UT Administration Of Dadra And Nagar Haveli Tender

View complete overview of Dadra & Nagar Haveli UT Administration Of Dadra And Nagar Haveli Tender

UT Administration Of Dadra And Nagar Haveli Tender

Consultancy Services
Eprocure
Opening Date17 Jul 2021
Closing Date13 Sep 2021
Tender Amount₹ 5,60,83,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Scope and Technical Specification For Road Works
Scope and Technical Specification for Water supply
Scope and Technical Specification For Sewerage Works
Condition of Contract for O and M (Water)
Condition of Contract for O and M (Sewerage)
Financial Schedule - B
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing asphalt courses by milling machince in layers including transporting the removed materials outside the MbPT Estates complete as directed. A) For milling depth upto 55mm B) For subsequent each 5mm depth As per Mumbai Port Trust SOR-2011 Item No.50 Page No-63

205842.4

-

-

... More
Box cutting the Road surface to proper slope and camber for making a base for road work incl. removing the excavated stuff and depositing on the road side slope us directed upto 50 Mt.lead.

169402.5

-

-

... More
Carriage of earth.3 km or as directed by Engineer incharge (upto 10 ton)

169311

-

-

... More
Earth work in embankment including breaking clods,dressing with rolling and consolidation of subgrade in layers at OMC to required dry density incl. filing the depression which occur during the process of power roller of 8 to10 T brought from outside etc.complete as directed by engineer in charge. (With CBR more than 8%)

60284

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate material in sub base course including mixing in a mechanical mix plant at OMC , carriage of mix material, spreading in uniform layers with motor grader for sub base including spreading of stone dust to fill up voids on the surface and watering compacting with vibratory roller to achieve CBR value not less than 30 as per MORTH and the desired density (as per designed mix determined density) including all materials, labour, machinery.etc completed.

43454.4

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate material in sub base course including mixing in a mechanical mix plant at OMC , carriage of mix material, spreading in uniform layers with motor grader for sub base including spreading of stone dust to fill up voids on the surface and watering compacting with vibratory roller to achieve CBR value not less than 30 as per MORTH and the desired density (as per designed mix determined density) including all materials, labour, machinery.etc completed.

95536.2

-

-

... More
Tack Coat :Providing & applying evenly Priming Tack Coat on WMM surface with Emulsion RS1 @ 9/10 m2 including coat asphalt heating and the cost of spraying unformly complete as directed.

540734.9

-

-

... More
Providing & laying compacted thick dense graded bituminous macadam (DBM) Grade-2 in Single layer using 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour, tack coat(VG-40) at the rate of 2.5 kg / 10 m2 in each using crushed aggregates of specified grading . premixed with bituminous content @ 4.5% (VG-40) by weight of total mix and filler , transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control with minimum road width or as directed by Engineer in charge to the required grade, level and alignment, rolling with smooth wheeled vibratory and tandem rollers to acheive the desired compaction as per MORT&H specification etc complete in all respects. The agency shall have to get the mix design done from approved laboratory and submit to the Engineer in charge for approval. If the asphalt (bituminous) content is more than above, the agency shall have to bear the cost of additional asphalt. The payment shall be done on the permissible field density achieved on the site instead of density derieved in the mix design. ( Assume density = 2.40gms/cm3)

92620.2

-

-

... More
Providing and laying Bituminous Concrete using crushed stone aggregate BT chips as per required gradation and using VG-40 as a tack coat @ 2.5 kg / 10 sq.m and the VG-40 grade asphalt at 5.40 % (i.e. 54 kg/MT) by total weight of mix hot laid process using TPH batch mix type plant including heating and mixing asphalt & materials by batch mix process transporting the mix and laying by hydrostatic paver finisher including consolidation with vibratory roller & PTR including cost of material labour machinary equipment and fuel, oil. Lubricant for plant and machinary using contractor's own plant and machinanes etc complete. The agency shall have to get the mix design done from approved laboratory and submit to the Engineer in charge for approval. If the asphalt (bituminous) content is more than above, the agency shall have to bear the cost of additional asphalt. The payment shall be done on the permissible field density achieved on the site instead of density derieved in the mix design. [Assume Density=2.45 gms/cm3]

52129.2

-

-

... More
Bituminous Paint: Applying bituminous paint VG-40 @ 6 kg / 10 sq.mt incl heating the bitumen and sparying by tanker etc completed

530413.9

-

-

... More
Providing and laying of Hot applied Thermoplastic compound 2.5 mm thick including Reflectorising Glass Beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC : 35 & finished surface to be level, uniform and free from streaks and holes. (As per Government letter No.SOR 102003/94/S-1/ Dated.20-7-2004)

47074.1

-

-

... More
For locking paverblocks:Providing and cast in situ C.C. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete

436.1

-

-

... More
Cautionary Warning Sign :-Providing and fixing sing boards made out of 2mm aluminium sheet; size 90 x 90 x 90 cms. equilateral triangle as per design of IRC-67-1977. Pre treated with phospheting process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint ;reflectorised with retro refiectivesheeting as per latest M.O.S.T.Specifications; 3.1m long stand postand frame fabricated from suitable sizeiron angle of 35 x 35 x 3mm, 75 x 75 x 6mm as required; painted with bestquality epoxy coatings in black andwhite bends. The details of symbol foreach board shall be as per theinstruction of engineer in charge. The fixing at site shall be in 1:2:4 CC blockof size 45 x 45 x 60 Cms. for each leg.including excavation, curing etc.complete under the supervision of engineer in charge.(B) High Intensity Grade..

842

-

-

... More
Regulatory/Mandatory signs :Providing and fixing sing boards made out of 2mm aluminium sheet; size 60cms. diameter circle as per the design of IRC-67-1977 pre treated with phospheting process & acid eteching; coated with one coat of epoxy primer and two coats of best quality epoxy paint; reflectorised with retro refiective sheeting as per latest M.O.S.T. Specifications; 3.1m long stand post and frame fabricated from suitable size iron angle of 35 x 35 x 3mm 75x75x6mm as required; painted with best quality epoxy coatings in black and white bends. the details of symbol for each board shall be as per the instruction of engineer in charge. The fixing at site shall be in 1:2:4 CC block of size 45 x 45 x 60cms. for each leg. including excavation curing etc. complete under the supervision of engineer in charge.(B)High Intensity Grade ...

394

-

-

... More
Informatory Signs :-Providing and fixing sing boards made out of 2mm aluminium sheet; size 80 x 60cms. rectangle as per the design of IRC-67-1977 pre treated with phospheting process & acid teching; coated with one coat of epoxyprimer and two coats of best qualityepoxy paint; reflectorised with retro refiective sheeting as per latest M.O.S.T. Specifications; 3.1m long stand postand frame fabricated from suitable sizeiron angle of 35 x 35 x 3mm75x75x6mm as required; painted with best qualityepoxy coatings in black and whitebends. the details of symbol for eachboard shall details of symbol for eachboard shall be as per the instruction ofengineer in charge. The fixing at site shall be in 1:2:4 CC block of size 45 x45 x 60cms. for each leg. including excavation curing tec. complete under the supervision of engineer in charge.(B) High Intensity Grade.

147

-

-

... More
Parking Signs :-Providing and fixing sing boards made out of 2mm aluminium sheet; size 60 x 60cms. sequare plus 60 x 20cms rectangular additional plate as as per the design of IRC-67-1977 pre treated with phospheting process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint; reflectorised with retro refiective sheeting as per latest M.O.S.T. Specifications; 3.1m long stand post and frame fabricated from suitable size iron angle of 35 x 35 x 3mm 75x75x6mm as required; painted with best quality epoxy coatings in black and white bends. the details of symbol for each board shall be as per the instruction of engineer in charge. The fixing at site shall be in 1:2:4 CC block of size 45 x 45 x 60cms. for each leg. including excavation curing etc. complete under the supervision of engineer in charge.(B)High Intensity Grade ..

16

-

-

... More
Place identification Sign: Provding and Fixing sign boards made out of 2mm aluminium sheet; size 150x90cms. Rectangle as per the design of IRC-67 -1997 pre treated with phospheting process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint; reflectorised with retro reflective sheeting as per latest M.O.S.T Specification; letters and numerals should be as per IRC-30-1968, 3.1m long (2 nos) stand post and frame fabricated from suitable size iron angle of 50x50x5mm 75x75x6mm as required; painted with best quality epoxy coating in black and white bends. the details of symbol or inscription/numerals for each board shall be as per the instruction of engineer in charge. The fixing at the ste shall be in 1:2:4 CC block of size 45X45X60cms. for each leg. including excavation curing etc. complete under the supervision of engineer in charge.(B) (High intensity grades)

177

-

-

... More
Hazard Marker Sign :-Providing and fixing sing boards made out of 2mm aluminium sheet; size 90 x 30cms. rectangle as as per the design/drawing attached (IRC) pretreated with phospheting process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint; reflectorised with retro refiective sheeting as per latest M.O.S.T. Specifications; 3.1m long stand post and frame fabricated from suitable size iron angle of 35 x 35 x 3mm & 50 x 50 x 5mm painted with best quality epoxy coatings The fixing at site shall be in 1:2:4 CC block of size 45x45x 60cms. for each leg. including excavation curing etc. complete under the supervision of engineer in charge.(B)High Intensity Grade ..

152

-

-

... More
Providing and fixing Junction board of M.S. plates and angles as per standard I.R.C. design including fixing in C.C. 1:4:8 with necessary excavation painting figuring and lettering on board etc. complete. C.C. 1:4:8 with necessary excavation painting figuring and lettering on board etc. complete.

36

-

-

... More
Supplying and fixing cat eye (Stimsonite) made out from Acrilo beautile sterine injuction high compressed molding with reflector made of MMC (prismatic type of size 12cm x 6cm x 2.5cm) provided with bituminous adhesive 100g. with each unit for fixing. (High Intensity grade)

34956

-

-

... More
Supplying and installation of Heavy duty Rubberised speed bump 50 to 80 mm high above ground level with fabricated pannels of yellow and black colour of load capacity 60 Tonn of size 400X500X50 mm.

2436.5

-

-

... More
Raising the manhole to the required height (up to road top lvel- RTL), by cleaning the road surface, dismantling the BBM and safely removing the cover and frame,re-constructing the wall with BBM including plaster on both sides and concreting with C.C.1:2:4 up to the required height including re-fixing the frame and cover , curng etc,complete as per the directions of the Enginner-in-charge

2599

-

-

... More
Road painting with Acrylate Based Coloured Slurry Seal on Bituminous Surface (Providing and laying of ShaliSeal® CSS A coloured slurry 1.5 mm thick @ 3.2 kg/sqm area, thickness of 1.5 mm is as directed .The finished surface to be level, uniform and free from streaks and holes.)red height including re-fixing the frame and cover , curng etc,complete as per the directions of the Enginner-in-charge

1887.9

-

-

... More
Patch_work to existing roads- PREMIX CARPET: 20 mm premix carpet surfacing with 1.8 cum and 0.90 cum of stonechippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kgand 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. Including Tack Coat

48300

-

-

... More
Visual Improvement, Landscape, Hard Scape, Beautification Works including Bus Shelter

-

-

-

... More
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense or Hard soil

55772.4

-

-

... More
Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete. (upto 10 ton)

23965.9

-

-

... More
Disposing of available Excavated Stuff up to 5.0km lead including spreading/filling and levelling to gradient camber as directed with all lead and lift and on road side embankment with breaking clods dressing etc. complete as directed by Engineer-in-Charge.

