voltage : 220V, 50 Hz Ionizing Voltage : 12.5 to 13 KVDC Collector Cell Voltage : 6 to 6.5 KVDC Power Consumption : Not more than 50W per cell. Air Moving Capacities shall be as follows: Ionizing-Collecting cell(s) shall be of one-piece construction consisting of a series of repelling & collection plates. Both repelling and collector plates shall be aluminum alloy material, rigidly retained in place with tubular spacers and tie rods. Each plate shall be corrugated, perpendicular to airflow direction. i) Each cell shall weigh not more than 15 kg with at least 9 ionizing wires ii) Maximum number of collection plates up 55 numbers per ESP cell. iii) Minimum collection plate area per 1000 CMH of air flow thru ESP Cell Should not less than 1.8 sqmt iv) Not less than MERV 15 v) Exhaust air unit of following specifications

-

-

-

... More
factory fabricated double skin exhaust air unit comprising of 2No.DIDW GI fan & motor, Backward curved, complete with base frame,casing made out of 0.63mm galvanised sheet having flanged & bolted panels insulated with PUF injected between outer skin and inner skin. The exhaust air unit shall be complete with motor, belt drive package of the following capacities. The unit shall be integrated & connected with above for kitchen including all necessary accessories to complete the installation.

-

-

-

... More
SHOPPING COMPLEX 3500 CFM

1

-

-

... More
SPORT COMPLEX 9000 CFM

1

-

-

... More
PROPELLER FANS Supply, installation, testing & commissioning of wall mounted Propellar fans complete with bird screen, rain guard, metal clad MCB ,5m length copper cable, earthing wire all compete as required of following capacities & as per shop drawing mentioned. Including all type of civil work like cutting/holes/ chasing/cut out in brick wall etc

-

-

-

... More
(a) 300 mm dia

4

-

-

... More
(b) 225 mm dia

8

-

-

... More
INLINE FAN WITH SPEED REGULATOR Supply, installation, testing and commissioning of Inline Fan with direct/belt driven motor, belt guard, motor mount & vibration isolation type mounting. Casing shall be of 14 gauge steel sheet with min. 20 mm thick motor mounting plate. Vanes shall be Aerodynamically designed for max.efficiency the casing shall be bonderized, primed & coated with enamel paint. Hub & blades will be of Aluminium, blades shall be Aerofoil section for max. efficiency. Max clearance between blade tip & fan housing shall be 5 mm. The blade shall be tested at speed of 25% above the design operation speed. Motor shall be IE2 415/220 + 10% volts, 50 cycles,3 phase with class B insulation. Max. speed of motor shall be 1500 RPM, complete as per specifications & drawings. Fan should be complete with fire retardant, water proof double flexible connection between fan & duct.

-

-

-

... More
INDOOR STADIUM TOILET EXHAUST

-

-

-

... More
Capacity: 1000 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

2

-

-

... More
SPORT COMPLEX TOILET EXHAUST

-

-

-

... More
Capacity: 1000 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

2

-

-

... More
TOILET EXHAUST

-

-

-

... More
Capacity: 1500 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

1

-

-

... More
JCO GYM TOILET EXHAUST

-

-

-

... More
Capacity: 1000 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

2

-

-

... More
Capacity: 1700 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

2

-

-

... More
AUDITORIUM TOILET EXHAUST FAN

-

-

-

... More
Capacity: 300 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

1

-

-

... More
TOILET EXHAUST FAN

-

-

-

... More
Capacity: 500 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

1

-

-

... More
TOILET EXHAUST FAN

-

-

-

... More
Capacity: 800 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

1

-

-

... More
TOILET EXHAUST FAN

-

-

-

... More
Capacity: 1500 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

2

-

-

... More
SHOPPLING COMPLEX TOILET EXHAUST

-

-

-

... More
Capacity: 1000 CFM Static Presure : 20 mm Of wg Kw : 0.7 KW

2

-

-

... More
MECHNICAL VENTILATION SYSTEM

-

-

-

... More
VANE AXIAL FLOW FANS WITH SOUND ATTENUATOR FOR NORMAL MODE AS WELL AS FIRE MODE VENTILATION (FRESH AIR FAN ) (UL LISTED FANS ) Supply, installation, testing & commissioning of floor mounted double flanged, long casing (motor should completly accomodated in Fan casing) axial flow fans AMCA Certified, with adjustable pitch blade & angle ,bird screen at fan inlet, MS/GI casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4/6/8pole, three Phase, A.C supply class "F" insulation with support, Phase& Motor rated Value IP55. with the Approx. Motor HP as given below ( to be supported with Documentary evidence at the time of Technical Bid.) The rate shall include supply and fitting of vibration isolators ( spring & rubber pads) complete as per specifications and drawings including fitting of accessories like Fire retardant canvass connection painting,gravity louver,bird screen etc. as required at site of work. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc

-

-

-

... More
Note:- 1. Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager. 2. Fan motor shall meet IE2 standard as per IS-12615 3. Thickness of casing : for dia( 315-630 )mm - 2mm, dia ( 710-1120)mm - 3mm, dia (1250-1400)mm - 4mm & dia 1600mm - 5mm.

-

-

-

... More
AUDITORIUM FOR STAGE

-

-

-

... More
Air Qty. = 11500 CFM Static Pressure = 30 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = Not exceeding 5.5 Kw.

1

-

-

... More
FOR AUDITORIUM

-

-

-

... More
Air Qty. = 25000 CFM Static Pressure = 30 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = Not exceeding 15 Kw.

1

-

-

... More
VANE AXIAL FLOW FANS WITH SOUND ATTENUATOR FOR NORMAL AS WELL AS FIRE MODE FAN (EXHAUST AIR ) (UL LISTED FANS ) Supply, installation, shifting, loading, unloading, testing & commissioning of Floor mounted, double flanged, long casing (motor should completly accomodated in Fan casing) Vane axial flow fans with sound attenuator (Fire Rated) AMCA Certified, with adjustable pitch blade & angle, bird screen at fan outlet, dmbs, MS/GI casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4/6/8 pole, three Phase, A.C supply class "H" /S insulation with support, Phase& Motor rated Value IP55 . Motor shall be Thermally Rated for 250 deg C for 2 Hours should be certified as per BSEN12101-3:2002 standard & direct driven for smoke extraction fans. With the Approx. Motor HP as given below (to be supported with Documentary evidence at the time of Technical Bid.) The rate shall include supply and fitting of vibration isolators ( spring & rubber pads) complete as per specifications and drawings including fitting of accessories like Fire retardant canvass connection painting,gravity louver,bird screen etc. as required at site of work. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc Sound attenuator shall be as specified with following characteristics:

-

-

-

... More
a) Length not exceeding 1D (Fan Dia.) b) Pressure drop through through sound attenuator shall not exceed 8mm WC Note:1 1. Outlet Velocity for normal mode fans not to exceed 14.0 MPS 1. Outlet Velocity for Fire mode fans not to exceed 18.0 MPS 2. Total efficiency of normal fans shall not less than 60% 3. Fan motor shall meet IE2 standard as per IS-12615 4. Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager. Sound attenuator shall be as specified with following characteristics: 5. Thickness of casing : for dia (315-630) mm - 2mm, dia (710-1120) mm - 3mm, dia (1250-1400)mm - 4mm & dia 1600mm - 5mm. 6. In case of attenuator, calculation of reduction of sound level with insertion loss of attenuator is to be submitted.

-

-

-

... More
JCO BLOCK BASEMENT VENTILATION IN CASE OF NORMAL MODE AS WELL AS FIRE MODE VENTILATION WITH SOUND ATTEUNATOR

-

-

-

... More
JCO BASEMENT Fan Capacity = 28500 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 7.5 KW Noise level = not exceed 70 db. at 3 meter distance

4

-

-

... More
OR'S BLOCK

-

-

-

... More
BASEMENT VENTILATION IN CASE OF NORMAL MODE VENTILATION WITH SOUND ATTEUNATOR (OR-1 & OR-2)

-

-

-

... More
Fan Capacity = 13000 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 11 KW Noise level = not exceed 70 db. at 3 meter distance

4

-

-

... More
(OR-3 & OR-4)

-

-

-

... More
Fan Capacity = 13000 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 11 KW Noise level = not exceed 70 db. at 3 meter distance

4

-

-

... More
TYPE V

-

-

-

... More
BASEMENT VENTILATION IN CASE OF NORMAL MODE AS WELL AS FIRE MODE VENTILATION WITH SOUND ATTEUNATOR

-

-

-

... More
ZONE 01 & 02 Fan Capacity = 30000 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 11 KW Noise level = not exceed 70 db. at 3 meter distance

4

-

-

... More
AUDI BASEMENT & ABOVE AREA BASEMENT VENTILATION IN CASE OF NORMAL MODE VENTILATION WITH SOUND ATTEUNATOR

-

-

-

-

-

-

... More
Fan Capacity = 16000 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 11 KW Noise level = not exceed 70 db. at 3 meter distance

4

-

-

... More
FOR LOBBY AREA

-

-

-

... More
Air Qty. = 7500 CFM Static Pressure = 30 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = Not exceeding 5.5 Kw.

1

-

-

... More
FOR STAGE

-

-

-

... More
Air Qty. = 11500 CFM Static Pressure = 30 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = Not exceeding 5.5 Kw.

1

-

-

... More
FOR AUDITORIUM

-

-

-

... More
Air Qty. = 25000 CFM Static Pressure = 30 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = Not exceeding 15 Kw.

1

-

-

... More
PRESSURIZATION FANS FOR FRESH AIR TUBE AXIAL FLOW FANS FOR PRESSURIZATION(FRESH AIR FAN ) Supply, installation, testing & commissioning of Floor mounted/ceiling suspended double flanged, long casing (motor should completly accomodated in Fan casing) axial flow fans AMCA Certified, with adjustable pitch blade & angle ,bird screen at fan inlet, MS/GI casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3%, 4/6/8pole, three Phase, A.C supply class "F" insulation with support, Phase & Motor rated Value IP55. with the Approx. Motor HP as given below (to be supported with Documentary evidence at the time of Technical Bid). The rate shall include supply and fitting of vibration isolators (spring & rubber pads) complete as per specifications and drawings including dmbs, fitting of accessories like Fire retardant canvass connection painting, gravity louver,bird screen etc. as required at site of work. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc.

-

-

-

... More
Note:- 1. Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager. 2. Fan motor shall meet IE2 standard as per IS:12615 3. Thickness of casing : for dia (315-630) mm - 2mm, dia (710-1120) mm - 3mm, dia (1250-1400) mm - 4mm & dia 1600mm - 5mm.

-

-

-

... More
LIFT LOBBY PRESSURIZATION

-

-

-

... More
JCO BLOCK

-

-

-

... More
Fan Capacity = 6500 CFM Static Pressure = 20 mm Wg Motor Rating = Not Exceed 3.7KW Noise level = not exceed 85 db at 3 meter distance

2

-

-

... More
Fan Capacity = 8500 CFM Static Pressure = 20 mm Wg Motor Rating = Not Exceed 3.7KW Noise level = not exceed 85 db at 3 meter distance

1

-

-

... More
OR-01 & 02

-

-

-

... More
Fan Capacity = 8500 CFM Static Pressure = 20 mm Wg Motor Rating = Not Exceed 3.7KW Noise level = not exceed 85 db at 3 meter distance

4

-

-

... More
OR-03 & 04

-

-

-

... More
Fan Capacity = 8500 CFM Static Pressure = 20 mm Wg Motor Rating = Not Exceed 3.7KW Noise level = not exceed 85 db at 3 meter distance

4

-

-

... More
TYPE V

-

-

-

... More
Fan Capacity = 6500 CFM Static Pressure = 20 mm Wg Motor Rating = Not Exceed 3.7KW Noise level = not exceed 85 db at 3 meter distance

2

-

-

... More
LIFT WELL PRESSURIZATION

-

-

-

... More
TYPE V

-

-

-

... More
Fan Capacity = 12500 CFM Static Pressure = 20 mm Wg Motor Rating = Not Exceed 5.5KW Noise level = not exceed 85 db at 3 meter distance

6

-

-

... More
JCO BLOCK

-

-

-

... More
Fan Capacity = 6000 CFM Static Pressure = 20 mm Wg Motor Rating = Not Exceed 3.7KW Noise level = not exceed 85 db at 3 meter distance

4

-

-

... More
Fan Capacity = 12500 CFM Static Pressure = 20 mm Wg Motor Rating = Not Exceed 5.5KW Noise level = not exceed 85 db at 3 meter distance

6

-

-

... More
OR-01 & 02

-

-

-

... More
Fan Capacity = 12500 CFM Static Pressure = 20 mm Wg Static Pressure = 20 mm Wg Noise level = not exceed 85 db at 3 meter distance

12

-

-

... More
OR-03 & 04

-

-

-

... More
Fan Capacity = 12500 CFM Static Pressure = 20 mm Wg Motor Rating = Not Exceed 7.5KW Noise level = not exceed 85 db at 3 meter distance

12

-

-

... More
STAIRCASE PRESSURIZATION

-

-

-

... More
JCO BLOCK

-

-

-

... More
Fan Capacity = 13000 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 5.5KW Noise level = not exceed 85 db at 3 meter distance

1

-

-

... More
OR-01 & 02

-

-

-

... More
Fan Capacity = 13000 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 3.7KW Noise level = not exceed 85 db at 3 meter distance

2

-

-

... More
OR-03 & 04

-

-

-

... More
Fan Capacity = 13000 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 3.7KW Noise level = not exceed 85 db at 3 meter distance

2

-

-

... More
TYPE V

-

-

-

... More
Fan Capacity = 29000 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 5.5KW Noise level = not exceed 85 db at 3 meter distance

2

-

-

-

-

-

... More
Fan Capacity = 13000 CFM Static Pressure = 30 mm Wg Motor Rating = Not Exceed 3.7KW Noise level = not exceed 85 db at 3 meter distance

1

-

-

... More
PIPING WORK Supplying, laying/fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS:1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS:3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.

-

-

-

... More
Supply and Application of External Thermal Insulation on Chilled Water Piping with Closed Cell Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 55 Kg/m3, Thermal Conductivity of 0.037 W/mk at 20 Deg Celcius Mean Temp. and Mu≥7000 using manufacturer's recommended Rubber based Adhesive in a blend of solvents , Class 0 (BS 476 Part 6 & Part 7). Cladding of 230 μm in thickness with a total weight ≥340 g/m2 made from a 3- layer composite film of metallic appearance with aluminium intermediate layer and UV protection and having a permanent curl to be applied with 30-50mm overlap using plastic rivets and manufacturer's recommended 50mm PSA Tapes complete as per Specifications. All bends, T-sections and end caps shall be cladded with thermoformed fittings of the same composite covering system.

-

-

-

... More
(a) 150mm dia MS PIPE 50mm thick Insulation for 150mm dia MS PIPE

50

-

-

... More
(b) 125mm dia MS PIPE 50mm thick Insulation for 150mm dia MS PIPE

50

-

-

... More
(c) 100mm dia MS PIPE 50mm thick Insulation for 150mm dia MS PIPE

1000

-

-

... More
(d) 80mm dia MS PIPE 50mm thick Insulation for 150mm dia MS PIPE

125

-

-

... More
(e) 65mm dia MS PIPE 50mm thick Insulation for 150mm dia MS PIPE

90

-

-

... More
(f) 50mm dia MS PIPE 50mm thick Insulation for 150mm dia MS PIPE

85

-

-

... More
(g) 40mm dia MS PIPE 50mm thick Insulation for 150mm dia MS PIPE

110

-

-

... More
(h) 32mm dia MS PIPE 50mm thick Insulation for 150mm dia MS PIPE

80

-

-

... More
(j) 25mm dia MS PIPE 50mm thick Insulation for 150mm dia MS PIPE

65

-

-

... More
HIGH SIDE VALVES

-

-

-

... More
INSULATED VALVES Supplying, fixing, testing & commissioning of following valves, strainers, gauges in the chilled/Hot water plumbing duly insulated to the same specifications as the onnected piping and adequately supported as per specifications.

-

-

-

... More
Butterfly Valve (Manual) with CI Body SS disc, Nitrile Rubber Seal & O-Ring PN-16 presure rating for chilled water water circulation as specified.

-

-

-

... More
(a) 100 mm Dia (50 MM Thick Insulation )

12

-

-

... More
(b) 50 mm Dia (50 MM Thick Insulation )

8

-

-

... More
Mian Header

-

-

-

... More
(a) 100 mm Dia (50 MM Thick Insulation )

2

-

-

... More
(b) 50 mm Dia (50 MM Thick Insulation )

2

-

-

... More
Balancing Valve with built in flow measuring facility with CI Body flanged construction with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled/Hot water circulation as specified.

-

-

-

... More
(a) 100 mm Dia (75 MM Thick Insulation )

2

-

-

... More
(b) 50 mm Dia (75 MM Thick Insulation )

2

-

-

... More
"Y"strainer of ductile CI Body flanged ends with stainless steel strainer for chilled/hot water water circulation including insulation as specified.

-

-

-

... More
(a) 100 mm Dia (75 MM Thick Insulation )

4

-

-

... More
(b) 50 mm Dia (75 MM Thick Insulation )

2

-

-

... More
Non- return Valve with dual plate of CI Body SS Plates vulcanised NBR seal flanged end & PN16 pressure rating for chilled/Hot water circulation including insulation as specified.

-

-

-

... More
(a) 100 mm Dia (75 MM Thick Insulation )

4

-

-

... More
(b) 50 mm Dia (75 MM Thick Insulation )

2

-

-

... More
Providing & Fixing in position the mercury in glass industrial type thermometer complete as required.

8

-

-

... More
Providing & Fixing in position the industrial type pressure gauge complete as required.

8

-

-

... More
Supply, installation, testing, & commissioning of Automatic air vent with ball valve in brass construction complete with nipples, union etc. as required at all high points in the pipe lines. The valve shall be such as to have non-return valve as integral part of the vent. a) 12 mm dia auto air vent valve

5

-

-

... More
Supply, installation, testing & Commissioning of 25mm diameter Drain Valves in dirt legs complete with nipples as per specifications.

2

-

-

... More
Supply, installation, testing and commissioning of duly insulated with 80mm thick (40mm in two layers) expanded polystrene P quality with aluminium cladded open type expansion tank made out of 5 mm thick MS sheet of size 1.0mt x1.0mt x 1.0mt inner surface area epoxy paint two coats to avoid rust complete with all accessories valves & fittings for chilled water as per specs.

1

-

-

... More
LOW SIDE VALVES

-

-

-

... More
Supply, installation, testing and commissioning of following Ball Valve PN 16 rating duly insulated with Al Cladded valves as per pipe dia as detailed above, complete with companion flanges, nuts, bolts, gaskets etc.as specified confirming to specification.

-

-

-

... More
(a) 32 mm dia

6

-

-

... More
(b) 40 mm dia

2

-

-

... More
Supply, installation, testing and commissioning of following Butterfly Valve PN 16 rating duly insulated with Al Cladded valves etc of same rating as per pipe dia as detailed above, complete with companion flanges, nuts, bolts, gaskets etc. as specified confirming to specification.

-

-

-

... More
(a) 50 mm dia

6

-

-

... More
(b) 65 mm dia

12

-

-

... More
Supply, installation, testing and commissioning of "Y" type strainer following PN 16 rating duly insulated with Al Cladded valves etc of same rating as per pipe dia as detailed above, complete with companion flanges, nuts, bolts, gaskets etc.as specified confirming to specification.

-

-

-

... More
(a) 32 mm Dia

3

-

-

... More
(b) 40mm Dia

1

-

-

... More
(c) 50mm Dia

3

-

-

... More
(d) 65 mm Dia

6

-

-

... More
AHU's Controls/Dynamic Balancing Valves,Supply, Installation, Testing and commissioning of complete controls for AHUs comprising of self balancing, pressure independent, diaphragm type dynamic balancing valve with integrated 2 way modulating control valves in a single body. The actuator shall be capable of accepting 2-10VCD, 4-20mA electric signal and shall provide similar transduced feedback output sgnal to control system. The minimum close off pressure of actuator must be 1.5 times shut off head of pump as per specifications and drawing of following sizes.

-

-

-

... More
(a) 25 mm Dia

3

-

-

... More
(b) 32 mm Dia

1

-

-

... More
(c) 40 mm Dia

3

-

-

... More
(d) 50 mm Dia

6

-

-

... More
Supply, installation, testing & commissioning of Automatic air vent with ball valve in brass construction complete with nipples, union etc. as required at all high points in the pipe lines. The valve shall be such as to have non-return valve as integral part of the vent. a) 15 mm dia auto air vent valve

8

-

-

... More
Supply, installation, testing & commissioning of 25mm diameter Drain Valves in dirt legs complete with nipples as per specifications.

4

-

-

... More
Supply, installation , testing & commissioning of 13mm nitrile rubber Class O insulated condensate drain water piping of GI 'Medium' class complete with Medium Class fittings like elbows, tees, reducers bends, MS flanges, supports, welding, painting etc. as required conforming

-

-

-

... More
(a) 32 mm dia pipe

150

-

-

... More
(b) 25 mm dia pipe

200

-

-

... More
VRF/VRV REFRIGRENT PIPING Supply & fixing of interconnecting copper refrigerant pipe work (19mm / 13mm thick) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. All piping inside the room shall be properly supported on MS Slotted trays & all external piping shall run in covered slotted tray.

-

-

-

... More
(a) 41.1 mm O.D. (insulation - 19 mm thick)

20

-

-

... More
(b) 34.9 mm O.D. (insulation - 19 mm thick)

30

-

-

... More
(c) 28.6 mm O.D. (insulation – 19 mm thick)

117

-

-

... More
(d) 22.2 mm O.D. (insulation – 19 mm thick)

10

-

-

... More
(e) 19.1 mm O.D. (insulation – 13 mm thick)

20

-

-

... More
(f) 15.9 mm O.D. (insulation – 13 mm thick)

117

-

-

... More
(g) 12.7mm O.D. (insulation – 13 mm thick)

20

-

-

... More
(h) 9.5 mm O.D. (insulation – 13 mm thick)

20

-

-

... More
Providing and fixing of PVC drain water piping complete with fittings, support as per specification and insulated with 6 mm thick closed cell elastomeric nitile rubber insulation.

-

-

-

... More
(a) 40 mm dia O.D

330

-

-

... More
(b) 32 mm dia O.D

350

-

-

... More
(c) 25 mm dia O.D

250

-

-

... More
Supply, fabrication, installation and testing of sheet metal ducts (SITE FABRICATED DUCTS) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods, Gripple wire based support, anchor bolts, GI bolts & nuts, etc., as per specifications.

-

-

-

... More
(a) 26 gauge galvanized sheet steel

183

-

-

... More
(b) 24 gauge galvanized sheet steel

820

-

-

... More
(c) 22 gauge galvanized sheet steel

511

-

-

... More
(d) 20 gauge galvanized sheet steel

284

-

-

... More
(e) 18 gauge galvanized sheet steel

308

-

-

... More
Supply, fabrication, installation and testing of sheet metal ducts (Factory FABRICATED DUCTS) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods, Gripple wire based support, anchor bolts, GI bolts & nuts, etc., as per specifications.

-

-

-

... More
(a) 26 gauge galvanized sheet steel

788

-

-

... More
(b) 24 gauge galvanized sheet steel

3246

-

-

... More
(c) 22 gauge galvanized sheet steel

2000

-

-

... More
(d) 20 gauge galvanized sheet steel

953

-

-

... More
(e) 18 gauge galvanized sheet steel

694

-

-

... More
Supply, fabrication, installation and testing of 50 micron powder coated, aluminum extruded linear fixed horizintal bar/grill with all side flanges as per approved shop drawings.

122

-

-

... More
Supply, Installation and Testing of multiblade box type GSS construction of volume control damper to be provided with suitable links and quadrants for control of volume of air.

43

-

-

... More
Supply, Installation and Testing of 50 micron powder coated, Al extruded volume control damper for collor to be provided with suitable links and quadrants for control of volume of air.

109

-

-

... More
Supply, fabrication, installation and testing of 50 micron powder coated, aluminum extruded fresh air louvers with bird screen & Al volumne control damper with all side flanges as per approved shop drawings.

61

-

-

... More
Supply and fabrication of angle iron frame, mountings for installation/mounting of fans. The mounting frame work to be fabricated / made out of M.S. channel, angle iron, including providing all necessary hardware for completing the installation work, painting with two coats of red oxide primer and one coat of pre approved paint.

50

-

-

... More
Supply, installing, testing of fire retardant flexible canvass connector 150 mm deep made of imported FIBER GLASS WEAVE fabric with Silicon Rubber Coating & 30 mm Extruded Aluminum Frame.

40

-

-

... More
Fire Dampers Supply, installation, testing & commissioning of Duct/Wall mounted multi blade, motorised fire & smoke dampers with spring return actuator. The damper shall be of atleast 1.5 hr. fire rating and actuated with the help of 24 V electric actuator excluding. The damper shall be as per UL listed UL 555; 1995 and CBRI approved. The damper shall be constructed out of 16G galvanised steel sheet & as per specification with Control Cable to Potential Free Contact for tripping of AHU fan motor.

2

-

-

... More
Damper Actuator Supply, installation, testing and commissioning of Motorised Spring Return Actuator for devices upto 0.8 sq. metre with with control panel & temperature sensor.

11

-

-

... More
EYE BALL/JET NOZZLE WITH BUTTERFLY DAMPER Supply, installation and testing of 50 micron Powder coated Aluminium extruded eye Ball/Jet Nozzle with Butterfly damper .The noise level for jet nozzles shall shall not exceed 35 db for air quantity & throw as specified. Jet nozzles shall be of approved colour & shade of following sizes: Eye ball/Jet Nozzle 315 Dia with damper

35

-

-

... More
Supply, installation, testing and commissioning of 50miron Powder coated Aluminium extruded Diffuser drawing Circuler Diffuser 300 Dia. Neck Size with Butterfly Damper

30

-

-

... More
INSULATION WORK. Supply & Installation of Thermal Insulation on Duct using Closed Cell Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 60 Kg/m3, Thermal Conductivity of 0.037 W/mk at 20 Deg Celcius Mean Temp. and Mu≥50000 and with Factory Laminated Aluminium Foil of 60 microns using manufacturer's recommended Rubber based Adhesive in a blend of solvents complete as per Specifications

-

-

-

... More
(a) 16mm thick Class O Nitrile Rubber Insulation with Alu Foil of 60 microns

300

-

-

... More
(b) 13mm thick Class O Nitrile Rubber Insulation with Alu Foil of 60 microns

50

-

-

... More
ACOUSTIC INSULATION - FOR DUCT Supply and Application of Acoustic Insulation Inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7 and with built-in EPA approved Microban antimicrobial protection; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents. a) 15 mm thickness (Internal Lining of Ducts)

50

-

-

... More
Supply and Application of Acoustic Insulation Inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7 and with built-in EPA approved Microban antimicrobial protection to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents. Metal Strips and Anchor Fasteners as per design. ( 25 MM Thickness)

500

-

-

... More
Supply and fixing of 25mm Thick nitrile rubber Class O insulation for exposed roof area as shown in the drawings. Quoted price shall be inclusive of adhesive, two coat of pimer, nut etc. as required and as per the specifications.

500

-

-

... More
ELECTRICAL PART

-

-

-

... More
CUBICAL PANEL BOARD Supply, installation, testing and commissioning of wall mounted panels constructed out of 2mm thick CRCA sheet duly powder coated as per specifications. The panel shall have hinged door with on-off interlocks. The panel shall be complete with incoming MCCB, suitable bus bars of aluminum construction, bus links complete with Star delta starter with 'hands", "off", automatic modeselection switch, ammeter for each motor, timer, Auto Manual switch, remote start/stop contacts, earthing connector etc.,as required complete as per specifications. Panel should have following: Indicating lights LED for incommer and outgoing Ammeter with selector switch Volt meter with selector switch with fuse Panel With following Capacities:

-

-

-

... More
INDOOR STADIUM

-

-

-

... More
Fan 5.0 HP TP MPCB of suitable rating with 5.0 HP VFD PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

6

-

-

... More
Fan 7.5 HP TP MPCB of suitable rating with 7.5HP VFD PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on/off/trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

8

-

-

... More
SPORT COMPLEX

-

-

-

... More
Fan 3.0 HP TP MPCB of suitable rating with 3.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

5

-

-

... More
Fan 5.0 HP TP MPCB of suitable rating with 5.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

2

-

-

... More
Fan 7.5 HP TP MPCB of suitable rating with 5.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

1

-

-

... More
JCO BLOCK

-

-

-

... More
Fan 3.0 HP TP MPCB of suitable rating with 3.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

4

-

-

... More
Fan 5.0 HP TP MPCB of suitable rating with 5.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

7

-

-

... More
Fan 7.5 HP TP MPCB of suitable rating with 7.5 HP Star delta PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

7

-

-

... More
Fan 10 HP TP MPCB of suitable rating with 10 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

4

-

-

... More
OR BLOCK 01 TO 04

-

-

-

... More
Fan 5.0 HP TP MPCB of suitable rating with 5.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

8

-

-

... More
Fan 7.5 HP TP MPCB of suitable rating with 7.5 HP Star delta PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

32

-

-

... More
Fan 10 HP TP MPCB of suitable rating with 10 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

4

-

-

... More
TYPE V

-

-

-

... More
Fan 5.0 HP TP MPCB of suitable rating with 5.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

2

-

-

... More
Fan 7.5 HP TP MPCB of suitable rating with 7.5 HP Star delta PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

6

-

-

... More
Fan 15 HP TP MPCB of suitable rating with 15 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

6

-

-

... More
AUDITORIUM

-

-

-

... More
Fan 2.0 HP TP MPCB of suitable rating with 2.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

2

-

-

... More
Fan 5.0 HP TP MPCB of suitable rating with 5.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

1

-

-

... More
For Axial Fan 7.5 HP TP MPCB of suitable rating with 7.5 HP Star delta PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

10

-

-

... More
Fan 20 HP TP MPCB of suitable rating with 20 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

1

-

-

... More
SHOPPING COMPLEX

-

-

-

... More
Fan 3.0 HP TP MPCB of suitable rating with 3.0 HP DOL Stater PANEL having overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver, Auto Manual Selector switch. MPCB shall be of 35KA

8

-

-

... More
VRF OUTDOOR UNITS PANEL

-

-

-

... More
1x18 HP OUTDOOR UNIT TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 25KA

3

-

-

... More
ISOLATORS Providing & fixing weather proof isolator with suitable rating near each outdoor unit, the prices should be inclusive of copper cabling from isolators to outdoor units.

3

-

-

... More
POWER CABLING Supplying, laying, effecting proper connections, testing & commissioning of the following sizes of 1.1 KV -Cross Linked Poly Ethelene armoured aluminium conductor cables conforming to relevant latest amended Indian Standards laid over MS supports & Cable Trays including clamping the cables to supports in an approved manner as required complete with all accessories.

-

-

-

... More
(a) 1x4.0 Cx 16 Sqm Al Conductor

38

-

-

... More
(b) 1x4.0Cx 35 Sqm Al Conductor

188

-

-

... More
(c) 1x4.0Cx 50 Sqm Al Conductor

75

-

-

... More
(d) 1x4.0Cx 70 Sqm Al Conductor

80

-

-

... More
(e) 4C x 6 Sq. mm

1625

-

-

... More
(f) 4C x 10 Sq. mm

2143

-

-

... More
(g) 4C x 16 Sq. mm

756

-

-

... More
COPPER CONTROL CABLING Supply and laying, testing and commissioning of following sizes of Copper conductor control cables with PVC conduit & fixing clamps and effecting proper connections to equipment etc. of following sizes :

-

-

-

... More
(a) 1x4.0Cx4 Sqm Cu Conductor

75

-

-

... More
(b) 1x4.0Cx10 Sqm Cu Conductor

88

-

-

... More
(c) 6C X 1.5 sqm

931

-

-

... More
(d) 6C X 2.5 sqm

508

-

-

... More
(e) 4C X 2.5 sqm

816

-

-

... More
(f) 2C X 1.5 sqm

1025

-

-

... More
Earthing Strip / Wires. Supply & laying of 8 SWG. GI wire. or in recess for loop earthing as required.

8600

-

-

... More
Supply & laying 25x5mm GI strip at 0.5mt below ground as strip earth electrde including connection/terminatng with GI nut, bolt, spring, washer etc. as required) jointing shall be done by overlapping & with 2 sets of brass nuts bolt & spring washer spaced at 50mm) a) 25mm x 5mm

4684

-

-

... More
PART-P : ARBORICULTURE / LANDSCAPING WORKS

-

-

-

... More
TREE PLANTATION

-

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : a) Holes 1.2 m dia and 1.2 m deep

1093

-

-

... More
Supplying and Stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

494

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

1483

-

-

... More
PLANTS

-

-

-

... More
(A) Supply and Stacking of approved Trees as per following with well developed root system, true to variety/type, disease free and healthy plant in Poly/HDPE bag having minimum height as below mentioned after the plantation from the surface of the ground at site work.

-

-

-

... More
Supply and stacking of Acacia auriculiformis plant of ht 150-165 cm in bag size of 25 cm as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and stacking of Alstonia scholaris plant of height 210-240 cm. in bag of size 25 cm as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and stacking of Chukrassia tabularis plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-charge.

50

-

-

... More
Supply and stacking of Ficus infectoria (Pilkhan) plant of height 180-210 cm. in big polybag of size 25 cm as per direction of the Engineer-in-charge.

60

-

-

... More
Supply and stacking of Mimusops elengi (Maulsri) plant of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the Engineer-in-charge.

30

-

-

... More
Supply and stacking of Grevillea robusta (Silver Oak) plant of height 180-195 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-charge.

200

-

-

... More
Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180-195 cm. in gunny bag of size 30 cm as per direction of the Engineer-in-charge.

60

-

-

... More
Supply and stacking of Putranjiva roxburghii plant of height 150-180 cm. in big polybag of size 25 cm as per direction of the Engineer-in-charge.

15

-

-

... More
Supply and Stacking of Terminalia mantaly plant at site with the height 180-210 cm. in poly bags of size 20 cm & as per direction of the Engineer-in-charge.

30

-

-

... More
Supply and stacking of Bauhinia purpurea (Kachnar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-charge.

70

-

-

... More
Supply and Stacking of Butea monosperma (Flame of the forest) plant at site with the height 180-210 cm. in big poly bags of size 30 cm & as per direction of the Engineer-in-charge.

20

-

-

... More
Supply and stacking of Delonix regia (Gulmohar) plant of height 180-210 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-charge.

23

-

-

... More
Supply and Stacking of Caesalpinia pulcherrima plant at site with the height 180-210 cm. in poly bags of size 25 cm & as per direction of the Engineer-in-charge.

20

-

-

... More
Supply and stacking of Callistemon lanceolatus plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-charge.

30

-

-

... More
Supply and stacking of Cassia fistula (Amaltash) plant of height 180-210 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-charge.

50

-

-

... More
Supply and stacking of Cassia javanica plant of height 180-210 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-charge.

15

-

-

... More
Supply and stacking of Jacaranda mimosifolia plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-charge.

55

-

-

... More
Supply and Stacking of Lagerstroemia speciosa (The queen’s flower) plant at site with the height 210-240 cm. in poly bags of size 25 cm & as per direction of the Engineer-in-charge.

30

-

-

... More
Supply and Stacking of Michelia champa (Golden Champa)plant at site with the height 150-180 cm. in poly bag of size 25 cm & as per direction of the Engineer -in-charge.

35

-

-

... More
Supply and Stacking of Neolamarckia cadamba (Kadamba) plant at site with the height 210-240 cm. in poly bags of size 30 cm & as per direction of the Engineer-in-charge.

15

-

-

... More
Supply and Stacking of Peltophorum pterocarpum plant at site with the height 210-240 cm. in big poly bags of size 25 cm & as per direction of the Engineer-in-charge.

30

-

-

... More
Supply and Stacking of Tabebuia spectabilis plant at site with the height 150-180 cm. in poly bags of size 20 cm & as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and stacking of Spathodea campanulata plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-charge.

20

-

-

... More
Supply and stacking of Plumeria alba plant of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the Engineer-in-charge.

60

-

-

... More
Supply and Stacking of Dypsis decaryi (Triangle palm) Palm plant at site with the ht. 210-240 cm. with 12 to 14 suckers, well developed, fresh and healthy with lush green foliage in 35 cm size of big poly bag & as per direction of the Engineer-in-charge.

10

-

-

... More
Supply and stacking of Foxtail palm plant of ht. 240-270 cm bottom girth 35-40 cm well developed in big size HDPE bags as per direction of the Engineer-in-charge.

30

-

-

... More
Supply and Stacking Travellar palm plant well developed with fresh & healthy leaves foliage at site with the 210 to 240 cm ht specimen plant in 40 cm bag & as per direction of the Engineer-in-charge.

30

-

-

... More
Providing and Roystonia regia (Royal Palm) plant well developed with fresh & healthy leaves foliage at site with the 210 to 240 cm ht specimen plant in 40 cm big bag & as per direction of the Engineer-in-charge.

30

-

-

... More
(B) Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material’s as per direction of Engineer in charge (excluding cast of plant & water ) a) Cost of plantation per trees plants

1093

-

-

... More
(C) Supply and stacking of Bamboo stick with the plant is the essential of the same height treated with anti-termite solution, tie with the stick at 3 Nos. Suitable places.

600

-

-

... More
SHRUBS PLANTATION (IN BEDS)

-

-

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering & finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)

496

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

55

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of Engineer-in-charge. (cost of sludge, dump manure and/ or good earth to be paid separately).

496

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

496

-

-

... More
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical) and as per direction of Engineer-in-charge.

827

-

-

... More
PLANTS

-

-

-

... More
(A) Supply and Stacking of approved Shrubs as per following with saplings of well developed root system, true to variety/type, disease free and healthy plant in Poly/HDPE bag having minimum height as below mentioned after the plantation from the surface of the ground at site work.

-

-

-

... More
Supply and stacking of plant Ficus panda of height 60-90 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the Engineer-in-charge.

1500

-

-

... More
Supply and Stacking of plant Hyemanocallis littorallis (spider lily) of height 45 -60 cm should be well developed, disease free and healthy, in HDPE/Poly bag & as per direction of the Engineer-in-charge.

500

-

-

... More
Supply and stacking of plant Caesalpinia pulcherrima species of height 45-60 cm. in poly bag & as per direction of the Engineer-in-charge.

400

-

-

... More
Supply and stacking of plant Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the Engineer-in-charge.

1500

-

-

... More
Supply and stacking of plant Hibiscus rosasinensis of height 60-75 cm. with 5-6 branches in poly bag of size 25 cm as per direction of the Engineer-in-charge.

700

-

-

... More
Supply and Stacking of plant Hibiscus variegated of height 45 -60 cm should be well developed, disease free and healthy, in HDPE/Poly bag & as per direction of the Engineer-in-charge.

500

-

-

... More
Supply and Stacking of plant Lemonia spectabilis of height 30-45 cm should be well developed, disease free and healthy, in Poly bag & as per direction of the Engineer-in-charge.

100

-

-

... More
Supply and stacking of plant Nerium oleander (kaner) of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm as per direction of the Engineer-in-charge.

700

-

-

... More
Supply and stacking of plant Tabernaemontana divaricata (Chandni double) of height 75-90 cm. with 4-5 branches in bag of size 25 cm as per direction of the Engineer-in-charge.

600

-

-

... More
Supply and Stacking Acalypha red plant of height 30 -45 cm should be well developed, disease free and healthy foliage, in Poly bag & as per direction of the Engineer-in-charge.

600

-

-

... More
Supply and stacking of plant Cassia biflora of height 60-75 cm. with 4-5 branches in poly bags of size 25 cm as per direction of the Engineer-in-charge.

600

-

-

... More
Supply and Stacking of plant Tecoma stans of height 45 -60 cm should be well developed, disease free and healthy, in HDPE/Poly bag & as per direction of the Engineer-in-charge.

700

-

-

... More
Supply and Stacking of Plumbago auriculata plant of height 45 -60 cm should be well developed, disease free and healthy, in HDPE/Poly bag & and as per direction of the officerin- charge.

1000

-

-

... More
Supply and stacking of plant Calliandra hybrida of height 75-90 cm. with 4-5 branches in bag of size 25 cm as per direction of the Engineer-in-charge.

800

-

-

... More
Supply and stacking of plant Jatropha multifida (red colour) of height 60-75cm. multibranched in p.bag of size 25 cm as per direction of the Engineer-in-charge.

500

-

-

... More
Supply and stacking of plant Largerstroemia indica of height 90-105 cm. multibranched in poly bags of size 25 cm as per direction of the Engineer-in-charge.

500

-

-

... More
Supply and stacking of plant Tabernaemontana coronaria (Chandni single) of height 75-90 cm. with 5-6 branches in bag of size 25 cm as per direction of the Engineer-in-charge.

1200

-

-

... More
(B) Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material’s as per direction of Engineer in charge (excluding cast of plant & water ) a) Cost of plantation per Shrubs plants

12400

-

-

... More
(C) Supply and stacking of Bamboo stick with the plant is the essential of the same height treated with anti-termite solution, tie with the stick at Suitable places.

3000

-

-

... More
SHRUBS PLANTATION (IN PITS)

-

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : a) Holes 60 cm dia, and 60 cm deep

2800

-

-

... More
Supplying and Stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).

314

-

-

... More
Supplying and Stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

157

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

476

-

-

... More
PLANTS

-

-

-

... More
(A) Supply and Stacking of approved shrubs as per following with saplings of well developed root system, true to variety/type, disease free and healthy plant in Poly/HDPE bag having minimum height as below mentioned after the plantation from the surface of the ground at site work.

-

-

-

... More
Supply and Stacking of Melaleuca bracteata (Black tea) 90-120 cm. in gunny bag of size 30 cm & as per direction of the Engineer-in-charge.

100

-

-

... More
Supply and Stacking Bird of paradise (Strelitzia reginae) plant well developed with fresh & healthy 90 to 120 cm ht in Poly bag & as per direction of the Engineer-in-charge.

200

-

-

... More
Supply and stacking of plant Tecoma gaudichaudi of height 90-105 cm.,bushy in big size HDPE bag as per direction of the Engineer-in-charge.

150

-

-

... More
Supply and Stacking plants Standard Rose (H.T. variety) 3 to 4 healthy branch 45-60 cm ht. well developed with one and above flowers in Poly bag & as per direction of the Engineer-in-charge.

300

-

-

... More
Supply and stacking of plant Ficus panda of height 60-90 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the Engineer-in-charge.

50

-

-

... More
Supply and Stacking of Ixora var.height 75-90 cm. in Poly bag & as per direction of the Engineer-in-charge.

150

-

-

... More
Supply and Stacking of Dracaena rosea plant, having ht. 45 cm & above with 8 to10 leaves, well developed, fresh and healthy in Poly bag & as per direction of the Engineer-in-charge.

200

-

-

... More
Supply and Stacking of Dracaena (Song of India Green) plant, having ht. 45 cm & above with 8 to10 leaves, well developed, fresh and healthy in Poly bag & as per direction of the Engineer-in-charge.

500

-

-

... More
Supply and Stacking of Dracaena (Kedarnath) plant, having ht. 45cm & above with 8 to10 leaves, well developed, fresh and healthy in Poly bag & as per direction of the Engineer-in-charge.

300

-

-

... More
Supply and Stacking of Dracaena (Margineta) plant, having ht. 45 cm & above with 8 to10 leaves, well developed, fresh and healthy in Poly bag & as per direction of the Engineer-in-charge.

150

-

-

... More
Supply and Stacking of Dracaena fragrans”Massangeana’’/ victoria plant/ waranickii plant plant, having ht. 45-60 cm with full of leaves, well developed, fresh and healthy in Poly bag & as per direction of the Engineer-in-charge.

300

-

-

... More
Supply and Stacking of Croton petra Bangalore variety plant, having ht. 60-75 cm with 4 to 6 branches, well developed, fresh and healthy colourfull leaves in Poly bag & as per direction of the Engineer-in-charge.

150

-

-

... More
Supply and Stacking of Croton spotlight variety plant, having ht. 60-75 cm with 4 to 6 branches, well developed, fresh and healthy colourfull leaves in Poly bag & as per direction of the Engineer-in-charge.

100

-

-

... More
Supply and Stacking of Mussaenda plant at site with the height 90-120 cm. in poly bags of size 25 cm & as per direction of the Engineer-in-charge.

150

-

-

... More
(B) Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material’s as per direction of Engineer in charge (excluding cast of plant & water) a) Cost of plantation per Shrubs plants

2800

-

-

... More
(C) Supply and stacking of Bamboo stick with the plant is the essential of the same height treated with anti-termite solution, tie with the stick at Suitable places.

1500

-

-

... More
ORNAMENTAL PLANTS (IN PITS)

-

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : a) Holes 60 cm dia, and 60 cm deep

960

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

54

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

163

-

-

... More
PLANTS

-

-

-

... More
(A) Supply and Stacking of aprroved plants as per following with well developed root system, true to variety/type, disease free and healthy plant in Poly/HDPE bag having minimum height as below mentioned after the plantation from the surface of the ground at site work.

-

-

-

... More
Supply and Stacking of plant Junipurse golden of height 75-90 cm., conical haped, well formed with healthy foliage in Poly bag & as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and Stacking Adenium Obesum plant well developed with fresh & healthy 4 to 5 branch 60 to 75 cm ht. in Poly abg & as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and Stacking Furcaria Variegated plant hybrid well developed with fresh & healthy foliage 10 and above attractive leaves in Poly bag & as per direction of the Engineer-in-charge.

30

-

-

... More
Supply and Stacking Nolino plant well developed with fresh & healthy foliage 20 and above attractive leaves in poly bag & as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and Stacking of Livistona palm plant, having ht. 60 cm to 75 cm, well developed with 8 to 10 leaves, fresh & healthy foliage in Poly bag & as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and Stacking Cycus cirsnallis plant well developed with fresh & healthy 35 to 40 lush green leaves in poly bag & as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and Stacking Cycus revoluta, specimen plant, having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed in poly bag/challi & as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and stacking of Ficus benjamina (green) plant of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the Engineer-in-charge.

