Border Roads Organisation Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 1,09,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BRO_671114_1Bid Award Id
ViewTender No
NIT-05-2024-25Tender Authority
Border Roads Organisation ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SUPPLY INSTALLATION TESTING AND COMMISSIONING OF VARIABLE REFRIGERANT VOLUME AIR CONDITIONING ALONG WITH ASSOCIATED ACCESSORIES IN G4 LGFS BUILDING AT HQ DGBR COMPLEX SEEMA SADAK BHAWAN RING ROAD DELHI CANTT NEW DELHI
BOQ Items
... More
14 HP
1
-
-
... More
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50 Hz AC supply, complete, as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and19 Degree C WB temperature. The IDU unit should be with wireless remote, unit should have occupancy sensor and specifications as required. IDU Capacities in TR are as under:
-
-
-
... More
1.6 TR Cassette
21
-
-
... More
2 TR Cassette
12
-
-
... More
Supply, Installation, Testing and commissioning of refrigerant piping Y joints set as required to connect the indoor units complete.
30
-
-
... More
Supply, Installation, Testing and commissioning including vacuumization and Nitrogen testing of the following nominal sizes soft/hard drawn copper refrigerant piping for VRV/VRF system for Refrigerant R 410 ,complete with fittings with suitable adjustable ring type hanger supports, joining/brazing includes accessories, insulated with XPLE Class- O tubular insulation/ with Class O closed cell elastomeric nitrile rubber tubular sleeves of specified thickness as given below for Suction and Liquid lines, all accessories as per specification etc as required/approved by consultant. The cost should also include the core's to be made for piping and sealing the core cuts to airtight joints.
-
-
-
... More
6.4 mm (OD)(Soft Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
100
-
-
... More
9.5 mm (OD)(Soft Drawn) with tube thickness 1.2 mm with 19 mm thick insulation
50
-
-
... More
12.7 mm (OD)(Soft Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
100
-
-
... More
15.86 mm (OD)(Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
80
-
-
... More
19 mm (OD)(Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
75
-
-
... More
22.2 mm (OD)(Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
120
-
-
... More
28.58 mm (OD)(Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation.
180
-
-
... More
34.9 mm (OD)(Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation
6
-
-
... More
Making core cuts in brick wall of following sizes complete with sealing, Putty & painting work (water tight joints)
-
-
-
... More
50 MM
10
-
-
... More
75 MM
5
-
-
... More
100 MM
2
-
-
... More
Supply, Installation, Testing and commissioning of PVC (minimum 15kg/sq cm pressure rated) drain water piping complete with fittings (elbows, tees, reducers, sockets, u-trap etc.) supports, jointing duct insulated with XLPE class O tubular insulation and any other item required to make the system complete. Nominal diameters of pipe in mm as indicated below :-
-
-
-
... More
25 mm dia pipe, Insulation thickness -9 mm
40
-
-
... More
32 mm dia pipe, Insulation thickness -9 mm
100
-
-
... More
40 mm dia pipe, Insulation thickness -9 mm
150
-
-
... More
Supplying and installing of 300 mm (width) X 75 mm (depth) X 1.6 mm (thickness) perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required hot dip with cover only for outside area including scaffolding upto 12 mtr.
100
-
-
... More
Supplying and installing of 200 mm (width) X 62.5 mm (depth) X 1.6 mm (thickness) perforated M.S. cable trays painted with powder coating with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
200
-
-
... More
Electrical distribution panel For IDU : Supplying, installation, testing & commissioning of cubical type wall / floor mounted Distribution Panel suitable for Outdoor application for 415V, 3 Phase, 63A, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA steel sheet 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having Suitable Amp capacity extensible type Copper bus bars of high conductivity, with short circuit withstand capacity of 50kA with entire panel shall have a common earth bus of suitable size at the rear with 2 Nos earth stud, PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates. providing & fixing of necessary MCBBs,6A & 10A MCCB Single Pole required.
