If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Ambedkar University Delhi - AUD Tender
Coronavirus COVID 19
Eprocure
Opening Date20 Dec 2018
Closing Date11 Jan 2019
Tender Amount₹ 42,77,286 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 85,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Renovation Of Room No 402 And Ceced In Admin Block Of Kashmere Gate Campus At At Ambedkar University Delhi, Delhi -110006
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_AUD_163954_1Bid Award Id
ViewTender No
08/EE/EMU/AUD/2018-19Tender Authority
Ambedkar University Delhi ViewPurchaser Address
-Website
http://https://aud.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
250
-
-
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
37
-
-
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws
etc. complete. Twin rubber stopper
27
-
-
Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300X16mm
27
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300X10mm
54
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200X10mm
40
-
-
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm
54
-
-
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100mm
20
-
-
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
2050
-
-
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone/ cosmos / Hexa or equivalent of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by engineer-in-charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, noncombustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/m 0 KC.
270
-
-
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work
360
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
360
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
360
-
-
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below
10
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
30
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a
single 15 mm C.P. brass pillar tap
2
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion, Powder coated aluminium (minimum thickness of powder coating 50 micron)
2000
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
580
-
-
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both
sides
155
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. With float glass panes of 5.50 mm thickness
140
-
-
Demolishing brick work in cement mortarmanually/ by mechanical means including stackingof serviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer-in-charge. In cement mortar
2
-
-
ELECTRICAL
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 q.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
81
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FLRS PVC insulated copper conductor, single core cable in surface/ recessed stell conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
150
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FLRS PVC insulated copper conductor, single core cable in surface/ recessed stell conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
260
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 X 4 sq. mm
400
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 6 X 4 sq. mm
100
-
-
Supplying and fixing GI Box alongwith modular base, cover plate, 2 no 16A modular switch & 2 nos 6 pin 15/16 amps socket in recessed etc as reqd for computer terminal points
35
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
35
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 2 module
35
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required RJ 45 Computer Socket Cat-6
35
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required Telephone Socket outlet
35
-
-
Supplying and drawing UTP 4 pair Cat 6 LAN Cable in the Existing surface/ recessed steel/ PVC conduit as required
500
-
-
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet stell enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
13
-
-
Supplying, Installation testing & commissioning of high efficency LED luminaire surface/ recess mounted made of CRCA powder coated body with PMMA diffuser to provide high LOR and soft glare free light suitable for 600x600mm size i/c connection with PVC insulated FRLS copper conductor cable of size 3x1.5 sq.mm etc. complete as reqd.
30
-
-
SITC of intergral round/ square shaped surface mounted 12 W high powered LED warmwhite light fitting with opal diffuser.
15
-
-
Supply and fixing of 400 mm sweep wall mounted fan complete with inbuilt Electronic Regulator, Blade, wire lead with moulded plug top etc. as reqd.
3
-
-
Supplying, installation, testing & commissioning of 1400 mm ceiling fan, including wiring the down rods of standard length ( up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper, conductor, single core cable etc. as required.
13
-
-
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
13
-
-
Supplying and fixing following way prewired TP&N MCB distribution board of stell sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as reqd. 12 way (4+36), Double door
2
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
72
-
-
Providing and fixing following rating and breaking capacity and pole MCCB in existing TPN DB including, making connections, etc. as required. 100 Amp, 16 KA, TPMCCB
2
-
-
Supplying, errecton of wall mounted 6 kg capacity multipurpose ABC type MAP-90 (stored pressure type) fire extinguisher, ISI marked complete as eqd.
4
-
-
Supplying and laying of one number PVC insulated and Al. Conductor armored power cable of 1.1 KV grade of following size direct on cable tray as required. 4 X 25 Sq. mm
50
-
-
S&F on surface/wall mounting U plastic power cable management system/tranking of size 105 mm (w) x 50mm (d) with flaxible cover, cover joint, base joint, end caps complete of 85mm (w) provision of groove for dividers lenth of 2.00 mte suitable for drawing of wires complete as reqd.
100
-
-
Supplying, Installation, Testing and Commisioning of 2 Ton Split type Air conditioners (minimum 3 star 2018 model) having minimum cooling capacity of 1.8TR to 2TR, suitable for operation on 230V, 50 Hz single phase capable of performing Cooling, dehumidifying, air circulating and filtering complete connection with refrigerant copper pipe heavy guage 2/8"/3/8" and 5/8" covered with minimum 10 mm thick insulation i/c 3 x 2.5 sq.mm flexible copper conductor wire wrapped in flexible pipe irrespective of length and also providing 25 mm dia PVC drain connection including accessories, fixng on surface with clamp to the nearest drain connection pipe complete with repairing of wall with minor civil work at site. (Make: Mitsubishi, Hitachi, Carrier, Daikin). The cost includs the refrigerant copper pipe,insulation, copper conducto up to 3.0 meter.
13
-
-
Supply and fixing of Voltage Stabilizer of following capacity for 2.0 Ton Air-Conditioner complete as reqd. (Input 145-280 volts) (Output 195-245 volts) (Make: Bluebird,V-Gauard,Microtech ,Livguard)
13
-
-
providing and fixing of hard drawn threaded wired PVC drain pipe line of 25mm dia for drain out condensed water etc as required.
150
-
-
Providing and fixing of M.S outdoor, floor/ wall mounting powder coated stand suitable for 2.0 Ton capacity split type A.C outdoor unit complete as reqd.
13
-
-
Providing & Laying of refrigerant copper piping of size (5/8" & 1/4" dia) from indoor unit to outdoor unit of split type AC duly insulated along with necessary support etc complete as reqd.
150
-
-
Providing and fixing of 3 core flexible PVC insulated wire of size 2.5 sq. mm i/c testing. Surface etc as reqd.
150
-
-
Supply & fixing and testing Digital EPABX systems with 240 Port Main Unit, CPU DX plus, AC Driven Power supply, 1PRI, 8 P&T 6 Digital Card & Extensions card ( 8x16= 128) with Caller ID i/e Connection etc as req( Creative/Empire/Adhunik)
1
-
-
Supplying, Fixing and Testing & Commissioning of UPS 1KVA 20 minute back up for above EPABX system for smooth functioning of above system in case of power failure as reqd (paradyne/Elnova/microtek)
1
-
-
S/I/T/C/ of KTS telephone with trunk status display status, line busy status & Incoming & Out coming Call facility etc. as reqd. ( Creative/Adhunik/Empire make)
2
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper condutor, unarmored telephone cable in the existing surface/ recessed steel/ PVC Conduit as reqd. 4 pair
500
-
-
Supplying, fixing & laying of 50 pair armourded Jelly Field copper conductor 0.5 mm dia cable on surface of the wall as reqd. (Make:- Delton/ Finolex/ Plaza)
380
-
-
Supplying, fixing & laying of 20 pair armourded Jelly Field copper conductor 0.5 mm dia cable on surface of the wall as reqd. (make:- Delton/ Finolex/ Plaza).
100
-
-
Supplying & fixing of heavy duty double lock 25x25 mm PVC Channel on surface of the wall as reqd. (make:- SGI/ MK/ API).
150
-
-
Supplying, installation, testing & commissioning of push button phone etc. with caller ID & Speaker Phone as reqd. (Make:- Panasonic/ Beetel/ BPL).
40
-
-
Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground i/c excavation, protective covering and refilling the trench etc. as required.
200
-
-
Supply & Fixing of main Distribution box with module as req. (Krone/Creative/Indostar) A) 200 pair
1
-
-
Supply & Fixing of main Distribution box with module as req. (Krone/Creative/Indostar) B) 50 pair
4
-
-