55772.4

-

-

... More
PCC for Tectile, Kerb, Ramp, Cast insitu Kerb:Providing and casting in situ Cement concrete in grade M-15 (approx. corresp. to prop. 1:2:4) (proportions as per mix design or as per Table 9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. complete

11342.7

-

-

... More
Gravel Filling below Paver block-Collecting, carting of unscreened gravel at site of work including spreading in required layers, watering and consolidation the same with vibratory roller etc. complete and as directed by Engineer in charge.

20608.4

-

-

... More
BRICK WORKBrick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(C) Fly Ash Bricks (more than 10 ton)

989.8

-

-

... More
Extra for brick work in superstructure above plinth level upto floor two level(C) Fly Ash Bricks

1061.9

-

-

... More
Kerb Stone: Providing and fixing pre-cast concrete kerb stone of grey cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete. Approved make Vyara,Ace Infracon, Endura, Spectra, Super pre cast or approved by Chief Technical office (CTO).

99859.8

-

-

... More
Providing and casting in situ Cement concrete in grade M-20 (proportions as per mix design or as per table9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding, centering, formwork, needle vibrated consolidation, curing (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. complete for Kerbs/Kerb blocks

1101.9

-

-

... More
Providing, cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for (A) R.C.C. Kerb. (B) R.C.C. Footpath. (C) R.C.C. Approach slab. (D) Wearing Coat for all diameters High yield strength deformed (HYSD) bars/ Cold twisted deformed (CTD) bars confirming to IS1786( latest) Fe – 415 grade

33.1

-

-

... More
Providing and fixing of RCC median wall in M250 grade cement concrete, in Fe-415 steel of minimum thickness of 150mm and overall height of 775mm, including reinforcement steel, shuttering etc complete, as per median section shown on tender drawing and as directed by engineer-in-charge (Note:Median wall not to be designed for impact load.)

14379

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. a) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. Approved make Vyara, Ace Infracon, Endura, Spectra, Super pre cast or approved by Chief Technical office (CTO).

163708.1

-

-

... More
COBBLE STONE:Providing and supply of Granite Cobble Stones of Size: 4”x4”x2 to 3” of color White Grey & Grey with all specifications.Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per sqm over 50mm thick sand bed (average thickness) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of pavar surface joints into its final level, including cost of materials, labour and HOM of machineries complete as per specifications. Makes of: Kataria Cera N Stones or equivalent.

5943.6

-

-

... More
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick (upto 10 ton)

3421.1

-

-

... More
Providing and laying polished kota stone slab 25mm thick in risers of steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (upto 10 ton)

3469.4

-

-

... More
PLASTERING & POINTING20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.

6512.5

-

-

... More
WHITE WASHING COLOR WASHING DISTEMPERING & OTHER FINISHINGFinishing wall with water proofing cement paint of on wall surfaces (Two coats) to give an approved brand and manufacture and of required shape even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials.

41424.5

-

-

... More
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape ven shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc. complete.

378.9

-

-

... More
Applying two coats of Birla (white cement based) or Asian (acrylic lapy- putty) or equivalent & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.

301.5

-

-

... More
TACTILE FLOORING-Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including groutingthe joints with white cement mixed with matching pigments etc.complete as per direction of Engineer-in-Charge.

28034.1

-

-

... More
DEMOLITION & DISMANTLINGDemolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar.

994.7

-

-

... More
Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work

5176.4

-

-

... More
Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

24729.4

-

-

... More
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

38555.6

-

-

... More
Dismentling steel work including distempering and stacking the materials with all lead and lift.

36712.9

-

-

... More
Dismentling barbed wire in fencing including making rolls and also including dismentling fencing posts including all earth work concrete in base and making good the disturbed ground stacking useful materials as directed and disposing as directed and disposing of the unserviceable materials with all lead and lift.

5658.2

-

-

... More
HORTICULTURAL DEVELOPMENT WORK Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).

14562.7

-

-

... More
Labour for Spreading and mixing the manure evenly with top 8 to 10 C.M of Prepared area at the rate of 5 cu.m per 100 sq.m area(Rate for 1 cu.m of manure)

1690.7

-

-

... More
Excavation pits of 60 cm. x 60 cm. x 60 cm. size at specified spots.

36151

-

-

... More
PLANTING TREES AND SHRUBS : After excavating pits of the size 60 cm x 60 cm x 60 cm. refillings the same by providing and mixing Farm Yard Manure at the rate of 0.06 cu.m per pit , providing and planting well grown sapling of specified variety and maintaining till well established. Tree height 2.5 to 3 feet and Shrub height 1.5 to 2.0 feet. Bag size 8'x10' (about 45 days) complete.

36279

-

-

... More
Supplying of Shrub/Creepers/Ficus/Indoor PlantsSupply NERIUM (Karen) of Bag size 7"x8"(Item No-300) - LIGHT PINK FLOWERS

6221

-

-

... More
Supply NERIUM (Karen) of Bag size 7"x8"(Item No-300) - WHITE FLOWERS

5494

-

-

... More
Supply NERIUM (Karen) of Bag size 7"x8"(Item No-300) - DARK PINK FLOWERS

5394

-

-

... More
Supply TABERNAEMONTANA VARIEGATED (Chadni varigated) of Bag size 7"x8"(Item No-307)

4916

-

-

... More
Supply THEVETIA NERIFOLIA (Yellow karen) of Bag size 7"x8"(Item No-309)

8348

-

-

... More
Supply CEASELPHINEA PULCHERIMA (Gultora) of Bag size 7"x8"(Item No-269) - YELLOW FLOWERS

3011

-

-

... More
Supply ALSTONIA SCHOLAIRS (Saptparni)of Bag size 21"x21"(Item No-28)

562

-

-

... More
Supply PLUMERIA ASSORTED VARITIES (Champa) of Bag size 21"x21"(Item No-172) - RUBRA

582

-

-

... More
Supply PLUMERIA ASSORTED VARITIES (Champa) of Bag size 21"x21"(Item No-172) - ALBA

494

-

-

... More
Supply CORDIA SEBESTINA ( Cordia) of Bag size 21"x21"(Item No-79)

383

-

-

... More
Supply TABEBUIA ROSEA ( pentaphylla) of Bag size 21"x21"(Item No-196)

661

-

-

... More
Supply PELTOPHORUM of Bag size 21"x21"(Item No-164)

602

-

-

... More
Maintenance of flowering plants and shrubs in central verge for one year.

14.9

-

-

... More
Providing pure doob (Dharo) Grass Suckers and Planting the same at a distance of 8 to 10 cm.both ways and maintaining the same till well established (about 45 days)(Item No-3)

6582.6

-

-

... More
BENCH-Providing and fixing Precast Glass Fibre Reinforce Concrete bench of 0.45x0.45x 1.3 m lenght of minimum 75 mm thickness, weight 95kg with wooden top with antitermite treatment and varnish with expose smooth concrete finish and weatherproof coating with 8 MPa flexural strenght and compressive strengh of 25 MPa, UV resistant stabilise colour as per Architects choice including fixing, cleaning surfaces and including cost of loding -unloading and placing with crane.The Makes of Benches shall be like Arya Precast,Real Ferro,Concepts Universal, Saflow Products Private Limited, or equivalent or as approved by Chief Technical Officer (CTO).

406

-

-

... More
Tree Grating: SITC of RCC Tree Grates (Light Duty- 5 Tonne) with Perforated Design, Overall Dimensions:800mm (Length) X 800mm (Width) X 75mm, (Thickness), Inner Diameter 300 mm to 600 mm in lacquer/shot blasting finish suitably reinforced with M-25 grade concrete. shape as per requirement. Vyara, UnSons, Tapti or equivalent or as approved by Chief Technical Officer (CTO).

250

-

-

... More
Tree Grating: SITC of RCC Tree Grates (Light Duty- 5 Tonne) with Perforated Design, Overall Dimensions:1100mm (Length) X 1100mm (Width) X 75mm, (Thickness), Inner Diameter 300 mm to 600 mm in lacquer/shot blasting finish suitably reinforced with M-25 grade concrete. shape as per requirement. Vyara, UnSons, Tapti or equivalent or as approved by Chief Technical Officer (CTO).

423

-

-

... More
BOLLARDS-Providing and fixing Bollard of Size 950mm Height with 200mm Dia. with M 20 concrete. with exposed finish, with integrated Colour pigment, shade as specified.

13930

-

-

... More
WASTE BINS-Providing and Fixing Precast Concrete dustbin of 600x600x1000 LBH single cast mono element with terrazzo Texture finish made of Full Depth Terrazzo mix High Performance GlassFiber Reinforced Concrete 12 MPa flexural strength and 40MPa Compressive Strength, UV resistant stabilise colour pigment, colour as per Architects choice including fixing, cleaning surfaces and complete and including cost of loading -unloading and placing with crane. Make shall for Bins Arya Precast,Real Ferro,Concepts Universal, Saflow Products Private Limited, or equivalent or as approved by Chief Technical Officer (CTO).

857

-

-

... More
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone.- Mint sand stone flooring

777.8

-

-

... More
Providing, Applying and finishing the top surface of concrete, in accordance with sprinkling of Uni Stone color hardener at the rate of 0.390 kg. /sq. ft., Floating the surface with different types of floaters, application of release agent at the rate of 0.013 kg. /sq. ft., stamping the concrete with stamping tools, cleaning the surface with water and application of acrylic based sealer for finishing. Complete for parking areas, Compound flooring, Podium, Basement flooring, External roads etc. The rates include labour cost of Stamping and various material used , except concrete.CONCRETE (To be provided by the client) Providing & supplying RMC concrete plain of M30 grade including, curing compound etc. complete.JOINTS Treatment of Construction Joints by Groove cutting of size 4 mm x 20 mm in panel size approximately 3 mtr x 3 mtr as per site.

104.9

-

-

... More
Provisional Cost for Manufacturing of export class FRP sculpture with Metal frame inside. The Sculpture shall have stone finish. Design of the Sculpture shall be as mutually agreed Sculpture description Modern Shell Sculpture Unit per Meter height of scupture Including Installation & Transportation charges.Including Cost of Installation material like Cement, sand, stone chips & labour for the sculpture : 5% of Sculpture cost

13

-

-

... More
Supply and internal fitting of FRP Bio Toilet (4*4*7) with 200 liter FRP Bio Digester Tanl with Indian Commode, 1 Tap, 1 Light Holder

2

-

-

... More
Supply of Water ATM with RO purifier - 2'6"X2'6"X6' - 250 litres/hour water

2

-

-

... More
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.

206.6

-

-

... More
Filling in plinth with sand under floors including watering ramming, consolidating and dressing complete (upto 10 ton)

12.8

-

-

... More
Providing and fixing standared extruded of alluminium section of size63.50 x 38.10 x 1.95 mm(of Jindal Section no:4605, @ Wt 1.094Kg /Rmt with colour anodized alluminium frame with 5 mm thick transparent bronze colour tinted float glass with colour anodized alluminium frame for ventilation with 5 mm thick frosted glass as details etc complete for.window

1.9

-

-

... More
Providing and layingMarbo Grenite tiles 8 to 10 mm thick , 24'' x 24'' in skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry (upto 10 ton)

104.4

-

-

... More
Providing and laying Marbo Grenite tiles 8 to 10 mm thick , 24'' x 24'' in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush pointing in white cement. (upto 10 ton)

24.7

-

-

... More
Providing and fixing FRP frame size 100x50 mm and 28mm thick FRP depress panel shutter having extra reinforcement on sides & edges in Gel coat finish. The core of the shutter & frame is to be filed up with injected fire retardant grade polyurethene foam done in situ alongwith embedded wooden pieces for stiffening & also taking hinges & fintures. The whole FRP frame & shutter is to be water proof weather proof, termite proof & resistance to mild acid/alkali. Rates are to be inclusive of S.S hinges with necessary screws & alluminium fixtures & fastenings & fastener sleeve.