1
-
-
... More
Main Electrical distribution panel For ODU : Supplying, installation, testing & commissioning of cubical type wall / floor mounted Distribution Panel suitable for Outdoor application for 415V, 3 Phase, 40A, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having Suitable Amp capacity extensible type Copper bus bars of high conductivity, with short circuit withstand capacity of 50kA with entire panel shall have a common earth bus of suitable size at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of Copper bus bars and control wiring with 1.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates providing & fixing of necessary MCBBs.
-
-
-
... More
Outgoings: Supplying and fixing following outgoing complete connection, inter-connection etc. as required
1
-
-
... More
2 Nos 250Amp,Four Pole 50KA, MCCB with Thermal Magnetic release with O/C,S/C & E/F protection release
1
-
-
... More
Supply & Installation of interconnecting control & transmission Copper wiring 2C x 1.5 Sqmm as communication cable required in PVC conduit.
350
-
-
... More
Supply & Laying fixing of following size XLPE insulated and PVC sheathed Copper conductor armoured cable as required of 1.1 KV grade complete as required. (ISI Marked) (In ground/in pipe/in duct/on surface/ on cable tray) with all complete with cable tray clamps, saddles, thimble cable gland etc including effective proper connection to the equipment as required.
-
-
-
... More
4C X 6 Sq.mm
80
-
-
... More
4C X 10 sq.mm (Black, Green & Any Phase Color)
80
-
-
... More
Supply of following XLPE insulated Aluminium conductor armoured cable 650/1100 volts complete with cable tray clamps, saddles, thimble, cable gland, etc including effective proper connection including all necessary termination and clamping etc to the equipment as required
-
-
-
... More
4C x 120 Sq-mm
50
-
-
... More
Supply & Laying/fixing of following size XLPE insulated and PVC sheathed Copper conductor flexible cable as required of 1.1 KV grade complete as required. (ISI Marked) (In ground/in pipe/in duct/on surface/ on cable tray) with all complete with cable tray clamps, saddles, thimble cable gland etc
-
-
-
... More
3C x 1.5 Sq-mm
350
-
-
... More
Earthing complete with galvanized steel earth plate electrode 60 cm× 60 cm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized earth lead wire but using galvanized iron strip 32mm × 6 mm as earthling lead with GI wire and (3 X 25mm) strip earthling.
1
-
-
... More
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.
25
-
-
... More
Point wiring with copper conductor cables FRLS
-
-
-
... More
One light point or one fan point controled by one swith with cables 1.5 sq mm size
25
-
-
... More
One light point or one fan point controled by one swith with cables 2.5 sq mm size
25
-
-
... More
Dismantling and Reassembling Existing False ceiling with False Lights
-
-
-
... More
Dismantling and Reassembling Existing False ceiling, Lights and fans Mounted on False Ceiling and Assembling False Ceiling Lights and fans with all proper connections after the cuts outs for the CST Indoor Units are made as per dimension as required as per the drawing.
200
-
-
... More
M&L for Taking down and refixing in the same opening of chowkhats or frame (without taking off shutters from frame) not exceeding 1.5 Sqm (Note:- Existing window/Partition walls made out of UPVC or Aluminium partition whatever at site)
10
-
-
... More
B. Part-II (AMC)
Annual Comprehensive routine operation (including 3 operator per Shift & 2 Shifts per day) and preventive maintenance Comprising of VRF/VRV unit i/c all accessories, consumable like oil, gas, PCBs & other items to keep the system in perfect running condition as required for the following periods after Guarantee Period subsequent to successful commissioning and handing over.
-
-
-
... More
1st Year after expiry of 1 year Guarantee period
68
-
-
... More
2nd Year after expiry of 1 year Guarantee period
68
-
-
... More
3rd Year after expiry of 1 year Guarantee period
68
-
-
... More
4th Year after expiry of 1 year Guarantee period
68
-
-
... More
5th Year after expiry of 1 year Guarantee period
68
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements