Military Engineer Services Tender
View complete overview of Daman & Diu MES Tender
Military Engineer Services - MES Tender
Housekeeping Services
Eprocure
Opening Date20 Dec 2024
Closing Date10 Jan 2025
Tender AmountRefer Documents
Costs
EMD
₹ 28,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689641_1Tender No
8842/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles etc complete all as specified and directed.
2
-
-
... More
Demolition of Plain cement concrete (unreinforced) n exc 15cm thick but below or above ground level etc complete all as specified and directed.
1
-
-
... More
Demolition of reinforcement cement concerete as cover slab all as specified and directed.
3
-
-
... More
M&L for cement concrete 1:3:6 Type C-2 (40 mm graded aggregate ) 100mm thick and finishing the cement concrete even and smooth without using extra cement etc complete all as specified and directed.
15
-
-
... More
M&L for precast reinforced cement concrete PCC 1:2:4 type B-1 (20 mm graded aggregate) as in manhole/drain cover slabs etc set in CM 1:4 including use and waste of formwork and finishing top surface of cover slab even and smooth using extra cement etc complete all as specified and directed. (Note : Steel reinforcement shall be measured and paid separately)
4
-
-
... More
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking hooking ends and binding with and including MS wire annealed not less than 0.9mm dia complete all as specified and directed.
150
-
-
... More
M & L for excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out soft loose soil complete all as specified and as directed.
10
-
-
... More
M&L for Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in foundation filling and mass concrete.
2
-
-
... More
M&L for brick work with sub class 'B' old sized bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 as in man holes etc complete all as specified and directed.
4
-
-
... More
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in surface channels in manholes etc complete all as specified and directed.
1
-
-
... More
M&L for PCC 1:2:4 type -B1 using 20mm graded aggregate as in coping with and inclusive of form work as required etc complete all as specified and directed.
1
-
-
... More
M&L for rendering 10 mm thick in CM 1:4, on fair faces of brick work or concrete surface, finished even and smooth without using extra cement, complete all as specified and directed.
14
-
-
... More
M&L for demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM (Internal dia of pipe 150 mm)
20
-
-
... More
M&L for demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM (Internal dia of pipe 200 mm)
20
-
-
... More
M & L for concrete bed to drain pipes including forming cradles in cement concrete 1:3:6, type C 2 (using 40 mm graded stone agg.) for bore of pipe 150 mm all as specified and as directed.
20
-
-
... More
M & L for concrete bed to drain pipes including forming cradles in cement concrete 1:3:6, type C 2 (using 40 mm graded stone agg.) for bore of pipe 200 mm all as specified and as directed.
20
-
-
... More
M&L for 150 mm dia reinforced concrete pipes class NP2 laid and jointed with collars complete all as specified and directed.
20
-
-
... More
M&L for 200 mm dia reinforced concrete pipes class NP2 laid and jointed with collars complete all as specified and directed.
20
-
-
... More
Disamantling of cast iron pipes of any description with fittings fixed to walls or laid in floors/trenches.
30
-
-
... More
S&F Cast iron (spun pipes) soil, waste and vent pipes 100mm bore in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed.
4
-
-
... More
S&F 100mm bore of pipe Bends (any radius), diminishing pieces or
tapers (larger bore measured) with oval access door etc complete all as specified and directed.
2
-
-
... More
S&F 100mm bore Sockets (double) collars for CI pipe etc complete all as specified and directed.
1
-
-
... More
S&F 100mm CI vent cowl all as specified and directed.
2
-
-
... More
S&F 100mm bore Branch pieces, single (equal or unequal),ordinary or inverted (spigot or socket type) or with parallel branches for CI pipes fitted with oval access door etc complete all as specified and directed.
1
-
-
... More
S&F PVC (SWR) pipes 110mm bore single socketed, in any length and any description with rubber ring joints fixed to walls etc all as specified and directed.
10
-
-
... More
S&F PVC (SWR) pipes 110mm bore single socketed, in any length and any description with rubber ring joints laid in trenches or in floors etc all as specified and directed.
10
-
-
... More
S&F 110mm bore of pipe PVC (SWR Grade) bends with access door of any radius all as specified and directed.