12.2

-

-

... More
Distempeing (Two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on wall surfaces to give an even shade, over and including a priming coat with alkali resistance primer of approved brand after thoroughly brushing the surface and other foreign matter and also including preparing the surface even and sand parpered smooth.

37

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a)First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

25

-

-

... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a)After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b)laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c)third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d)fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.

28.8

-

-

... More
Providing and fixing PVC plain colour false ceiing with grid type with alu frame consisting of 600 mm x 600mm 3mm thick plain PVC sheet used as panel insert in a frame work made using anodized alluminium T section of size 1” x 1” (25 x 25mm, 19 gauge or 1mm thick) in square pattern of grid sizes of 2 x 2 (600 x 600mm). The alluminium frame work is supported from the ceiling with the help of G.I. hook and G.I. wire/6mm M.S. rods of required sizes to maintain proper level etc. The aluminium frame work is supported on side wall with the use of alluminium L section of size 1 x 1 (25 x 25mm) angles et. Complete as per direction of Engineer in charge. Manufactures, specification and drawing

24.7

-

-

... More
Providing upto floor two level precast cement concrete jali or grill 1:2:4 mix (1- Cement: 2- coarse sand : 4-graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia. Mild steel wire including roughening,cleaning, fixing and finishing in cement mortar 1:3 and curing complete. (C) 25mm thick

9

-

-

... More
Cutting of trees, incluging cutting of Trunks, Branches and removal (cutting of trees, including cutting of trunks, branches and removal of stmps, roots, stacking of serviceable material with all lifts and upto lead 1000 mrts and earth filling in the depression/pit) Girth size form 600mm to 900mm

509

-

-

... More
Cutting of trees, incluging cutting of Trunks, Branches and removal (cutting of trees, including cutting of trunks, branches and removal of stmps, roots, stacking of serviceable material with all lifts and upto lead 1000 mrts and earth filling in the depression/pit) Girth size above 1800 mm

47

-

-

... More
Design, fabrication, supply and installation of Stainless Steel (Grade 316) Bus Shelter structure of hollow tubes, channels, plates,roofing ( Polycarbonate Sheet), backing ACP panel or SS Sheet for Advertisement,perforated SS sheet etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary welding stainless steel nuts and bolts, including Twin Bin SS dust bins, Seating Bollards, LED Backlit Advertisement Glow Sign Board of size 1200 mm x 8300 mm , Acrylic Sheet for Route Board, Degital Information board,Mobile charging point and required foundation complete. Size : The Bus Shelter shall be 2.0 m wide x 6.0 m long. Minimum clear headway under it should be 2.2 m.

52

-

-

... More
Design, manufacturing, Supply,  erection, installation, testing and commissioning of Roof top grid tie solar PV power generation plant with standard length of wires of capacity 1 kWp on the roof of Bus shelter. The solar power plant shall consist of required no of SPV Panels, string type grid tied invertor, AC Distribution Board, AC & DC Cables, Earthing system, Lightning Arrestor system and with all other electrical items as necessary required for completion. The job shall be including of all necessary civil works, providing of module mounting structure and others as required.

52

-

-

... More
Dismantling steel work in built up sections in angles, tees, flats ,structural member and channels including all gusset plates, bolts, nuts, cutting rivets, welding, foundation ,Roofing sheet, Seating/benches/ Signage Boards/Display penel etc. including dismembering and stacking within 50 metres lead.

360

-

-

... More
For locking paverblocks:Providing and cast in situ C.C. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete

667.7

-

-

... More
Transplantation of Standing Trees of Girth from 250 mm to 1250mm-: Transplantation of Trees including excavation, bar lapping, lifting, loading, transportation, and transplanting. Digging pits, manure or sludge, sand, fertilizer, growth hormone/rootex/bio fertilizer, guying, flooding with water, dressing including removal of rubbish and surplus earth, with 1 year maintenance including weeding, watering, spraying, guying and fertilizer application. Maintenance period will be starting after transplantation of Tree. (i)Transplanting of trees within 10 km radius from its location to the proposed location (ii) Maintenance of Trees i.e watering manuring soil heaping spray of insecticide etc till the sprouting and establishment of trees up to 12 months

30

-

-

... More
Transplantation of Standing Trees of Girth from 1250 mm to 5000 mm -: Transplantation of Trees including excavation, bar lapping, lifting, loading, transportation, and transplanting. Digging pits, manure or sludge, sand, fertilizer, growth hormone/rootex/bio fertilizer, guying, flooding with water, dressing including removal of rubbish and surplus earth, with 1 year maintenance including weeding, watering, spraying, guying and fertilizer application. Maintenance period will be starting after transplantation of Tree. (i)Transplanting of trees within 10 km radius from its location to the proposed location (ii) Maintenance of Trees i.e watering manuring soil heaping spray of insecticide etc till the sprouting and establishment of trees up to 12 months

20

-

-

... More
Storm Water Drain Works

-

-

-

... More
Dismantling Existing SWD-Demolition including stacking of serviceable materials and disposal of unserviceable materials with all lead and lift (i) R.C.C work

32552.4

-

-

... More
Filling in foundation and plinth with murrum or selected soil in layers of 20cm thickness including watering, ramming and consolidating etc. complete. (more than 10 ton)

89722.2

-

-

... More
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose or soft soil

133194.1

-

-

... More
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil

133789.9

-

-

... More
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (C) Hard Murrum

66597.1

-

-

... More
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil

10495.6

-

-

... More
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (C) Hard Murrum

52477.9

-

-

... More
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (D) Soft rock not requiring Blasting

31486.7

-

-

... More
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (E) Hard Rock

10495.6

-

-

... More
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing of the excavated stuff upto 50 Meter lead. (C) Hard Murrum

962.8

-

-

... More
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (D) Soft rock not requiring Blasting

2406.9

-

-

... More
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (E) Hard Rock

1444.1

-

-

... More
Excavation in bituminous road as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts as specified.

595.8

-

-

... More
Wooden Shoring- Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). Depth exceeding 1.5 m but not exceeding 3 m

340593.3

-

-

... More
Wooden Shoring -Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). Depth exceeding 3 m but not exceeding 4.5 m

2967.5

-

-

... More
Gravel Filling Below Drain Raft-Collecting, carting of unscreened gravel at site of work including spreading in required layers, watering and consolidation the same with vibratory roller etc. complete and as directed by Engineer in charge.

35334.8

-

-

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering.

157948.2

-

-

... More
PCC in M10:Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp. to prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl. consolidation curing etc. complete.Without Forms Work

17509.6

-

-

... More
PCC in M15: Providing and casting in situ Cement concrete in grade M-15 (approx. corresp. to prop. 1:2:4) (proportions as per mix design or as per Table 9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing complete (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. complete for Foundations, footings,Base of columns and Mass concrete

79.4

-

-

... More
Raft-Providing and cast in situ Cement Concrete in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete in Flat bottom slab/raft/floor slab/slab

30421.7

-

-

... More
Wall: Providing and cast in situ Cement Concrete in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete for Vertical RCC wall

57643.2

-

-

... More
Slab:Providing and cast in situ Cement concrete in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete Flat bottom slab/raft/floor slab/slab with shuttering

30383.7

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO))

9905223.4

-

-

... More
Constructing RCC Inlet chamber of internal dimension (300L X 300B x 400D mm) along the road edges for inlet to stormwater drain in M25 cement concrete and with Fe-500 D steel reinforcement including SITC heavy duty (minimum 20 Tonne) SFRC frame & grating of grade M- 35 as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO, including laying & fixing of 200mm dia Upvc inlet pipe in proper gradient so as to discharge rain water in adjacent storm water drain properly. Chamber have to constructed over well compacted subgrade and over base of PCC in cement concrete 1:3:6. all shall have to be to the satisfaction of Engineer-in-charge and as per typical section tender drawing

7527

-

-

... More
MS Footsteps- Providing and fixing plastic encapsulated M.S. foot rest 30x20x15 cm

28033

-

-

... More
Drain Pipes for inlet to Storm Drains (750mm length)-- Providing and supplying in standard length ISI mark rigid unplasticised PVC pipes suitable for potable water with ring fit joint including cost of rings, as per IS specification no. 4985/1988 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores and including cost of jointing meterial etc. complete. UPVC Test Pressure 6 Kg/cm2 - Size - 200mm

5645.3

-

-

... More
Lowering, laying, fixing and jointing PVC/uPVC/cPVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of labour, material, cement solvent, giving satisfactory hydraulic testing as per ISI code. (750mm length) UPVC Test Pressure 6 Kg/cm2 - Size - 200mm

5645.3

-

-

... More
SITC of SFRC precast Frame & Cover for SWD inspection chamber as per design & manufacture standards in M- 35 grade CC with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work. Light duty (5 – Tonne) Frame & cover Internal dimension 600 x 450 mm. as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO,

4651

-

-

... More
SITC of SFRC precast Frame & Cover for SWD inspection chamber as per design & manufacture standards in M- 35 grade CC.with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work Heavy duty (20 – Tonne) duty Frame & cover/grating Internal dimension 600 x 450 mm as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO,

310

-

-

... More
Labour for fixing precast R.C.C. Cover and frame

4961

-

-

... More
Disposing of available Excavated Stuff up to 5.0km lead including spreading/filling and levelling to gradient camber as directed with all lead and lift and on road side embankment with breaking clods dressing etc. complete as directed by Engineer-in-Charge..

287247.7

-

-

... More
Clearing and grubbing road land including uprooting rank vegetation grass bushes, shrubs, sapling and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials (B) By manual means in area of thorny jungle

0.1

-

-

... More
Road & Median Restoration

480

-

-

... More
Underground Utility restoration at 10% of total cost of Nalla Diversion work

1

-

-

... More
Storm Water Drain Outfall Structures- Excavation for foundation in sand, gravel, clay soft soils and murrum etc. including shoring, strutting, dewatering as necessary and disposing of the excavated stuff as directed. (A) Depth upto 3.0 M. and lead upto 100m for 10 Cum

4137.9

-

-

... More
Gravel Bedding for head wall Foundation- Collecting, carting of unscreened gravel at site of work including spreading in required layers, watering and consolidation the same with vibratory roller etc. complete and as directed by Engineer in charge.

227.9

-

-

... More
PCC in M15: Providing and casting in situ Cement concrete in grade M-15 (approx. corresp. to prop. 1:2:4) (proportions as per mix design or as per Table 9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing complete (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. complete for Foundations, footings,Base of columns and Mass concrete

76

-

-

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering.

3489.5

-

-

... More
Raft-Providing and cast in situ Cement Concrete in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete in Flat bottom slab/raft/floor slab/slab

173.3

-

-

... More
RCC Head Wall-Wall: Providing and cast in situ Cement Concrete i in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete for Vertical RCC wall

214.1

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO))

29057.2

-

-

... More
weep hole in Head Wall- Providing & laying weep hole in Aburtments, and returns by using A.C. pipe of 100mm including laying in proper grede and jointing the completed as per detailed specification. (in gride of 1.5hx1.0vm C/C )

542

-

-

... More
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.

