Council Of Scientific And Industrial Research Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Council Of Scientific And Industrial Research - CSIR Tender

Works
Electrical and Electronics
Eprocure
Opening Date29 Jan 2025
Closing Soon7 Feb 2025
Tender Amount₹ 1,63,26,556 
Notes
Download

Costs

Summary

Agmc Of Sub Station Panel Internal Electrification Work Electrical And Associated System Including Operation Of Dg Sets Water Pumps And Lifts Installed At Csir Hq Csir Complex Csir Mbsa New Delhi

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Schedule B :- CSIR complex and Guest House

-

-

-

... More
Sub-Head- I :- Operation, Preventive and Routine Maintenance of Electrical Systems

-

-

-

... More
Operation and Maintenance (Routine/ Preventive/breakdown) of entire Electrical Installation including Distribution boards, LT panels, operation of various DG sets, substation, waterpumps, lifts and Comprehensive Maintenance of 300 KVAR capacitor bank at CSIR Complex, New Delhi. The scope of work including the deployment of manpower is as per Annexure -I

12

-

-

... More
Schedule C :- MBSA and IPU at NIScPAR

-

-

-

... More
Sub-Head- I :- Operation, Preventive and Routine Maintenance of Electrical Systems

-

-

-

... More
Operation and Maintenance (Routine/ Preventive/breakdown) of entire Electrical Installation including distribution boards, LT panels, operation of various DG sets, waterpumps, lifts and Comprehensive Maintenance of 100 KVAR capacitor bank at CSIR MBSA, New Delhi and IPU at NIScPR building , satsang Vihar, New Delhi. The scope of work including the deployment of manpower is as per Annexure -I

12

-

-

... More
Sub-Head - II :- Replacement of Electrical Components & Accessories

-

-

-

... More
Replacement of Defective of following rating and breaking capacity and pole MCCB including supply with thermomagnetic Release and terminal spreaders in existing cubicle panel board drilling connections etc as required.

-

-

-

... More
100 A, 16 KA TPMCCB

3

-

-

... More
125 A, 16KA TPMCCB

2

-

-

... More
200 A, 25KA TPMCCB

2

-

-

... More
125 A, 36 KA FPMCCB

2

-

-

... More
200 A, 36 KA 4 pole MCCB

3

-

-

... More
250 A, 36 KA 4 pole MCCB

3

-

-

... More
250 A, 25 KA 4 pole MCCB

1

-

-

... More
400 A, 50 KA 4 pole MCCB

1

-

-

... More
Replacement of defective 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker including supply suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

65

-

-

... More
Single pole and neutral

60

-

-

... More
Triple pole

4

-

-

... More
Triple pole and neutral

4

-

-

... More
Replacement of defective 63 amps rating, 240/415 volt "C" series, miniature circuit breaker including supply suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing & commissioning etc. as required.

-

-

-

... More
Single pole and neutral

6

-

-

... More
Triple pole and neutral

4

-

-

... More
Replacement of defective Fan regulator on existing switch box cover including supply and connections etc complete in all respect. Switch type fan regulator of "Anchor" / "Rider make 100 Watt 230 volts

43

-

-

... More
SITC of hand dryer of 1200 Watt, 50 Hz, 230 Volts, 30 dB, stainless steel body with connections, acessories including supply etc complete as required. Make: Kopal

8

-

-

... More
Replacement of defective exhaust fan of 300 mm sweep, single phase, 900/1400 RPM complete with all accessories including supply, connections etc complete in all respect.

19

-

-

... More
Replacement of defective heavy duty exhaust fan of 450 mm sweep, single phase, 900/1400 RPM complete with all accessories including supply, connections etc complete in all respect.

1

-

-

... More
Replacement of defective starter including supplying etc complete in all respect.

20

-

-

... More
Replacement of defective capacitor 2.5 Mfd, 230 V A.C. including supply in the existing fitting / fans etc complete in all respect.

75

-

-

... More
Replacement of defective Plug Top including supply, connections etc. as required.

