Central Road Research Institute Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Central Road Research Institute - CRRI Tender
Manpower Supply
Eprocure
Opening Date12 Oct 2021
Closing Date20 Oct 2021
Tender Amount₹ 18,17,116
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Foundation Related Works For Creation Of Testing Facilities For Bridge Expansion Joints Facility At Bes Div. Of Crri
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_CSIR_91192_1Bid Award Id
ViewTender No
QSP/MD/Foundation BES/2021Tender Authority
Central Road Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolishing cement concrete manually/ by mechanical means including disposal of material within CRRI campus as directed by the Engineer-in-charge.
-
-
-
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
24
-
2007.1
Dismantling old plaster or skirting, wall tile floor vitrified tiles raking out joints and cleaning the surface for plaster including disposal of rubbish within CRRI campus or as directed by the Engineering in Charge.
4
-
45.05
Dismantling of washbasin/ W.C.'s & its fittings including stacking & depositing of useful material in the CRRI Main Store & disposal of unserviceable material within CRRI campus as directed.
1
-
744.6
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge. Internal Work- Exposed on wall
5
-
2.85
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond CRRI campus, for all leads including all lifts involved. Complete as directed by the Engineer in Charge. ( for payment actual cubical content of dismantled material will be taken to the respective items)
40
-
219.35
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within CRRI campus as dirceted.
-
-
-
All kinds of soil.
28
-
286.85
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
4
-
253.95
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
1:4:8 (1cement: 4coarse sand:8 graded stone aggregate 40mm nominal size)
23
-
6326.05
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
17
-
7785.65
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge: All kinds of soil
7
-
107
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) .
2
-
6658.25
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
1
-
8288.35
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
-
-
-
Cement mortar 1:4 (1 cement : 4 coarse sand)
64
-
1018.05
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
140
-
951
Centering and shuttering including strutting,propping etc. and removal of form for:
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete and access platform with water proof ply 12 mm thick
66
-
307.95
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
3280
-
78.2
12 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand)
29
-
294.35
15 mm cement plaster on rough side of single or half brick wall of mix: (1 cement : 6 coarse sand)
43
-
339.1
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within CRRI Campus as directed by the Engineering in Charge. with cement mortar 1:4 (1 Cement : 4 Coarse sand)
5
-
478
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
86
-
20.85
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge.
-
-
-
For door/ window/ clerestory window/Air Exhaust opening etc
9
-
1046.95
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge
2
-
243.1
Providing and fixing 1st quality ceramic rectified digital wall tiles with highlighter of any approved pattern/shade & in combination, conforming to IS : 15622 (thickness to be specified by the manufacture) of approved make in all colours, shades of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/sqm including pointing in white cement mixed with pigment of matching shade complete.
3
-
1063.45
Providing and applying white cement based putty of avrage thickess 1mm of approved brand and manufacture , over the plastered wall surface even and smooth complete
86
-
123.85
Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete. as per manufacturer's specification: up to 10 mtr hight
-
-
-
Two or more coats on old work/ new work
749
-
92.75
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
-
-
-
Two or more coats on new work
300
-
131.45
Providing and fixing P.V.C. waste pipe for sink or basin including P.V.C. waste fittings complete. 32 mm dia.
1
-
104.35
Providing and fixing C.P. brass angle valve chilli/bath/parko make for cistern, water jet, basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore
-
-
-
Single way angle valve
1
-
500.35
Making connection of G.I. /CPVC distribution branch with G.I. main of following sizes by providing and fixing tee, Union including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
1
-
757.1
Providing and fixing C.P liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
1
-
146.3
Providing and fixing 600x450mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws & washers complete.
1
-
1411.15
Providing and fixing Counter top type white Vitreous china wash basin of (550x400mm) of approved colour and shade with central 15mm C.P.brass pillar tap Parko or equivalent make ,32 mm C.P. brass waste of standard pattern, including C.P.brass trap, union,brackets to support at bottom or by other means etc wherever required.Complete in all respect as directed by the Engineer-in-Charge.
1
-
2731.45
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
1
-
600.35
Providing & Fixing PVC flooring make Armstrong equvelent 2mm thick laid in proper level with adhesive etc. if required complete in all respect as per standard specifications and as directed by the engineer-in-charge.
22
-
434.16
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
-
-
-
15 mm dia nominal bore
50
-
267.5
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
-
-
-
15 mm nominal bore
4
-
262.3
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20 mm Nominal outer dia. pipe.