6291.6

-

-

... More
75 mm thick back filling for pitching including supplying of required materials and consolidation etc. complete with -Stone aggregate 20 mm nominal size

6291.6

-

-

... More
Tap-Off Arrangement Works

-

-

-

... More
Sewer_Tap Off Arrangement Works Dismantling and Demolishing -Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift

9166.8

-

-

... More
Providing and laying rough chiseled dressed stone flooring over 20mm average thick base of cement mortar 1:5 (1-Cement : 5- coarse sand) or L.M. 1:1.5 (1-Lime putty : 1.5 - coarse sand) including pointing with cement mortar 1:2 (1-cement : 2-stone dust) etc. complete. (A) 25mm thick (upto 10 ton)

9166.8

-

-

... More
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 0 to 1.5m

13502.5

-

-

... More
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 1.5 to 3m

5574.9

-

-

... More
Excavation for RCC Pipe: Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. Excavation 0 to 1.5m

11599.7

-

-

... More
Excavation for RCC Pipe: Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. Excavation 1.5 to 3m

2390.6

-

-

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. - Around RCC chamber

12927.9

-

-

... More
Refilling of sand In Pipe trench-Providing bedding incl. ramming, watering, levelling, consolidating etc. Complete as per standard and instruction of engineer incharge

8303.1

-

-

... More
PCC in M10:Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp. to prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl. consolidation curing etc. complete.Without Forms Work

388.2

-

-

... More
Raft-Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete in Flat bottom slab/raft/floor slab/slab

484.5

-

-

... More
Wall: Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete for Vertical RCC wall

2225.3

-

-

... More
Slab:Providing and cast in situ Cement concrete in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete Flat bottom slab/raft/floor slab/slab with shuttering

175.6

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO))

173137

-

-

... More
Providing and supplying 150mm Dia DWC Pipe (-Providing and supplying of class SN8 structured wall polyethelene piping system (Pipe with on-line/ off-line coupler and elasomeric sealing ring) with non smooth external annular corrugated and smooth internal surfaces (Double wall for non pressure underground sewerage & drainage application as per IS 16098 (P2) including all local and central taxes transportation , freight charges octroi,inspection charges loading unloading conveyance to the departmental stores etc., complete (ID dia) 150mm DWC Pipe -Inspection chamber to Manhole connection across the road

14480

-

-

... More
L,L& J of Corruguated-Loweing,laying and jointing class SN8 structured wall (External annular corrugated & Smooth internal surface Polyethelene piping and fittings with the help of coupler ( online/ off line) attached with one end of pipe sliding over the elastomeric seling rubber ring placed on the specified valley of the corrogation at the spigot end, lowering the same in to the trench laying on the loer bedding ( constructed at bottom of trenches at prescribed gradient ,depth and alignment testing the water tightness of the joints ,ensuring the continuity tests of specified pipe segments etc., complete as per drawing ,specifications & detailed engineering ,including carriage of pipes & fittings from site stacks to the place of laying etc., as per the direction of Engineer-in -Charge. DWC HDPE pipes (Non pressure underground sewerage & Drainage applications)- 150mm DWC Pipe -Connection of Inspection Chamber to Manhole 0 to 1.5m

14480

-

-

... More
Making connection of drain or sewer line of size 100 to 230mm external dia with existing / new manhole including breaking into and making good the walls, floors with cement concrete M15 with 20mm and downsize granite metal, cement plastered on both sides of mix 1:3, finished with a floating coat of neat cement, and making necessary channels for the drain, including cost of materials, labour charges, curing complete as per specifications.

2088

-

-

... More
SITC of SFRC precast Frame & Cover for Sewer Tap Off property side chamber as per design & manufacture standards in M- 35 grade CC with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work. Light duty (5 – Tonne) Frame & cover Internal dimension 600 x 600 mm. as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO,

2088

-

-

... More
Labour for fixing precast SFRC Cover and frame

2088

-

-

... More
Excavation for RCC Pipe: Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. Excavation 0 to 1.5m

42120

-

-

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering.

28801

-

-

... More
Providing and supplying 150mm Dia DWC Pipe-Providing and supplying of class SN8 structured wall polyethelene piping system (Pipe with on-line/ off-line coupler and elasomeric sealing ring) with non smooth external annular corrugated and smooth internal surfaces (Double wall for non pressure underground sewerage & drainage application as per IS 16098 (P2) including all local and central taxes transportation , freight charges octroi,inspection charges loading unloading conveyance to the departmental stores etc., complete (ID dia) 150mm DWC Pipe -(DWC pipe is for in between Inspection chambers along the road.)

58500

-

-

... More
L,L& J of Corruguated-Loweing,laying and jointing class SN8 structured wall (External annular corrugated & Smooth internal surface Polyethelene piping and fittings with the help of coupler ( online/ off line) attached with one end of pipe sliding over the elastomeric seling rubber ring placed on the specified valley of the corrogation at the spigot end, lowering the same in to the trench laying on the loer bedding ( constructed at bottom of trenches at prescribed gradient ,depth and alignment testing the water tightness of the joints ,ensuring the continuity tests of specified pipe segments etc., complete as per drawing ,specifications & detailed engineering ,including carriage of pipes & fittings from site stacks to the place of laying etc., as per the direction of Engineer-in -Charge. DWC HDPE pipes (Non pressure underground sewerage & Drainage applications)- 150mm DWC Pipe -Connection of Inspection Chamber to Manhole 0 to 1.5m

58500

-

-

... More
Bedding to DWC Pipe-Providing bedding incl. ramming, watering, levelling, consolidating etc. Complete as per standard and instruction of engineer incharge, with Murrum brought from outside inclduing all lead

7020

-

-

... More
Gas Line_Tap Off Arrangement Works Dismantling and Demolishing -Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.

2948

-

-

... More
Providing and laying rough chiseled dressed stone flooring over 20mm average thick base of cement mortar 1:5 (1-Cement : 5- coarse sand) or L.M. 1:1.5 (1-Lime putty : 1.5 - coarse sand) including pointing with cement mortar 1:2 (1-cement : 2-stone dust) etc. complete. (A) 25mm thick (upto 10 ton)

2948

-

-

... More
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 0 to 1.5m

10970.7

-

-

... More
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 1.5 to 3m

4011.4

-

-

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. - Around RCC chamber

9447.2

-

-

... More
Refilling Sand in Chamber- Providing and filling sand below R.C.C. Raft in Layers including ramming and watering complete.

2437.6

-

-

... More
PCC in M10:Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp. to prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl. consolidation curing etc. complete.Without Forms Work

344.9

-

-

... More
Raft-Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete in Flat bottom slab/raft/floor slab/slab

469.5

-

-

... More
Wall: Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete for Vertical RCC wall

1895.9

-

-

... More
Slab:Providing and cast in situ Cement concrete in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete Flat bottom slab/raft/floor slab/slab with shuttering

201.4

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO)

234015.9

-

-

... More
SITC of SFRC precast Frame & Cover for GAS Tap Off road side chamber as per design & manufacture standards in M- 35 grade CC with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work. Heavy duty ( 20– Tonne) Frame & cover Internal dimension 600 x 600 mm. as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO,

737

-

-

... More
SITC of SFRC precast Frame & Cover for GAS Tap Off property side chamber as per design & manufacture standards in M- 35 grade CC with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work. Light duty ( 20– Tonne) Frame & cover Internal dimension 600 x 600 mm. as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO,

737

-

-

... More
Labour for fixing precast SFRC Cover and frame

1474

-

-

... More
Water Line_Tap Off Arrangement Works Dismantling and Demolishing -Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift

4682

-

-

... More
Providing and laying rough chiseled dressed stone flooring over 20mm average thick base of cement mortar 1:5 (1-Cement : 5- coarse sand) or L.M. 1:1.5 (1-Lime putty : 1.5 - coarse sand) including pointing with cement mortar 1:2 (1-cement : 2-stone dust) etc. complete. (A) 25mm thick (upto 10 ton)

4682

-

-

... More
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 0 to 1.5m

14567.9

-

-

... More
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 1.5 to 3m

2905.1

-

-

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. - Around RCC chamber

9791.5

-

-

... More
Refilling Sand in Chamber- Providing and filling sand below R.C.C. Raft in Layers including ramming and watering complete.

3643.4

-

-

... More
PCC in M10:Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp. to prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl. consolidation curing etc. complete.Without Forms Work

556.3

-

-

... More
Raft-Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete in Flat bottom slab/raft/floor slab/slab

768.2

-

-

... More
Wall: Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete for Vertical RCC wall

2056.3

-

-

... More
Slab:Providing and cast in situ Cement concrete in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete Flat bottom slab/raft/floor slab/slab with shuttering

393.8

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO)

291495.8

-

-

... More
Labour charges - Hole Driller- Drilling of holes in 250 mm thick in a RCC wall, Main SWD Inlets ( 150-300 mm dia)

3120

-

-

... More
Providing and supplying of class SN8 structured wall polyethelene piping system (Pipe with on-line/ off-line coupler and elasomeric sealing ring) with non smooth external annular corrugated and smooth internal surfaces (Double wall for non pressure underground sewerage & drainage application as per IS 16098 (P2) including all local and central taxes transportation , freight charges octroi, inspection charges loading unloading conveyance to the departmental stores etc., complete (Pipe diameter 100 mm ID)

2086.5

-

-

... More
Providing and supplying ISI mark G. I. pipes with Couplings of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS -1239) (Not for well/tube well column pipe) (Heavy Duty) 80 mm dia GI Heavy duty

2730

-

-

... More
Providing and supplying ISI mark G. I. pipes with Couplings of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS -1239) (Not for well/tube well column pipe) (Heavy Duty) 25 mm dia GI Heavy Duty

1560

-

-

... More
Providing and supplying ISI mark G. I. pipes with Couplings of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS -1239) (Not for well/tube well column pipe) (Heavy Duty) 20 mm dia GI Heavy Duty

780

-

-

... More
Loweing,laying and jointing class SN8 structured wall (External annular corrugated & Smooth internal surface Polyethelene piping and fittings with the help of coupler ( online/ off line) attached with one end of pipe sliding over the elastomeric seling rubber ring placed on the specified valley of the corrogation at the spigot end, lowering the same in to the trench laying on the loer bedding ( constructed at bottom of trenches at prescribed gradient ,depth and alignment testing the water tightness of the joints ,ensuring the continuity tests of specified pipe segments etc., complete as per drawing ,specifications & detailed engineering ,including carriage of pipes & fittings from site stacks to the place of laying etc., as per the direction of Engineer-in -Charge. placing & Fixing 100mm DWC Pipe -conduit from road side chamber to Property side chamber with RCC drain wall drilling

780

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer in-charge including hydraulic testing etc. comp. 80 mm dia GI Heavy duty

2730

-

-

... More
Lowering, laying and jointing G. I. pipes with G. I. specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing, etc. comple 20mm & 25mm dia GI Heavy duty

2340

-

-

... More
Providing and making flanged joints to flanged DI /GI/ C.I. pipes of all classes / specials etc. including cost of all jointing materials rubber packing, nut bolts, inclduing lowering laying jointing labour hydraulic testing etc. complete. 80 mm dia GI Heavy duty

2340

-

-

... More
Providing & fixing gun metal check or non return full-way wheel valve 25 mm dia GI Heavy duty

1560

-

-

... More
Providing & fixing gun metal check or non return full-way wheel valve 20 mm dia GI Heavy duty

1560

-

-

... More
Providng and fixing GI/ DI pipeline specials bend, tee, elbow,union, double nepple,flange end cap heavy duty for jointing etc complete as directed by engineer in charge.

