Planning And Development Department Tender

View complete overview of Daman & Diu Planning And Development Department Tender

Planning And Development Department Tender

Building Construction
Eprocure
Opening Date8 Sep 2021
Closing Date23 Sep 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling in plinth with sand under floors including watering ramming, consolidating and dressing as directed by engineer in charge complete (more than 10 ton)

166.73

-

-

... More
Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. as directed by engineer in charge complete (more than 10 ton)

473.38

-

-

... More
Providing and filling rubbles including hand packing and filling voids with sand as directed including ramming and consolidating etc. Complete as directed by Engineer-in-charge.

37.34

-

-

... More
CONCRETE & REINFORCEMENT WORKS Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (more than 10 ton) as directed by engineer in charge complete

69.9

-

-

... More
Providing Thermo Mechanically Treated bar (T.M.T.) (I.S.I. Mark) conforming to I.S. - 1786 Fe-500D CRS Steel including providing fusion bonded Epoxy coating not less than 175 micron thickness and up to 300 micron to reinforcement bars as per IS-13620- 1993/ ASTM-775M. for R.C.C. work including bending, binding and placing in position etc. complete as directed by engineer in charge complete

42508.06

-

-

... More
Extra for additional lift of concrete for all R.C.C. work above floor two level excluding cost of reinforcment as directed by engineer in charge complete (upto 10 ton)

25.93

-

-

... More
Extra for additional lift of reinforcing steel for all R.C.C. work above floor two level as directed by engineer in charge complete (upto 10 ton)

4665.08

-

-

... More
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete works as directed by engineer in charge complete for (A) Foundations, footings, Base of columns and Mass concrete

81.85

-

-

... More
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work as directed by engineer in charge complete for RCC Walls at All Floor

9.15

-

-

... More
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work as directed by engineer in charge complete for Tie Beams/ Beams/ Lintel/ Coping at All Floor Slab Level

100.86

-

-

... More
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work as directed by engineer in charge complete for Slab and Weathersheds at All Floor Slab Level

144.04

-

-

... More
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work as directed by engineer in charge complete for (D) Columns, Pillars posts and struts All Floor

45.12

-

-

... More
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work as directed by engineer in charge complete for Staircase at All Floor

7.39

-

-

... More
Providing and fixing CAPCELL HD - 100 pre-moulded compressible filler board in black colour confirming to MoRT&H Specifications (Clause 1015), having minimum density 95kg/cum.metre, non-staining with less than 1% water absorption & compression recovery of 93% minimum as per specification for 12 mm wide expansion joint including cutting to required size and shape at all levels etc. complete as directed by engineer in charge complete

8.42

-

-

... More
Caring out plinth treatment to post construction / existing structure by spraying chemical solution for termite control treatment including labour and material consistent with I.S.I specification. Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-II Concentration Weight one percent is recommended i.e. one litre 20 EC chemical emulsion with 19 litre give 1 % concentration inclusive of one litre chemical emulsion application at the rate of 5 Litre chemical / Sqm of surface is recommended as per I.S (as directed by engineer in charge complete)

330.05

-

-

... More
BRICKWORK Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand) as directed by engineer in charge complete (B) Conventional (more than 10 ton)

234.24

-

-

... More
Extra for brick work in superstructure above plinth level upto floor two level as directed by engineer in charge complete (B) Conventional

210.41

-

-

... More
Extra for brick work in superstructure above floor two level Item No. 1(6.12) as directed by engineer in charge complete (B) Conventional (more than 10 ton)

52.15

-

-

... More
(i) Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in foundation and plinth as directed by engineer in charge complete (B) Conventional (more than 10 ton)

25

-

-

... More
Extra for half brick masonry in superstructure above plinth level upto floor two level as directed by engineer in charge complete (B) Conventional

25

-

-

... More
Extra for half brick masonry in superstructure above floor two level as directed by engineer in charge complete.(B) Conventional (more than 10 ton)

25

-

-

... More
PLASTER WORK Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) as directed by engineer in charge complete

2205.65

-

-

... More
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) MALA PLASTER Extra over items for finishing with a floating coat of neat cement slurry. (upto 10 ton) as directed by engineer in charge complete

2205.65

-

-

... More
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) as directed by engineer in charge complete Extra over items for providing and mixing water proofing materials in cement mortar in proportion recommended by the manufacturer.

