Public Works Department Tender

Download documents of Daman & Diu PWD Tender

Public Works Department - PWD Tender

Civil And Construction
Building Construction
Eprocure
Opening Date8 Aug 2019
Closing Date10 Oct 2019
Tender Amount₹ 91,48,23,375 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹78,300/MT*
Daman & Diu

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M.S. Above Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / gaskets / Nut bolts etc., and laying on the surface including painting with one coat of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required: 100 mm dia.

516

-

-

... More
SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 4 Sq.mm x 4C CU. Cable

30

-

-

... More
Sec.9.0 Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. 2nd Year after DLP

1

-

-

... More
Supplying, installation, testing and commissioning of 42U Floor standing 19" networking enclosure as per specification and complete with all accessories. (upto size - 800mmW x 1000mmD) as required. (along with horizontal cable manager & vertical cable manager, PDU with minimum 12 Nos. 16 Amp socket, as per technical specification etc. as required.

2

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 3900 CFM / 40mm Static Pressure for Toilet

2

-

-

... More
Sec.9.0 Flooring works Providing material and labour for laying Ceramic tiles 6mm thick in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) and fixed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Sample and mockup shall be approvd before procurement of material.

50

-

-

... More
Providing material and labour for laying integral cement based water proofing treatment (India type brick bat) including preparation of surface as required for treatment of roofs, balconies, terraces etc with average thickness of 120 mm and minimum thickness at khurra as 65 mm and consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with wired finish to receive china mosaic flooring. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge for all height all level.

9219

-

-

... More
Supply, Installation, Testing and Commissioning of Indication Lamp The module should have LED indication of calls, presences and reminders in the relevant colours conforming to VDE0834, consist of White,RED, Blue and Green LED chamber each with 3 ultrahigh LEDS up to 10,000 operating hours.

10

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-A EQUIPMENT NON-UPS PANEL As per Single line diagram

1

-

-

... More
Providing and arranging in position work table with modesty panel without CPU hanger system of Enterprise 1500 of Godrej or equivalent of approximate size 1500 Width mm x 750 Depth mm x 725 Height mm with knock down construction system. Total assembly shall be maade of 25mm & 18mm thick prelaminated partical board of approved shade with PVC membrane pressed on it, PVC lipping at exposed edges, CRCA member and MS ERW tube finished epoxy polyster powder coating, Required hardware shall be provided i.e. wire management system, plastic cap for cable travel, leveler glide, handle, lock, sliding mechanisam etc.

1

-

-

... More
Providing material and labour for fixing 25mm diameter (1.5mm thick) SS 316 satin (brush) finish Disabled Grab Rails/ handle of 600mm long of approved make with necessary SS 304 grade screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

48

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B GROUND FLOOR EQUIPMENT NON UPS PANEL As per Single line diagram

1

-

-

... More
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.

3

-

-

... More
Supply & Installation of Under Deck Insulation with Class ‘O’ Nitrile Rubber with tough Aluminum foil facing & as per detail specifications - 25mm

3700

-

-

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Single pair, 2-core, 1.5 sqmm, For PA System

3500

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 32mm dia.

4

-

-

... More
(f) 4C X 16 SQ. MM. CU XLPE CABLE

50

-

-

... More
Design, Supply, Installation, Testing, and Commissioning of Chiller Plant Manager suitable to control 04 nos. of Water cooled chillers with VFD (2 Working + 1 Stand By + 1 Future provison), 04 Nos. Twin Cell Cooling Towers (2 Working + 1 Stand By + 1 Future provison), 04 nos. of Primary Pumps (2 Working + 1 Stand By + 1 Future provison), 04 nos. of Variable Frequency driven Secondary pumps (2 Working + 1 Stand By + 1 Future provison) & 04 Nos. of Condensor Pumps (2 Working + 1 Stand By + 1 Future provison) as per HVAC BOQ. The CPM shall be a 32 Bit microprocessor based, programmable controller, factory pre-programmed system housed in a IP54 rated panel enclosure of suitable size (and qty). Shall have integrated color graphics display for display of plant graphics, facility to change settings etc. Shall have on-board EPROM memory expandable through add-on memory card like micro SD card capable of storing sampled plant data for 5 years. Shall be capable of communicating with 3rd party BMS through Bacnet / IP. Shall have at least 2 nos. of on-board integrators for integrating chillers, open serial protocal like modbus RTU, grundfos bus, Wi Lo bus etc. Embedded web-server facility shall be optional. Shall do the function of time based scheduling, load based start / stop, run time equalization, trip / fault detection and annunciation of the high side refrigeration plant, namely; chillers, pumps, motorized on / off isolation valves etc. It shall also control the pumping system & shall co-ordinate with the primary side. Shall calculate plant load based on chilled water return header temperature. Price to include lump sum supply and laying of 2C x 1.0 sq mm armored FRLS signal cable from field sensor / actuators up to controller.

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 23.21 TR / 10250 CFM For Reception Waiting & Corridor at First Floor

1

-

-

... More
Providing material and labour for fixing SS 316 grade push-pull pair of handle of size 600 mm long x 32 mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified.

179

-

-

... More
Providing and Fixing 15 mm dia. CP brass extended lever handle pillar cock with ceramic disc cartridge for all laboratory sinks or as directed by the Engineer-in-charge, complete, making all necessary connections etc of approved make.

73

-

-

... More
SITC of 2 compatement 100 mm x 50 mm wall trunking/race way with cover and all accessories made out of PVC .

130

-

-

... More
Providing and arranging in position storage unit having Sliding door of VSDU-5 of Godrej or equivalent of approximate size 900mm x 450mm x 1200mm. Storage unit shall be made out of CRCA steel - D grade as per IS 513 having epoxy poyester powder coating of 50 microns. Storage unit shall be of knock down construction with adjustable self arangement and all required hardware i.e. handle, lock (5 lever), roller, ball bearing etc.

23

-

-

... More
Providing material and labour for fixing 1 point panic device in Contur design on active leaf and 2 point modular on inactive leaf, carry bar for rebated double door of approved make for fire and smoke check doors, with steel latch, security anti thrust latch consisting of all required accessories in silver finish. As per EN 1125, CE marked with necessary fittings etc. complete for all floor all height as recommended by manufacturer and as directed by Engineer in Charge.

10

-

-

... More
Supply & fixing of 200 pair MDF unit with required modules in a fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock, provision for earthing.

2

-

-

... More
Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. e) For 50mm dia pipes - 25mm x 54mm Nitrile Rubber Plain Tubing

19

-

-

... More
Supplying and erecting, testing and commissioning of 1x10W 600mm LED Surface Mounted indoor Linear smart Bright Battern Lights Fittings -Make Phillips or equilavent ( BN021)

61

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B SECOND FLOOR HVAC PANEL As per Single line diagram

1

-

-

... More
Providing, laying and jointing in true line and level 50mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to IS 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Pipe length per piece: 1.8 Mtrs

50

-

-

... More
Supply, installation, testing and commissioning of Butterfly valve (manual) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified: 150 mm dia.

40

-

-

... More
Supplying mterial and labour for laying of following size DWC HDPE pipe of 63mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge.

100

-

-

... More
Providing and fixing full thread coupling on each tank for inlet and outlet connections of G.I. (medium duty) as per IS: 1239, including drilling holes in the tanks at required levels, inserting the coupling in place, sealing the hole with silicon sealant, attaching the hex nuts on either side of the coupling as directed and approved by the Engineer-in-charge. (A) 65mm diameter

60

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic type Flow Meter

2

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 10.20 TR / 4450 CFM For Reception Waiting & Corridor at Second Floor

1

-

-

... More
Providing, laying and jointing in true line and level 150 diametre U.P.V.C (Type A) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.

275

-

-

... More
Providing material and labour for fixing factory made and pressed laminated 30mm thick flush door shutter of specificied thickness made of ISI marked non decorative type flush door shutters confirming to IS- 2202 (Part 1), core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers (IS 710 Grade) on both faces of shutters having 1 mm thick decorative type laminates of approved make, shade, finish on both faces of shutter fixed with phenol formaldehyde synthetic resin type adhesive conforming to IS 848 including providing and fixing external lipping with 2nd class teak wood battens, exposed (37mm x 12mm)/ concealed (35mm x 12mm) on all edges of door shutter as required with 2 coats of synthetic enamel painting including 1 coat of wood primer & lapi/ lacquer polishing with primer to all exposed side of lipping, all as per approved drawing, for all floor, all level all height etc. complete as directed by Engineer-in-charge. Measurement including lipping shall be considered for payment. Necessary hardware like hinges, pivot, handle, tower bolts, locks etc shall be separately measured and paid in the relevant tender items. Cost of laminates shall be paid in relevant tender item.

50

-

-

... More
Supply, Installation, Testing and Commissioning of Gun Metal Air Release Valve with necessary fittings. Size: 25 mm (For Riser)

8

-

-

... More
Dismentling steel work including distempering and stacking the materials with all lead and lift.

500

-

-

... More
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 128 MB RAM & 64 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Water Tanks - as per IO Summary and as per technical specification etc. as required.

1

-

-

... More
Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm outside layer and 0.8mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan with 50 mm static, 4 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), with Mixing box, filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, belt with TEFC drive motor (Eff-1) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, supplied with factory fitted matching size 2 way ON / OFF actuator type Brass / Control valve / Cu piping with required couplings and ends flanged to fit CHW In / Out piping, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan and duly internally wired and tested. Followings are capacities. (With 5 Micron Filteration) 2.19 TR / 1300 CFM For Lab at First Floor

1

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 40mm dia.

10

-

-

... More
Supply, Installation, Testing and Commissioning of integrated Audio source with the following features : Two single CD\USB\SD and DAB\FM line outputs can play music applications in two areas, The volumes of the two line outputs can be adjusted separately, CD\USB\SD has three play modes: single play, all play and repeated play, DAB\FM can preset 10 channels of programs, RS485 remote control interface as per technical specification etc. as required.

1

-

-

... More
Providing material and labour for laying average 40 mm thick machine cut polished Green kota stone slab of size upto 0.9mt length with uniform thickness double side polished at edges for parapeet wall coping, window sills, over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry or stone fixing adhesive and mechanical fastner of approved make including rounding of exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be pencil sharped and in even thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. Sample shall be approved before execution. Sample and mockup shall be approvd procurement of material.

1419

-

-

... More
Providing and arranging in position Cabinate unit beside bed with drawer and locker of Ayush of Godrej or equivalent. Overall dimension: (L)420 mm X ( W)400 mm X (H) 840 mm. Drawers and cabinate should be made of CRCA have thickness of 0.8mm and Slide should be made of MS with zinc plating & should be telescopic in nature. Top should be made of SS of grade 304 having thickness of 0.8mm. Plastic molded plastic castors with 50mm dia. Anti bacterial thermosetting epoxy polyester powder coating should done for all MS components.

300

-

-

... More
Supply, Installation, Testing, Commissioning of Water Type Differential Pressure Switch

9

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 2750 cfm, external static 50 mmwg Exhaust air fan - 1750 cfm, external static 50 mmwg

1

-

-

... More
Supply, installation, testing and commissioning of Y Strainer of CI Body flanged ends with stainless steel strainer 304 having 1.2mm perforation complete with necessary accessories: 150 mm dia.

2

-

-

... More
(c) 3.5C X 150 SQ. MM. AL XLPE CABLE

300

-

-

... More
Sec.8.0 Waterproofing works Providing material and labour for laying average 18mm thick double coat (water proof) smooth/ wired finish cement plaster on sides of masonry work/ block wall/ RCC wall, 12 mm thk first coat in CM 1:3 (1 cement : 3 coarse sand) by spraying , second coat of 6 mm of CM 1:3 (1 cement : 3 fine sand) and mixing Integral waterproofing liquid admixture for mortar in recommended proportions in both coats, finishing the surface wired finish/ smooth finish with a floating coat of neat cement slurry at 2.75 Kg/ sqm to receive the tiles for all floors, all shapes and all height including hacking to RCC surface, scaffolding, curing etc. complete for all floor, all height as directed by engineer-in-charge. Cement slurry admixed with Integral waterproofing liquid admixture for mortar in recommended proportions is to be applied before each coat and final finishing coat.

262

-

-

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 790 x 370 x 690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre / 6 litre (adjustable to 4 litre / 8 litre) including seat cover, and cistern fittings ,nuts, bolts, and gaslets etc complete.

206

-

-

... More
Providing and fixing 8mm dia C.P. / S.S. jet with flexible tube up to 1 meter long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer-in-charge.

229

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for ETPs (1 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.

1

-

-

... More
Tree plantation Supplying material and labour for planting of trees including termite treatment, and planting of plants in existing prepared tree pit or excavated pit. (height 4'-6' above bags/pots). Soil mounts 4”-6” in size. Tree plantation should be carried on neatly accurately and with perfection as per drawing and instruction given by the EIC. Plastic bags or pots should be removed carefully and soil around the roots should not be dropped or disturbed much. Bill shall be placed after completion of maintenance period but not before stabilizing the hedges. Rates for mortality to be inclusive. Providing and fixing tripod made of wooden balli, height 1.50mtr. Top bracket to be 300mm x 300mm. leg embedded in ground up to 300mm and to have tar coat. Work shall be done as shown in the drawing or as directed and approved by EIC. Excavation and soil filling shall be paid in relevant tender item.

100

-

-

... More
Providing and arranging in position Fabric finish visitor chair of Barvo of Godrej or equivalent with approved shade of fabric. The seat and back shall be made up of 12mm thick hot-pressed plywood and upholstered with fabric upholstery covers and moulded polyurethane foam. The one-piece armrests should be injection moulded from black co-polymer polypropylen. Chair hvae cantilever type MS EWR tubular frameas legs having powder coating (dft 40-60 microns).

207

-

-

... More
CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 150 mm dia.

115

-

-

... More
Providing material and labour for Extra charges for machined Perforation of required dia and pattern in flush door shutter/ compact sheet of any thickness for air circulation for all floor, all height all level as per drawing and as directed by Engineer in charge. Edges of perforation shall be finished and sharpen.

27

-

-

... More
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (d) 40mm dia nominal bore.

25

-

-

... More
Supplying and erecting, testing and commissioning of 40W LED batten Surface Mounted Industrail Corroson proof Fixture Ip 65 -Make Crompton or equilavent (IPFC112LT8-16 2X 20W)

100

-

-

... More
Providing material and labour for fixing of SS 304 grade satin finish lever action Flush tower bolt with 19mm projecting bolt (extended rod of 600mm length) aluminum casted of approved make for double shutters aluminum door, with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

87

-

-

... More
Providing and arranging in position FOLDING WHEELCHAIR WITH CUSHION of Godrej or equivalent. Overall dimension (L) 790 x (W) 600 x (H) 870mm. Foldable frame structure should be made of section 22x1.2mm A3 carbon steel with chrome finish. Cross bar should be made of A3 carbon steel with section 25.4 x 1.2mm. rear wheels should be 24 inch Solid mag wheels with alloy in the rim. Integrated handrim provide to drive the wheel chair of section 16x1.2mm A3 carbon steel with chrome finish. front wheel should be 8 inch HUB made of PA polymer and outer with solid rubber. PU molded arm rest & base should be made of ABS for better arm support. Leatherite strap should be available as for calf rest & seat of wheelchair should be made of leatherite cushion Adjustable foot rest with alluminimum die cast foot rest with updown & swivel type mechanism. Hand brakes should be provided to lock the wheelchair at desired location. Extended base with molded plastic for better grip. Anti rust chrome finsh. The manufacturer should compilant with ISO 9001, 14001, OHSAS 1800 and CE certification.

17

-

-

... More
Supply, Installation, Testing and Commissioning of Patient Handset The module will be connected with Bedside module with Intelifix connection features. The handset should have call button with Nurse sysmbol, membrane keypad with call button. optional Room or reading light control, 2.8 m cord. Handset must have antimicrobial coating on the surface and confirms to VDE 0834.

10

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.25 mm sheet

5

-

-

... More
Providing material and labour for fixing adjustable/ fixed Teflon roller bearing set with reinforced nylon casing of approved make (twin or single wheel according to weight and size) for sliding window/door as per drawing etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

50

-

-

... More
Supply, Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 60KVA UPS 3 ph in 3 ph out for balance load

1

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 3200 CFM / 40mm Static Pressure for O.T Store

1

-

-

... More
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 mt. Between supporting floor two ceiling including temporary brick or stone pillars for supporting as required. (I) Height more than 4.0 mt & upto 9.0 mt.

59

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

8

-

-

... More
Providing material and labour for fixing SS 304 brush finish solid Door Stopper with magnet, fixed type, wall mounted (square/ round) of approved make with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

172

-

-

... More
Providing material and labour for making tree pit with 800mm diameter NP2 class hume pipe with 600 mm height to be placed on the filled garden soil and outside area of the hume pipe to be filled with the good quality earth. Hume pipe shall be filled with the mixture of garden soil, farm yard manure and required pesticides etc. complete as directed by Engineer in charge. Excavation and soil filling shall be paid in relevant tender item.

100

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 50mm dia.

49

-

-

... More
CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 100 mm dia.

33

-

-

... More
Sheet steel metal enclouser for FP MCB equivalent to Legrand cat No...607884

21

-

-

... More
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 600 CFM

12

-

-

... More
Providing & Fixing M/F Suspended 12.5mm Plain Gypsum Board which includes GI Perimeter Channel is fixed along the perimeter of existing wall/ partition with the help of screws at 600mm centres. GI Ceiling Angle is suspended at up to suitable height as per sight conditions by fixing it to the GI soffit clit with Soffit Cleat and  Rawl Plug creating 1220mm x 1220mm grid. GI Intermediate channel is fixed to the GI Ceiling Angle with 2 Nos of 4.2x13 GI metal to metal screw. The GI Ceiling Section is then fixed to the GI Intermediate Channel with the help of  Connecting Clip and in direction perpendicular to the Intermediate channel at 457mm c/c. All framing and grid section shall be GI (as per IS 513) having yeild strength 300 mpa and galvanized finish of 150 GSM as per IS 277. Single layer of 12.5mm tapered edge Plain Gypsum Board (Confirming to IS 2095-Part-I, 2011) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing Compound & Joint Paper tape. The contractor should prepare shop drawings based on the concept drawing and get it approved by the Engineer-in-charge. After approval of drawings, the contractor shall prepare the sample based on the drawing and get it approved by the Engineer-in-Charge before execution. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, making grooves between wall & board or as per drawing for all floor, all level, all height etc as directed by Engineer in charge. Area of cutouts shall not be deducted and no extra payment shall be considered for additional sections provided. Only plan area shall be considered for payment.

5963

-

-

... More
Supplying, Splicing , testing and commissioning of LC type single mode pre-terminated pigtail 1mtr as per tender specification etc. as per technical specification etc. as required.

144

-

-

... More
Sec.4.0 Condenser Water Piping CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 300 mm dia.

103

-

-

... More
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 35 Sq.mm x 3.5C Al. Cable

470

-

-

... More
300 x 105 mm

20

-

-

... More
Providing and fixing Channel for optimizer of of required length as per unit. Guide channels shall consist of 'J' section 2 mm thick & 25 mm square bright bar - both connected by screws. Prior to the embedding of the guide channels with the help of raul plug & screw, the ground has to be in proper leveled condition. Guide channel shall be of same make as optiimizer and as per manufacturer's specification.

129

-

-

... More
Loop light point to be controlled from same switch.(Looping from first point)

1411

-

-

... More
Secondary Variable Chilled Water Pumping System with VFD including Supply, Installation, Alignment, Testing and Commissioning of End Suction Top discharge Back Pull out Centrifugal type Secondary Chilled water pumps as specified. The pump shall be dynamically balanced and supplied with Flexible coupling with Guard, Corrossion resistant painted MS factory supplied baseframe with necessary vibration isolators and Rubber flexible bellows at suction and discharge nozzels; Entire System including Pump, Controller and related controls shall be procured from single pump manufacturer; Design shall comply to secondary fundamentals briefly described in the tender and further as recommended by manufacturer for intended system performance; Electrical Control Panel capable of cyclic operation of pumps - Controller shall be capable of controlling upto 3 Pumps in parallel housed in IP55 Control Panel compatible for interface with Pump Starter Panel and Variable frequency drive panel - duly internally wired and tested - parallel pumping software downloaded; Controller shall support either of BACNet / Lon / MODBUS protocols only; Variable Frequency Drive rating shall match the Secondary Pump Motor rating; all drives shall be installed in single VFD panel provided with ByPass arrangement - with entire assembly duly internally wired & tested; each VFD shall be provided with dedicated Isolator and included in the scope; Supply, installation, testing and commissioning of Differential Water Pressure Transmitters supplied and installed across selected AHU loads in the field and wired upto Pump Logic controller for integrated operation of the variable speed pumping system - cost to include supply and laying of 3C*1.5 sq mm armored signal cable upto Logic Controller. 700 GPM / 35 M WC (2 working + 1 stand by) Complete job as per technical specifications etc. as required.

3

-

-

... More
SITC of Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 230 V. 50 Cys. 900 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2, 3 core flexible wire with earthing

10

-

-

... More
Providing and arranging in position leatherette finish High back chair of Marvel of Godrej or equivalent. The seat and back shall be made up of Injection molded Plastic outer & inner and PU foam and MS ERW tube and upholstered with Leatherette. The armrest top should be moulded from polyurethane(PU) and mounted on to a drop lift adjustable. Chair shall be of 360° revolving type, upright-position locking, tilt tension adjustment with front pivot, seat/ back tilting ratio of 1:2, pneumatic height adjustment, High Pressure Die cast polished Aluminium pedestal and fitted with 5 nos. twin wheel castors.

2

-

-

... More
One 6 A x 5 pin 250 Volt universal socket outlet point controlled by one 6 A switch located on switch board.

600

-

-

... More
Supply, installation, testing and commissioning UL listed Quartzoid Bulb type Sprinkler Heads. (Standard Response): Pendent sprinkler with rosette plate 68°C

1405

-

-

... More
Providing and arranging in position Fabric finish stackable chair with Desklet & Arms of Scintilla of Godrej or equivalent. Seat and back shall be made of 12mm plywood upholstered with moulded foam and polyester fabric and covered with an injection-moulded polypropylene outer cover. Frame structure shall be made of powder coated finished MS ERW tubes legs with castores. The full desklet assembly should be flip-up type and should be made up of MS ERW tube and on which an scratch resistant tant abs desklet top.

64

-

-

... More
Providing and arranging in position 2 seater gang seating for visitors of Nano of Godrej or equivalent of sapproximate size 1100mm (L) x 570mm (D)x 400mm seat height and 650mm total height. Gang seater shall be made of powder coated MS ERW tube, chrome plated made of cold rolled steel, powder-coated perforated shell, chrome plated solid steel for differant elements.

246

-

-

... More
Providing material and labour for injecting Chemical emulsion for PRE - CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier on the top surface of plinth filling, inside junction of wall and floor, on top of damp proof course (DPC) or on masonry at level of plinth filling as per IS 6313 (Part-2)-1981 using chemical like chloropyripos emulsifiable, Biflex TC, lindane (IS 8944-1978) 20EC mixed with water in 1:19 ratio (1 liter chemical : 19 liters of water). The emulsion shall mentioned below, all as per specification and directions of Engineer-in-charge. Plinth area in plan at GF shall only be measured (for akk below specified steps) and paid. A guarantee bond of 10 years shall be furnished. A1) Bottom surface and the sides of the excavation made for masonry foundations at the rate of 4 liters/sqm (wherever applicable) A2) At the rate of 7.5 liter/ sqm to the backfill at the depth of 500mm below the original ground level. The soil in the immediate contact with the vertical surface of RCC column/ Masonry shall be treated. B) Top surface of the plinth filling including damp proof courses at the rate of 5 liter/sqm of internal plinth area etc. complete. C) At the rate of 7.5 liter/ sqm to the internal vertical surface from original Ground level to top of the earth filled in the plinth. D) At the rate of 7.5 liter/ sqm to the external vertical surface below finished Ground level to the full depth of the filling complete. E) 1 liter / linear meter along the junction of wall and floor at all stages.

9223

-

-

... More
Supply, Installation, Testing and Commissioning of Call / Cancel button The module should consist of finder / reassurance light with membrane keypad includes call button with Nurse symbol, cancel button (green). The button must have antimicrobial coating on surface and confims to VDE 0834.

10

-

-

... More
Providing material and labour for laying Plain cement concrete 1:3:6 (1- Cement : 3- Coarse sand : 6- crushed stone aggregates 20 mm nominal size) in Foundation and Plinth including cost of formwork, compacting, finishing, curing etc complete for all level, all height/ depth as directed by engineer in charge.

50

-

-

... More
Supply, Installation, testing and commissioning of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 150 x 100 made out of 2 mm thick perforated type

250

-

-

... More
Supply & Installation at fixing of resing bonded slab & with company bonded black glass tissue faced for False Ceiling Insulation as per detail specifications - 50mm

10

-

-

... More
Providing following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge. (8) Modem Jack for Computer Open RJ-45.

641

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 250mm dia.

1

-

-

... More
Providing material and labour for placing in position 80 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.

100

-

-

... More
Ceiling Hanging Providng and fixing of Modular Signages using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. Internal graphics to be made of 3M vinyl printed with Hp latex 3rd Gen Eco friendly non toxic inks with UV lamination and 2 year print warranty. Sign panel shall be finished with anti-reflex cover 1mm thick with one side Matt and other side Glossy finish. Polypropylene (PP) End caps which can be fixed to the extrusion with the help of screws. Panels shall be clicked on to the end caps. Aluminium framing shall be suspended from ceiling with suspension clips and cable (SS 304) with adjustable arrangement and signage panel shall be laid on aluminium framing as per manufacturer's specification. Rate shall be inclusive of total modular signage system for all level, all height etc complete as directed by engineer in charge. Sampe shall be approved before execution and mockup shall be done with approved sample for 2 to 3 number of signage.

34

-

-

... More
450 x 105 mm

20

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 500 CFM

22

-

-

... More
Providing material and labour for fixing powder coated inbuilt flush handle (without lock) of approved make of required capacity including all required accessories like nib, counter plate etc as per approved manufacturer recomendatation for aluminium sliding window with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

50

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Exposed to Atmosphere Closed Cell Nitrile Rubber GC bonded and above it 2 layers of UV paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and above it 2 layers of UV paint shall be applied , over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 50 mm dia.(32 mm thick insulation)

60

-

-

... More
Fix Louvers and Fins (made out of Aluminium Section) Providing, fixing, designing aluminium fixed louver of any type of louver section of approved make having minimum 50 micron polyster powder coating on all the surfaces of approved shade, texture & make as per manufacturer's specifications. Contractor shall submit the shop drawing for louver/ fins based on concept design/ drawing and as per elevation. Aluminium louver section shall be fixed on aluminium framing/ carrier/ panel/ GI clip and necessary sub structure with required fastners, hardware as per approved shop drawing etc complete for all floor, all height including scaffolding as directed by engineer in charge. Louver, framing and sub structure shall be in proper line, level and plumb. Necessary MS work shall be paid in relevant tender item.

100

-

-

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. as per technical specification etc. as required.

245

-

-

... More
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

60

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 500 CFM

1

-

-

... More
Providing and arranging in position Blood bank chair and make connection with required service. Chair shall be as per approved sample.

4

-

-

... More
01-CIVIL WORKS Sec.1.0 Earth work Providing material and labour, machinery for Excavation of foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in the campus for all lead, all lift/ depth and back filling foundations, the trenches, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.

17501

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 13100 CFM / 40mm Static Pressure for Washing, Drying & Press

1

-

-

... More
Data Networking - Fiber Optic Cable and Components Supplying, installation, testing and commissioning of outdoor 12 core armoured single mode fiber optic cable for outdoor connectivity where ever required in prelaid conduits / RCC hume pipes/HDPE/DWC, whichever maybe available etc. as per technical specification etc. as required.

450

-

-

... More
CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 50 mm dia.

44

-

-

... More
Providing and fixing bubble seal gasket of reddiplex, lorient or equivalent for door of any material made out of 5mm thick silicon having self adhesive fixing arrangement of approved shade and colour etc complete as per approved sample and as directed by engineer In charge.

50

-

-

... More
Providing, fixing, testing & commissioning UL listed SS corrugated braided Flexible pipe, nominal Inlet by outlet 1"x ½" with required accessories to complete the installation: Size: 1000mm

1

-

-

... More
Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. f) For 65mm dia pipes - 25mm x 76mm Nitrile Rubber Plain Tubing

120

-

-

... More
Providing material and labour for laying 8 to 10mm thick, double charged Vitrified tiles of size upto 600mm (of any shade glossy, matt or satin finsh) of approved make, shade and finish as approved by Architect/ EIC for all floors/ any height/ any levels etc in wall tile, dado, risers of steps, jambs as per drawings. Wall tile is to be fixed over 10 to 12 mm thick smooth finish plaster in cement mortar 1:3 (1 cement : 3 coarse sand) and fixed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including provision of groove, grouting of joints, finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Grouting and backing coat plaster shall be paid in relevant tender item. Sample and mockup shall be approvd procurement of material.

11247

-

-

... More
One light point controlled by two, two way 6 A switch

20

-

-

... More
TYPE-3 Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 24 # 10/100/1000Tx ports, minimum 2 SFP+ ports as per technical specification etc. as required.

4

-

-

... More
Providing material and labour for laying 20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.

500

-

-

... More
Providing & fixing C.P. Bath Spout with all nuts, washer complete as per of approved Quality and conforming to Manufacturers Standards. Work to be completed to the satisfaction of the Engineer-In-Charge. Make: Jaquar-FLR-SPJ-CHR-5429G or Equivalent of the same make.

77

-

-

... More
Wooden veneer ceiling Providing and fixing ply + veneer false ceiling on GI framing system for false ceiling work as per drawing and as following. 1) GL framing system which includes Perimeter Channel is fixed along the perimeter of existing wall/ partition with the help of screws at 600mm centers. Ceiling Angle is suspended at up to suitable height as per site conditions by fixing it to the soffit Cleat and Rawl Plug to creating grid. Intermediate channel is fixed to the Ceiling Angle with 2 Nos of 4.2x13 metal to metal screw. The Ceiling Section is then fixed to the Intermediate Channel with the help of Connecting Clip and in direction perpendicular to the Intermediate channel. All framing materials shall be of GI (IS513), YS-300Mpa, Finish-Galvanized 150GSM (IS 277). 2) 12mm backing play wood shall be 303 BWR grade of approved make shall be fixed on both side of MS framing of false ceiling work with SS screws. 3) 4mm thick teak veneer shall be fixed on ply with adhesive, hardware etc complete. 4) Wooden Beading shall be applied on all the sides of the panels of required size. 5) All exposed surface of wooden shall be lacquer polished of approved make, shade and texture. Actual area of veneer surface shall be measured and paid in sqmt without considering any wastage. Contractor shall get the sample of all material approved by Architect/ Engineer-in-charge.

50

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: 17.7.2 White Vitreous China Wash Basin size 630x450 mm with a single 15mm C.P. brass pillar tap

144

-

-

... More
Sec.11.0 Painting works White washing with lime on wall and ceiling surface (two coats) to give an even shade including thoroughly booming the surface to remove all dirt, dust; mortar drops and other foreign matter etc complete for all floors, all heights, all level as directed by Engineer Incharge.

9021

-

-

... More
Sec.2.0 Sanitary Installations Providing & fixing Divyang toilet set with European Closet (P Trap) & wall mount wash basin & all divyang requirements with dual flush tank, seat & cover (heavy duty) with C.P. brass hinges,including WC connector of 110mm inlet x 110mm outlet, connecting the same with soil pipe using appropriate solvent cement, C.I. Brackets for wall mounting the basin, 32mm CP waste Coupling, 32mm size CP bottle trap, CP brass Spatula Faucet, etc. all Internal fittings complete with S.S grab rails etc. rubber buffers, C.P nuts, bolts etc making holes in walls & floors, & finishing for ready to use.The rate includes all necessary connection charges as per product detail to the satisfaction and as directed by the Engineer-in-charge.

24

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 40 mm dia.(32 mm thick insulation)

300

-

-

... More
Providing material and labour for fixing 6mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.

1416

-

-

... More
Providing material and labour for Fixing of Mineral Fibre Suspended Ceiling System with Bevelled Tegular edge hygienic tile with grove (Bioguard) with 15mm Exposed grid. The tiles should have Humidity Resistance (RH) of 95%, Light Reflectance 90%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size of 600x600 x minimum 15mm with Anti Microbial coating on the face of the tile. The tile shall be laid on any type of grid system (Silhouette/ superfine/ select grid system of Armstrong) with 15mm white flanges incorporating a 6mm central reveal in white/ black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/M2 & minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with suspension system of same make. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres. SUSPENSION SYSTEM accessories shall be of same make and consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length, thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8mm thick, galvanised spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner.Contractor shall provide 0 year warranty against Tile & Grid system used together. Installation shall be done by approved applicatior of manufacturer all floors/ all heights/ all levels including scaffolding etc as directed by Engineer in charge.