1

-

-

... More
SITC of SFRC precast Frame & Cover for Water Tap Off road side chamber as per design & manufacture standards in M- 35 grade CC with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work. Heavy duty ( 20– Tonne) Frame & cover Internal dimension 600 x 600 mm. as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO,

780

-

-

... More
SITC of SFRC precast Frame & Cover for Water Tap Off property side chamber as per design & manufacture standards in M- 35 grade CC with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work. Light duty ( 20– Tonne) Frame & cover Internal dimension 600 x 600 mm. as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO,

780

-

-

... More
Labour for fixing precast SFRC. Cover and frame

1560

-

-

... More
OFC Line_Tap Off Arrangement Works Dismantling and Demolishing -Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.

3528

-

-

... More
Providing and laying rough chiseled dressed stone flooring over 20mm average thick base of cement mortar 1:5 (1-Cement : 5- coarse sand) or L.M. 1:1.5 (1-Lime putty : 1.5 - coarse sand) including pointing with cement mortar 1:2 (1-cement : 2-stone dust) etc. complete. (A) 25mm thick (upto 10 ton)

3528

-

-

... More
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 0 to 1.5m

10100.6

-

-

... More
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 1.5 to 3m

2024.7

-

-

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. - Around RCC chamber

8152.9

-

-

... More
Refilling Sand in Chamber- Providing and filling sand below R.C.C. Raft in Layers including ramming and watering complete.

1620.7

-

-

... More
PCC in M10:Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp. to prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl. consolidation curing etc. complete.Without Forms Work

338.9

-

-

... More
Raft-Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete in Flat bottom slab/raft/floor slab/slab

391.6

-

-

... More
Wall: Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete for Vertical RCC wall

1319.7

-

-

... More
Slab:Providing and cast in situ Cement concrete in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete Flat bottom slab/raft/floor slab/slab with shuttering

139.1

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO)

170259.1

-

-

... More
Labour charges - Hole Driller- Drilling of holes in 250 mm thick in a RCC wall, Main SWD Inlets ( 150-300 mm dia)

3528

-

-

... More
Providing and supplying of class SN8 structured wall polyethelene piping system (Pipe with on-line/ off-line coupler and elasomeric sealing ring) with non smooth external annular corrugated and smooth internal surfaces (Double wall for non pressure underground sewerage & drainage application as per IS 16098 (P2) including all local and central taxes transportation , freight charges octroi, inspection charges loading unloading conveyance to the departmental stores etc., complete (ID dia)

2359.4

-

-

... More
Loweing,laying and jointing class SN8 structured wall (External annular corrugated & Smooth internal surface Polyethelene piping and fittings with the help of coupler ( online/ off line) attached with one end of pipe sliding over the elastomeric seling rubber ring placed on the specified valley of the corrogation at the spigot end, lowering the same in to the trench laying on the loer bedding ( constructed at bottom of trenches at prescribed gradient ,depth and alignment testing the water tightness of the joints ,ensuring the continuity tests of specified pipe segments etc., complete as per drawing ,specifications & detailed engineering ,including carriage of pipes & fittings from site stacks to the place of laying etc., as per the direction of Engineer-in -Charge. placing & Fixing 100mm DWC Pipe -conduit from road side chamber to Property side chamber with RCC drain wall drilling

2359.4

-

-

... More
SITC of SFRC precast Frame & Cover for OFC Tap Off road side chamber as per design & manufacture standards in M- 35 grade CC with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work. Heavy duty ( 20– Tonne) Frame & cover Internal dimension 600 x 600 mm. as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO,

882

-

-

... More
SITC of SFRC precast Frame & Cover for OFC Tap Off property side chamber as per design & manufacture standards in M- 35 grade CC with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work. Light duty ( 20– Tonne) Frame & cover Internal dimension 600 x 600 mm. as per approved make KK manhole & grating co, Royal cement, Nu -Tech concrete, Agrawal cement fabricating or as per approved by CTO,

882

-

-

... More
Labour for fixing precast SFRC Cover and frame

1764

-

-

... More
Laying 150mm Dia. Pipe Conduit for Future OFC Provision 150mm Dia. Pipe Conduit for future OFC provision-Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 0 to 1.5m

58108

-

-

... More
150mm Dia. Pipe Conduit for future OFC provision-Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering.

56054.3

-

-

... More
150mm Dia. Pipe Conduit for future OFC provision-Supply, Providing & laying of approved make Double walled corrugated pipes (DWC) having diameter OD is 172.5 mm and ID is 150 MM of polyethylene (conforming to IS 14930 II) with necessary connecting accessories of same material at required depth for laying of ICT cables below ground/ road surface for enclosing cable and back filling the same to make ground as per original.

116216

-

-

... More
Cross Drainage Work

-

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Bhutarfaliya road to Bavishafaliya primary school_Rd-46- Dismantling of existing 2 no pipe having diameter 0.5m and approximate length 12 m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

2

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Pataliya faliya (Sundervan Garden) to Varliwada_Rd-55- Dismantling of existing 1no pipe having diameter 0.5m and approximate length 12m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Kamblifaliya Main Road to Shreebliss Residency_Rd-73- Dismantling of existing 3no pipe having diameter 1m and approximate length 7.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Shree Residency to Sona Enclave._Rd-74- Dismantling of existing 1no pipe having diameter 1m and approximate length 7.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Bhurkudfaliya main road to Bhurkud faliya primary school._Rd-75- Dismantling of existing 3no pipe having diameter 1.2m and approximate length 11.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Dandulfaliya Internal Road to Baldevi Smashan Road_Rd-119- Dismantling of existing 1no pipe having diameter 0.75m and approximate length 11.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Internal road (Baldevei primary school road to Baldevi Smashan road)_Rd-120- Dismantling of existing 2no pipe having diameter 0.75m and approximate length 7.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Road emerging from Sayli main road to Athola boarder_Rd-121- Dismantling of existing 1no pipe having diameter 0.75m and approximate length 7.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

6

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Road emerging from Sayli main road to Athola boarder_Rd-121- Dismantling of existing 3no pipe having diameter 0.5m and approximate length 7.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Road emerging from Sayli main road to Athola boarder_Rd-121- Dismantling of existing 5no pipe having diameter 1m and approximate length 7.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Baldevi Navlafaliya internal road_Rd-122- Dismantling of existing 2no pipe having diameter 1m and approximate length 7.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Baldevi Navlafaliya internal road_Rd-122- Dismantling of existing 1no pipe having diameter 1m and approximate length 7.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert @ Sayli - Vejal pada road_Rd-125- Dismantling of existing 1no pipe having diameter 1m and approximate length 11.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert using existing Pipe@ Shree Residency Bhurkudfaliya to Kamblifaliya road._Rd-70- Dismantling of existing 1no pipe having diameter 0.5m and approximate length 11.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert using existing Pipe@ Dockmardi Industrial Estate Road._Rd-108- Dismantling of existing 3no pipe having diameter 0.5m and approximate length 7.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert using existing Pipe@ Gandhigram Talavfaliya towards Mahdev Mandir_Rd-112- Dismantling of existing 1no pipe having diameter 0.5m and approximate length 11.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert using existing Pipe@ Dandulfaliya junction to Sayli Main Road Baldevi Primary School Road_Rd-114- Dismantling of existing 1no pipe having diameter 0.75m and approximate length 11.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

2

-

-

... More
Dismantling & Reconstruction of Pipe culvert using existing Pipe @ nternal Road (Gandhigram Main Road to Athola Border.)_Rd-115- Dismantling of existing 3no pipe having diameter 1m and approximate length 11.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert using existing Pipe @ nternal Road (Gandhigram Main Road to Athola Border.)_Rd-115- Dismantling of existing 5no pipe having diameter 1m and approximate length 11.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Dismantling & Reconstruction of Pipe culvert using existing Pipe @ Baldevi - Delkarfaliya internal road. _Rd-128- Dismantling of existing 1no pipe having diameter 1m and approximate length 11.5m of pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Pipe Culvert, designed for 'AA' class and 'A' Class loading as per IRC SP-13 and other relevant Indian standard specifications including the effect of impact, etc. complete on firm base, constructing head walls & return wall in Min M25 Grade reinforced CC at both ends, pipe shall be RCC NP4 class, stone pitching on both side, work also includes required safety measures, construction of Temporary drain for diversion of drain water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, painting & all allied works, complete in all respect. Cost of design of Pipe culvert & including approval of detailed designs, Good For Construction Drawings as per relevant Indian standards and Tender specifications.

1

-

-

... More
Providing and Construction of cast-in-situ RCC Box Culvert for Widening of existing culvert @ Officers Colony Road of Size of widening -(5.2Wx2DX3L)m on both side_Rd-62- Design and construction of Precast RCC Box Culvert of minimum size (5.2Wwx2Dx3L)m on Bth side of culvert in M-30 grade CC designed for 'AA' class and 'A' Class loading as per IRC specifications including the effect of impact, EQ etc. complete on firm base plain cement concrete of M-15 grade, propoer splicing of new work reinforcement with existing structure so as to achive propoer connection with existing culvert, work also includes required safety measures, construction of drain for diversion of flowing water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, provision for laying of utility lines, Natural Stone Works, & all allied works, complete in all respect. Cost of design of inculding approval of detailed designs, Good For Construction Drawings as per relevent indian standards and specifications.

1

-

-

... More
Providing and Laying of Precast RCC Box Culvert @ Baldevi primary school road_Rd-114- Dismantling of existing 6no of 1m dia. pipe culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Precast RCC Box Culvert of minimum size (4wx2Dx12.5L)m in M-40 grade CC designed for 'AA' class and 'A' Class loading as per IRC specifications including the effect of impact, EQ etc. complete on firm base plain cement concrete of M-15 grade, work also includes required safety measures, construction of drain for diversion of flowing water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, & all allied works, complete in all respect. Cost of design of RCC Precast Box and its proof checking the same from IIT/ any Govt. institution approved by the Employer & inculding approval of detailed designs, Good For Construction Drawings as per relevent indian standards and specifications.

1

-

-

... More
Providing and Laying of Precast RCC Box Culvert @ Tokarkhada Church to Dan Hotel up to patalia falia_Rd-53- Dismantling of existing (5Wx1.8Dx12L)m RCC Slab culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Precast RCC Box Culvert of minimum size (3.5wx3.5Dx12L)m in M-40 grade CC designed for 'AA' class and 'A' Class loading as per IRC specifications including the effect of impact, EQ etc. complete on firm base plain cement concrete of M-15 grade, work also includes required safety measures, construction of drain for diversion of flowing water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, & all allied works, complete in all respect. Cost of design of RCC Precast Box and its proof checking the same from IIT/ any Govt. institution approved by the Employer & inculding approval of detailed designs, Good For Construction Drawings as per relevent indian standards and specifications.

1

-

-

... More
Providing and Construction of cast-in-situ RCC Box Culvert @ RCC Box Culvert At Piparia Industrial Estate Main Road of Size-(4.5Wx3.5Dx12L)_Rd-93- Dismantling of existing (4Wx3.2Dx12L)m Masonary wall & RCC Slab culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Precast RCC Box Culvert of minimum size (4.5wx3.5Dx12L)m in M-30 grade CC designed for 'AA' class and 'A' Class loading as per IRC specifications including the effect of impact, EQ etc. complete on firm base plain cement concrete of M-15 grade, work also includes required safety measures, construction of drain for diversion of flowing water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, provision for laying of utility lines & all allied works, complete in all respect. Cost of design of RCC Box culvert and its proof checking the same from IIT/ any Govt. institution approved by the Employer & inculding approval of detailed designs, Good For Construction Drawings as per relevent indian standards and specifications.