150

-

-

... More
Supply and Stacking of Phoenix palm plant, having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in Poly bag & as per direction of the Engineer-in-charge.

100

-

-

... More
Supply and Stacking Ficus Starlight plant with fresh, healthy and attractive foliage 45 to 60 cm spread 75 to 90 cm ht., specimen bushy plant in Poly bag & as per direction of the Engineer-in-charge.

100

-

-

... More
Supply and stacking of Plumeria acutifolia plant of height 150-165 cm. with 3-4 branches in big size HDPE bag as per direction of the Engineer-in-charge.

50

-

-

... More
Supply and stacking of Plumeria rubra plant of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the Engineer-in-charge.

50

-

-

... More
Supply and Stacking Bamboo Buddha vally variety with umbrella shape plant having 120 to 135 ht. with fresh & healthy foliage well developed in Poly bag & as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and stacking of Washingtonia filifea palm plant stem ht. 90-105 cm with 6-7 healthy leaves lush green leaves well developed in big size HDPE Bags as per direction of the Engineer-in-charge.

25

-

-

... More
Supply and Stacking Bismarckia nobilis palm plant well developed 90 to 200 cm ht. having 5 to 6 straight fresh and healthy leaves in Poly bag & as per direction of the Engineer-in-charge.

20

-

-

... More
Supply and Stacking of Areca Palm plant, having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in Poly bag & as per direction of the Engineer-in-charge.

20

-

-

... More
Supply and Stacking of Raphis palm plant, having ht. 75 cm to 90 cm with 12 to 15 equal suckers, well developed, full of fresh & healthy leaves from bottom to top in Poly bag & as per direction of the Engineer-in-charge.

60

-

-

... More
Supply and Stacking Pine topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 150 to 180cm ht in poly bag & as per direction of the Engineer-in-charge.

20

-

-

... More
Supply and Stacking Ficus Panda topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 150 to 180cm ht in poly bag & as per direction of the Engineer-in-charge.

20

-

-

... More
Supply and Stacking Ficus Retusa topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 150 to 180cm ht in poly bag & as per direction of the Engineer-in-charge.

20

-

-

... More
Supply and Stacking Golden Bottle Brush topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 150 to 180cm ht in poly bag & as per direction of the Engineer-in-charge.

20

-

-

... More
Supply and Stacking of Ficus benjamina (black) plant of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the Engineer-in-charge.

100

-

-

... More
(B) Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cast of plant & water ) a) Cost of plantation per Trees plants

960

-

-

... More
LAWN PREPRATION

-

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

7800

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

429

-

-

... More
Rough dressing the trenched ground including breaking clods.

13000

-

-

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.

13000

-

-

... More
Fine dressing of the ground.

13000

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of Engineer-in-charge. (cost of sludge, dump manure and/ or good earth to be paid separately).

7800

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

7800

-

-

-

-

-

... More
Providing & laying Selection no.1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of Engineer in charge.

5000

-

-

... More
Supplying & Stacking of Selection No.1 Grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of Engineer in charge.

1870

-

-

... More
Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and earth shall be paid for separately). a) In rows 5 cm apart in both directions

7500

-

-

... More
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of Engineer-in-charge.

500

-

-

... More
HEDGE PLANTATION

-

-

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).

720

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

40

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of Engineer-in-charge. (cost of sludge, dump manure and/ or good earth to be paid separately).

720

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

720

-

-

... More
HEDGE PLANTS

-

-

-

... More
(A) Supply and Stacking of approved Hedges as per following with well developed root system, true to variety/type, disease free and healthy plant in Poly/HDPE bag having minimum height as below mentioned after the plantation from the surface of the ground at site work

-

-

-

... More
Supply and Stacking of Clerodendrum inerme plant of height 30 cm to 45 cm. in Poly bag & as per direction of the Engineer-in-charge.

800

-

-

... More
Supply and Stacking of plant Duranta broad leaf having ht.15 to 20 cm bushty shape plant with fresh and healthy leaves in Poly bag & as per direction of the Engineer-in-charge.

200

-

-

... More
EDGE PLANTS

-

-

-

... More
Supply and Stacking of Duranta Golden plant, having ht.15 to 20 cm bushty shape plant with fresh and healthy leaves in Poly bag & as per direction of the Engineer-in-charge.

200

-

-

... More
(B) Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cast of plant & water ) Cost of plantation per Hedges plants( 07 nos per RM)

1200

-

-

... More
GROUND COVER PLANTATION (IN BEDS)

-

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

750

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

41

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of Engineer-in-charge. (cost of sludge, dump manure and/ or good earth to be paid separately).

750

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

750

-

-

... More
PLANTS

-

-

-

... More
(A) Supply and Stacking of Ground Cover as per following with saplings of well developed root system, true to variety/type, disease free and healthy plant in Poly/HDPE bag having minimum height as below mentioned after the plantation from the surface of the ground at site work

-

-

-

... More
Supply and Stacking of Alternanthera (Red/Green/splendida) species plant of height 15 cm to 20 cm, full of branches and foliage in Poly bag & as per direction of the Engineer-in-charge.

230

-

-

... More
Supply and Stacking of Alpinia Variegated (three in one) plant having ht. 30 cm and above, with fresh and healthy variegated foliage in Poly bag & as per direction of the Engineer-in-charge.

50

-

-

... More
Supply and Stacking of Barleria cristata rosea plant of height 20 cm to 25 cm, bushy and multi-branches in Poly bag & as per direction of the Engineer-in-charge.

60

-

-

... More
Supply and Stacking of Wadelia trilobata plant,full of leaves in Poly bags & as per direction of the Engineer-in-charge.

250

-

-

... More
Supply and Stacking of Iresine herbstii plant, of height 20-30 cm., full of branches well developed in Poly bag & as per direction of the Engineer-in-charge.

350

-

-

... More
Supply and Stacking of Zebrina Trades cantia/ pendula plant having in Poly bag & as per direction of the Engineer-in-charge.

60

-

-

... More
Supply and Stacking of Verbena plant of height 15 cm to 20 cm, bushy and multi-branches in Poly bag & as per direction of the Engineer-in-charge..

200

-

-

... More
Supply and Stacking of Zephyranthes candida plant of height 15 cm to 20 cm, bushy and multi-branches in Poly bag & as per direction of the Engineer-in-charge..

50

-

-

... More
(B) Plantation of Ground Cover at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cast of plant & water ) Cost of plantation per Ground Cover plants (minimum 25 nos per Sqm)

1250

-

-

... More
GROUND COVER PLANTATION (IN PITS)

-

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : a) Holes 45 cm dia, and 45 cm deep

5350

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

123

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

375

-

-

... More
PLANTS

-

-

-

... More
(A) Supply and Stacking of approved Ground Cover as per following with saplings of well developed root system, true to variety/type, disease free and healthy plant in Poly/HDPE bag having minimum height as below mentioned after the plantation from the surface of the ground at site work.

-

-

-

... More
Supply and Stacking of Asparagus sprengeri plant of height 30 cm to 45 cm, full of leafy branches in Poly bag & as per direction of the Engineer-in-charge.

800

-

-

... More
Supply and Stacking of Juniperus prostrata/chinensis plant with 5 to 6 latral branches and green foliage in Poly bag & as per direction of the Engineer-in-charge.

400

-

-

... More
Supply and Stacking of Ophiopogon jaburan ( variegated ) plant,full of variegated leaves in Poly bag & as per direction of the Engineer-in-charge.

1200

-

-

... More
Supply and Stacking of Rhoeo gold plant, bushy and multi-branches in Poly bag & as per direction of the Engineer-in-charge..

800

-

-

... More
Supply and Stacking of Phalaris arundinacea plant of height 15 cm to 20 cm, bushy and multi-branches in Poly bag & as per direction of the Engineer-in-charge..

250

-

-

... More
Supply and Stacking of Dianella variegated plant, with 3 to 4 variegated leaves in Poly bag & as per direction of the Engineer-in-charge.

1000

-

-

... More
Supply and Stacking of Ferns plant of height 15 cm to 20 cm, bushy and multi-branches in Poly bag & as per direction of the Engineer-in-charge..

300

-

-

... More
Supply and Stacking of Asparagus marrie plant of height 30 cm to 45 cm, full of leafy branches in Poly bag & as per direction of the Engineer-in-charge.

600

-

-

... More
(B) Plantation of Ground Cover at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cast of plant & water ) Cost of plantation per Ground Cover plants

5350

-

-

... More
CREEPER PLANTATION (IN PITS)

-

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : a) Holes 45 cm dia, and 45 cm deep

2300

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

53

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

161

-

-

... More
PLANTS

-

-

-

... More
(A) Supply and Stacking of approved Creeper as per following with saplings of well developed root system, true to variety/type, disease free and healthy plant in Poly/HDPE bag having minimum height as below mentioned after the plantation from the surface of the ground at site work.

-

-

-

... More
Supply and stacking of Allamanda cathartica plant of height 30 cm to 45 cm. in Plastic pots & as per direction of the Engineer-in-charge.

50

-

-

... More
Supply and stacking of Bignonia venusta (Golden shower) plant of height 30 cm to 45 cm. in Plastic pots & as per direction of the Engineer-in-charge.

250

-

-

... More
Supply and Stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Varigata, Glabra Formosa, Peruviana Odissi, Partha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) plant of height 30 cm. to 45 cm. with 2-3 branches in Poly bag & as per direction of the Engineer-in-charge. .

750

-

-

... More
Supply and Stacking of Climbing roses plant of height 30 cm. to 45 cm. with 2-3 branches in Poly bag & as per direction of the Engineer-in-charge. .

50

-

-

... More
Supply and Stacking of Vernonia elaegnifolia (curtain creeper) plant of height 30 cm to 45 cm. in Poly bag & as per direction of the Engineer-in-charge.

300

-

-

... More
Supply and stacking of Madhumalti plant, branches in Poly bag & as per direction of the Engineer-in-charge.

800

-

-

... More
Supply and stacking of Jacomonsia plant, branches in Poly bag & as per direction of the Engineer-in-charge.

100

-

-

... More
(B) Plantation of Creeper at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cast of plant & water) Cost of plantation per Creeper plants

2300

-

-

... More
FLOWERING BED PLANTATION (IN BEDS)

-

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

300

-

-

... More
Supplying and Stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

20

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of Engineer-in-charge. (cost of sludge, dump manure and/ or good earth to be paid separately).

300

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.

300

-

-

... More
PLANTS

-

-

-

... More
(A) Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each pro tray having 100 Nos plants as per direction of the Engineer-in-charge.

-

-

-

... More
Alyssum

3

-

-

... More
Calendula double

5

-

-

... More
Chrysenthemum Double

3

-

-

... More
Cineraria

5

-

-

... More
Dahlia double

3

-

-

... More
Marigold French Hybrid dwarf

5

-

-

... More
Pansy Hybrid

3

-

-

... More
Petunia hybrid

3

-

-

... More
Phlox mix colour hybrid

5

-

-

... More
Salvia

5

-

-

... More
Stock double

3

-

-

... More
Kochia

5

-

-

... More
Cosmos hybrid

3

-

-

... More
(B) Plantation of winter seasonal seedling/cutting at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cast of plant & water ) Cost of plantation ( 10-15 nos per RM)

510

-

-

... More
Providing and Displaying of plant Chrysenthemum double variety, well developed, having 45 to 60 cm ht., with 6 and above flowers with half blooming condition, fresh and healthy with bamboo stacking in 25 cm Earthen Pot and as per direction of the Engineer-in-charge.

150

-

-

... More
Providing and Displaying plants Coleus broad leaves having 5 to 6 branches equal well developed with fresh & healthy foliage in different colour in 25 cm Earthen Pot/Plastic Pot and as per direction of the Engineer-in-charge.

50

-

-

... More
Providing and Displaying of plant Dahlia double kenya variety in different colour well developedwith 3 to 4 flowers in half bloom, good foliage stacked with Green painted Bamboo sticks, 45to 60 cm height in 25 cm Earthen Pot/Plastic Pot and as per direction of the Engineer-in-charge.

150

-

-

... More
Providing and Displaying plants Marigold jaffri dwarf in different colour well developed with fresh & healthy foliage with 12 to15 flowers in bloom specimen plant 23to 30 cm ht in 20 cm Earthen Pot/Plastic Pot and as per direction of the Engineer-in-charge.

100

-

-

... More
Providing and Displaying plants Cockscomb well developed fresh & healthy 20 to 25 cm ht. attractive colours fully bloomed in 20 cm Earthen Pot/Plastic Pot and as per direction of the Engineer-in-charge.

100

-

-

... More
Providing and Displaying plants Pansy Hybrid Sakata well developed with fresh & healthy foliage with 3 to 4 flower in bloom in 20 cm Earthen Pot/Plastic Pot and as per direction of the Engineer-in-charge.

200

-

-

... More
POTTED PLANTS (INDOOR PLANTS)

-

-

-

... More
(A) Supply and Displaying of the following well developed root system, true to variety/type, disease free and healthy plant having minimum height as below mentioned at site work

-

-

-

... More
Providing and Displaying of Araucaria cookie plant, having ht. 1.20 m to 1.35 m, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 25 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

100

-

-

... More
Providing and Displaying of Areca palm plant, having ht. 1.50 m to 1.80 m with 6 to 8 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

100

-

-

... More
Providing and Displaying of Aglaonema Snow-White hybrid plant (three in one), having ht. 30 cm & above with 6 to 8 leaves, bright colour, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot. (Specimen Plant) & as per direction of the Engineer-in-charge.

50

-

-

... More
Providing and Displaying of Dieffenbachia meaclata plant, having ht. 45 cm to 60 cm with 5 and above leaves, well developed, fresh and healthy & attractive variegated foliage in 25 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

50

-

-

... More
Providing and Displaying of Sedum plant of height 15 cm to 20 cm, bushy and multi-branches in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the Engineer-in-charge.

50

-

-

... More
Providing and Displaying of Money Plant Broad Leaves mounted on moss stick 1.20 m ht., 5 to 6 plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

35

-

-

... More
Providing and displaying of Croton Golden specimen plant, having ht. 90cm to 1.05 cm with 5 to 6 branches, well developed, fresh and healthy foliage in 30 cm size of Earthen pot / Plastic pot as per direction of the Engineer-in-charge.

100

-

-

... More
Providing and Displaying of Oxycardium green mounted on moss stick 1.20 m ht., 5 to 6 plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

50

-

-

... More
Providing and Displaying of Oxycardium yellow mounted on moss stick 1.20 m ht., 5 to 6 plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

50

-

-

... More
Providing and displaying of Schefflera Green plant (three in one), mounted on moss stick 90 cm, well developed with full of fresh & healthy leaves from bottom to top with rich foliage in 25 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

30

-

-

... More
Providing and displaying of Syngonium golden plant, mounted on moss stick 90 cm ht., 3 to 4 plants placed in each pot at equal distance, well developed with full of fresh & healthy leaves from bottom to top in 25 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

30

-

-

... More
OUTDOOR PLANTS

-

-

-

... More
Providing and displaying of Areca Palm plant, having ht. 2.40 m to 2.70 m with 12 to 14 suckers, well developed, fresh and healthy with lush green foliage in 35 cm size of Bucket type cement pots & as per direction of the Engineer-in-charge.

25

-

-

... More
Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy plant in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the Engineer-in-charge.

50

-

-

... More
Providing and Displaying of Raphis palm plant, having ht. 75 cm to 90 cm with 12 to 15 equal suckers, well developed, full of fresh & healthy leaves from bottom to top in 25 cm size Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

100

-

-

... More
Providing and Displaying Cycus revoluta in 35 cm challi, specimen plant, having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the Engineer-in-charge.

15

-

-

... More
Providing and Displaying of Plumeria alba plant of height 165-180 cm. with 3-4 branches and thick stem in big size in 36 cm Cement Pot as per direction of the Engineer-in-charge.

25

-

-

... More
Providing and Displaying of ficas long islend topari well developed with fresh and healthy 5 to 6 ball specific size and safe 120 to 150cm height in 40cm cement pot as per direction of the Engineer-in-charge.

6

-

-

... More
Providing and Displaying of ficas retusa topari well developed with fresh and healthy 5 to 6 ball specific size and shape180 to 210cm height in 40cm cement pot as per direction of the Engineer-in-charge.

6

-

-

... More
Providing and Displaying of fishtail palm well developed with fresh and healthy foliage leaves of ht 210 to 240cm specificimen in 35cm cement pot as per direction of the Engineer-in-charge.

15

-

-

... More
Providing and Displaying of topari of casuarina fresh and healthy 5 to 6 specific shape and size ball well developed 195 to 210cm height in 40cm cement pot as per direction of the Engineer-in-charge.

6

-

-

... More
Providing and Displaying of Bamboo buddha vally variety with umbrella shape hahing 122 to 135ht with fresh and healthy foliage well developed 40cm cement pot as per direction of the Engineer-in-charge.

10

-

-

... More
GROUPING PLANTS

-

-

-

... More
Providing and Displaying of Ixora var.height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the Engineer-in-charge.

100

-

-

... More
Providing and Displaying of Asparagus marrie plant, well developed 15 to 20 leaves, full of branches and foliage in 25 cm size of Earthen Pot / Plastic Pot & as per direction of the Engineer-in-charge.

250

-

-

... More
Providing and Displaying Begonia plant well developed with fresh & healthy foliage 10 and above attractive leaves in 20 cm Cement Pot as per direction of the Engineer-in-charge.

150

-

-

... More
Providing and Displaying of croton petra plant, having ht. 45 cm & above with 2 to 3 branches, well developed, fresh and healthy leaves in 25 cm size of Earthen pot / Plastic pot.

100

-

-

... More
Providing and Displaying of Dracaena rosea plant, having ht. 30 cm & above with 8 to10 leaves, well developed, fresh and healthy in 20 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

100

-

-

... More
Providing and displaying of Draceana Song of India Green plant (three in one), having ht. 30 cm, well developed, fresh & healthy, lush green foliage from bottom to top in 20 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

150

-

-

... More
Providing and Displaying of Dracaena (Kedarnath) plant, having ht. 30 cm & above with 8 to10 leaves, well developed, fresh and healthy in 20 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

150

-

-

... More
Providing and displaying of Dracaena margineta plant, having ht. 30 cm to 45 cm with colourfull leaves, fresh and healthy in 20 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

100

-

-

... More
Providing and Displaying of Ribbon grass having ht. 30 cm & above with 8 to10 leaves, well developed, fresh and healthy in 20 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-charge.

200

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer,dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Engineer-in-charge.

200

-

-

... More
Providing & fixing of White River (Stone) Pables size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.

100

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

200

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

100

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge.

100

-

-

... More
Supplying of 12" Dia. size of FRP Circular pot in White color with 12" ht. & as per direction of the Engineer-in-charge.

250

-

-

... More
Supplying of 12"x12" size of FRP square pot in White color with 12" ht. & as per direction of the Engineer-in-charge.

150

-

-

... More
Supplying of 14"x14" size of FRP square pot in White color with 24" ht. & as per direction of the Engineer-in-charge.

25

-

-

... More
Supplying of 12"x36" size of FRP rectangular pot in White color with 12" ht. & as per direction of the Engineer-in-charge.

50

-

-

... More
Supplying of 9"x30" size of FRP rectangular pot in White color with 9" ht. & as per direction of the Engineer-in-charge.

50

-

-

... More
Supplying of Plastic bottam drip tray 8"-10" dia for earthern pot & as per direction of the Engineer-in-charge.

500

-

-

... More
Supply of Cast Iron Bench for 3 adult person, as per approved sample.

15

-

-

... More
Supply and placing of Dholpur / Agra Stone Fountain, as per approved sample.

3

-

-

... More
Supply and placing of Dholpur / Agra Stone Statues/ Garden Ornamentals approx. 3-4 ft ht, as per approved sample.

10

-

-

... More
Suppling and Fixing of bio wall panel (Vertical Garden) with three pots, made of plastic in black color, R.S. Enterprises make. Fixing with Bio wall Alumunium frame will be anchored /welded with supported wall , Or drilling & fasteners and Bio wall panel will be screwed with suitable nut and bolts.Plantation of Supply and installaion of out door and indoor plants with dwarf & spreading habit. Soilless media:- in Mix format is used as planting Tech. Mix -Soil and Manure etc. and placed in the PP Pot." Installation of Irrigation systems should be with online screen filter, Control ball valves, pvc pipeline up to drip irrigation system for each plant, connections from PVC pipe,16 mm LLDPE lateral pipe, connecters & 2 – 4 lph dripper nozzles (one nozzle per planter). Supply of pump and installation is additional cost. Overhead tank pressure is suffuicient we need 1- 2 kg pressure for run the drip irrigation system & as per direction of Engineer-in-charge.

50

-

-

... More
PART-Q : AREA DEVELOPMENT

-

-

-

... More
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth lead upto 1 Km and all lifts, as directed by Engineer-in-Charge: All kinds of soil

6000

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth, lead upto 1 Km and all lifts, disposed earth to be levelled and neatly dressed all as per drawing or direction by Engineer - in - Charge a) All kinds of soil at all depth

6219

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 100 m and all lifts, disposed earth to be levelled and neatly dressed a) Hard rock (blasting prohibited)

2128

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil at all depth

500

-

-

... More
Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 1Km and all lifts : All Kind of Soil

21473

-

-

... More
Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth.

21473

-

-

... More
PART-R : PLAY FIELDS EQUIPMENTS & PLAY FIELD WORKS

-

-

-

... More
Small Children Playground Equipment.

-

-

-

... More
Providing and fixing Dome Climber (Code NES4319 ) of NES or equivailent make of Area dia 10 ft. Main Frame pipe 27MM OD MS pipe with plate 6 inch dia Excluding execavation of 0.45 x 0.45 x 0.45 m size pie and fixing the each supporting leg / anchoring arm of playing instrument in 1:1½:3 grade concrete block of 0.45x0.45x0.45m size including curing etc. complete which will be paid separetely. Capacity : 10.-20 Children, age group : 5-10 years.

2

-

-

... More
Providing and fixing Snowden Climber (Code NES4354 ) of NES or equivailent make of Area dia 8 x 8x 5 ft Main Frame pipe 34, 27MM OD MS pipe with rungs 27mm OD MS pipe Excluding execavation of 0.45 x 0.45 x 0.45 m size pie and fixing the each supporting leg / anchoring arm of playing instrument in 1:1½:3 grade concrete block of 0.45x0.45x0.45m size including curing etc. complete which will be paid separetely. Capacity : 5-10 Children

2

-

-

... More
Providing and fixing Sea Saw Double (Code NES4405) of NES or equivailent make of Area dia 6.5 x 6 x 2.5 ft Main Frame60MM OD MS pipe with plank 48mm OD MS pipe, support 27mm OD MS piep, sheet FRP, Bearing bush Oiling type Excluding execavation of 0.45 x 0.45 x 0.45 m size pie and fixing the each supporting leg / anchoring arm of playing instrument in 1:1½:3 grade concrete block of 0.45x0.45x0.45m size including curing etc. complete which will be paid separetely. Capacity : 4 Children

5

-

-

... More
Providing and fixing Sea Saw Four Seater (Code NES4441) of NES or equivailent make of Area dia 5.5 x 6 x 1.5 ft Main Frame 90MM OD MS pipe with plank 75mm OD MS pipe, handle 27mm OD MS piep, sheet FRP, Bearing bush Oiling type Excluding execavation of 0.45 x 0.45 x 0.45 m size pie and fixing the each supporting leg / anchoring arm of playing instrument in 1:1½:3 grade concrete block of 0.45x0.45x0.45m size including curing etc. complete which will be paid separetely. Capacity : 2 Children

5

-

-

... More
Providing and fixing Doble Swing (Code NES4102) of NES or equivailent make of Area dia 10 x 6 x 8 ft Side Frame 60MM OD MS pipe, top frame 60mm OD pipe, rubber coated chain 6mm, Rubber seate with SS Ring, Cup bearing Excluding execavation of 0.45 x 0.45 x 0.45 m size pie and fixing the each supporting leg / anchoring arm of playing instrument in 1:1½:3 grade concrete block of 0.45x0.45x0.45m size including curing etc. complete which will be paid separetely. Capacity : 2 Children, Age group : 4-12 years.