-

-

-

... More
3 pin Top 6 Amp

35

-

-

... More
3 pin Top 16 Amp

35

-

-

... More
Replacement of defective flexible 3 core 2.5 sq.mm. copper PVC insulated unarmoured round cable 1.1 KV grade including supply,connection etc as required.

75

-

-

... More
Replacement of defective 9 watt LED bulb, 230V, AC, including supply etc as req.

40

-

-

... More
Replacement of defective Remote Bell including supply and connection etc as req. "Cona" Make

7

-

-

... More
Replacement of defective electronic ballast Choke with connector of 36/40 W FT including supply etc complete as required.

10

-

-

... More
Replacement of defective Ceiling fan with 1200 mm sweep blades, high speed including supply making connections and accessories etc. complete as required.

15

-

-

... More
Replacement of defective wall mounting fan with regulator of 400 mm sweep with oscilation on wall / wood with the help of rawl plug and screws including supply and connections etc complete in all respect.

25

-

-

... More
Replacement of defective Recess mounted round LED downlighter of 5W or above (for lift Car )with all required drivers, hook, chain other related accessories including SITC etc. complete in all respect.

6

-

-

... More
Replacement of defective 20 Watt or above LED Batten ( Cool Day Light 6500K) 240 V, Fitting including SITC LED fitting on surface / recessed with all acessories etc complete in all respect.

80

-

-

... More
Replacement of defective hylum sheet 3 mm thick including supply in the existing switch / socket MS box etc complete in all respect.

2750

-

-

... More
Supplying and fixing of 6 module plastic box horizantal with modular plate and cover on surface or in recess, including providing and fixing 1 number 16 amp modular switch, 2 number 16 amp modular Socket and 1 number blank plate including connections etc as required.

25

-

-

... More
Replacement of 32 A, 240V (white) D.P. Main Switch Operating with Key Tag 2 Make - ROMA including supply and connection etc complete as required

20

-

-

... More
Supplying and fixing 8 module plastic box horizontal with modular plate and cover on surface or in recess, including providing and fixing 1 number 6 amp modular switch, 3 number 6 amp modular Socket and 1 number blank plate including connections etc as required.

60

-

-

... More
Providing and fixing following size of PVC casing and caping on surface as required.

-

-

-

... More
(a) 25mm x16mm

300

-

-

... More
(b) 38mm x16mm

45

-

-

... More
Illumination of Building on rental Basis for foundation day / independence day / any occasion as per instruction by Engineer-in-Charge with suitable LED lights for decoration of the campus for two days including man power, material, transportation etc. complete as required at CSIR HQ, Rafi Marg, New Delhi. (a) Providing and fixing weather proof required number of coloured 100 Watt or above LED flood lights (Qty 80 Nos or above as per requirment) in three/Tri colours i.e, orange/amber, white and green with a building length of 45 meter horizontally and 12 meter vertically. (b) Providing and fixing weather proof LED strip lighting in three colours i.e, orange/amber, white and green on terrace with a parapet length of 25 mts and in vertical lines of 15 meters drop at every interval of 0.25 m. (c) Providing and fixing weather proof LED strip lighting on terrace with a parapet length of 60 mts. (d) Illuminating the porch area of the building in vertical lines of 5.0 m drop at every interval of 0.25 mts. (e) Illuminating the Boundary wall of 60 mts length and 2 nos. gates including security room area. (f) Illumination of 25 nos. trees and plants, fountain area in lawn (g) Illumination of 13 numbers round pillars of dia 0.5 mtr, height 3.5 mtr weather proof LED strip lighting in three colours i.e, orange/amber, white and green as per the instruction of Engineer-In- charge. (CSIR-HQ)