-
-
-
Concealed Work
5
-
513.75
Providing and fixing soil , waste and vent pipes/rain water pipe using ISI marked P.V.C pipes (mini.6 kgf/sq.cm.) by using P.V.C. solvent of Pidilite or Prakash or equivalent make i/c fittings e.g.socket, bend, Tee (with or without access door as per requirement) etc. Before joining the pipes, the ends should be properly cleaned and roughend. Complete in all respect as per standard procedure and as directed by the Engineer- in- charge.
-
-
-
110mm dia.
20
-
319.75
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
73
-
928.65
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
10
-
783
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
20
-
146
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
200
-
167
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
160
-
233
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
120
-
200
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
100
-
308
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
80
-
394
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
30
-
752
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
16
-
401
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
6
-
495
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
2
-
848
Supplying and fixing of 8 way VTPN (IP43 protection)Metal door MCCB distribution board (make : Legrand, L& T or equivalent) providing with suitable cable end box for three phase Outgoing with provision for MCCB as incomer with insulated vertical phase bus-bars, nutral bars with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnecting wire set, cable ties and circuit identification lables with provision of 4 pole MCCB as incomer and TP MCBs as outgoings including painting,earthing, connection, testing, commissioning etc as required. Incomer - DRX type ,FP MCCB, Thermal release range 125 Amp,(Icu-36kA) - 1No. Outgoing - 63 Amp TP MCB(10kA) - 2 Nos., 32 Amp TP MCB(10kA)-02 Nos. 10-32 A SP MCB (10kA)-12 Nos. Model 5077 59 of Legrand /L & T or equivalent.
1
-
43372
Supplying and fixing of 8 way VTPN (IP43 protection)Metal door MCCB distribution board (make : Legrand, L& T or equivalent) providing with suitable cable end box for three phase Outgoing with provision for MCCB as incomer with insulated vertical phase bus-bars, nutral bars with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnecting wire set, cable ties and circuit identification lables with provision of 4 pole MCCB as incomer and TP MCBs as outgoings including painting,earthing, connection, testing, commissioning etc as required. Incomer - DRX type ,FP MCCB, Thermal release range 125 Amp,(Icu-36kA) - 1No. Outgoing - 32 Amp TP MCB(10kA) - 4 Nos. 63 Amp TP MCB(10kA) - 2 Nos., 10-32 A SP MCB (10kA)-6 Nos. Model 5077 59 of Legrand/L & T or equivalent.
1
-
44360
Supply and installation of 450 mm sweep size metal body industrial wall bracket fan including connections as required. Model FHACWSTSCL18 of Havells/Crompton/Standard/Usha
12
-
7629
Providing & fixing of CRCA Sheet steel powder coated encloser with 1 no.63 Amp, 'C' curv-10 KA, FP MCB and Din Channel for installing it including connection & body earthing complete as required. Model 5077 93 of Legrand or equivalent.
5
-
3251
Providing & fixing of CRCA Sheet steel powder coated encloser with 1 no. 32 Amp, 'C' curv-10 KA, FP MCB and Din Channel for installing it including connection & body earthing complete as required. Model 5077 93 of Legrand or equivalent.
5
-
2518
Supply of 450mm sweep, 230 Volt, 1440 rpm, Industrial Heavy Duty Exhaust Fan as required. (Make: Orient/Havells/Standard/CG or equivalent.)
4
-
4805
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required up to 450mm sweep
4
-
363
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
4
-
168
Supply of 1.1 KV grade, XLPE/ PVC insulated, PVC seathed, Aluminium conductor armoured power cables conforming to IS 7098 ( Part - 1) / IS 1554 ( Part - 1) and ISI marked/Havells/ Polycab/Gloster of following sizes. 3 & 1/2 core 70 sq mm armoured cable.
40
-
379
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/recess as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
10
-
104
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm
30
-
38
Supply of 1.1 KV grade, XLPE/ PVC insulated, PVC seathed, Aluminium conductor armoured power cables conforming to IS 7098 ( Part - 1) / IS 1554 ( Part - 1) and ISI marked/Havells/Polycab/Gloster of following sizes. 3 & 1/2 core 300 sq mm armoured cable.
50
-
1301
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm
35
-
96
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
15
-
182
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38mm)
4
-
368
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70mm)
2
-
936
Supply,Installation, testing and commissioning of 18 W LED tube light fitting , complete with all accessories and tubes etc. directly on ceiling / wall / fallceiling, including connections with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. Make ;-Bajaj / Philips / Crompton
8
-
413
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
80
-
37
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
40
-
90
Supply & Installation of 70W LED high bey multi- functional LED luminaire industrial fittings with all accessories e.g. clamps, pipe , nut -bolts , connection, testing, commissioning etc. all complete as required. (Model BAYBRITEFLAREHB70WLED857PWBBOLTG of havells or equiv. equivalent)
26
-
6109