1

-

-

... More
Providing and Construction of cast-in-situ RCC Box Culvert @ RCC Box Culvert At Piparia Industrial Estate Main Road of Size-(7wx7x12L)_Rd-93- Dismantling of existing (6.5Wx6.7Dx12L)m Masonary wall & RCC Slab culvert, Decommissioning and removal of defunct utility lines, RCC Pipes, etc. including design and construction of Precast RCC Box Culvert of minimum size (7wx7x12L)m in M-30 grade CC designed for 'AA' class and 'A' Class loading as per IRC specifications including the effect of impact, EQ etc. complete on firm base plain cement concrete of M-15 grade, work also includes required safety measures, construction of drain for diversion of flowing water, enabling/temporary works, earth cutting, filling works, under water and above water, RCC works, Natural Stone Works, provision for laying of utility lines, & all allied works, complete in all respect. Cost of design of RCC of RCC Box culvert and its proof checking the same from IIT/ any Govt. institution approved by the Employer & inculding approval of detailed designs, Good For Construction Drawings as per relevent indian standards and specifications.

1

-

-

... More
Miscellaneous Civil Works

-

-

-

... More
RCC Retaining wall along road- Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 0 to 1.5m

26918.2

-

-

... More
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.. Excavation 1.5 to 3m

5763.4

-

-

... More
Gravel Filling Below Raft-Providing, Supplying, Collecting, carting of unscreened gravel at site of work including spreading in required layers, watering and consolidation the same with vibratory roller etc. complete and as directed by Engineer in charge.

2006.6

-

-

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. - Around RCC chamber

26417.8

-

-

... More
PCC in M10:Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp. to prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl. consolidation curing etc. complete.Without Forms Work

1003.3

-

-

... More
Raft-Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete in Flat bottom slab/raft/floor slab/slab

3148.2

-

-

... More
Wall: Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete for Vertical RCC wall

4716.4

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO)

783587.8

-

-

... More
Expansion Gap -Providing and laying and fixing 25 mm thick expansion joint by hydro cell semi rigid UV resistance with high performance laminated closed cell polythene foam joint filler in sheet foam as directed, etc. complete.

151

-

-

... More
weep hole in Head Wall- Providing & laying weep hole in Aburtments, and returns by using A.C. pipe of 100mm including laying in proper grede and jointing the completed as per detailed specification. (in gride of 1.5hx1.0vm C/C )

4325

-

-

... More
Safety MS Grill, Railing, Gate -Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at required spacings and frame alround, square or round bars with round headed bolts and nuts or by screws. Complete (B) ORNAMENTAL GRILL (upto 10 ton) ( for Railing on island for collectorate road)

5463

-

-

... More
CC pavement for Panchayat Market Road (to match Proposed diverted SWD level )- -Providing and cast in situ Cement Concrete i. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation and curing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete in Flat bottom slab/raft/floor slab/slab

120.2

-

-

... More
Wearing Coat for Panchayat Market Road-Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO)

3607.3

-

-

... More
Existing utility shifting (Water Supply Pipeline) Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work

584.1

-

-

... More
Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar.

817.8

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-In all sorts of soil and soft murrum:Upto 1.5 m

8094.6

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-In hard murrum, boulders incl. macadam road and In soft rock and/or masonry in CM or L M or Lime Concrete.Upto 1.5 m

4047.3

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-In hard rock and / or in C. C. 1:2:4 or RCC with breaking, chiseling, or by chiseling / breaking only (Blasting Prohibited)Upto 1.5 m

4047.3

-

-

... More
Dewatering in all sorts of soil and soft murrum, hard Murrum and boulders, Soft Rock, Hard Rock, upto 1.5 mt. depth from G.L.- Depth not exceeding 1.5m

140.2

-

-

... More
Providing bedding incl. ramming, watering, levelling, consolidating etc. Complete as per standard and instruction of engineer-in-charge. (As above with selected excavated earth available near site)

1823

-

-

... More
Refilling the pipeline trenches incl. ramming, watering, consolidating desposal of surplus stuff as directed within a radius of 3 km.Refilling as directed (depth between 0 to 6m)

11094.5

-

-

... More
Refilling the pipeline trenches incl. ramming, watering, consolidating desposal of surplus stuff as directed within a radius of 3 km-with selected soil brought from outside including all lead

2773.6

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). Rate for DI pipe based on Wholesale Price index of Pig Iron as 114.20 for the month of Febuaury-2019-150MM DIA Approved make M/s. Tata Metaliks Limited, M/s. Electrosteel Castings Ltd., M/s. Electrotherm (I) Ltd., M/s Jindal ltd or as approved by Chief Technical Officer (CTO).

8814.4

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). Rate for DI pipe based on Wholesale Price index of Pig Iron as 114.20 for the month of Febuaury-2019-200mm DIA Approved make M/s. Tata Metaliks Limited, M/s. Electrosteel Castings Ltd., M/s. Electrotherm (I) Ltd., M/s Jindal ltd or as per the or as approved by Chief Technical Officer (CTO).

4110.4

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). Rate for DI pipe based on Wholesale Price index of Pig Iron as 114.20 for the month of Febuaury-2019-250mm dia pipe Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

2652

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete.-150mm dia

8814.4

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete.-200mm dia

4110.4

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete.-250mm dia

2652

-

-

... More
Manufacture, supply and delivery of 80 mm to 400 mm dia cast iron flange ended specials complete as per IS: 5531-1977 (Part- I to III) or its latest revision if any, suitable for use with A.C. Pressure pipes manufactured as per IS: 1592-1989 or its latest revision for various dia meter and classes. The delivery of specials is to be made to GWSSB store or sites any where in Gujarat States including all taxes, loading, carting, unloading, stacking, insurance, octroi, inspection charges etc. complete

55

-

-

... More
Providing and supplying ISI mark CI D/F Sluice Valves (Manual Operation) as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete PN 1 Diameter 150. Approved make Kirloskar Brothers Ltd, IVC, AVK ltd or as approved by Chief Technical Officer (CTO).

18

-

-

... More
Providing and supplying ISI mark CI D/F Sluice Valves (Manual Operation) as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete PN 1 Diameter 200.Approved make Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

8

-

-

... More
Providing and supplying ISI mark CI D/F Sluice Valves (Manual Operation) as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete PN 1 Diameter 250.Approved make Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

5

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilint Sluice Valves -150 mm Dia

18

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilint Sluice Valves -200 mm Dia

8

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilint Sluice Valves -250 mm Dia

5

-

-

... More
Valve Chamber (Sluice): Construction of RCC Chamber of size 1mx1mx1.5 m D, for sluice valve including suitable size SFRC HD frame & cover, surface box, Lifting eye, with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work, PCC in M-15 grade CC of 100mm thick, all RCC work shall be in M25 grade CC, Centring and shuttering including strutting, propping etc. and removal of form work, steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, and binding all complete work, back filling available excavated earth (excluding rock), and safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 with all other requirement to make the structure operational, complete to the satisfaction of EIC.

31

-

-

... More
Air Valves-Providing and supplying C. I. Air valves of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. Diameter 80 mm- Double Acting. Approved make M/s. Kirloskar Brothers Ltd., M/s. VAG Valves India Pvt. Ltd. M/s IVI ltd, or as approved by Chief Technical Officer (CTO).

39

-

-

... More
Lowering, laying and jointing in position CI Air Valve including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-Air Valves -80 mm Dia

39

-

-

... More
Valve Chamber (Air): Construction of RCC Chamber of size 1mx1mx1.3 m D, for sluice valve including suitable size SFRC HD frame & cover, surface box, Lifting eye, with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work, PCC in M-15 grade CC of 100mm thick, all RCC work shall be in M25 grade CC, Centring and shuttering including strutting, propping etc. and removal of form work, steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, and binding all complete work, back filling available excavated earth (excluding rock), and safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 with all other requirement to make the structure operational, complete to the satisfaction of EIC.

39

-

-

... More
Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp. to prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl. consolidation curing etc. complete.Without Forms Work

72.4

-

-

... More
Thrust Block -Providing and cast in situ C.C. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation, curing and hydraulic testing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. comp. up to 6 meter height /depth Av. G.L.for all water retaining structures -Providing M-30 grade concrete instead of M-25 grade BMC / RMC. (Note:- Cement content considered in M-30 is @ 340kg / cum)

269.4

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO)

14.6

-

-

... More
Street Lighting Works

-

-

-

... More
Decorative Street Light Pole with Double Arm Bracket- Supply, installation, testing and commissioning of following type of Decorative Chatsworth Street Light Pole with Decorative Cascade Bracket suitable for Pendant type street lighting luminaires (Both side). The architecturally designed pole shall be structurally sound. The pole shaft shall have swaged/ tubular cross section and shall be continuously tapered with single longitudinal welding. All pole sections are swaged and joined together using high end MIG welding process and tested for its quality through NDT method, such as DP Test. All decorative pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. Batch test reports for chemical and mechanical properties of material should be submitted along with the bid. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The decorative poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The decorative pole shall be of ‘composite’ construction designed to withstand specified ‘dead load’ pertaining to the luminaire and its mounting accessories and ‘wind load’ corresponding to a basic wind speed of 169 kmph without any deformation or damage to the structure. Maximum deflection of the poles considering top loading ie area and weight of fuxture shall meet the requirement of BS:5649 Part VI 1982. The materials of the pole as follows : Conforming to steel of grade Yst 240. Base Plate steel of grade:- E250 Conforming to IS 226/ IS 2062, Foundation Bolts:- 4.6 Gr. As per IS 1367. The pole shaft structure shall be hot dip galvanized through single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns. No mechanical operation, such as welding, drilling, etc. should be carried out on the pole structure post hot dip galvanizing. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. The poles shall be coated with epoxy zinc coated primer and finished using enviromentally stable polyurethene based paint (Marine grade paint) to minimum average DFT of 70 microns. Door opening :- The Decorative poles shall have door of approximate 300 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Electrical Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. The color of the pole shall be RAL 7037. Refer Drawing No. TCE.11364A-EL-4026-GL-40029 and Technical Specification for details. The makes of Poles shall be like Keslec, Neri, Bajaj, K-lite or as per the above specification and as approved by Chief Technical Officer (CTO). 8m Pole (Clear height) with inbuilt Junction box :- Size of pole: Bottom Diameter :The pole shall have Cast Iron Base with Pipe Dia of 165 mm OD X 4.5 mm Thickness 3 Mtr, made up of split construction, 101 mm OD X 3.25 mm Thickness 5 Mtr with Ornamental Cast Iron Decorative Ring, Decorative Cascade Bracket of minimum 950 mm long mounted on Pole with same specification as that of Pole;Junction box: 6 MCB & Terminals for mounting inside base compartment of Pole. Base Plate Dimensions :- (L x B x 320 x 320 x 16, Foundation Bolt Size :- (no. x dia.) 4 x 24 Dia, Pitch Circle Dia.:- (PC 300, Bolt Length:- 500 mm, P Anchor plate thickness :- 4.5 mm.

388

-

-

... More
Decorative Street Light Pole with Single Arm Bracket- Supply, installation, testing and commissioning of following type of Decorative Chatsworth Street Light Pole with Decorative Cascade Bracket suitable for Pendant type street lighting luminaires (Single side). The architecturally designed pole shall be structurally sound. The pole shaft shall have swaged/ tubular cross section and shall be continuously tapered with single longitudinal welding. All pole sections are swaged and joined together using high end MIG welding process and tested for its quality through NDT method, such as DP Test. All decorative pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. Batch test reports for chemical and mechanical properties of material should be submitted along with the bid. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The decorative poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The decorative pole shall be of ‘composite’ construction designed to withstand specified ‘dead load’ pertaining to the luminaire and its mounting accessories and ‘wind load’ corresponding to a basic wind speed of 169 kmph without any deformation or damage to the structure. Maximum deflection of the poles considering top loading ie area and weight of fuxture shall meet the requirement of BS:5649 Part VI 1982. The materials of the pole as follows : Conforming to steel of grade Yst 240. Base Plate steel of grade:- E250 Conforming to IS 226/ IS 2062, Foundation Bolts:- 4.6 Gr. As per IS 1367. The pole shaft structure shall be hot dip galvanized through single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns. No mechanical operation, such as welding, drilling, etc. should be carried out on the pole structure post hot dip galvanizing. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. The poles shall be coated with epoxy zinc coated primer and finished using enviromentally stable polyurethene based paint (Marine grade paint) to minimum average DFT of 70 microns. Door opening :- The Decorative poles shall have door of approximate 300 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Electrical Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. The color of the pole shall be RAL 7037. Refer Drawing No. TCE.11364A-EL-4026-GL-40029 and Technical Specification for details. The makes of Poles shall be like Keslec, Neri, Bajaj, K-lite or as per the above specification and as approved by Chief Technical Officer (CTO). 8m Pole (Clear height) with inbuilt Junction box :- Size of pole: Bottom Diameter :The pole shall have Cast Iron Base with Pipe Dia of 165 mm OD X 4.5 mm Thickness 3 Mtr, made up of split construction, 101 mm OD X 3.25 mm Thickness 5 Mtr with Ornamental Cast Iron Decorative Ring, Decorative Cascade Bracket of minimum 950 mm long mounted on Pole with same specification as that of Pole;Junction box: 6 MCB & Terminals for mounting inside base compartment of Pole. Base Plate Dimensions :- (L x B x 320 x 320 x 16, Foundation Bolt Size :- (no. x dia.) 4 x 24 Dia, Pitch Circle Dia.:- (PC 300, Bolt Length:- 500 mm, P Anchor plate thickness :- 4.5 mm.

337

-

-

... More
Decorative Street Light Pole with Single Arm Bracket- Supply, installation, testing and commissioning of following type of Decorative Chatsworth Street Light Pole with Decorative Cascade Bracket suitable for Pendant type street lighting luminaires (Single side). The architecturally designed pole shall be structurally sound. The pole shaft shall have swaged/ tubular cross section and shall be continuously tapered with single longitudinal welding. All pole sections are swaged and joined together using high end MIG welding process and tested for its quality through NDT method, such as DP Test. All decorative pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. Batch test reports for chemical and mechanical properties of material should be submitted along with the bid. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The decorative poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The decorative pole shall be of ‘composite’ construction designed to withstand specified ‘dead load’ pertaining to the luminaire and its mounting accessories and ‘wind load’ corresponding to a basic wind speed of 169 kmph without any deformation or damage to the structure. Maximum deflection of the poles considering top loading ie area and weight of fuxture shall meet the requirement of BS:5649 Part VI 1982. The materials of the pole as follows : Conforming to steel of grade Yst 240. Base Plate steel of grade:- E250 Conforming to IS 226/ IS 2062, Foundation Bolts:- 4.6 Gr. As per IS 1367. The pole shaft structure shall be hot dip galvanized through single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns. No mechanical operation, such as welding, drilling, etc. should be carried out on the pole structure post hot dip galvanizing. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. The poles shall be coated with epoxy zinc coated primer and finished using enviromentally stable polyurethene based paint (Marine grade paint) to minimum average DFT of 70 microns. Door opening :- The Decorative poles shall have door of approximate 300 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Electrical Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. The color of the pole shall be RAL 7037. Refer Drawing No. TCE.11364A-EL-4026-GL-40102 and Technical Specification for details. The makes of Poles shall be like Keslec, Neri, Bajaj, K-lite or as per the above specification and as approved by Chief Technical Officer (CTO). 7m Pole (Clear height) with inbuilt Junction box :- Size of pole: Bottom Diameter :The pole shall have Cast Iron Base with Pipe Dia of 165 mm OD X 4.5 mm Thickness 2 Mtr, made up of split construction, 89 mm OD X 3.25 mm Thickness 5 Mtr with Ornamental Cast Iron Decorative Ring, Decorative Cascade Bracket of minimum 950 mm long mounted on Pole with same specification as that of Pole;Junction box: 6 MCB & Terminals for mounting inside base compartment of Pole. Base Plate Dimensions :- (L x B x 300 x 300 x 14, Foundation Bolt Size :- (no. x dia.) 4 x 22 Dia, Pitch Circle Dia.:- (PC 300, Bolt Length:- 500 mm, P Anchor plate thickness :- 4.5 mm.

962

-

-

... More
Decorative Street Light Pole with Single Arm Bracket- Supply, installation, testing and commissioning of following type of Decorative Chatsworth Street Light Pole with Decorative Cascade Bracket suitable for Pendant type street lighting luminaires (Single side). The architecturally designed pole shall be structurally sound. The pole shaft shall have swaged/ tubular cross section and shall be continuously tapered with single longitudinal welding. All pole sections are swaged and joined together using high end MIG welding process and tested for its quality through NDT method, such as DP Test. All decorative pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. Batch test reports for chemical and mechanical properties of material should be submitted along with the bid. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The decorative poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The decorative pole shall be of ‘composite’ construction designed to withstand specified ‘dead load’ pertaining to the luminaire and its mounting accessories and ‘wind load’ corresponding to a basic wind speed of 169 kmph without any deformation or damage to the structure. Maximum deflection of the poles considering top loading ie area and weight of fuxture shall meet the requirement of BS:5649 Part VI 1982. The materials of the pole as follows : Conforming to steel of grade Yst 240. Base Plate steel of grade:- E250 Conforming to IS 226/ IS 2062, Foundation Bolts:- 4.6 Gr. As per IS 1367. The pole shaft structure shall be hot dip galvanized through single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns. No mechanical operation, such as welding, drilling, etc. should be carried out on the pole structure post hot dip galvanizing. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. The poles shall be coated with epoxy zinc coated primer and finished using enviromentally stable polyurethene based paint (Marine grade paint) to minimum average DFT of 70 microns. Door opening :- The Decorative poles shall have door of approximate 300 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Electrical Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. The color of the pole shall be RAL 7037. Refer Drawing No. TCE.11364A-EL-4026-GL-40104 and Technical Specification for details. The makes of Poles shall be like Keslec, Neri, Bajaj, K-lite or as per the above specification and as approved by Chief Technical Officer (CTO). 6m Pole (Clear height) with inbuilt Junction box :- Size of pole: Bottom Diameter :The pole shall have Cast Iron Base with Pipe Dia of 140 mm OD X 4.5 mm Thickness 2Mtr, made up of split construction, 76 mm OD X 3.25 mm Thickness 4 Mtr with Ornamental Cast Iron Decorative Ring, Decorative Cascade Bracket of minimum 950 mm long mounted on Pole with same specification as that of Pole;Junction box: 6 MCB & Terminals for mounting inside base compartment of Pole. Base Plate Dimensions :- (L x B x 250 x 250 x 14, Foundation Bolt Size :- (no. x dia.) 4 x 22 Dia, Pitch Circle Dia.:- (PC 300, Bolt Length:- 500 mm, P Anchor plate thickness :- 4.5 mm.

807

-

-

... More
Decorative Light Fixture (75 Watt)- Supply, installation, testing and commissioning of following type of 75W LED Decorative Pendant type of Luminaires, BIS approved ( alongwith BIS certification of model streetlight family confirming to IS 10322/IEC60598 & LM79 parameters as per tender specs) for Urban lighting, body made of painted spun aluminium with Top spun aluminium minimum thickness of 1.5 mm, Dia should not exceed 435 mm and height should not exceed 265, dia should not exceed 595 mm, height should not exceed 40 mm and weight should not be less than 1 kg.Body of the fixture must be in two parts and fixture opening of the fixture is from front side for the ease of operation . The protector is made of single piece injection moulded polycarbonate with thickness of 3 mm and weight should not exceed 1 kg. Diamteter and height of the protector should not be more than 320 mm. Protector grade with UV resistant IK 09 ( Confirmed by IEC60598 report from Third party NABL approved lab) Protector holding spun with a thickness of 3 mm with a minimum diameter of 420 mm and weight more than 0.3 kg. ring Permanently sealed optical compartment with IP66 protection.( Confirmed by IEC60598 report from Third party NABL approved lab). Luminaire offers tool free access to gear compartment with IP65 protection( Confirmed by IEC60598 report from Third party NABL approved lab) Foam gasket for control gear assembly with minimum sixe of 18*12.Minimum Luminaire dimensions of 545* 550 mm. Luminaire can be installed as a suspended luminaire with 1 inch BSP stainless steel pipe with 2 chuck nuts is provided..The luminaire must be provided with Air vent plug in optical compartment.The luminaire is equipped with PMMA lenses with wide photometry for increased pole spacing. The luminaire is provided with disconnector to avoid electrical shocks. Easy access to control gear compartment by opening special draw latch with zinc plated material and hinge kind of arrangement. Fixture is having external surge protection of 10KV. Electronic driver is having power factor0.90*, THD15*%, CRI80 and input voltage range from 120-227V AC at 50Hz. Minimum lumen 9000 lumen and system efficacy of minimum 120 lm/watt (Confirmed by LM79 report from Third party NABL approved lab) in CCT range of 3000K4000K/5500K as per ANSI. presented with Dialux report and IES file of the luminaire System life of 50000 burning hours with 70% of initial lumens maintainedLuminaire is suitable for operating temperature (Ta) from -10° to 50°C. Driver can withstand 320V AC for 48 hours and 360 V AC for 2 hours. Refer Technical Specification for details. The Color Temperature range shall be decided by Chief Technical Officer (CTO) at the time of execution of work. 75W LED Pendant type lumaries similar to Keselec Porto-NU-75 Suspended for Street lighting or equivalent product of Neri Light 21, Schreder, Philips (Signify), Bajaj, Havells or as per the above specification and as approved by Chief Technical Officer (CTO).

