All India Institute Of Medical Sciences Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

All India Institute Of Medical Sciences - AIIMS Tender

Goods
Healthcare and Medicine
Eprocure
Opening Date19 Oct 2020
Closing Date7 Dec 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Disposable pulse oximeter sensor • Should be compliant with the equipment intended to continuously estimate and display non-invasively a patient's arterial blood oxygen saturation and pulse rate. • Proposed sensors must comply with Nellcor Technology. • Digit sensors should be available in Adult, Pediatric, Neonatal and Infant sizes to accommodate diverse patient sizes, weights and needs. • Seller must have all types of sensors available (e.g., finger, forehead, and ear). Sensor must be available in Adult, Pediatric, Infant and Neonatal Sizes. • Sensor extension cables must be available in 4' and 9' lengths. • The sensors must be compatible with all generations of Nellcor Oximetry Technology in Nellcor Oximeters and OEM/Licensee Multi-para meter systems with all generation of Nellcor technology. • The sensor shall resist inadvertent displacement. • The sensor shall resist interference from ambient light. • The sensors shall not be adversely affected by fluid spills or common disinfectant solutions.

2000

-

-

... More
Flexible tubing-100% Silicone (Sterile)-6mm • Highly flexible medical grade silicone tubing, autoclavable, temperature from - 85 degree Celsius to 250 degree Celsius, can be sterilized by Ethylene Oxide

200

-

-

... More
Flexible tubing-100% Silicone (Sterile)-8mm • Highly flexible medical grade silicone tubing, autoclavable, temperature from - 85 degree Celsius to 250 degree Celsius, can be sterilized by Ethylene Oxide

200

-

-

... More
Thermo dilution Pulmonary artery catheter • Flow directed 5-lumen balloon tipped pulmonary artery catheter. 7.5 Fr in diameter &≈ 110 cm in length

200

-

-

... More
Swan Ganz pulmonary artery catheter • Flow directed 3 lumen balloon tipped pulmonary artery catheter, 7 Fr in diameter &≈110 cm in length • Should be able to give PA pressure, PAWP & RA Pressure when connected to transducer. Should have proximal infusion port at 30 cm. Recommended guide wire size 0.89 mm. • It should come with one volume-limiting syringe of 1.5cc for balloon inflation

200

-

-

... More
Swan Ganz pulmonary artery catheter introducer kit • Percutaneous Sheath introducer set should have bonded hemostasis valve & side port along with .035 x 45 cm straight & “J” tip guide wire for introducing 7.5 Fr& 8.0 Fr PA Catheter. • It should have sheath diameter of 8.5 F & sheath length of ≈11 cm. It should be made of radiopaque polyurethane & should have a coating of Heparin as well as antimicrobial material on entire sheath surface. • It should come with 1 catheter contamination shield, ≈80 cm in length. • It should have one 4-waystopcock, one vessel dilator & four 4x 4gauze pads. • One disposable scalpel, # 11 blade & one 18 ga x 2 ½ thin wall needle.

200

-

-

... More
Foley Catheter (Silicone coted Latex ) (24Fr) • Foleys catheter Manufactured from natural rubber latex coated with silicone to eliminate the risk of encrustation. • Symmetrical large capacity balloon ensuring a straight tip and proper flow for good sphincter action to prevent bladder leakage. • Coned distal end with burr free eyes for atraumatic intubation. • Hard valve to ensure easy inflation and deflation of balloon. • Colour coded for instant size identification. • Sterile, individually packed in peelable pack

200

-

-

... More
Silicone Condom Type Male External Urinary Catheter S,M,L,XL (20mm, 25mm, 30mm, 35mm) • Silicone Condom Type Male External Urinary Catheter • Made up of odour-free silicone with Good biocompatibility. • Urethral catheterization drainage for male patients • Supplied with adhesive strap

200

-

-

... More
Supra-pubic cystostomy kit (all sizes) • Ready to use system • Pre-assembled silicone catheter (10 Fr, 14 Fr) into the cannula • Thin and sharp stainless steel cannula covered with protection tube. • Length 50 cm, 65 cm

200

-

-

... More
Double lumen dialysis catheter ( All sizes) • Double D design • Atraumatic tip for smooth insertion • Reinforced hub to minimize kinking during insertion • Radiopaque

600

-

-

... More
Triple Lumen Haemodialysis Catheter (12 Fr) • Modified Double D design • Third lumen (19G) for infusion of fluid, blood products, medication or blood sampling • Atraumatic tip • Reinforced hub to minimize kinking during insertion • Radiopaque

400

-

-

... More
Dialysis tubing kit (adults) • Blood Tubing Set for Haemodialysis designed specifically to connect patient with an external system that extracts blood of the patient to the dialyzer and reverts patient’s blood from the dialyzer. • Should have Arterial and Venous line • Should have de-foaming chamber • Color coded ergonomic clamps and dialyzer connectors with tethered • Kink resistant tubing eases handling and ensures fast priming. • EO Sterile, Non-Toxic and Pyrogen Free.

400

-

-

... More
Dialysis tubing kit (Paed) • Blood Tubing Set for Haemodialysis designed specifically to connect patient with an external system that extracts blood of the patient to the dialyzer and reverts patient’s blood from the dialyzer. • Should have Arterial and Venous line • Should have de-foaming chamber • Color coded ergonomic clamps and dialyzer connectors with tethered • Kink resistant tubing eases handling and ensures fast priming. • EO Sterile, Non-Toxic and Pyrogen Free.

400

-

-

... More
Antibacterial treated surgical tape 1 inch x 10 mts.

1000

-

-

... More
Antibacterial treated surgical tape 2 inch x 10 mts.

1000

-

-

... More
Antibacterial treated surgical tape 3 inches x 10 mts

1000

-

-

... More
Negative pressure wound therapy for surgical wounds not healing by primary closure. (10 Fr, 12 Fr) Device for close wound drainage under negative pressure post operatively with option to use one or two catheters. Redon drain catheters provided with radio opaque line and smooth eyes. Connecting tube to be kink resistant and is provided with additional strength to withstand the suction. Easy to depress chamber to activate the suction of bellow unit.

200

-

-

... More
Leukocyte depleting filter • Blood set should have drip chamber and filter with proven leucocyte reduction properties for leucocyte free blood transfusion for organ transplant use. • It should have filter size 40 microns and 180 sq. cm of filter area and should have attached IV set with a luer lock tip

1000

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.