50

-

-

... More
Providing and arranging in position cafe chair of UNWIND of Godrej or equivalent. Chair shall be made of MS Powder Coated (50 micron) Understructure (Without Arms) and the seat and back are made of injection moulded high impact strenght polypropylene polymer compound with indoor graade UV Resistance. The Shoes are made of high impact strenght polypropylene polymer compond with indoor grad UV Resistance and pressed fitted with tubular fram. Approximate size of chair is 520mm (W) x 550 mm (D) x 850mm & 450mm (H).

63

-

-

... More
150 x 105 mm

60

-

-

... More
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (b) RG – 6.

630

-

-

... More
Providing material and labour for fixing set of dead lock of approved make with 50mm backseat, 20mm square for end with 72 mm centers including strike plate in satin stainless steel finish as per DIN 18251-1, grade 2 and prepared for euro profile cylinder (EPC) including strike plate and EPC length 60/70 mm standard Euro profile Pin Cylinder/ Half pin cylinder with both side key/ one side key one side knob operation with one pair of SS 316 grade Escutcheons (key hole plate) for wooden/ aluminium/ metal doors with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys.

253

-

-

... More
Providing and fixing C.P. brass Wall Mixer with provision For overhead shower with 115mm Long Bend pipe on upper side, connecting legs & wall flanges, complete as per approved make and as directed by the Engineer-in-charge.

77

-

-

... More
Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections. A Conductor Size 0.5 mm. (b) Armoured. (Jelly Filled) (4) One Hundred Pairs.

150

-

-

... More
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 40 mm dia.

50

-

-

... More
Curtin in ICU Providing and fixing Cubical track system made of Aluminium Alloy of Box Size 1.7 x 20 x 25 mm with 50-60 microns thick powder coating in white color finish. Tracks are bendable to a radius of 250 mm at 90 degree to cover the whole bed. Aluminium track section shall be rigid high grade and with free – running roller wheel (not slides) and curtain hooks.

828

-

-

... More
Earth wire/strips : Supply and laying cu. earthing required size strips for interconnecting the earthing stations, panels, DB's etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with : a) Fixing accessories. b) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 25 x 3 mm/ 32X6mm / 50x6mm CU. strip/ 38x6 Cu earth link

2890

-

-

... More
Supplying, assembling, grouting, levelling, installation, Connecting testing and commissioning of D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement. Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 4 SPMCB as outgoing per phase (i.e. 8 way TPN D.B.) with 8 way PPI kit

52

-

-

... More
Providing and placing in position Examination couch of average size (L)1976 mm X (W)560 mm X (H) 810mm of Revive of Godrej or equivalent with following specification - 1) Base frame - ERW tube as per IS - 7138 - avarage size - 30mm x 30mm x 1.6 mm 2) 3 No bottom cabinate with 3 drawer at top line. Cabinate are made out of 1.0 mm thick CRCA sheet with recessed plastic handle, lock and door latch. Drawers are made out of 1.0 mm thick CRCA sheet with recessed plastic handle and double extention ball slide. 3) 12mm thick mattress integrated with top platform with adujestable head rest upto 30° angle and made out of integrated PU form upholstered with leatherite and strenthen with ply at bottom of platform. 4) SS 304 grade tissue roll holder provision. 5) Leveler - provide at base to compansate the un-even flooring made out of plastic with metal insert. 6) Inbuilt step stool/ Foot step - made out of 1.0 mm thick CRCA sheet with recessed plastic handle and can be slide In and Out on the ball slide for the use. 7) BP Aparatus Holder Tray with adjustable knob - 1.0 mm thick CRCA shaeet. All metal work shall be finished with Anti Microbial and epoxy polyster powder coating of white colour as per RAL shade.

34

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B GROUND FLOOR HVAC PANEL As per Single line diagram

1

-

-

... More
Providing and mixing Migratory Corrosion Admixture POLYALK CP 293 having Specific Gravity 1.01 to 1.04, pH value (Minimum 9.50) shall be alkaline in nature and having bipolar concrete penetrating corrosion inhibiting properties, inhabitor shall be non-nitrite based & have the ability to provide corrosion protection to both anodic and cathodic sites on the steel surface, inhibitor-steel complex shall formed polydentate complexes, having more than one bond with steel per molecule of inhibitor, with steel surface to promote proper film formation with enhenced bond to steel, inhibiting the electro-chemical corrosion reaction, inhibitor shall not have any adverse effect on concrete compressive strength, inhibitor shall have a corrosion rate of zero coulombs per ASTM-G109-2005, admixture shall be conforming to IS 9103 and in liquid form at the rate of 3Kg per one cubic meter volume of concrete admixture shall be added to the water, during mixing of cement, sand & aggregates and at the same rate admixture shall be added in case of Ready Mix Concrete at plant site, mixing of admixture during mixing of cement, sand and aggregates OR at work site the admixture shall be added in Concrete Transit Mixer before pumping / placing of concrete etc. complete.

25

-

-

... More
63 A DP ELCB (30mA)

3

-

-

... More
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 128 MB RAM & 64 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Fire Fighting Ststem - as per IO Summary and as per technical specification etc. as required.

1

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

20

-

-

... More
Supply, Installation, Testing and Commissioning of Pull cord, The Module should consist of finder / reassurance light with 2 mters pull cord with the grip and nurse symbol on it, with mounting frame for srew free installation.

10

-

-

... More
6/16A x 250 Volt switched socket outlet point for AC with 4 sq.mm wire for phase and neutral & 2.5 sq.mm earth wire.

21

-

-

... More
LEVEL SENSORS: Supplying & erecting approved make Automatic liquid level controller 6A.as per instruction of Engineer in charge on site complete with wiring connection with existing wires , with copper conductor from pump to upper and lower tank.

18

-

-

... More
CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 65 mm dia.

33

-

-

... More
Floor Directory Signage Providng and fixing of Modular Signages (removable) using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. For Flat panels, plotter cut vinyl letters to pasted and for sliding profile print to be made of 3M vinyl printed with Hp latex 3rd Gen Eco friendly non toxic inks with UV lamination and 2 year print warranty. Sign panel shall be finished with anti-reflex cover 1mm thick with one side Matt and other side Glossy finish. Polypropylene (PP) End caps which can be fixed to the extrusion with the help of screws. Panels shall be clicked on to the end caps. Aluminium framing shall be fixed on surface with SS 304 screw and signage pabnel shall be laid on aluminium framing as per manufacturer's specification. Rate shall be inclusive of total modular signage system for all level, all height etc complete as directed by engineer in charge. Sampe shall be approved before execution and mockup shall be done with approved sample for 2 to 3 number of signage. (Measurement : Actual area for directory signage shall be considered for payment.)

216

-

-

... More
Supplying, installation, testing and commissioning of 10G SFP+ Single mode transceiver, 1310nm, 2Km, LC connector, inclusive of any hardware such as modules for populating SM-LC transceivers as per technical specification etc. as required.

14

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for UPS's (06 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B UPS POWER OUTGOING PANEL As per Single line diagram

1

-

-

... More
SITC of 40 A FP MCB

9

-

-

... More
Garden Soil Filling Providing material and labour for Filling mixture of good quality garden soil obtained from outside for all lead and lift with farm yard manure and pesticides in exacavated tree pit, tree pit, shrub area including watering, ramming well, consolidating, compacting and dressing etc. complete, as directed by engineer in charge. Excavation shall be paid in revevant tender item.

500

-

-

... More
Providing material and labour for fixing External trim with design lever handle of approved make suiting the panic bar for fire and smoke check doors for max. 60mm thick door prepared for half euro profile cylinder and in Silver finish with necessary fittings etc. complete for all floor all height as recommended by manufacturer and as directed by Engineer in Charge.

9

-

-

... More
SITC of 32 A FP MCB

76

-

-

... More
WATER COOLERS: Supplying and erecting water filter cum purifier with ultra violate technology. (Aquaguard / waterdoc model or equivalent symphony/ crystal/videocon model)

47

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-D HVAC PANEL As per Single line diagram

1

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.2 - 1620 (20mm OD) pipe

95

-

-

... More
Providing and arranging in position 3 seater gang seating for visitors of Nano of Godrej or equivalent of sapproximate size 1630mm (L) x 570mm (D)x 400mm seat height and 650mm total height. Gang seater shall be made of powder coated MS ERW tube, chrome plated made of cold rolled steel, powder-coated perforated shell, chrome plated solid steel for differant elements.

537

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-D POWER PANEL As per Single line diagram

1

-

-

... More
SITC of of 3 compatement 225 mm x 38 mm, 1.6mm thick, under floor metal trunking/race way with all accessories made out of hot dip pre galvanized metal coated steel sheet.

30

-

-

... More
Supply, installation, testing and commissioning UL listed Quartzoid Bulb type Sprinkler Heads. (Standard Response): Upright Sprinkler 68°C standard response

1405

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. for Chiller Units Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.

1

-

-

... More
Providing and Fixing SS 304 Grade Satin Finish 1.8 mm Thickness Aldrops of 16 mm dia x 250 mm including 3 nos. fixing Bracket and 1 no. locking bracket of approved make with necessary MS nickle Plating Bolts etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

3

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 32mm dia.

4

-

-

... More
TYPE-4 Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 48 # 10/100/1000Tx ports, all 48 ports shall be capable of providing PoE+ as per 802.3at, minimum 2 SFP+ ports. as per technical specification etc. as required.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Wireless indoor Access Point supporting Dual band with 802.11a/n/ac (5 GHz) and 802.11g/n (2.4GHz) concurrent operation with MIMO support 3x3, 3 spatial streams, One 10/100/1000 BASE-TX auto-sensing (RJ45) PoE port, as per technical specification etc. as required.

12

-

-

... More
Providing and placing in position personal locker of size 380mm (W) x 450mm (D) x 300mm (H) of Gorej or equivalent made with rigid knock down construction. 6 no of Locker unit shall be stacked in one height. Add-on units shall be stacked width wise to form bank of lockers having common side panel. Lockers shall be made out of CRCA sheet and finished with epoxy polyester powder coated to the thickness of 50 microns. Locker shall be with 10 lever cam lock, handle, lable holder and ventilation.

366

-

-

... More
Sec.3.0 Centering & Form works Providing material and labour for formwork for exposed concrete surfaces (Only extra addition cost on normal shutering) (vertical or horizontal surface) in smooth finish, desired pattern and size as per drawing and specifications, including rendering with white cement and grey cement, using laminated shuttering plywood, for vertical and steel or laminated plywood shuttering for horizontal surfaces for all types RCC elements like slabs, walls, columns, beams, folded staircase (all sides), sill, coping, lintels, jambs, beam hunching, vertical fins, pardi etc. including neat cleaning the exposed concrete surface, as directed by the engineer-in-charge. In case of round window opening in exposed RCC wall, for payment of expose shuttering opening cutout shall not be deducted (both side). Rate shall be applicable for all floors, all levels, all places and all shapes. The contractor shall submit shuttering pattern including tie-rod hole position based on architectural conceptual drawings. (Same kind of shuttering material should be only used for standard and residual sizes.) Tie-rod hole shall be filled with polymer mortar/ polymer concrete as per manufacturer's specification.

200

-

-

... More
Providing material and labour for fixing SS 304 satin finished set of narrow style dead lock of approved make with 25mm /35 mm set back necessary euro profile pin cylindrical lock 60/ 70 mm for Key and or knob operation and one pair of SS 316 grade Escutcheons (key hole plate) for aluminium door with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys.

253

-

-

... More
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for all Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.

13824

-

-

... More
Supply, installation, testing and commissioning of hand held portable operator terminals.(POT) touch screen type, shall be able to view graphs , alarms , parameters etc These shall be required if the Controllers and Integration Units do not have a built in keypad on the facia . With required connectors etc. - 4inch. as per technical specification etc. as required.

1

-

-

... More
Dismentaling tiled of stone floors/ wall tiles laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.

20

-

-

... More
Sec.13.0 Demolition & Dismantling Work Demolition including stacking of serviceable materials and disposal or unserviceable materials at nonobjectionable place with all leads and lifts including cutting the reinforcement, and finishing the broken surfaces to match with the surroundings etc. complete : RCC Works.

20

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.1 - 1216 (16mm OD) pipe

85

-

-

... More
Supplying, installation, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 3 feet as per technical specification etc. as required.

439

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for Access Control System . as per technical specification etc. as required.

1

-

-

... More
Providing material and labour for laying in position Ready Mixed M-35 grade concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.

5728

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Fresh Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 10500 CFM / 40mm Static Pressure for Washing, Drying & Press

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 125 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter sections with MERV 12 filter, MERV 16 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 6R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 3600 CFM / 8.57 TR With 6.0 kW Strip Heaters & Humidistate For O.T - 4 Second Floor

1

-

-

... More
Providing material and labour for fixing SS 316 grade handles 150mm long D shape hollow tube handle of approved make with both end bracket with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

10

-

-

... More
Providing material and labour for laying controlled cement concrete M-30 produced in batch mix machine, using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work for all elements, all floors, any heights/ depths, any lead and lift including cost of formwork, compacting, finishing, curing but excluding the cost of reinforcement etc complete as directed by engineer in charge.

25

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 1825 cfm, external static 50 mmwg Exhaust air fan - 1750 cfm, external static 50 mmwg

1

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Actuator

21

-

-

... More
Providing material and labour for laying machined cut average 25mm thick River wash finish Green Kotah stone of size 1500mm of approved quality, selected and sorted for uniform color & texture, in floor, otta, tread, riser, ramp etc. of specified size as per design normal pattern (straight or staggered joint with square or rectangular shaped stone) and drawings. Kota stone is to be laid over cement mortar 1:6 bedding of average 20 mm thickness with keeping groove (upto 10mm wide), filling the groove with cement mortar in 1:2 (1 cement : 2 sand) with matching pigment, in 5mm less thickness of kota stone, and finishing including curing and cleaning with wire brush to remove excess cement on the sides of stone, pencil sharped exposed edges having polishing up to the satisfaction of the Architect & engineer in charge etc. complete for all places/ all levels/ all heights. Sample and mockup shall be approvd procurement of material.

232

-

-

... More
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 90 mm dia.

20

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / Hot Water multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built 2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with "Y" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 300 CFM

1

-

-

... More
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required. as per technical specification etc. as required.

28

-

-

... More
Providing and arranging in position FIXED SS TOP SQUARE STOOL of Godrej or equivalent. overall dimension of 420(l) x 420(w) x 515mm (h). Top should be made of SS 304 sheet with buffed matt finish. MS square flat tube of section 25 x 25mm with thickness of 2mm should be used. Thermosetting epoxy polyester powder coating must be done for all MS parts. Neoprene shoes should be provided at the base of legs.

330

-

-

... More
Supplying, installation, testing and commissioning of Client PC - Industry standard Intel based platform computer system. Intel Core i7 latest generation, 4 GB of RAM DDR3 ,1 TB SATA II hard drive for OS and VMS applications, NVidia card 1 GB graphics card , 1600 x 1200 or higher screen resolution, 1 X 1000Mbps ethernet network interface card ,16x DVD+/- RW Drive alongwith appropriate licenced Operating System, licenced applications suites from OEM and application licences as per the technical specifications etc. as required.

1

-

-

... More
Providing material and labour for fixing SS 316 grade push-pull pair of handle of size 300 mm long x 22 mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified.

211

-

-

... More
Providing material and labour for fixing powder coated two point lock with mortise handle (without lock) of approved make with heavy gear mechanism of required capacity including all required accessories like handle, fork, connector, extensior, polyamide, locking point, corner transmission and striker etc as per approved manufacturer recomendatation for aluminium casement door and window (top hung or side hung) with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

184

-

-

... More
SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 10 Sq.mm x 4C CU. Cable

28

-

-

... More
Providing material and labour for fixing in position PVC pipe sleeves of 160mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location).

50

-

-

... More
ELEVATOR FOR BUILDING - G + 2 Supplying, Erecting, Testing & Commissioning the passenger / stretcher lift having following main features: 20 passengers . G + 2 with Rated Speed of 1.5 m/sec - 1.75 m/sec with micro proce/PLC control and ACVVVF. drive, Duplex Control, Machine Room Less (MRL) - PREMIUM CATEGEROY Make : OTIS, Mitshubishi & Schindler Only (Joint Venture will not be allowed) [1] GEAR LESS LIFT DRIVE comprising of High Starting torque Lift duty 3 phase 440 V A. C. Permanent magnetic synchronous motor of proper rating with high efficiency shall be used. [2] Micro processor based / PLC, ACVVF, vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full collective selective operation hall call demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and phase reversal relay and safety controls. [3] Car with M S platform with bracings of adequate size and to sustain the impact load cabin + passenger with safety factor of fire for steel and side panels of Stainless steel of sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED ceiling lights. Car flooring shall be of anti skid PVC/Granite with choice of colour of engineer in charge. Car doors shall be of stainless steel grade 304, hairline finish with centre opening / telescopic automatic doors. Car panel will also be S.S. 304 finished with emergency stop device, mechanical door safety device, facility of auto/ attended mode. All car panel buttons and all floor switches must be with brail language as per lift act. S.S. Hand rail at 900 mm height for all three side. Door must be clear 900 mm centre openable. [4] All landing doors shall be fully automatic centre opening/ telescopic opening made of hairline finish steel grade of 304 with key holes and infrared curtains with Unlocking facility from outside. [5] Appropriate battery operated emergency light in the car along with alarm switch shall be provided. [6] Digital scrolling indicator system for up-down arrow along with floor position indicator shall be provided inside the car and at all floors. [7] Full height infra red curtain with multiple criss / crossing light beams shall be provided. [8] Automatic Rescue Device (ARD) shall be provided accordingly of passenger capacity. [9] Audio visual indication in the lift car showing over loading shall be provided such that doors kept open till excess load is removed. [10] Spring buffers/PU Buffers shall be provided. [11] Car fan with automatic sleep timer shall be provided. [12] Voice annunciater with suitable music shall be provided in lift car. [13] Self diagnostics system for operational and safety parameters shall be provided in control panel. [14] Mechanical over speed governor, door key holes in the floor doors, fireman switch shall be provided. [15] Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the Contractor, along with the other steel structure works, foundations for the machine etc… [16] In the hoist way fascia plate shall be provided without any extra cost, where ever required as / if directed by engineer in charge. [17] Permanent wiring in lift machine room and lift well with proper numbers of light points, with fixtures, exhaust fan and plug points shall be provided by the agency. Power supply of 3 phase 440 V shall be made available by department in lift machine room. [18] Any civil/ electrical works for additional and alteration in lift shaft and machine room related to erection of lift shall be made by contractor without any extra cost.(granite/marble fixing around all landing door openings are in contractors scope.) [19] Agency has to provide all working drawings and documents and liaison services for obtaining all necessary permission from lift inspector and other authorities. [20] As per statutory requirement of Got. Of Gujarat lift & escalator act 2000, contractor has to provide 1. Car top safety barricade 2. Push & talk communication system. 3. Fireman's switch operation at Ground Floor

2

-

-

... More
Providing and fixing concelled type Auto drop down seal of PR Arch Solutions or CCE (Itly) or approved for door shutter of size 28mm x 13mm made out of aluminium with silicon and fixed at bottom of shutter as per approved sample and as directed by engineer in charge.

50

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 300 CFM

1

-

-

... More
Providing material and labour for fixing of expansion joint system for 100mm wide gap of approved make related with External wall joint location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner, with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Rate shall be inclusive of polyester powder coating of approved shade and make. Expansion joint system shall be as approved for all floor all level including scafolding etc complete as dircted by Engineer in charge.

30

-

-

... More
Extra for providing material and labour for Grouting the joints of any type of flooring tiles of Size upto 600mm having joints of 3mm width and in full depth, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade and approved make (0.10 kg of hardener and 0.20 kg of resin per kg), including filling/ grouting and finishing complete as per direction of Engineer-in-charge.

33851

-

-

... More
Providing and laying rubble soling in plinth and sub-base of road, compacted thickness specified as following, using specified size of hard stones for average 150mm thick soling, filling, covering and leveling the surface with a layer of earth after filling the voids (upto 25%) with sand, smaller sized black trap stones 20-40mm, 40-63mm, 63-90, 90-150mm size of stone/metals or stone chips, including watering, ramming well and compacting or consolidating each layer by static roller/ vibratory roller of required capacity as directed by Engineer-in charge.

1475

-

-

... More
Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections. A Conductor Size 0.5 mm, Armoured. (Jelly Filled), Two Hundred Pairs.

150

-

-

... More
Supply, Installation, Testing and Commissioning of System Switch / Ward Controller: forms a decentralised communications node for exchanging data between the connected system devices and the rest of the communications system. It should have , - 1 x RJ45 socket, 100Mb IP Uplink Port galvanically isolated conformant with EN 60950 and VDE 0834 - 7 x RJ45 sockets, each with a 100Mb POE port - 1 x RJ45 socket, 100Mb IP POE Port (IEEE802.3 100BaseTX) for connecting Staff Room Devices - 2 x RJ45 sockets for connecting the external data bus including 230VAC / 24DC , 5 A power supply.

2

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 250mm dia.

5

-

-

... More
Supplying, installation, testing and commissioning of Networking enclosure - Floor mounted, 19" mounting frame, usable height 24U, 600mmW x 600mmD etc. as per technical specification etc. as required.

3

-

-

... More
SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 70 Sq.mm x 3.5C Al. Cable

18

-

-

... More
ELW 14.00 Internal Wiring WITH MODULAR TYPE SWITCHES Wiring of points to be done in open/concealed manner in 25 mm dia medium guage Rigid PVC FRLS pipe. Wiring shall be done with FRLS type copper flexible wire of 650V/1100V. Separate pipe should be taken for circuit mains. Nos of ciruit of the same phases may be taken in same conduit .The circuit shall be laid in 25/40 mm dia medium guage rigid PVC FRLS pipe.The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to the batten holder / angle holder / connector / ceiling rose all inclusive except sub panel / Dist board. The wiring shall be done as per relevant prevailing standard. The looping of the wiring should be done in the switch boxes or light and fan point outlet boxes to avoid the junction boxes. The junction boxes and switch boxes for the ceiling light point, fan point etc shall be minimum 60/75 deep. All the necessary jarry in brick plastered walls should be done with machine cutter only , also jarry should be filled with cement, sand and wire mesh as required, the material cost for rough finish shall be included in point rate.Whenever pipes are required to be laid in flooring shall be of.Wiring should be done as per distribtion details. Each circuit should have dedicated phase, neutral & earth wire. Wire sizes to be used as under For Light Points /fan point/ wall fan / 6A 3 Pin Plug - DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth - SB to on board Point - 1.5 sqmm for Phase & Neutral & Earth For 6A Plug point. - 1.5 sqmm for Phase, Neutral & Earth For 6/10/16A general purpose plug point - 2.5 sqmm for Phase, Neutral & 1.5 sqmm Earth For 16A plug point for A/C and Geyser - 4 Sqmm for Phase, Neutral & 2.5 sqmm Earth For 20/32A plug point - 6 sqmm for Phases, Neutral & 4 sqmm Earth No zarry will be allowed in expose brick work. The conduit shall be provided when the walls are under construction. The pipes in slab shall be laid before the slab is casted. One light point controlled by one single way 6 A switch.

1431

-

-

... More
Providing material and labour for laying average 25 mm thick machine cut polished Green kota stone slab of size upto 2.1mt length for riser of stair over 12 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. The rate shall be inclusive of making rebates of 10x10mm for forming the grooves between treads and risers with polishing inside the groove. Sample shall be approved before execution. Sample and mockup shall be approvd procurement of material.

60

-

-

... More
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 110 mm dia.

20

-

-

... More
Providing material and labour for fixing 6mm thick frame less mirror of approve make in any shape and sizes as per drawing. Mirror shall be fixed on 6mm thick cement bonded particle board (Bison panel) backing. Cement bonded particle board shall be fixed to wall with approved SS 304 fastener. All edges of glass shall be grinded (as required), cute corner and polished. Glass shall be fixed with silicon sealant/ 3M tape etc complete at all floors/ all levels/ all heights as directed by engineer in charge. Installed area of mirror shall be considered for payment without wastage.

141

-

-

... More
Providing material and labour for Excavation of foundation from 1.5 mt to 3.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in the campus for all lead, all lift/ depth and back filling foundations, the trenches, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.

17501

-

-

... More
Providing material and labour for laying machined cut average 25mm thick River wash finish Green Kotah stone of size upto 600mm of approved quality, selected and sorted for uniform color & texture, in floor, otta, tread, riser, ramp etc. of specified size as per design normal pattern (straight or staggered joint with square or rectangular shaped stone) and drawings. Kota stone is to be laid over cement mortar 1:6 bedding of average 20 mm thickness with keeping groove (upto 10mm wide), filling the groove with cement mortar in 1:2 (1 cement : 2 sand) with matching pigment, in 5mm less thickness of kota stone, and finishing including curing and cleaning with wire brush to remove excess cement on the sides of stone, chemphering of exposed edges having polishing up to the satisfaction of the Architect & engineer in charge etc. complete for all places/ all levels/ all heights. Sample and mockup shall be approvd procurement of material.

232

-

-

... More
“Providing & erecting approved make Card Personality Module (CPM) having following features “(A) EM proximity Card Reader Module [Low Frequency] “(B) Compatible with any COSEC Door Controllers and COSEC Reader CA “(C) Supports EM Proximity Card”

1

-

-

... More
Providing and fixing high quality 35 to 40 mm thick FRP water gully cover wothout frame of required size of 5 T capacity having the load tested as per BSEN 124, Is1726 & AASHTO M306 standards of approved make and shade. Gully cover shall be directely fixed on wall of RCC channel as per drawing and as directed by Engineer in charge. Actual installed area of cover shall be meaured for payment with out considering any wastage.

20

-

-

... More
WATER COOLERS: Supplying and erecting approved make water filter having outer body of tough polycarbonate with fitter cartridge having filter to trap micro elements with coupling suitable for erection on pipe line.

47

-

-

... More
Supply, Installation, Testing and Commissioining of IP based Networkable touch screen paging station for selection of zones, supervision of system status, setting of scheduled broadcasts with the following functions: Built-in monitoring loudspeaker, Detachable goose-neck microphone, LCD touchscreen display, Audio input as per technical specification etc. as required.

1

-

-

... More
Providing, fixing AUTO GLOW photo luminescent Signage's as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Fire Equipment: 4" x 12"

24

-

-

... More
16A /20A / 25A / 32 A DP ELCB (30mA)

207

-

-

... More
Providing and arranging in position Sloted angle storage rack of size 900mm x 450mm x 1800mm (5 panel rack to making 4 no of compartment) of Godrej or equivalent and made out of powder coated MS Amgel and CRCA sheet for compartment surface.

90

-

-

... More
Sec.8.0 HVAC Plant Room - Electrical Panel Supply, installation, testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction extendable panel, suitable for operation on 415 ±10% volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of suitable sized square tubular section and covered with CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 1000 Amps. capacity extensible type TPN Copper bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 KA for 1 sec., bottom base channel of section not less than 100mmX 50mmX 3mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bus bar to switch gears with required size of Copper. bus bars and inter-connection with solid copper conductor wires / aluminium strips, neutral links, including control wiring with 1.5sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted with the following switch gears as per drawing and technical specifications etc. complete as required. ( Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control). Including suitable connectivity for BMS and Remote Operation including providing sufficient number of potential free / auxiliary contacts. All outgoing shall be provided with Stop/Manual/ Auto/selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contact for Connections to Building Automation System. A separate set of CTs to be provided for BAS and wiring from CT’s and voltage transducers to be brought on to separate set of terminals. Incoming: 1 No.- 1250Amp. TP + N Air Circuit Breaker Horizontal Manual drawout type of fault breaking capacity 50kA (Ics=lcu =Icw for 1 sec. at 415V), impulse voltage (Uimp) 8KA, insulation voltage (Ui) 1000V, fitted with interlocked door, automatic safety shutters, 6NO + 6 NC auxilliary contacts, mechanical ON/OFF and service/ test/ isolated position indicators and frame earthing contact, conforming to IS-13947-2 1993 as amended up-to-date complete with following accessories Independent Electrical / manual spring closing mechanism - I set. Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection - I set. 3 Nos. Phase indication LED lamps with 2Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. 1 set - multifunction digital meter to read V, Amp, KW, KWH with 3 nos. resin cast CT's of 1250/5A class 1.0 accuracy and 15 VA burden. Shunt trip coil 220V A.C. Bus Bar : TPN Copper extensible type main bus bars of minimum of 1250 Amp capacity and auxiliary bus bar of suitable capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25 KA for 1 sec. Outgoings: 4 Nos. 315 Amp three pole microprocesser release, MCCB (Ics=Icu at 415 Volts) with O/L, S/C & built-in earth fault protection, and outgoing feeders to 4 Nos. 140 KW starter panel and outgoing feeders to 4 Nos. chilling unit compressor motor. The MCCB compartment shall contain : with folloxing accessories for each MCCB's 0 - 500 volts 96 x 96 sq mm digital voltmeter with selector switch. 0 - 400 amps 96 x 96 sq mm digital ammeter with 400/5 amps CT’s and selector switch Over voltage tripping mechanism for persistent voltage exceeding 110% of the rated voltage for more than 5 minutes. Phase indicating lamps, with toggle switches. TPN bus bars shall be of Aluminium and shall be sleeved. Phase bus bars shall be rated at 400 amps and neutral bus bar shall be of 50% capacity. Maximum density of aluminium bus bars for current carrying capacity shall be 1.4 amp per square mm. 4 Nos. 32 amps TPN MCCB 10 HP / 7.5 KW star delta starter, over load relay with built in single phasing protection and outgoing feeders to condenser water pump motors. Each of these compartment shall contain CT operated digital ammeter of 0- 32 amps range with selector switch, auto / manual / off selector switch auto / manual / off selector switch and an indicating lamp with MCB and toggle switch for ‘ON’ status of pump motors. 4 Nos. 100 amps TPN MCCB 40 HP / 30 kW and 4 Nos. outgoing feeders to Adjustable Frequency Drive (AFD) panel zone (B) and 4 Nos. outgoing feeders to secondary chilled water pump motors The compartments shall contain CT operated digital ammeter 0 - 100 amps range with selector switch and an indicating lamp with MCB and toggle switch for ‘ON’ status of pump motors. 4 Nos. 40 amps MCCB 15HP / 11 KW star delta starter, over load relay with built in single phasing protection and outgoing feeders to Primary Chilled Water pump motors. Each of these compartment shall contain CT operated digital ammeter of 0- 40 amps range with selector switch, auto / manual / off selector switch and an indicating lamp with MCB and toggle switch for ‘ON’ status of pump motors. 4 Nos. 40 amps MCCB - star delta starter with suitable 15HP / 11 kw motors / fan capacity, complete with contactors, overload protection relay, current sensing type single phase preventor, ON/OFF indications, push buttons, auto / manual / off selector switch, suitable Digital Ammeter with cast resin suitable rating CT's and all other accessories with suitable rating PVC insulated FRLS single core copper conductor cable etc. complete as required.(For Cooling Tower Fan motor) 1 No. - 160 Amp. TPN MCCB as spare 3 Nos. 63A TPN MCCB as spare Necessary cable alleys, space for spare switches, internal wiring, control wiring/cabling shall also be included. All switches and other components shall be motor duty rating. Note. MCCB’s shall be with Micro processor based release with communication port & of motor duty, suitable for 25 KA (ICS) fault current. HVAC PANEL AS ABOVE

1

-

-

... More
Providing material and labour for laying controlled cement concrete M-20 produced in batch mix machine using graded, black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work for all elements, all floors, any heights/ depths, any lead and lift including cost of formwork, compacting, finishing, curing but excluding the cost of reinforcement etc complete as directed by engineer in charge.

25

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised-PVC rain water pipes conforming to IS : 13592 (Type A), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe Bend - 150mm dia pipe

20

-

-

... More
SS letter sign: Providing, Making and fixing 200mm high SS 304 letter with back lited by LEDs/ SMD lightings behind the text made of 3/4" SS 304 channel (1mm thick) for signage in Gujarati, Hindi and English languages and the font style as approved sample or as per design and drawings. It shall be made from ISI Brushed S.S. 304 using Water jet / CNC cutting machine. It shall be fixed on the wall with chemical anchor fastener at any level any height. All Edges and corners shall be smoothened. Width of the letter shall as per the proportion of the word for depth 1". Stainless Steel Patti shall be argon welded. Duco paint of approved make, shade in required coat with necessary primer and putty shall be applied on external surface of letter. It shall be paid in as per alphabet no. In Gujarati/ Hindi language one letter shall considered with its contents (i.e. Kano, Matra etc.) i.e. 'chhi' letter in Guajarati shall be considered as one letter. Height of letters may vary + 3" shall be included in quoted rate. The rate shall be inclusive of scaffolding, drilling, adhesive material etc. complete for all heights.

90

-

-

... More
Providing and fixing white vitreous china sink for Sluice Room, Laboratory & Autopsy Room, with C.I. brackets, 40 mm PTMT waste coupling, 40mm PTMT bottle trap, complete, including painting of fittings and brackets, cutting and making good the wall wherever required as directed by Engineer. Sink for Sluice Rooms. Sink: Make: Cera – CATER 600 x 400 x 250 mm (660 x 460 x 250 mm including rim) Cat. No. S6010103; PTMT Waste Coupling - PolyTUF - 38/40 mm - 1003 (b); PTMT Bottle Trap - PolyTUF - 40mm - 1060.

15

-

-

... More
Providing and arranging in position MEDICINE TROLLEY of Godrej or equivalent. overall dimension is 902(L) X 532(B) X 915(H) mm. Top shelf & bottom shelf should be made of SS304 sheet with 1mm thickness & 1.2mm. Rest of the components like supporting legs, horizontal bar handle should be made of SS 304 pipe having dia 31.8, 12.7 mm respectively. The castors of high quality plastic injected molded & anti static having the dia of 125mm should be used.Handles made of SS 304 pipe having section of 16mm & thickness of 1.2mm should be used.

17

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 1050 cfm, external static 50 mmwg Exhaust air fan - 1750 cfm, external static 50 mmwg

1

-

-

... More
Providing and fixing stainless steel (Grade 316) Railing and baluster system of approved make stair railing, hand rail, bump rail, guard rail, with knock down system made of Hollow or solid secion i.e. tubes, square, flat, plates, bar etc with base plate Cover cap, finishing accessories, infilled holding brackets, fixing accessories etc. for any type of design, shape (plain/ curvature), size as per drawing. Railing shall be top mounted or side/ wall mounted. Railing shall be fixed with SS 316 grade anchor fastner of required size and as per fixing position of approved make. No Welding OR Fabrication shall be allowed at site. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Sample shall be approved before execution. Contractor shall arrange mock up of railing system (2 or 3 no) in required length as directed by Architact and Engineer in charge. Contractor shall protact railing system uptill handeling over the project.

6266

-

-

... More
FRP Recessed Man hole cover Providing and Fixing heavy duty double seal FRP Manhole cover with frame of 25MT capacity, in matching shade of surrounding pavement and design according to EN - 124:1994 of HP or equivalent of clear opening size of 600mm x 600mm and recesse depth 80mm, with client's logo etc. complete as approved by architect and as directed by engineer in charge. Frame shall be embaded in concrete of M25 grade and top level of frame shall be flush with road level. Frame and cover shall be with 4 number lifting key with proper lifting arrangement. Rate shall be inclusive of cover frame and concrete work. The rate includes carting upto any lead from store to site as per directed by engineer in charge.

20

-

-

... More
Providing and fixing PTMT grating of approved quality and colour: Rectangular type with openable circular lid: 150 mm nimnal size square 100 mm diameter of the inner hinged round grating.

397

-

-

... More
SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 150 Sq.mm x 3.5C Al. Cable

20

-

-

... More
Sec.15.0 General Development and Road works Box cutting the road surface to proper slope and camber for making a base for road work including removing the excavated stuff and depositing on the road side slope as directed upto 1 Km lead and all lift.

20

-

-

... More
Supplying, installation, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 7 feet as per technical specification etc. as required.

439

-

-

... More
Sec.3.0 Fire Detection & Alarm & Digital EVAC System Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Irrespective of whether or not mentioned in the boq, all necessary interfaces - such as hardware and software - for interconnecting all fire alarm panels at site shall be provided in the system(s). Ten Loop Panel

1

-

-

... More
Providing and arranging in position STRETCHER ON TROLLEY of Godrej or equivalent. overall dimensions 2000mm(L) X 660mm(W) X 825mm(H). The trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick ERW tube. hollder for stretcher should be made up of mild steel Castor should be of 200 mm dia, diagonal locking castor. stretcher should be made up of ERW tube of dia 25.4 mm and thickness 1.6 mm Top sheet should be made of CRCA sheet of thickness 1.2 mm with contour shape to accommodate patient. IV pole holder should be made of MS. All metal components should be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbial epoxy polyster powder coating. stretcher on trolley in knocked down construction. The manufacturer should compilant with ISO 9001, 14001, 13485, OHSAS 1800 and CE certification.

17

-

-

... More
ELW 19.00 UPS Supply, Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 20KVA UPS 3 ph in 3 ph out for balance load

2

-

-

... More
40 mm Dia.

175

-

-

... More
Wall projected Providng and fixing of Modular Signages using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. Internal graphics to be made of 3M vinyl printed with Hp latex 3rd Gen Eco friendly non toxic inks with UV lamination and 2 year print warranty. Sign panel shall be finished with anti-reflex cover 1mm thick with one side Matt and other side Glossy finish. Polypropylene (PP) End caps which can be fixed to the extrusion with the help of screws. Panels shall be clicked on to the end caps. Projection Bracket shall be of 3mm Aluminium extrusions having Anodized finish (same as framing). Projection Bracket shall be fixed on wall with SS 304 screw and signage panel shall be laid on aluminium framing as per manufacturer's specification. Rate shall be inclusive of total modular signage system for all level, all height etc complete as directed by engineer in charge. Sampe shall be approved before execution and mockup shall be done with approved sample for 2 to 3 number of signage.

12

-

-

... More
CABLE END TERMINATION AND CONNECTION Supply, fixing, connection, testing & commissioning of single compression brass cable glands and crimping type Bimetalic lugs / sockets with necessary tools and equipments as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes, if necessary, supply and fixing of extension busbar of same material on circuit breaker or panel board terminal / connector to connect more than one no. of parallel cables or to connect higher size cable to lower size unit. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh. 3C X 4 SQ. MM. CU XLPE CABLE

2

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-C UPS POWER PANEL As per Single line diagram

1

-

-

... More
Sec.6.0 Miscelleneous Works Supply, installation, testing & commissioning of Ceiling Mount Cassette type Exhaust Fan. - 200 CFM

12

-

-

... More
Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), vent cowl as approved and directed by the Engineer-in-charge. For 110 mm Dia pipe

14

-

-

... More
Providing & erecting approved make Application Software Platform for 500 User having following features “(A) With 100 Users “ (B) Expandable up to 500 Users with COSEC USER 100 “(C) Supports up to 16 Door Controller “(D) Basic Access Control Basic Time Attendance and Enrollment Management (E) Compatible with all COSEC Hardware “(F) Add Other COSEC software modules on requirement.

1

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts. 32mm dia.

8

-

-

... More
Supplying, installation, testing and commissioning of Laser Jet B/W Printer - A4 Size. as per technical specification etc. as required.

1

-

-

... More
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 10 Sq.mm x 4C CU. Cable

639

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank as per IS: 12701, marked with cover and suitable locking arrangement and making necessary holes for inlet, oultet, and overflow pipes but without fittings and the base support for tank. (Each tank of 5000 liters capacity)

150000

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. AUTO BALANCING VALVE complete with Flanges Nutbolts and Working parts 80mm dia.

11

-

-

... More
Providing and arranging in position work table with CPU hanger system and modesty panel of Enterprise 1500 of Godrej or equivalent of approximate size 1500 Width mm x 750 Depth mm x 725 Height mm with knock down construction system. Total assembly shall be maade of 25mm & 18mm thick prelaminated partical board of approved shade with PVC membrane pressed on it, PVC lipping at exposed edges, CRCA member and MS ERW tube finished epoxy polyster powder coating, Required hardware shall be provided i.e. wire management system, plastic cap for cable travel, leveler glide, handle, lock, sliding mechanisam etc.

133

-

-

... More
Providing material and labour for fixing 6mm thick Compact Sheet of any size, any shape, any color (single side, double side coloured), any texture of approved make and as per approved sample (approved by architect). Compact sheet shall be fixed in aluminium frame and shutter work with necessary cutting of sheet, provision of groove, filling of groove (both side) as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ adhesive tape/ screwing on the periphery of the sheet as per the required thickness etc. complete at all floors/ all levels/ all heights as per the drawing & directed by Engineer in charge. Cut edges of the compact sheet shall be provided with masking tape. Actual installed quantity shall be measured and paid.

1766

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. AUTO BALANCING VALVE complete with Flanges Nutbolts and Working parts 25mm dia.

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 6850 CFM / 14.10 TR For Pre Op Room and Corridor at Second Floor

1

-

-

... More
Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet

6230

-

-

... More
ELW 20.00 Exit sign SITC of Self contained single sided exit sign for wall / ceiling / pendant cantilever mounting with 3 W LED tube for Non maintained battery backup emergency lighting for 2 hours duration.Prolite make or approved equal in quality and design.

50

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 3175 cfm, external static 50 mmwg Exhaust air fan - 1750 cfm, external static 50 mmwg

2

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Fresh Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 2600 CFM / 40mm Static Pressure for OT Store

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-A LIGHTING+SMALL POWER PANEL As per Single line diagram

1

-

-

... More
SITC of approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame.ABS body with inbuilt lowers & square frame.

10

-

-

... More
SITC of Provide expanding firestop foam on both sides of wall, with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814, for horizontal/ vertical openings in floors / wall or slabs made of concrete/ masonry or Gypsum after passing service lines like cable trays or cables/cable bundlesThe system shall be UL listed & classified and product shall bear the UL and FM approval logo on the packing. The system shall be UL listed & classified and product shall bear the UL & FM approval logo on the packing. If none of UL test certificate comply with actual application, an EJ document (as per IFC Guidelines) prepared by a qualified personnel and based on nearest third party tested & approved systems like UL test certificates & in accordance with IFC guidelines shall be producted by manufacturer.Firestop installation shall be done by manufacturer's Accredited Firestop Speciality Contractor (HAFSC) and in accordance with manufacturer's guidelines and UL system test certificates or approved EJ document.

24

-

-

... More
Providing material and labour for laying approved quality average 18mm thick mirror polished Granite stone of approved shade in floor, otta in any pattern etc sizes upto 1200mm including average 20 mm thick cement mortar bedding in 1:6 laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as per satisfaction of Architect and as directed by Engineer in charge at all floors/ all levels/ all heights and all shapes. (Only finished work will be measured.) Sample and mockup shall be approvd procurement of material.

2577

-

-

... More
Providing material and labour for laying controlled cement concrete M-25 produced in batch mix machine, using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work for all elements, all floors, any heights/ depths, any lead and lift including cost of formwork, compacting, finishing, curing but excluding the cost of reinforcement etc complete as directed by engineer in charge.

25

-

-

... More
Providing material and labour for fixing of double shutter lead line door of average sizes 1500mm(W) x 2400mm(H) of make Pacific or equivalent make, with a 2mm Lead sheet, provision of lead glass as vision panel, with all Heavy duty hardware of make Geze, Dorma or equivalent make with following specification. Door Frame - The frame is size 143 x57 of 1.6mm thick GI sheet having polyester powder coating of 50 to 60 micron thickness. Frame shall be with 2mm thick lead sheet with and reinforced to support the load of the lead sheet. Frame shall be fixed with SS 304 grade anchor fastener (Min 3 No per side) of approved make and size. Door shutter - Door Shutter in 46 mm +2mm thick manufactured from 1.0mm GI sheets on both faces press formed, lock seam jointed at stile edges to form a double skin fully flush shell. Infilled rock wool insulation material to be provided for structural rigidity & additional reinforcements & sound Insulation with Honeycomb core infill for structurally flat surface & construction with 2 mm thick lead lining. The lead lining is located in the core of the door with other infill material. The internal construction of the door should be appropriate for all hardware fixtures and vision glass. Vision Panel - 10 mm thick Lead Line Glass. Hardware : Hinge: SS 304/316 grade heavy duty ball bearing hinge - 4 No/ shutter, 2 No Door Closer, Dead lock, push-pull pair of handle of size 300 mm long x 22 mm dia, 1.0 mm thick Kick plate, Flush bolt, Rate shall be inclusive of frame, shutter, vision glass (lead line glass), fastener, all hardware with installation for all floor all height etc complete as directed by engineer in charge. Out to out dimension of door with frame shall be measured for payment.

15

-

-

... More
Providing and fixing 120 min fire rated Mortise sash lock of Dorma 281a or equivalent with 70 mm Cylinder Thumb turn with Lever TH 126 CE marked for fire rated metal door of Dorma or equivalent with necessary fittings etc. complete as recommended by manufacturer and as directed by Engineer in Charge.

50

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 80mm dia.

1

-

-

... More
02.00 PLUMBING WORKS Sec.1.0 WATER SUPPLY Providing and fixing to wall and ceiling ISI Marked (Embossed) 100mm diameter of Medium Duty 'B' Class G.I. pipes as per IS: 1239, complete with cutting, threading, all fittings such as unions, bends, tees, etc, Teflon tape over threaded joints, Hilti anchor fasteners, G.I. threaded rods, double sided G.I. clamps, etc. including making good the wall and ceiling complete as directed by the Engineer-in-charge.

65

-

-

... More
Providing and fixing PTMT Bottle Trap for wash basin and sink, of approved quality and colour. 17.70.2: Bottle trap 38mm dia single piece moulded with height of 270mm, effective length of tail pipe 260mm from the center of the waste coupling, 77mm breadth with 25mm minimum water seal, weighing not less than 263 gms.

41

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 100 mm dia.(32 mm thick insulation)

260

-

-

... More
Providing material and labour for applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 7.5 kg/10sqm using mechanical means including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.

100

-

-

... More
Supply, Installation, Testing and Commissioning of Volume Controller, Built-in 24V DC forced relay, Selectable power : 120W, Frequency response of 100Hz- 20 KHz, 100V input voltage with required back box, as per technical specification etc. as required.

10

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 19 mm dia.(19 mm thick insulation)

650

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 40mm dia.

10

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 16.73 TR / 8050 CFM For Reception Waiting & Corridor at Ground Floor

1

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 80 mm dia.(32 mm thick insulation)

260

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.00 mm sheet

5

-

-

... More
M.S. Above Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / gaskets / Nut bolts etc., and laying on the surface including painting with one coat of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required: 50 mm dia

1208

-

-

... More
Curtain wall system for circular ramp area with single glass unit Designing, fabricating, testing, protection, installing and fixing in position curtain wall system (in circular shape) designed to with stand the wind pressure of site location confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure). The profile system is based on capped curtain wall design and glass is held all around by mechanical pressure plate and cap with microwave cured EPDM gaskets in all four sides of glazing, with necessary brackets of aluminium alloy of 6065 with three dimensional adjustment with serrations and serrated washers to arrest the wind load movement, SS 316 grade anchor bolts, screws and fasteners with non staining weather sealant and 1.5mm thk flashing sealed all around parameter inside and outside to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ. The system shall be designed for 3 barrier gasket system based on pressure equalization principle with drainage provision at all panel bottom & thermal break gasket barrier between pressure plate and aluminium grid work for improved thermal performance and weather performance, spandrel panel shall have pressure release & condensation drainage provisions, The system shall be able to accommodate building movements, thermal expansions resulting from surface temperatures of up to 80deg cel, temperature differential of 25 deg cel thermal expansions and the seismic movements without creating excessive stress. The system shall be designed to accommodate minimum 10mm vertical movement between floors. All metal joints in the wet area shall be with small joint sealant applied to ensure water tightness, so curtain wall system becomes water tight. The extruded aluminium sections of Alloy 6063 T5/ T6 and tolerances confirming to DIN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the visible surfaces shall have Super Durable polyester Powder coating finish as per manufacturer's specifications. The non visible aluminium surfaces shall have minimum chromatizing treatment. Glass shall be Single Glass, Heat strengthen and of required thickness as per thickness analysis report of approved manufacturer. After installation of total system, glass will not appear with waviness or sagging. The quote rate shall include all design, engineering & shop drawing prepared by contractor and approval from consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer in Charge. MS work shall be paid in relevant tender item.

10

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Fresh Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 5300 CFM / 40mm Static Pressure for Autoclave & ETO Plasma Area

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B SECOND FLOOR UPS PANEL As per Single line diagram

1

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 25 mm dia.(19 mm thick insulation)

930

-

-

... More
Sec.9.0 Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. Only Opearation Cost During DLP

1

-

-

... More
ELW 9.00 CABLE TRENCH Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 240 Sq.mm x 3.5C Al. Cable

70

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. NON - RETURN VALVE with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. 150 mm dia.

3

-

-

... More
Supply, installation, testing and commissioning of Butterfly valve (manual) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified: 80 mm dia.

1

-

-

... More
Supplying and placing of bed side Locker with overall dimensions (L)490 mm X ( W)410 mm X (H) 941mm. Locker should have one cabinet with lock and one drawer unit with plastic molded handle. There should be a space between the drawer unit and cabinet, to keep the general items for frequent use. Cabinet should be provided with lock to keep the valuable items for safety. Drawer unit is without a lock to keep the general items. Castors are provided for easy handling. Corner Tube should be made of MS ERW round tube Ø 25.4mm and 1.2 mm thickness Drawer should be made of CRCA sheet Sliders: Telescopic ball slides are used for easy and smooth operation of the drawer. Cabinet: Cabinet should be provided with a lock. Tops made of ABS should have recessed and contoured shape for better asthetics and usability. Knob: Matt finish plastic knob with generous radii - and dome shape for better grip. Castors: Ø50mm Plastic molded castor for better leveling and strength. Powder coating should be Bacteriostatic and thermosetting epoxy polyester,formulated to fulfill the requirements for bacterial protection. All powder coated parts in RAL white. Plastic parts in Grey 5 kg UDL each on Top, on First Drawer and on Mid Shelf. 10 kg UDL in Cabinet.

42

-

-

... More
Providing, laying and jointing in true line and level 75mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to IS 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.

375

-

-

... More
Supplying, laying , testing and commissioning of 2 Core X 1.5 Sqmm Shielded Flexible Copper Cable (per Soft I/O points to DDC). as per technical specification etc. as required.

2500

-

-

... More
Mineral wool insulation Providing material and labour for installing 50mm thick 48kg/cum density mineral wool (pre-wrapped) in the wall panelling and over acoustic false ceiling as per required application, for all floor, all height, all level as per drawing and as directed by engineer in charge.

50

-

-

... More
Fiber cement board : Providing material and labour for fixing exterior grade cement fibre board/ plank cement pattas of 8 mm thickness at exposed concrete ceiling/ wall/ beam bottom with brass/ SS head screws as per drawings, specification and sample approved at all floors, all levels and all shapes etc complete as directed by engineer in charge. Rate shall be inclusive of all material, labour, scafolding, tools, tackes etc complete.

3312

-

-

... More
Supply, Installation,Testing and Commissioning of Digital Telephone with DSS console and related software/ licences as per tender specification etc. as required.

1

-

-

... More
Providing material and labour for fixing 8mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.

38

-

-

... More
Supply, Installation, Testing and Commissioning of 6W Wall mount with max SPL1M/1W 96dB . Frequency response of 160Hz-20KHz. The speaker shoud have tappings at 6W/3W as per technical specification etc. as required.

4

-

-

... More
Rigid PVC drain piping of 10 Kg / Sq. Cm. of pressure rating for the units with insulation as per specifications and suitable for following pipe sizes. 19 mm Dia.

200

-

-

... More
SITC of Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 230 V. 50 C/s. 1400 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2,3 core flexible Copper wire with earthing

10

-

-

... More
Providing material and labour for fixing SS 316 grade push-pull pair of handle of size 1200 mm long (out to out) x 38 mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified.

5

-

-

... More
Providing material and labour for laying precast fair finish curbing of (factory made) RCC M25 grade curbing of required size with all accessories including necessary excavation, cutting the road, laying PCC 1:4:8 (1 cement: 4 sand: 8 stone aggregate 20/37 mm. down size), exposed rendering, curing, flush pointing CM 1:3 as per the drawing, as per approved sample and as directed by Engineer in charge.

50

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-C POWER PANEL As per Single line diagram

1

-

-

... More
Supply, installation, testing and commissioning of Butterfly valve (manual) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified: 100 mm dia.

5

-

-

... More
Providing material and labour for laying shot blasted Non-interlocking (factory made) high density 80 mm thick M45 grade any colour brick type paver blocks of size 200mm x 200mm/ 200mm x 100mm of approved make and shade for footpath, parking areas, service lanes and other areas as mentioned in the drawing including average 50 to 80 mm thick bedding layer of coarse sand below paver block. Laid paver block shall be mechanically compacted and as directed by Engineer in charge. The work shall be executed in line and level by skilled mason of flooring work only for paver blocks. It should be laid in such a way that the No cutting of the paver block to be necessary and if required, cutting of paver block by machine cut only. The Finished surface of the paver block shall have coarse sand texture finish. Sample to be approved before starting of the work by Architect/ EIC.

50

-

-

... More
ELW 12.00 Cable Tray Supply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 300 x 100 made out of 2 mm thick ladder type

890

-

-

... More
Providing material and labour for fixing Mortise shaft dead bolt of approved make with key (Alen Key lock), sleeve with 57mm backset and 25mm square forend in stainless steel satin finish etc complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

5

-

-

... More
Providing material and labour for fixing in expansion joint 100 mm thick SIL FLEX (Capcell HD 100) expansion joint board of best quality and approved make including cutting to required size and shape for all floors, all height etc complete as directed by Engineer In charge.

628

-

-

... More
Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) P.C.C. work

20

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. AUTO BALANCING VALVE complete with Flanges Nutbolts and Working parts 65mm dia.

67

-

-

... More
Providing material and labour for fixing of expansion joint system for 100mm wide expansion joint gap of 3R/ Kantaflex/ Sanfield or equivalent related with floor location. The joints system will be of extruded aluminium base members, self aligning/ self centring arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor expansion control system with stone fixing arrangement for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it’s components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centring arrangement that freely rotates / moves in all directions. The Self – centring arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. Expansion joint shall be tested for their watertight property & the same shall be watertight for a period of five years. Material shall confirm to ASTM 6063. Rate shall be for model with stone (flush with adjoining flooring) fixing arrangement. Stone shall be fixed in expansion joint system (in recess part) with suitable adhesive as per manufacturer' specification. Rate should be inclusive of necessary scaffolding work, non shrink grout, RCC cutting, edge preparation etc complete. Cost of stone shall be paid in relavant tender item.

36

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. AUTO BALANCING VALVE complete with Flanges Nutbolts and Working parts 50mm dia.

2

-

-

... More
Providing and fixing unplasticised -PVC corner gully trap of size 200mm long x 200mm wide , having 80x80x115 mm vertical connection for 75mm diameter pipe, of approved design as per IS: 14735, to unplasticised - PVC SWR (Type A) pipes at all floors and all levels as indicated in the drawings, within the floor bedding, including cutting floors and walls as required, and making good the floors and walls etc. complete as per the direction of the Engineer-in-charge.

18

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 4500 CFM / 40mm Static Pressure for O.T

4

-

-

... More
Providing and fixing U.P.V.C (Type B) conforming to IS 13592, & fittings conforming to IS 14735 of approved make Multi Floor Trap Height Riser with 50mm x 50mm x 75mm inlet x 110mm dia outlet, as per specifications & at all levels & at all heights, as approved and directed by Enigeer-in-charge.

130

-

-

... More
Providing material and labour for fixing SS 304 grade brush finish solid Door bufer with pvc base, wall mounted (square/ round) of approved make with necessary screws etc. complete as approved by Engineer-in-charge in Charge.

74

-

-

... More
Supply, Installation, Testing and Commissioning of Fire Hose Cabinet of size 750mmx600mx250mm fabricated from 18 swg thick MS sheet with 6mm thick glazed hinged type centre opening doors having locking arrangement suitable for accommodating 2 nos RRL hose pipes, 1 no. nozzle, branch pipe & painting with two coats of anti-corrosive primer and two coats of approved red enamel paint etc. complete as required.

24

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for AHU's (30 Nos) VFD Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.

1

-

-

... More
ACP sheet signage : Providing, Making and fixing 3 mm thick ACP sign of any shape and size and of approved make to be cut on CNC router cutting and smoothen all corners and edges. Matter shall be cut in 3M High intensity prismatic Reflective vinyl ASTM Type 4 and paste on it as per design and detail and as per manufacturer's specifications. UV stabilized lamination shall be done on it. The ACP sheet shall be fixed with clamp and angle on new or existing MS Pole as per drawing. Content of sign shall be letters (In Gujarati & English), graphics / maps, signs etc. in any colour as per design, drawing and approved by Architect and Engineer. All side of box shall be covered with fresh ACP sheet, but only one side elevation area shall be measured and paid in sqmt. Cost of MS Pole and Civil works shall be paid as per relevant tender items. The rate shall also include cost of scaffolding, drilling, fabrication, finishing, adhesive material, etc at all height and all lead, angle, fixing charges, etc. The contractor should submit the drawings based on concept design and do the sampling and get it approved before execution.

5

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Energy Meter's ( 40 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.

1

-

-

... More
Providing material and labour for laying 60mm thick Solid Concrete Combination Cobbles of differant size, made by vibro pressed method of VYARA or equivalent as approved by Architect/ EIC, with +/-3mm tolerance and thickness of wearing layer not less than 5mm of any color and shade (UV Light resistant fast colours from Lanxess only to be used) having compressive strength of 30 Kg/cm2 for footpath, parking areas, service lanes and other areas as mentioned in the drawing. Combination cobbles shall be laid as per approved pattern and suggested by manufacturer and Architect. Including providing and laying average 50 mm thick average bedding layer of coarse sand below the block as per required grading and specification.Laid paver block shall be mechanically compacted and as directed by Engineer in charge. The work shall be executed in line and level by skilled mason of flooring work only for paver blocks. The Finished surface of the paver block shall have coarse sand texture finish. Sample to be approved before starting of the work by Architect/ EIC.

50

-

-

... More
Providing material and labour for, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tripper to site, laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.

100

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 11950 CFM / 23.60 TR For Trauma ICU at Ground Floor

1

-

-

... More
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter 12W LED -Make Crompton or equilavent (LCDSPLN-R-12-CDL)

421

-

-

... More
Perforated Gypsum tile acoustic false ceiling : Supplying material labour for fixing of Suspended ceiling system with 12.5mm thick glass fibre perforated gypsum plaster board/ tile of any size having any type of edges and any shape, any size, any pattern perforation and GI suspended framing system. This includes ribbed frame Perimeter Channel fixed to brick wall/partition with the help of nylon sleeves and screws at 600mm centres along the perimeter of ceiling. Then suspending ribbed section used as intermediate channel from the soffit at 1220mm centres with Ceiling Angle fixed to RCC Slab with Soffit Cleat and steel expansion Fasteners @ 600mm Centres respectively. Ultra frame ribbed Ceiling Section are then fixed to Intermediate channel with the help of four point connecting clip (0.8mm thick) and in perpendicular direction to the intermediate channel at 600mm centres. All framing and grid section shall be GI (as per IS 513) having yeild strength 300 mpa and galvanized finish of 150 GSM as per IS 277. 12.5mm thick glass fibre perforated gypsum plasterboards/ tile of any size having any shape, any size, perforation of any pattern is screw fixed with 25mm long Drywall screws at 230 mm centres. 50mm thk 24kg/m3 glasswool should be placed between the frame and perforated board with the help of Glasswool tissue bag. The screw fixing of gypsum plasterboards to the metal framing at the periphery, openings and cut edges should be at 150mm centres. Finally square or tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound, Joint Paper tape and two coats of Drywall Top Coat as per the drawing & approved sample. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, scafolding, making grooves between wall & board or as per drawing etc complete for all level, all height, all floor amd as directed by Engineer in charge. Only plan area shall be considered for payment.

987

-

-

... More
Supply, Installation, Testing, Commissioning of Temperature with Humidity Sensor, IP65 rated with RH accuracy 3 %, temp accuracy +_ 0.7 deg (0 to 70 Degree)

39

-

-

... More
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 95 Sq.mm x 3.5C Al. Cable

247

-

-

... More
Providing material and labour for fixing Fire rated (120 minutes) Rack and pinion non-handed door closer of approved make EN size 2-4, with back check and standard arm with two independent closing valves and latching speed adjustable by arm. All adjustment screws face fixed with slide plate. The door closer shall be with Silver finish cover. The door closer shall conform to EN 1154 standards and CE marked with necessary fittings etc. complete for all floor, all height as recommended by manufacturer and as directed by Engineer in Charge.

9

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 800 CFM

4

-

-

... More
Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.00 mm sheet

20

-

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm PVC couting on outer side including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

50

-

-

... More
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter 18W LED -Make Crompton or equilavent (LCDSPLN-R-18-CDL)

1025

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 8.48 TR / 4250 CFM For Passage at First Floor

1

-

-

... More
SITC computer power supply point with 2 nos of 6 amp 5 pin socket with 1 no. of 6/16 Amp. socket with 1 no 16 A Switch with indicator & wiring of computer point will be done through 2 nos.of 2.5 sq. mm Cu. wires as phase & Neutral and 1 nos. of 1.5 sq.mm.as earth wire. .( This cost includes the wiring from DB to Computer point.)

239

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: 17.7.9 White Vitreous China Surgeon Type Wash Basin size 660x460 mm with a single 15mm C.P. brass pillar tap with elbow operated lever (ISI marked)

49

-

-

... More
Supplying and erecting, testing and commissioning of 46W 8' Feet LED Surface Mounted indoor Channel Linear Lights Fittings with diffuser-Make SP780P LED 52S-6500PSU W6L240ODSIor equivalent as per apporved make list.

53

-

-

... More
Supplying, Installation, Testing and Commissioning of Control Panel suitable for automatic operation of fire fighting pumps consisting (1no. of Electric, 1 no. of Pressurize pump & 1 no.of standby Diesel engine pump.) (a) Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price. (b) Facility for more selections i.e auto or manual. (c) Protection failure and control cabling. (d) interlocking of pressure switch with pumps (e) Compatible for IBMS Major component of panel are as under : Incomer - TPN MCCB with Bus coupler RYB indication lamp. - 1set Digital AMtr and voltmerer - 1set Window announciator with hooter, TPN AL busbar Outgoing : TP MCCB with soft starter and push buttons and with all required accessories . Complete in all respect.

1

-

-

... More
Supply, installation, testing and commissioning of C.I. Gate valve (PN 1.6) as per IS:14846 complete as required: 80 mm dia.

1

-

-

... More
Providing material and labour for fixing powder coated multi point lock with mortise handle (without lock) of approved make of required capacity with heavy gear mechanism including all required accessories like nib, nib holder, counter plate, fork, pawl, polyamide strip, dummy handle etc as per approved manufacturer recomendatation for aluminium sliding doors and window with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

50

-

-

... More
Providing and applying 400 microns thick coal tar extended epoxy resin coating to sound concrete surface after carry out surface preparation to remove loose concrete, curing compound or any other foreign material, mixing base and hardener component of Coal tar extended epoxy resin coating, apply first coat at 200 microns DFT using suitable brush or roller, allow the first coat to dry for 6 hrs at 35°C followed by application of application of second coat at 200 microns DFT in perpendicular direction to first coat etc. complete as per manufacturer’s specification for all level all depth as directed by engineer incharge. Coal tar extended epoxy resin coating shall be having 100% solid contents by weight, specific gravity - 1.54 at 27°C, Curing efficiency – 93 % (BS 7542), Water absorption 0.01 % (ASTM D 570), Bond Strength: min 1 N/mm2 (BS 1881 Pt 207), Water Permeability: nil at @ 2 bars pressure over 3 months, Salt spray test: nil @ 200 microns DFT over 1000 hrs (BS 1881 Pt. 124:1988), Impact Resistance: passed (BS 3900 Pt E3) & Chemical resistance checked in accordance with ASTM D 453

100

-

-

... More
Providing material and labour for roughened strip 2.5 cm wide to form antiskid surface on treads of stairs in any type of stone including forming straight deep curved gishi (groove), 6 mm wide & 4 mm deep on two sides of the roughened area, chiseling, polishing the edges, sides and bottom of gishi etc. complete as per sample approved for all floor, all height. Only one time length of tread of stair shall be measured for payment.

509

-

-

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. as per technical specification etc. as required.