2
-
-
... More
S&F 110mm bore of pipe PVC (SWR) branch piece, single (single Y) equal or unequal with access door of any radius all as specified and directed.
1
-
-
... More
S&F 110mm PVC (SWR) vent cowl all as specified and directed.
3
-
-
... More
S&F 75mm dia PVC (SWR) grade pipes single socketed in any length including fixing clips/ruuber joints laid in trenches or in floors etc complete all as specified and as directed.
3
-
-
... More
S&F 75mm dia PVC (SWR) grade pipes single socketed in any length including fixing clips/ruuber joints fixed to walls etc complete all as specified and as directed.
5
-
-
... More
S&F PVC SWR grade bends of any radius with inspection door 75mm bore of pipe complete all as specified and as directed.
3
-
-
... More
S&F 75mm bore of pipe PVC (SWR) branch piece, single (single Y) equal or unequal with access door of any radius all as specified and directed.
1
-
-
... More
S&F 75mm PVC (SWR) vent cowl all as specified and directed.
2
-
-
... More
S & F in repairs PVC SWR floor trap with CP grating 75 mm dia of outlet including jointing with solvent cement etc complete all as specified and directed.
3
-
-
... More
M&L for returning filling in foundation trenches with available soil spread and levelled in layers n exc 25cm thick watered and well rammed to a true surface, complete all as specified and directed.
5
-
-
... More
M&L for removal of surplus excavated soil to a distance exc 1.50 Km and depositing outside MD land etc complete all as specified and directed.
2
-
-
... More
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching internal dia of pipe 150mm etc complete all as specified and directed.
3
-
-
... More
De-sludging/De-silting of 500 user septic tank including filter bed by bailing out fluid, decomposed materials sludge etc outside MD land complete all as directed by Engineer-in-charge. Note 1. Sludege/de-composed materials obtained from cleaning shall be removed outside MD land by mechanical sewage cleaning tanks and disposed off to designated places as ear marked by local bodies. Note 2. Rate inclusive of clearing away all grass vegetation, saplings shrubs and trees not exceeding 30cm girth upto 3 mtrs alround the septic tank and removing rubbish upto a distance 50mtrs outside the periphery area.
3
-
-
... More
All as per item No.01, but 150 user septic tank
3
-
-
... More
All as per item No.01, but 100 user septic tank
5
-
-
... More
All as per item No.01, but 50 user septic tank
6
-
-
... More
All as per item No.01, but 25 user septic tank
5
-
-
... More
All as per item No.01, but 10 user septic tank
12
-
-
... More
Cleaning/clearing blockage of soakge well at any depth and any width fully functional by suitable material like loose filling broken bricks, sand , aggregate etc complete. Note:- Each job shall be carried out in a requirement basis as specified and directed by Engineer-in-charge.
12
-
-
... More
M&L for loose filling with broken bricks in soakage pits, soakage wells .
18
-
-
... More
M&L for demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles etc complete all as specified and directed.
5
-
-
... More
M&L for brick work with sub class 'B' old sized bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 as in man holes etc complete all as specified and directed.
5
-
-
... More
M&L for rendering 10 mm thick in CM 1:4, on fair faces of brick work or concrete surface, finished even and smooth without using extra cement, complete all as specified and directed.
60
-
-
... More
Demolition of Plain cement concrete (reinforced) n exc 15cm thick but below or above ground level etc complete all as specified and directed.
2
-
-
... More
M&L for Reinforced cement concrete type B1 ( 1:2:4 ) 20 mm graded stone aggregate on Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
2
-
-
... More
S& F Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick all as specifid and dirceted.
(Horizontal or sloping)
20
-
-
... More
Demolition of reinforcement cement concerete as cover slab all as specified and directed.
5
-
-
... More
M&L for precast reinforced cement concrete PCC 1:2:4 type B-1 (20 mm graded aggregate) as in manhole/drain cover slabs etc set in CM 1:4 including use and waste of formwork and finishing top surface of cover slab even and smooth using extra cement etc complete all as specified and directed. (Note : Steel reinforcement shall be measured and paid separately)
7.65
-
-
... More
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking hooking ends and binding with and including MS wire annealed not less than 0.9mm dia complete all as specified and directed.
580
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%