1

-

-

... More
Illumination of Building on rental Basis for foundation day / independence day / any occasion as per instruction by Engineer-in-Charge with suitable LED lights for decoration of the campus for two days including man power, material, transportation etc. complete as required at CSIR HQ, Rafi Marg, New Delhi. (a) Providing and fixing weather proof required number of LED PAR lights (Qty 150 Nos or above as per requirement along with the sutaible size stand ) of sutable wattage 180 watt or above in three/Tri colours i.e, orange/amber, white and green with a building length of 45 meter horizontally and 12 meter vertically. (b) Providing and fixing weather proof LED strip lighting in three colours i.e, orange/amber, white and green on terrace with a parapet length of 25 mts and in vertical lines of 15 meters drop at every interval of 0.25 m. (c) Providing and fixing weather proof LED strip lighting on terrace with a parapet length of 60 mts. (d) Illuminating the porch area of the building in vertical lines of 5.0 m dropat every interval of 0.25 mts. (e) Illuminating the Boundary wall of 60 mts length and 2 nos. gates including security room area. (f) Illumination of 25 nos. trees and plants, fountain area in lawn (g) Illumination of 13 numbers round pillars of dia 0.5 mtr, height 3.5 mtr weather proof LED strip lighting in three colours i.e, orange/amber, white and green as per the instruction of Engineer-In- charge. (CSIR-HQ)

2

-

-

... More
Illumination of Building on rental Basis for foundation day / independence day / any occasion as per instruction by Engineer-in-Charge with suitable LED lights for decoration of the campus for two days including man power, material, transportation etc. complete as required at CSIR Complex, Pusa, New Delhi. (a) Providing and fixing weather proof of coloured LED IMPRESSION PAR lights in 160-180 nos.of suitable wattage 180 watt or above in three/Tri colours i.e. orange/amber, white and green including required number of Rack and stand for main building with a horizontal length of 30 meter , 20 meter (annexe building), 50 meter (Guest House) and vertical length of 28 Mtr drop (MB), 10 m drop (Annexe and GH building), connection etc as required(One Job for independence day and One job for foundation day)as per the instruction of Engineer-In- charge. b) Illuminating the porch area with Providing and fixing weather proof LED strip (fixed) lighting in three colours i.e. orange/amber, white and green on connecting corridor at first floor from main building to annexe building with a parapet length of 25 meter (connecting corridor) and in vertical lines of 3 Mtr drop at every interval of 0.25 Mtr . (c ) illumination of plantations near guest house only (d) Illuminating of 2 nos. gates including security room area. (CSIR-CX)

2

-

-

... More
Replacement of defective Post top LED luminaire of 35 W or above Light Fitting on the existing 50 mm dia GI poles with the help of GI reducer/GI nipple with all required drivers including supply, fixing and connection etc complete in all respect. Make:- Havells Cat No RUBYPT35WLED757PSYMTOPC / Philips equivalent as per approved list of makes.

3

-

-

... More
Replacement of defective 100 Watt Cool Day White Square LED Flood Light for existing GI pole / Sign Board, IP: 65/66, 230 V, 50 Hz including SITC etc complete as required.

5

-

-

... More
Replacement of defective of Recess LED light fitting 6500K, 30W or above, 2'x2' luminaire having CRCA housing with all required drivers, hook, chain other related accessories including repair & alternation in ceiling plan for fixation of LED fittings and dismanteling of existing wall bracket / ceiling fittings / fluorescent fitting including supply, testing and commissioning etc. complete in all respect.

50

-

-

... More
Replacement of defective Recess mounted LED light fitting 6500K, 30W or above, 4'x1' luminaire with all required drivers hook, chain other related accessories including repair & alternation in ceiling plan for fixation of LED fittings and dismanteling of existing wall bracket / ceiling fittings / fluorescent fitting including supply, testing and commissioning etc.complete in all respect.

9

-

-

... More
Replacement of defective of Recess mounted round LED downlighter 6500K, 12W or above with all required drivers other related accessories including supply, testing and commissioning etc. complete in all respect.

16

-

-

... More
Replacement of defective Surface mounted round LED downlighter in aluminum die cast body of 12 W or above 6500K , with all required drivers including SITC etc complete in all respect.