2

-

-

... More
Providing and fixing Doble Swing -Eco (Code NES4102) of NES or equivailent make of Area dia 8 x 5 x 6.5 ft Side Frame 60MM OD MS pipe, top frame 60mm OD pipe, rubber coated chain 6mm, Rubber seate with SS Ring, Cup bearing Excluding execavation of 0.45 x 0.45 x 0.45 m size pie and fixing the each supporting leg / anchoring arm of playing instrument in 1:1½:3 grade concrete block of 0.45x0.45x0.45m size including curing etc. complete which will be paid separetely. Capacity : 2 Children, Age group : 4-12 years.

2

-

-

... More
Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. a) All kinds of soil

68

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).

7

-

-

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (For Play Equipments)

10

-

-

... More
OUT DOOR EQUIPMENT.

-

-

-

... More
Garden Benches Garden Bench Seat & back in wooden,side made of cast iron.5' length of bench Floor to seat height - 16".

100

-

-

... More
Garden Bench MFGB-814 Seat & back in ms, side made of cast iron.5' length of bench Floor to seat height - 16" weight approx 70-75 kg.

75

-

-

... More
HDP DUSTBINS-CAP.120 LTR.

75

-

-

... More
Football Court (100m x 55 m)=5500Sqmt=59200 Sqft BASE: Excavation, compaction and achieving 1% slope and clearance of waste material, Supply and Installation of perforated 4'' Dia PVC pipe system at the interval of every 5 m. Followed by construction of the Layered Gravel/Stone base not less than 100 mm thick using varied size of jelly stone, finishing with compaction at each layer of stones. Drainage: Providing and Constructing of 200mm in depth and 150 mm in width using 6" wide solid block masonry finished using 12mm cement Plaster. Toe Wall: Supply and construction of 6" wide solid block masonry 6" below the ground and 6" above the surface & 12mm cement Plaster. Accessories: Supply & installation of Steel Field Goal Posts.(set) Size (8 Ft X 12 Ft). Turf: Supply of FIFA Quality Pro 60mm Artificial Turf. Sand Infill: As per FIFA Standard. Rubber Infill: As per FIFA Standard. Installation of Turf: As per FIFA Standard. Lighting: Supply and installation of Metal Halide Lights with all accessories, wires and MCB on each Pole of 17 feet height. Fencing: Supply and Installation of nylon fencing of 4mm dia & 50x50mm mesh size of height 17 feet,poles placed 20ft c/c. Total height of fencing 17 feet.

5502

-

-

... More
Tennis Court(35m x 17 m)=595Sqmt=6405 Sqft SYNTHETIC WORK:- Providing and Laying of ITF Classified 8 Layers “PACE COURT” Synthetic Acrylic Color Coating for Outdoor Tennis Court. (4 Nos.)  One Layer of “PACE COURT” Concrete Primer.  One Layer of “PACE COURT” Acrylic Resurfacer.  Four Layers of “PACE COURT” Cushion Coat  Two Layers of “PACE COURT” Acrylic Color Coating  White Line Marking

596

-

-

... More
Valley Ball Court(18m x 9 m)=162Sqmt=1745 Sqft SYNTHETIC WORK:- Providing and Laying of ITF Classified 8 Layers “PACE COURT” Synthetic Acrylic Color Coating for Outdoor Volleyball Court.  One Layer of “PACE COURT” Concrete Primer.  One Layer of “PACE COURT” Acrylic Resurfacer.  Four Layers of “PACE COURT” Cushion Coat  Two Layers of “PACE COURT” Acrylic Color Coating  White Line Marking

163

-

-

... More
Basket Ball Court (28m x15 m)=420Sqmt=4520 Sqft SYNTHETIC WORK:- Providing and Laying of ITF Classified 8 Layers “PACE COURT” Synthetic Acrylic Color Coating for Outdoor Basketball Court. (2 Nos.)  One Layer of “PACE COURT” Concrete Primer.  One Layer of “PACE COURT” Acrylic Resurfacer.  Four Layers of “PACE COURT” Cushion Coat  Two Layers of “PACE COURT” Acrylic Color Coating  White Line Marking

421

-

-

... More
PART-S : FURNITURE WORKS

-

-

-

... More
Supply of Standard steel Almirah Medium of Size 1266 x750x 430mm with 2 Nos shelves making 3 compartment.body and shelves fabricated from 22 gauge thick CRC MS plane sheet & doors with 20 gauge thick CRC MS plane sheet. Shutters shall be 02 Nos. with locking arrangments of approved make Godrej/ Harrison including duplicate key. Handle should be 100mm long chromium plated steel. All surface of Almirah shall be Powder Coated of approved colours/shades all as per Engineer-in-Charge.

681

-

-

... More
Supply of Standard steel Almirah Large (Domistic Type with Locker safe) of Size 1980 x 1050x 560 mm domestic type (Half hanging)body fabricated from 20 gauge thick CRC MS plane sheet on top, bottom & doors and 22 gauge thick CRC MS plane sheet on sides, back & shelves. SS Hanging rod shall be 19/20mm dia, steel chromium plated condute pipe of wall thickness 1.25 mm with standard steel chromium plated socket at each end. Shutters shall be 02 Nos. with locking arrangments of approved make Godrej/ Harrison including duplicate key. Door Handle should be 100mm long steel chromium plated. Almirah shall be provided with one locker with locking arrangments of approved make. All serface (inside& outside) of Almirah shall be Powder Coated of approved colours/shades all as per Engineer-in-Charge.

109

-

-

... More
Supply of Standard steel Almirah Large of size 1980x910x480 mm with 4 Nos shelves making 5 compartment.body and shelves fabricated from 22 gauge thick CRC MS plane sheet & doors with 20 gauge thick CRC MS plane sheet. Shutters shall be 02 Nos. with locking arrangments of approved make Godrej/ Harrison including duplicate key. Handle should be 100mm long chromium plated steel. All surface of Almirah shall be Powder Coated of approved colours/shades all as per Engineer-in-Charge.

10

-

-

... More
Provision of wooden wardrobe 600 mm deep made out of 19 mm thick commercial board covered having vertical and horizental shelf, 6 mm commercial ply on back having hanging road of dia 20mm fitted with bracket. Shutter to have 19 mm thick commercial board finished with 1mm thick approved quality of laminate. All exposed edges to have teak wood lipping including necessary hardware like hinges, tower bolt, handels & lock all as per approved sample. All internal area finished with 0.8mm laminate. All internal surface area to be finished with sprite polish etc. all complete.

15

-

-

... More
Provision of wooden wardrobe 600 mm deep made out of 19 mm thick commercial board,having vertical and horizental shelf, 6 mm commercial ply on back having hanging road of dia 20mm fitted with bracket. Shutter to have 19 mm thick commercial board finished with 1mm thick approved quality of laminate. All exposed edges to have teak wood lipping including necessary hardware like hinges, tower bolt, handels & lock all as per approved sample. All internal surface area to be finished with sprite polish etc. all complete.

8

-

-

... More
Supply of Almirah wooden medium of Size 1200 x 900 x 450mm made out of 19mm thick commercial board with 3 Nos. shelves all edges to be covered with teak wood lipping. sides, shutters and top to have 1mm thick laminate with locking arrangements of approved make Godrej/ Harrison including duplicate key. All internal surface area to be finished with sprite polish etc all complete as per Engineer-in-Charge.

2

-

-

... More
Supply of Cupboard wooden large of Size 1980 x 1050x 560mm made out of 19mm thick commercial board with 3 Nos. shelves all edges to be covered with teak wood lipping. sides, shutters and top to have 1mm thick laminate with locking arrangements of approved make Godrej/ Harrison including duplicate key. All internal surface area to be finished with sprite polish etc all complete as per Engineer-in-Charge.

1

-

-

... More
Supply of Steel Bed side Locker of size 1200 X 900 X 500 mm with two compartments having double door, made out of body fabricated from 20 gauge thick CRC MS plane sheet on top, bottom & doors and 22 gauge thick CRC MS plane sheet on sides, back & shelves,19mm dia hanging rod with bracket at top, locking arrangement with duplicate key of approved quality finished with Powder Coated all surface of approved shade/ colours etc all complete .

9

-

-

... More
Supply and fixing of wooden (Oak) wall bar having provision of 14 rungs, Wall Mount System – Includes all of the rungs needed along with (2) 90" Monster Lite Uprights and (4) Wall Mounting Brackets. The Stall Bars should only be mounted to a rig or rack that is securely fastened to the floor. Each Stall Bar unit stands 90" tall, and the rungs themselves are 43" wide and spaced 6” on center. The wood diameter shall be 1.5" etc all complete.

25

-

-

... More
Supply of key case for 50 Nos. (electronic) as per approved sample.

4

-

-

... More
Supply of Biliards Chair (High rise) clean lines are complemented by roomy faux black leather cushions. The wide chair arms include a drink holder and a cue rest. The drink holders are spill proof depth. Easy assembly, tools included. Overall Dimensions: 45" H x 30" W x 21" D ; Seat Height: 31" ; Total Height: 45" ; Foot Bar Height: 12" ; Foot Bar Width: 19" ; Foot Bar Depth: 3.5" ; Arm Height (top): 37" ; Outside Arm Width: 30" ; Inside Arm Width: 18" ; Cup Holder Depth: 2.5" ; Arm Width: 6" ; Foot Width: 20.5" ; Foot Depth: 19.5" ; Seat Depth: 19.5" ; Seat Width: 18" etc all complete as per approved sample.

4

-

-

... More
Supply of Hard Bed Single Wooden of size 1950 X 930 X 350 mm made out of teak wood with side rail of size 120 X 30 mm. Head board shell 930(width) X 800(ht) mm and foot board 930(width) X 400(ht) mm same shell be made out of 70 X 30 mm second class hard wood frame covered unit 4 mm thick one side teak ply and other side 4 mm thick commercial ply ,edges to have 40 X 9 mm thick teak wood curved moulding and 4 nos of 50 X 25 mm support of second class hard wood and 12 mm thick commercial ply on bed top all finished with melamine polish etc. all complete as per approved sample.

998

-

-

... More
Supply of box type Single Bed of size 2015 x 935 x 325 mm (Mattress Size 1900 x 900mm) Box made out of 19 mm thick commercial board covered with 2.5mm thick teak veneer, leg with teak wood, top with opnable 12 mm thick commercial ply provided with 1 Nos support with second class hardwood of size 70 x30mm, bottom with 6mm thicl ply over 3 nos of supports of second class hardwood of size 45 x30mm, edges covered with teak wood lipping. Head board shall be straight till 450mm hight and above 450mm it shoude be lenning backwards approximately 75mm, head board with hard wood frame behind 19mm thick commercial board and 2.5mm teak ply in decorative pattern on the front face and 6 mm thick commercial ply at the back, teak wood decorative moulding, finished with melamine polish etc. all complete as per approved sample.

104

-

-

... More
Supply of box type Single Bed of size 2015 x 1235 x 325 mm (Mattress Size 1900 x 1200mm) Box made out of 19 mm thick commercial board covered with 2.5mm thick teak veneer, leg with teak wood, top with opnable 12 mm thick commercial ply provided with pair of shocker, 1 Nos support with second class hardwood of size 70 x30mm, bottom with 6mm thicl ply over 3 nos of supports of second class hardwood of size 45 x30mm, edges covered with teak wood lipping. Head board shall be straight till 450mm hight and above 450mm it shoude be lenning backwards approximately 75mm, head board with hard wood frame behind 19mm thick commercial board and 6mm thick ply having 50mm thick foam upholestred with leathrite of approved shade in (Quilting work) decorative pattern on the front face and 6 mm thick commercial ply at the back, teak wood decorative moulding, finished with melamine polish etc. all complete as per approved sample.

10

-

-

... More
Supply of box type Double Bed of size 2015 x 1835 x 325 mm (Mattress Size 1900 x 1800mm) Box made out of 19 mm thick commercial board covered with 2.5mm thick teak veneer, leg with teak wood, top with opnable 12 mm thick commercial ply, 1 Nos support with second class hardwood of size 70 x30mm, bottom with 6mm thicl ply over 3 nos of supports of second class hardwood of size 45 x30mm, edges covered with teak wood lipping. each sides of bed having 3 nos of decorative panelling work with 12mm thick commercial ply with alround moulding Head board shall be straight till 450mm hight and above 450mm it shoude be lenning backwards approximately 75mm, head board (60% Soft quilting work & 40 % veneering) with hard wood frame behind 19mm thick commercial board and 6mm thick ply having 50mm thick foam upholestred with leathrite of approved shade in (Quilting work) decorative pattern on the front face and 6 mm thick commercial ply at the back, teak wood decorative moulding, finished with melamine polish etc. all complete as per approved sample.

208

-

-

... More
Supply of box type Double Bed of size 2015 x 1835 x 325 mm (Mattress Size 1900 x 1800mm) Box made out of 19 mm thick commercial board covered with 2.5mm thick teak veneer, leg with teak wood, top with opnable 12 mm thick commercial ply provided with pair of shocker, 1 Nos support with second class hardwood of size 70 x30mm, bottom with 6mm thicl ply over 3 nos of supports of second class hardwood of size 45 x30mm, edges covered with teak wood lipping. each sides of bed having 3 nos of decorative panelling work with 12mm thick commercial ply with alround moulding Head board shall be straight till 450mm hight and above 450mm it shoude be lenning backwards approximately 75mm, head board (60% Soft quilting work & 40 % veneering) with hard wood frame behind 19mm thick commercial board and 6mm thick ply having 50mm thick foam upholestred with leathrite of approved shade in (Quilting work) decorative pattern on the front face and 6 mm thick commercial ply at the back, teak wood decorative moulding, finished with melamine polish etc. all complete as per approved sample.

15

-

-

... More
Supply of box type Single Bed of size 1950 x 935 x 325 mm (Mattress Size 1900 x 900mm) Box made out of 19 mm thick commercial board covered with 1mm thick Laminate, leg with teak wood, top with opnable 12 mm thick commercial ply, 1 Nos support with second class hardwood of size 70 x30mm, bottom with 6mm thicl ply over 3 nos of supports of second class hardwood of size 45 x30mm, edges covered with teak wood lipping. Head board shall be straight till 450mm hight and above 450mm it shoude be lenning backwards approximately 75mm, head board with hard wood frame behind 19mm thick commercial board and 2.5mm teak ply in decorative pattern on the front face and 6 mm thick commercial ply at the back, teak wood decorative moulding, finished with melamine polish etc. all complete as per approved sample.

98

-

-

... More
Supply of box type Double Bed of size 2015 x 1835 x 325 mm (Mattress Size 1900 x 1800mm) Box made out of 19 mm thick commercial board covered with 2.5mm thick teak veneer, leg with teak wood, top with opnable 12 mm thick commercial ply, 1 Nos support with second class hardwood of size 70 x30mm, bottom with 6mm thicl ply over 3 nos of supports of second class hardwood of size 45 x30mm, edges covered with teak wood lipping. each sides of bed having 3 nos of decorative panelling work with 12mm thick commercial ply with alround moulding Head board shall be straight till 450mm hight and above 450mm it shoude be lenning backwards approximately 75mm, head board (60% Soft quilting work & 40 % veneering) with hard wood frame behind 19mm thick commercial board and 6mm thick ply having 50mm thick foam upholestred with leathrite of approved shade in (Quilting work) decorative pattern on the front face and 6 mm thick commercial ply at the back, teak wood decorative moulding, finished with melamine polish etc. all complete as per approved sample.

2

-

-

... More
Supply of standard steel four door Book Shelf of size 1680 x 840 x 300 mm body fabricated from 20 gauge thick CRC MS plane sheet on top, bottom & doors and 22 gauge thick CRC MS plane sheet on sides, back & shelves with 4 compartments each fitted with top hung disappearing glass door with individual locking arrangement of approved make & quality. All serface (inside& outside) of Book Shelf shall be powder coated of approved colours/shades all complete as per Engineer-in-Charge.

203

-

-

... More
Supply of Wooden book shelve of size 2100 X 900 X 400mm made out of 19 mm thick commercial board covered with 2.5 mm thick teak veneer on outer sides and all internal area to be finished with 0.8 mm Laminate, back with 6mm thick commercial ply. Making 5 compartments with 4 nos of shalves. Provided with Teak wood glazed shutters with 5 mm thick etched glass. Top to have 150mm skirting with two runs of teak wood moulding (one with 30X30 teak wood cornish and other with 15 X15mm) including all neccessery fittings all exposed edges to have teak wood li[pping finished with melamine polish.etc all complete as per Engineer-in-Charge.

11

-

-

... More
Supply of Writing Chair of size 450 x 450 x 900 mm made out of teak wood 45x30mm frame work without arm with 12 mm thick commercial ply with 50 mm thick high density foam on seat duly upholstered with fabric of approved shade and quality back having teak wood strip in approved pattern including melamine polish etc. all complete as per approved sample.

100

-

-

... More
Supply of Writing Chair of size 450 x 450 x 900 mm made out of teak wood 45x30mm frame work without arm with 12 mm thick commercial ply with 50 mm thick high density foam on seat duly upholstered with fabric of approved shade and quality back having teak wood strip in approved pattern including melamine polish etc. all complete as per approved sample.

104

-

-

... More
Supply of standard cushioned PVC moulded Verandah chair with arms of make Neelkamal model CHR 2180 or / Supreme / Cello as per approved sample.

198

-

-

... More
Supply of Bath Stool of PVC good quality & standard make Nayasa, Cello and Supreme and as per approved sample.

230

-

-

... More
Supply of bin linen multipurpose of Dimension 440 x 327 x 570mm model LUNDRY BASKET on Nilkamal Make or Nayasa, Cello and Supreme and as per approved sample.Material:Plastic

116

-

-

... More
Supply of PVC Receptacle universal with bucket of capacity 10 Ltrs with lid and provided with removiable basket of good quality and approved make cello or equivalent and as per approved sample.

115

-

-

... More
Supply of PVC Receptacle universal with bucket of capacity 20 Ltrs with lid and provided with removiable basket of good quality and approved make cello or equivalent and as per approved sample.

10

-

-

... More
Supply of SS Receptacle universal with bucket of capacity 10 Ltrs with lid and provided with removiable basket of good quality and approved make and as per approved sample.

18

-

-

... More
Supply of PVC Receptacle of capacity 5 Ltrs of approved quality make cello or equivalent.

5

-

-

... More
Supply of Folding charpoy of size 1875x900x450mm frame made out of 32mm dia MS pipe of 18 gauge having Necessary MS strip etc. Legs of charpoy to be provided with rabber shoe, duly powder coated, top with 12mm thick commercial ply finished with spirit polish etc. all complete as per approved sample.

207

-

-

... More
Supply of chorpoy (Hard top) of Size 1950 x 900 x 425mm made out of GI pipe 32 mm dia of medium grade provided with 4 nos three way elbow and Chucknut at one side, top to have12mm thick commercial ply finished with sprite polish having two nos supports duly painted made out of 18 x18mm of 18 guage MS CRC tubler pipe at equal distance, legs of chorpoy to be provided with rubber shoe and provision of holding MNF set. MNF set shall be provided using 15 mm dia MS CRC round tube duly enamal painted etc all complete as per approved sample.

123

-

-

... More
Supply of high back Dining Chair of size 450 x 450 x 900 mm made out of teak wood 45X30mm frame work with tapered 45 X 45 mm teak wood front legs,without arm with 12 mm thick commercial ply with 50 mm thick high density foam on seat duly upholstered with fabric of approved shade and quality back having teak wood strip in approved pattern including Sprite polish etc. all complete as per approved sample.

2252

-

-

... More
Supply of high back Dining Chair of size 450 x 450 x 900 mm made out of teak wood 45X30mm frame work with orintal 65 X65 mm teak wood front legs, back to be provided with good back curve of atlest 50mm. without arm with 12 mm thick commercial ply with 50 mm thick high density foam on seat duly upholstered with fabric of approved shade and quality back having teak wood strips in decorative approved pattern including melamine polish etc. all complete as per approved sample.

624

-

-

... More
Supply of Executive high back Dining Chair of size 450 x 450 x 900 mm made out of teak wood 45X30mm frame work with orintal 65 X65 mm teak wood front legs, back to be provided with good back curve of atlest 50mm. without arm with 12 mm thick commercial ply with 50 mm thick high density foam on seat and back having 25mm thick HD foam duly upholstered with fabric of approved shade and quality in approved pattern including melamine polish etc. all complete as per approved sample.

100

-

-

... More
Supply of Table for 8 Persons of size 2400 X 1050 X 750 mm made out of teak wood frame (side rail 120 X 30 mm & orintal legs 90x90mm with light carving work on all parts) top with19mm commercial board covered with 16mm thick italian marble having polished double edge & taper moulding. all exposed edges to have lipping finished with melamine polish etc. all complete as per approved sample.

2

-

-

... More
Supply of Executive Writing Chair of size 450 x 450 x 900 mm made out of teak wood 45X30mm frame work with orintal 65 X65 mm teak wood front legs, back to be provided with good back curve of atlest 50mm. without arm with 12 mm thick commercial ply with 50 mm thick high density foam on seat duly upholstered with fabric of approved shade and quality back having teak wood strips in decorative approved pattern including melamine polish etc. all complete as per approved sample.

11

-

-

... More
Supply of Executives writing table of size 1200 x 600 x 750 mm made out of teak wood orintal legs 60x60mm,sides and back with 19mm thick commercial board with 2.5mm thick teak veneer & front with teak wood of size 90x30mm, top with 19mm thick commercial board with 2.5mm thick thick teak veneer, top to have addition moulding alround of 30x30mm, 2 nos of bottom side rails and 1 no bottom long rail with teak wood ( Sectional size 45x 30mm) provided with 2Nos of drawers (Drawer head to have panel work with 12mm thick commercial ply with corner beading), & 1 no. Keyboard tray ride on telescopic channels with handle of approved make & design. all exposed edges to have half round teak wood beading finished with melamine polish all inner portion of drawers finished with 0.8mm thick laminate etc. all complete as per approved sample.

11

-

-

... More
Supply of Executive high back Dining Chair of size 450 x 450 x 900 mm made out of teak wood 45X30mm frame work with orintal 65 X65 mm teak wood front legs, back to be provided with good back curve of atlest 50mm. without arm with 12 mm thick commercial ply with 50 mm thick high density foam on seat and back having 25mm thick HD foam duly upholstered with fabric of approved shade and quality in approved pattern including melamine polish etc. all complete as per approved sample.

40

-

-

... More
Supply of Executive Revolving and Tilting high back chair of size 560 X 590 X 1100 mm, having seat and back made of moulded PU foam 50 mm thick and black copolymer on outer cover. The arm rest shall be made of steel inserted black polyproplene for superior comfert, chest shall have gas lift mechanism and shall be supported on steel inserted nylon base with 5 castors pedestal of approved quality .The frame shall be upholstered with leatherete of approved quality and colour all complete as per direction of Engineer-in- Charge.

9

-

-

... More
Supply of Computer Chair of Size 510 x 410 x 800 mm high Without armsmoulded 12 mm hot pressed ply with 50 mm thick cushion seat & back, upholstered with approved quality of fabric, mounted on powder coated five twin castors, hydraulic gas lift pedestal etc. all complete as per approved sample.

551

-

-

... More
Supply of Computer Chair of overall Size H 37 x W 22 x D 24; Seating Height - 19 (all dimensions in inches) having made from fibre frame, Fabric seat and mesh back, Fixed polypropylene handles, Ergonomic design, Hydraulic gaslift Adjustable height range: 4 Inches Reclining 40 Degrees , Five prong legs with 5 nylon castors for easy mobility, base finished with black powder coated etc. all complete as per approved sample.

10

-

-

... More
Supply of revolving Low back Revolving chair of size 425 X 460 X 800 mm high having moulded 12 mm hot pressed ply with 50 mm thick high density foam on seat and back covered with approved quality of fabric along with PU full arms, mounted on five castors pedestal all complete as per approved sample.

2

-

-

... More
Supply of revolving Low back Revolving chair of size 525 X 525 X 800 mm high having moulded 12 mm hot pressed ply with 50 mm thick high density foam on seat and back covered with approved quality of fabric along with PU full arms, mounted on five castors pedestal all complete.

14

-

-

... More
Supply of Visitor Revolving Chair of size 515 x 515 x 800 mm high having moulded 12 mm hot pressed ply with 60mm high density PU seat & back duly covered with approved quality of fabric along with PU full arms mounted on powder coated five castors pedestal all as per sample.

34

-

-

... More
Supply of Revolving and Tilting Executive Computer Back Chair of size 515 X 515 X 800 mm high having moulded 12 mm hot pressed ply with 50 mm thick high density PU seat and back covered with fully upholsted with leatherete of approved shade/ colour along with rubberized PU arms rest mounted on five castors pedestal wheel with gas lift mechanism all complete as per approved sample.

104

-

-

... More
Supply of Revolving and Tilting Executive Medium Back Chair of size 515 X 515 X 800 mm high having moulded 12 mm hot pressed ply with 60 mm thick high density PU seat and back fixed on 15 mm dia steel tubler frame covered with 35 mm thick foam on both the side fully upholsted with leatherete of approved shade/ colour along with rubberized PU arms rest mounted on five castors pedestal wheel with gas lift mechanism all complete as per approved sample.

6

-

-

... More
Supply of standard cushioned PVC moulded chair with arms of make Neelkamal model Club Chair of Novella Series or / Supreme / Cello as per approved sample.

20

-

-

... More
Supply of standard cushioned PVC moulded Verandah chair with arms of make Neelkamal model Novella 10 or / Supreme / Cello as per approved sample.

442

-

-

... More
Supply of standard PVC moulded Verandah chair with arms of make Neelkamal / Supreme / Cello as per approved sample.

4

-

-

... More
Supply of standard cushioned PVC moulded Verandah chair with arms, coushioned seat and back of make Supreme model Ornate Black/Red or / Nilkamal / Cello as per approved sample.

1854

-

-

... More
Supply of Study Chair steel of size 450x500x900mm with writing pad of size 500 x 300 x 25mm made out of prelaminated Partical board & edge binding with 2 mm thick pvc edgebinding tape. chair structure made with 25mm dia 16 guage MS pipe, 50mm thick moulded cushioned on seat and back over 12mm thick moulded ply. duly covered with fabric upholstery, metaled powder coated under structure, with arm rest and rotateble in & out writing pad. provided with basket of keeping documents all complete as per approved sample.

450

-

-

... More
Supply of Easy Chairs of size 500x475x800mm structure made out of second class headr wood frame work (sectional size 45 x30mm, front and back legs made out of teak wood of size 40x40mm. on arms and curved back duly upholstered with 25mm thick high density rubber foam & fabric. Seat to have 75mm thick HD foam fixed over cross mesh of 50mm elastic niwar duly covered with fabric of approved quality. all exposed wooden to be finished with melamine polish etc. all complete as per approved sample.

30

-

-

... More
Supply of Coffe Chairs of size 500x475x800mm structure made out of second class headr wood frame work (sectional size 45 x30mm, front and back legs made out of teak wood of size 40x40mm. Arms and curved back duly upholstered with 25mm thick high density rubber foam & fabric. Seat to have 75mm thick HD foam fixed over cross mesh of 50mm elastic niwar duly covered with fabric of approved quality. all exposed wooden to be finished with melamine polish etc. all complete as per approved sample.

30

-

-

... More
Supply of Hat Stand with mirror of size 900x600mm made out of 19mm thick commercial block board with 4mm thick veneer having 25x6mm thick teak wood beading around the board with 450x300mm mirror fixed on right/left hand side as required having 4 Nos. CP hook including melamine polishing on all exposed wooden surfaces etc. all complete as per approved sample.

111

-

-

... More
Supply of Hat Stand with mirror of 300mm deep made out of 19mm thick commercial block board with 4mm thick veneer having 25x6mm thick teak wood beading around the board with 5mm looking mirror of approved size fixed as required having 24 Nos. CP hook (in 4 SM). Center portion to have 2 nos of shelves, including paneling work of teak wood moulding and decorative taj, all finished with melamine polishing on all exposed wooden surfaces etc. all complete as per approved sample.

13

-

-

... More
Supply of Wooden console with Ornamental Mirror frame.Console of size 1200x375x750mm made out of teak wood frame ( side rail 90x25mm, orintal legs 90x90mm with heavy carving work on all parts) top with 19mm thick commercial board covered with 2.5 mm thick teak veneer, having 30 x30mm teak wood moulding around top Ornamental wooden Mirror frame made out of teakwood (sides 75 x 35mm & top 120 x 38mm) havind heavy carving work provided with 5mm thick looking mirror. all wooden area finished with melamine polish etc. all complete as per approved sample.

1

-

-

... More
Supply of Dressing stool of size 375x375x435mm made out of 12mm thick commercial ply, all sides with 1mm thick laminate .Top to have 12mm thick commercial ply with 50mm high density foam duly upholstered with approved fabric. Provided with 4Nos castors finished with melamine polish etc. all complete as per approved sample.

202

-

-

... More
Supply of Dressing stool of size 400x400x400mm made out of teak wood frame ( side rail 70x25mm & orintal legs 45x45mm with light carving work) top with 12mm thick commercial ply with 50mm thick 32 density foam covered with fabric of approved fabric, all wooden area finished with melamine polish etc. all complete as per approved sample.

16

-

-

... More
Supply of adjustable stool having Overall height of the stool: LxBxH: 427x427x1220. 202 SWG SS frame work 3 inch dia. main tube with circular base including foot rest, seat with 12 mm commercial ply with 50 mm cushion with good quality having back rest and approved sample etc. all complete as per approved sample.

18

-

-

... More
Supply of sofa (2+1+1) as per approved design, configuration made out of hard wood frame work, seat and back with 2nd class hard wood , seat cushioned with 75mm thick high density foam and extra padding with 20mm thick foam for making shape on seat & back. Back with 50 mm thick high density foam duly upholstered with fabric of approved shade & quality (cost of fabric not to be exceed Rs.400/meter) minimum 125mm wide teak wood to be fixed on area all exposed wooden surface finished with Sprit polish etc. all complete of the following size and as per approved sample. :-

-

-

-

... More
Sofa Single Seater (outer size 710W x 600D x 800H)

196

-

-

... More
Sofa Two Seater (outer size 1260W x 600D x 800H)

98

-

-

... More
Supply of superior quality sofa (3+1+1) as per approved design, configuration made out of hard wood frame work, seat and back with 2nd class hard wood , seat cushioned with 75mm thick high density foam and extra padding with 20mm thick foam for making shape on seat & back. Back with 50 mm thick high density foam duly upholstered with fabric of approved shade & quality (cost of fabric not to be exceed Rs.400/meter) minimum 125mm wide teak wood to be fixed on area all exposed wooden surface finished with melamine polish etc. all complete of the following size and as per approved sample. :-

-

-

-

... More
Sofa Single Seater (outer size 810W x 700D x 800H)

248

-

-

... More
Sofa Three Seater (outer size 1900W x 700D x 800H)

123

-

-

... More
Supply of contempenecy design sofa set (3+1+1) under structure is made out of hard wood (45x30mm) frame work seat & back to have cross webbed stretchable nylon newer over spongy platefoam made out of spiral / zigzag steel spring all under 100 mm thick in seat & 50 mm in back 40 density HD foam with another layer of 25mm thick HD foam for fine shaping etc & final layer of polyfill synthetic cotton. Arms to have out curved shape covered with 25mm thick hd foam, skirting made with 90x30mm teakwood having light carving work, on primea face of arms finished with 150mm wide teakwood with light carving work in matching shape of arms. Legs with teakwood in decorative pattern. final finishing & perfences all covered(except teakwood surface) with fabric of approve quality shade. all teak wood surface area finished with with melamine polish including loose cousin of approved size etc all complete

-

-

-

... More
Sofa Single Seater (outer size 1000W x 750D x 800H)

20

-

-

... More
Sofa Three Seater (outer size 2050W x 750D x 800H)

10

-

-

... More
Supply of Ordinary sofa set as per approved design, configuration made out of 45x30mm 2nd class hard wood frame, seat cushioned with 75mm thick high density foam and extra padding with 20mm thick foam for making shape on seat & back. Back with 50 mm thick high density foam duly upholstered with fabric of approved shade & quality (cost of fabric not to be exceed Rs. 275/ per meter) minimum 90 mm wide teak wood to be fixed on arms all exposed wooden surface finished with melamine polish etc. all complete of the following size and as per approved sample. :- a) Sofa Three Seater

4

-

-

... More
Supply of superior quality sofa Single seater as per approved design, configuration made out of teak wood frame work, seat and back with 2nd class hard wood, seat cushioned with 75mm thick high density foam and extra padding with 20mm thick foam for making shape on seat & back. Back with 50 mm thick high density foam duly upholstered with fabric of approved shade & quality (cost of fabric not to be exceed Rs.450/meter) minimum 125mm wide teak wood to be fixed on area all exposed wooden surface finished with melamine polish etc. all complete of the following size and as per approved sample. :-

10

-

-

... More
SEAT REST ASSEMBLY: The seat rest assembly is made up of 1.2+0.1 cm thk. flat plywood measured as per QA method described in OCP-QLTA-P14-18 with moulded polyurethane foam & upholstered with 3 layered foam laminated fabric.The seat profile is developed to help the users to get necessary comfort in popliteal region and ease of use in forward push for the seat sliding feature. SEAT SIZE: 45.0 CM. (W) x 44.5 cm.(D) X12.0 CM.(T) @ Front edge and 8.0 cm @ Rear edge. BACKREST ASSEMBLY: The backrest assembly is made up of a M.S. Fabricated frame in-situ moulded with polyurethane foam. The back foam is designed with contoured lumbar support for extra comfort @ upright and tilted conditions. The back frame is having nylon reinforced elastic bands to retain the profile and give a better cushioning feel *BACK SIZE: 46.5 CM.(W) X 62.5 CM.(H) X 9.0 CM. (T) avg. HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam for seat & back is moulded with density = 48+/-2 kg/m3 and hardness load 16+2 kgf as per IS: 7888 for 25% compression. ARMEST: The armrest is made up of integral Polyurethane Foam with 65+/-10 Shore Hardness and reinforced with M.S. insert. The armrest is available in two options with and without cup holder.

-

-

-

... More
SLIDING MECHANISM: The sliding mechanism is fabricated from M.S sheets forming linkages providing a 4-bar synchronous motion for the seat & back. The sliding stroke for the seat is 10.0+0.5 cm. the mechanism houses the seat & back and has a special feature of upright resistance lock to avoid activation of sliding feature unless enough force is applied by user when tilting is required. The Roller is made up of Nylon for ease of movement in seat. SIDE PANEL/ AISLE PANEL: The chair rests on the ground on two side panels frames made of 0.25+0.020 thk CR steel. Each side panel is clad with two fabric upholstered particle board of 0.9 cm thk. The side panel frame is grouted to the floor using 2 nos. anchors for each panel through the 0.5+0.05 cm. thk HR steel base plate. POWDER COATING: All steel components are epoxy polyester powder coated (DFT 40-60 microns). UPHOLSTERY FABRIC:The 3 layered foam laminated fabric is available in two shades- Ruby Red and Azure Blue- so as tocreate desired patterns in the layout. FLOORING PRE-REQUISITE: The auditorium chair is designed to get mounted/grouted on floors with flooring specification as mentioned in flooring pre-requisite Godrej doc-no:STG 129368

-

-

-

... More
a) Supply of VIP Chair (Sofa Type, reclinning front row)

25

-

-

... More
b) Supply of chair executive cushion reclining

25

-

-

... More
c) Supply of Chair cushion reclining

450

-

-

... More
Supply of SS Que Manager as per approved sample.

30

-

-

... More
Supply of Brass Que Manager as per approved sample.

10

-

-

... More
Supply of double top type Podium of Size 610x600x1050 mm high made out of 19mm thick commercial board with 2.5mm thick teak ply on side & front having tapered top with 1mm thick laminate finished and one no of halfe top, top to have space for tube fittings and 1 no of drawer rid on telescopic channel, bottom portion to have pedestal of 75mm high, all three sides leaning out approximatly 75mm. front side having grove designe, inlcuding melamine polish etc.Front with SFC logo made out of 1mm thick SS sheet of perportional size all complete as per approved sample.

2

-

-

... More
Supply of desk table (3 seater with SFC logo) of size 2250 X 600 X 750 mm made out of 19 mm thick commercial board on sides and top all external sides are covered with 4mm thick teak veneer of approved quality. All exposed edges to have teak wood beading all exposed faces to be finished with melamine polish and other wooden face to be finished with melamine polish etc all complete as per approved sample.

3

-

-

... More
Supply and fixing of Book case cum cabinet 450 mm deep upto height of 750 mm and 300 mm for remaining height, made out of 19 mm thick commercial board top portion to have glazed shutter with 2.5 mm thick plain glass and 19 mm thick commercial block board shelf and bottom to have 19 mm thick commercial board shutter finished with 2.5 mm teak veneer all exposed edges to have teak wood beading duly polished including locking arrangement with duplicate key, handles and catches of approved make & design etc all complete.

10

-

-

... More
Supply of Center table of size 1050x525x450mm made out of teak wood frame ( side rail 70x25mm & legs 45x45mm) top with 19mm thick commercial board and 1mm thick laminate, all exposed edges to have half round beading finished with Sprit polish etc. all complete as per approved sample.

98

-

-

... More
Supply of Peg table of size 450x450x450mm made out of teak wood frame ( side rail 70x25mm, glass top frame 70x25mm & orintal legs 45x45mm) top with 12mm thick tempered, baveled, & edge polished plain glass all wooden area finished with melamine polish etc. all complete as per approved sample.

418

-

-

... More
Supply of Peg table of size 525x525x450mm made out of teak wood frame ( side rail 70x25mm, glass top frame 70x25mm & orintal legs 60x60mm with light carving work on all parts) top with 12mm thick tempered, baveled, & edge polished plain glass all wooden area finished with melamine polish etc. all complete as per approved sample.

44

-

-

... More
Supply of two tier center table of size 1200x600x450mm made out of teak wood frame ( side rail 70x25mm, glass top frame 70x25mm & orintal legs 60x60mm with light carving work on all parts) top with 12mm thick tempered, baveled, & edge polished plain glass bottom shelfe made out of 19mmthick commercial board covered with 2.5mm thick teak veneer all wooden area finished with melamine polish etc. all complete as per approved sample.

18

-

-

... More
Supply of Corner Table of size 600 X 600 X 400 mm made out of teak wood frame (side rail 70 X 25 mm & legs 45 X 45 mm) top with 19 mm commercial board and 1 mm thick laminate all exposed edges to have lipping finished with spirit polish etc. all complete as per approved sample.

1

-

-

... More
Supply of Centre Table two tier with glass top of size 1200x600x450 mm made out of teak wood frame 70x25 mm, glass top frame 70x25mm and 45x45 mm thick teak wood decorative legs, having 19mm thick plywood with laminated at bottom etc. including 20x20 mm teak wood molding all exposed surface to have beading finished with melamine polish etc. all complete as per approved sample.

112

-

-

... More
Supply of Center table of size 1200x600x450mm made out of teak wood frame ( side rail 70x25mm, glass top frame 70x25mm & orintal legs 60x60mm with light carving work on all parts) top with 12mm thick tempered, baveled, & edge polished plain glass all wooden area finished with melamine polish etc. all complete as per approved sample.

10

-

-

... More
Supply of Corner table of size 600x600x450mm made out of teak wood frame ( side rail 70x25mm, glass top frame 70x25mm & orintal legs 60x60mm with light carving work on all parts) top with 12mm thick tempered, baveled, & edge polished plain glass all wooden area finished with melamine polish etc. all complete as per approved sample.

32

-

-

... More
Supply of Table wooden of size 400x400x750mm made out of teak wood frame (side rail 70x25mm & legs 38x38mm) top with 19mm thick commercial board and 1mm thick laminate all exposed edges to have 20 x 20mm thick teak wood Cornish finished with melamine polish etc. all complete as per approved sample.

6

-

-

... More
Supply of Display Board of size 1200x600 mm made of teak wood frame of size 40x20 mm having pin up board covered with fabric including melamine polish to wooden frame etc. all complete.

2

-

-

... More
Supply of Notice Board of size 900 X 600 X 100 mm made out of 19 mm thick one side teak face block board having teak-wood frame shutter with 4 mm thick glass, and blazer cloth on background,all exposed edges to have teak wood beading including necessary hardware fittings and finished with spirit polish etc. all complete.

18

-

-

... More
Supply of signage with SS Stand, fixed with Red/Blue velvet on board of 600x1200mm as per approved sample.

2

-

-

... More
Supply of Wooden Table of size 900 X 900 X 750 mm made out of teak wood frame ( side rail 90x30mm & legs 70x70mm), with granite top of approved shade. All exposed edges to have lipping finished with melamine polish etc. all complete as per approved sample.

3

-

-

... More
Supply of ladies dressing table of size 750W X 400D X 1950H mm made out of 19mm thick commercial board, top. side & front covered with 1mm thick laminate. below 600mm hight making provision at one side for keeping dressing stool and other side one shutter and one drawer rid on telescopic channels. Above hight of 600mm making 300mm deep storage with 4 nos of 19mm thick shelves including 19mm thick commercial board shutter having 5mm thick looking mirror (Shutter size 500 x 1200mm & 300 x 1200mm with open shelves). top to have half round teak wood beading, including all neccessery hardware and fitting like catcher, hinges, & handles of approved make & design, all edges to have teak wood lipping finished with melamine polish etc. all complete as per approved sample.

98

-

-

... More
Supply of wall mounted Dressing Mirror with hanging arrangement made out of teak wood frame of size1200x450mm, having 5 mm looking mirror with 6 mm ply on back with dressing box of size 600x375x200 mm made out 19 mm commercial block board having 1mm thick laminate on sides and top provided with 1 nos of drawer rid on telescopic channel including Sprit polishing all complete as per approved sample.

3

-

-

... More
Supply of ladies dressing table of size 900W X 400D X 1950H mm made out of 19mm thick commercial board, top. side & front covered with 2.5mm thick veneer. 2/3 part of vertical unit provided with 300mm deep storage with 4 nos of 19mm thick shelves including 19mm thick commercial board shutter having 5mm thick looking mirror (Shutter size 525 x 1500mm). bottom portion to have 2 nos of opnable drawer rid on telescopic channels. Remaning 1/3 part of unit vertical unit provided with 2 nos of 12mm thick edge polished plain glass,one shutter. top to have half round teak wood beading, including all neccessery hardware and fitting like catcher, hinges, & handles of approved make & design, all edges to have teak wood lipping finished with melamine polish etc. all complete as per approved sample.

104

-

-

... More
Supply of ladies dressing table of size 1050W X 400D X 1950H mm made out of 19mm thick commercial board, top. side & front covered with 2.5mm thick veneer. 2/3 part of vertical unit provided with 300mm deep storage with 4 nos of 19mm thick shelves including 19mm thick commercial board shutter having 5mm thick looking mirror (Shutter size 600 x 1500mm). bottom portion to have one opnable drawer rid on telescopic channels. Remaning 1/3 part of unit vertical unit provided with 2 nos of 12mm thick edge polished plain glass,one drawer & one shutter. top to have 30 x30 mm teak wood cornish, and 1 nos of 1watt Spot light (COB Light). All internal area finishes with 0.8mm thick laminate of approved color. including all neccessery hardware and fitting like catcher, hinges, & handles of approved make & design, all edges to have teak wood lipping finished with melamine polish etc. all complete as per approved sample.

10

-

-

... More
Supply of wall mounted Dressing Mirror with hanging arrangement made out of teak wood frame of size1200x450mm, having 5 mm looking mirror with 6 mm ply on back with dressing box of size 600x375x200 mm made out 19 mm commercial block board having 1mm thick laminate on sides and top provided with 1 nos of drawer rid on telescopic channel including Sprit polishing all complete.

2

-

-

... More
Supply of Wooden console with Ornamental Mirror frame.Console of size 1200x375x750mm made out of teak wood frame ( side rail 90x25mm, orintal legs 90x90mm with heavy carving work on all parts) top with 19mm thick commercial board covered with 2.5 mm thick teak veneer, having 30 x30mm teak wood moulding around top Ornamental wooden Mirror frame made out of teakwood (sides 75 x 35mm & top 120 x 38mm) havind heavy carving work provided with 5mm thick looking mirror. all wooden area finished with melamine polish etc. all complete as per approved sample.

2

-

-

... More
Supply and placing of green room makeup table consist of 2 nos. drawer unit one main table and 1 decorative mirror with light and chair. Drawer unit of size 450x600x750mm made out of 19mm thick commercial board having 4nos of drawer ride on telescopic channel back with 6mm thick commercial ply, all covered with 1mm thick laminate of approved colour. Main table of size 1200x900x450mm made out of 19mm thick commercial board covered with 1mm thick laminate, provided with 2nos of drawers, ride on telecscopic channels. Mirror of size 1200x750x100mm frame made out of 12 mm thick commercial ply (size 100x100mm), providing for LED lights all around the mirror,laminate with approved shade, back with 6mm ply having 5mm thick looking mirror. All edges to have teak wood liping, including all necessary hardware, all internal surface area finished with sprit polish. adjustable stool having Overall height of the chair: LxBxH: 427x427x1220. 202 SWG SS frame work 3 inch dia. main tube with circular base including foot rest, seat with 12 mm commercial ply with 50 mm cushion with good quality having back rest and approved sample etc. all complete as per approved sample.

8

-

-

... More
Supply of Officer Table of size 1500x750x750 mm made out of 19 mm thick commercial board having 1 mm thick laminate on sides & back. Top to have 25 mm thick post formed top .All expose edges have teak wood lipping having 3 nos. drawers rid on telescopic channel all lockable with one lock & Key on right hand side / Left hand side including foot rest all exposed surfaces duly spirit polish etc. all complete as per approved sample.

5

-

-

... More
Supply of writing table of size 1050 x 600 x 750 mm made out of 19mm thick commercial board with 1mm thick laminate on sides, front, & top. provided with 1no Storage with lockable shutter & 1Nos of drawers, ride on telescopic channels with handle of approved make & design. including 70x30mm teak wood foot rest. all exposed edges to have teak wood lipping finished with Sprit polish etc. all complete as per approved sample.

98

-

-

... More
Supply of writing table of size 1200 x 600 x 750 mm made out of one side with teak wood legs 45x45mm, and other sides with 19mm thick commercial board with 2.5mm thick teak veneer, with 2 nos of teak wood long rail of size 70x30mm. Top with 19mm thick commercial board with 1mm thick laminate, top to have addition moulding of 30X20mm provided with 1no Storage with lockable shutter & 1Nos of drawers, ride on telescopic channels with handle of approved make & design. all exposed edges to have teak wood lipping finished with melamine polish etc. all complete as per approved sample.

104

-

-

... More
Supply of Writting Table of size 900x600x750mm made out of 19mm thick commercial board with 1mm thick laminate of approved colour on sides, top & back having 2Nos of drawers ( front with 19mm thick commercial board ,side & back with 12mm thick commercial ply and bottom with 4mm commercial ply) ride on telescopic channel including 1Nos foot rest with teak wood of size 70x30mm all edges to have teak wood lipping,top edge covered with half round teak wood beading and finished with melamine polish etc. all complete as per approved sample.

2

-

-

... More
Supply of Screen Movable (ward bed) side three folds screen with curtains made out of 25 mm dia tublar pipe frame duly oven backed finish etc. all complete as per approved sample.

1

-

-

... More
Supply of side rack with three steel treys of size 900 x 600 x 750 mm made out of 304 grade stainless steel 18 guage tublar section framework and top and bottom have fixed shelf mounted on wheel etc. all complete as per approved sample.

1

-

-

... More
Supply of 5 Step Foldable Aluminium Ladder of size (In Inches): Length: 18.8, Width: 5.1, Height: 67.7, Made from SPECIAL GRADE of Aluminium supplied by Jindal Aluminium Limited which is further ANODISED to enhance life and beauty of Product. The stands are fitted with ANTI-SKID PVC FEET CAPS, to ensure usage on smooth and wet surfaces. The EDGE GUARD at one side of the ladder ensures that your garment does not get torn or pricked. The height of Platform from Floor is 1100mm in open position of approved make Magna Brands or equivalent all complete as per approved sample.

657

-

-

... More
Supply of SS Plate Rack of size 750x250x600mm made out of SS rods of 202 grade having 3Nos of shelves for keeping plates and other vessels including arrangement for hanging etc. all complete as per approved sample.

652

-

-

... More
Supply of Modular Stainless Steel Kitchen Rack (Made From High Grade Stainless Steel) of size 26 x 59 x 76 cm made out of 4Nos of shelves for keeping plates and other vessels including arrangement for hanging etc. all complete as per approved sample.

10

-

-

... More
Supply of SS Plate Rack of size 750x250x600mm made out of SS rods of 202 grade having 3 Nos of shelves for keeping plates and other vessels including arrangement for hanging etc. all complete as per approved sample.

4

-

-

... More
Supply & Fixing of Peg Set of 6 of size 600x100mm made out of 19mm thick commercial board with 1mm thick laminate & lipping on edges having 6 Nos. CP hooks, All finished with melamine polish etc. all complete including hanging/ fixing arrangement and as per approved sample.

1306

-

-

... More
Supply & Fixing of Peg Set of 6 of size 600x100mm made out of 20mm thick teak wood with moulding on edges having 6 Nos. Brass decorative hooks, All finished with melamine polish etc. all complete including hanging/ fixing arrangement and as per approved sample.

10

-

-

... More
Supply of Steel Shoe Rack of size 150D x 800W x 1400mm with 22 guage CRCA Sheet with Quality Powder Coating finish. Sturdy Single Frame Structure with all work done on Automatic CNC Machines. Shoe Rack Back Plate with GI coated Sheet for water resists wall fitting. 150mm Slim Depth with Wall Mounting Provision provided with 4nos of shutters centerly openable and lockable etc. as per approved sample and all complete as per Engineer-in-Charge.

652

-

-

... More
Supply of Sheo Rack of wooden of size 1050W X 400D X 1200H mm. made out of 19 mm thick commercial board covered with 2.5mm thick teak veneer, back with 6 mm thick commercial ply half of unit provided with 2 nos of 19mm thick commerical board shelves and single shutter, 1 drawer at the top rid on telescopic channel. Other half provided with one shutter and soft top with 50mm thick coushion covered with premium quality leatherite/fabric of approved shade. All Internal area finished with 0.8mm thick laminate, all edges to have teakwood lipping, bottom to have 75mm height skirting. all exposed area finished with melamine polish including all necessary hardware & fitting etc. all complete as per Engineer-in-Charge.

10

-

-

... More
Supply of Shoe rack with luggage racks of size 1200x600x750mm made out of 19 mm thick commercial board covered with 1 mm thick laminate having 2 nos of shelves, top provided with 18 x 18 mm teak wood battens, all exposed edges to have teak wood beadind, finished with melamine polish etc. all complete as per approved sample.

2

-

-

... More
Supply of Steel Shoe Rack of size 900x400x900mm. Outer Frame made out of 25x25mm CRC MS tube of 18 Guage & creating 4 nos Shelfs of CRC pipes of 12mm dia & 18 gauge duly Power coated, shoe rack provided with end cap etc. all complete as per Engineer-in-Charge.

6

-

-

... More
Supply of Peg table of size 450x450x450mm made out of teak wood frame ( side rail 70x25mm & legs 45x45mm) top with 19mm thick commercial board and 1mm thick laminate, all exposed edges to have half round beading finished with melamine polish etc. all complete as per approved sample.

1108

-

-

... More
Supply of Bed side Table of size 450 X 450 X 400 mm made out of 19 mm thick commercial board Sides & Front covered with 4mm teak veneer & top to have 1mm thick lamination, 6 mm thick ply on the back side, one drawer made out of side 12 mm thick commercial ply and bottom of 4 mm commercial ply ride on telescopic chanels provided with one open shelf, all exposed edges to be covered with teak wood lipping including finishing with melamine polish etc all complete as per approved sample.

1096

-

-

... More
Supply of Bed side Table of size 450 X 450 X 450 mm made out of 19 mm thick commercial board Sides & Front covered with 2.5mm teak veneer & top to have 1mm thick lamination, 6 mm thick ply on the back side, 2 nos of drawer (side 12 mm thick commercial ply and bottom of 6 mm commercial ply ride on telescopic chanels) 60mm high skirting at bottom all exposed edges to be covered with teak wood lipping including finishing with melamine polish etc all complete as per approved sample.

628

-

-

... More
Supply of Bed side Table of size 600 X 450 X 450 mm made out of 19 mm thick commercial board Sides, top & Front covered with 2.5mm teak veneer & top to have 12mm thick Edge polished plain glass, 6 mm thick ply on the back side, 2 nos of drawer internly finished with 0.8mm thick laminate (side 12 mm thick commercial ply and bottom of 6 mm commercial ply ride on telescopic chanels) 60mm high skirting at bottom all exposed edges to be covered with teak wood lipping including finishing with melamine polish etc all complete as per approved sample.

40

-

-

... More
Supply of Side Unit of siz 1200x6000x715 mm made out of 19 mm thick Commercial boerd & 6 mm thick ply on back, 1mm thick Laminate on sides and front, having 25 mm post formed top provided with 3 nos drawer and keyboard tray rid on telescopic Chanels & one open shelf. all exposed edges to have teak wood beading including finishing with spirit polish etc. all complete as per approved sample.

2

-

-

... More
Supply of Dining Table for 4 person of size 1200x900x750mm made out of teak wood frame ( side rail 90x30mm & legs 70x70mm) top 19mm commercial board and 1mm thick laminate all exposed edges to have half round teak wood beading finished with melamine polish etc. all complete as per approved sample.

556

-

-

... More
Supply of Dining table for 6 persons of size 1800x900x750mm made out of teak wood frame ( side rail 90x30mm & legs 70x70mm) top edge with 38mm thick ( 19mm+19mm) commercial board and 1mm thick laminate of approved shade, all exposed edges to have half round teak wood beading finished with melamine polish etc. all complete as per approved sample.

120

-

-

... More
Supply of Dining Table for 8 Persons of size 2400 X 1050 X 750 mm made out of teak wood frame (side rail 120 X 30 mm & orintal legs 90x90mm with light carving work on all parts) top with19mm commercial board covered with 16mm thick italian marble having polished double edge & taper moulding. all exposed edges to have lipping finished with melamine polish etc. all complete as per approved sample.

5

-

-

... More
Supply dining table for 6 person (Brushed SS with granite top) of size 1800x750x750 mm made out of and 40x20 mm 16 gauge 304 grade section (for top frame,Crossed Legs, Foot rest), at Top 16mm thick granite stone with all edges double moulding dully polished etc. all complete as per approved sample.

8

-

-

... More
Supply dining table for 4 person (Brushed SS with granite top) of size 1200x750x750 mm made out of and 20x20 mm 16 gauge 304 grade section (for top frame, Curved Legs, bottom frame), at Top 16mm thick granite stone with all edges double moulding dully polished etc. all complete as per approved sample.

17

-

-

... More
Supply of chair size 380x330x800 mm made out of SS frame and seat with 50mm thick foam on 12mm thick commercial ply and covered with leathrite of approved design and sample.

82

-

-

... More
Supply of chair size 380x330x800 mm made out of SS frame and seat with 12mm thick rubber wood and finished with melamine polish of approved shade etc all complete as per approved sample.

36

-

-

... More
Supply of three seater bench cross beam shall be made up of black powder coated rectangular M.S. ERW tube having 8± 0.03 cm x 4 ± 0.03cm x 0.2 ± 0.016 cm size. Leg and armrest shall be chrome plated made of cold rolled steelwith 0.12±0.013cm thickness. Seat back shell shall be 1.6mm thick powder coated perforated shall made form cold rolled M.S sheet (DIN 1623 Part 1 ST-12 Grade) 0.14±0.013 cm thickness. The side bar shall be made of chrome plated solid steel 3±0.03cm x 1.2±0.3cm (DIN 174) with fluting and plastic inserts. The shell shall be assemled on the cross beam with help of M8 bolts (Per sheet-8 nos seat to bracket and 4 nos. bracket to cross beam). Overall dimensions shall be seat height -40cm height-67cm, width & depth of chair as measured from pedestal -width-163cm and depth-57cm etc. complete as per approved sample.

14

-

-

... More
Supply of MS Pigon hole rack of size 1980 X 910 X 480 mm having 8 nos open equal size compartments. body and shelves fabricated from 22 gauge thick CRC MS plane sheet. All surface of Almirah shall be Powder Coated of approved colours/shades all as per Engineer-in-Charge.

2

-

-

... More
Supply of Stainless Steel revolving stool of Overall Size: 480mm To 670mm H. Tubular tripod base of 25.4 x 14 g ERW tube.STAINLESS STEEL top. Height adjustment by screw. 300mm dia. The legs fitted with high quality PVC shoes with nylon reinforcement. All mild steel components should be thoroughly in-house pretreated chemically to remove rust, grease, oil, etc. by dip tank processes, including separate degrasing, pickling, phosphating each followed by water rinsing passivating and hot air drying to give phosphate coating. The treated metal surface should then be coated in-house with epoxy polyester powder with paint film thickness of 60 microns (minimum) and oven baked at 180 deg. to 200 deg. centigrade. All STAINLESS STEEL used should be of 304 grade as per approved sample.

21

-

-

... More
Supply of four seater Stainless steel bench made out of 18 gauge 304 grade SS sheet (perforated on top). 2 nos vertical 45mm thick support, fixeed with ground as per approved sample.

23

-

-

... More
Supply of Personal Locker unit of size 1980 X 910 X 480 mm having 8 Lockers individual Shutters with locking arrangement.body and shelves fabricated from 22 gauge thick CRC MS plane sheet & doors with 20 gauge thick CRC MS plane sheet. . All surface of Almirah shall be Powder Coated of approved colours/shades all as per Engineer-in-Charge.

10

-

-

... More
Supply of pool chair for swimming pool having specification:- Color: Brown Red Material: Fir Wood Flat Dimensions: 71.7"L x 23.6"W x 13.8"H Adjustable Dimensions: 65"L x 23.6"W x 32.7"H; 63"L x 23.6"W x 35.4"H Seat Dimensions: 41.7"L x 22.8"W x 13.8"H Side Pullout Tray Size: 13"L x 9.8"D x 2"H Backrest Size: 20.1"W x 28"H Back Wheel Size: Φ4.3" x 0.7"T Weight Capacity: 250 lbs Net Weight: 32.6 lbs etc, all complete as per approved sample.

15

-

-

... More
Supply of umbrella (9' Octagon) pulley and pin operated having specification:- Umbrella shall have 2" solid, one-piece powder coated pole (96"), flexible fiberglass ribs with molded nylon joints, hubs, end tips, canopy features a single sewn in vent and sunbrella marine or furniture grade fabric, high resistance to wind, corrision, rust and wraping, an stell umbrella base (24"x24"x18") 130lbs, or use freestanding in an umbrella sleeve etc, all complete as per approved sample.

7

-

-

... More
Supply of Examination couch with upholstered top upper section with three drawers adjustable upholstered back rest. Lower section with lockable slide door cabinet swining tray for B.P apparatus. Chemically pre treated and epoxy power coated / oven baked enameled backrest. size1890L x 510W x 820H mm Platform size 450L x 510W mm all complete as per approved sample.

1

-

-

... More
Supply Serving table (Brushed SS with granite top) of size 1200x600x750 mm made out of and 40x20 mm 16 gauge 304 grade section (for top frame, Legs, bottom rail & support), at Top 16mm thick granite stone with all edges double moulding dully polished etc. all complete as per approved sample.

2

-

-

... More
Supply of Srvice Trolley of size 900 x 600 x 750 mm made out of 304 grade stainless steel 18 guage tublar section framework and top and bottom have fixed shelf mounted on wheel etc. all complete as per approved sample.

6

-

-

... More
Supply of servicing table of size 900x900x750 mm with teak wood frame (side rail 90x30mm and legs 70x70mm) top to have 19 mm thick commercial board with 1mm thick laminate all exposed edges to have liping finfished with Sprit polish etc. all complete as per approved sample.

6

-

-

... More
Supply of pantry table of size 1200x600x750 mm with teak wood frame top to have 19 mm thick commercial board with 1 mm thick laminate and 30x30 mm thick teak wood moulding around table top 70x70 mm thick decorative teak wood legs duly finished sprit polish etc. all complete as per approved sample.

3

-

-

... More
Supply of cook house table 2 tier (SS) of size 1200x600x840 mm made out of and 40x40 mm 16 gauge 304 grade section, at Top & bottom provided with 20 gauge 304 grade SS sheet with 2 folds on all four sides with CNC machine, all corners dully welded with mig welging, etc. all complete as per approved sample.

8

-

-

... More
Supply of Gents Dressing table of size 600 x 400 x1950mm made out of 19 mm thick commercial board covered with 2.5mm thick veneer. Upto 600mm having 400mm depth having 2 nos drawer rid on telescopic channels. above 600mm with 300mm depth having 4 nos of19mm thick commercial board shelves under 19 mm thick shutter having 5mm thick looking mirror, top to have 30 x30 mm teak wood cornish, and 1 nos of 1watt Spot light (COB Light). All internal area finishes with 0.8mm thick laminate of approved color. including all neccessery hardware and fitting like catcher, hinges, & handles of approved make & design, all edges to have teak wood lipping finished with melamine polish etc. all complete as per approved sample.

548

-

-

... More
Supply of Gents Dressing table of size 600 x 400 x1950mm made out of 19 mm thick commercial board covered with 2.5mm thick veneer. Upto 600mm having 400mm depth having 2 nos drawer rid on telescopic channels. above 600mm with Dressing Mirror with hanging arrangement made out of teak wood frame of size1200x450mm, having 5 mm looking mirror with 6 mm ply on back, top to have half round beading of teak wood. including all neccessery hardware and fitting like catcher, hinges, & handles of approved make & design, all edges to have teak wood lipping finished with Melamine polish etc. all complete as per approved sample.

208

-

-

... More
Supply of wall mounted Dressing Mirror with hanging arrangement made out of teak wood frame of size1200x450mm, having 5 mm looking mirror with 6 mm ply on back with dressing box of size 600x375x200 mm made out 19 mm commercial block board having 1mm thick laminate on sides and top provided with 1 nos of drawer rid on telescopic channel including Sprit polishing all complete as per approved sample.

10

-

-

... More
Supply of Staff/Clerk Table of size 1200x600x750 mm made out of 19 mm thick commercial board having 1 mm thick laminate on sides & back. Top to have 25 mm thick post formed top .All expose edges have teak wood lipping having 3 nos. drawers rid on telescopic channel all lockable with one lock & Key on right hand side / Left hand side including foot rest all exposed surfaces duly melamine polish etc. all complete as per approved sample.

9

-

-

... More
Supply of Computer table of size 1050x600x750mm, made out of 19mm thick commercial board having 1mm thick laminate on top sides & front of approved shade, provided with 2 Nos sliding tray & one lockable drawer (one for key board & and other for CPU ,ride on telescopic channel including handle of approved make), all exposed edges covered with teak wood beading & finished with Sprite polish etc. all complete as per approved sample.

551

-

-

... More
Supply of Computer table of size 1350x600x750mm made out of 19mm thick commercial board having 1mm thick laminate on top, side & front with 2.5mm thick teak veneer, one side provided with 1 drawer unit consisting of 1no Storage with lockable shutter & 1Nos of drawers, ride on telescopic channels, and other side with 1 Nos sliding tray for CPU and 1Nos of drawers, ride on telescopic channe. middle of table with 1 no of key board tray & one open shelve under the top including handle of approved make, all exposed edges covered with teak wood beading & finished with melamine polish etc. all complete as per approved sample.

104

-

-

... More
Supply of Computer table cum cabinet Unit of size 1500W x 1950H (upto working hight 600mm depth and above working hight 400mm) made out of 19mm thick commercial board covered with 2.5mm thick teak venner, back with 6mm thick commercial ply, top to have 12mm thick edge polished plain glass. Upto 750mm hight computer table having 1nos of drawer ride on telescopic chanels, 3 nos vertical divider of 19mm thick commercial board, provided with 2 nos of sliding tray (1 for CPU and 1 for Keyboard),1no Storage with lockable shutter, one open shelve under the top. from 750mm hight to 1350mm shell be provided with 10mm thick soft pin board covered with fabric of approved color. Above 1350 to 1950mm hight, storage unit to be provided with glazed shutters 5mm thick plain glass fixed with wooden frame having one horizontal & one vertical divider of 19mm thick commercial board, all internal area finished with 0.8mm thick lamininate and outer face finished with teak veneer, provided with LED Light with melamine polish etc. all complete as direction of Engineer-in-Charge.

10

-

-

... More
Supply of wall hung TV cabinet unit with panelling of overall outer size 1800 x 1500 x 400mm. bottom storage unit of size1800 x 400 x 400mm with10mm thick plain edge polished glass mounded on ss studs, made out of 19mm thick commercial board covered with 2.5mm thick teak veneer, front side edge to have 40.5mm thickness (19mm+19mm+2.5mm). Lower portion to have 2Nos. drawer ride on telescopic channel , 3Nos.open shelves. Above Bottom unit panelling to done with 19mm thick commercial board covered with 2.5mm thick teak veneer, with side edged 40.5mm thickness (19mm+19mm+2.5mm) with 18 x 8mm grove designe. having provision for wiring behind panelling, top portion to have 40mm thick wooden shelve. panelling should be good enugh to carry load of a LED screen upto 100 kgs. All exposed edges to have teak wood lipping, all inner area finished with 0.8mm thick laminate. finished with melamine polish etc. all complete as per approved sample.

2

-

-

... More
Supply of Table of size 900x600x750mm made out of 19mm thick commercial board with 1mm thick laminate of approved colour on sides, top & back having 2Nos of drawers ( front with 19mm thick commercial board ,side & back with 12mm thick commercial ply and bottom with 4mm commercial ply) ride on telescopic channel including 1Nos foot rest with teak wood of size 70x30mm all edges to have teak wood lipping,top edge covered with half round teak wood beading and finished with melamine polish etc. all complete as per approved sample.

1

-

-

... More
Supply of Counter table with side rack of size 1200 X 500 X 800 mm made out of stainless steel and provided with 2 Nos. Shelves and one lockable drawer ride on telescopic channel etc. all complete as per approved sample.

4

-

-

... More
Supply of Teapoy of size 400x400x400mm made out of teak wood frame ( side rail 70x25mm & legs 38x38mm) top with 19mm thick commercial board and 1mm thick laminate all exposed edges to have 20 x 20mm thick teak wood Cornish finished with melamine polish etc. all complete as per approved sample.

210

-

-

... More
Supply of Teapoy of size 400x400x400mm made out of teak wood frame (side rail 70x25mm & orintal legs 38x38mm) top with 19mm thick commercial board and 2.5mm thick teak veneer all exposed edges to have 20 x 20mm thick teak wood Cornish finished with melamine polish etc. all complete as per approved sample.

20

-

-

... More
Supply of Teapoy verandah of ( Moulded plastic) (Trade pattern of make Neelkamal model no CENTBLE 4 / Supreme or equivalent) as per sample approved.

114

-

-

... More
Supply of CSD Store rack for wall single side with four nos shelves which is made by steel duly powdercoated, rust proof, long durable, easy to installation, for household provision, kitchen, appliances, drinks etc. as per room requirement approx size 1200(L)x1800(H)x400(D) mm.

50

-

-

... More
Supply of CSD Store rack double sides with four nos shelves which is made by steel duly powdercoated, rust proof, long durable, easy to installation, for household provision, kitchen, appliances, drinks etc. as per room requirement approx size 1200(L)x1800(H)x800(D) mm.

10

-

-

... More
Supply of TV cabinet of size1600x450x600mm with10mm thick plain edge polished glass mounded on ss studs, made out of 19mm thick commercial board covered with 1mm thick laminate, front side edge to have 39mm thickness(19mm+19mm+1mm). Center portion to have 2Nos.open shelves & one side with 2Nos. drawer ride on telescopic channel and other side provided with 1Nos. openable shutter with catches & hinges including handles &100mm high ss legs. All exposed edges to have teak wood lipping , back with 6mm thick commercial ply finished with melamine polish etc. all complete as per approved sample.

104

-

-

... More
Supply of TV cabinet unit with panelling of overall outer size 2100 x 2100 x 400mm. bottom storage unit of size2100 x 400 x 600mm with10mm thick plain edge polished glass mounded on ss studs, made out of 19mm thick commercial board covered with 2.5mm thick teak veneer, front side edge to have 40.5mm thickness (19mm+19mm+2.5mm). Lower Center portion to have 2Nos. drawer ride on telescopic channel , 2Nos.open shelves on both sides. provided with 150mm hight SS legs. Above Bottom unit panelling to done with 19mm thick commercial board covered with 2.5mm thick teak veneer, with side edged 40.5mm thickness (19mm+19mm+2.5mm) with 18 x 8mm grove designe. having provision for wiring behind panelling, top portion to have 40mm thick wooden shelve. panelling should be good enugh to carry load of a LED screen upto 100 kgs. All exposed edges to have teak wood lipping, all inner area finished with 0.8mm thick laminate. finished with melamine polish etc. all complete as per approved sample.

10

-

-

... More
Supply of wall hang TV cabinet unit with panelling of overall outer size 1800 x 1500 x 400mm. bottom storage unit of size1800 x 400 x 400mm with10mm thick plain edge polished glass mounded on ss studs, made out of 19mm thick commercial board covered with 2.5mm thick teak veneer, front side edge to have 40.5mm thickness (19mm+19mm+2.5mm). Lower portion to have 2Nos. drawer ride on telescopic channel , 3Nos.open shelves. Above Bottom unit panelling to done with 19mm thick commercial board covered with 2.5mm thick teak veneer, with side edged 40.5mm thickness (19mm+19mm+2.5mm) with 18 x 8mm grove designe. having provision for wiring behind panelling, top portion to have 40mm thick wooden shelve. panelling should be good enugh to carry load of a LED screen upto 100 kgs. All exposed edges to have teak wood lipping, all inner area finished with 0.8mm thick laminate. finished with melamine polish etc. all complete as per approved sample.

2

-

-

... More
Supply of double top type Reception counter having 600 mm depth & 1050 mm higher (working top 750 mm) made out of 19 mm thick commercial board covered with 2.5mm thick teak veneer (inner oppen area and all other exposed area) all edges to have 5 mm teak wood lipping working top (600mm deep) and upper top (300mm deep) to have 16 mm granite stone under top decorative 50mm x 12 mm moulding, provided with 3 drawers, one shutter cabinet & one open shelve. Making various panels with 12mm thick commercial ply and teak venner having alround teak wood moulding (20 x 20mm). Back having 5mm thick looking mirror work as desired by EIC. skirting 75mm. finished with melamine polish etc. all complete. all as per approved drawing and as per direction of Engineer-in-charge.

10

-

-

... More
Supply & Fixing of aluminum powder coated Drapery/ Curtain Rods of 30mm dia of approved make Vista or equivalent with rings including brackets walls and all necessary fitting & hardware etc. all complete as per Engineer-in-Charge.

5000

-

-

... More
Supply of Bath Mat of size 575X375mm of standard make (Prestigious , Floormat brand or equivalent) and as per approved sample.

250

-

-

... More
Supply of wall hung Bath cabinet of size 1200x 375x375mm made out of 19mm thick commercial board wuth externly finished with 1mm thick laminate and internaly finishes with 0.8mm thick laminate having one door and provided with 3 nos of shelfs, all edges to have teal wood lipping finished with melamine polish. all complete as per approved sample.

228

-

-

... More
Supply of Crockery Unit of size 1800 x 400 x 1950mm made out of 19mm thick commercial board, back with 6mm thick commercial ply, top to have 16mm thick italian marble having polished double edge & taper moulding. Sides & front to have 2.5 mm thick teak veneer. Upto 750mm hight side board having 10nos of drawer ride on telescopic chanels, 3 nos vertical divider of 19mm thick commercial board, thick commercial board. from 750mm hight to 1350mm shell be provided with 19mm thick back along with one open shelve covered with 2.5 mm thick teak ply. Above 1350 to 1950mm hight, storage unit to be provided with glazed shutters 5mm thick plain glass fixed with wooden frame having one horizontal & one vertical divider of 19mm thick commercial board, all internal area finished with 0.8mm thick lamininate and outer face finished with teak veneer, provided with LED Light with melamine polish etc. all complete as direction of Engineer-in-Charge.

5

-

-

... More
Supply of double top type bar counter having 600 mm depth & 1200 mm higher (working top 750 mm) made out of 19 mm thick commercial board covered with 2.5mm thick teak veneer all edges to have 5 mm teak wood lipping working top to have 16 mm granite stone and upper top (serving top) with 12 mm edge polished plain glass (width 300 mm) provided with 3 drawers, one shutter cabinet & one open shelve. Making various panels with 12mm thick commercial ply and teak venner having alround teak wood moulding (20 x 20mm). Back having 5mm thick looking mirror work as desired by EIC. skirting 75mm and foot rail madeout of 32mm dia 16 guage SS hollow section. finished with melamine polish etc. all complete. all as per approved drawing and as per direction of Engineer-in-charge.

8

-

-

... More
Supply and fixing of bar back cabinet 450 mm deep upto height of 750 mm and 300 mm for remaining height, made out of 19 mm thick commercial board top portion to have wine glass hanging arangment, Sides with glazed shutter with 5 mm thick plain glass and 19 mm thick commercial block board, back with 6mm thick commercial ply and 5 mm thick looking mirrorand bottom making provision to keeping wine bottles with 19 mm thick commercial board finished with 1mm thick laminate, top at 750mm hight provided with 16mm thick granite stone, all exposed edges to have teak wood beading. top to have 30x30mm teak wood beading alround top, with LED light as per EIC (3 to 5 nos). including locking arrangement with duplicate key, handles and catches of approved make & design finished with melamine polish etc all complete as per approved sample.

8

-

-

... More
Supply of Projector trolly of size 600 x 600 x 750mm made out of 19mm thick commercial board having 1 mm thick laminate of approved shade, top provided with 3 sides 20mm raised, 1 Nos. sliding tray ride on telescopic channel, one lockable drawer (front with 19mm thick commercial block board, sides with 12mm thick commercial ply and bottum with 4mm thick commercial ply ) ride on telescopic channel and shutter , back to have 6 mm commercial ply with hole for wiring,all exposed edges covered with teak wood beading & finished with sprit polish etc. all complete as per approved sample.

1

-

-

... More
Supply and placing of Side Rack of size 1050 x450 x 750mm made out of 19mm thick commercial board having 1 mm thick laminate of approved shade,side with teak board, 2 Nos. sliding tray (one for key board of size 525x400mm & other for CPU at bottum portion) ride on telescopic channel, one lockable drawer (front with 19mm thick commercial block board, sides with 12mm thick commercial ply and bottum with 4mm thick commercial ply ) ride on telescopic channel and open shelf , back to have 6 mm commercial ply with hole for wiring,all exposed edges covered with teak wood beading & finished with sprit polish etc. all complete as per approved sample.

7

-

-

... More
Supply of Console table of size 1200x450x750mm made out of 19mm thick commercial board, covered with 2.5mm thick veneer on sides, front & top. provided with 3 nos of drawers rid on telescobip channel & 1 no shutter, bottom to have 75mm high skirting. back with 6mm thick commercial ply, including handle of approved make & design and catches, top to have 20x12mm teak wood beading all exposed edges to have teak wood lipping, all internal area finished with 0.8mm thick laminate and outer surface area finished with melamine polish etc. all complete as direction of Engineer-in-Charge.

114

-

-

... More
Supply of 5 feet Stainless Steel Jumbo Cloth Dryer (Drying Length 45 Feet). Dimensions (In Inches): Open- Length: 28, Width: 39, Height: 64, Closed- Length: 4.5, Width: 39, Height: 48 Weight: 5.7 Kg All complete as per approved sample.

548

-

-

... More
Supply of Display cabinet size 1950 X 900 X 400mm made out of 19 mm thick commercial board covered with 2.5 mm thick teak veneer on outer sides and all internal area to be finished with 0.8 mm Laminate, back with 19mm thick commercial board. Making 5 compartments with 4 nos of shalves 12mm thick edge polished plain glass. both sides of unit having 6mm thick etched glass, with2 nos of teak wood of size 45 x45xmm with light carving work in front. Provided with Teak wood glazed shutters having light carving work, with 5 mm thick etched glass. Top to have 150mm skirting with two runs of teak wood moulding (one with 30X30 teak wood cornish and other with 15 X15mm) including all neccessery fittings, provided with LED Light at top, all exposed edges to have teak wood li[pping finished with melamine polish.etc all complete as per Engineer-in-Charge.

208

-

-

... More
Supply of Executive display cabinet size 1950 X 1050 X 400mm made out of 19 mm thick commercial board covered with 2.5 mm thick teak veneer on outer sides and all internal area to be finished with 0.8 mm Laminate, back with 19mm thick commercial board. Making 5 compartments with 4 nos of shalves 12mm thick edge polished plain glass. both sides of unit having 6mm thick etched glass, with 2 nos of teak wood of size 45 x45xmm with light carving work in front. Provided with Teak wood glazed shutters having light carving work, with 5 mm thick etched glass. Top to have 150mm skirting with two runs of teak wood moulding (one with 30X30 teak wood cornish and other with 15 X15mm) including all neccessery fittings, provided with LED Light at top, all exposed edges to have teak wood li[pping finished with melamine polish.etc all complete as per Engineer-in-Charge.

10

-

-

... More
Supply of Crockery Unit of size 1800 x 400 x 750mm made out of 19mm thick commercial board, top & sides to have 1 mm thick laminate having one horizontal & one vertical divider of 19mm thick commercial board, back with 6mm thick commercial ply , front to have Door having 4mm thick plain glass including handle of approved make & design and catches, top to have 20x12mm teak wood beading finished with sprit polish etc. all complete as direction of Engineer-in-Charge.

4

-

-

... More
Supply of Crockery Unit of size 1800 x 400 x 750mm made out of 19mm thick commercial board, top & sides to have 1 mm thick side board laminate having one horizontal & one vertical divider of 19mm thick commercial board, back with 6mm thick commercial ply , front to have Door with teak wood frame of size 45x30mm having 4mm thick plain glass including handle of approved make & design and catches, top to have 20x12mm teak wood beading finished with melamine polish etc. all complete as direction of Engineer-in-Charge.

652

-

-

... More
Supply of Crockery Cabinet of size 2100 x 450 x 750 mm made out of 19 mm thick commercial board sides and front with 2.5mm thick teak veneer, top with1 mm thick lamination having 3 nos of drawers rid on telescopoic channel and wooden glazed shutters with 5mm thick plain glass & one shelve, top alround with 30 x30mm teak wood moulding,75mm high skirting including melamine polish etc all complete as per approved sample.

4

-

-

... More
Supply of servicing / pantry counter of size 750x750 mm made out of 19 mm thick commercial board with 1mm thick laminate and 16mm thick granite stone on top, having 100mm skirting with 12mm thick commercial ply and SS finish laminate, provided with 300mm deep nitch of approved size (Each nitch provided with 1/2 nos of LED Spot light), all exposed edges to have teak wood lipping duly finished melamine polish etc. all complete as per approved sample.

8

-

-

... More
Supply of steel slotted rack of size 1950 X 900 X 450 mm with 5 shelves of approved make antirust painting etc. all complete as per approved sample.

3

-

-

... More
supply of Ironing table of size 1200 X400 X900mm top made out of 18mm thick Partical board with soft upholstered & stand made out of MS pipe of 25mm dia including arrangement for keeping iron. etc. all complete as per approved sample.

118

-

-

... More
PART-T : GYM EQUIPMENTS WORKS

-

-

-

... More
Supply, installation, testing & commissioning of Treadmill as per following specifications:- Fitline-Treadmill S900 4 Hp Continous/ 8 Hp Peak AC Industrial Commercial Motor. 2.2 KW Korean Digital Drive Belt area : 22" Wide x 64" Long Broad Side Strips for Better Foot Grip Textured Belt for Better running Grip Broad handle Bars for Design and User Safety Time, Speed, Distance, Calorie and Contact Pulse Rate Sensors Speed : 0-20 km/ Hr Incline : 0-20 Levels Treadmill weight : 210 Kgs User weight : 300 kgs

11

-

-

... More
Supply, installation, testing & commissioning of Fitline-Elliptical (Cross Trainer) as per following specifications:- Product Number: Cem 01 Elliptical Resistance Range: 16 Levels Heart Rate Sensors on front bar Internal generator w/external power supply. Broader foot base for better ground stability. LED Display for brighter & better view. Display shows : Speed,Distance,Time,Calorie Maximum User Weight: 175 kg

6

-

-

... More
Supply, installation, testing & commissioning of Fitline-Elliptical (Cross Trainer) as per following specifications:- Product Number: Cem 01 Elliptical Pre-Set Progams : Manual, Interval, Weight Loss Target,Heart Rate, Fit Test, Random, Warm Up and Warm Down. Display Shows : Time, Speed, Distance, Calories,Contact Heart Rate. Resistance Levels : 1-16 Levels LED Display for Better View User Weight : 200 Kgs Product Weight : 110 Kgs

3

-

-

... More
Supply, installation, testing & commissioning of Fitline- Upright Bike as per following specifications:- Model No: Phantom 8020 Led Display for Brighter and better View Display Show : Speed, Distance, Time, calories Heart rate. Resistance Level : 20 Levels User Weight : 200 Kgs Massive and Larger Seat for All Body Weights Double Color for Fashionable appearance and Great Looks. Pedal Strap for Better Foot Grip. QUOTATION FOR FITNESS EQUIPMENT internal Generator with External Power Supply Minimum RPM - 60rpm

5

-

-

... More
Supply, installation, testing & commissioning of Fitline-Recumbent Bike as per following specifications:- Product Number: 8010 Resistance : 1 to 20 Minimum Rpm- 60 Rpm Minimum Watt- 25 W Max User Wt: 200 kg Adjustable Seat position Self Generator Display shows : Speed,Distance,Time,Calorie, Target Pulse,Constant Watt,RPM,Heart Rate

5

-

-

... More
Supply, installation, testing & commissioning of Fitline-Spin Cycle Product Number: Model no- 5809

2

-

-

... More
Supply, installation, testing & commissioning of Fitline- Shoulder/Chest Dual Series Product Number: Model FITLINE DUAL SERIES

1

-

-

... More
Supply of Fitline- Lat/Row Dual Series Product Number: Model FITLINE DUAL SERIES

1

-

-

... More
Supply, installation, testing & commissioning of Fitline-Leg Extn/Leg Curl Dual Series Product Number: Model FITLINE DUAL SERIES

1

-

-

... More
Supply, installation, testing & commissioning of Fitline- Leg Press Product Number: Model FITLINE LEG PRESS

1

-

-

... More
Supply, installation, testing & commissioning of Fitline- Cross Fit Product Number: Model 360 M

1

-

-

... More
Supply, installation, testing & commissioning of Multi Gym 4 Station 518 Bk as per following specifications:- 4 Weight Stack Multi Gym 4 Users Can Workout at the same time Fully Enclosed now, For Injury Free exercises and User Safety. Lat Pull Down in Unique Machine Guided Path of Movement Leg Extension, Chest Press, Incline Chest Press Lat Pull Down, Biceps, Triceps, Mid Row etc.

2

-

-

... More
Supply of Fitline-Massage Chair as per following specifications:- 3 D Sensing that measure a length spine Massage therapy air bag massage from shoulder to feet, for auto modes. Air squesing and rolling.

1

-

-

... More
Supply of Fitline- Dumbbell Rack MT-030 TWIN TIER DUMBBELL RACK.

2

-

-

... More
Supply of Fitline-Flat bench MT-023A OLYMPIC FLAT BENCH.

2

-

-

... More
Supply of Fitline- Olympic Incline bench MT-025A OLYMPIC INCLINE BENCH.

1

-

-

... More
Supply of Fitline- Olympic Decline bench MT-024 OLYMPIC DECLINE BENCH.

1

-

-

... More
Supply of Fitline- Adjustable bench MT-037A ADJUSTABLE BENCH

2

-

-

... More
Supply of Fitline- Flat Bench MT-036A FLAT BENCH

2

-

-

... More
Supply of Fitline- Weight Tree MT 041.

2

-

-

... More
Supply of Fitline- Rubberised Dumbbells.

600

-

-

... More
Supply of Olympics Rubberised Weight Plates.

580

-

-

... More
Supply of 7 ft Standard Olympic Bar.

3

-

-

... More
Supply of EZ Clurl Bar Olympic (5 ft )

1

-

-

... More
Supply of Yoga mat.

4

-

-

... More
Supply of Gym ball.

2

-

-

... More
PART-U : LIFT WORK

-

-

-

... More
Supplying, installation, Testing, and commissioning of 10 pasegger (680kg) gearless & machine room less lift having superior technology i.e Regen drive, belts, pulse monitoring unit, concealed ceiling with cross flow fan, LCD monochrome display in car and at landings.contract speed of 1.5 MPS serving different floors in the existing lift shaft as per detailed specification as under, complete with modern interior SS Hairline finish, hall buttons, combined with digital CPI on all floors car, operating panel with button and digital CPI suitable for Microprosessor based Simplex collective selective control with /without attandent opreation, top of car inspection box, battrey operated alarm bell, emergency light electronic door detector, elevoice (floor annoucement (system), sills at all landings, header hanger with door frame etc complete as required. (a) Speed 1.5 MPS (b) Floors:- B+G+12 (c) Travel:- B+G+12 (40950 mm approximate) (d) Stops & Opening : from 1st door opeing level to last door opeing bottom level.

12

-

-

... More
(e) Controller: Microprosessor based & AC variable voltage & variable ferquency (f) Automatic Rescue Device complete with Dry Maintenance Free Batteries as required . (g) Opration: Microprocessor based Ac variable voltege variable frequency (ACVVVF) controller. Simplex collective selective with /without attendant. (h) Power - 415 Volts, 3 Phase, 50Hz, 4 wire system. (i)Type of doors: (j) Car: Power operated, center opening horizontal sliding stainless steel (Hailine) Stainless Steel false ceiling and granite flooring of approved shade/colour. (k) Landng doors: SS landing doors in Hairline (l)Handrail of sufficiant length at 900 mm above floor level to be fixed in the lift car. (m) Braille operating buttons system as requred in each car and at all levels. The button shall be placed in suitable location for acccess of handicapped person. (n) 800 center opening, 2000 mm car height

-

-

-

... More
Supplying, installation, Testing, and commissioning of 10 pasegger (680kg) gearless & machine room less lift having superior technology i.e Regen drive, belts, pulse monitoring unit, concealed ceiling with cross flow fan, LCD monochrome display in car and at landings.contract speed of 1.5 MPS serving different floors in the existing lift shaft as per detailed specification as under, complete with modern interior SS Hairline finish, hall buttons, combined with digital CPI on all floors car, operating panel with button and digital CPI suitable for Microprosessor based Simplex collective selective control with /without attandent opreation, top of car inspection box, battrey operated alarm bell, emergency light electronic door detector, elevoice (floor annoucement (system), sills at all landings, header hanger with door frame etc complete as required. (a) Speed 1.5 MPS (b) Floors:- G+12 (c) Travel:- G+12 (37800mm approximate) (d) Stops & Opening : from 1st door opeing level to last door opeing bottom level.

4

-

-

... More
(e) Controller: Microprosessor based & AC variable voltage & variable ferquency (f) Automatic Rescue Device complete with Dry Maintenance Free Batteries as required . (g) Opration: Microprocessor based Ac variable voltege variable frequency (ACVVVF) controller. Simplex collective selective with /without attendant. (h) Power - 415 Volts, 3 Phase, 50Hz, 4 wire system. (i)Type of doors: (j) Car: Power operated, center opening horizontal sliding stainless steel (Hailine) Stainless Steel false ceiling and granite flooring of approved shade/colour. (k) Landng doors: SS landing doors in Hairline (l)Handrail of sufficiant length at 900 mm above floor level to be fixed in the lift car. (m) Braille operating buttons system as requred in each car and at all levels. The button shall be placed in suitable location for acccess of handicapped person. (n) 800 center opening, 2000 mm car height

-

-

-

... More
Supplying, installation, Testing, and commissioning of 10 pasegger (680 kg) gearless & machine room less lift having superior technology i.e Regen drive, belts, pulse monitoring unit, concealed ceiling with cross flow fan, LCD monochrome display in car and at landings.contract speed of 1.5 MPS serving different floors in the existing lift shaft as per detailed specification as under, complete with modern interior SS Hairline finish, hall buttons, combined with digital CPI on all floors car, operating panel with button and digital CPI suitable for Microprosessor based Simplex collective selective control with /without attandent opreation, top of car inspection box, battrey operated alarm bell, emergency light electronic door detector, elevoice (floor annoucement (system), sills at all landings, header hanger with door frame etc complete as required. (a) Speed 1.5 MPS (b) Floors:- B+G+11 (c) Travel:- B+G+11 (37800mm approximate) (d) Stops & Opening : from 1st door opeing level to last door opeing bottom level.

4

-

-

... More
(e) Controller: Microprosessor based & AC variable voltage & variable ferquency (f) Automatic Rescue Device complete with Dry Maintenance Free Batteries as required . (g) Opration: Microprocessor based Ac variable voltege variable frequency (ACVVVF) controller. Simplex collective selective with /without attendant. (h) Power - 415 Volts, 3 Phase, 50Hz, 4 wire system. (i)Type of doors: (j) Car: Power operated, center opening horizontal sliding stainless steel (Hailine) Stainless Steel false ceiling and granite flooring of approved shade/colour. (k) Landng doors: SS landing doors in Hairline (l)Handrail of sufficiant length at 900 mm above floor level to be fixed in the lift car. (m) Braille operating buttons system as requred in each car and at all levels. The button shall be placed in suitable location for acccess of handicapped person. (n) 800 center opening, 2000 mm car height

-

-

-

... More
Supplying, installation, Testing, and commissioning of 10 pasegger (680 kg) gearless & machine room less lift having superior technology i.e Regen drive, belts, pulse monitoring unit, concealed ceiling with cross flow fan, LCD monochrome display in car and at landings.contract speed of 1.5 MPS serving different floors in the existing lift shaft as per detailed specification as under, complete with modern interior SS Hairline finish, hall buttons, combined with digital CPI on all floors car, operating panel with button and digital CPI suitable for Microprosessor based Simplex collective selective control with /without attandent opreation, top of car inspection box, battrey operated alarm bell, emergency light electronic door detector, elevoice (floor annoucement (system), sills at all landings, header hanger with door frame etc complete as required. (a) Speed 1.5 MPS (b) Floors:- G+11 (c) Travel:- G+11 (34650mm approximate) (d) Stops & Opening : from 1st door opeing level to last door opeing bottom level.

