Public Works Department Tender

View complete overview of Daman & Diu PWD Tender

Public Works Department - PWD Tender

Works
Solar Installation and Products
Electrical Works
Eprocure
Opening Date4 Apr 2025
Closing Soon30 Apr 2025
Tender Amount₹ 35,22,33,348 
Notes
Download

Costs

Summary

Providing Electrical, Hvac And Solar System Works At Government Hospital

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SITC of mains with 2 nos. of 4 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.

800

-

-

... More
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.95, THD 15%, CCT 3000 K to 6500K, Luminaire efficacy 85 lumens/watt ,LED LED driver efficiency 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet ( Cat-III )

15

-

-

... More
SITC Recessed with trim luminaire Zing with LED (Light Emitting Diode) system power: 24W, Luminous flux of luminaire 2400 lm, Colour temperature of 4000 K, neutral white, CRI 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, Luminaire housing in die-cast aluminium, Polyester powder black coloured coat applied over a 5- stage pre-treatment, Potruted prismatic diffuser for homogenous light distribution, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, electronic control gear, Protection class I, IP 20Ø = 210 mm, Ø (ET) = 196 mm, H = 70 mm Zing 24 W LED 3462

310

-

-

... More
SITC COB based surface mounted downlight luminaire Rea 152 with system power: 25 W, Luminous flux of luminaire 2500 lm, Colour temperature of 4000 K, Neutral white, CRI 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, Luminaire housing in aluminium, Polyester powder grey coloured coat applied over a 5- stage pre-treatment, Clear acrylic with aluminium reflector and a beam angle of 55°, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear, Protection class I, IP 20, Ø = 152 mm, H = 165 mm Rea 25 W 152 LED 3054

202

-

-

... More
SITC COB based surface mounted downlight luminaire Rea 150 with system power: 45W, Luminous flux of luminaire 4500lm, Colour temperature of 4000K, Neutral white, CRI80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, Luminaire housing in aluminium, Polyester powder Black coloured coat applied over a 5- stage pre-treatment, Clear acrylic with reflector with beam angle of 55°, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear,Protection class I, IP 20, Ø = 150 mm, H = 220 mm Rea -45 W LED 3054

6

-

-

... More
SITC Recessed luminaire Solo with HPE (High Performance Efficiency) LED (Light Emitting Diode), system power: 35 W, Luminous flux of luminaire 3500 lm, colour temperature of 4000 K, Neutral white, CRI 80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours, Energy efficient LEDs, Direct light emission, CRCA metal housing with ceiling trim, Polyester powder white coloured coat applied over a 5- stage pre - treatment, Opal diffuser for a homogenous light distribution ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, integral electronic control gear, Protection class I, IP 20, Ø = 330mm, DA(Ø) = 320 mm, H = 106 mm Solo 35 W LED 0113

647

-

-

... More
SITC Recessed ceiling luminaire Solo with LED(Light Emitting Diode) system power: 25 W, luminous flux of luminaire 2500 lm, colour temperature of 4000 K, neutral White, 230V constant current voltage, CRI 80, constant current driver, 70% of luminous flux after 50,000 operating hours, energy-efficient LEDs, direct light emission, metal housing with ceiling trim polyester white powder coat applied over a 5-stage pre-treatment, opal diffuser for glare-free uniform light, integral electronic control gear, Protection class I, IP40, Ø = 330mm, DA(Ø) = 320 mm, H = 106 mm Solo 24 W 330 LED 0113

47

-

-

... More
Surface-mounted Splash essential with HE-High Efficiency LED (Light Emitting Diode) system power: 20W, the luminous flux of luminaire lm 2400lm, the colour temperature of 4000K, CRI 80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours, energy-efficient LEDs with high CRI, direct light emission, luminaire profile in light grey polycarbonate, Opal diffuser for homogenous light distribution, ZHLS(ZERO HALOGEN LOW SMOKE) internal wiring, electronic control gear Protection class I, IP65 L = 1220mm, B = 80mm, H = 69mm Splash Essential 25 W LED 1022

72

-

-

... More
Pendant luminaire Volt S Ring 1500 with HE-High Efficiency LED (Light Emitting Diode) system power: 80W, luminous flux of luminaire 7200lm, colour temperature of 4000K, Neutral white, CRI80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours, direct light emission, curved luminaire profile in aluminium, powder coated White, Prismatic diffuser for uniform illumination, Electronic control gear. Protection class I, IP20 Ø = 1500 mm, B = 55 mm, H = 75 mm, PL max = 1500 mm Volt S Ring80 WATT 1500 LED 0910