300

-

-

... More
Extra over items 58 to 71 for plastering on ceilings and sofits of stairs upto floor two level instead of plastering on walls as directed by engineer in charge complete

675.56

-

-

... More
20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. as directed by engineer in charge complete

948.7

-

-

... More
Providing cement vata (10cm. x 10 cm. size) quarter round in cement mortar 1:1 including neat cement finishing, watering etc. as directed by engineer in charge complete

137.72

-

-

... More
FLOORING & STONE WORKS P & L 24" x 24" vitrified 8 mm thick tile in flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) and for skirting oover 1:3 (1 cement: 3 sand) rough plaster for skirting not more than 100mm high on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. as directed by engineer in charge complete for DARK shade (upto 10 ton)

479.74

-

-

... More
Providing and laying Leather finish Granite stone flooring, and skirting and for treads and risers for staircase in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), or backing coat of cement plaster 1:3 (1 cement: 3sand), laid and jointed with cement slurry or cement paste and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing, molding edges and polishing etc. all complete as specified and as directed by engineer in charge complete : a. Weathered finish granite stone slab, Jet Black,J.D Brown,Cherry Red, Elite Brown, Cat Eye or equivalent.

224.57

-

-

... More
Providing and laying 600m x 600mm vitrified tiles, 8 to 10mm thick of approved shade, colour, size and pattern in skirting, risers of steps and dedo on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse sand) & jointed with white cement slurry including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including 3mm Spacers, Rubbing, Cleaning etc. as directed by engineer in charge complete RAK, Kajaria or Equivalent

142.69

-

-

... More
Providing and laying 600mm x 600mm vitrified 10 mm thick anti-skid tiles of approved shade and colour laid on a bed of cement mortar 1:6 (1 cement: 6 sand), having 20mm average thickness including a 4mm thick float of cement mixed with approved make waterproofing additive as per the manufacturers specification, including filling the joint with pigmented white cement slurry of matching shade including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including 3mm Spacers, Rubbing, Cleaning etc as directed by engineer in charge complete RAK, Kajaria or Equivalent

60.64

-

-

... More
Providing and fixing sandwich type platform consisting of a base of 25mmthk Kotah stone supported on kota stone verticals spaced no further than 1.5m with a granite top, 20mm thick placed and fixed using cement paste, including vertical sides and 100mm facia patti of granite of approved shade and colour including polishing, curing, etc. as directed by engineer in charge complete

3.22

-

-

... More
Providing waterproofing in sunk slabs and terrace using Liquid-applied, Water-Based, Elastomeric Polyurethane Membrane having UV resistance, underground ground-chemical resistance, high melting points, flexible and elastic with high adhesive strength. The membrane shall be reinforced with a layer of non-woven polyester fabric of minimum 40 g/sqm. The upper surface shall be finished with 8-12 sieve quartz sand which shall be sprinkled on to the final wet layer of the liquid applied membrane, to provide ‘keying’ to the subsequent protective cementitious layer of 1:3 plaster (1cement : 3 sand) plaster. The total membrane thickness shall be as specified by the manufacturer’s technical literature but not less that 1.5 mm and shall be applied in 3 coats etc complete as as directed by engineer in charge complete

299.33

-

-

... More
Providing and laying broken china mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto surface using white cement including rounding off junctions, and sealing with cement vata and extending them upto 15 cm along the wall, clearing with water and oxalic acid etc. as as directed by engineer in charge complete

263.05

-

-

... More
Providing and fixing pre-cast Rubber Dye inter locking concrete block 60 mm thick with grade of concrete M40 pumatic compressed by mechanically pressed and as per approved desing including 35 mm sand layer for levelling and filling the joint with sand in proper line and level as directed by engineer in charge complete Vyara or Equivalent

137.84

-

-

... More
PAINTING WORKS Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.

2186.85

-

-

... More
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth as directed by engineer in charge complete Extra over item for every subsequent coat of wall painting with plastic emulsion pain of approved brand.

100

-

-

... More
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth as directed by engineer in charge complete Extra over item for painting with plastic emulsion paint of approved brand on ceilings and sloping roofs.

700

-

-

... More
Finishing wall with weather proof exterior Texture Paint of approved brand (APEX or equivalent) on wall surface (min. two coats) to give an required Texture and Shade as per approved Architectural Elevations after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc. complete as per the instructions of Architect and Engineer In-charge.

948.7

-

-

... More
Applying two coats of Birla (white cement based) or Asian (acrylic lapy- putty) or equivalent & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth as directed by engineer in charge complete

2186.85

-

-

... More
Applying general insecticide pest control treatment to floors, cupboards etc including labour material etc. complete. Using Heptachloride 20 EC. As Per 6113_pests Consentration Weight 0.50 percent is recommended one litre chemical emulsion dillute with 39 liter of water will give. Total dillute concrentration will be 40 litre inclusive of one litre chemical emulsion appication 0.5 Litre chemical / Sqm of surface is recommended as per I.S and as directed by engineer in charge complete

703.93

-

-

... More
STEEL,IRON & WOOD WORKS Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through their entire length and jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arragements for inside and outside locking with push-pull operation including the cost of hood cover and spring etc. as directed by engineer in charge complete (A) Shutters having width below 3.5 M.