4

-

-

... More
(e) Controller: Microprosessor based & AC variable voltage & variable ferquency (f) Automatic Rescue Device complete with Dry Maintenance Free Batteries as required . (g) Opration: Microprocessor based Ac variable voltege variable frequency (ACVVVF) controller. Simplex collective selective with /without attendant. (h) Power - 415 Volts, 3 Phase, 50Hz, 4 wire system. (i)Type of doors: (j) Car: Power operated, center opening horizontal sliding stainless steel (Hailine) Stainless Steel false ceiling and granite flooring of approved shade/colour. (k) Landng doors: SS landing doors in Hairline (l)Handrail of sufficiant length at 900 mm above floor level to be fixed in the lift car. (m) Braille operating buttons system as requred in each car and at all levels. The button shall be placed in suitable location for acccess of handicapped person. (n) 800 center opening, 2000 mm car height

-

-

-

... More
Supplying, installation, Testing, and commissioning of 15 pasegger (1020 kg) gearless & machine room less lift having superior technology i.e Regen drive, belts, pulse monitoring unit, concealed ceiling with cross flow fan, LCD monochrome display in car and at landings.contract speed of 1.0 MPS serving different floors in the existing lift shaft as per detailed specification as under, complete with modern interior SS Hairline finish, hall buttons, combined with digital CPI on all floors car, operating panel with button and digital CPI suitable for Microprosessor based Simplex collective selective control with /without attandent opreation, top of car inspection box, battrey operated alarm bell, emergency light electronic door detector, elevoice (floor annoucement (system), sills at all landings, header hanger with door frame etc complete as required. (a) Speed 1.0 MPS (b) Floors:- B+G+12 (c) Travel:- B+G+12 (40950mm approximate) (d) Stops & Opening : from 1st door opeing level to last door opeing bottom level.

5

-

-

... More
(e) Controller: Microprosessor based & AC variable voltage & variable ferquency (f) Automatic Rescue Device complete with Dry Maintenance Free Batteries as required . (g) Opration: Microprocessor based Ac variable voltege variable frequency (ACVVVF) controller. Simplex collective selective with /without attendant. (h) Power - 415 Volts, 3 Phase, 50Hz, 4 wire system. (i)Type of doors: (j) Car: Power operated, center opening horizontal sliding stainless steel (Hailine) Stainless Steel false ceiling and granite flooring of approved shade/colour. (k) Landng doors: SS landing doors in Hairline (l)Handrail of sufficiant length at 900 mm above floor level to be fixed in the lift car. (m) Braille operating buttons system as requred in each car and at all levels. The button shall be placed in suitable location for acccess of handicapped person. (n) 900 center opening, 2000 mm car height

-

-

-

... More
Supplying, installation, Testing, and commissioning of 15 pasegger (1020 kg) gearless & machine room less lift having superior technology i.e Regen drive, belts, pulse monitoring unit, concealed ceiling with cross flow fan, LCD monochrome display in car and at landings.contract speed of 1.5 MPS serving different floors in the existing lift shaft as per detailed specification as under, complete with modern interior SS Hairline finish, hall buttons, combined with digital CPI on all floors car, operating panel with button and digital CPI suitable for Microprosessor based Simplex collective selective control with /without attandent opreation, top of car inspection box, battrey operated alarm bell, emergency light electronic door detector, elevoice (floor annoucement (system), sills at all landings, header hanger with door frame etc complete as required. (a) Speed 1.5 MPS (b) Floors:- B+G+11 (c) Travel:- B+G+11 (37800mm approximate) (d) Stops & Opening : from 1st door opeing level to last door opeing bottom level.

2

-

-

... More
(e) Controller: Microprosessor based & AC variable voltage & variable ferquency (f) Automatic Rescue Device complete with Dry Maintenance Free Batteries as required . (g) Opration: Microprocessor based Ac variable voltege variable frequency (ACVVVF) controller. Simplex collective selective with /without attendant. (h) Power - 415 Volts, 3 Phase, 50Hz, 4 wire system. (i)Type of doors: (j) Car: Power operated, center opening horizontal sliding stainless steel (Hailine) Stainless Steel false ceiling and granite flooring of approved shade/colour. (k) Landng doors: SS landing doors in Hairline (l)Handrail of sufficiant length at 900 mm above floor level to be fixed in the lift car. (m) Braille operating buttons system as requred in each car and at all levels. The button shall be placed in suitable location for acccess of handicapped person. (n) 900 center opening, 2000 mm car height

-

-

-

... More
Supplying, installation, Testing, and commissioning of Service lift (1 Tonne) gearless & machine room less lift having superior technology i.e Regen drive, belts, pulse monitoring unit, concealed ceiling with cross flow fan, LCD monochrome display in car and at landings.contract speed of 1.0 MPS serving different floors in the existing lift shaft as per detailed specification as under, complete with modern interior SS Hairline finish, hall buttons, combined with digital CPI on all floors car, operating panel with button and digital CPI suitable for Microprosessor based Simplex collective selective control with /without attandent opreation, top of car inspection box, battrey operated alarm bell, emergency light electronic door detector, elevoice (floor annoucement (system), sills at all landings, header hanger with door frame etc complete as required. (a) Speed 1.0 MPS (b) Floors:- B+G+12 (c) Travel:- B+G+12 (40950 mm approximate) (d) Stops & Opening : from 1st door opeing level to last door opeing bottom level.

3

-

-

... More
(e) Controller: Microprosessor based & AC variable voltage & variable ferquency (f) Automatic Rescue Device complete with Dry Maintenance Free Batteries as required . (g) Opration: Microprocessor based Ac variable voltege variable frequency (ACVVVF) controller. Simplex collective selective with /without attendant. (h) Power - 415 Volts, 3 Phase, 50Hz, 4 wire system. (i)Type of doors: (j) Car: Power operated, center opening horizontal sliding stainless steel (Hailine) Stainless Steel false ceiling and granite flooring of approved shade/colour. (k) Landng doors: SS landing doors in Hairline (l)Handrail of sufficiant length at 900 mm above floor level to be fixed in the lift car. (m) Braille operating buttons system as requred in each car and at all levels. The button shall be placed in suitable location for acccess of handicapped person. (n) 900 center opening, 2000 mm car height

-

-

-

... More
Supplying, installation, Testing, and commissioning of Service lift (1 Tonne) gearless & machine room less lift having superior technology i.e Regen drive, belts, pulse monitoring unit, concealed ceiling with cross flow fan, LCD monochrome display in car and at landings.contract speed of 1.0 MPS serving different floors in the existing lift shaft as per detailed specification as under, complete with modern interior SS Hairline finish, hall buttons, combined with digital CPI on all floors car, operating panel with button and digital CPI suitable for Microprosessor based Simplex collective selective control with /without attandent opreation, top of car inspection box, battrey operated alarm bell, emergency light electronic door detector, elevoice (floor annoucement (system), sills at all landings, header hanger with door frame etc complete as required. (a) Speed 1.0 MPS (b) Floors:- B+G+11 (c) Travel:- B+G+11 (37800 mm approximate) (d) Stops & Opening : from 1st door opeing level to last door opeing bottom level. (d) Stops & Opening : from 1st door opeing level to last door opeing bottom level.

2

-

-

... More
(e) Controller: Microprosessor based & AC variable voltage & variable ferquency (f) Automatic Rescue Device complete with Dry Maintenance Free Batteries as required . (g) Opration: Microprocessor based Ac variable voltege variable frequency (ACVVVF) controller. Simplex collective selective with /without attendant. (h) Power - 415 Volts, 3 Phase, 50Hz, 4 wire system. (i)Type of doors: (j) Car: Power operated, center opening horizontal sliding stainless steel (Hailine) Stainless Steel false ceiling and granite flooring of approved shade/colour. (k) Landng doors: SS landing doors in Hairline (l)Handrail of sufficiant length at 900 mm above floor level to be fixed in the lift car. (m) Braille operating buttons system as requred in each car and at all levels. The button shall be placed in suitable location for acccess of handicapped person. (n) 900 center opening, 2000 mm car height

-

-

-

... More
PART-V : KITCHEN EQUIPMENTS

-

-

-

... More
DISH LANDING TABLE 1350x600x850+150 mm Dish Landing Table with Garbage Chute ( RHS ) : Sunken top of 16 swg 304 ss sheet on 40X40X5 ms angle frame work duly bolted with stud wielding for sturdy and strongest grip & duly rust proof painted on 40x40mm 16swg ss sqaure pipe legs with adjustable bullet feet & 3 sides cross bracingof 25x25mm sqaure pipe. Also provided with a garbage shute.. Entire unit will be in ss 304 grade.

2

-

-

... More
THREE SINK UNIT 1800X600X850+150 (BOWL SIZE -450X450X300 mm) Three sink unit with three side cross brasing, top of 16 SWG Stainless Steel mounted on 40x40x5 s.s angle frame work.Legs made in 40x40 square pipe of 16swg.Cross brasing of 25x25mm sqaure pipe at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade.

2

-

-

... More
GREASE CHAMBER 1200x600x300 mm Unit made in 16swg tank with 5 different partions with sliding top for easy cleaning.one inlet attached to three sink unit.entire unit will be in ss 304 grade

2

-

-

... More
WIPING TABLE W BOTTM PIPE SHELF 1200X600X850+150 mm Wiping table with pipe undershelf, top of 16 SWG Stainless Steel mounted on 40x40x5 m.s angle frame work.Legs made in 40x40 square pipe of 16swg. Lowest shelf of 25x25 mm sqaure pipe of 16swg at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade.

2

-

-

... More
CLEAN DISH RACK -05 TIER 900X450X1800 mm Clean dish rack , shelves made of 18 SWG Stainless Steel sheet.Legs made in 40x40 square pipe of 16swg.unit cointains 5 number of perforated shelves. Lowest shelf at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade.

4

-

-

... More
POT RACK 1200X600X1650 mm Pot rack , shelves made of 25x25mm sqaure pipe.Legs made in 40x40 square pipe of 16swg.unit cointains 3number of pipe shelves. Lowest shelf at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade.

2

-

-

... More
WATER COOLER 150 LTR Make:Bluestar/Voltas/Usha

2

-

-

... More
SS GLASS RACK -05 TIER 600X600X1650 mm SS glass rack , shelves made of 18 SWG Stainless Steel sheet.Legs made in 40x40 square pipe of 16swg.unit cointains 5 number of perforated shelves. Lowest shelf at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade

2

-

-

... More
FOUR DOOR VERTICAL REFRIGERATOR 1200X820X2050 mm Ltr cap:1050.make:-Electolux/Bluestar/Hoshizaki

2

-

-

... More
POTATO PEELER 20 KG Potato peeler.cap 20kg.tank,lid and top made in 16swg ss sheet.frame work of 40x40x5 ms angle frame work.ss shaft use.tank dia:16"and 15"deep.revolving disc madeof 5 mm thick m.s plate.motor make:crompton/godrej of 1.5hp single phase.bottom covering of motor anf frame of 20swg sheet.entire unit will be in ss 304 grade

2

-

-

... More
GRANITE TOP TABLE W THREE SIDE CROSS 1350x600x850 mm Granite top table with three side cross brasing, top of 16mm thick granite mounted on 40x40x5 m.s angle frame work.Legs made in 40x40 square pipe of 16swg.Cross brasing of 25x25mm sqaure pipe at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade

2

-

-

... More
PULVERIZER CAP -2 H.P. MOTOR Pulverlizer : Continuous flow Heavy duty wet grinding with outer covering of ss sheet & feeding hopper of ss base. Fitted with a heavy duty 2 Hp single phase motor. This heavy duty machine can also be used to smash the used particle / food. Provided with blade & detachable ss nets of different sizes for different option.

2

-

-

... More
WALL MOUNTED RACK -02 TIER 2550X300X350 mm wall mounted rack , shelves made of 18 SWG Stainless Steel sheet.Entire unit will be in ss 304 grade.

2

-

-

... More
SINGLE SINK UNIT 600X600X850+150 mm Single sink unit with three side cross brasing, top of 16 SWG Stainless Steel mounted on 40x40x5 s.s angle frame work.Legs made in 40x40 square pipe of 16swg.Cross brasing of 25x25mm sqaure pipe at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade.

2

-

-

... More
GRANITE TOP TABLE W THREE SIDE CROSS 1300X700X850mm Granite top table with three side cross brasing, top of 16mm thick granite mounted on 40x40x5 m.s angle frame work.Legs made in 40x40 square pipe of 16swg.Cross brasing of 25x25mm sqaure pipe at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade

2

-

-

... More
WALL MOUNTED RACK -02 TIER 1300X300X350mm wall mounted rack , shelves made of 18 SWG Stainless Steel sheet.Entire unit will be in ss 304 grade.

2

-

-

... More
DEEP FREEZER 500 LTR Capcity:500 ltr.MAKE:-BLUESTAR/VOLTAS/WESTERN

2

-

-

... More
BUSSING TROLLEY 900X600X850 mm Bussing Trolly : Entire trolly is made of 18 swg 304 ss sheet on ss legs of 40x40mm sqaure pipe with heavy duty castor wheels. Provided with a bottom shelf with a push cart type handle. Entire unit in ss 304 grade

2

-

-

... More
STORAGE RACK 900X450X1800 mm Storage rack , shelves made of 18 SWG Stainless Steel sheet.Legs made in 40x40 square pipe of 16swg.unit cointains 5 number of shelves. Lowest shelf at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade.

6

-

-

... More
PALLETS 1500X350X150 mm Pallets , top made of 25x25mm sqaure pipe.Legs made in 40x40 square pipe of 16swg. Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade.

4

-

-

... More
STOCK POT 600X600X600 mm Low height burner with four side cross brasing, top of 16 SWG Stainless Steel mounted on 40x40x5 m.s angle frame work.Legs made in 40x40 square pipe of 16swg.Cross brasing of 25x25mm sqaure pipe at height of 6". Adjustable bullet feets fitted into all four legs.Heavy duty cast iron pan support of 16"x16".Gas piping and fitting of make:SARNA/HPC/UNITED. Entire unit will be in ss 304 grade

8

-

-

... More
LOW HEIGHT TABLE 600X600X600 mm Low height table with four side cross brasing, top of 16 SWG Stainless Steel mounted on 40x40x5 m.s angle frame work.Legs made in 40x40 square pipe of 16swg.Cross brasing of 25x25mm sqaure pipe at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade

2

-

-

... More
SS EXHAUST HOOD 1950X750X500 mm HOOD MADE WITH 20/22 SWG SHEET 202 GRADE.WITH FILTERS 20"X20".WITH LED TUBES FITTED

4

-

-

... More
WORK TABLE W 02 US 1500X600X850 mm Working table with 2 undershelves, top of 16 SWG Stainless Steel mounted on 40x40x5 m.s angle frame work.Legs made in 40x40 square pipe of 16swg. Lowest shelf of 18swg at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade

4

-

-

... More
ROLLING TABLE W 02 US WITH GRANITE TOP 1500X600X850 mm Granite top table with 2 under shelves, top of 16mm thick granite mounted on 40x40x5 m.s angle frame work.Legs made in 40x40 square pipe of 16swg. Lowest shelf of 18swg at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade.

2

-

-

... More
CHAPATTI CUM PUFFER 1500X600X850 mm Chapati plate with puffer with one undershelf ,hot plate made of 20mm thick m.s polished plate mounted on 40x40x5 m.s angle frame work.48" hot plate and 12" puffer.Legs made in 40x40 square pipe of 16swg.Bottom shelf of 18swg at height of 6". Adjustable bullet feets fitted into all four legs.Heavy duty cast iron puffers support of 12"x12".Gas piping and fitting of make:SARNA/HPC/UNITED. Entire unit will be in ss 304 grade

2

-

-

... More
SS EXHAUST HOOD 1650X750X500 mm HOOD MADE WITH 20/22 SWG SHEET 202 GRADE.WITH FILTERS 20"X20".WITH LED TUBES FITTED

2

-

-

... More
CHAPATTI COLLECTION TROLLEY 900X600X850 mm Chapati collection Trolly : Entire trolly is made of 18 swg 304 ss sheet on ss legs of 40x40mm sqaure pipe with heavy duty castor wheels. Provided with a bottom shelf with a push cart type handle. Entire unit in ss 304 grade

2

-

-

... More
HOT AND AMBIENT BAIN MARIE W 01 US 1800X700X850 mm Double vault mineral wool insulated.all s.s body on tiny legs. The top made in 16swg ss is divided in 2 parts:-a.one to hold 4 no. gn pans of 1/1 for hot food and another one to hold 2 gn pans of 1/2 for cold/ambient food. The hot compartment to have 2 no.of emmersion type element of 1.5kw each with auto temp.controller and indicating lamps.tank made in 18swg. The entire unit is three side covered with 20swg ss sheet and under shelf beneath of 18swg.entire unit will be in ss 304 grade

2

-

-

... More
WORK TABLE W 02 US 850X700X850 mm Working table with 2 undershelves, top of 16 SWG Stainless Steel mounted on 40x40x5 m.s angle frame work.Legs made in 40x40 square pipe of 16swg. Lowest shelf of 18swg at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade

2

-

-

... More
CROCKERY TABLE W 02 US 900X600X850+150 mm Crockery table with 2 undershelves, top of 16 SWG Stainless Steel mounted on 40x40x5 m.s angle frame work.Legs made in 40x40 square pipe of 16swg. Lowest shelf of 18swg at height of 6". Adjustable bullet feets fitted into all four legs. Entire unit will be in ss 304 grade

4

-

-

... More
TEA CONTAINER 25 LTR

2

-

-

... More
PART-W : IBMS WORKS

-

-

-

... More
Software and Operator Workstation Supply, installation, testing and commissioning of I7 Processor or Equivalet PC with 4 GB RAM, & 1 TB HDD, 10/100 Mbps Ethernet card, USB connection & internal modem, Microsoft(R) Windows(R) 7 OS Professional or higher. Accessories included Optical Mouse, Key Pad, Laserjet colour A4 printer with the above BMS System configuration.

1

-

-

... More
a) 32 Inch HD Color LED Monitor.

1

-

-

... More
b) Laser jet Printer (A4 size, B&W)

1

-

-

... More
Supply, installation, testing and commissioning of Layer 2/3 managed switch with 16 or 24 ports (RJ-45) port. The switch shall have 2 RSTP enabled ports to communicate with other switches to built a ring topology network on CAT6 A cable. The switch shall have 1 GB port to communicate with other switches including Passive components inbuilt 2 SFP ports including SFP modules, rack mountable, SMPS power supply & other termination accessories (Like Pigtails/LIUs/ Convertors/Splicing equipment, Patch panel, Patch Cord, Etc) complete as per specifications and as required for BMS DDC Panel Networking. The switch to switch distance shall not exceed beyond 80 meters. Vendor to decide the quantity of network switches based on their network design.

1

-

-

... More
BUILDING MANAGEMENT SYSTEM WEB-BASED SERVER SOFTWARE Supply, Installation, Testing & Commissioning of software for Building Management Software with features like 3D vector dynamic graphics with Autocad import of plan with Zoom In & Zoom Out facility, Graphic Builder, Plant Viewer, Trend Viewer, Object Viewer, Report Viewer, Alarm router, Log Viewer. The Web-Based Server software shall permit use of Standard Web-Browsers such as Microsoft Internet Explorer, Netscape Navigator, etc. The software shall be capable of integartion third-party systems and should supports latest IP technology (IP V4/V6). The Management Stations shall match the BACnet Profile B-AWS (Advanced workstation) as per the BTL Listing. The Web based software shall include 1 Client License for remote viewing. Number of IO points shall be considered as per the IO summary considering 15% spares.

1

-

-

... More
PROGRAMMABLE & APPLICATION SPECIFIC CONTROLLER (DDC) - UL LISTED/BTL certified. Supply, Installation, Testing & Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed & UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port & shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending & scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. (Make:- Siemens/Schneider StructureWare/Honeywell Trends) The above shall be housed in IP 55 vandal proof, lockable & secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 10% for future expansion. a) HVAC & Ventilation system

-

-

-

... More
i) DDC for Chilled Plant Manager includes Chiller, Primary, Secondary, Hot Water Generator, Hot Water Generator Pumps

1

-

-

... More
ii) DDC for Air Handling Units/CSU (Max 1 AHU per DDC)

9

-

-

... More
iii) DDC for Liftwell/Staircase Pressurization/Fresh Air/ Exhaust Fans

35

-

-

... More
iv) DDC for Air Washer & Scrubber Units (Max 1 unit per DDC)

13

-

-

... More
SYSTEM INTEGRATION UNITS for 3rd party integartions - UL listed Controllers & BTL label Supply, Installation, Testing & Commissioning of True IP Based System Integration unit consisting of microprocessor based controller units BTL & UL Listed for third party integration. The same should support operations/ monitoring via portable operator terminal. .The controller shall be Native BACnet type with communication via BACnet/LonTalk, Integration platforms and system controllers for third-party devices and systems via KNX, Modbus, M-Bus and other protocols into the automation level via BACnet. The same shall Support operation via local or network-compatible operator units. It should store trend logs and event buffer for a typical duration of up to 30 Days. All the Integrators shall be seperate. Note: No 3rd party make integartor shall be accepted.

-

-

-

... More
i) Chillers Integartion on Modbus Protocol - 10 Points per Chiller

1

-

-

... More
ii) VFD Integration of Sec. Pumps - 10 Points per VFD

1

-

-

... More
iii) AHUs VFD Integartion on Modbus RTU with RS 485 Communication Port - 10 Points per VFD

1

-

-

... More
Field instruments Supplying, installing, testing and commissioning of the following sensors / transducers / transmitters.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Immersion temperature sensor 100 mm Pt1000 with Brass Thermowell.

8

-

-

... More
Supply, Installation, Testing & Commissioning of Outside air temperature + humidity sensors for measuring outside air temperature. It should be provided with sun sheild and rain protection.

1

-

-

... More
Supply, Installation, Testing & Commissioning of In line Type Electromagnetic Water Flow Meter - Dia Size 350 mm

1

-

-

... More
Supply, Installation, Testing & Commissioning of Differential Pressure Switch Water

6

-

-

... More
Supply, Installation, Testing & Commissioning of Current Relay

2

-

-

... More
Supply, Installation, Testing & Commissioning of Differential pressure switch for Blower Status (Pa Range 50…300 Pa)

9

-

-

... More
Supply, Installation, Testing & Commissioning of Differential pressure switch Filter Status (Pa Range 50...500 Pa)

9

-

-

... More
Supply, Installation, Testing & Commissioning of Duct sensor for humidity

22

-

-

... More
Cabling and Conduiting

-

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. (2 core x 1 Sq.mm), PVC insulated, Shielded tinned copper conductor cable.

18000

-

-

... More
Supplying, laying, termination, testing & commissioning of CAT 6A unarmoured Cables with required accessories like RJ45 connector etc.

5000

-

-

... More
Supplying, laying, termination, testing & commissioning of 2 core fibre Optical cable, zero halogen low smoke outer sheath with required junction boxes connectors and jointing accessories.

2000

-

-

... More
Supply, Installation, Testing & Commissioning of MS Conduit 25 mm for Signal & Communication Cable.

18000

-

-

... More
Supply, Installation, Testing & Commissioning of GI Flexible Conduit 25 mm.

2000

-

-

... More
Credit

-

-

-

... More
Credit for hard rock obtained under item No. 1.04

2117

-

-

... More
Credit for Steel work

5490

-

-

... More
Credit for Bricks obtained under item No. 12.04

215510

-

-

... More
Credit of stone from rubble masonry obtained under item No. 12.05

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.