12

-

-

... More
COB based LED recessed downlight, Aston, with HPE (High-Performance Efficiency), with system power: 35 W, Luminous flux of luminaire 3500 lm, Colour temperature of 4000 K, Neutral white, CRI 80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours; energy-efficient LEDs, direct light emission, housing in die-cast aluminium, Polyester powderwhite coloured coat applied over a 5-stage pre-treatment ceiling trim, Clear glass cover with aluminium reflector and a beam angle of 55°, ZHLS (ZERO HALOGEN LOW SMOKE) wiring, Electronic control gear,Protection class II, IP 40, Ø = 162 mm, DA(Ø) = 150 mm, H = 180 mm. Aston 35 Watt LED 3138

12

-

-

... More
XLPE armoured cable of 1100 V grade of copper conductor of following size 3C X 6 SQMM CU ARMERED CABLE

685

-

-

... More
XLPE armoured cable of 1100 V grade of copper conductor of following size 4C X 16 SQMM CU ARMERED CABLE

172

-

-

... More
Copper cable of 1100V grade of copper conductor of following size 4C x 70 SQM CU flexibal Cable.

150

-

-

... More
Supply of 4000 mm long,keseles diva combo Decoretiv . GI 76mm & 60mm street light pole with ovel bracker approved shed complete with 316*316mm base plate as per requirement complete in all respect as per drawing. Junction box 80mm*125mm shall be in concealed manner (inside the pole)withone no 6A SP mcb and 4 way 32A Connector strip suitable to terminate armoured cables w Adequate size cutout with opeanable hinged door should beprovided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc,3 core round flexible wire from junction box complete in all respect as per following type posttop Light Fixture with all necessary Hadware, Internal Wiring with Lamp,Ballast etc. all required accessories Complete in all respect. Posttop Light fixture-Make - Keselec VALE 50W WW LED ASYM POST TOP 50 W LED 3000K DECORETIVE IP 66 OPTIC LUMINAIRE WITH ALUMINIUM BODY CLEAR ACCYLIC.

45

-

-

... More
Supply of 7000 mm long,keseles Decoretiv .Casting & Gi botam 166mm & top 76 mm Top street light pole with Singal Arm 1000 mm Henging bracker approved shed complete with 300*300 mm base plate as per requirement complete in all respect as per drawing. Junction box shall be in concealed manner (inside the pole)withone no 6A SP mcb and 4 way 32A Connector strip suitable to terminate armoured cables w Adequate size cutout with opeanable hinged door should beprovided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc,3 core round flexible wire from junction box complete in all respect as peDecorative Light Fixture- following type of LED Pendant type of Luminaires. The housing of the luminaries shall be aluminium spun body suitable for mounting to internally threaded type of designation M30, clear acrylic V diffuser and its cover shall be tempered protective toughened glass.It shall have inbuilt driver with THD 15%;Overvoltage protection,surge voltage protection etc as per .The fixture shall have IP protection of IP65 and impact resistance of IK07.The fixture shall comply 50 Watt with Powerfactor0.9;CRI70;Colour Temperature 3000k,System

35

-

-

... More
Supply, of 750mm*16mm j bolt cable entry pipe 8 swg ciol erathing rcc foundation 1000*600*600mm Concrete foundationwith base plate. Excavation for erection of poles as per drawing complete in all respect Pole

80

-

-

... More
ELW 19.00 UPS Supply, Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 20KVA UPS 3 ph in 3 ph out for balance load

1

-

-

... More
Supply, Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 60KVA UPS 3 ph in 3 ph out for balance load

1

-

-

... More
Supply, Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 80KVA UPS 3 ph in 3 ph out for balance load

1

-

-

... More
ELW 20.00 Exit sign SITC of Self contained single sided exit sign for wall / ceiling / pendant cantilever mounting with 3 W LED tube for Non maintained battery backup emergency lighting for 2 hours duration.Prolite make or approved equal in quality and design.

18

-

-

... More
Sec.3.0 Facade LightingSupplying and erecting, testing and commissioning of Non-Pixel Linear flex Wattage : 14W/MOperating Voltage : DC24VColour : RGB IP Rating : IP67

300

-

-

... More
Supplying and erecting, testing and commissioning of Linear washer Wattage :18WOperating Voltage : DC24VColour : RGBW(W=3000K)Diamension: Lenght 1000mmBeam Angle : 15°x55°IP Rating : IP66IK Rating : IK06

120

-

-

... More
Supplying and erecting, testing and commissioning of Linear washer Wattage :18WOperating Voltage : DC24VColour : RGBW(W=3000K)Diamension: Lenght 1000mmBeam Angle : 15°x55°IP Rating : IP66IK Rating : IK06

80

-

-

... More
Supplying and erecting, testing and commissioning of Flood light Wattage 12WOperating Voltage : DC24VColour :RGBW(W=3000K)Beam Angle : 45°IP Rating : IP66IK Rating : IK08

124

-

-

... More
Supplying and erecting, testing and commissioning of Flood light Wattage 24WOperating Voltage : DC24VColour :RGBW(W=3000K)Beam Angle : 15°IP Rating : IP66IK Rating : IK08

92

-

-

... More
Supplying and erecting, testing and commissioning ofLinear washer Wattage :18WOperating Voltage : DC24VColour : RGBW(W=3000K)Diamension: Lenght 1000mmBeam Angle : 15°x55°IP Rating : IP66IK Rating : IK06

32

-

-

... More
Supplying and erecting, testing and commissioning of Linear washer Wattage :18WOperating Voltage : DC24VColour : RGBW(W=3000K)Diamension: Lenght 1000mmBeam Angle : 15°x55°IP Rating : IP66IK Rating : IK06

40

-

-

... More
Supplying and erecting, testing and commissioning of Aluminium Profile Aluminium profile for Linear Flex

300

-

-

... More
Supplying and erecting, testing and commissioning of Accessories Interconnection cable 2 Mtr/ starter cable

80

-

-

... More
Supplying and erecting, testing and commissioning ofPower Supply AC100~200V input, DC24V output, 200W, constant voltage power supply IP Rating : IP67

70

-

-

... More
Supplying and erecting, testing and commissioning of Main controller

1

-

-

... More
Supplying and erecting, testing and commissioning of Sub controller 8 port sub controller

3

-

-

... More
Supplying and erecting, testing and commissioning of Decoder 3ch decoder

30

-

-

... More
Supplying and erecting, testing and commissioning of Splitter 4ch DMX splitter

8

-

-

... More
Supplying and erecting, testing and commissioning of cat -6 utp cable DMX

4500

-

-

... More
Supplying and erecting, testing and commissioning of controlig wiriring for fassard

2500

-

-

... More
Sec.4.0 Electrical Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. LAUNDRY PANEL-01 ( SLD ). As per Single line diagram.

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. LAUNDRY PANEL-02 ( SLD ). As per Single line diagram.

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. MGPS PANEL-13 ( SLD ). As per Single line diagram.

1

-

-

... More
SITC of 100 A FP MCCB with sheet steel metal enclouser with ELR

3

-

-

... More
SITC of 80 A FP MCCB with sheet steel metal enclouser with ELR

3

-

-

... More
Providing of 32 A x 250 V Plug & socket with interlocked switched socket, DP MCB and surface mounting box FOR laundry.

6

-

-

... More
Providing of 32 A x 440 V Plug & socket with interlocked switched socket, FP MCB and surface mounting box FOR laundry.

2

-

-

... More
Providing of 63 A x 440 V Plug & socket with interlocked switched socket, FP MCB and surface mounting box FOR laundry.

4

-

-

... More
Supply, installation, testing and commissioning of hand held portable operator terminals (POT) minimum 7 inch. TFT display with capacitive touch screen type, shall be able to view graphs , alarms , parameters etc. POT shall have integrated web server and a BACnet/ IP web interface to connect a HTML5 browser to a device on the network. POT With all required connectors etc as per technical specification etc.

1

-

-

... More
Field instruments Supplying, installing, testing and commissioning of the following sensors/ transmitters. The DDC shall support sensor with 4...20 mA, DC 0 ... 10 V, LG-Ni 1000, 2x LG-Ni1000, Pt 1000 , NTC 10k, NTC 100k, 1000 Ohm. Supply, Installation, Testing, Commissioning of Outdoor type Ambient Temperature with Humidity Sensor with radiation shield, IP65 rated(Temp Range -30 to +50 °C, RH: 0-100 %). as per technical specification etc. as required.

1

-

-

... More
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Blower status ( Min 100- 1000 PA).as per specifcation

54

-

-

... More
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Filter status (Min 30- 300 PA) as per specifcation

54

-

-

... More
Supply, Installation, Testing, Commissioning of Duct Type Temperature with Humidity Sensor, IP65 rated with RH accuracy 5%, temp accuracy +_ 0.7 deg (-40 to 70 Degree)

54

-

-

... More
Supply, Installation, Testing, Commissioning of Air Type Differential Pressure Transmitter( 0-3000 PA) Across AHU/ CSU Blower.

54

-

-

... More
Supply, Installation, Testing, Commissioning of Water Type absolute Pressure Transmitter, range should be Min 0-10Bar, 0-10V Output To know actual pressure in supply line, Output actual pressure of pump.

16

-

-

... More
Supply, Installation, Testing, Commissioning of Water Type Differential Pressure Switch

12

-

-

... More
Supply, Installation, Testing, Commissioning of Immersion Temperature Sensor,IP 65 rated thermister type, LG-Ni 0.15m with SS Thermowell.

8

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic type Flow Meter

2

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic type Level Transmitter (5mtr. Depth )

24

-

-

... More
Supply, Installation, Testing, Commissioning of Water Type Differential Pressure Sensor

4

-

-

... More
Supply, Installation, Testing, Commissioning of Water Type Water Flow switch

4

-

-

... More
Supply, Installation, Testing, Commissioning of High & Low Level Switch for Cooling Tower (Max 1mtr. Depth )

4

-

-

... More
Supply, Installation, Testing, Commissioning of Room Type Co2 Monitoring for Fresh Air ( Measuring Range :- 0-2000 ppm Co2)

39

-

-

... More
IBMS Cabling- Supplying, laying , testing and commissioning of 2 Core X 1.0 Sqmm Shielded Copper Cable (per I/O points hard wired to DDC). as per technical specification etc. as required.

14119.2

-

-

... More
Supplying, laying, testing and commissioning of 4 Core X 1.0 Sqmm UnShielded Flexible Copper Cable (per I/O points hard wired to DDC). as per technical specification etc. as required.

11143

-

-

... More
Supplying, laying, testing and commissioning of 4 Core X 1.0 Sqmm Shielded Copper Cable (per I/O points hard wired to DDC). as per technical specification etc. as required.

5337.2

-

-

... More
Supplying, laying, testing and commissioning of 2 Core X 1.5 Sqmm Shielded Copper Cable (per Soft I/O points to DDC). as per technical specification etc. as required.

3000

-

-

... More
Supplying, laying , testing and commissioning of 3 Core X 1.5 Sqmm Flexible Cable (per DDC to UPS Power Supply). as per technical specification etc. as required.

2000

-

-

... More
HVAC - VRV SYSTEM Lifting & Shifting, Supply, Installation, Testing, Commissioning of floor mounted top / side discharge type AC Outdoor unit with Variable refrigerant flow system with required indoor units, refrigerant piping, refnet connection, individual controller, Necessary integrator for BMS with open protocol. The quote for the work should include necessary, lifting charges for mounting the Condensing units with rubber pads, first charge of 410A refrigerant and mounting of indoor units and other accessories. The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired, tested with all necessary controls. The outdoor unit shall be modular in design and should be allowed for side by side installation. Each modular inverter outdoor shall be having minimum 1 digltal scroll / inverter & 1 fixed scroll compressors , Heat exchanger, condenser fan etc., capable to operate at 3 Phase, 415 +/- 10 % Volts, 50hz power supply. The unit shall be provided with its own microprocessor control panel & electrical compartment with all necessary electrical and control components. Supply of Variable Refrigerant System with all accessories ( Make : DAIKIN ) VRF Out-door Units ( 60 H.P. )

2

-

-

... More
36 H.P.

2

-

-

... More
28 H.P.

1

-

-

... More
16 H.P.

1

-

-

... More
12 H.P.

1

-

-

... More
08 H.P.

2

-

-

... More
Indoor Units Wall Mounted type VRF IDU 1.5 TR

4

-

-

... More
Indoor Units Wall Mounted type VRF IDU 2.0 TR

14

-

-

... More
Ceiling mounted 4way-Cassette Type VRF IDU 0.6 TR

2

-

-

... More
Ceiling mounted 4way-Cassette Type VRF IDU 1.5 TR

2

-

-

... More
Ceiling mounted 4way-Cassette Type VRF IDU 2.0 TR

2

-

-

... More
Ceiling mounted 4way-Cassette Type VRF IDU 2.5 TR

8

-

-

... More
Ceiling mounted 4way-Cassette Type VRF IDU 3.3 TR

8

-

-

... More
Ceiling Suspended Ductable type high staic unit 4.0 TR

5

-

-

... More
Ceiling Suspended Ductable type high staic unit 6.0 TR

2

-

-

... More
Ceiling Suspended Ductable type high staic unit 8.0 TR

9

-

-

... More
Remote Controllers Corded Remote Controllers for VRV System to modulationg Temprature and adjust fan speed of indoor unit. ( Cooling Mode )

22

-

-

... More
Cordless Remote Controllers for VRV System to modulationg Temprature and adjust fan speed of indoor unit. ( Cooling Mode )

40

-

-

... More
Central Remote Controller for above system comprising of all required Software. PC will be supplied by client. System should control & monitor all installed IDU / ODU. Following should be minimum controlling & monitoring features that system should cover; Start / Stop, Temperature settings, Mode control, Group formation, view alarms, Fault Diagnosis.

2

-

-

... More
All refrigerant joints with insulation

63

-

-

... More
Supply & laying of copper sheilded communication cable as per OEM size.

1000

-

-

... More
Supply, installation, Testing & Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 60 H.P. SYSTEM

2

-

-

... More
Supply, installation, Testing & Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 36 H.P. SYSTEM

2

-

-

... More
Supply, installation, Testing & Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 28 H.P. SYSTEM

1

-

-

... More
Supply, installation, Testing & Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 16 H.P. SYSTEM

1

-

-

... More
Supply, installation, Testing & Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 12 H.P. SYSTEM

1

-

-

... More
Supply, installation, Testing & Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 08 H.P. SYSTEM

2

-

-

... More
Mechanical Ventilation for Toilet Supply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specifications with site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres. 400 CFM Inline Axial Exhuast Fan for Toilet ( Floor Mounted )

2

-

-

... More
Mechanical Ventilation for Toilet Supply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specifications with site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres. 1000 CFM Inline Axial Exhuast Fan for Toilet ( Floor Mounted )

2

-

-

... More
Mechanical Ventilation for Toilet Supply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specifications with site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres. 1100 CFM Inline Axial Exhuast Fan for Dirty Room & Store Area ( Floor Mounted )

2

-

-

... More
Mechanical Ventilation for Toilet Supply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specifications with site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres. 1100 CFM Inline Axial Fresh Air Fan for Dirty Room & Store Area ( Floor Mounted )

2

-

-

... More
Mechanical Ventilation for Toilet Supply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specifications with site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres. 1200 CFM Inline Axial Fresh Air Fan for Room & Passage Area ( Floor Mounted )

2

-

-

... More
Mechanical Ventilation for Toilet Supply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specifications with site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres. 1800 CFM Inline Axial Fresh Air Fan for Room & Passage Area ( Floor Mounted )

2

-

-

... More
M. S. structure for installing VRF / DX outdoor units duly epoxy coated / galvanized.

2

-

-

... More
Fire Retardant Canvass connections

34

-

-

... More
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 32mm dia.

100

-

-

... More
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 25 mm dia.

250

-

-

... More
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 19 mm dia.

100

-

-

... More
insulation work Supplying, fixing Duct Acoustic Insulation of open cell nitrile rubber sheet having density of 180-220 kg/m3 and recommanded thickness of 15 mm. It shall be fixed inside of the duct with the help of adhesive complete as per specifications and as required. 15mm

750

-

-

... More
insulation work Supply & Installation of Under Deck Insulation with Class ‘O’ Nitrile Rubber with tough Aluminum foil facing & as per detail specifications - 25mm

1600

-

-

... More
Refrigerent charge of VRV system with Nitrogen pressure testing, vaccume test & all neccesary activity with eco-friendly refrigerent gas as per site conditions.

9

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 4220 CFM 10.64 TR for PICU Ward

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 6245 CFM & 14.77 TR for NICU ward/Nurse station

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 4865 CFM & 17.8 TR

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 11935 CFM & 26.43 TR

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows. 2000 CFM & 4.0 TR for Septic Dialysis at Second Floor

2

-

-

... More
Treaed Fresh Air Unit Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Mounted / Loft Mounted Treated Fresh Air Unit as specified below; Double Skinned with inner & powder coated outer skin of 0.8 mm, Density 40 Kg / m³ & 40 mm thick PUF Sandwitched insulated sectionalized construction Comprising of Fan section with best efficiency Plug Fan driven by suitable pole Eff - 1 Motor with VFD, IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with 20+10 micron pre filter, Cooling coil section complete with Copper tube 13 FPI AL finned 6 / 8 R deep DX cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, necessary vibration isolation arrangement by providing spring isolators; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Panel supplied with matching rating for Fan motor, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, 5 RMT. Cables from AHU Panel to AHU, UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible Temp control thermostat with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: Fan Exit velocity=1800 FPM; Coil Face Velocity=500 FPM max; Filter Face=400 FPM max; dB=60 at 1 M distance. Price shall be complete with alluminium anodized duct dampers along with fire retardant canvass connections for supply & Fresh air; AHU dimensions, configuration (single-tier / double-tier, top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Price shall includes AHU kit With electronic expansion valve, microprosser & necessary things to connect outdoor units of Variable Refrigerant System as specified below - 6.0 TR / 1600 CFM @ 50 mm Static Capacity for 8 HP VRV ODU

2

-

-

... More
9.0 TR / 2500 CFM @ 50 mm Static Capacity for 12 HP VRV ODU

1

-

-

... More
12.0 TR / 3200 CFM @ 50 mm Static Capacity for 16 HP VRV ODU

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / Hot Water multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 400 CFM (HI WALL)

2

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 3900 CFM / 40mm Static Pressure for Toilet

1

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 500 CFM / 25 mm SP for Dirty Utility Exhaust

2

-

-

... More
Sec Air Moving Equipment Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 11350 CFM / 27.70 TR For PICU, NICU, Nurse Station & Passage at Ground Floor

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 4300 CFM / 6.12 TR With 1.50 kW Strip Heaters & Humidistate For CT Scan Room at Ground Floor

1

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD) by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration) 6850 CFM / 14.10 TR For Pre Op Room and Corridor at Second Floor

2

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 500 CFM

9

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 600 CFM

3

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / Hot Water multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built 2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with "Y" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 500 CFM

9

-

-

... More
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / Hot Water multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built 2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with "Y" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 600 CFM

3

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 3900 CFM / 40mm Static Pressure for Toilet

1

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 3450 CFM / 40mm Static Pressure for Toilet

2

-

-

... More
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 2600 CFM / 40mm Static Pressure for Toilet

1

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 200 mm dia.(32 mm thick insulation)

240

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 150 mm dia.(32 mm thick insulation)

110

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 125 mm dia.(32 mm thick insulation)

20

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 80 mm dia.(32 mm thick insulation)

68

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 65 mm dia.(32 mm thick insulation)

40

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 50 mm dia.(32 mm thick insulation)

70

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 40 mm dia.(32 mm thick insulation)

10

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 32 mm dia.(19 mm thick insulation)

100

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 25 mm dia.(19 mm thick insulation)

60

-

-

... More
INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint). Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 19 mm dia.(19 mm thick insulation)

170

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 125mm dia.

2

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 80mm dia.

4

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 65mm dia.

8

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified 50mm dia.

8

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. AUTO BALANCING VALVE complete with Flanges Nutbolts and Working parts 80mm dia.

1

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 65mm dia.

2

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 50mm dia.

2

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

8

-

-

... More
Providing & fixing in position the mercury in glass industrial type thermometres.

8

-

-

... More
Supplying, fixing, testing and commissioning of wafer type Butterfly Valve as per IS 13095 with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 80mm dia.

4

-

-

... More
Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for 40 mm dia.

2

-

-

... More
Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for 32 mm dia.

2

-

-

... More
Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for 25 mm dia.

2

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of CI Y Strainer with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for: 32mm dia.

2

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts. 25mm dia.

6

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Supplying, fixing, testing and commissioning of Automatic Air Purge Valve at AHU chilled water outlet pipe duly insulated to the same specifications as the connected piping and adequately supported as per specifications. 20mm dia.

14

-

-

... More
SITC 100MM DIAL PG 0-10 KG/CM2 Supply & Installation of dial type Pressure Gauge 100 mm size with SS needle valve and fittings 0-10 kg / cm2 range installed as per P & I Diagram.

4

-

-

... More
SITC 100MM DIAL TG 0-50 DEG C Supply & Installation of dial type Temperature Gauge 100 mm size with SS thermowell / coupling / glycerine or eq. conductive fulid and fittings 0 - 50 °C range installed as per P&I diagram.

4

-

-

... More
Supplying, fixing, testing and commissioning of Brass ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping as per specification 40mm dia.

6

-

-

... More
Supplying, fixing, testing and commissioning of Brass ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping as per specification 32mm dia.

14

-

-

... More
Supplying, fixing, testing and commissioning of Brass ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping as per specification 25 mm dia.

8

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of Automatic Air Purge Valve at AHU chilled water outlet pipe duly insulated to the same specifications as the connected piping and adequately supported as per specifications. 20mm dia.

20

-

-

... More
INSULATED VALVES Supply, Installation, Testing and Commissioning of following sizes 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 65mm dia.

1

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 50mm dia.

1

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 40mm dia.

2

-

-

... More
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 25 mm dia.

10

-

-

... More
BALL VALVE WITH STRAINER 25 mm Dia

8

-

-

... More
Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet

2268

-

-

... More
Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet

719

-

-

... More
Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.00 mm sheet

180

-

-

... More
Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet

350

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet

150

-

-

... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.

18

-

-

... More
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq. mm) for integration within AHU room Damper

5

-

-

... More
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq. mm) for integration within AHU room Actuator

6

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

18

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

40

-

-

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

18

-

-

... More
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

18

-

-

... More
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. 200mm dia.

200

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire Damper

10

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Actuator

10

-

-

... More
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.

150

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. and above Bonded Treated Woven Glass Fibre for Outer covering of Insulation Material GC bonded applied by suitable adhesive. Density: 200 +/- 20 gsm Thickness: 0.18 mm / 7 mill, The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm

3600

-

-

... More
25 mm Dia.

550

-

-

... More
40 mm Dia.

30

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. and above Bonded Treated Woven Glass Fibre for Outer covering of Insulation Material GC bonded applied by suitable adhesive. Density: 200 +/- 20 gsm Thickness: 0.18 mm / 7 mill, The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 25mm

450

-

-

... More
CABLE TRAYS Supplying and fixing following sizes of GI Ladder type cable trays including couplers,fittings and other accessories as required, and duly suspended from the ceiling with suspenders/fixed on ceiling / walls on fastners etc as per specifications complete as required. 300 x 50 mm

100

-

-

... More
150 x 50 mm

50

-

-

... More
Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. For Chiller Plant of 650 Tr & VRV Plant of 264 Hp Only Opearation Cost During DLP

1

-

-

... More
Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. For Chiller Plant of 650 Tr & VRV Plant of 264 Hp 1st Year after DLP

1

-

-

... More
Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. For Chiller Plant of 650 Tr & VRV Plant of 264 HP 2nd Year after DLP

1

-

-

... More
Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. For Chiller Plant of 650 Tr & VRV Plant of 264 HP 3rd Year after DLP

1

-

-

... More
Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. For Chiller Plant of 650 Tr & VRV Plant of 264 HP 4th Year after DLP

1

-

-

... More
Operation & Maintenance Works SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system & VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. For Chiller Plant of 650 Tr & VRV Plant of 264 HP 5th Year after DLP

1

-

-

... More
SOLAR PLANT Design, Engineering, Supply, Installation, Testing & Commissioning of 10 KWp Grid connected Solar PV Power Plant consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc.

8

-

-

... More
SOLAR PLANT Design, Engineering, Supply, Installation, Testing & Commissioning of 20 KWp Grid connected Solar PV Power Plant consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc.

6

-

-

... More
SOLAR PLANT Design, Engineering, Supply, Installation, Testing & Commissioning of 35 KWp Grid connected Solar PV Power Plant consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc.

6

-

-

... More
ELW 02.00 HT PANEL Supplying, Testing & Commissioning of HT VCB panel consisting of 1 no. of 400A HT VCB as incoming and 3 nos of 400A VCB as outgoing. The panel should have tinned copper busbars and extensible type for future requirements. The Panel should be complete with metering and protection as per specification. (Extensible type)

1

-

-

... More
HT RMU Supplying, Erecting, Testing & Commissioning of 3 Way RMU , 11KV, which should be have 1 Incomer Isolators of 630A and 2 outgoing SF6 Insulated Vaccume circuit Breakers of 630 A for Transformers protection, All functions Of Isolators and Breakers should be supplied with Motorised Mechanism for remote operation ON/OFF of RMU, Each Isolators and Each Breaker function should be supplied with motorized mechasism and also with electrical and Mechanical Interlocking

1

-

-

... More
Compact Sub station Supply, Testing & Commissioning of 1600 KVA Unitized Sub-station consisting of (1 no 400 A HT VCB as incomer + 1600 KVA Dry type Transformer with OLTC and RTCC Panel +2500 A FP MCCB L.T. Switchgear with all connection accessories, fitting & auxiliary equipment in an Enclosure to supply Low-voltage energy from high-voltage system as detailed in this specification. The complete unit shall be installed on a substation plinth (base) as Outdoor substation located at very congested places as direct engineer in charge

2

-

-

... More
BUSDUCT & RISING MAINS & its accesories Supplying, assembling, grouting in slab / wall / beam with hanging rods/ strips / supports, water proof, dust proof, vermin proof busduct to be fabricated out of 14 gauge sheet. The busduct should be processed through 7 tank process. The busduct should be powder coated. All joints should be fitted with neoprene gasket. The busduct should confirm to IP 55 protection.The capacity of the busbar should be 2500 FP Amps & should be of tinned Aluminium, with necessary flexible, bends, reducer, expansion joints, supports and all assential accessories complete in all respect. Necessary certificate shall be required at the time of supply. The capacity of neutral bus should be equal to phase bus. (INDOOR DUTY WITH 2NOS. AL. EARTHING STRIP) ( CSS to Stabilizer to Main LT Power Panel & DG SYCN. PANEL TO Main LT Power Panel)

135

-

-

... More
ELW 06.00 MV Switch Gear and power Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect MAIN LT POWER PANEL As per Single line diagram (panel must be with gas based fire suppresion system)

1

-

-

... More
ELW 06.00 MV Switch Gear and power Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect DG SYNC. PANEL As per Single line diagram (panel must be with gas based fire suppresion system)

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect 350KVAR APFCR PANEL As per Single line diagram (panel must be with gas based fire suppresion system)

4

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. UTILITY BLOCK PANEL As per Single line diagram

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. POST MORTEM BLOCK PANEL As per Single line diagram

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. CANTEEN BLOCK PANEL As per Single line diagram

1

-

-

... More
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. EXTERNAL LIGHTING PANEL As per Single line diagram

1

-

-

... More
DG Set with AMF panel Supplying, installation, testing and commissioning of DG set of 2#1000 KVA with approximate 1180 BHP engine with enclouser & suitable alternator complete with all necessary fuel piping,Aluminium cladding, exhaust piping, control panel, Auto synchronizing, auto load sharing AMF Panel, silencer & its piping, Acoustic silencer, Alternator cable termination box suitable for Aluminium cables,initial battery charging,base frame, battery and charger complete in all respect. Scope also includes preparing necessary drawing submitting to authorities, getting their approval / sanction and final certificate including NOC from pollution board(if required) to energize the D G Set . (Rate Includes 2 Nos. of 1000 kVA Dg sets, 2 Nos. Control & AMF Panels and 2 No. of RECD kit etc.)

1

-

-

... More
EXHAUST SYSTEM Dia 12" / 300mm, MS ERW B Class Pipe. Shall be duly cleaned with Wire Brush and Coated with 1 coat of Primer & 2 coats of Heat Resistant Paint, Exhaust pipe Thermal Insulation and cladding for 12"dia pipe, using Rockwool Insulation of density 64Kg/m3 with 50mm thick bound with GI chicken wire mesh & Cladding using 24 SWG Aluminium sheet, 12" SS Flexible Bellows with Table D Flanges, Gaskets and Hardwares, Thermal Insulation and cladding of Silencers, using Rockwool Insulation of density 64Kg/m3 with 50mm thick bound with GI chicken wire mesh & Cladding using 24 SWG Aluminium sheet, M.S Structural Supports for Exhaust Stack, cable trays, Fuel pipes using ISA / ISMC. Supports shall be Duly Cleaned with Brush follwed by One Coat of Primer and Two Coats of Synthetic Enamel Paint / Aluminium Paint, Lightning Arrestor - Convetional - Spike and Sphere Type, Aviation Lamp - LED Type, 25 x 3 CU Strip for LA earthing with insulators, CU Earth pit for Lightening Arrestor earthing (600x600x3.15mm Cu Plate, 3 Mtrs of Dia 40 mm GI B Class Pipe, 2 Runs of 25x3 Cu strip & Funnel arrangement)

1

-

-

... More
SUPPLY AND INSTALLATION OF OUTDOOR KIOSK LBS WITH VCB PANEL WITH CTPT ARRANGEMENT Dust and Vermin Proof FT Profile Water Resistant Switch Board Complete set of an Outdoor 800 AMP LBS + 1250 AVCB Panel with CT-PT Cubicle Arrangement 2mm Sheet steel structure, 5 mm steel supporting load barring structure with anti corrosive chemical treatment & powder coated RAL 7032 including 1)11 KV VCB cubicle board with inbuilt rack in/out trolly & ramp for removal directly on floor 1250 Amp, 230V AC Spring charged motor, 110V DC trip & closing Coil, manual spring charged handle, E stop mechanical push button 1) 11KV LBS -800Amp, built in earth switch, single phasing protection assembly, aux contect 2) 11 KV current transformer : 400/5A, 10VA, 5P10 3) Numerical relay - 3-O/C, 1-E/F,, 4) Master trip LocKout relay, 5)AUx transformer relay. 6) anti pumping feature scheme 7) 8 -windowannaunciator 8) Push button - LBS off, indication on off 9) indicationVCB on off, trip, spring charged, TCH spring charged, Push button VCBon off 10)power pack - 230V/ 110 v DC, 7 AH 30 Min, 3-closing tripping strock back up. 11) Set of 1-P, 2P MCBs. 12) spaeceheater with termostate with on/off switch and utility socket. 13) provision of cable termination with bimetalick strip on copper busbar ends for alluminnium cable termination. 14) isolated CT-PT cubical separate metering cubicle . Complete in all respect including all required for the same.

1

-

-

... More
Supply, Installation, Testing of 11 KV 3Phase*4 Wire HT Bi directional Meter Accuracy Class 0.2s Make : Secure. Complete in all respect including all required for the same.

1

-

-

... More
Supply, Installation, Testing of 11 KV 3Phase*4 Wire Metering CTPT Unit Accuracy Class 0.2s Ratio : 150/5 Amp. Complete in all respect including all required for the same.

1

-

-

... More
Supply, Installation, Testing of LT Metering set including Secure Make LT meter, Resin Cast CT coil, LT meter box. Complete in all respect including all required for the same.

1

-

-

... More
Supply of GPRS/ GSM MODEM with CODE and Antenna. Complete in all respect including all required for the same. Make Secure

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.