29

-

-

... More
Providing and fixing of 10 mm thick Multicell UV protected Polycarbonate Panel System with 3 cells and 4 walls structure over structural steel / MS purlins per approved colour/shade for plain or curved (dome type) roofing work. Co-extruded UV protected panels shall have width of 900mm to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Welding or gluing up of standing seam is not acceptable. Panels shall be fixed on purlins with Stainless steel retention clips and connectors. Snap-on connectors to interlock the panels shall have a grip-lock single tooth locking mechanism to ensure maximum uplift capability. Panels shall have End-cap/ Aluminium U-profile/ Glazing bar for ends as per requirement. The weight of the system shall not be less than 2.30 kg per square meter. Panel shall be co-extruded with specialist-glare compound to make it anti-glare/soft light to prevent glare and sun streaks. Panels shall be fixed over structural steel/ MS purlins conforming to the detail technical specifications and as per approved architectural drawings. The rate shall include the cost of above specified materials, fixing of the sheet, scaffolding and labour charges for working at all levels, leads and heights as directed by engineer in charge. Surface area of roof sheet shall be measured for payment. The supporting MS structure for panel shall be paid separately in relevant tender item.

50

-

-

... More
ELW 08.00 Distribution Board DISTRIBUTION BOARD Supplying, assembling, grouting, levelling, installation, Connecting testing and commissioning of D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement. Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 8 SPMCB as outgoing per phase (i.e. 12 way TPN D.B.) with 12 way PPI kit

18

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. and above Bonded Treated Woven Glass Fibre for Outer covering of Insulation Material GC bonded applied by suitable adhesive. Density: 200 +/- 20 gsm Thickness: 0.18 mm / 7 mill, The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 25mm

105

-

-

... More
Providing, laying and jointing in true line and level 40mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to IS 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.

140

-

-

... More
Providing material and labour for fixing SS 316 grade push-pull pair of handle of size 200 mm long x 19mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified.

211

-

-

... More
FRP UG Tank cover Providing and Fixing mediumduty double seal FRP UG Tank cover with frame of 5MT capacity, in matching shade of surrounding pavement and design according to EN - 124:1994 of HP or equivalent of clear opening size of 600mm dia having frame thickness average 50mm and cover thickness 25mm, of weight average 35 Kg with client's logo etc. complete as approved by architect and as directed by engineer in charge. Frame shall be embaded in concrete of M25 grade and top level of frame shall be flush with road level. Rate shall be inclusive of cover frame and concrete work.

20

-

-

... More
Providing material and labour for laying 8 to 10 mm thick machine cut polished Granite stone slabs of same shade as flooring and as per approved sample in skirting upto 100 mm high as per drawing (flush with plaster) laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including providing 10mm wide grove between skirting and plaster, rubbing and finishing complete. Shade of skirting must be match with flooring stone.

1635

-

-

... More
Providing material and labour for fixing fabricated metal single shutter/ double shutter trap door made from 0.8 mm MS sheet, Inner Frame - 1.5 mm, Outer Frame - 2mm MS sheet and finished with powder coating of approved shade/ enamel/ acrylic paint (primer + 3 coats of paint) of approved make and shade. Door shall be installed on existing false ceiling framing with extra MS suspender with necessary hardware like allen key lock, hinges/ pivot, safety chain etc complete as directed by engineer in charge. Rate shall be inclusive for providing, loading/ unloading, transporting and installation at all floor all height but excluding the cost of extra suspender for installing the trap door. Area of trap door with frame shall be measured for payment.

348

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 100mm dia.

12

-

-

... More
Providing and arranging in position set of work surface contains main table with modesty panel, side unit and back unit (storage unit) of Cignus of Godrej or equivalent with knock down construction system. Main table of approximate size 2350mm x 1200mm with two working level and back unit of size 1800mm x 750mm. Total assembly shall be maade of 25mm thick prelaminated partical boardof approved shade with PVC membrane pressed on it, PVC lipping at exposed edges, MS powder coated member. Required hardware shall be provided i.e. wire management system, handle, lock, sliding mechanisam etc.

1

-

-

... More
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Blower status in Air able to measure pressure at zero pascal pressure.as per specifcation

45

-

-

... More
Supplying , fabricating and installation of various sizes clamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc.

5937.5

-

-

... More
Supply, Fabrication, installation and testing of Flexible Duct Connections of standard length 1.5 meter. 100mm Dia.

2

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B LIGHTING+SMALL POWER PANEL As per Single line diagram

1

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm

4580

-

-

... More
Providing and arranging in position Working Table of aprroved make Finesse of Godrej or equivalent of approximate size 1200 Width mm x 600 Depth mm x 740 Height mm with knock down construction system. Table top shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick backing laminate. Flat edge Duly sealed with 2 mm thick PVC beading. The modesty shall be 18 mm thick plain particle board Clad with 1.0 mm thick laminate of approved shade on both sides. Edge Sealed with 2 mm thick PVC beading.

1

-

-

... More
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter -Make Ligman or equilavent (TANGO-TA-80551 37W LED) ( EXTERIOR-IP65)

12

-

-

... More
ELW 18.00 Miscellaneous MISCELLANEOUS PVC PIPES Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 25 mm dia with GI pulling wire.

50

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Exposed to Atmosphere Closed Cell Nitrile Rubber GC bonded and above it 2 layers of UV paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and above it 2 layers of UV paint shall be applied , over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 40 mm dia.(32 mm thick insulation)

50

-

-

... More
GI Open Cell ceiling 100mm x 100mm Providing and fixing in true horizontal level Open cell GI lay-in ceiling tiles with border panels forming flush-tegular edge of size 600x600x38mm having Fire Performance CLASS A1 as per EN-13964. The tile shall be powder coated of approved colour having powder coat thickness ranging from 60-80 microns. The tile with cell size of 100mm x 100mm shall be laid on Suprafine 38 with 15 mm wide T-section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 12.5 Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of same make. Warranty Certificate and Test Reports for Fire rating shall be provided by Vendor. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum. Installation to be carried out by Trained Installation team and as per recommended procedure of approved manufactur. SUSPENSION SYSTEM accessories consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum pull strength of 110 kgs. (Adjustable hook clips of 0.7mm thick, galvanized spring steel can also be used for installation purpose as an additional accessory. The adjustable clip also consists of a 4 mm aquiline wire to be used with the main runner).

2046

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B POWER PANEL As per Single line diagram

1

-

-

... More
Supplying, Installation, testing and commissioning of LC-LC single mode duplex fiber optic patch cord 1mtr. as per technical specification etc. as required.

15

-

-

... More
Providing and fixing C.P. brass Shower arm for over head shower of approved make and quality, and as approved by the Engineer-in-charge, and conforming to Manufacturers Standards. a) Size: Casted 190mm long light body round shape for wall mounted shower rose with flange, of approved make and as per the direction of the Engineer-in-charge.

77

-

-

... More
Supply, Installation, testing & commissioning of Insulation of above Air & Dirt Seperator with Nitrile Rubber with Woven Glass Fibre Covering insulation complete as per technical specifications, drawings and requirements

1

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control / Monitor module complete as required. as per technical specification etc. as required.

51

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

106

-

-

... More
Providing and Fixing in position CP brass Pressmatic Urinal Flush Valve Auto-closing system with built in Control Cock and Wall flange of approved or equivalent make, including 15mm S.S. pipe connection with Urinal, and including all necessary materials required for fixing. All complete as per directions of the Engineer-in-charge.

88

-

-

... More
Providing material and labour for fixing of expansion joint system for 100mm wide gap of approved make related with internal wall and ceiling joint location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner/ ceiling application, with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Rate shall be inclusive of polyester powder coating of approved shade and make. Expansion joint system shall be as approved for all floor all level including scafolding etc complete as dircted by Engineer in charge.

437

-

-

... More
Providing, fixing AUTO GLOW photo luminescent Signage's as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Fire Lift: 4" x 12"

3

-

-

... More
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (e) 50mm dia nominal bore.

18

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 700 CFM

10

-

-

... More
Sec.4.0 Access Control System “Providing & erecting approved make Fingerprint and card based premium Door controller with LCD and Keypad having following features.”(A) Optical Fingerprint and card based Reader (Card personality Module not included) “(B) Dot – Matrix LCD and Touch sense Keypad “(C) Built-in interfaces like door lock, door sense exit Reader, Exit switch, Ethernet RS485, Aux Input & aux output port “(D) 5000 Events, access Control, Time Attendance, Tamper Detection “(E) 4 LEDS and Buzzer”

1

-

-

... More
Providing and arranging in position 32 seater Conference Table with Wire Manage of Senate of Godrej or equivalent of approximate size 760 Width mm x 600 Depth mmx length as per sitting with half round table. Conference Table shall be made out of CRCA steel having epoxy poyester powder coating of 50 microns for under structure, approximate 30mm thick membrane finish top, pre laminated board for modesty panel and MDF board for wire management system. Conference Table shall be of knock down construction with proper edge profiling and wire management system. Cost of chairs shall be paid in relevant tender item.

1

-

-

... More
SITC of Blank Plates

420

-

-

... More
Providing material and labour for fixing 10mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.

38

-

-

... More
Supply, Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 80KVA UPS 3 ph in 3 ph out for balance load

2

-

-

... More
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.

290

-

-

... More
Providing material and labour for fixing Aluminium powder coated butt hinges of required capacity of approved make for casement window/ door (europrofile) with necessary accessories, screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

552

-

-

... More
Providing and fixing of 15mm nominal bore CP Brass Angle valve confirming to IS: 8931, for wash basins, water coolers, geyser points, etc of approved quality and as approved by and directed by the Engineer-in-charge.

625

-

-

... More
Dismantling santtary fittings like wash basin . W.C. pan Indian and European type, flushing tank etc. including stacking the materials with all lead and lift.

20

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 18.2.1 - 1216 (16mm OD) pipe

200

-

-

... More
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 4 Sq.mm x 4c CU. Cable

585

-

-

... More
Providing and arranging in position set of work surface contains main table with modesty panel and back unit (storage unit) of Trident Senior of Godrej or equivalent with knock down construction system. Main table of approximate size 1800mm x 450mm x 750mm and back unit of size 1800mm x 450mm x 750mm. Total assembly shall be maade of 25mm thick MDF board with PVC membrane pressed on it/ one side laminated board, PVC lipping at exposed edges, MS powder coated member. Required hardware shall be provided i.e. wire management system, handle, lock, sliding mechanisam etc.

5

-

-

... More
Pylon signage - 450X1200 Providing and fixing of Totems of size 450mm x 1200mm using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. Internal structure to be made from ms section of required size with proper support in between and 3mm ACP to be slided from both sides. 3mm ACP to have 3M vinyl printed with Hp latex 3rd Gen Eco friendly non toxic inks with UV lamination and 2 year print warranty 3 mm ACP sheet with High intensity Prismatic Grade reflecitve sheeting with top hat of 2 mm Aluminium and bottom hat of MS 6 mm thick depending on size of Pylon.

3

-

-

... More
Providing and fixing Urinal or approved quality including conecting the Urinal with waste pipe , tap etc. complete.(A) White earthenware flat back or corner type size 430mm x 260mm x 350mm.

57

-

-

... More
Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors with VFD & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly.Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accesories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. 13500 CFM / 20mm Static Pressure for Plant Room

1

-

-

... More
Providing material and labour for fixing machine cut average 18mm thick mirror polished Granite stone slab of approved shade as per approved sample for dado, cladding, skirting etc., in required design and pattern as per drawing, laid on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, or fixed with stone fixing adhesive as per manufacturer's specifications including mirror polishing, pencil sharped edges, edge polishing, rubbing, curing, finishing, necessary scaffolding, maintaining upto handling over the project etc complete for all floors any heights, any lead and lift etc complete as directed by Engineer Incharge. Baking coat plaster for dado shall be paid in relevant tender item. Shade of skirting must be match with flooring stone.

146

-

-

... More
Supply installation testing and commissioning of 55" Full HD LED Video wall display, 3.5 mm bezel to bezel, 500 Cd/m2 brightness, DVI-D Loop out-Daisy chain, DVI- D IN X 1, VGA X 1, HDMI X 2, DVI-I Out x 1, LAN, with required mounting bracket as per site requirement. as per technical specification etc. as required.

4

-

-

... More
Providing and fixing of Non Fire rated Hollow metal door of approved make and shade at all levels from ISO 9001-2000 certified Manufacturer. All hollow metal general doors with or without vision panel. Pressed Galvanized steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be Double rebate profile of size 143 x 57 mm made out of 1.20mm thick galvanized steel sheet (18 gauge). Frames should be Mitered and field assembled with self tabs. Frames should be fixed with back plate bracket and anchor fasteners of approved size and make for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement slurry if recommended on the clear masonary opening. Door leaf should be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (22 gauge) minimum thick galvanized steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be as per joinery details with a screw on glass beading on the inside. The glass should be 5mm clear toughened glass. Shutter shall be fixed to frame with SS 304 Ball Bearing Butt Hinges of size 100mm x 75mm x 3 mm (no of hinge as suggested by engineer in charge). All door shutter and frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate shall be include supply and installation of door i.e frame, anchor fastener, shutter with vision lite, hinge but exclude the cost of hardware (other than hinge) etc complete as directed by engineer in charge. Out to out area of door with frame shall be measured for payment.

10

-

-

... More
25 mm Dia.

450

-

-

... More
Providing and fixing ABS Chrome plated Brass Hand Shower (Health Faucet) of approved make and quality and as approved by Engineer - In - Charge, including 8 mm dia, 1 Meter long Flexible tube & wall hook including cutting and making good the walls wherever required complete as per directions of the Engineer-in-charge.

20

-

-

... More
Supply, Installation, Testing and Commissioning of 150 mm dia Pressure Gauge of range 0 - 15 Kg / cm² conforming to IS - 3624 having bourdon tube of stainless steel 316 in cast aluminium, stove enameled, black, weather proof case with outer, screwed aluminium bezel and complete with necessary U-type stainless steel siphon tube and cock including providing suitably painted angle iron support to the tube etc.as per specification complete as required.

4

-

-

... More
Providing material and labour for laying average 25mm thick machine cut polished Green Kota stone slab of size upto 900mm in flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift in any shape and pattern etc complete as directed by Engineer In charge. Sample shall be approved before execution. Kota stone shall be in uniform shade of reuired size. Sample and mockup shall be approved procurement of material.

1656

-

-

... More
Providing material and labour for Disposing off the un-used excavated earth (black cotton soil), debris, malba, dismantled materials for all lead and lift/ depth out side the campus at non objectional place as directed by Engineer in charge.

50

-

-

... More
Vaccum dewatering Extra for carrying out vaccum dewatering & Power floater treatment in roads, pavements, floors well compacted, mechanically vibrated with screed vibrator, finished to required levels, floated with neat cement and power trowelled to get desired smooth finish / broom finish, over a leveling course, including MS channel or box shuttering, curing for 10 days with gunny bags etc complete. The size of panel should be approximately 3.75 x 5.5 m or as directed by Engineer. The Contraction joints to be formed at every 5m distance by grooving with mechanical saw within 48 hrs. Groove/sawed joints/ longitudinal joints shall be made of 6mm width and 25 mm depth min (1/3 rd depth of the pavement) as shown in the drawing. The rate shall be inclusive of labour, making the grooves and machinery cost.

50

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 18.2.4 - 2532 (32mm OD) pipe

90

-

-

... More
Supply, installation, balancing and commissioning of Factory fabricated Aluminium ducts as per “SMACNA” Standards specifications for MRI Room - Supply, Fabrication, installation and testing of Ractangular sheet metal ducts in accordance with the approved shop drawings and as required by the specifications. Thickness 0.80 mm sheet

20

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 25mm dia.

7

-

-

... More
Providing and arranging in position leatherette finish visitor chair of Marvel of Godrej or equivalent with approved shade of fabric. The seat and back shall be made up of Injection molded Plastic outer & inner and PU foam and MS ERW tube and upholstered with Leatherette. The one-piece armrests should be injection moulded from black co-polymer polypropylen. Chair have cantilever type SS tubular frame as legs.

6

-

-

... More
Providing material and labour for applying hydrophilic crystalline based waterproofing for concrete walls, raft (basement and under ground water tank) with system In two coat application. The application to be done from + ve (positive) side on a wet open pore green concrete surface at coverage of 0.8 to 1 Kg/Smt as per manufacturer specification. It should be hydrophilic in nature, should be able to grow crystals year after year to seal microcracks.The product should confirm to DIN 1048 part 5 and should provide in depth crystallization. The product technology should be CPWD and EIL approved. Application should be done on wet surface after 3-6 hours of casting of concrete. The material and application warranty to be given by manufacturer’s authorized distributor/ applicator on prescribed format. Rate shall be inclusive of construction joint treatment, crack repair, patch repair, grouting, including cost of scafolding for all height all level as directed by engineer in charge.

2394

-

-

... More
Providing, laying and jointing in true line and level 160 mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.

200

-

-

... More
M.S. Above Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / gaskets / Nut bolts etc., and laying on the surface including painting with one coat of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required: 80 mm dia

530

-

-

... More
Providing material and labour for applying external finish of average 2 to 2.5mm thick acrylic polymer based texture and pattern with standard tool and applicator as specified by manufacturer on exterior surfaces at all heights including scaffolding to give even shades including thoroughly brushing the surfaces free from mortar droping and other foreign matter and sand paper smoothed as per the manufacture specifications etc. complete for all floor, all height, all level and up to the satisfaction of Engineer in-charge/ Architect. The rate includes making of grooves, pattas and finishing as directed by Engineer in charge. Paint shall be measured and paid in seperate tender item. (Item should be executed by approved applicator only.)

12990

-

-

... More
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required. 17.10.2 - Kitchen Sink without drain board: Size: 610 x 510 mm bowl depth 200 mm.

36

-

-

... More
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 70 Sq.mm x 3.5C Al. Cable

215

-

-

... More
Cooling Towers Supplying, installing, testing and commissioning of FRP induced draft counter flow rectangular multicell type CTI approved FRP cooling tower of 170 TR heat rejection capacity single cell and multi fan with PVC fillings with intergal louvers and drift eliminators open pan sutaible flow water distribution complete with hot FRP water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced two nos. axial flow type fan-direct driven with PVC blades & Al Alloy Hub driven IP55 TEFC 710 RPM vertical flange mount motor suitable for 415 ± 10 % V, 50 Hz, 3 phase supply; power / control wiring, earthing, drain, make up, quick fill connection and vibration isolation etc. as recommended by mfr. not less than tender specified requirements; Tower Design Capacity shall be 170 TR (equivalent THR) when designed for Temp Range = 4 °C, Cooling water Flow 680 GPM and Leaving temp 32 °C at 28.0 °C design WBT; L/G ratio and Evaporative loss calculations shall be submitted along with the bid; Water Temp In - 36.0 °C, Water Temp Out - 32.0 °C, For Chiller Capacity - 170 TR, Flow Rate - 680 GPM (2 working + 1 stand by). For Chiller TR / Flow Capacity - 170 TR / 680 GPM

3

-

-

... More
Sec.9.0 Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. 1st Year after DLP

1

-

-

... More
Providing and arranging in position plain Storwel of Godrej or equivalent of approximate size 900mm(W) x 475mm(D) x 2000mm(H) with welded construction. storwel shall be made of CRCA ‘D’ grade high yield strength as per IS:513 in shelf (0.7mm thick), Back (0.8mm thick), Door (0.8mm thick) and all other components (0.9mm thick). The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (+/- 10). Storwel shall be approved shade.

50

-

-

... More
MCCB SITC of 100 A FP MCCB with Sheet steel metal enclouser

2

-

-

... More
Tag Blocks - Multipair Telephone Cable Termination Supply & fixing of 100 pair MDF unit with required modules in a fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock, provision for earthing.

4

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 850 CFM

2

-

-

... More
Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), P - Trap as approved and directed by the Engineer-in-charge. For 110 mm Dia pipe

388

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts. 25mm dia.

50

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 2600 CFM / 40mm Static Pressure for Toilet

2

-

-

... More
Sec.9.0 Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. 5th Year after DLP

1

-

-

... More
NICU Bed wirh Baby Warmer Providing, arranging in position and conection with services of NICU Bed with Baby warmer with Micro Computer Temperature Controller including dual monitering system, feather control panel, safety alarm etc, Heater Box, Baby Bassinet, Displys and auto mode system.

30

-

-

... More
SITC of 63 A FP MCB

10

-

-

... More
Supply installation testing and commissioning of AV over IP JPEG 2K Encoder with 1 X HDMI IN, 1 X LAN, 1 X RS232 Out, featured with videowall function with mounting accessories. as per technical specification etc. as required.

4

-

-

... More
Providing material and labour for fixing FRC (Fiber reinforcemed concrete) Heavy Duty Man Hole Cover with frame of intrnal dia 560mm with 100x2mm MS flat allround, 16mm ø plain round bar for lifting the cover & should be fitted with plastic cups etc complete as directed by engineer in charge. On the upper periphery of frame 25 x 3 mm wide MS flat with hot dip galvanizing should be well embed in concrete to protect the edges of frame.

50

-

-

... More
Supply, Installation, Testing and Commissioning of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection as per technical specification etc. as required.

3

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 50mm dia.

9

-

-

... More
Providing and arranging in position set of work surface contains main table with modesty panel, side unit and back unit (storage unit) of Maestro of Godrej or equivalent with knock down construction system. Main table of approximate size 1800mm x 900mm x 750, side unit 1200mm x 600mm x 730mm and back unit of size 1400mm x 450mm x 750mm. Total assembly shall be made of 25mm & 18mm thick melamine faced board, 30mm MDF board, PVC lipping at exposed edges, MS powder coated member. Required hardware shall be provided i.e. wire management system, handle, lock, sliding mechanisam etc.

1

-

-

... More
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 128 MB RAM & 64 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for HRU & CSU - as per IO Summary and as per technical specification etc. as required.

1

-

-

... More
Sec.6.0 ELV WORKS MV switch gear & Power panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-A POWER PANEL As per Single line diagram

1

-

-

... More
Supply, Installation, Testing and Commissioning of industry-standard intel based server, The minimum specifications required are as follows : - Processor : Quad Core Intel Xeon, Dual Core, i7 or above - Memory : Minimum 16 GB - Hard Disk : SATA SSD with 4 TB - Oerating System : Linux SUSE - Vendors to provide Duplicate Servers in HOT STANDBY MODE as per tender specification.

2

-

-

... More
Supply, Installation, Testing and Commissioning of 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W as per technical specification etc. as required.

169

-

-

... More
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50 mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610 mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.

1400

-

-

... More
Providing material and labour for fixing in position PVC pipe sleeves of 75mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location).

50

-

-

... More
Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm outside layer and 0.8mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan with 50 mm static, 4 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), with Mixing box, filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, belt with TEFC drive motor (Eff-1) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, supplied with factory fitted matching size 2 way ON / OFF actuator type Brass / Control valve / Cu piping with required couplings and ends flanged to fit CHW In / Out piping, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan and duly internally wired and tested. Followings are capacities. (With 5 Micron Filteration) 1.93 TR / 900 CFM For Labour Room at Ground Floor

1

-

-

... More
Supply, Installation, Testing and Commissioning of Air vessel,size of 250 mm dia., 8 mm thick M.S sheet, 1200 mm in height with Air release valve on top and flanged connection to down comer, drain arrangement with 25 mm dia. valve, pressure gauge with required accessories and painting with synthetic enamel paint of approved shade as required. The vessel shall be suitable for working pressure 8 kg/cm², Hydro test at 12Kg/cm².

1

-

-

... More
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Filter status in Air able to measure pressure at zero pascal pressure.as per specifcation

45

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-A UPS POWER PANEL As per Single line diagram

1

-

-

... More
3.5C X 150 SQ. MM. AL XLPE CABLE

12

-

-

... More
Providing material and labour for Filling in foundation, plinth and plot filling with murrum (brought from out side) in layers of 20cm. thickness including watering, ramming and consolidating etc complete as directed by Engineer in charge.

3066

-

-

... More
WATER COOLERS: Providing and erecting water cooler having storage capacity 80Ltr. & cooling capacity 40 Ltr.per hour @ an ambient temp of 450 C. The outlet temp. of the water should drop by 150 C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating coil, thermostats, relay etc. complete with necessary inlet & outlet connection. The body of water cooler will be made from Stainless Steel.

47

-

-

... More
Supplying and erecting, testing and commissioning of 36W LED Recessed Mounted Square indoor Panel -Make Crompton or equilavent (LCTLRN-36-F0-CDL)

40

-

-

... More
Supply, Installation, Testing and Commissioning of Hardware based Wireless Access Controller, License with Minimum 50 Access point and support up to 128 access point, as per tender specification etc. as required.

1

-

-

... More
Supply & fixing of 500 pair MDF unit with required modules in a fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock, provision for earthing.

2

-

-

... More
SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 95 Sq.mm x 3.5C Al. Cable

10

-

-

... More
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 32 mm dia with GI pulling wire.

50

-

-

... More
Supply, Installation, Testing and Commissioning of User Call Control Application for all users/extensions, Voice Messaging Application inclusive of voice mail licences for users and inclusive of computer application and operating system, Emergency response services with voice messaging, inclusive of licences as per technical Specification.

1

-

-

... More
Providing material and labour for applying required coats (min two coats) of white cement based putty after thoughly brushing the surfaces free from mortar dropping and other foreign matter. Preparing the surface even and sand papered smooth, after applying every coat of putty complete. Priming coat of alkali resistant cement primer (water or solvent based) is to be applied over prepared smooth surface (undulation free) etc. complete as directed by engineer-in-charge. After application of putty work, wall surface shall be in levelled and without undulation. The rate shall include the cost of filler for filling the cracks on surface, thoroughly brushing the surfaces with sand paper to make it free from mortar dropping and other foreign matter, scaffolding etc. as directed by engineer in charge.

76153

-

-

... More
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / Hot Water multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built 2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with "Y" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 800 CFM

9

-

-

... More
Sec.3.0 Chilled Water Piping INSULATED CHILLED WATER PIPING Insulation (Exposed to Atmosphere Closed Cell Nitrile Rubber GC bonded and above it 2 layers of UV paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and above it 2 layers of UV paint shall be applied, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 80 mm dia.(32 mm thick insulation)

55

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet

130

-

-

... More
Rebaring : Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 10mm and depth 150mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.

50

-

-

... More
05.00 FIRE FIGHTING WORK Supply, Installation, Testing and Commissioning of Electric driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, centrifugal, end suction pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 80 m. head conforming to IS standards. b) Squirrel cage induction motor with suitable HP with synchronous speed 3000 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. c) Common Base plat for Pump and motor and coupling, coupling guard, vibration pad, cables and other accessories as required for complete Installation of pump set.

1

-

-

... More
ELW 11.00 Cable Termination SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 240 Sq.mm x 3.5C Al. Cable

14

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-A TERRACE HRU PANEL - OUTDOOR TYPE As per Single line diagram

1

-

-

... More
One ceiling fan outlet point controlled by one 6 A switch and hum free electronic type step regulator and cast iron fan box.

367

-

-

... More
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 128 MB RAM & 64 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Plumbing System - as per IO Summary and as per technical specification etc. as required.

1

-

-

... More
Providing and fixing full thread G.I. Tank Nipple (medium duty) as per IS: 1239, including drilling holes in the tanks at required levels, inserting the coupling in place, sealing the hole with silicon sealant, attaching the hex nuts on either side of the coupling as directed and approved by the Engineer-in-charge. (A) 50mm diameter

20

-

-

... More
Providing material and labour for laying Precast designer (Galicha pattern) terrazo tiles of average 30mm thick having strength not less than 4N/mm2, Thickness of wearing layer not less than 6mm with graded stone/ marble chips of size upto 12 mm, laid on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete for all floor all height all level etc complete as directed by engineer in charge. Sample shall be approved before starting the work . Mock-up shall be carried out as per approved sample.

1269

-

-

... More
Supplying, installation, testing and commissioning of 19" rack mounting type fiber shelf for assembly/termination of minimum 24 cores of singlemode ofc cable for LC style components, for optical splicing and provision for storage of pigtails and splices, equipped with adaptors, adaptor plates and any other such all necessary hardware for proper dressing and management of fiber optic cable etc. as required. Any blank adaptor positions must be suitably masked for restricting dust entry etc. as per technical specification etc. as required.

5

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / Hot Water multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built 2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with "Y" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 500 CFM

14

-

-

... More
Supplying, installation, testing and commissioning of USB -Dongle for License Storage as per technical specification etc. as required.

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-A GROUND FLOOR HVAC PANEL As per Single line diagram

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 125 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter sections with MERV 12 filter, MERV 16 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 6R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 4500 CFM / 9.71 TR With 6.0 kW Strip Heaters & Humidistate For O.T - 1 Second Floor

1

-

-

... More
Providing and arranging in position MAYOS TROLLEY of Godrej or equivalent. overall sizes of Base rectangle 504mm X 655mm X Adjustable from 810mm to 1335mm. Height adjustment will be achieved with screw knob mechanism. Bottom frame should be made of 1.2mm thick SS 304 tube of dimension 38 x 38mm square tube. Top frame should be of 1.2mm thick & 304 SS grade rectangular shape of dimension 30 x 30mm. Fixed tube of 3 mm thickness square in shape of 38 x 38mm telescopic tube should be used of 2 mm thickness rectangular in shape of 30 x 30mm. Locking knob should be used ergonomically designed made of SS screw & nylon knob. Tray supporting frame should be of thickness of 1mm. Castors must be injection molded type of 50mm dia having high endurance, anti-static properties.

17

-

-

... More
Providing material and labour for laying sandwich platform comprising of a) Sandwich of 18 mm thick single side polish Granite of approved size, shade and sample on top and 30 mm thick polished kota in bottom with 25mm thick cement mortar (1:4) in between b) At centre vertical sandwich supports of 30 mm thick two kota stone on sides and 20mm CM (1:4) in between and at both end walls vertical supports of 18 mm thick double side granite. c) 75 mm raised platform at bottom with kota on top and 50mm CM (1:4) at bottom, kota stone skirting as per design and approved sample. The rate includes rounding, champhering and mirror polishing of edges, facias of granite, MS support including necessary bonding adhesive (if required). Rate shall be also inclusive of curing, making holes & cutouts for sink, wash basin, Piller tap/ Bib tap but excluding the cost of MS work, plumbing fixtures ans sink. at all floors all height etc complete as directed by Engineer Incharge. (Only plan area shall be measured & paid for). Rate shall be included all kota & granite mentioned in above.

26

-

-

... More
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 152 to 202mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.

50

-

-

... More
Providing material and labour for laying approved quality average 18mm thick mirror polished Granite stone of approved shade in floor, otta in any pattern etc size upto 600mm including average 20 mm thick cement mortar bedding in 1:6 laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as per satisfaction of Architect and as directed by Engineer in charge at all floors/ all levels/ all heights and all shapes. (Only finished work will be measured.) Sample and mockup shall be approvd procurement of material.

3865

-

-

... More
Supply, Installation, Testing and Commissioning of Pressure Switches for automation of fire pumps. Pressure switches shall be double pole single throw type suitable for single phase supply with diaphragm. Aluminum Enclosure with IP 66 protection, cable connection to pressure switch to control panel & other accessories as required.

3

-

-

... More
Providing, fixing, testing & commissioning UL listed SS corrugated braided Flexible pipe, nominal Inlet by outlet 1"x ½" with required accessories to complete the installation: Size: 1200mm

1405

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20 mA electric signal and providing similar transduced feedback output to control system as required. 125mm dia.

3

-

-

... More
Providing material and labour for Fixing Zinc material satin finish 85 to 100mm long Baby Latch with necessary SS Screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

50

-

-

... More
M.S. Above Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / gaskets / Nut bolts etc., and laying on the surface including painting with one coat of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required: 150 mm dia.

808

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 6050 CFM / 8.86 TR With 3.0 kW Strip Heaters & Humidistate For MRI at Ground Floor

1

-

-

... More
Providing material and labour for fixing G.I. hexagonal chickenmesh of size 20mm x 20mm of 22 gauge at junction of concrete and brick work or between different materials after making "V" grove between two different material surface and filled with rich cement mortar and @ 100mm on each side of surfaces including necessary "U" nails/ screws/ washers with cleats for fixing, overlaps, curing, scaffolding etc complete for all floors/ all levels/ all heights/ all shapes as per direction of Engineer-in-charge.

3611

-

-

... More
Providing material and labour for fixing Zinc material indicator bolt of approved make for toilet door with Thumb Turn inside & Emergency Release & Indicator Outside with necessary screws etc complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

87

-

-

... More
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 128 MB RAM & 64 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Electrical Ststem - as per technical specification etc. as per IO Summary and as per technical specification etc. as required.

1

-

-

... More
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq. mm) for integration within AHU room Damper

2

-

-

... More
3.5C X 35 SQ. MM. AL XLPE CABLE

6

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 750 CFM

17

-

-

... More
Providing material and labour for laying average 50 mm thick IPS, water proof cement concrete flooring in 1:2:4 (1 Cement : 2 Sand : 4 Graded Aggregate 10mm Nominal size) to RCC under ground tanks at all heights in line, level and gradient including mixing water proofing compound in recommended proportions suggested by manufacturer as approved by Engineer-in-charge and leaving the surface rough wired finish to receive any type of flooring / smooth finish etc complete for all floor all height as directed by engineer in charge.

111

-

-

... More
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.

50

-

-

... More
Air & Dirt Separator Supply, Installation, Testing & Commissioning of Air & dirt Seperator as per specification Suitable for 250 mm Dia line size & 2040 GPM. at plant room complete as per technical specifications, drawings and requirements

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 7.16 TR / 3900 CFM For Reception Waiting & Corridor at First Floor

1

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. and above Bonded Treated Woven Glass Fibre for Outer covering of Insulation Material GC bonded applied by suitable adhesive. Density: 200 +/- 20 gsm Thickness: 0.18 mm / 7 mill, The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm

435

-

-

... More
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.

27

-

-

... More
Providing material and labour for laying average 60 to 70 mm thick machine cut polished Green kota stone slab of size upto 0.9mt length with uniform thickness double side polished at edges for parapeet wall coping, window sills, over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry or stone fixing adhesive including rounding of exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be pencil sharped and in even thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. Sample shall be approved before execution. Sample and mockup shall be approvd procurement of material.

110

-

-

... More
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 51 to 77mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.

50

-

-

... More
Providing material and labour for fixing of SS 304 grade brush finish 250mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

10

-

-

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required. as per technical specification etc. as required.

27

-

-

... More
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed. 40 mm

600

-

-

... More
Hole Packing treatment on service line Providing material and labour for applying total packing treatment on any type of pipes comes into water proofing area for all floor, all height as directed by engineer in charge as follows : Preparing the inside surface of core and Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Applying a coat of styrene- butadiene based polymer coating using Styrene Butadine Polymer bonding agentto enhance adhesion between the packing material and other surfaces. Packing the gap using non shrink cement polymer based grout using Non-shrink cementitious grout upto the surface of the bore whilst the bonding agent is in tacky state before application of water proofing treatment. Treatment shall be executed by same agency with same manufacturer's product. Warranty includes in water proofing item.

352

-

-

... More
Providing material and labour for fixing fixed vision panel glass in fire rated door as per manufacturers recommendation with a G.I. beading, & special ceramic tape/ gasket of approved make etc complete for all floor all height as directed by engineer in charge. The glass should be 6mm clear borosilicate fire rated glass of 2 hour rating.(Actual installed glass size (with two decimal) to be measured for payments).

2

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 65mm dia.

68

-

-

... More
Supplying, laying , testing and commissioning of 3 Core X 1.5 Sqmm Flexible Cable (per DDC to UPS Power Supply). as per technical specification etc. as required.

1250

-

-

... More
Supply, installation, testing and commissioning of First- Aid Hose Reel equipment with M.S. construction spray painted in post office red, conforming to IS:884 with up to date amendments, complete with the following as required. (a) 36 m. long, 25 mm dia. water hose thermoplastic (Textile reinforced) Type-2 as per IS:12585. (b) 25 mm dia gun metal globe valve & nozzle (c) Drum and swinging type fixing brackets on the wall. (d) Connections from riser with 25 mm dia. Gun metal ball valve.

24

-

-

... More
Sec.4.0 Masonry works Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in foundation and plinth in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.

1276

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 50 mm dia.(32 mm thick insulation)

385

-

-

... More
Mechanical Anchor : Providing material and labour for drilling, cleaning hole and fixing mechanical anchor of size 10 X 120 of approved make and suitable for fastenings both on concrete & masonary/aerated blocks. Anchor comprises of 10 mm diameter Polyamide PA 6 grade sleeve and of 7 mm diameter double threaded 6.8 grade Hex head double threaded screw made of carbon steel galvanized to minimum 5 microns. Fixing methodology shall be followed as per manufacturer’s guidelines. for all floors, all height as directed by engineer in charge.

50

-

-

... More
Extra for providing material and labour for Hot dip galvanizing work confirming to IS 4759/ 2629/ 2633 with zinc of 610 GSM thickness on Cable tray, Railing, Handrail, facade framing, supports for mechanical equipments, garbage box, Street furniture and similar works etc made from solid flat, bar, RHS, SHS, tubular hollow sections etc. as per the drawing and as instructed by engineer in charge. The rate shall include preparing the surface by shot blasting/ acid washing prior to hot deep galvanizing, labor, tools, machinery etc complete (Sample to be approved). The weight of steel sections before galvanization shall be measured for payment. The cost of steel sections shall be paid for separately under relevant item.

100461

-

-

... More
Providing material and labour for fixing CRS (Corrosion Resistance Steel) - FE 500D reinforcement for R.C.C. work including cutting, bending, binding with 18 SWG -1.22 mm GI wire and placing in position etc complete for all floors, all levels, all heights/ depth as per drawings, specifications and direction of Engineer in Charge.

2711750

-

-

... More
Sec.16 Signage Works SS letter sign: Providing, Making and fixing 150mm high SS 304 letter with back lited by LEDs/ SMD lightings behind the text made of 3/4" SS 304 channel (1mm thick) for signage in Gujarati, Hindi and English languages and the font style as approved sample or as per design and drawings. It shall be made from ISI Brushed S.S. 304 using Water jet / CNC cutting machine. It shall be fixed on the wall with chemical anchor fastener at any level any height. All Edges and corners shall be smoothened. Width of the letter shall as per the proportion of the word for depth 1". Stainless Steel Patti shall be argon welded. Duco paint of approved make, shade in required coat with necessary primer and putty shall be applied on external surface of letter. It shall be paid in as per alphabet no. In Gujarati/ Hindi language one letter shall considered with its contents (i.e. Kano, Matra etc.) i.e. 'chhi' letter in Guajarati shall be considered as one letter. Height of letters may vary + 3" shall be included in quoted rate. The rate shall be inclusive of scaffolding, drilling, adhesive material etc. complete for all heights.

120

-

-

... More
CABLE TRAYS Supplying and fixing following sizes of GI Ladder type cable trays including couplers,fittings and other accessories as required, and duly suspended from the ceiling with suspenders/fixed on ceiling / walls on fastners etc as per specifications complete as required. 600 x 105 mm

40

-

-

... More
Supply, installation, testing and commissioning of GM Single headed oblique type Hydrant valve (Internal & External) with instantaneous gun metal cuplings of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank pvc cap and chain as required.

30

-

-

... More
Providing and arranging in position 3 seater Sofa of approximate size 2000mm (W) x 900mm (D) x 450mm seat height x 800mm total height of Pisa of Godrej or equivalent with knock down construction system. The seat shall be made of pu foam in required layer with densityof 28 to 32 ± 2 kg/cu.mtr having upholstered with fabric or leatherette as per selection. The back shall be made of pu foam in required layer with densityof 23 to 28 ± 2 kg/cu.mtr having upholstered with fabric or leatherette as per selection. Understructre shall be made up of 12mm thick hot pressed plywood with zigzag spring assembly Leg for sofa shall be a welded assembly made in stainless steel tube & plate.

10

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. AUTO BALANCING VALVE complete with Flanges Nutbolts and Working parts 125mm dia.

6

-

-

... More
Providing and arranging in position semi fowler bed with removable head, 2 seactions 100mm thick Mattress, castors and PP foot board of Ayush plus of Godrej or equivalent. Bed shall be of approximate size (L) 2265 x (W) 900 x (H) 610mm. Two function bed with adjustable backrest 70deg & upperleg rest 24degHead board and foot board having curved profile. The head and leg board should have 4 nos mosquioto pole holder. Lying surface shall be made of 1mm thick CRCA sheet having 4 sections for bed profiling i.e. back adjustment, fixed pelvic section, upper and lower leg adjustment. The bed should have urine bag holder on both side of the bed. Mattress should have 2 section 100 mm mattress and made of 40 density pu foam and placed in platform. The mattress should have high end heavy hellium cover which is water resistant, x ray permeable, fire retardant. The manufacturer should compilant with ISO 9001, 14001, OHSAS 1800 and CE certification. Bed shall be with knock down construction system and made of MS EWR tube and CRCA steel. All metal components should be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbial epoxy polyster powder coating

342

-

-

... More
Providing material and labour for applying (Synthetic) Plastic emulsion paint (minimum 2 coats) having VOC (Volatile Organic Compound) content less than 50 gm/ltr on newly/ existing dry interior plastered surface including ceiling, roof etc. at all heights/ all levels/ all surfaces to give an even shade on prepared (putty and primer work) surfcae. Sample to be approved before starting of the work by Architect/ EIC. Rate shall be inclusive of the cost of scafolding but excluding the cost of primer and putty work.

82093

-

-

... More
GI Open Cell 150mm x 150mm Providing and fixing in true horizontal level Open cell GI lay-in ceiling tiles with border panels forming flush-tegular edge of size 600x600x38mm having Fire Performance CLASS A1 as per EN-13964. The tile shall be powder coated of approved colour having powder coat thickness ranging from 60-80 microns. The tile with cell size of 150mm x 150mm shall be laid on Suprafine 38 with 15 mm wide T-section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 12.5 Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of same make. Warranty Certificate and Test Reports for Fire rating shall be provided by Vendor. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum. Installation to be carried out by Trained Installation team and as per recommended procedure of approved manufactur. SUSPENSION SYSTEM accessories consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum pull strength of 110 kgs. (Adjustable hook clips of 0.7mm thick, galvanized spring steel can also be used for installation purpose as an additional accessory. The adjustable clip also consists of a 4 mm aquiline wire to be used with the main runner).

2046

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-A SECOND FLOOR HVAC PANEL As per Single line diagram

1

-

-

... More
Notes for Hardware : Supplying and fixing heavy quality fixtures and fittings for doors, windows, ventilators, partition wall, cabinets with necessary screws, nails, machine pins etc at all floor/ all levels/ all heights complete. Sample shall be approved by Architect before execution. As per description, SS hardware shall be of 304 grade or 316 grade as per item description and as per approved sample. The fixture & fastenings shall be provided as under : Providing material and labour for fixing single/ double action hydraulic floor spring with SS cover plate & adjustable concealed casted top pivot (two piece) and bottom strap of approved make for wooden/ aluminium doors of specified capacity with minimum one year guarantee. Rate shall be inclusive of cutting of floor neatly, grouting the floor spring & cleaning/ polishing the floor & maintaining in good working condition until defect liability period. In case of Aluminium shutter bottom arm of floor spring & top pivot shall be firmly fixed in the aluminium members using required size of teak wood by making rabbet in the wood. The Floor Spring shall conform to EN 1154. a) Hold open having for shutter width upto 1200mm with standard spindle and cover plate. Closing force complying with EN 1154 2-4

14

-

-

... More
Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Supreme / Ashirvad. c) 32 mm nominal bore

15

-

-

... More
Providing and arranging in position Single Static Drive Cover Unit 2 Bay for OPTIMIZER of Godrej or equivalent having approximate dimensions 1800mm(W) x 380mm(D) x 2000mm(H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS : 513 . Each body shall have a main unit plus add on units (1,2,3,4,5). Shelf construction shall be made from CRCA steel 0.8 mm thick IS :513. Uniformly distributed load capacity of 80 Kg. Undercarriage shall have construction in welded frame made of HR sheet 3.15 mm thick conforming to IS : 10748. Finish shall be epoxy polyester powder coat of approved color & shade with a dry film thickness of minimum 40 microns. The Movements shall be Drive Type configuration for mechanically through a PU Drive Wheel and Sprocket -Chain-Tensioner arrangement mounted rigidly onto body size. Each movable undercarriage shall be provided with 2 rollers on the shaft for driving , 2 antifriction ball bearing for rolling and 4 antifriction ball bearing for guiding between rail. Fittings shall be centralized locking arrangement (recess handle) through locking stiffener mounted onto back of single last unit. Door locking shall be having hinged doors of recessed die cast handle cum lock giving 3 way locking through a lever & shooting bolts. The label holder shall be made from 2 mm thick clear transparent acrylic sheet. Total no. of loading levels per understructure shall be 10 for SD2. Single static drive cover unit shall contains all required arrangement i.e. handle for hinge door, knob for manual operation, guide channel, End stopper, Easteners, facia, trim etc.

12

-

-

... More
Toilet waterproofing Providing material and labour for carrying out waterproofing treatment to sound concrete surface of toilets, sunken slabs, corridors, wet areas etc. after proper surface preparation to remove loose dust, dirt etc., repairing of cracks (if any) using polymer modified mortar, carry out cementitious injection grouting at leakage points modified with Plasticized Expandive Grout Admixture @ 225 gms per bag of cement, carry out 50 mm thick cement mortar (1:3) vatta/ corner modified with Styrene Butadine Polymer bonding agentat dosage of 2.5 Ltr per 50kg cement, Pre-dampening concrete surface, mixing and application of two coats of Elastomeric Polymer modified cementitious waterproofing coating by incorporating alkali resistance 45 gsm glass fibremesh between 1st and 2nd coat using suitable brush or roller as per coverage etc. complete for all floor al height all level as per manufacturer’s specification and as directed by engineer in charge. Cured Polymer modified cementitious waterproofing coating shall comply with ASTM D4060, ASTM D4541, ASTM D638,ASTM C836 and possess below properties: Mixed density : 1.68 g/cc, Adhesion to concrete- 1 N/mm2, Non-toxic, Static crack accommodation-1 mm Water proofing system shall be executed by only approved applicator of approved brand and under strictly supervision of technical fellow of manufacturer. The rate includes giving 10 year guarantee for waterproofing on a Rs.100/- stamp paper in approved proforma.

884

-

-

... More
Providing material and labour for laying Kota chips coving and skirting up to 30 cm height, rubbed and polished to granolithic finish, top layer 6 mm thick with kota stone chips of sizes from smallest to 4 mm nominal size, laid in cement sand mix 3:1 (3 cement : 1 sand) by weight in proportion of 4:7 (4 cement marble powder mix : 7 kota chips) by volume with 18 mm thick backing having under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 coarse sand) and remaining 6mm thick cast in situ terrazzo layer in Dark shade pigment with ordinary cement. Rate shall be inclusive of laying of terrazzo (Base and topping) to line and level, Grinding, polishing, grouting, hardening and sealing of concrete floor for all levels/ all heights etc. complete as directed by engineer in charge.

474

-

-

... More
Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm outside layer and 0.8mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan with 50 mm static, 4 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), with Mixing box, filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, belt with TEFC drive motor (Eff-1) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, supplied with factory fitted matching size 2 way ON / OFF actuator type Brass / Control valve / Cu piping with required couplings and ends flanged to fit CHW In / Out piping, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan and duly internally wired and tested. Followings are capacities. (With 5 Micron Filteration) 1.94 TR / 1100 CFM For Lab at First Floor

3

-

-

... More
Providing material and labour for fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut Powder coated aluminium sheet 2.5mm thick (minimumthickness of powder coating 50 micron) and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge.

253

-

-

... More
Sec: 2.0 PCC & RCC works Providing material and labour for laying Autoclave Aerated Concrete Block chips/ bats cement concrete in 1:4:8 (1 Cement : 4 Coarse Sand : 8 graded Autoclave Aerated Concrete Block chips/ bats) for sunk filling grade including compacting, finishing, curing etc. complete as directed by engineer in charge.

752

-

-

... More
Providing and fixing Signage at Building terrcae or at other place made of - 1) 3mm thick Acrtlic to Acrylic cover letter in white colour having 100mm embossed in text or logo as per drawing or as suggested by EIC. 2) ACP/ GI reverse channel letter to uphold front letter 3) All side embossed by 90mm Aluminium channelium illuminate from front side 4) IP 67 grade water proof LEDs/ SMDs modules with 3 year opt door warrenty 5) Water proof/ Rain proof power supply with complete wiring including on site fixing for all height all level 6) Signage panel shall be fixed on MS struxcture, which shall be paid i relavent tender item. 7) installed signage board area shall measured for payment.

10

-

-

... More
Supply, Installation, Testing & Commissioning of Drop Bolt Or EM Door Lock as per Door type & site Location requirement.

1

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 65mm dia.

4

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 18.2.3 - 2025 (25mm OD) pipe

105

-

-

... More
Providing material and labour for laying shot blasted Non-interlocking (factory made) high density 60 mm thick M35 grade any colour brick type paver blocks of size 200mm x 200mm/ 200mm x 100mm of approved make and shade for footpath, parking areas, service lanes and other areas as mentioned in the drawing including average 50 to 80 mm thick bedding layer of coarse sand below paver block. Laid paver block shall be mechanically compacted and as directed by Engineer in charge. The work shall be executed in line and level by skilled mason of flooring work only for paver blocks. It should be laid in such a way that the No cutting of the paver block to be necessary and if required, cutting of paver block by machine cut only. The Finished surface of the paver block shall have coarse sand texture finish. Sample to be approved before starting of the work by Architect/ EIC.

200

-

-

... More
Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm outside layer and 0.8mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan with 50 mm static, 4 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), with Mixing box, filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, belt with TEFC drive motor (Eff-1) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, supplied with factory fitted matching size 2 way ON / OFF actuator type Brass / Control valve / Cu piping with required couplings and ends flanged to fit CHW In / Out piping, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan and duly internally wired and tested. Followings are capacities. (With 5 Micron Filteration) 4.12 TR / 2450 CFM For Lab at First Floor

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic type Level Transmitter (5mtr. Depth )

20

-

-

... More
Supply, Installation, Testing and commissioning of 63 mm GM Branch Pipe with 20mm GM nozzle conforming to IS:903, suitable for instantaneous connection to interconnect hose pipe coupling as required.

24

-

-

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. as per technical specification etc. as required.

710

-

-

... More
EARTHING Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

800

-

-

... More
Fire Stopper SITC of Fire stop mortar system , with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like cables/cable bundles, cable trays etc. The system shall be UL listed & classified and product shall bear the UL and FM approval logo on the packing. If none of UL test certificate comply with actual application, an EJ document (as per IFC Guidelines) prepared by a qualified personnel and based on nearest third party tested & approved systems like UL test certificates & in accordance with IFC guidelines shall be producted by manufacturer. A firestop submittal shall be produced by manufacturer , in accordance with approved passive fire protection method statement, for technical approval. Firestop installation shall be done by manufacturer's Accredited Firestop Speciality Contractor (HAFSC) and in accordance with manufacturer guidelines and UL system test certificates or approved EJ document. .

6

-

-

... More
Chemical Anchor: Providing material and labour for fixing chemical anchor medium to heavy duty injection adhesive for Anchor fixing in Dry conditions and HILTI HIT-HY 200 + HIT-V rods of size 16mm x 200mm of HILTI or equivalent as per drawing or as instructed by EIC. The system should be made of two foils consisting of resin and Hardener foil pack. The system can be used for threaded rods HIT-V rods or equivalent rods. The installation and the setting instructions should be strictly followed as per the manufacturers recommendations. Rate shall be inclusive of injection adhesive and fastner rod of same make.

50

-

-

... More
Supply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 600 x 100 made out of 2 mm thick ladder type

150

-

-

... More
Providing and fixing to wall and ceiling ISI Marked (Embossed) 65mm diameter of Medium Duty 'B' Class G.I. pipes as per IS: 1239, complete with cutting, threading, all fittings such as unions, bends, tees, etc, Teflon tape over threaded joints, Hilti anchor fasteners, G.I. threaded rods, double sided G.I. clamps, etc. including making good the wall and ceiling complete as directed by the Engineer-in-charge.

390

-

-

... More
Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size.

77

-

-

... More
Supply, installation, testing & commissioning of Ceiling Mount Cassette type Exhaust Fan. - 100 CFM

12

-

-

... More
Supplying and erecting, testing and commissioning of Hanging Light Point -Wipro or equilavent (Type-ORBIT LED) 34W(CODE-LM-71-441-XXX-57-XX)- or equivalent as per apporved make list.

27

-

-

... More
Providing material and labour for fixing SS 304 adjustable friction windows stays of size 355 X 19 mm of approved make with necessary stainless steel screws to the side hung or top hung windows etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

50

-

-

... More
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 77 to 102mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.

50

-

-

... More
Providing and arranging in position storage unit having Sliding door of VSDU-2 of Godrej or equivalent of approximate size 900mm x 450mm x 700mm. Storage unit shall be made out of CRCA steel - D grade as per IS 513 having epoxy poyester powder coating of 50 microns. Storage unit shall be of knock down construction with adjustable self arangement and all required hardware i.e. handle, lock (5 lever), roller, ball bearing etc.

82

-

-

... More
Data Networking - Fiber Optic Cable and Components Supplying, installation, testing and commissioning of outdoor 6 core armoured single mode fiber optic cable for outdoor connectivity where ever required in prelaid conduits / RCC hume pipes/HDPE/DWC, whichever maybe available etc. as per technical specification etc. as required.

150

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 150mm dia.

3

-

-

... More
Dismentling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats architraves, holdfasts and other attachment etc. complete and stacking them within all lead and lift.(ii) Exceeding 3 Sq.M. in area.

20

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 4500 CFM / 40mm Static Pressure for Dirty Corridor

2

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-D UPS POWER PANEL As per Single line diagram

1

-

-

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

5800

-

-

... More
Chemical Anchor: Providing material and labour for fixing chemical anchor medium to heavy duty injection adhesive for Anchor fixing in Dry conditions and HILTI HIT-HY 200 + HIT-V rods of size 10mm x 120mm of HILTI or equivalent as per drawing or as instructed by EIC. The system should be made of two foils consisting of resin and Hardener foil pack. The system can be used for threaded rods HIT-V rods or equivalent rods. The installation and the setting instructions should be strictly followed as per the manufacturers recommendations. Rate shall be inclusive of injection adhesive and fastner rod of same make.

50

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 300 mm dia.

3

-

-

... More
Supply, Installation, Testing, Commissioning of Outdoor type Ambient Temperature with Humidity Sensor with radiation shield , IP65 rated(Temp Range -30 to +50 °C, RH : 0-100 %). as per technical specification etc. as required.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Diesel Engine Driven (Stand By) fire pump suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, centrifugal, back pullout pump to ensure a minimum pressure of 3.5 kg / cm². at highest and farthest outlet at specified flow of 2280 lpm at 80m. head conforming to IS standards. b) Diesel engine of 1800-2200 RPM water cooled type with radiator conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 volts electric starting equipment, Diesel tank, exhaust pipe extended up to 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. vibration pad & other accessories as required for complete Installation of pump set.

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 1500 CFM

1

-

-

... More
M.S. Above Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / gaskets / Nut bolts etc., and laying on the surface including painting with one coat of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required: 65mm dia

576

-

-

... More
Supply, Installation, Testing, Commissioning of Water Type absolute Pressure Transmitter

9

-

-

... More
Supply, Installation, testing & commissioning of Insulation of above Expansion tank with Nitrile Rubber with Woven Glass Fibre Covering insulation complete as per technical specifications, drawings and requirements

1

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe & PN 16 pressure rating for hot water circulation as specified. 150 mm dia.

3

-

-

... More
SITC of 3 compartment Access outlet / service box of 250 x 250 x 60-75 mm with all accessories made out of high pressure die cast material suitable for above race ways .

10

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 10.73 TR / 6150 CFM For Nurse Station & Passage at Second Floor

1

-

-

... More
Providing material and labour for fixing of expansion joint system for 100mm wide expamsion joint gap of approved make related with floor location as per drawings and direction of Engineer-In-Charge. The joints system shall be of extruded aluminum base members, self aligning/ self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor/ floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and match with finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates/ moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design. (Material shall conform to ASTM 6063). Rate shall be inclusive of stone fixing in between the system as per drawing. Cost of stone shall be paid in relevant tender item. Expansion joint system shall be as approved for all floor all level including scafolding etc complete as directed by engineer in charge.

149

-

-

... More
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (e) RG – 11.

450

-

-

... More
Providing material and labour for laying cement concrete pavement (of any thickness) with 1:2:4 (1-cement : 2-coarse sand : 4-stone aggregate 20mm nominal size) including curing, finishing with floating coat of neat cement complete at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge.

144

-

-

... More
Providing material and labour for fixing SS 316 grade butt hinge of average 100 x 75 x 3 mm - with ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge.

2444

-

-

... More
Supply, installation, testing & commissioning of Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of proper insulated copper tubing up to 5 RMT suitable for (Cost includes M.S. Stand, Gas Charging & Internal Copper Wiring & Remote Control) 2.0 TR Capacity

1

-

-

... More
SITC of of 1 compartement 100 mm x 38 mm, 1.6 mm thick, under floor metal trunking/race way with all accessories made out of hot dip pre galvanized metal coated steel sheet.

50

-

-

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required. as per technical specification etc. as required.

50

-

-

... More
Providing material and labour for fixing mirror polished average 18mm thick best quality Granite stone slab as per sample approved by Engineer in charge with edges rounded and mirror polished, of required size fixed as platfrom/ vanity counter by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement mortar 1:2 (1 cement : 2 coarse sand) as per drawing and as per direction of Engineer-in-charge. 75mm high facia shall be fixed at the edge of platform with epoxy or stone fixing adhesive as per drawing. All expose edges shall be champhered and mirror polished. Rate shall be inclusive of chasing, cutting, pencil sharped edges, edge polishing, making holes, curing, finishing, maintaining upto handling ovre the project etc complete for all floors all level etc complete as directed by Engineer Incharge. Installed area of platform and facia shall be measured for payment.

71

-

-

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

63

-

-

... More
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 75 mm dia.

50

-

-

... More
Floor indication marking Signage Providing, Making and fixing 1000mm dia circle and min 600 mm high letter made of 1" SS 304 channel (1mm thick) for signage in English languages and the font style as approved sample or as per design and drawings. It shall be made from ISI Brushed S.S. 304 using Water jet / CNC cutting machine. It shall be fixed on the wall with chemical anchor fastener at any level any height. All Edges and corners shall be smoothened. Width of the letter shall as per the proportion of the word for depth 1". Stainless Steel Patti shall be argon welded. Duco paint of approved make, shade in required coat with necessary primer and putty shall be applied on external surface of letter. It shall be paid in as per alphabet no. In Gujarati/ Hindi language one letter shall considered with its contents (i.e. Kano, Matra etc.) i.e. 'chhi' letter in Guajarati shall be considered as one letter. Height of letters may vary + 3" shall be included in quoted rate. The rate shall be inclusive of scaffolding, drilling, adhesive material etc. complete for all heights.

6

-

-

... More
Providing material and labour for laying hand cut/ machined cut natural rough finish 25 to 30 mm black kadappa Stone of approved quality, selected and sorted for uniform color & texture, in external work, pavement, pathway, tread, riser, ramp etc as per drawings of size upto 900mm in any shape, any pattern. Kadappa stone is to be laid over cement mortar 1:6 bedding of average 20 mm thickness with open grove. The rate shall also include providing groove of 5mm wide and filling the groove with epoxy + cementitious grout as per specification of approved make and shade and as per design and drawings & as per approved sample, including curing and cleaning with wire brush to remove excess cement on the sides of stone chemphering of exposed edges having polishing etc complete as directed by engineer in charge etc. complete for all places / all levels / all heights. Grouting of joint shall be paid in relevant item.

50

-

-

... More
Providing material and labour for laying cement concrete broom finish/ smooth finish pavement for plinth protection/ CC Road 100 –150 mm. thick with M25 concrete including giving a floating coat of 1:1 cement mortar, with Nominal temperature steel, tie bar, dowel bar as per MORTH specifications of section -6 etc complete as specified by the Engineer-in-charge. The rate shall be exclusive of reinforcement steel, dowel bar etc. The same shall be paid in relevant tender items. Rate shall be inclusive of concrete (to be laid in alternate panels size shall be apprx 4.5mt X 5.0mt ) with fair finished steel channel formwork, saw cutting of construction & contraction joints in width 3 to 5 mm x 1/4 to 1/3 thickness of pavement, filling the 25mm x 20 mm (BXD) expansion joint approximately at every 30 mt with readymix bitumiNous filler as per sample approved & directed by engineer incharge etc complete. Screened Sand to be only used.

50

-

-

... More
Supplying and erecting, testing and commissioning of 20W LED batten Surface Mounted Industrail Corroson proof Fixture Ip 65 -Make Crompton or equilavent (IPFC111LT8-16 1X 20W)

73

-

-

... More
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. 200mm dia.

5

-

-

... More
Providing material and labour for fixing 120 min fire rated SS 304 Ball Bearing Butt Hinges 100mm x 75mm x 3 mm CE marked for fire rated metal door of approved make with necessary screws etc. complete as recommended by manufacturer for all floor all height and as directed by Engineer in Charge.

36

-

-

... More
Supplying, installation, testing & commissioning of addressable phone control module complete as required. as per technical specification etc. as required.

27

-

-

... More
Supply, Installation, Configuration, Programming of Web Based Energy Management & Reporting Tool software for Monitoring Building efficiency & Customization of Energy Management (For 40 Meters) Application that will Communicate with the Main Framework having Capability of Energy Profiling, Energy Mapping, Load Calculations, Predictive Energy Analysis, Energy Spectrum Analysis etc as per Functional Specifications of the Bid for 50 points. Bidders Must Consider all Application Modules and Licenses to be Part of the Bid. as per technical specification etc. as required.

1

-

-

... More
Providing material and labour for Excavation of foundation from 5.0 mt to 7.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in the campus for all lead, all lift/ depth and back filling foundations, the trenches, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.

50

-

-

... More
(e) 4C X 10 SQ. MM. CU XLPE CABLE

150

-

-

... More
Providing and placing in position Metal Single bed of Godrej or equivalent of approximate size 2000mm (W) x 970mm (D) with Headboard panels are made of 18 mm thick Prelaminated Particle Board and edge banded with 2 mm thick PVC edge banding. Bed leg frame structure and head board structure shall be made of MS having powder coated finish of 50 micron. Mattress holding bracket shall be made of CRCA sheet. Bed shall be with Knock Down construction.

15

-

-

... More
Digital Evac / Public Address System. Supply, Installation, Testing and Commissioning of 8 zone IP based digital Voice Alarm controller expandable upto 128 zones. The voice alarm controller should be able to connect directly over Ethernet. It should have functions like the audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. The Voice alarm controller should also have the following functions, 255 Priorities, Time schedule broadcasts, Its own PTT microphone, Capable of amplifier redundancy, 8 trigger inputs/outputs , as per technical specification etc. as required.

1

-

-

... More
Supply, installation, testing and commissioning of Non Return Valve with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified: 150 mm dia.

8

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 950 CFM

2

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-C HVAC PANEL As per Single line diagram

1

-

-

... More
Supply, installation, testing and commissioning of C.I. Gate valve (PN 1.6) as per IS:14846 complete as required: 150 mm dia.

8

-

-

... More
Providing and fixing SS Floor Cleanout (FCO) plug of approved brand and with SS Square Frame/ Round Frame with Flat Round Cover with Rubber Seal & SS Screw jointing as per manufacturer recommendation or per approval of the Engineer-in-charge. ii) 128mm x 128mm Square Top for 100 mm dia pipe. Make:Chilly; Model No. COS 05 or Similar or Equivalent Make.

30

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B FIRST FLOOR EQUIPMENT NON UPS PANEL As per Single line diagram

1

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 80mm dia.

1

-

-

... More
Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.

16972

-

-

... More
Dismentling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats architraves, holdfasts and other attachment etc. complete and stacking them within all lead and lift.(i) Not exceeding 3 Sq.M. in area.

20

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 200 mm dia.(32 mm thick insulation)

290

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 8.80 TR / 4850 CFM For Reception Waiting & Corridor at Ground Floor

1

-

-

... More
Providing material and labour for fixing factory made and pressed laminated 35mm thick flush door shutter of specificied thickness made of ISI marked non decorative type flush door shutters confirming to IS- 2202 (Part 1), core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers (IS 710 Grade) on both faces of shutters having 1 mm thick decorative type laminates of approved make, shade, finish on both faces of shutter fixed with phenol formaldehyde synthetic resin type adhesive conforming to IS 848 including providing and fixing external lipping with 2nd class teak wood battens, exposed (37mm x 12mm)/ concealed (35mm x 12mm) on all edges of door shutter as required with 2 coats of synthetic enamel painting including 1 coat of wood primer & lapi/ lacquer polishing with primer to all exposed side of lipping, all as per approved drawing, for all floor, all level all height etc. complete as directed by Engineer-in-charge. Measurement including lipping shall be considered for payment. Necessary hardware like hinges, pivot, handle, tower bolts, locks etc shall be separately measured and paid in the relevant tender items. Cost of laminates shall be paid in relevant tender item.

50

-

-

... More
Supplying and erecting, testing and commissioning of 46W 8' Feet LED Recessed Mounted indoor Channel Linear Lights Fittings with diffuser-Make Philips make Channel RC780B LED 52S-6500PSU W6L240ODSIor equivalent as per apporved make list.

53

-

-

... More
Supplying and placing Glass top corner/ side Table of PISA of Godrej or equivalent of Size 600mm ( W) x 600mm ( D) x 350mm ( H). Table shall be made of 12mm thick black tinted toughened glass and fitted on SS under structure with knock doen construction.

10

-

-

... More
Supplying, installation, testing and commissioning of UTP CAT6 24 ports capacity gigaspeed patch panel, all ports loaded with individual RJ-45 IOs. as per technical specification etc. as required.

21

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 400 CFM

1

-

-

... More
ELW 15.00Light Fixtures and Fans Supplying and erecting, testing and commissioning of 18WLED recessed Mounted Down Lighter -Make Crompton ( Type-LCDE -18-CDL) or equivalent as per apporved make list.

709

-

-

... More
Providing and fixing Electronic Door Lock of approved make for wooden door having thickness of 35 to 50 mm of following specifications. 1) Dead Latch Lock Type with 30 RFID Cards and 78 Pin Codes 2) 2 keys for mechanical over ride function 3) Shall have dimensions of Front Body 37.97 (D) X 70 (W) X 170 (H) mm and Back Body 25.48 (D) X 70 (W) X 179 (H) mm 4) low battery indicator and emergency power supply 5) anti panic egress function from inside Contractor Shall provide 1 year manufacturer’s warranty against material and workmanship. Rate shall be inclusive of lock, nesscry fixing hardwarer, cutting of wooden door shutter, making good etc complete as directed by engineer in charge

5

-

-

... More
6/16 A x 250 V switch socket point on one switch box with 2.5 sqmm flexible wires and phase and neutral and 1.5 sq nm flexible Cu. wire as earth wire. The rate should include conduiting upto DB.

2349

-

-

... More
Supply, Installation, Testing and Commissioning of IP Phone with display as per tender specification etc. as required.

17

-

-

... More
Providing, fixing including testing and commissioning of Drain valve & assembly with 2 nos. of 1" ball valve, sight glass, internal 1" pipe & required fittings. 25mm dia

24

-

-

... More
Providing and arranging in position CRASH CART of Godrej or equivalent. overall dimension of L 855 W 405 H 1520 mm. Top sheet, middle sheet, bottom sheet, frame bar shall be made out of SS 304 garde in required size. MS plated Cylinder case should be used welded with cylinder holding unit to hook giving the curve bend at the bottom to hold the cylinder. SS 304 grade pipe of section 12mm should be used to provide provision to mount IV rod. High endurance anti static, plastic injected molded 4 swivel castors of dia 125mm should be used & should have provision for diagonal locking. SS 304 handle pipe should have section of 25.4mm with length of 365mm & should have thickness of 1.2mm giving a glossy finish. SS 304 tubular frame should have five different colored removable bins mounted on top shelf and two polystyrene lockable storage units with three drawers each. The top drawers should have containers of different sizes. Thermosetting epoxy polyester with semi gloss finish powder coating must be used.

17

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / Hot Water multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built 2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with "Y" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 600 CFM

14

-

-

... More
Providing material and labour for laying machined cut/ hand cut natural rough finish 25 to 30 mm Red Mandana Stone of approved quality, selected and sorted for uniform color & texture, in external work, pavement, pathway, tread, riser, ramp etc as per drawings of size upto 900mm in any shape, any pattern. Red Mandana stone is to be laid over cement mortar 1:6 bedding of average 20 mm thickness with open grove. The rate shall also include providing groove of 5mm wide and filling the groove with epoxy + cementitious grout as per specification of approved make and shade and as per design and drawings & as per approved sample, including curing and cleaning with wire brush to remove excess cement on the sides of stone chemphering of exposed edges having polishing etc complete as directed by engineer in charge etc. complete for all places / all levels / all heights. Grouting of joint shall be paid in relevant item.

50

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 8.24 TR / 6150 CFM For Nurse Station & Passage at First Floor

1

-

-

... More
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For all Floor in cement mortar 1:5 (1 cement : 5 fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.

50

-

-

... More
Providing material and labour for fixing in position SS 304 - 18 x 16 mesh and 32gauge Mosquito net of any size any shape having 50 micron pure polyster powder coating of approved make and shade for aluminium sliding shutter/ fixed shutter or in front of aluminium louvers as per approved shop drawing prepared by contractor. Jali shall be fixed with SS304 grade screws and fasteners required to tighten the Jali/ Net including fxing channel, EPDM quality rubber/ silicon sealant etc complete for all floors, all levels, all heights as directed by engineer in charge. Only installed area of mosquito net shall be measured and paid in Sqm without considering any westage. All aluminium sections shall be paid under relevant tender item.

127

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 80mm dia.

27

-

-

... More
Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. a) For 15mm & 20mm dia pipes - 19mm x 22mm Nitrile Rubber Plain Tubing

90

-

-

... More
SEC:5 Doors and Windows work ALUMINIUM WORKS - Providing material and labour for fixing in position frames, shutter for any type of aluminium work for any type of door, window, partition, made out of any type of aluminium sections of approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors, all levels, all heights, all shapes, all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material. All loose material shall be approved. Mockup of one/two window shall be executed as per approved shop drawing with all hardware. Work shall carried out as per the approved shop drawings, approved mock-up and approved sample. Actual weight of installed Aluminium sections (for using fabrication without considering any wastage) shall only be measured and shall be considered for the payment. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. Rate shall be inclusive of providing aluminium sections, cutting, fabrication, errection and fixing to the best workmanship manner, including 1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame; 2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatible microwave cured EPDM rubber; 4) Dash Anchor fasteners of HILTI HRDUGT or equivalent for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of section for connecting style and horizontal rails; 6) providing and fixing packing (rough ground) in full periphery/ at every 600mm c/c with average 6 mm thick PVC spacer/ compact sheet of width (equal to section width less 30mm for backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required. and excluding the cost of necessary hardware and Glazing or Infill material.

58817

-

-

... More
SITC of 40 A FP ELMCB(ELCB+MCB) (100mA)

4

-

-

... More
Providing, casting, hoisting, installing in position Precast Reinforced cement concrete (M25) Bench as per design and drawing having 40mm thick mirror polished kota of approved shade on top. groove of same width as mortar thickness shall be provided between top kota stone and concrete top as per drawing. Remaining surface of bench shall be expose rcc work. All edges of kota shall be champhered and polished. Rate shall be inclusive of RCC, reinforcement and kota work with all material, labour for making, fixing, loading, unloading, hoisting, placing, polishing etc complete as directed by engineer in charge. Sample shall be approved before execution of work. Size of Bench - 1500 L x 450 mm W x 380mm H (100mm thick seat) with tappered solid base (1100mm x 200mm at bottom and 1200mm x 300mm at top)

100

-

-

... More
Supplying mterial and labour for laying of following size DWC HDPE pipe of 160mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge.

100

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 400 CFM

1

-

-

... More
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq. mm) for integration within AHU room Actuator

16

-

-

... More
Providing and fixing full thread G.I. Tank Nipple (medium duty) as per IS: 1239, including drilling holes in the tanks at required levels, inserting the coupling in place, sealing the hole with silicon sealant, attaching the hex nuts on either side of the coupling as directed and approved by the Engineer-in-charge. (C) 32mm diameter

20

-

-

... More
Providing material and labour for fixing in position 80 mm thick factory made machine batched & machine mixed Solid Precast RCC Rectangular Covers on cable trench of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.

100

-

-

... More
Providing material and labour for laying average 25 mm thick machine cut polished Green kota stone slab of size upto 2.1mt length with uniform thickness for tread, window jambs & sills, coping over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including pencil sharped exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be pencil sharped and in even thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. Sample and mockup shall be approvd before procurement of material.

518

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 1000 CFM

3

-

-

... More
Providing and fixing recessed type ceramic soap dish of size 150mm x 150mm, including chasing in the wall, setting the soap dish in white cement in the location and at levels as directed by the Engineer-in-charge.

100

-

-

... More
Providing & erecting approved make Time Attendance Module (TAM) Having following features “(A) Comprehensive Time Attendance and Leave Management Software Module “(B) For 500 Users [AS per COSEC GE PLATFORM USERS] “(C) Attendance and leave Policy Creation “(D) Integration with payroll and HRM “(E) Shift Schedule, Holiday Schedule and Past Adjustment “(F) Manually Attendance Correction “(G) Leave/Tour Application and approval “(H) Report and Charts Generation

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-C TERRACE HRU PANEL - OUTDOOR TYPE As per Single line diagram

1

-

-

... More
Providing material and labour for laying Bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ min 5.4 % of mix, transporting the hot mix to work site, laying with a self-propelled paving machine equipped with an electronic sensing device to the required grade, level and alignment, rolling with 8-10 tonne static weight or vibratory roller or with a pneumatic tyre roller of 12 to 15 tonne weight to achieve the desired compaction as per approved design mix etc complete including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.

100

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 3750 cfm, external static 50 mmwg Exhaust air fan - 3800 cfm, external static 50 mmwg

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 4300 CFM / 6.12 TR With 1.50 kW Strip Heaters & Humidistate For CT Scan Room at Ground Floor

1

-

-

... More
Coustom Made Furniture Providng, fixing and fabricating reception counter, nurse station of 750 mm wide at working level (750mm) and 300mm wide at service level (1050mm) with partial bottom storage with drawer made out of metal framing with PU paint and primer, covered with 19mm thick of 303 grade plywood, 1.0mm thick laminates of approved make and shade etc. complete including all accessories like cable manager/ electrical points/ hinge, handles, telescopic channel as per drawing at all floors, all levels etc. complete as directed by engineer in charge. Contractor shall prepare shop drawing based on tender drawing for get approved from engineer in charge before fabrication of furniture. All consumed material shall be of approved make and shade. Sample of all material shall be get approved from Architect and engineer in charge. All ply and lamination pressing shall be factory machine pressed and fabricated with proper moulding work. All exposed edges shall be covered with second class teak wood beading followed with melamine polishing of approved make and shade. At the time of installation, contractor shall take care of all services co-ordination.

76.4

-

-

... More
Supplying and placing Glass top Center Table of PISA of Godrej or equivalent of Size 1100mm ( W) x 600mm ( D) x 350mm ( H). Table shall be made of 12mm thick black tinted toughened glass and fitted on SS under structure with knock doen construction.

15

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 9.12 TR / 4540 CFM For Reception Waiting & Corridor at Ground Floor

1

-

-

... More
Supply, Installation, Testing and Commissioning of Nurse Station It should have 6.5" TFT wide viewing angle resolution of 800 x 480 touchscreen display. It should show all the call according to VDE 0834 and option of Collective announcements; Staff announcements, ward interconnection. It should be connected to System switch with TCP/IP POE inteface. The module must support VoIP speech comuunication. It should be connected to connection module with intelifix connection. It must fufill all the requirement mentioned in tender document.

2

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 32 mm dia.(19 mm thick insulation)

300

-

-

... More
Supply, installation, testing and commissioning of Non Return Valve with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified: 65 mm dia.

1

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 125mm dia.

32

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes at an average distance of 1.2 meters centre to centre, by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

220

-

-

... More
Supply, Installation, Testing & Commissioning of Network Video Management & Monitoring Software (NVMMS) system with distributed architecture to collect, manage and present video from all the cameras and supports emerging technologies in the industry, like 4K resolution, H.265 video compression codec. The NVMMS shall have option to support database redundancy and 1+1 and N+M NSM failover features for unforeseen/maintenance scenarios for increased system reliability. NVMMS shall support NSM's licenses 128 cameras, 3 user clients without any additional version upgrade. The NVMMS should support network joystick controller, GPU rendering support for H.264 and H.265 decoding , video on demand, Adaptive video throttling, rule engine, operatore role management, server based Video Motion Detection (VMD), timeline search, Preview search, synchronous playback from all NSMs, monitor wall support, HTTPS, SSL base, smart web client, secured firewall configuration, password expiry, non-recoverable password; support ANDROID, iOS phones, seamless integration with intgegrated security platform which provides HSDK, API for further integration with 3rd party systems. as per specification. as per technical specification etc. as required.

2

-

-

... More
9.00 Furniture Works Providing & fixing Roller blinds comprising 100 % Polyester, Weight 164GSM with Thickness 0.3mm, Width 220 cms of Vista Victoria or equivelant. The roller mechanism operate with Control unit is made of high strength reinforced plastic. The clutch is of wrap spring design. High carbon steel springs are provided to transmit motion from driving to driven members of clutch mechanism. Clutch is operated directionally by the use of endless beaded chain. Clutch never needs any adjustment. The Idler is of high strength reinforced plastic, consisting of a centre shaft. The idler is mounted on the bracket by using a plastic lock. The metal sleeve inside the plastic lock provides bearing surface for the centre shaft, which rotates freely, providing smooth, quiet and long wearing operation in a roller tube of 32mm (OD) (depending upon the size) aluminum extruded grooved tube made of alloy T6063 weighing 0.27kg/m. Control unit and Idler are fixed to the either ends of the tube comprising Roller Head Rail which is an aluminum extruded rail Power coated in white. Control unit and Idler are mounted on the Head rail with powder coated M.S. brackets The fabric of the blind is fitted to the tube with heavy duty adhesive tape and the Bottom rail is an aluminum extruded rail with a groove for fixing the fabric and powder coated in white. It is fixed to the bottom of the fabric and the purpose of it is, to keep the fabric in tension and straight. The fabric is fitted to the tube using plastic insert. The end caps of the tube are ABS. The size of rail shall be 21mm (OD) made of Alloy HE 9 WP weighing 0.27kg/m. The Operating chain is made of 4.5mm plastic beads molded on 2.2mm thick polyester chord. The pitch of the beads is 6mm. The chain drives the sprockets of the control unit to close and open the blind. The pitch of the chain corresponds to the sprocket in perfect match for trouble free operation in a moulded unit made from engineering grade plastic polymer with steel spring support.The fabric shall be finished on the sides with edge tape duly welded for waviness control. The fabric shall be attached to the roller tube with high quality self adhesive tape. Average width of blinds shall be 2000mm and fall of 2700mm with manual operation. Operational action shall be smooth and upto the satisfaction of the Architects.

402

-

-

... More
Rebaring : Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 8mm and depth 120mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.

50

-

-

... More
Supply installation testing and commissioning of AV over IP JPEG 2K Decoder with 1 X HDMI Out, 1 X LAN, 1 X RS232 Out , featured with videowall function with mounting accessories. as per technical specification etc. as required.

4

-

-

... More
Providing material and labour for laying 8 to 10mm thick full body vitrified tile of size upto 600mm of any shade, any finish (glossy, matt, satin or anti skid finsh) of approved make in flooring and Skirting laid over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) and fixed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including provision of groove, grouting of joints, finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Grouting shall be paid in relevant tender item. Sample and mockup shall be approvd procurement of material. Actual laid area of tile shall be measured and paid.

8570

-

-

... More
01-HVAC WORKS Sec.1.0 Machinery Supply, installation, testing & commissioning of screw type water cooled water chilling machines each having actual capacity of 170 TR (2 Working + 1 stand by) at chilled water inlet / outlet temperature of 12 °C / 7 °C having evaporator fouling factor of 0.0005 Hr - Sq. Ft. - °F / BTU FPS unit having a pressure drop of max. 5 m, with chilled water circulation rate of 450 GPM Nominal and condenser water inlet / outlet temperature of 32 °C / 36 °C having condenser fouling factor of 0.001 Hr - Sq. Ft. - °F / BTU FPS unit having a pressure drop of max. 5 m, with circulation rate of 700 GPM Nominal, With ASME pressure vessel code standards, suitable for operation on refrigerant R-134a / 407C, IPLV shall not exceed by 0.40 and complying the test standard of ARI 550 / 590 - 1998 standarad complete as per following specifications. Along with 6 Lots of Victualic Joints & Rubber Expansion Joints etc. as required to complete the job. ARI Cerified selection printout to be submitted along the technical bid. Single compressor type screw chiller Shall be semi hermetic / fully hermetic, with single circuit complete with automatic capacity control, with VFD, safety switches, speed increasing gears forced feed lubrication system etc, as per specifications. Complete job as per technical specifications etc. as required.

3

-

-

... More
Construction of Granular Sub Base (GSB) by providing coarse graded material of any grade, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, including all material, labour, machinery with all leads and lifts etc. complete as per MORTH specification and as directed by Engineer in charge.

100

-

-

... More
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 mt. Between supporting floor two ceiling including temporary brick or stone pillars for supporting as required. (I) Height more than 4.0 mt & upto 13.50 mt.

257

-

-

... More
Providing material and labour for fixing of Hollow metal fire rated doors of approved make and shade as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI against Test Schedule Ref No FR/0490 or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single & double leaf doors and Hardware should pass European certificate "CE" of conformity / UL with required fire ratings. Any deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer subject to architect’s approval and should be ISO Certified company. Providing material and labour for fixing Fire rated Door frame shall be double rebate profile of size 143 x 57 mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and SS 304 anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening. Frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test as per the directions of Engineer - in- charge. Rate shall be inclusive of anchore fastner and rubber silencer for all floor all level but excluding of SS ball bearing hinges).

53

-

-

... More
Providing material and labour for fixing G.I. barbed wire Fencing on existing MS post provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs etc for all height all level as directed by Enginer in charge. (cost of MS posts to be paid for separately) Payment to be made per metre cost of total length of barbed wire used.

500

-

-

... More
Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. d) For 40mm dia pipes - 25mm x 42mm Nitrile Rubber Plain Tubing

16

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-A FIRST FLOOR HVAC PANEL As per Single line diagram

1

-

-

... More
Tree pit cover Providing material and labour for fixing tree pit cover around the tree pit, factory made exposed /fare finish precast Tree pit cover block of two halve in FRC concrete of size - 0.90Mt x 0.90Mt x 0.065mt including transporting, fixing etc. complete as directed by Engineer in charge. The rate shall also include for erecting and fixing the pieces in position as shown in the drawing with necessary equipments without ant demage. (Sample to be approved)

100

-

-

... More
Providing and fixing C.P. brass shower rose with 15mm or 20mm inlet.(A) 100mm dia. Each

77

-

-

... More
SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 6 Sq.mm x 4C CU. Cable

264

-

-

... More
Caution Board : SITC of Caution boards of size 150 x 150 mm. to be supplied & fixed on the D.B.

70

-

-

... More
Supplying and erecting, testing and commissioning of 21W 4' Feet LED Recessed Mounted indoor Channel Linear Lights Fittings with diffuser-Make Philips make Channel RC780B LED 26S-6500PSU W6L120ODSI or equivalent as per apporved make list.

53

-

-

... More
Active Components- Data & Voice Networking TYPE-1 Supplying, installtion, testing and commissioning of Layer 3 features switch: 16 # port 10G SFP+ With redudant power supply & standard mouting hardware & accessories. Core Switch for Server room, as per technical specification etc. as required.

2

-

-

... More
Sec.6.0 iBMS System Supplying, installation, testing and commissioning of Intel Core I7 Processor with EISA bus and with 3GHz minimum clock speed, minimum of 8 GB RAM , 512 KB cache, Minimum of 1TB storage, optical Mouse, 104 keys key board, with 10/100 Mbps Ethernet card (Min. of 3 slots) & internal modem. Server shall be RAID 5 configured. The system shall be provided with 21" TFT monitor for viewing GUI application. The back up server takes over in case the master server fails. This will be a redundant server configuration. with 21" LED / LCD Colour Monitor. as per technical specification etc. as required.

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 125 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter sections with MERV 12 filter, MERV 16 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 6R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 3600 CFM / 8.05 TR With 6.0 kW Strip Heaters & Humidistate For O.T - 3 Second Floor

1

-

-

... More
Providing material and labour for applying of Swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure, such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge for all floor, all height all level. The product performance shall carry guaranteed for 10 years against any leakage.

697

-

-

... More
Exhaust fan outlet point with 6A 5 pin socket controlled by one 5 single way switch located at different location.

10

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Providing & fixing in position the mercury in glass industrial type thermometres.

106

-

-

... More
M.S. Above Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / gaskets / Nut bolts etc., and laying on the surface including painting with one coat of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required: 40mm dia

1165

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 1200 CFM

3

-

-

... More
Providing material and labour for filling 25 mm thick joint with elastomeric joint sealant two component, high performance polysulfide formulation conforming to BS:4254 and ASTM C 920 having weathering resistance to ultra-violet rays and shall exhibit shore A hardness of 25 and have movement accommodation factor 25% including using of compatible primer of approved standard for at all floors, any lead and lift etc complete as directed by Engineer In charge.

100

-

-

... More
Providing and fixing to wall and ceiling ISI Marked (Embossed) 80mm diameter of Medium Duty 'B' Class G.I. pipes as per IS: 1239, complete with cutting, threading, all fittings such as unions, bends, tees, etc, Teflon tape over threaded joints, Hilti anchor fasteners, G.I. threaded rods, double sided G.I. clamps, etc. including making good the wall and ceiling complete as directed by the Engineer-in-charge.

60

-

-

... More
Providing and placing in position LINEA DESK based modular workstation with System of Recta of Godrej or equivalent of size 1200mm x 600mm with knock down conctruction, made out of 25mm thick prelaminated board with pvc lipping. Work station shall be with under structure i.e. legs, wire manager etc in metal powder coated. full width framed screen between two work station shall be combination of white board & fabric magnetic. Rate shall be inclusive of Pedestal storage unit, CPU trolly and key board tray.

108

-

-

... More
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 mt. Between supporting floor two ceiling including temporary brick or stone pillars for supporting as required. (I) Height more than 4.0 mt & upto 5.0 mt.

25661

-

-

... More
Providing material and labour for laying of hollow concrete fair finish block masonry for jali work madeout from M20 grade average 200mm thick hollow block of different size to cerate a pattern as per drawing confirming to IS 2185 Part I grade A (7.0), shape of hollow part shall be round, square or rectangle. Jali wall shall be constructed in Polymer (consumption as per manufacturer's specification) added cement mortar 1:2 (1 cement : 2 coarse sand) by providing 2 no of 6 mm dia. GI bar at each layer vertically as well as horizontally. GI wire/ rod shall be anchored in adjoining surface with quick fix chemical including roughening, cleaning, fixing and finishing/ rendering in grey and white cement sand mortar 1:1 in the line and level and in pattern, provision of groove as per drawing, curing at all heights with necessary scaffolding etc complete as per the drawing and direction of Engineer in charge. Contractor shall prepare mock up for one panel with approved block and as per satisfactiobn of Architect. Note: Payment should as per actual area of jali made out of hollow block, no deduction of hollow gap of block should be considered for payment.

50

-

-

... More
Supply, Installation, Testing and Commissioning the Fire Alarm Valve for Sprinkler System with required accessories. a) 150 mm Dia

1

-

-

... More
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in superstructure above plinth level for all Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.

6055

-

-

... More
Providing material and labour for laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour/ DMP 60-90 TPH capacity using crushed aggregates of any grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction etc complete including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.

100

-

-

... More
Sec.2.0 Video Survelance/CCTV System Supply, Installation, Testing & Commissioning of Vandal reistant True Day Night Veri-Focal Dome Camera 2MP, Full HD, 1/2.8 type CMOS image sensor, 2.8 -12mm motorized focus lens, Aperture Ratio F1.8, Wide Dynamic Range - 120dB, H.265 / H.264 & MJPEG dual-stream encoding, 25/30fps@1080P (1920 ×1080), IR LEDs length minimum 20 m, Motion Detection , Tampering ,Defocus detection , Hallway view ,Micro SD Card - 128GB capacity, IP66 rated, IK 10 and as per technical Specification ,The Camera must be UL Listed. as per technical specification etc. as required.

104

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 25mm dia.

7

-

-

... More
4C X 10 SQ. MM. CU XLPE CABLE

12

-

-

... More
Providing material and labour for laying controlled cement concrete M-35 produced in batch mix machine, using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work for all elements, all floors, any heights/ depths, any lead and lift including cost of formwork, compacting, finishing, curing but excluding the cost of reinforcement etc complete as directed by engineer in charge.

25

-

-

... More
Providing and arranging in position Twin Mobile Drive Unit 2 Bay (U/C + Fittings + Drive + cover) of approximate size 1800mm(W) x 750 mm(D) x 2000 mm(H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS : 513 . Each body shall have a main unit plus add on units (1,2,3,4,5). Shelf construction shall be made from CRCA steel 0.8 mm thick IS :513. Uniformly distributed load capacity of 80 Kg. Undercarriage shall have construction in welded frame made of HR sheet 3.15 mm thick conforming to IS : 10748. Finish shall be epoxy polyester powder coat of approved color & shade with a dry film thickness of minimum 40 microns. The Movements shall be Drive Type configuration for mechanically through a PU Drive Wheel and Sprocket -Chain-Tensioner arrangement mounted rigidly onto body size. Each movable undercarriage shall be provided with 2 rollers on the shaft for driving, 2 antifriction ball bearings for rolling and 4 antifriction ball bearing for guiding between rails. Fittings shall be centralized locking arrangement (recess handle) through locking stiffener mounted onto back of single last unit. Door locking shall be having hinged doors of recessed die cast handle cum lock giving 3 way locking through a lever & shooting bolts. The label holder shall be made from 2 mm thick clear transparent acrylic sheet. Total no. of loading levels per understructure shall be 20 for SD2. Single static drive cover unit shall contains all required arrangement i.e. handle for hinge door, knob for manual operation, guide channel, End stopper, Easteners, facia, trim etc.

20

-

-

... More
Providing ,aterial and labour for Wall painting with anti microbial premium quality acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ liter of approved make and shade, with additional teflon surface protection, anti microbial formula & stain resistant, including applying additional coats wherever required to achieve even shade and colour over acrylic wall putty and one priming of approved make for all floor all height etc complete asdirected by engineer in charge.

1109

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. 150mm dia.

3

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 65mm dia.

4

-

-

... More
Supplying, installation, testing and commissioning of 19" rack mounting type fiber shelf for assembly/termination of minimum 12 cores of singlemode ofc cable for LC style components, for optical splicing and provision for storage of pigtails and splices, equipped with adaptors, adaptor plates and any other such all necessary hardware for proper dressing and management of fiber optic cable etc. as required. Any blank adaptor positions must be suitably masked for restricting dust entry etc. as per technical specification etc. as required.

2

-

-

... More
Supplying and erecting, testing and commissioning of 40W LED Recessed Mounted Circular Down Lighter -Make Crompton or equilavent (LCDN-40-CDL/WW))

286

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.3 - 2025 (25mm OD) pipe

150

-

-

... More
Supplying and erecting, testing and commissioning of 21W 4' Feet LED Surface Mounted indoor Channel Linear Lights Fittings with diffuser-Make SP780P LED 26S-6500PSU W6L120ODSI or equivalent as per apporved make list.

53

-

-

... More
Providing material and labour for fixing 190mm x 190 mm x 80 mm glass bricks of approved make and design with white CM 1:2 ( 1 white cement : 2 sand). Two numbers of 5 mm thick GI wires to be passed through PVC spacers in each joint horizontal as well as vertical by drilling holes in surrounding surface (brick or RCC) and filling the same with Hilti or equivalent chemical (rebarring). The PVC concealed spacer (with provision for passing the 2 no. GI wires in horizontal and vertical direction) shall be provided to maintain grooves/spaces for GI wire and white cement mortar at the junction of two glass bricks including curing. The sample of the glass brick shall be got approved by Architect. The glass bricks shall be fixed with placing GI wires vertically as well as horizontally after passing through the spacer and having minimum lap length of + 200 mm as per the site conditions at all the places, all heights, all level and in all shapes, etc. complete, as per drawing and as directed by Engineer-in-charge. Joints along the periphery of glass bricks shall be filled with approved make and color weather silicone sealant of DOW corning 789 or equivalent.

75

-

-

... More
Supplying and placing of Oxygen cylinder trolley mounted in castors with over all sizes (L)410mm X (W)375mm X (H)1112mm. Main frame for holding the cylinder consists of M.S ERW tube having section dia 25.4mm and thickness 1.6 mm. Locking rod for cylinder positioning consists M.S rod of dia 10mm. Base frame for giving sturdy base for the resting of cylinder consists of M.S ERW tube having section dia 25.4 X 25.4 mm and thickness 1.6mm. Castor wheel made of PU having dia 100 mm and thickness 25mm. Leg cap made of LDPE. Metal fabrication in ral white, epoxy polyester powder coating plastic parts in pantone cool grey 8c..

17

-

-

... More
SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 50 Sq.mm x 3.5C Al. Cable

10

-

-

... More
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for all floor, all level, all height (including all basement) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.

74822

-

-

... More
Providing material and labour for laying in position Ready Mixed M-20 grade concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.

50

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 150 mm dia.

30

-

-

... More
Civil work

-

-

-

... More
Providing, fixing AUTO GLOW photo luminescent Signage's as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: In case of Fire, do not use lift, use staircase: 8" x 8"

9

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 1400 cfm, external static 50 mmwg Exhaust air fan - 1750 cfm, external static 50 mmwg

1

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 125 mm dia.(32 mm thick insulation)

345

-

-

... More
Providing and fixing in position, interlocking rolling shutter of approved make, made of 18 gauge, 75mm wide cold rolled GI lath interlocked, including top cover (20 gauge), spring, axles (specially designed shaft), guide rails (10 gauge), tees, iron pulleys, ball bearings, handles, arrangement for inside and outside locking arrangement, with Mechanical Type (Gear Arrangement), holding down bolts embedded in CC 1:2:4 / anchor fastener of HILTI or equivalent including 1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint of approved make and shade over all the surfaces etc. as directed. (Measurements considered for payments shall be clear size of opening plus guide channels on both the sides for width and 450mm on top for drum height.)

50

-

-

... More
Sec.5.0 Cable TV Distribution System Providing following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge. (4) TV Co-axial Socket outlet.

14

-

-

... More
Supplying, laying , testing and commissioning of 4 Core X 1.0 Sqmm UnShielded Flexible Copper Cable (per I/O points hard wired to DDC). as per technical specification etc. as required.

2100

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. AUTO BALANCING VALVE complete with Flanges Nutbolts and Working parts 40mm dia.

1

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 250 mm dia.(32 mm thick insulation)

85

-

-

... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.

12

-

-

... More
CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 40 mm dia.

28

-

-

... More
Providing material and labour for fixing tree guard upto height of 1.8 metre fabricated from 30 x 30 x 3mm angle and 30 x 30mm weld mesh as per drawing and details. Necessary provisions for the anchoring to floor shall be made in the tree guard. Tree guard shall be painted with two coats of yellow oxide and three coats of enamel paint as per the shade approved by EIC.

100

-

-

... More
Supply installation testing and commissioning of Automation Controller with Minimum 4 bidirectional RS232, 4 IR, 4 Relays and 4 GP/IO and 1 Ethernet port to control video wall. as per technical specification etc. as required.

1

-

-

... More
SITC of intumescent based coating on cables/bunch cables & cable tray for at least 1 mtr in every 14 mtrs for horizontal runs and to entire length of vertical runs . The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. Firestop installation shall be done by manufacturer's Accredited Firestop Speciality Contractor (HAFSC) and in accordance with manufacturer's guidelines .

30

-

-

... More
Providing material and labour for fixing SS 316 grade butt hinge of average 100 x 64 x 2.5 mm - without ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge.

1016

-

-

... More
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. For 4.5 Kg Capacity

108

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B SECOND FLOOR EQUIPMENT NON UPS PANEL As per Single line diagram

1

-

-

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

55

-

-

... More
Sec.7.0 Plastering & Pointing works Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for all floor, all level, all height (including all basement) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.

23422

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 25mm

980

-

-

... More
Removing and scraping of old deteriorated plaster of any thickness fromm wall / R.C.C member including stacking of serviceable material and disposal of unserviceable from site of work with all lead and lift.

20

-

-

... More
Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm outside layer and 0.8mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan with 50 mm static, 4 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), with Mixing box, filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, belt with TEFC drive motor (Eff-1) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, supplied with factory fitted matching size 2 way ON / OFF actuator type Brass / Control valve / Cu piping with required couplings and ends flanged to fit CHW In / Out piping, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan and duly internally wired and tested. Followings are capacities. (With 5 Micron Filteration) 3.70 TR / 2350 CFM For X-Ray Room at Ground Floor

2

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 17.85 TR / 10100 CFM For Waiting & Corridor at Ground Floor

1

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20 mA electric signal and providing similar transduced feedback output to control system as required. 65mm dia.

6

-

-

... More
Supply, installation, testing and commissioning of Butterfly valve (manual) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified: 65 mm dia.

1

-

-

... More
Supply Installation Testing & Commissioning of Network Storage Management software (NSM) supporting ONVIF Profile S , PSIA, real time streaming protocol (RTSP) standards, 4K resolution, H.265 video compression codec, 3D PTZ control, and intelligence events. System proposed shall have 128 cameras per NSM with sufficient licenses to record all the cameras in this requirement. NSM shall support simultaneous recording, live monitoring, playback/search of recorded video for up to 4K resolution on all cameras, taking snapshots and viewing presets for PTZ cameras and system management. Smart Motion detection, Role-based operator privileges supporting Windows and local users, Video Archiving, Multi-stream support, Advanced security features with encryption support for communication between desktop client to NSM and secure https login for Web Client and Mobile apps . NSM Shall support scheduled backfilling of the recordings from the edge storage/SD card of cameras to the NSM using ONVIF Profile G for robust recording against temporary network failure, N+1/N+M recorder failover and failback automatically or manually to have maximum system uptime and recording continuity complete with hardware as per specification. as per technical specification etc. as required.

2

-

-

... More
Surface/ wall mounted signs Providng and fixing of Modular Signages using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. Internal graphics to be made of 3M vinyl printed with Hp latex 3rd Gen Eco friendly non toxic inks with UV lamination and 2 year print warranty. Sign panel shall be finished with anti-reflex cover 1mm thick with one side Matt and other side Glossy finish. Polypropylene (PP) End caps which can be fixed to the extrusion with the help of screws. Panels shall be clicked on to the end caps. Aluminium framing shall be fixed on surface with SS 304 screw and signage pabnel shall be laid on aluminium framing as per manufacturer's specification. Rate shall be inclusive of total modular signage system for all level, all height etc complete as directed by engineer in charge. Sampe shall be approved before execution and mockup shall be done with approved sample for 2 to 3 number of signage.

73

-

-

... More
Providing and fixing precoated galvanised steel sheet roofing plain Ridges (500 - 600mm) having 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :

232

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 7700 CFM / 15.84 TR For Pre Operation / Post Operation Room at Second Floor

1

-

-

... More
“Providing & erecting approved make Access control Module (ACM) having following features (A) Comprehensive Access Control Management (B) For 500 Users [AS PER COSEC GE PLATFORM users] (C) Time, User and Zone Based Access Control (D) Access Zones, Access Modes and Access Levels (E) Advanced Access Control Feature like 2-person rule, First in user rule, Antipass Back, Guard Tour, Duress Detection and more (F) Various Reports Generation

1

-

-

... More
08.00 ELEVATOR ELEVATOR FOR BUILDING - G + 2 Supplying, Erecting, Testing & Commissioning the passenger / stretcher lift having following main features: 15/16 passengers . G + 2 floor with Rated Speed of 1.5 m/sec - 1.75 m/sec with micro proce/PLC control and ACVVVF. drive, Duplex Control, Machine Room Less (MRL) - PREMIUM CATEGEROY Make : OTIS, Mitshubishi & Schindler Only (Joint Venture will not be allowed) [1] GEAR LESS LIFT DRIVE comprising of High Starting torque Lift duty 3 phase 440 V A. C. Permanent magnetic synchronous motor of proper rating with high efficiency shall be used. [2] Micro processor based / PLC, ACVVF, vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full collective selective operation hall call demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and phase reversal relay and safety controls. [3] Car with M S platform with bracings of adequate size and to sustain the impact load cabin + passenger with safety factor of fire for steel and side panels of Stainless steel of sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED ceiling lights. Car flooring shall be of anti skid PVC/Granite with choice of colour of engineer in charge. Car doors shall be of stainless steel grade 304, hairline finish with centre opening / telescopic automatic doors. Car panel will also be S.S. 304 finished with emergency stop device, mechanical door safety device, facility of auto/ attended mode. All car panel buttons and all floor switches must be with brail language as per lift act. S.S. Hand rail at 900 mm height for all three side. Door must be clear 900 mm centre openable. [4] All landing doors shall be fully automatic centre opening/ telescopic opening made of hairline finish steel grade of 304 with key holes and infrared curtains with Unlocking facility from outside. [5] Appropriate battery operated emergency light in the car along with alarm switch shall be provided. [6] Digital scrolling indicator system for up-down arrow along with floor position indicator shall be provided inside the car and at all floors. [7] Full height infra red curtain with multiple criss / crossing light beams shall be provided. [8] Automatic Rescue Device (ARD) shall be provided accordingly of passenger capacity. [9] Audio visual indication in the lift car showing over loading shall be provided such that doors kept open till excess load is removed. [10] Spring buffers/PU Buffers shall be provided. [11] Car fan with automatic sleep timer shall be provided. [12] Voice annunciater with suitable music shall be provided in lift car. [13] Self diagnostics system for operational and safety parameters shall be provided in control panel. [14] Mechanical over speed governor, door key holes in the floor doors, fireman switch shall be provided. [15] Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the Contractor, along with the other steel structure works, foundations for the machine etc… [16] In the hoist way fascia plate shall be provided without any extra cost, where ever required as / if directed by engineer in charge. [17] Permanent wiring in lift machine room and lift well with proper numbers of light points, with fixtures, exhaust fan and plug points shall be provided by the agency. Power supply of 3 phase 440 V shall be made available by department in lift machine room. [18] Any civil/ electrical works for additional and alteration in lift shaft and machine room related to erection of lift shall be made by contractor without any extra cost. [19] Agency has to provide all working drawings and documents and liaison services for obtaining all necessary permission from lift inspector and other authorities. [20] As per statutory requirement of Got. Of Gujarat lift & escalator act 2000, contractor has to provide 1. Car top safety barricade 2. Push & talk communication system. 3. Fireman's switch operation at Ground Floor

2

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 6600 CFM / 40mm Static Pressure for Autoclave & ETO Plasma Area

1

-

-

... More
Providing material and labour for laying 8 to 10 mm thick Kota stone slabs in upto 100mm high skirting, (flush with plaster) laid on average 10 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including providing 10mm wide grove between skirting and plaster, rubbing and polishing complete as directed by Engineer In charge. Sample shall be approved before execution. Kota stone shall be in uniform shade of reuired size. Sample and mockup shall be approvd procurement of material. Shade of skirting must be match with flooring stone.

3260

-

-

... More
Providing, Making and fixing SS 304 Emboss LOGO with back lited by LEDs/ SMD lightings behind the logo of size as per drawing for signage in English/Gujarati and the font style as approved sample or as per design and drawings. SS section shall be curved/ bend in shape of letter and same shape CNC cut letter. It shall be fixed on the wall with chemical anchor fastener at any level any height. All Edges and corners shall be smooth. Duco paint of approved make, shade in required coat with necessary primer and putty shall be applied on external surface of letter. Rate shall be paid in sqm. The rate shall be inclusive of scaffolding, drilling, fasteners, adhesive material etc complete for all heights as directed by engineer in charge. The rate shall also include cost of scaffolding, drilling, fabrication, finishing, adhesive material, sealant etc at all height and all lead. The contractor should submit the drawings based on concept design and do the sampling and get it approval before execution.

5

-

-

... More
4C X 16 SQ. MM. CU XLPE CABLE

2

-

-

... More
SS water trough Providing material and labour for, Fabricating and fixing SS 316 grade water trough of size 300mm x 450mm with 300mm high SS sheet cladding (dedo) made out of 1.2mm thick sheet and required size of angle, flat etc in satin/ brush finish including supporting fittings made out of SS 316 grade solid rods, flats, anges, compatible SS anchor fastener (mechanical or chemical) as per manufacturer's specifications, SS supporting arrangement, latth work, argon arc welding bending and bends as per the detail drawing with best (high) quality finish & as per the a sample approved by Architect and as directed by engineer-in-charge. Rate shall be inclusive of all material, labour and wastage for all floor, all height, all level. Water trough shall be measured in Rmt. Installed length shall be measered. Contractor shall prepare shop drawing based on concept drawing ant get approved before execution.

30

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B TERRACE HRU PANEL - OUTDOOR TYPE As per Single line diagram

1

-

-

... More
Rebaring : Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 16mm and depth 240mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.

50

-

-

... More
Providing and fixing cable stain wire for hanging the canopy as per drawing and directed by engineer inn charge.

80

-

-

... More
Supply, Installation, Testing & Commissioning of True Day Night Bullet Camera 2MP, Full HD, 1/2.8 type CMOS image sensor, Autoiris Varifocal lens 2.8 - 12mm motorized focus lens , Aperture Ratio F1.4, Wide Dynamic Range - 120dB, H.265 / H.264 & MJPEG dual-stream encoding, 25/30fps@1080P (1920 ×1080), IR LEDs length minimum 30 m, Motion Detection , Tampering ,Defocus detection , Hallway View, Micro SD Card - 128GB capacity, IP66 rated, IK 10 as per technical specification The Camera must be UL Listed, as per technical specification etc. as required.

21

-

-

... More
Metal False Ceiling: Providing & Fixing true horizontal level suspended ceiling comprising of GI Clip-in with double pip self-leveling consisting of 600x600mm clip in tiles of galvanized steel in 0.5 mm thickness with bevel edge in pre-coated Global white color with Light Reflectance 75% and fire performance of Class 0/Class 1 as per BS 476 Part 6 & 7 standards. Warranty Certificate of 10 Years and Test Reports for Fire rating shall be provided by Vendor. Installation: To comprise 3000mm long ‘C’ channels spaced at 1200mm centers securely fixed to the structural soffit using 6mm dia threaded rod connecting C- channel hanger at 1200mm C/C and anchor fastener. The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm Main carriers (spring tee bars) shall be spaced at 600mm centers in a direction perpendicular to the C-channels and secured at every intersection with C channel using a hanger. Use connector to splice two pieces of main carriers. Tiles should be clipped in between two carriers (spring tee bars) from below. Perimeter trims to be of wall angles of size 3000x19x32mm in white color secured to walls at 450mm maximum centers. Installation to be carried out by trained Installation team and as per recommended procedure of approved manufacturer. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, scafolding, making grooves between wall & board or as per drawing etc complete for all level, all height, all floor amd as directed by Engineer in charge. Only plan area shall be considered for payment.

2071

-

-

... More
Providing material and labour for fixing both side average 18mm thick mirror polished Granite stone slab as per sample approved by Engineer in charge with edges rounded and mirror polished, of required size fixed as urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement mortar 1:2 (1 cement : 2 coarse sand) as per drawing and as per direction of Engineer-in-charge. All expose edges shall be champhered and mirror polished. Rate shall be inclusive of chasing, cutting, edge champhering, edge polishing, curing, finishing, maintaining upto handling ovre the project etc complete for all floors all level etc complete as directed by Engineer Incharge.

44

-

-

... More
ELW 16.00 Earthing Supplying, installing, testing & commissioning of Maintenance Free Chemical Earthing System consisting of (A) Copper Bonded Earth Rod of 3 Mtr x 5/8" size using earth enhancing compound of 25 Kg & termination clamp. Complete in all respect with all reuqired accessories.

54

-

-

... More
TYPE-5 Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 48 # 10/100/1000Tx ports, minimum 2 SFP+ ports as per technical specification etc. as required.

4

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. 125mm dia.

3

-

-

... More
SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 35 Sq.mm x 3.5C Al. Cable

34

-

-

... More
Supplying mterial and labour for laying of following size DWC HDPE pipe of 90mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge.

100

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for DGs (2 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.

1

-

-

... More
Supply, installation, testing & commissioning of UPVC heavy duty pipes with required supports for Fresh air / Exhaust air complete with interconnection, flanges, elbows, tees, nuts etc. as per detail specifications 100mm Dia.

5

-

-

... More
Supply, testing and Layingand commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 150 Sq.mm x 3.5C Al. Cable

216

-

-

... More
Supplying, installtion, testing and commissioning of Server(s) required for NSM & NVMMS - Industry standard Intel based platform, rack mounted, redundancy architecture for critical hardware components, licensed Microsoft Server operating system and requisite user licenses, licensed application suites, 2 x Quad Core Intel® Xeon latest processors or better, 8 GB of RAM, 2 x 1.2 TB of SAS HDDs, minimum 2 additional hard disk drive bays for expansion, 1,280 x 1,024 Display/ video resolution, 2 X 10/100/1000 ethernet network interface card, Video memory 2GB above, RAID support built-in, DirectX 8.1 above and pre-installed DVD-R/W Drive and Appropriate Licensed Operating Systems as per NSM & NVMMS Requirement. as per technical specification etc. as required.

3

-

-

... More
Providing and fixing standard fireman Axe with heavy duty insulated rubber handle as per IS: 926 with clamps.

24

-

-

... More
Supply, Installation, Testing and Commissioning of Electric driven pressurization pump suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal Type, single stage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 80m.head conforming to IS standards. b) Squirrel cage induction motor with suitable HP with synchronous speed 3000 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. c) Common Base plat for Pump and motor and coupling, coupling guard, vribration pad, cables and other accessories as required for complete installation of pump set.

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 1650 cfm, external static 50 mmwg Exhaust air fan - 1750 cfm, external static 50 mmwg

1

-

-

... More
Supply, Installation, Testing and Commissioning of Communication/EPABX/ Gateway Systems .The system should be based on Server - Gateway Architecture with redundancy of Server. The connection from Server to Gateway shall be on IP and/or E1 with auto switch over, EPABX shall work with the servers in Active- Active mode which means if Primary Server fails the secondary server takes over and with same class of service and programming (As per Technical Specification) Configuration for EPABX and Gateway: - 02 PRI Card - 16 Trunks/Co Lines - 8 Digital Card - 4 Ports Inbuilt GSM Card - 4 Ports Inbuit CNR card - 50 IP Extensions - 5 SIP Trunking - 192 Analog extensions; Expandable Upto 512 Ports - 25A/48V DC Float cum boost charge with 4 hour back-up

1

-

-

... More
Providing and fixing full thread G.I. Tank Nipple (medium duty) as per IS: 1239, including drilling holes in the tanks at required levels, inserting the coupling in place, sealing the hole with silicon sealant, attaching the hex nuts on either side of the coupling as directed and approved by the Engineer-in-charge. (B) 40mm diameter

10

-

-

... More
Supply, Installation, Testing and Commissioning of Bedside Module with Call/ Cancel Button, The module should have membrane key pad with Call button (red) and Cancel button (Green) with Nurse symbol on Call button, 1xRJ45 connection for Patient Handset , 1 DIN socket and 2xRJ 45 connection for DATA BUS. Module must have antimicrobial coating on the surface and confirms to VDE 0834.

10

-

-

... More
Supply, installation, balancing and commissioning of Factory fabricated Aluminium ducts as per “SMACNA” Standards specifications for MRI Room - Supply, Fabrication, installation and testing of Ractangular sheet metal ducts in accordance with the approved shop drawings and as required by the specifications. Thickness 0.63 mm sheet

180

-

-

... More
Supplying mterial and labour for laying of following size DWC HDPE pipe of 120mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge.

100

-

-

... More
Sec.12.0 Roofing works Providing material and labour for fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per BS 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC for the best thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture of size 595 x 595 x 15 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size 24x28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200x600mm and secondary cross ’T’ to be interlocked at middle of the 1200X600mm panel to form grid of size 600x600mm resting on periphery walls/ partitions on a perimeter wall with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weight calcium silicate ceiling tiles in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, as per specifications, drawings and as directed by engineer-in-charge.

50

-

-

... More
Providing and Fixing 15 mm dia. CP brass two way bib cock with wall flange and ceramic disc cartridge complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia.

28

-

-

... More
32 mm Dia.

250

-

-

... More
Supply, installation, testing and commissioning of C.I. Gate valve (PN 1.6) as per IS:14846 complete as required: 65 mm dia.

1

-

-

... More
Providing and fixing UPVC SWR WC Connector 130 x 110 mm dia. Socket type of approved make, fixed to outlet gaskets with UPVC Lubricant or Solvent Cement, all complete as per directions of the Engineer-in-charge. Make: Astral; Model No. F172005909 or Equivalent.

206

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-D LIGHTING+SMALL POWER PANEL As per Single line diagram

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 3100 CFM / 6.26 TR For Sterile Store at Second Floor

1

-

-

... More
Supply, Installation, Testing, Commissioning of Immersion Temperature Sensor,IP 65 rated thermister type Range of temp -10 to 110) with Thermowell

10

-

-

... More
Providing material and labour for fixing in position PVC pipe sleeves of 50mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleeve shall be removed before water proofing or grouting (at rain water down take location).

100

-

-

... More
SS letter sign: Providing, Making and fixing 300mm high SS 304 letter with back lited by LEDs/ SMD lightings behind the text made of 1-1/4" SS 304 channel (1mm thick) for signage in Gujarati, Hindi and English languages and the font style as approved sample or as per design and drawings. It shall be made from ISI Brushed S.S. 304 using Water jet / CNC cutting machine. It shall be fixed on the wall with chemical anchor fastener at any level any height. All Edges and corners shall be smoothened. Width of the letter shall as per the proportion of the word for depth 1". Stainless Steel Patti shall be argon welded. Duco paint of approved make, shade in required coat with necessary primer and putty shall be applied on external surface of letter. It shall be paid in as per alphabet no. In Gujarati/ Hindi language one letter shall considered with its contents (i.e. Kano, Matra etc.) i.e. 'chhi' letter in Guajarati shall be considered as one letter. Height of letters may vary + 3" shall be included in quoted rate. The rate shall be inclusive of scaffolding, drilling, adhesive material etc. complete for all heights.

60

-

-

... More
Providing material and labour for fixing average 18mm thick mirror polish Granite of uniform size and colour for treads and risers of stair, sill, jams of window, coping etc size 1200mm to 2500 mm long, of approved shade, including necessary machine - cut edges (uniform thickness) rounded edges, as per design in required sizes and shapes over 20 mm (average) thick bedding of cement mortar 1:6 (1 cement: 6 coarse sand) laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as directed for at least 15 days or up to the satisfaction of the EIC etc complete for all floors any heights, any lead and lift as per approved sample by Architect, drawings and instruction of EIC. The rate includes machine cut edges of uniform thickness, champhering and mirror polishing of edges and maintaing upto hand over the project.

1358

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Breaker's Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.

1

-

-

... More
Providing, laying and jointing in true line and level 110 mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.

455

-

-

... More
Providing and fixing vinyl flooring of 2mm thick 100% recycled PVC flexible homogeneous and monolayer in construction of weight minimum 2600 g/m2 and should be manufactured by calendering and pressing process of size 2mt x 20mt in approved pattern, to ensure a dense, smooth surface and non-directional design, color dyed as a raw mixture to ensure even color throughout the thickness and its surface should be densely compacted for improving wear and ease of maintenance with Anti-bacterial and Fungicidal properties. The flooring shall incorporate a specially formulated Polyurethane reinforcement (PUR+) Surface Treatment having wear resistance of ≤ 4.0mm3 as per EN 660.2 and Wear Group T as per EN-649 and should have a residual indentation of −0.03mm confirming to EN-433. The laid flooring shall confirm the fire rating B1 class as per EN 13501-1. It should have low VOC contain as TVOC after 28 days 10 µg/m3 as per ISO 16000-6. The floor finish should terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm. The joints in the flooring should be sealed by using a PVC welding bar of matching colour to be supplied by the manufacturer, using a hot air gun for fusion of welding bar with flooring. The laid flooring shall confirm fire rating Bfl-s1 class as per EN 13501-1. The vinyl sheet shall be laid on existing leveled surface and fixed with water based adhesive of approved make as per manufacturer’s specification etc complete as per direction and the entire satisfaction of Engineer-in-charge. The rate shall include cost of surface preparation, all materials, wastages and labour charges for working at all levels, leads and heights.

55

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20 mA electric signal and providing similar transduced feedback output to control system as required. 150mm dia.

3

-

-

... More
Providing material and labour for fixing Natural fiber composite wood section of Tipwood or equivalent for ceiling work as per design. Ceiling board shall be made of average 7mm thick Natural fiber composite wood plank/ board. Board shall be fixed with existing framing with SS 316 grade screw and fastner as per drawing for all floor, all height, all level etc complete as directed by engineer in charge.

57

-

-

... More
Providing and fixing powder coated single point lock with mortise handle (without lock) of approved make with heavy gear mechanism of required capacity including all required accessories like handle, fork, connector, extensior, polyamide, locking point, corner transmission and striker etc as per approved manufacturer recomendatation for aluminium casement door and window (top hung or side hung) with necessary screws etc complete as directed by engineer in charge.

50

-

-

... More
Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm outside layer and 0.8mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan with 50 mm static, 4 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), with Mixing box, filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, belt with TEFC drive motor (Eff-1) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, supplied with factory fitted matching size 2 way ON / OFF actuator type Brass / Control valve / Cu piping with required couplings and ends flanged to fit CHW In / Out piping, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan and duly internally wired and tested. Followings are capacities. (With 5 Micron Filteration) 4.85 TR / 2400 CFM For Recovery Room at Ground Floor

1

-

-

... More
Providing material and labour for fixing in position PVC pipe sleeves of 110mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location).

50

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

23.5

-

-

... More
Providing material and labour for laying Plain cement concrete M15 in Foundation and Plinth including cost of formwork, compacting, finishing, curing etc complete for all level, all height/ depth as directed by engineer in charge.

1543

-

-

... More
Networking Enclosures & Accessories Supplying, installtion, testing and commissioning of ruggedized, IP55 rated outdoor Pole/Wall mountable 9U to 15U enclosure as per site requirement for housing power supplies, fiber LIUs, and networking switch, with suitable provisions for DIN rails, cable management as per technical specification etc. as per technical specification etc. as required.

1

-

-

... More
6 A x 5 pin 250 Volt universal switched socket outlet point at convenient location.

223

-

-

... More
Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. as per technical specification etc. as required.

1

-

-

... More
Supplying, installation, testing and commissioning of Network storage required with a capacity to store the content for 165 cameras for 24Hrs x 30 days at 25fps and 1080p (Minimum 110TB from day 1). It should be scalable (should have sufficient expansion bays for HDDs) for at least additional 50 cameras. Vendor shall submit bandwidth and storage calculator for the proposed camera models as per technical specification etc. as required.

1

-

-

... More
Supply, Installation, Testing and commissioning of Flow Switch with fittings, Flanges, nut-bolts, washers etc. as per requirement.

24

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 3450 CFM / 40mm Static Pressure for Toilet

2

-

-

... More
Providing material and labour for fixing Fire rated Door shutter shall be 46mm thick fully flush double skin door with or without vision lite. Door shutter shall be manufactured from 1.2mm (18guage) minimum thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a beading and screws from inside. EPDM open cell sponge seal and bottom seal shall be provided at periphery and bottom of shutter as per manufacturer's specificatipon. Door shutter shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test as per the directions of Engineer - in- charge. Rate shall be inclusive of all type seal for all floor all level but excluding of vision panel and all type of hardware.

22

-

-

... More
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 128 MB RAM & 64 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Air Handling Unit - as per IO Summary and as per technical specification etc. as required.

1

-

-

... More
Sec.10.0 Structural steel works Providing material and labour for, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats, Bars , Angles, MS Sheet, Girder, Beam, cattle trap, deep threaded MS bolts, threaded J bolts, insert plate, support plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, rungs, false ceiling frame work, Roof canopy, fencing posts, M.S. Screen & fencing jali frame work etc. including straightening, cutting, bending, bolting and welding the members all as per approved shop drawings and as per detailed specifications (for materials & workmanship) including necessary scaffolding/ staging etc. complete and comprising of Profile Cutting, Smooth grinding/ machining of edges/ faces/ all welding joints; Necessary welding; Machine drilling of holes for joining/ anchoring; dry sanding, degreasing (wet cleaning) & preparation of rustfree surface manually or mechanically, metal putty to make the surface even and smooth, 1 coat of epoxy primer and 2 coat of PU paint of approved make shade of paint over all the surfaces of the steel sections. The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and get approved before execution by engineer in charge. (Standard measurements will be paid for as actual cut length used at site)

105461

-

-

... More
Providing & Fixing heavy quality SS 304 heavy pivot top & bottom (pair) of approved make with SS screws ect complete as directed by engineer in charge.

10

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the Engineer-in-charge. Concealed Work, including cutting chases and making good the wall etc. - 18.2.2 - 1620 (20mm OD) pipe

125

-

-

... More
You are here/ map signage Providng and fixing of Modular Map Signages using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. For Map, plotter cut vinyl letters to pasted and for sliding profile print to be made of 3M vinyl printed with Hp latex 3rd Gen Eco friendly non toxic inks with UV lamination and 2 year print warranty. Sign panel shall be finished with anti-reflex cover 1mm thick with one side Matt and other side Glossy finish. Polypropylene (PP) End caps which can be fixed to the extrusion with the help of screws. Panels shall be clicked on to the end caps. Aluminium framing shall be fixed on surface with SS 304 screw and signage pabnel shall be laid on aluminium framing as per manufacturer's specification. Rate shall be inclusive of total modular signage system for all level, all height etc complete as directed by engineer in charge. Sampe shall be approved before execution and mockup shall be done with approved sample for 2 to 3 number of signage. (Measurement : Actual area for directory signage shall be considered for payment.)

24

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire Damper

15

-

-

... More
(d) 4C X 6 SQ. MM. CU XLPE CABLE

150

-

-

... More
Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet

700

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B UPS POWER INCOMING PANEL As per Single line diagram

1

-

-

... More
Lawn Plantation : 1) Supplying material and labour for filling with good quality garden soil obtained from outside, including watering, ramming well, consolidating, compacting and dressing etc. complete, as directed. Dressing and leveling the area by spreading 2"-3" of good quality soil & manual compaction as required and as approved by EIC. 2) Supply and spreading of FYM (2.50 Cum in 100 Sqm area) shall be done in proper slope as per mention in drawing including watering and fine dressing. Termite treatment to be done before laying of FYM. 3) Supplying and planting of the specified lawn on above described surface. Plantation of lawn at distance 8cm c/c. When the grass is approximately 3 cm high, it shell be rolled with a light wooden roller and when it has grown up to 5 to 8 cms above the ground, weeds must be removed and after that lawn shall be cut to the appropriate height using the lawn cutter for minimum 3 to 4 times. Weeds shall be removed regularly and periodic top dressing of FYM shall be done during the maintenance period (Bill shall be placed after completion of maintenance period.) Work shall be done in the pattern as shown in the drawing or as directed and approved by Engineer in charge. Rate shall be inclusive of surface preparation for lawn planting, Termite Treatment, Plantation, Maintenance, Watering till the end of Maintenance Period as per the instruction of EIC. Garden soil filling with FYM shall be paid in relevant tender item.

100

-

-

... More
Providing and arranging in position Single Last Drive Unit 2 Bay (U/C + Fittings +Drive + Cover) for OPTIMIZER of Godrej or equivalent having approximate dimensions 1800mm(W) x 380mm(D) x 2000 mm(H ). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS : 513 . Each body shall have a main unit plus add on units (1,2,3,4,5). Shelf construction shall be made from CRCA steel 0.8 mm thick IS :513. Uniformly distributed load capacity of 80 Kg. Undercarriage shall have construction in welded frame made of HR sheet 3.15 mm thick conforming to IS : 10748. Finish shall be epoxy polyester powder coat of approved color & shade with a dry film thickness of minimum 40 microns. The Movements shall be Drive Type configuration for mechanically through a PU Drive Wheel and Sprocket -Chain-Tensioner arrangement mounted rigidly onto body size. Each movable undercarriage shall be provided with 2 rollers on the shaft for driving, 2 antifriction ball bearings for rolling and 4 antifriction ball bearing for guiding between rails. Fittings shall be centralized locking arrangement (recess handle) through locking stiffener mounted onto back of single last unit. Door locking shall be having hinged doors of recessed die cast handle cum lock giving 3 way locking through a lever & shooting bolts. The label holder shall be made from 2 mm thick clear transparent acrylic sheet. Total no. of loading levels per understructure shall be 10 for SD2. Single static drive cover unit shall contains all required arrangement i.e. handle for hinge door, knob for manual operation, guide channel, End stopper, Easteners, facia, trim etc.

12

-

-

... More
SITC of 250 A FP MCCB with Sheet steel metal enclouser

2

-

-

... More
Providing and Fixing 15 mm dia. Wall mounted type CP brass pressmatic bib cock with Auto Closing System with Built-in Control Cock With Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia.

72

-

-

... More
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 128 MB RAM & 64 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Chiller Plant Room - as per IO Summary and as per technical specification etc. as required.

1

-

-

... More
Demolition of Brick Work/AAC block work with plastered surface/ wall dedo including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.

20

-

-

... More
Supplying well grown shrub plants and ground cover plants of average height 3' to 4' and planting in planter box or prepared ground area (prepared and filled with garden soil filling). Plants should be disease free and fungus free in 8"x 10" polythene bag. Plastic bags or pots should be removed carefully and soil around the roots should not be dropped or disturbed much. Distance between two shrub shall be as per drawing. Bill shall be placed after completion of maintenance period but not before stabilizing the shrubs. Mortality rates to be inclusive. Work shall be as directed and approved by Eingeer in charge. The ground coverage should be dense and uniform throughout the planting area. Excavation and soil filling shall be paid in relevant tender item.

100

-

-

... More
Providing material and labour for Excavation of foundation from 3.0 mt to 5.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in the campus for all lead, all lift/ depth and back filling foundations, the trenches, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by engineer in charge. - Any type of soil or rock not requiring Blasting.

11667

-

-

... More
Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. c) For 32mm dia pipes - 25mm x 35mm Nitrile Rubber Plain Tubing

36

-

-

... More
Sec.9.0 Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. 3rd Year after DLP

1

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 125mm dia.

3

-

-

... More
Telephone / Data Networking Cabling Supplying & erecting approved make LAN cable of following size in existing pipe as per direction. [C] CAT - 6

25640

-

-

... More
Sec.6.0 Nurse Calling System Supply, Installation, Testing and Commissioning of Nurse Calling System: Management Server: System Server used for uploading the firmware and the system configuration, for operating interfaces to foreign systems, for logging of all system events and as a central location for system configuration and remote maintenance and is an interface to all other foreign systems. The Server specification should be:-CPU: Intel Xeon Dual core 2.3 GHz, RAM: 4GB DDR2-800, 1xSATA HDD (2 TB), 2xPCI, 2x1GB LAN, Case for fitting in a 19” cabinet, Operating system: Linux (SUSE Server 10.x), Pre-installed system software as per technical specification etc. as required.

1

-

-

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

200

-

-

... More
Supply, installation, testing and commissioning 63 mm dia, 2x15 Mtrs. long RRL Hose Pipe with 63 mm dia male & female gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A - RRL) as required.

24

-

-

... More
Providing material and labour for applying Tack Coat with Cationic Bitumen Emulsion RS1 complying with IS:8887. The tack coat shall be applied by a self-propelled or towed bitumen pressure sprayer, equipped for spraying the material uniformly at the rate of 2.5Kg/Sqmt etc complete including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge. No dilution or heating at site of RS1 bitumen emulsion shall be permitted.

100

-

-

... More
Dismentalings any type of ceiling or partition walls, wooden trellies work including grid and suspension system with all elements stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.

20

-

-

... More
Supply, installation, testing & commissioning of Propeller type Exhaust Fan. - 1000 CFM

3

-

-

... More
Providing material and labour for applying Distempeing (Two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on wall and ceiling surfaces to give an even shade, over and including a priming coat with alkali resistance primer of approved brand after thoroughly brushing the surface and other foreign matter and also including preparing the surface even and sand parpered smooth etc complete for all floors, all heights, all level as directed by Engineer Incharge.

50

-

-

... More
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (a) 20mm dia nominal bore.

4

-

-

... More
Providing material and labour for fixing Natural fiber composite wood section of Tipwood or equivalent for fabricating the louver type partition as per design. Framing shall be made out of 50mm x 50mm x 6mm size box section of natural fiber composite wood with intermediate member. Louver strip shall be made out of 100mm x 6mm Natural fiber composite wood section as per drawing. Total assembly (frame + louver strip) shall be made out of Natural fiber composite wood section. Natural fiber composite wood section shall be fixed with adhesive and SS 316 screw and fastner by cutting etc complete for all floor, all height, all level and as directed by engineer in charge.

787

-

-

... More
Providing and arranging in position INSTRUMENT TROLLEY WITH BOWL & BUCKET of Godrej or equivalent. SS 304 sheet should be used at top for the placement of the instruments being used. SS 304 sheet should be at the top as well as bottom shelf for keeping the instrument being used. Horizontal bars should be welded with legs to provide protection at sides with supporting legs for sturdy structure. Castors of 125mm Dia. should be used for easy in movement. Spin section should be provided to the bowl & bucket should be provided with removable lid & a handle to lift the bucket. Overall Dimension must be 1232mm X 531mm X 915mm H.

17

-

-

... More
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 50 mm dia.

50

-

-

... More
SITC of 19/20mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/O. 2 flat 3 core flexible wire with ear thing.

367

-

-

... More
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 102 to 125mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.

50

-

-

... More
“Providing & erecting approved make Card Reader having following features. “[A] Wiegand/ RS232 Interface “(B) Power supply from COSEC Door controller or through Separate Adaptor “(C) Compatible with any COSEC Door controllers “(D) 4 LEDs (Status, Alarm, Allowed and Denied) and Buzzer “(E) Tamper Detection”

1

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.6 - 4050 (50mm OD) pipe

385

-

-

... More
(b) 3.5C X 35 SQ. MM. AL XLPE CABLE

150

-

-

... More
TYPE-2 Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 24 # 10/100/1000Tx ports, all 24 ports shall be capable of providing PoE+ as per 802.3at, minimum 2 SFP+ ports. as per technical specification etc. as required.

9

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Secondry Pump Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.

1

-

-

... More
Supply, Installation, testing and commissioning of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 300 x 100 made out of 2 mm thick perforated type

935

-

-

... More
Getting Approval/NOC of Fire protection system (Hydrant, Sprinkler etc..) from local fire authority and any other relevant statutory authority at initial and various other stages of work, including preparation of report/drawings as per fire authority.

1

-

-

... More
SITC of Outdoor Type 6/16A Socket with Switch, Suitable for outdoor appication (IP66)

15

-

-

... More
Pediatric ICU Bed Providing and arranging in position Pediatric Bed with following specification 1) Overall Approximate size: 1375 mm (L) x 760 mm (W) x 610 mm (H) 2) Bed Frame approx. dimensions: 1315 mm (L) x 710 mm (W) 3) Approximate 60 x 30 mm rectangular CRCA framework. 4) CNC Machine pressed and bent uniformly, perforated sheet top in two sections. 5) Main frame is mounted on base frame fitted with Castor Wheels of 125 mm dia., two of them with breaks. 6) Telescopic saline stand provision at four locations on bed frame. 7) Removable Powder coated head & foot bows. 8) Detachable fully length CRCA tubular drop – down railing. Overall approximate size: 1375 mm (L) x 760 mm (W) x 610 mm (H) 9) Bed Frame approx. dimensions: 1315 mm (L) x 710 mm (W) 10) Shot blasted, chemically pretreated and epoxy powder coated Finish. 11) Rexin covered PU foam Mattress in Two sections of 100 mm thickness. 12) Detachable collapsible bedside railing made up of S.S. 304. 13) Removable S.S head & foot ends with laminated panel boards.

12

-

-

... More
100 x 105 mm

20

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Supplying, fixing, testing and commissioning of Automatic Air Purge Valve at AHU chilled water outlet pipe duly insulated to the same specifications as the connected piping and adequately supported as per specifications. 20mm dia.

45

-

-

... More
Supply, Installation, Testing, Commissioning of Air Type Differential Pressure Transmitter

26

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 1700 cfm, external static 50 mmwg Exhaust air fan - 1750 cfm, external static 50 mmwg

1

-

-

... More
Sec.9.0 Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. 4th Year after DLP

1

-

-

... More
Providing and arranging in position IV POLE ADJUSTABLE HEIGHT ON BED of Godrej or equivalent. Overall size is hook arm pcd 250mm x H adj from 743 mm to 1150mm from bed frame top. SS 202 make Bottom Adaptar, Saline hook & SS 304 make Telescopic rod is made of 12mm dia. All SS item has glossy buffed finish. IV pole shall be of knocked down construction. The manufacturer should compilant with ISO 9001, 14001,13485, OHSAS 1800 and CE certification.

316

-

-

... More
4C X 6 SQ. MM. CU XLPE CABLE

6

-

-

... More
SITC of Self contained double sided exit sign for wall / ceiling / pendant cantilever mounting with 3 watt LED tube, Non maintained battery backup 2 hours duration Prolite make or approved equal in quality and design.

24

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 9.40 TR / 4750 CFM For Reception Waiting & Corridor at First Floor

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 900 CFM

3

-

-

... More
Supply, Installation, Testing and Commissioning of Floor Switch: Uplink connections: 2 x 1Gb uplink ports, RJ45 (GBIC capable, possibility for LWL) Connections downlink: 24 x 100Mb downlink ports, RJ45 as mentioned in the Tender Specification.

2

-

-

... More
Providing material and labour for laying average 25mm thick machine cut semi mirror polished Green Kota stone slab of size upto 600mm in flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift in any shape and pattern etc complete as directed by Engineer In charge. Sample shall be approved before execution. Kota stone shall be in uniform shade of reuired size. Sample and mockup shall be approved before procurement of material.

3864

-

-

... More
Providing material and labour for fixing 1 mm thick Laminate sheet of any size, any shape, any color, any texture of approved make and as per approved sample (approved by architect) on Non decorative flush door, panelling work, fixed partition, any ply surface etc with necessary nails, screws, adhesives as per drawings and as per approved sample. The rate shall be for all heights, all floors, all places etc complete as directed by engineer in charge. Actual laid area shall be measured and paid without considering any westage. Laminates and ply shall be factory pressed.

50

-

-

... More
SITC of No.8 gauge bare cu. earth wire Complete in all respect with all reuqired accessories.

304

-

-

... More
Pylon signage - 800mm x 2000 mm Providing and fixing of Totems of size 800mm x 2000 mm using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15-20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod and Qualicoat International standards. Internal structure to be made from ms section of required size with proper support in between and 3mm ACP to be slided from both sides. 3mm ACP to have 3M vinyl printed with Hp latex 3rd Gen Eco friendly non toxic inks with UV lamination and 2 year print warranty 3 mm ACP sheet with High intensity Prismatic Grade reflecitve sheeting with top hat of 2 mm Aluminium and bottom hat of MS 6 mm thick depending on size of Pylon.

3

-

-

... More
Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm outside layer and 0.8mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan with 50 mm static, 4 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), with Mixing box, filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, belt with TEFC drive motor (Eff-1) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coils, supplied with factory fitted matching size 2 way ON / OFF actuator type Brass / Control valve / Cu piping with required couplings and ends flanged to fit CHW In / Out piping, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan and duly internally wired and tested. Followings are capacities. (With 5 Micron Filteration) 2.06 TR / 1100 CFM For Lab at Second Floor

2

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / Hot Water multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built 2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with "Y" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 400 CFM

3

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.5 - 3240 (40mm OD) pipe

130

-

-

... More
Supplying, laying , testing and commissioning of 4 Core X 1.0 Sqmm Shielded Flexible Copper Cable (per I/O points hard wired to DDC). as per technical specification etc. as required.

1900

-

-

... More
MEDIUM VOLTAGE CABLE Supply, laying, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, stranded AL / Cu conductor Armoured cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building. The scope shall include: Supply of Cables. Delivery of the cables at site. Unloading at site store. Shifting of cable from site store to place of installation. Excavation in hard or soft murrem / rocky area upto required depth, supply and laying of protection bricks, supply and backfilling with fine sand, leveling the ground to match with the existing condition. Laying of cable in the excavated trenhc / prepared trench / cable tray / duct / hume pipe / channel / floor trunks when laid inside or outside the building. Connection of cable. Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. Testing of insulation and continuity of cable and submission of reports to the client's representative. To prepare submission drawing and to take approval of consultant at each stage. To prepare & submit as-built drawing and handing over document to end user. (a) 3C X 4 SQ. MM. CU XLPE CABLE

50

-

-

... More
Supplying , fabricating and installation of various sizes junction boxes made out to 14 gauge sheet with all necessary accessories & hardware etc All the necessary fabrication required will be included in the scope of contractor. Scope also includes two coat of primer and two coat of paining of each items on all the sides complete in all respect.

100

-

-

... More
Supplying, laying , testing and commissioning of 2 Core X 1.0 Sqmm Shielded Flexible Copper Cable (per I/O points hard wired to DDC). as per technical specification etc. as required.

2500

-

-

... More
Supplying and erecting, testing and commissioning of exhaust fan equivalent to crompton make Cross Air Fan 10” DIA with self opening louvers.

10

-

-

... More
Providing material and labour for fixing vision panel made out of 5mm thick clear toughen glass of any shape any size in all type/ thickness of flush doors shutter. Glass shall be fixed with teak wood lipping (Lacquer polished of approved make and shade) on both side the door of required size as shown in drawing and direction of Engineer-In-Charge. Rate shall be includes the cost of cutting door, provision of glass with both side polished lipping, making good etc complete. The actual installed area of vision panel shall be measured for payment.

50

-

-

... More
Primary chilled water pumping system : Supply, Installation, Alignment, Testing and Commissioning of End Suction Top discharge Back Pull out Centrifugal type Primary Chilled water pumps as specified. The pump shall be dynamically balanced and supplied with Flexible coupling with Guard, Corrossion resistant painted factory supplied MS baseframe with necessary vibration isolators and Rubber flexible bellows at suction and discharge nozzels; Pump shall be designed to operate for 18 MWC TDH; this TDH is assumed; Pumps shall be checked for Parallel Pumping Operation and checked for actual (vendor specific) Chiller Shell Pressure drop to arrive at actual TDH and Motor Ratings; Quoted price shall include cost of complete with electrical Starters, vibration isolation and all other associated accessories & duly insulated with insulation and finish similar to Chilled water piping Insulaiton specifications ; 450 GPM (2 working + 1 stand by) Complete job as per technical specifications etc. as required.

3

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 50 mm dia.

6

-

-

... More
Supplying and placing of Over Bed Table with Overall Sizes (L)896 mm X ( W)395 mm X (H) Adjustable from 797mm to 1085mm Description - OBT should be a height adjustable Over Bed Table.Table top Height can be adjusted with the help of operating handle which activates the gas spring to assist the table top to lift. Material Specifications Base frame should be made of ERW Round Tubes and Oval Tubes. Housing should be made of ERW cylindrical tubes Operating Handle : Handle with wider area for gripping : Smooth functioning gas spring with adjustable height and consistent motion during operation. Plain top should be membrane pressed MDF 395 mmx 896 mm and having thickness of 18mm. MDF top with membrane press should give anti scratch Property with good surface finish. Castors: High endurance anti-static,Plastic injection molded castors are provided of Ø50mm Finish Specifications – Powder coating should be Bacteriostatic and thermosetting epoxy polyester,formulated to fulfill the requirements for bacterial protection. All powder coated parts in RAL white. Plastic parts in Grey Performance Specifications – Max Safe Working Load: 20 kg UDL.

356

-

-

... More
Providing material and labour for laying Cement Mortar for additional floor bedding in Cement Mortar 1:6 (1-Cement: 6 - coarse sand) including curing etc for all floor, all level all height. Additional bedding thickness shall be as per drawing and as directed by engineer in charge.

899

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

1044

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B FIRST FLOOR HVAC PANEL As per Single line diagram

1

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. AUTO BALANCING VALVE complete with Flanges Nutbolts and Working parts 100mm dia.

6

-

-

... More
Supplying and erecting, testing and commissioning of 50W LED Recessed Mounted Square indoor Panel -Make Crompton or equilavent (LCTLRN-50-F0-CDL)

2

-

-

... More
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 50 Sq.mm x 3.5C Al. Cable

95

-

-

... More
Supply, Installation, Testing and Commissioning of Software - License for event database Software pack on the Management Center for automati-cally handling of all events in the entire communications system, e.g. calls, presences, call acknowledgements, presences etc. This indication and analysis of the data is through a browser which has password-protected access to the XML data on the server. Various filters make it easily to find and display the required information.

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 600 CFM

15

-

-

... More
Providing material and labour for laying machine cut single polished 18mm thick Jesalmer yellow stone in flooring, band etc as per design and drawing over 20 mm thick cement mortar 1:3 and pointing in joints in white cement with matching pigment, curing etc. complete. The rate should also include for polishing with different grades of emery, daily moping with water, buffing, finishing at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge.

50

-

-

... More
Chemical Anchor: Providing material and labour for fixing chemical anchor medium to heavy duty injection adhesive for Anchor fixing in Dry conditions and HILTI HIT-HY 200 + HIT-V rods of size 12mm x 150mm of HILTI or equivalent as per drawing or as instructed by EIC. The system should be made of two foils consisting of resin and Hardener foil pack. The system can be used for threaded rods HIT-V rods or equivalent rods. The installation and the setting instructions should be strictly followed as per the manufacturers recommendations. Rate shall be inclusive of injection adhesive and fastner rod of same make.

50

-

-

... More
Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), vent cowl as approved and directed by the Engineer-in-charge. For 160 mm Dia pipe

60

-

-

... More
Grille, Damper & Filter Assembly for Fresh air intake 100mm Dia.

1

-

-

... More
Providing material and labour for fixing of SS 304 grade brush finish 450mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

485

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-C LIGHTING+SMALL POWER PANEL As per Single line diagram

1

-

-

... More
Providing material and labour for fixing hydraulic rack and pinion door closer with standard arm (Silver finish) with screws to pivoted/ hinged door of approved make for specified door width with minimum one year guarantee. All adjustment screws face fixed. Rate shall be inclusive of fixing with using the template as per manufacturer’s specification & maintain in good working condition until defect liability period. The door closer shall conform to EN 1154 standard. a) with standard/ hold open arm with two independent closing valves and latching speed adjustable by arm without mounting back plate, Closing force complying with EN 1154 2 - 4 for up to 900 mm door shutter width

437

-

-

... More
Bell point controlled by Bell push switch with Buzzer / bell of approved make.

1

-

-

... More
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.69.2: Waste coupling 38mm dia of 83mm length and 77mm breadth, weighing not less than 60 gms.

41

-

-

... More
Providing material and labour for applying Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc complete for all floors, all heights, all level as directed by Engineer Incharge. Product to be

18396

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. BLOCK-B FIRST FLOOR UPS PANEL As per Single line diagram

1

-

-

... More
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 6 Sq.mm x 4c CU. Cable

4644

-

-

... More
Providing, laying and jointing in true line and level 75 diametre U.P.V.C (Type A) conforming to IS 13592 with one end plain and other end socketed with rubber ring, for drainage system pipe line in FFTG and HVAC shafts, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 80 mm diametre x 149 mm length x 145 mm height at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.

150

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Fresh Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 3600 CFM / 40mm Static Pressure for Dirty Corridor

2

-

-

... More
M.S. Above Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / gaskets / Nut bolts etc., and laying on the surface including painting with one coat of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required: 25 mm dia

2996

-

-

... More
Providing and arranging in positionadjustable ICU bed with 5 function mechanically operated, 2 seactions 100mm thick Mattress, castors of VITA of Godrej or equivalent. Bed shall be of approximate size (L)2272 mm X ( W)1048 mm X (H) Adjustable from 470mm to 750mm. 5 function mechanically operated bed viz. Hi-Lo, Trend/ Reverse trend, Back rest and Knee rest and lower knee rest. Patient load bearing capacity: 135 kgs. Head & Foot board should be made of blow molded Poly propylene with anti microbial additives. The boards should have provision to paste colour stickers made of PP material and pasted with 3M adhesive. Bed should have provision 4 iv pole holders & 2 patient lifting pole holders. Lying surface shall be made of 1mm thick CRCA sheet having 4 sections for bed profiling i.e. back adjustment, fixed pelvic section, upper and lower leg adjustment. Mattress should have 2 section 100 mm mattress and made of 40 density pu foam and placed in platform. The mattress should have high end heavy hellium cover which is water resistant, x ray permeable, fire retardant. The manufacturer should compilant with ISO 9001, 14001, OHSAS 1800, USFDA and CE certification. Bed shall be with knock down construction system and made of MS EWR tube and CRCA steel. All metal components should be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbial epoxy polyster powder coating

42

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 65 mm dia.(32 mm thick insulation)

455

-

-

... More
Providing and Fixing SS 304 Grade Satin Finish 1.8 mm Thickness Tadi of 12mm dia x 200mm including 3 nos.fixing Bracket of approved make with necessary screws, pins, bolts etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.

3

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 125mm dia.

3

-

-

... More
Providing material and labour for laying Ceramic tiles 6mm thick in skrting, risers of steps and dedo laid on plastered wall with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Sample and mockup shall be approved before procurement of material.

50

-

-

... More
MCB 's and its Accessories Supplying, Assembling, levelling, connecting testing and commissioning of following MCB / ELMCB / MCCB etc in boards as specified in 8.1, 8.2. Miniature circuit breaker single pole 1A to 32A. suitable to operate on 240V. A.C. system and having breaking capacity 10 KA to be erected in existing box. Confirming to IS 8828 / 1996 with ISI Mark.

1056

-

-

... More
Providing material and labour for designing, fabricating, installing sliding folding shutter façade system as follow- 1) Frame shall be made out of Aluminium having 50 micron polyster powder coating of approved make and shade as per drawing. 2) Natural fiber composite wood plank of size 100mm x 6mm of Tipwood or equivalent shall be fixed in aluminium frame with necessary SS 316 screws and fastner. 3) Shutter shall be fixed on Aluminium Track with necessary Corossopn resistance SS 316 hardware like pivot, hinges etc of Mantion, Enox or approved equivalent. Rate shall be inclusive of all material i.e. Aluminium framing, Natural fiber composite wood plank, Aluminium track and SS316 hardware, labor for fabrication and erecting the system for all floor, all level all height etc complete as directed by Engineer in charge. All loose sample of material shall be approved before fabricating the system. Mockup shall be caried out with approved sample for 10.0 Sqm area. Contractor shall furrnished gurntee against material and operationg system. Elevation area of facade system shall be measured for payment.

802

-

-

... More
Supply, installation, testing and commissioning of ABC type 6 kg Fire Extinguisher confirm to IS:15683, with ISI marked / TAC approved fitted with required accessories including wall suspension brackets.

108

-

-

... More
Providing material and labour for Filling in plinth with sand under floors or base of foundation including watering ramming, consolidating and dressing etc complete as directed by Engineer in charge.

641

-

-

... More
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 125 to 152mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.

50

-

-

... More
Providing material and labour for fixing 1 point panic device in Contur design, carry bar for single door for fire and smoke check doors, with steel latch, security anti thrust latch for door widths upto 1300mm, consisting of 2102F, 2105 in silver finish of approved make. As per EN 1125, CE marked etc. complete for all floor, all height as recommended by manufacturer and as directed by Engineer in Charge.

9

-

-

... More
Sec.2.0 Air Moving Equipment Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 11350 CFM / 27.70 TR For PICU, NICU, Nurse Station & Passage at Ground Floor

1

-

-

... More
Supplying, installation, testing and commissioning of IBMS Server Software suite: This Web technology based software suite shall have unlimited concurrent user login licences. The client license provided shall display actual graphics as represented in the server machine. Shall be capable of interfacing with Bacnet/IP based DDC controllers, Bacnet/IP or modbus RTU 3rd party interface. Complete with Webserver for IBMS interface on Internet / Intranet. License for minimum hard/soft I/Os to be considered as per I/O Summary. Software should have the following Key features: 1. User Defined dashboard. Any Number of dashboard can be added by user. 2. Scalar/Vector Graphics to be supported. 3. Monthly Calender Dashboard: Monitor the demand/ consumption pattern for all days in a a month in a single screen. 4. Software shall be able to communicate with bacnet/ lonworks/ modbus simultaneously. 5. Mobile Platform: IPAD/ Android Compatible. 6. Software shall be Forword & Backward Compatible with 10 Years Obselation Support from OEM. 7. Display of HTML 5 Pages fromm company intranet or Internet for full smart device compatibility - with NO Java Dependancy in the Browser. 8.Database supported by software should be either SQL/oracle/db2. Also software should support 128 bit ssl encryption. Note: All required Software with original license competent with BMS software

1

-

-

... More
Supplying mterial and labour for laying of following size DWC HDPE pipe of 200mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge.

100

-

-

... More
WATER COOLERS: Conveyance charges including loading / unloading for Water Cooler from store to site (I) Local up to 10 Km

47

-

-

... More
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (c) 32mm dia nominal bore.

30

-

-

... More
Providing material and labour for fixing Ductile iron manhole frame and cover/ grating/ chamber cover of approved make and type. Man hole cover shall be any type (hinged type, double sealed or recess type), any shape (square/ rectangle/ square frame with round cover) any grade (light duty/ medium duty/ heavy duty) of required loading capacity having double sealed system as per manufacturing standard BS EN-124, with proper lifting arrangement, black bituminous coating, including fixing in CC and finishing etc complete as directed by engineer in charge. Cover shall be as per drawing and as per approved sample. Recess manhole cover depth shall be according to pavement/ finish as per drawing.

500

-

-

... More
EXPANSION TANK 350 LTS CAPACITY Supplying, installation, testing and commissioning of Precharged Steel Closed expansion tank as per specification with replaceable heavy duty butyl rubber bladder, mounting stand with all necessary system connection & charging valve connection to facilitate on site charging. Tank to meet ASME Boiler & pressure vessel code along with all necessary valves & fittings complete as per technical specifications, drawings and requirements. - 300 Litres.

1

-

-

... More
Condenser Cooling Water Pumping System with accessories Supply, Installation, Alignment, Testing and Commissioning of End Suction & Top discharge Back Pull out Centrifugal type Condenser Cooling water pumps as specified. The pump shall be dynamically balanced and supplied with Flexible coupling with Guard, Corrossion resistant painted factory supplied MS baseframe with necessary vibration isolators and Rubber flexible bellows at suction and discharge nozzels; Centrifugal Pump with above accessories. Pumps shall be checked for Parallel Pumping Operation and checked for actual (vendor specific) Condenser Shell Pressure drop to arrive at actual TDH and Motor Ratings; Quoted price shall include cost of complete with electrical Starters, vibration isolation and all other associated accessories ; performance curves will be attached with the Bid. 680 GPM / 15 M WC (2 working + 1 stand by ) Complete job as per technical specifications etc. as required.

3

-

-

... More
Supply, installation, testing & commissioning of Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of proper insulated copper tubing up to 5 RMT suitable for (Cost includes M.S. Stand, Gas Charging & Internal Copper Wiring & Remote Control) 1.5 TR Capacity

1

-

-

... More
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Fire Alarm System (1500 Points) Soft Data Integration on Bacnet Over IP. as per technical specification etc. as required.

1

-

-

... More
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (f) 65mm dia nominal bore.

24

-

-

... More
Supply, Installation, Testing & Commissioning of Vandal Resistant PTZ Network Cameras ,IR with 350 Mtrs Viewing Distance 30 X Optical Zoom,camera with 1/1.9" sensor, 2MP, Full HD(1080p) @60fps WDR off or @15fps WDR on, H.265/H.264/MJPEG, 120dB WDR, Auto Tracking, true D/N, ,Edge Analytics - Auto Tracking, Virtual Perimeter, Entry/Exit Detection, Tampering,SD/SDHC/SDXC memory slot, 24VAC, IP66, IK10 .including all mounting accessories.The Camera must be UL Listed, as per technical specification etc. as required.

5

-

-

... More
Providing and fixing high quality FRP gratings of size 40mm x x40mm x 30mm high having the load tested as per BSEN 124, IS1726 & AASHTO M306 standards of approved make and shade. Grating shall be directely fixed on wall of RCC channel as per drawing and as directed by Engineer in charge. Actual installed area of grating shall be meaured for payment with out considering any wastage.

20

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 300 CFM

1

-

-

... More
CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 25 mm dia.

5

-

-

... More
Providing material and labour for Cutting holes of required size in brick/ block masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.

50

-

-

... More
Providing and fixing Polyethylene - Aluminum - Polyethylene (PE-AL-PE) composite pressure pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers, & connectors etc. with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. Internal Work - Exposed on wall - 18.1.4 - 2532 (32mm OD) pipe

150

-

-

... More
Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Supreme / Ashirvad. b) 25 mm nominal bore

20

-

-

... More
Providing material and labour for fixing 6mm thick Wired Glass of any size, any shape in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing with EPDM quality rubber/ silicon sealant/ structural sealant on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Architect. Actual installed quantity shall be measured and paid. Rate shall be inclusive of all type of wastage.

1334

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 125 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter sections with MERV 12 filter, MERV 16 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 6R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 4500 CFM / 10.08 TR With 6.0 kW Strip Heaters & Humidistate For O.T - 2 Second Floor

1

-

-

... More
“Supplying & erecting push button type telephone instrument having speaker phone Caller ID & hands free dialing system “(a) Single line BPL/SONY/BEETEL or equivalent make”

187

-

-

... More
Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Supreme / Ashirvad. a) 20 mm nominal bore

25

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 150mm dia.

13

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts. 40mm dia.

35

-

-

... More
Supply, Installation, Testing and Commissioning of Network Keyboard, 7" TFT touch screen, up to 256 units of DVR/Network Cameras/Speed Dome management, 1-ch HD 1080p video steam decoding, USB 2.0 interface for video backup

1

-

-

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. as per technical specification etc. as required.

27

-

-

... More
Sec.3.0 MECHANICALS Hot Water Plant: Supplying, installing, testing and commissioning of Electrically Operated Air-to-Water Heat Pump Hot Water System capable of heat output of minimum 3.64Kw @ COP OF MIN 3.6 producing Hot water up to 55°C, at ambient temperature of 12°C to 55°C. Heat pump should have an IPX4 compatible control panel, designed and built in manufacturer's factory and compliant to norms for the same and compatible to support 8 units in parallel. Inbuilt 4 Ways valve for auto defrost function. The heat pump shall have an operational noise level of less than or equal to 65 dB(A). Model should be with tube in tube type heat exchanger Comprising of helical rotary twin compressors with direct drive motor (the compressor speed shall not exceed 3000 RPM) with shell and tube type plain tube chiller as well as shell & insulated tube type integrally finned condenser, at working efficiency of minimum 80%, having heating capacity up to 60 degree centigrade, capable to withstand up to 300 ppm water hardness. The heat pump package shall include vibration mountings, copper refrigerant piping as per the latest applicable B.I.S. codes and standards, full refrigerant charge using CFC free gas, system control wiring and accessories, installed on a fabricated mild steel base frame assembled to form a compact assembly, complete with micro-processor based control panel comprising of adaptive controls, indication lights, Star-Delta starters, over-load and under-load protection, TPN isolator for termination of incoming power cable, necessary control wiring, disconnect switch, grooved (Victaulic couplings at inlet and outlet of both heat exchangers, DP switches for both heat exchangers, vibration isolation arrangements electrical panel with starter for Heat Pumps, testing of all systems post installation at Minimum Wet Bulb Temperature of 17.7 degree Celsius in January to deliver hot water at 55 degree Celsius. The scope also includes commissioning of the entire system, commissioning certificate in the name of the Engineer-in-charge, etc. complete as per manufacturing standards and to the complete satisfaction of the Engineer-in-charge. The scope includes pre-insulated S.S. storage tanks or M.S. storage tanks with ceramic lining, of capacity as mentioned below, including making inlet, outlet heavy gauge C.P. connection, temperature guages (at inlet and outlet of storage tank). The Storage Tanks duly painted with two coats of Red-Oxide and having PUF / Rockwool insulation, outer cladding of 22 guage Aluminum Sheet, control valves at inlet and outlet of Water tank, M.S. supports for the tanks with M.S. base plate, bolts and nuts for fastening the stands and support to Cement concrete blocks, testing the tanks and the entire hot water system at a constant water pressure of 5.0 Bar (50 Mtrs) each, testing of the entire system for a constant flow of hot water at 55 degree Celcius during peak winter when the Wet Bulb Temperature is 17.7 degree Celcius. Make: A O Smith. FOR BLOCKC: Total System Capacity: 200 LPH; Heat Pump HWS: 200 LPH (peak load) with 300 Ltr capacity storage tank. Heat pumps of 1.1 kW (output capacity - 3.64 KW), electrical starter panels, level sensors, temperature sensors, thermostat, temperature gauges, pressure gauge, interconnecting G.I. 'C' class pipes with nitrile rubber cladding and aluminium cladding, complete.

5

-

-

... More
Supply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 450 x 100 made out of 2 mm thick ladder type

150

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 3800 cfm, external static 50 mmwg Exhaust air fan - 5250 cfm, external static 50 mmwg

1

-

-

... More
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 128 MB RAM & 64 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Ventillation Fans - Smoke Exhuast , Evacuation Fans, as per IO Summary and as per technical specification etc. as required.

1

-

-

... More
4.00 ELV SYSTEMS Sec.1.0 Telephone and Data Networking Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed. 25 mm

24684

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 150 mm dia.(32 mm thick insulation)

35

-

-

... More
Rebaring : Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 12mm and depth 180mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.

50

-

-

... More
Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. b) For 25mm dia pipes - 19mm x 28mm Nitrile Rubber Plain Tubing

48

-

-

... More
Providing material and labour for laying approved quality average 18mm thick River wash finish Granite of required size, approved shade in floor, otta, skirting, pavement, plaza or similar in any pattern including average 20 mm thick cement mortar bedding in 1:6 laid and jointed with white cement and matching pigment including rubbing, curing, finishing, cleaning etc complete as directed by EIC. Sample shall be approved before execution. Laying patern shall be as per drawing and instruction of EIC for all floors/ all levels/ all heights and all shapes. (Only finished work will be measured.)

193

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Heat recovery unit of 0.6mm thick Pre-Coated GI sheet Outer skin & 0.6 mm thick GI sheet metal cabinet type plain Inner skin Double skin unit with with 40 mm thick with Thermal break profile, 40 kg/cum polyurethane foam sandwiched between panels complete with pre filter of MERV -8 efficiency at fresh air inlet along with Gridblok IAQ chemical filter with turbulent flow and monolithic structure with 100 mm thick designed for 500 fpm with pressure drop not exceeding 146 pa having density 27.54 lb/ft of along with MERV-13 fine filter at fresh air outlet, MERV-8 filter at return air outlet. Fan section with direct driven plug fan & IE-3 Motor with, IP-21 variable frequency drive shall be suitable for 415 + 10% volts, 50 cycles, 3 phase AC supply. Heat reovery unti shall be wheel type of aluminium with 3 angstorn molecular sieve which is for recovery of both latest and sensible load. The unit shall have two separate passages one for supply of fresh air and the other for exhaust of cool air from the rooms after the recovery of energy, with all accessories as required. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 500 FPM maximum. The unit wheel shall be min. 200 mm thick and shall be capable of recovering atleast 75% latent as well as sensible energy. The unit shall be complete as per drawings and specifications. The Photohydroionization cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions with quad metalic coating (Rohdium, silver, copper and titanimum) and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The honeycomb matrix shall not be accepted. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall conform to UL 1598 CAN/CSA C222 EN60335-1, EN60335-2-65, EU standards, certifications shall be submitted along with the technical submital. Supply air fan - 950 cfm, external static 50 mmwg Exhaust air fan - 1750 cfm, external static 50 mmwg

1

-

-

... More
Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet

1140

-

-

... More
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for for all floor, all level, all height (including all basement) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.

11393

-

-

... More
Providing material and labour for laying broken china mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles (of any shade) to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto surface using white cement including rounding off junctions and extending them upto 15 cm along the wall, curing, clearing with water and oxalic acid etc for all level, all height as directed by engineer in charge.

9219

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Pot STRAINER as specified with SS Jali complete with pair of flanges neoprene gasket. 300mm dia.

1

-

-

... More
Cabling - Multipair Cables Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections. A Conductor Size 0.5 mm. (b) Armoured. (Jelly Filled) (3) Fifty Pairs.

375

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 65 mm dia.

12

-

-

... More
SITC of Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 230 V. 50 Cys. 1200 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2, 3 core flexible wire with earthing

347

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 26.40 TR / 10250 CFM For Reception Waiting & Corridor at Second Floor

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 8.15 TR / 5650 CFM For Corridor at Ground Floor

1

-

-

... More
Providing and arranging in position back side storegae unit (Hinged Door Unit - HDU) of size 1200mm x 1200mm x 450mm. Back and side panel of storage unit shall be made out of 25mm thick plain partical board and both side finished with laminates of approved shade. Doors, Partitions and shelves of storage shall be made of 18mm thick plain partical board and both side finished with laminates of approved shade. Flat edges shall be finished with 2mm thick PVC beading.

18

-

-

... More
Providing and arranging in position Fabric finish mid back chair of Barvo of Godrej or equivalent with approved shade of fabric. The seat and back shall be made up of 12mm thick hot-pressed plywood and upholstered with fabric upholstery covers and moulded polyurethane foam. The one-piece armrests should be injection moulded from black co-polymer polypropylene. Chair shall be of 360° revolving type, upright-position locking, tilt tension adjustment, seat/ back tilting ratio of 1:3, pneumatic height adjustment, telescopic bellow assembly with pedestal injection moulded in black polypropylene, 5 nos. twin wheel castors.

382

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.