211.2

-

-

... More
Providing and fixing 27.5 cm. lcng wire spring grade No.2 of approved make for rolling shutters as directed by engineer in charge complete

44

-

-

... More
Providing and fixing Hood cover for rolling shutters (A) Shutters having width below 3.5 meters as directed by engineer in charge complete

74.8

-

-

... More
Providing and fixing standared extruded of alluminium section of size 63mm x 38.10mm x 1.2mm (Jindal Section :2434, @ Wt. 0.643 Kg/mt) with colour anodized alluminium frame for ventilation with 5 mm thick frosted glass as details etc as directed by engineer in charge complete for Ventilation

2.94

-

-

... More
Providing and fixing standared extruded of alluminium section of size 63.50 x 38.10 x 1.95 mm(of Jindal Section no:4605,@ Wt 1.094Kg / Rmt with colour anodized alluminium frame with 5 mm thick transparent bronze colour tinted float glass as details etc as directed by engineer in charge complete for Fix window.

23.72

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as as directed by engineer in charge complete (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

824.51

-

-

... More
Providing and fixing 38 mm thick Single Shutter Flush Doors using Teak Wood Frame of size 75 x 150 mm having BWP Shutters with both size Decorative Laminate fixed with waterproof adhesives having pattern and brand as approved by the Architect, with Stainless Steel Handles, Tower Bolt (Door Stopper) & Heavy Stainless steel Aldrop including fixing of all other accessories of approved brand as per detailed drawing / as directed by engineer in charge complete door size (1000mm * 2100mm)

9.9

-

-

... More
Providing and fixing 38 mm thick Single Shutter Flush Doors using Granite Frame with both size Decorative Laminate fixed with waterproof adhesives having pattern and brand as approved by the Architect, with Stainless Steel Handles, Tower Bolt (Door Stopper) & Heavy Stainless steel Aldrop including fixing of all other accessories of approved brand as per detailed drawing / as directed by Engineer In-charge Complete (800*2100mm)

8.22

-

-

... More
WATER TANK Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. (as directed by engineer in charge complete)

30

-

-

... More
Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. (as directed by engineer in charge complete)

40

-

-

... More
Providing and placing in position while concreting of RCC Wall for Underground Water tank, PVC Rung of approved size and colour inlcuding making cut-outs for the same in the formwork and securing the same in place so as to create firm hold within the concrete mass etc as directed by engineer in charge complete

8

-

-

... More
Supply, checking, storing and fixing in position European water closet comprising of Wall hung European W.C. MODEL JAQUAR(ESSCO)-MVS-WHT-951SPP in white colour, on approved type of chairs, flushing tank MODEL:JAQUAR(ESSCO)-WHE-WHT-183T as directed,C.P health faucet MODEL:JAQUAR(ESSCO)-ALE-ESS-583 with required length of flexible tube, clamp and bracket for fixing to wall,15 mm C.P. brass heavy quality angle stop cocks MODEL:JAQUAR(ESSCO)-MQT-526KN for flushing tank,C.P. brass 2-way bib cock MODEL:JAQUAR(ESSCO)-MQT-512ANKN ,Solid bakelite water closet cover and seat with C.P. hinges and rubber buffers,Fixing W.C. unit with brackets and accessories in position,Necessary pipe connection to PVC / PP / CI soil pipe,Painting bracket with two coats of white enamel paint over a coat of primer. (as directed by engineer in charge complete)

4

-

-

... More
Supply, checking, storing and fixing Under Counter wash hand basin MODEL:JAQUAR(ESSCO)-MVS-WHT-801 ith ,32 mm heavy plated C.P. waste coupling JAQUAR(ESSCO)-ALE-544NFT fitting with pop-up,32 mm heavy plated C.P. bottle trap JAQUAR(ESSCO)-ALE-733ML 190X125 with cleaning eye with extension piece and wall flange,Painting brackets with two coats of white enamel paint over one coat of primer,CP Basin Faucet JAQUAR(ESSCO)-MQT-508KN with 15 mm C.P. brass heavy grade flexible inlet connection with C.P. nut (minimum length 450 mm) made to measure. (as directed by engineer in charge complete)

4

-

-

... More
Supply, checking, storing & fixing C.P. brass angle valve for basin & Sink MODEL:JAQUAR(ESSCO)-MQT-526KN, of approved quality conforming to IS:8931 as directed by engineer in charge complete for a) 15mm Nominal Bore

4

-

-

... More
Supply, checking, storing & fixing C.P. brass Long Body bib cock MODEL:JAQUAR(ESSCO)-MQT-512KN of approved quality conforming to IS:8931 as directed by engineer in charge complete . a) 15mm Nominal Bore

2

-

-

... More
Supply, checking, storing & fixing of Heavy class S.S. Grating Model No. Chilly-CCT-SFC-127 or Equivalent with Mosquito /Cockroach proof S.S. strainer of approved design by Interiror including setting in floor with cement motor to match with floor finish as per architect requirement suitable for FD (Floor drain) and FT (Floor trap) as directed by engineer in charge complete. Note : Size of trap is vary as per final Product Selection. (Including Shaft floor Drain & Fire Escape Balcony )

7

-

-

... More
Supply, checking, storing & fixing straight/offset type Macfit single body push fit type WC Pan Connector Jaquar-ZPS-WHT-VB01 with factory supplied spring loaded seal guard with integrated single mould sealing fins made of flexible EVA Body, including bush/adaptor for use with CI Pipe as supplied with Pan Connector (For European water closet) as directed by engineer in charge complete

4

-

-

... More
Providing and fixing PVC SWR Pipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc as directed by engineer in charge complete (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 75MM

12

-

-

... More
Providing and fixing PVC SWR Pipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc as directed by engineer in charge complete (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 110MM

22

-

-

... More
Pipes for soil , waste , Rain , Vent for Shaft /External Area of approved make as directed by engineer in charge complete 75MM

6

-

-

... More
Pipes for soil , waste , Rain , Vent for Shaft /External Area of approved make as directed by engineer in charge complete 110MM

26

-

-

... More
Providing and fixing PVC Agri 6Kg/cm2 and fitting for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance,cutting, chases/holes in walls/flors/slab etc. (Pipes to laid in Toilets) as directed by engineer in charge complete (Make:Astral,Ashirvad,Suprime) 50mm

12

-

-

... More
Providing and fixing PVC traps of self cleansing design with water seal not less than 50mm with or without vent, including setting the trap in 1:2:4 cement concrete etc as directed by engineer in charge complete. The trap shall be `P' type as required. Trap with 100 mm inlet and outlet 75mm/100mm dia.(Make:Astral,Ashirvad,Finolex)

2

-

-

... More
Providing and fixing in position Multi Floor Trap/Plain Floor Trap self cleansing design moulded or fabricated with 50 mm water seal conforming to IS:14735-90 including setting the trap in 1:2:4 cement con'crete etc. (Make:Astral,Ashirvad,Finolex) 100mm Outlet

8

-

-

... More
Supply , installation , testing and commissioning rain water Sidewall Parapet CI Body With Aluminium Grate With 4 SS Screw Drains ,size as per drawing required depth with Making Khurra with Proper water proofing and fixing the fittings (Horizontel/vertical arrangment grating) complete as required.(Make:Neer,Weimer) 450x 450 mm as directed by engineer in charge complete (100mm outlet pipe dia )

4

-

-

... More
SOIL WASTE AND VENT PIPE - INTERNAL WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as directed by engineer in charge complete Concealed work, including cutting chases and making good the walls etc. For Hot & Cold Water Lines ( Domestic ) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 15 mm nominal outer dia Pipes ( SDR 11 )

30

-

-

... More
SOIL WASTE AND VENT PIPE - INTERNAL WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as directed by engineer in charge complete Concealed work, including cutting chases and making good the walls etc. For Hot & Cold Water Lines ( Domestic ) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 20 mm nominal outer dia Pipes ( SDR 11 )

12

-

-

... More
SOIL WASTE AND VENT PIPE - INTERNAL WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as directed by engineer in charge complete Concealed work, including cutting chases and making good the walls etc. For Hot & Cold Water Lines ( Domestic ) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 25 mm nominal outer dia Pipes ( SDR 11 )

12

-

-

... More
SOIL WASTE AND VENT PIPE - INTERNAL WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as directed by engineer in charge complete Concealed work, including cutting chases and making good the walls etc. For Hot & Cold Water Lines ( Domestic ) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 32 mm nominal outer dia Pipes ( SDR 11 )

12

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as directed by engineer in charge complete For Hot & Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) 40 mm nominal outer dia Pipes ( SDR 11 )

12

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as directed by engineer in charge complete For Hot & Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) 50 mm nominal outer dia Pipes ( SDR 11 )

12

-

-

... More
Providing, fixing and testing of heavy quality CPVC BALL Valves of 15 Kg / sqcm pressure with all necessary unions and nipple collars fixing on CPVC lines as directed by engineer in charge complete (Make:Astral,Ahirvad,Finolex) 32mm dia

2

-

-

... More
Providing, fixing and testing of heavy quality CPVC BALL Valves of 15 Kg / sqcm pressure with all necessary unions and nipple collars fixing on CPVC lines as directed by engineer in charge complete (Make:Astral,Ahirvad,Finolex) 50mm dia

2

-

-

... More
EXTERNAL WATER SUPPLY,DRAINAGE AND STORM WATER Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints as directed by engineer in charge complete (C) 250mm (upto 10 ton)

9

-

-

... More
Providing, laying, jointing and testing heavy quality DWC (Double wall Corrugated ) under ground application pipes for Sewer and strom line with Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed by engineer in charge complete incl. 150 mm dia

12

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design and as directed by engineer in charge complete b)150 mm dia diameter

12

-

-

... More
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight as directed by engineer in charge complete.(i) Square mouth traps. (A) 100mm x 100mm size P type. (upto 10 ton)

2

-

-

... More
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 800mm and 0.9M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) as directed by engineer in charge complete (1) A type depth 0.90 Metre for 150mm diameter sewer.

1

-

-

... More
(I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No.81 as directed by engineer in charge complete (I) for depth from 0.9M to 1.5M.

2

-

-

... More
Providing and fixing cast iron steps of size 500mm x 150mm x 22.5mm and painting with two coats of Anti-corrosive paint etc. as directed by engineer in charge complete

20

-

-

... More
Supply, installation, testing & commissioning of Submersible single stage single entry pumps connected to submersible motor (The motor shall be IE3 watertight according to IEC class IP 68, and incorporate class F, insulation materials to withstand a continuous operating temperature of 155 deg C) for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit Or Auto Coupling with rubber diaphragm and bend, vertical discharge pipe,Starter Panel IP65 Outdoor Type. The pump shall be provided with a lifting devise of pull chain/guide rail & G.I. heavy class rising main of 5m length including interconnecting piping, valves (Ball Valve / Butterfly), Non return valves (GM/CI) 15 m cable etc.High level and low level sensor with motorized butterfly valve as per requirement complete in all respects as directed by Engineer-in-charge. (Pumps shall be installed in a set of two pumps One working and One standby, with cascade operation). For supplying Domestic Water up to terrace Capacity per pump - 180 LPM Head - 30 mtr 1 Set = 2 Nos. Pump (1 Working + 1 Standby - cascade operation) Suction head - flooded positive suction Supply, Installation, testing & commissioning (Make:Kriloskar,Lubi)

1

-

-

... More
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board having IP-64 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection, supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. (The rates includes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufacturers as per attached SLD - MAIN LT Panel (160A FP MCCB WITH ELR AS INCOMER AND 25 Nos X 32A DP MCB AS OUT GOING with RYB ON-OFF-Trip Lamps and Multi function meter with CT or as directed by engineer in charge complete

1

-

-

... More
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs as directed by engineer in charge complete. (The DBs should be used of same company of MCB to be used) - (H) Single phase 12 way SS Double door

1

-

-

... More
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs as directed by engineer in charge complete.(The DBs should be used of same company of MCB to be used) - (E) Single phase 8 way single door

23

-

-

... More
Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark as directed by engineer in charge complete - SP MCB

100

-

-

... More
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity as directed by engineer in charge complete 6 to 32 Amp. - DP MCB

24

-

-

... More
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed by engineer in charge complete 25 Amps.DP

24

-

-

... More
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed by engineer in charge complete 40 Amps.DP

1

-

-

... More
Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB. - Double Pole / Four Pole as directed by engineer in charge complete

24

-

-

... More
1.2KV Protection level DP, Class 's', (Imax-15KA, 8/20µS) LEGRAND Cat no. 3941 or Equivalent as directed by engineer in charge complete

1

-

-

... More
Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be erected as per IS or as directed by engineer in charge complete

28

-

-

... More
Providing and erecting metallic vitrified danger notice board for HIGH VOLTAGE installation to be erected as per IS or as directed by engineer in charge complete

4

-

-

... More
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed by engineer in charge complete

1

-

-

... More
Providing and erecting approved make light control unit suitable to operate on 230V +20% having ON/OFF delay time of 30-50 seconds and having facility for Auto/manual system having two LDR lens to intensity light having capacity of 5A complete erected on section pillar with pipe and stand. Supplying & erecting power contactor for time switch complete erected (as directed by engineer in charge complete) Cat III 4 pole 440V 40 Amp.

2

-

-

... More
Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making the surface as normal ground as directed by engineer in charge complete

30

-

-

... More
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable as directed by engineer in charge complete (16 bricks per meter)

75

-

-

... More
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables as directed by engineer in charge complete. (a) 4 core 2.5 Sq. mm

80

-

-

... More
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables as directed by engineer in charge complete. (a-1) 4 core 4 Sq. mm

920

-

-

... More
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables as directed by engineer in charge complete. (B) 4 core 6 Sq. mm

50

-

-

... More
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables as directed by engineer in charge complete (E) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)

75

-

-

... More
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables as directed by engineer in charge complete Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 4 core 4 Sq. mm / 4 core 2.5 Sq. mm

64

-

-

... More
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables as directed by engineer in charge complete. Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 4 core 6 Sq. mm

4

-

-

... More
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables as directed by engineer in charge complete. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 3 & 1/2 core 120 Sq. mm

4

-

-

... More
Supplying & laying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water having following size of dimensions and No of compartments (W x D x T) : 150mm x 38mm x 1.6mm with Three Compartments

10

-

-

... More
[C] G.I. Junction cross over box for metal / Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size as directed by engineer in charge complete.150mm x 150mm x 60/75 mm depth

10

-

-

... More
[C] G.I. Junction cross over box for metal / Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size as directed by engineer in charge complete.300mm x 300mm x 60/75 mm depth

2

-

-

... More
Supplying and erecting approved make GRP Perforated type Cable Tray as directed by engineer in charge complete Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % - - Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (D) Width - 150mm, Pultruded “C” Channel with 30mm Sides 3mm Thickness, Loading 15 Kg./Mtr.

10

-

-

... More
(E) Width - 200mm, Pultruded “C” Channel with 40mm Sides 4mm Thickness, Loading 25 Kg./Mtr.

10

-

-

... More
Fabrication : Supplying , fabricating and installation of various sizes clamps for cable tray supports using available M.S. sections & rod as per drawings or as directed by engineer in charge complete or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc.

50

-

-

... More
HEAT / FIRE RESISTANT COATING OF CABLE Supply and application of intumescent based coating on cables/ cable tray using CP 678 firestop cable coating of HILTI make or equivalent as directed by engineer in charge complete. The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. The coating shall comply with IEC 332 part 3 (1992).

30

-

-

... More
Point wiring for Light Point / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed by engineer in charge complete with medium class Rigid PVC pipe and accessories

120

-

-

... More
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories as directed by engineer in charge complete Wire : (a) 2 wire 1.5 sq. mm

615

-

-

... More
Additional Wire : Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size as directed by engineer in charge complete in (a) with medium class Rigid PVC pipe and accessories Wire : (b) 2 wire 2.5 sq. mm

360

-

-

... More
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling, complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connectoras directed by engineer in charge complete (a) with medium class Rigid PVC pipe and accessories

45

-

-

... More
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed by engineer in charge complete (a) with medium class Rigid PVC pipe and accessories

10

-

-

... More
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed by engineer in charge complete (a) with medium class Rigid PVC pipe and accessories

25

-

-

... More
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as directed by engineer in charge complete

100

-

-

... More
Do - As - Above but for 6 A x 5 pin 250 Volt switched socket outlet point at convenient location as directed by engineer in charge complete ( Plug & Switch can be together or at different location )

100

-

-

... More
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories as directed by engineer in charge complete [II] For 6/16A Plug with 2-2.5 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories

5

-

-

... More
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories as directed by engineer in charge complete [III] For 16A Plug with 2-4 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories

30

-

-

... More
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling as directed by engineer in charge complete Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness

200

-

-

... More
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling as directed by engineer in charge complete Supply and laying of 32 mm rigid PVC pipe of 1.6-1.8 mm thickness

60

-

-

... More
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling as directed by engineer in charge complete Supply and laying of 40 mm rigid PVC pipe of 1.6-1.8 mm thickness

30

-

-

... More
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr as directed by engineer in charge complete (B) 50 mm Dia. (2.5Kg/6RMT)

20

-

-

... More
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr as directed by engineer in charge complete (D) 75 mm Dia (5.5 Kg / 6RMT)

50

-

-

... More
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr as directed by engineer in charge complete (E) 90 mm Dia (8.0 Kg / 6RMT)

20

-

-

... More
Supplying & erecting Electronic Type Cordless Call Bell erected on PVC/Metal board having portable bell push working on D.C. & bell on 230V A.C. supply with cells / battery as directed by engineer in charge complete

2

-

-

... More
Computer : Power Plugs 1 no. universal plug-switch combined + 1 Nos swithc for Below table 2 nos. 6A 5 pin Plug as below Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories Cat. III as directed by engineer in charge complete + Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories as directed by engineer in charge complete. [I] For 6A Plug with 2-1.5 sq.mm Cu. Wire (Car.iii) + [II] For 16A Plug with 2-2.5 sq.mm Cu. Wire (Car.iii)

1

-

-

... More
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size as directed by engineer in charge complete : 4 wire 4 sq. mm

140

-

-

... More
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size as directed by engineer in charge complete : 4 wire 6 sq. mm

20

-

-

... More
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size as directed by engineer in charge complete: 4 wire 10 sq. mm

10

-

-

... More
Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy & 30 cms. down rod erected with 24/0.2, 3 core flexible wire with earthing. It should be BLDC motor -5, 320RPM, 30-35W 5-Star rating Power saving Fan as directed by engineer in charge complete

25

-

-

... More
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing as directed by engineer in charge complete.