52

-

-

... More
Replacement of wireless dimmable Recess mounted Direct/ Indirect LED 2'x2' luminaire in the range of 6500K, 30w or above with all required drivers, hook, chain other related accessories including supply, repair & alternation in ceiling plan for fixation of LED fittings and dismanteling of existing wall bracket / ceiling fittings / fluorescent fitting complete in all respect, with wireless controller

2

-

-

... More
Replacement of LED Street Light Luminaire of 6500K, 35 W or above & the luminaire shall be with all required drivers, hook, chain other related accessories including supply, repair & alternation in the fixation of LED fittings and dismanteling of existing fitting complete in all respect.

5

-

-

... More
Supplying and fixing of LED strip in required colour including driver, adapter, connections etc complete as required.

25

-

-

... More
Replacement of defective flexible 3 core 4.0 sq.mm. copper PVC insulated unarmoured round cable 1.1 KV grade including supply,connection etc as required.

100

-

-

... More
Supplying, installation, testing and commissioning of 100 Watt tricolour LED Flood Light for existing GI pole / Sign Board, IP: 65, 230 V, 50 Hz etc complete as required.

12

-

-

... More
Replacement of defective following LED driver with connector of LED Light fitting including supply etc complete as required.

-

-

-

... More
LED driver, V(out): 30-36 VDC, I(out): 0.900 A, P(out): 33 W for 4'x1' luminaire

25

-

-

... More
LED driver, V(out): 53 VDC, I(out): 0.720 A, P(out): 40 W for 2'x2' luminaire

15

-

-

... More
LED driver, V(out): 30-40 VDC, I(out): 0.900 A, P(out): 32 W for 2'x2' luminaire

10

-

-

... More
LED driver, V(out): 145 VDC, I(out): 0.230 A, P(out): 36 W for 2'x2' luminaire

10

-

-

... More
LED driver, V(out): 40 VDC, I(out): 0.250 A, P(out): 7 W for bolard light luminaire

1

-

-

... More
LED driver, V(out): 30-38 VDC, I(out): 0.860 A, P(out): 25-35 W for Street light luminaire

1

-

-

... More
LED driver, V(out): 32-54 VDC, I(out): 1.4 A, P(out): 75 W for Street light luminaire

1

-

-

... More
LED driver, V(out): 107-214 VDC, I(out): 0.700 A, P(out): 150 W for Flood light luminaire

1

-

-

... More
LED driver, V(out): 60-74 VDC, I(out): 0.950 A, P(out): 75 W for Flood light luminaire

1

-

-

... More
LED driver alongwith blutooth dimmer controler V(out): 24-40 VDC, I(out): 1800 mA, P(out): 44 W or above for 4'x1' luminaire

1

-

-

... More
Replacement of defective LED Indicator with different colours 230 Volts, 50 Hz with connections, acessories including supply etc complete as required.

10

-

-

... More
Replacement of defective door locks for LT Panels/DB including supply etc complete as required.

10

-

-

... More
Replacement of defective 18 watt or above LED bulbs , 230V, AC, including supply etc as req.

20

-

-

... More
S/I/T/C of "KSB" Make 1.5 KW / 2 HP Submersible Sewage Pump KSTP 20, Single Phase, 50 Hz, 220 V, Pipe size 50 mm etc complete as required

1

-

-

... More
Supplying of 4C x 16 sq mm Aluminium Conductor Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade conforming to IS: 7098 ( Part-1) with latest amendments etc complete as required.

75

-

-

... More
Supplying of 4C x 50 sq mm Aluminium Conductor Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade conforming to IS: 7098 ( Part-1) with latest amendments etc complete as required.

75

-

-

... More
Filtration & dehydration of Outdoor/indoor type 440V, 3 Phase, 750 KVA Servo-Stabilizer Transformer (Oil Capacity 2000 liters) Oil streamlined filter machine, attending the leaking point, replacement of packing gasket, bushing rods, including supply and top-up with transformer oil with low viscosity EHV grade in the main transformer tank upto the required level, dis-connection and re-connection of cables and painting with synthetic enamel paint (2 or more coat with spray machine with existing colour maching paint including scrapping, rubbing of old paint with sand paper, applied deco putty (where required) on the surface etc complete as required.

1

-

-

... More
Supplying, installation, testing and commissioning of single phase 1 HP, sump pump with starter in Basement of Fire Pump House with required Drain Pipe I/c connection, inter connections …etc . Complete in all respect.

1

-

-

... More
Supplying and fixing 3 module water proof box with enclosure on surface or in recess, including providing and fixing 1 number 20 A modular switch, 1 number 16 A modular Socket including connections etc as required.

1

-

-

... More
S/I/T/C 7.5 HP horizontal Openwell Submersible water Pump- Motor, Three Phase, 50Hz, copper winding of suitable discharge range with minimum head range of 50 m including incoming & outgoing pipe connectios etc complete as required. (Make: Kirloskar / Crompton)

1

-

-

... More
Replacement of defective LED driver/Controller with V(in): 220-240 VAC Freqency: 50 Hz,0.6 A IP20 tc : 70 Degree celsius ta : -20.....50 Degree celsius along with connector for dimmable light fitting f Wipro make CAT no. LM38-461-xxx-65-xx including supply etc complete as required by the respective OEM/ Wipro.

10

-

-

... More
Supplying and drawing 3x10 sq.mm sizes of FR PVC insulated copper conductor, single core cable in the existing surface / recessed PVC / Steel conduit / PVC casing and capping as required.

20

-

-

... More
Replacement of defective L&T make D-O-L starter, Relay range 11-18 ampere, three phase, 440 V, 50 Hz including SITC of starter, incoming and outgoing cable connections etc complete as required

2

-

-

... More
Replacement of defective 25 litre vertical water geyser 4/5 star including supplying 25 L Vertical water geyser, 230 V, 50 Hz etc complete in all respect

4

-

-

... More
Sub-Head - III Internal Electrification Work.

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C

20

-

-

... More
Rewiring for Light point / Fan point Exhaust fan point / Call bell point with 1.5 sq. mm. FR PVC insulated, copper conductor cable and 1.5 sqmm FR PVC insulated copper conductor single core cable as earth wire in the existing surface / recessed steel / PVC conduit including dismantling as required.

-

-

-

... More
Group A

30

-

-

... More
Group c

8

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2x 2.5 sqmm + 1 x 2.5 sq. mm earth wire

70

-

-

... More
2x 4 sqmm + 1 x 4 sq. mm earth wire

30

-

-

... More
2x 6 sqmm + 1 x 6 sq. mm earth wire

60

-

-

... More
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface / recessed PVC / Steel conduit / PVC casing and capping as required.

-

-

-

... More
2 x1.5 sq. mm

160

-

-

... More
3 x1.5 sq. mm

325

-

-

... More
3 x 2.5 sq. mm

550

-

-

... More
3 x 4 sq. mm

400

-

-

... More
2 x 6 sq.mm

20

-

-

... More
3 x 6 sq. mm

150

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

70

-

-

... More
25 mm

300

-

-

... More
Supplying and fixing following piano type switch/socket on the existing switch box / cover including connections etc. as required.

-

-

-

... More
5/6 amp switch

260

-

-

... More
15/16 amp switch

60

-

-

... More
3 pin 5/6 amp socket outlet

60

-

-

... More
6 pin 15/16 amp socket outlet

40

-

-

... More
2 way 5/6 amp switch

10

-

-

... More
Bell push

12

-

-

... More
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required

-

-

-

... More
5/6 amp switch

55

-

-

... More
15/16 amp switch

55

-

-

... More
3 pin 5/6 amp socket outlet

40

-

-

... More
6 pin 15/16 amp socket outlet

40

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

5

-

-

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
1 or 2 Module

7

-

-

... More
3 Module

7

-

-

... More
4 Module

4

-

-

... More
6 Module

12

-

-

... More
8 Module

10

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch, connections, painting etc. as required.

25

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5pin 15 /16 amps modular socket outlet and 15 / 16 amps modular switch, connections, painting etc. as required.

35

-

-

... More
Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.

30

-

-

... More
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.

35

-

-

... More
Supplying and fixing PVC batten/ angle holder including connections etc. as required.

78

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

17

-

-

... More
Supplying and fixing metal box of following sizes (nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required

-

-

-

... More
100mm x 100mm x 60mm deep

30

-

-

... More
150mm x 75mm x 60 mm deep

25

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of aa sizes.

10

-

-

... More
Replacement of defective DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB including supply complete with connections, testing and commissioning etc. as required.

25

-

-

... More
Providing and fixing of 25 mm x 5 mm GI Earth strip on surface or in-recess for connections etc. as required.

20

-

-

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box including connections etc. As required

10

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

35

-

-

... More
Supplying and installing following size of perforated painted with powder coating M.S. Cable trays with perforation not morethan 17.5 %, in convenient sections, joined with connector, suspended from the ceiling with M.S. Suspenders including bolts and nuts, painting suspenders etc. as required (a) 450 mm width x 50 mm depth x 2 mm thickness

20

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(2 neutral earthing of Transformer.)

4

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size above 185 sq.mm and upto 400 sq.mm C clamped with 40x3 mm MS flat clamp) on wall surface as required.

-

-

-

... More
Upto 35 sqmm (clamped with 1 mm thick saddle)

75

-

-

... More
Above 35 sq.mm and upto 95 sq.mm (clamped with 25x3 mm MS flat clamp)

75

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 x 16 sq mm (28 mm)

2

-

-

... More
4 x 50 Sq mm (35 mm)

2

-

-

... More
Lifting of AC LT Panel about 300 mm height from the existing base including dismantling of exisitng cables and panel, reinstallation of panel connections etc. complete as required.

1

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

35

-

-

... More
Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

1.6

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
a) 3.5 x 240 Sq.mm

1

-

-

... More
b) 3.5 x 120 Sq.mm

5

-

-

... More
c) 3.5 x 35 Sq.mm

5

-

-

... More
d) 3.5 x 25 Sq.mm

2

-

-

... More
Supplying, installation, testing and commissioning of 1250 Amp, 4 pole on-load changeover switch model: IHCNFO1250, make: Havells as per manufaturer specifications including connections etc complete as required.

1

-

-

... More
Providing and laying of electrical insulating synthetic mat of high electrical insulation resistance, 100% shock proof, under leakage current 10 mA, fire retardant, high durability, high tensile strength & elongation properties, ageing properties etc. as per relevant IS:15652:2006, tested for break down voltage, moisture proof, having no effect of acid, alkaline diesel & transformer oil, washable, suitable for both DC & AC electrical installations etc complete as required. (Mat Make - TRIMAT)

-

-

-

... More
a) 2.0 mm thick, class A, AC Voltage (0-3.3 KV)

75

-

-

... More
Providing & fixing of gel earthing system of dual pipe technology made of copper Pipe-1) Medium duty of following sizes as per points mentioned (a), (b), (c), (d) below :- (a) Filled with anti-corrosive conductive compounds with the permanent sealing at both the ends, CPRI / ERDA tested with RMS capacity of minimum 35-40 KA for withstanding 1second 25kg for 2000mm & 50Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL accredited lab & high conductivity in nature with carbon as a major content. (b) Heavy duty weather proof poly-propylene earth pit chamber of size: Top Dia. 225 to 260 mm, bottom dia. 300 to 350 mm and height 250 to 300 mm. (c) Testing of earth resistance for value of 1 Ohms or less as required (d) Self certificate for confirming above standards from OEM is mandatory. All as approved by Engineer-in-charge. , copper pipe3000 mm long, 80/50mm, Terminal 50mmx6mm Copper Strip etc. complete as required.

6

-

-

... More
Sub - Head IV :- Repairing, Servicing and Rewinding of Fans, Pumps and Motors.

-

-

-

... More
Repairing and over hauling of Ceiling fans up to 56" sweep including repairing of shaft, disconnecting and reinstallation of the same complete in all respect.

-

-

-

... More
Rewinding of Motor with enamelled copper wire

20

-

-

... More
Replacement of Bearings / bush.

25

-

-

... More
Repairing and over hauling of Exhaust Fan up to 18" sweep including repairing of shaft, disconnecting and reinstallation of the same complete in all respect.

-

-

-

... More
Rewinding of Motor with enamelled copper wire

20

-

-

... More
Replacement of Bearings / bush.

20

-

-

... More
Repairing and overhauling of Wall Mounting Fan up to 400 mm sweep including all materials, disconnecting and reinstallation of the same complete as required.

-

-

-

... More
Rewinding of Motor with enamelled copper wire

2

-

-

... More
Replacement of Bearings / bush.

2

-

-

... More
Repairing, over hauling & rewinding of 1 HP Submersible (Sewage) Pump including reinstallation, lowering the same after replacement of gun metal bushes,bearing,waterseal, bearing, plate impeller,sleeves etc. complete in all respect.

4

-

-

... More
Repairing and over hauling of 1 Phase ,1 HP Monoblock Pump Motor including replacement of water seal, rusted nut & bolts, repairing of shaft etc. after disconnecting and reinstallation of the same complete in all respect.

-

-

-

... More
Rewinding of Motor with enamelled copper wire

2

-

-

... More
Replacement of Bearings

2

-

-

... More
Replacement of Impeller.

2

-

-

... More
Repairing and over hauling of 7.5 HP Monoblock Pump Motor including replacement of water seal, rusted nut & bolts repairing of shaft etc. after disconnecting and reinstallation of the same complete in all respect.

-

-

-

... More
Rewinding of Motor with enamelled copper wire

2

-

-

... More
Replacement of Bearings

2

-

-

... More
Replacement of Impeller.

2

-

-

... More
Repairing and over hauling of 15 HP Monoblock Pump Motor including replacement of water seal, rusted nut & bolts repairing of shaft etc. after disconnecting and reinstallation of the same complete in all respect.

-

-

-

... More
Rewinding of Motor with enamelled copper

1

-

-

... More
Replacement of Bearings

2

-

-

... More
Replacement of Impeller.

1

-

-

... More
Repairing of 1 HP, 1 phase, 50 Hz Submersible pump including replacement of gun metal bushes, waterseal,thrust bearing plate impeller, sleeves etc. complete in all respect.

1

-

-

... More
Rewinding of 1 HP , 1 Phase 50 Hz Submersible motor with water proofing copper wire of apporpriate size and complete overhauling of motor, replacement of all necessary spare required or smooth functioning of submersible motor etc complete in all respect.

1

-

-

... More
Lifting and lowering of 1 HP ,1 phase ,50 HZ Submersible Pump-Motor in existing bore well etc. complete in all respect.

1

-

-

... More
Repairing of 5 HP, 25 stage, 3 Phase Submersible Pump including replacement of gun metal bushes, waterseal,thrust bearing plate impeller, sleeves etc. complete in all respect.

2

-

-

... More
Rewinding of 5 HP ,25 stage, 3 Phase Submersible Motor with water proofing copper wire of apporpriate size and complete overhauling of motor, replacement of all necessary spare required or smooth functioning of submersible motor etc complete in all respect.

2

-

-

... More
Lifting and lowering of 5 HP 25 stage ,3 phase Submersible Pump-Motor in existing bore well etc. complete in all respect.

2

-

-

... More
Repairing of 7.5 HP, 3 Phase Submersible Pump including replacement of gun metal bushes, waterseal,thrust bearing plate impeller, sleeves etc. complete in all respect.

1

-

-

... More
Rewinding of 7.5 HP, 3 Phase Submersible Motor with water proofing copper wire of apporpriate size and complete overhauling of motor, replacement of all necessary spare required or smooth functioning of submersible motor etc complete in all respect.

2

-

-

... More
Lifting and lowering of 7.5 HP, 3 phase Submersible Pump-Motor in existing bore well etc. complete in all respect.

1

-

-

... More
Rewinding, repairing and over hauling of 7.5 HP Openwell Submersible Pump- Motor including lifting, lowering, replacement of water seal, rusted nut & bolts, bearing etc. after disconnecting and reinstallation of the same complete in all respect. (NOTE :- Pump installed at underground water tank)

1

-

-

... More
Repairing of Heat Convectors including replacement of all necessary spares to make them operational including following spares.

-

-

-

... More
Heating Element

17

-

-

... More
Blower Motor

17

-

-

... More
Thermostat

15

-

-

... More
Repairing of Geysers of all make & capacity including replacement of necessary spares and following spares to make them operational.

-

-

-

... More
Heating Element 2 KW

7

-

-

... More
Thermostat

7

-

-

... More
Assemebly

4

-

-

... More
Repairing of food Hot Case (Bainmarie) of all make & capacity including replacement of necessary spares and following spares to make them operational.

-

-

-

... More
Heating Element

5

-

-

... More
Thermostat

5

-

-

... More
Repairing of Fly Insects Killer instuments all make including replacement of necessary spares and following spares to make them operational.

-

-

-

... More
Ultra Voilet Tube 20 W

3

-

-

... More
High Voltage Transformer

2

-

-

... More
Repairing and over hauling of Exhaust Fan 30" sweep, 3-phase including rewinding of motor with enamelled copper wire, replacement of bearings / bush, repairing of shaft, disconnecting and re-installation of the same complete in all respect (Hq)

1

-

-

... More
Repairing and over hauling of 1 Phase, 2 HP Monoblock Pump Motor including replacement of water seal, rusted nut & bolts, repairing of shaft etc. after disconnecting and reinstallation of the same complete in all respect. (Hq)

-

-

-

... More
Rewinding of Motor with enamelled copper wire

2

-

-

... More
Replacement of Bearings

2

-

-

... More
Replacement of Impeller

2

-

-

... More
Supplying and fixing of Float switch for sewage pump of KSB make 1 HP including all necessary accessories, connection, testing and commissioning etc. complete as required.

1

-

-

... More
AMC for Grundfos make pressure Booster system including booster pump with motor, control panel, Pressure Gauge, Pressure Switch, Pressure Tank etc complete as required (Services from OEM / authorized service centre only)

1

-

-

... More
Repairing and over hauling of 3 Phase, 2 HP Monoblock Pump Motor including replacement of water seal, rusted nut & bolts, repairing of shaft etc. after disconnecting and reinstallation of the same complete in all respect.

-

-

-

... More
Rewinding of Motor with enamelled copper wire

1

-

-

... More
Replacement of Bearings

1

-

-

... More
Replacement of Impeller

1

-

-

... More
Sub - Head V :- Buy Back Item "As is where is basis".

-

-

-

... More
Salvage value of dismantled / old Wall Mounting fan 400 mm sweep "As is where is basis"

10

-

-

... More
Salvage value of dismantled / old Pedestal fan 400 mm sweep "As is where is basis"

3

-

-

... More
Salvage value of dismantled / old Exhaust fan upto 450 mm sweep "As is where is basis"

3

-

-

... More
Salvage value of dismantled / old flouresent tube light fitting 1 or 2x 36 Watt "As is where is basis"

15

-

-

... More
Salvage value of dismantled / old Ceiling Fan 1200 mm sweep "As is where is basis"

2

-

-

... More
Salvage value of dismantled / old 100 Watt LED Flood Light "As is where is basis"

5

-

-

... More
Salvage value of dismantled / old Recess / surface light 12 W "As is where is basis"

25

-

-

... More
Salvage value of dismantled / old Hand Dryer "As is where is basis"

3

-

-

... More
Salvage value of dismantled / old 1250 Amp 4 pole on-load changeover switch "As is where is basis"

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.