5

-

-

... More
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM as directed by engineer in charge complete [C] 380 mm dia 1400 RPM

5

-

-

... More
Supply,installation, testing and commisioning of Internal light fixtures of 1200mm long LED Tube light (20W) with 110LPW white color Aluminum extruded body and milky white diffuseras directed by engineer in charge complete .Make : Trilux, Wipro, Philips

65

-

-

... More
Supply,installation, testing and commisioning of IP-65 Surface Mounted 16W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp with inbuilt driver and driver. LUMEN EFFICACY 110lm/w, PF 0.90, THD 20%, CCT 6000K as directed by engineer in charge complete, Make : Trilux, Wipro, Philips

35

-

-

... More
Supply,installation, testing and commisioning of IP-65 DRIVER HANDING TYPE 35-50W LED HANGING LIGHT with White Aluminum dia cast, powder coated housing, reflector, with LED lamp with inbuilt driver and driver. LUMEN EFFICACY 110lm/w, PF 0.90, THD 20%, CCT 6000K as directed by engineer in charge complete, Make : Trilux, Wipro, Philips, Tucana

10

-

-

... More
Supply,installation, testing and commisioning of Wall Mounted IP-65 2x6W LED up-down light with die cast construction, Double reflector, toughened glass cover with LED lamp and driver.-PF0.9 ,THD 20% as directed by engineer in charge complete ,Make : Trilux, Wipro, Philips

15

-

-

... More
Supply,installation, testing and commisioning of 20W LED WALL WASHER LIGHT WITH ip-67 /IK 07protection, Aluminum dia cast BODY, 15'/55' LENSE DIFFUSER, LUMEN EFFICACY 90lm/W, PF 0.90, THD 20%, CCT 4000K, powder coated adjustable housing, with LED Panel and driver as directed by engineer in charge complete.Make : Trilux, Wipro, Philips

30

-

-

... More
Supply,installation, testing and commisioning of IP-65 3-6W LED Spike light with die cast aluminum 300 mm long spike, powder coated housing, reflector, toughened glass cover with LED lamp and driver as directed by engineer in charge complete. Make : Trilux, Wipro, Philips

10

-

-

... More
Supply,installation, testing and commisioning of IP-65 35-40W LED Each LED Lmap Post made up of die cast aluminum, powder coated IP-65 housing, reflector, toughened glass cover with LED lamp and driversuitable for mounting on 3.0 Mtr FRP Light Pole as directed by engineer in charge complete. Make : Trilux, Wipro, Philips, K-Lite

4

-

-

... More
Supply of approved make GRP / FRP Pole having following specifications: GRP Light Pole made by CNC filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass content. The pole should be in one piece and tapered round in shape, having smooth finish and should be totally free from corrosion as well as non conductive & shock proof Pole should be provided with FRP Anchor Base and it should be heavy duty, or MS Material duly painted with Epoxy paint as directed by engineer in charge complete Pole should be flame retardant as per IS 6746. Resin used shall be UV resistance and pigmented. A highly weather resistant polyurethane coating shall be applied to the pole after applying suitable primer system that ensures proper adhesion of the paint. Minimum coating thickness shall be 80 to 100 micron. Deflection of the pole shall not exceed more than 10% of the length of pole for the given load“? Pole should be generally made as per the dimensional data, performance criteria and some interchangeability features of poles as per standard ANSI C 136.20 latest version or ASTM D 4923/01. The size of pole and type of installation are as below . [B] Overall length of 3 Mtr Average Thickness: 7mm. Top/ Bottom OD Dia A/F 89/130mm ± 2mm approx. Weight of Pole: 12 kg apporx. (Without Base) Anchor Base (Size 250X250 & 12mm th.)

4

-

-

... More
Providing M-20 / 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cms. Deep in below ground level with plinth of 45 cms x 45 cms (or 45 cms dia x 45 cms) high upper ground level with necessary curing and finishing as directed by engineer in charge complete. ( for 4 & 6 mtr pole)

4

-

-

... More
Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 2mm thick box complete with bakelite connector strip 4way & hinged doors having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box as directed by engineer in charge complete.: (b) 250mm x 200mm x 100mm [deep]

4

-

-

... More
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil as directed by engineer in charge complete Length of Pipe : 3.00 mtrs Back filling Compound :2 nos Bags of 25 Kg.

4

-

-

... More
Supplying & erecting of Conventional Lightening arrestor with Test loop and Counter as per IS standard and as directed by engineer in charge complete

1

-

-

... More
Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp as directed by engineer in charge complete

80

-

-

... More
Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG as directed by engineer in charge complete

35

-

-

... More
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling as directed by engineer in charge complete Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .

1380

-

-

... More
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection as directed by engineer in charge complete (8) Modem Jack for Computer Open RJ-45 - cat-III

5

-

-

... More
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection as directed by engineer in charge complete (3) Two Pin/RJ-11 Telephone Socket for One Gong Bell - cat-iii

30

-

-

... More
Supplying & erecting Push button type telephone instrument as directed by engineer in charge complete (A)BEETEL Secure / BPL/, SONY / PANASONIC or equivalent make

30

-

-

... More
Supplying & erecting approved make LAN cable of following size in existing pipe as directed by engineer in charge complete : [C] CAT - 6

1225

-

-

... More
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections as directed by engineer in charge complete (b) Armoured [Jelly Filled] - 10 Pair

60

-

-

... More
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation as directed by engineer in charge complete RG-6 Cable

120

-

-

... More
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation as directed by engineer in charge complete RG-11 Cable

60

-

-

... More
Supply, Installation, Testing and Commissioning of 5 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Indoor IR Eyeball, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR, DWDR, 3.6mm lens, 4 IN 1 as directed by engineer in charge complete

16

-

-

... More
Supply, Installation, Testing & Commissioning of 2 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Outdoor IR Bullet, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR, DWDR, IP66, 3.6mm lens, 4 IN 1 OUTPUT as directed by engineer in charge complete

8

-

-

... More
Supply, Installation, Testing and Commissioning of 16-Channel Digital Video Recorder recording with 4TB HDD with all require installation and integration with all camera system, 16 Turbo HD input, 16-ch video&1-ch audio input, 2 SATA interface, 1280×720P: 25(P)/30(N) fps/ch, 380 1U caseW/O HDD with all require software as directed by engineer in charge complete

1

-

-

... More
Supply, Installation, Testing and Commissioning of 8-Channel Digital Video Recorder recording with 4TB HDD with all require installation and integration with all camera system, 8 Turbo HD input, 8-ch video&1-ch audio input, 2 SATA interface, 1280×720P: 25(P)/30(N) fps/ch, 380 1U caseW/O HDD with all require software as directed by engineer in charge complete

1

-

-

... More
Installation, Testing and Commissioning of 32" Full HD LED monitor with Power Cord complete as required & necessary video cards as directed by engineer in charge complete (if required). Make - Sony, Samsung, Philips

1

-

-

... More
Supply, Installation, Testing and Commissioning Power Supply for Camera as directed by engineer in charge complete

8

-

-

... More
Supply, Installation, Testing and Commissioning CCTV cable in 25mm dia PVC Pipe 3+1 Camera Cable as directed by engineer in charge complete

680

-

-

... More
Supply installation testing and commissioning High Speed quick power charging station for Electrical vehicle as per standard voltage rating with 40A FP MCB and 2 Nos 6A power plugs, it should have digital screen and all parameter recorders as directed by engineer in charge complete

2

-

-

... More
Supply installation testing and commissioning of roof top solar system with 20 years performance warranty , cost include high efficiency solar SPV module, require earthing, Lightening arrestor, supporting fabrication hot dip GI structure with paint, all require wiring, ACDB DCDB, Solar power meter, and inverter as require with consideration of 1-Year DLP (1KW Each) as directed by engineer in charge complete

5

-

-

... More
AMC : Comprehensive AMC with performance gurantee for the Installed Solar Panel for 1st Year after DLP (period 3% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc as directed by engineer in charge complete

1

-

-

... More
AMC : Comprehensive AMC with [erformance gurantee for the Installed Solar Panel for 2nd Year after DLP (period 3.5% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc as directed by engineer in charge complete

1

-

-

... More
AMC : Comprehensive AMC with [erformance gurantee for the Installed Solar Panel for 3rd Year after DLP (period 4% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc as directed by engineer in charge complete

1

-

-

... More
Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 1st Year (as directed by engineer in charge complete) Scope of work to Operate & maintnance of the following Work Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, AC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone, CCTV network and Equiment etc

12

-

-

... More
Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 2nd Year (as directed by engineer in charge complete) Scope of work to Operate & maintnance of the following Work Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, AC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone, CCTV network and Equiment etc

12

-

-

... More
Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 3rd Year (as directed by engineer in charge complete) Scope of work to Operate & maintnance of the following Work Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, AC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone, CCTV network and Equiment etc

12

-

-

... More
Supplyinhg certified, trained 2+Year Experienced Electrician man-power for the Monthly Basis for 4th Year (as directed by engineer in charge complete) Scope of work to Operate & maintnance of the following Work Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, AC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone, CCTV network and Equiment etc complete as directed by Engineer-in -charge.

12

-

-

... More
Liaoning with Local Electricity Board & Electrical Inspector for upgradation of Existing 11KV HT Power & Electrical inspector certification in totality to charge the power other related accessories. etc. as directed by engineer in charge complete Charges for doing liasioning work for obtaining the necessary clearances from the Electrical inspector/competent Authorities for the total Electrical installation, Elevator Inspection, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by the seauthorities shall be prepared and furnished by the EPCV endor. Any modification / rectification as required by these authorities shall be carried out by the EPCV endor at free of cost. The fees required to be paid to these authorities for inspection shall be borne by Owner on production of documentary evidences.

1

-

-

... More
Liaoning with local authority / Fire Dept for roof top solar system (as directed by engineer in charge complete) Charges for doing liasioning work for obtaining the necessary clearances from the Electrical inspector/competent Authorities for the total Electrical installation, Elevator Inspection, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by the seauthorities shall be prepared and furnished by the EPCV endor. Any modification / rectification as required by these authorities shall be carried out by the EPCV endor at free of cost. The fees required to be paid to these authorities for inspection shall be borne by Owner on production of documentary evidences.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.