1113

-

-

... More
Decorative Light Fixture (60 Watt)- Supply, installation, testing and commissioning of following type of 60W LED Decorative Pendant type of Luminaires, BIS approved (alongwith BIS certification of model streetlight family confirming to IS 10322 & LM79 parameters as per specification) for Urban lighting. Body made of painted spun aluminium with Top spun aluminium minimum thickness of 1.5 mm, Dia should not exceed 435 mm and height should not exceed 265 mm, weight should not be less than 1.35 kg and Lower spun aluminium of minimum thickness of 1.5 mm, dia should not exceed 595 mm, height should not exceed 40 mm and weight should not be less than 1 kg. Body of the fixture must be in two parts and fixture opening of the fixture is from front side for the ease of operation . The protector is made of single piece injection moulded polycarbonate with thickness of 3 mm and weight should not exceed 1 kg. Diamteter and height of the protector should not be more than 320 mm. Protector grade with UV resistant IK 09 ( Confirm by IS10322 report from Third party NABL approved lab) Protector holding spun with a thickness of 3 mm with a minimum diameter of 420 mm and weight more than 0.3 kg. ring Permanently sealed optical compartment with IP66 protection.( Confirmed by IS10322 report from Third party NABL approved lab). Luminaire offers tool free access to gear compartment with IP65 protection (Confirmed by IS10322 report from Third party NABL approved lab) Foam gasket for control gear assembly with minimum sixe of 18*12.Minimum Luminaire dimensions of 545* 550 mm . Luminaire can be installed as a suspended luminaire with 1 inch BSP stainless steel pipe with 2 chuck nuts is provided. The luminaire must be provided with Air vent plug in optical compartment.The luminaire is equipped with PMMA lenses with wide photometry for increased pole spacing. The luminaire is provided with disconnector to avoid electrical shocks. Easy access to control gear compartment by opening special draw latch with zinc plated material and hinge kind of arrangement. The luminaire shall be provided with Inbuilt auto cutoff arrangement to save from abnormal power fluctuation. The fixture shall have external surge protection of 10KV. Electronic driver is having power factor0.90*, THD15*%, CRI80 and input voltage range from 120-227V AC at 50Hz. Minimum lumen 7200 lumen with minimum system efficacy of 120 lm/watt (Confirmed by LM79 report from Third party NABL approved lab) in CCT range of 3000/4000/5500 as per ANSI. presented with Dialux report and IES file of the luminaire, System life of 50000 burning hours with 70% of initial lumens maintained. Lighting level to be achieved with Avg lux 20 ,Min/avg- 50% and Min/Max- 33%.Colour temperature will be decided at the time of execution. Luminaire is suitable for operating temperature (Ta) from -20° to 50°C. Driver can withstand 320V AC for 48 hours and 360 V AC for 2 hours. Refer Technical Specification for details. The Color Temperature range shall be decided by Chief Technical Officer (CTO) at the time of execution of work. 60W LED Pendant type lumaries similar to Keselec Porto-NU-60 Suspended for Street lighting or equivalent product of Neri Light 21, Schreder, Philips (Signify), Bajaj, Havells or as per the above specification and as approved by Chief Technical Officer (CTO).

962

-

-

... More
Decorative Light Fixture (40 Watt)- Supply, installation, testing and commissioning of following type of 40W LED Decorative Pendant type of Luminaires, BIS approved (alongwith BIS certification of model streetlight family confirming to IS 10322 & LM79 parameters as per tender specs) for Urban lighting, body made of painted spun aluminium with Top spun aluminium minimum thickness of 1.5 mm, Dia should not exceed 435 mm and height should not exceed 265 mm, weight should not be less than 1.35 kg and Lower spun aluminium of minimum thickness of 1.5 mm, dia should not exceed 595 mm, height should not exceed 40 mm and weight should not be less than 1 kg. Body of the fixture must be in two parts and fixture opening of the fixture is from front side for the ease of operation .The protector is made of single piece injection moulded polycarbonate with thickness of 3 mm and weight should not exceed 1 kg. Diamteter and height of the protector should not be more than 320 mm. Protector grade with UV resistant IK 09 ( Confirm by IS10322 report from Third party NABL approved lab) Protector holding spun with a thickness of 3 mm with a minimum diameter of 420 mm and weight more than 0.3 kg. ring Permanently sealed optical compartment with IP66 protection.( Confirmed by IS10322 report from Third party NABL approved lab). Luminaire offers tool free access to gear compartment with IP65 protection( Confirmed by IS10322 report from Third party NABL approved lab) Foam gasket for control gear assembly with minimum sixe of 18*12.Minimum Luminaire dimensions of 545* 550 mm . Luminaire can be installed as a suspended luminaire with 1 inch BSP stainless steel pipe with 2 chuck nuts is provided. The luminaire must be provided with Air vent plug in optical compartment.The luminaire is equipped with PMMA lenses with wide photometry for increased pole spacing. The luminaire is provided with disconnector to avoid electrical shocks. Easy access to control gear compartment by opening special draw latch with zinc plated material and hinge kind of arrangement. The luminaire shall be provided with Inbuilt auto cutoff arrangement to save from abnormal power fluctuation. The fixture shall have external surge protection of 10KV. Electronic driver is having power factor0.90*, THD15*%, CRI80 and input voltage range from 120-227V AC at 50Hz. Minimum lumen 4800 lumen with minimum system efficacy of 120 lm/watt (Confirmed by LM79 report from Third party NABL approved lab) in CCT range of 3000/4000/5500 as per ANSI. presented with Dialux report and IES file of the luminaire, System life of 50000 burning hours with 70% of initial lumens maintained. Lighting level to be achieved with Avg lux 20 ,Min/avg- 50% and Min/Max- 33%.Colour temperature will be decided at the time of execution. Luminaire is suitable for operating temperature (Ta) from -20° to 50°C. Driver can withstand 320V AC for 48 hours and 360 V AC for 2 hours. Refer Technical Specification for details. The Color Temperature range shall be decided by Chief Technical Officer (CTO) at the time of execution of work. 40W LED Pendant type lumaries similar to Keselec Porto-NU-40 Suspended for Street lighting or equivalent product of Neri Light 21, Schreder, Philips (Signify), Bajaj, Havells or as per the above specification and as approved by Chief Technical Officer (CTO).

807

-

-

... More
Architectural Pedestrian Post Top Pole (3.5 Meter Long)- Supply, installation, testing and commissioning of 3.5M decorative Pole Made in combination of mild steel pipe sections 89mm dia.x3mm thick(minimum) & 76mm dia.x3mm thick(minimum). Decorative Cast iron Base design with the company/brand logo engraved in the cast iron mould, starting with dia 260mm for 130mm height, followed by a ring of 260 dia gradually tapering to a flat round surface of dia 170mm for 366mm height again followed by a ring dia 210mm and gradual tapering upto a dia 92mm as approved by the econerned Engineer the total height of decorative cast iron base is 700mm and weight-32kgs. Decorative cast iron base should be provided with a flush door of length 228mm, width 124mm and height 30mm.Top ring (140mm dia.x140mm(H)-2.75kgs.) made of cast iron. All cast iron weights mentioned are with +/-5% tolerance.Entire pole shall be made to provide pleasing aesthetics as approved by Concerned Engineer in-charge. After Fabrication, Entire Pole is hot dip galvanized(60 microns Minimum ) for the effective corrosion resistance . The hot dip Galvanised pole should be provided with an inbuilt junction box to fix 32A connectors and 6A MCB, at the bottom - the inbuilt box should have a flush door of suitable size. The decorative pedastal to be mounted on a suitable size steel plate. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the RCC foundation. The wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole design. Pole & Cast iron parts are Akzonobel painted in 3 layer coating(coating thickness-200 microns minimum) in which 1st layer with etch primer(Interprime 539), 2nd layer with epoxy primer(Intercure 200HS) & 3rd final layer with PU paint(Interthane)- customised colour Metallaic Grey. Refer Technical Specification for details. Refer Drawing No. TCE.11364A.EL-4026-GL-40032. The makes of Pole shall be like Neri Make Model No JM.06.18.010/BEGA/GHM or equivalnet product of Keslec, Bajaj, K-lite or or as per the above specification and as approved by Chief Technical Officer (CTO).

146

-

-

... More
Architectural LED Post Top Fixture (25 Watt)- Supply, installation, testing and commissioning of 25 Watt LED Post Top Fixture, 3000 K/ 4000 K. Upper square frame of light shall be in single piece and made of die cast aluminum using pressure die-casting process, with a decorative element which is also made of die cast aluminum using pressure die-casting process, fixed on the top. Auxiliary and optical compartment can be accessed by tilting the top frame. Bottom frame in single piece, made of die cast aluminum using pressure die-casting process with a four-armed bracket with flange, which is also made of die cast aluminum using pressure die-casting process, fixed at the bottom. Frosted Screen made of polymethylmethacrylate (PMMA) molded in a single piece using Injection molding process. Screen's Impact resistance: IK06. Pure polyester powder coating in Standard Grey Colour. IP Rating - IP 66. Height – 605mm, Length - 325mm, Width - 325mm,Weight - 6Kg, Area Exposed to Wind(S) - 0.15 m2. Power LED's Module (with CREE/NICHIA- Individual LED's Minimum Luminous Flux (lm) is 130lm @ 350 mA (@ 85 °C) same should be supported by LED manufacturer's tech sheet) in compliance with IEC 62031 (Supporting Test Report from UL Authorised Laboratory should be submitted), on Printed Circuit Board with metal core plate. Colour Rendering Index: Ra 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection of 10 KV in built in the fixture. Optics with refractive lens in PC (Polycarbonate), UV Resistant & Shock Resistance-IK10. LM80 Reported LED Lifetime is L90@ 50,000 hours minimum & Estimated LED Lifetime is L80 @ 100,000 hours(Ta-25°C) minimum. The Light fixture shall be in compliance with IEC 60598-2-3; IEC 60598-1. Refer Technical Specification for details. The makes of Light Fixture shall be like Neri Make Model No LIGHT 851-25-W Power Module LED BEGA/GHM or equivalent product of Keslec, Bajaj, Schreder, Philips (Signify), Havells or or as per the above specification and as approved by Chief Technical Officer (CTO).

146

-

-

... More
Pole Founadation (8 Mtr Pole)- Providing and laying Reinforced cement concrete for construction of Street Light pole foundation at all locations, including excavation in all type of soils for depth as per tender drawing, the cost of providing steel reinforcement, bending, binding and placing in position, centering and shuttering with all leads, lifts and depths true to level and position etc. complete including necessary tools, plants, machinery and all related operations as required to complete the pole foundation work to the satisfaction of Engineer-in-charge. Material specifications and other details shall be as per tender drawing . Refer Drawing No.TCE.11364A-EL-4026-GL-40012 for details.

725

-

-

... More
Pole Founadation (6 & 7 Mtr Pole)- Providing and laying Reinforced cement concrete for construction of Street Light pole foundation at all locations, including excavation in all type of soils for depth as per tender drawing, the cost of providing steel reinforcement, bending, binding and placing in position, centering and shuttering with all leads, lifts and depths true to level and position etc. complete including necessary tools, plants, machinery and all related operations as required to complete the pole foundation work to the satisfaction of Engineer-in-charge. Material specifications and other details shall be as per tender drawing . Refer Drawing No.TCE.11364A-CV-3000-RC-30007 for details.

1769

-

-

... More
Pole Founadation (3.5 Mtr Pole)- Providing and laying Reinforced cement concrete for construction of Street Light pole foundation at all locations, including excavation in all type of soils for depth as per tender drawing, the cost of providing steel reinforcement, bending, binding and placing in position, centering and shuttering with all leads, lifts and depths true to level and position etc. complete including necessary tools, plants, machinery and all related operations as required to complete the pole foundation work to the satisfaction of Engineer-in-charge. Material specifications and other details shall be as per tender drawing.

146

-

-

... More
LT Cable- Supply, laying, testing & commissioning of 1.1 kV grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS:7098 (Part-1) & IEC:60502 (Part-1) of following sizes. The makes of cable shall be like RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 4C x 16 sq mm A2XFY armoured AL Cable

83837

-

-

... More
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. The makes of cable lugs shall be like Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO) . 4C x 16 sq mm A2XFY armoured AL Cable

3260

-

-

... More
Providing and, fixing heavy duty flange type Double Compression Brass Cable Gland (Nickel Plated) with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. The makes of cable gland shall be like Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 4C x 16 sq mm A2XFY armoured AL Cable

412

-

-

... More
Supply, installation, testing and commissioning of 3C X 2.5 Sqmm flexible Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988. The makes of cable shall be like RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO).

23233

-

-

... More
Supply, installation, testing and commissioning of Termination of 3C X 2.5 Sqmm flexible Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988. The makes of cable lugs shall be like Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO).

4919

-

-

... More
Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.

1611.6

-

-

... More
Supply and Laying of 25X6mm GI strip at a depth of 0.5m below ground as strip earth electrode, including termination/ interconnecting with GI Nut/Bolts, washer, Spring washer etc. as required. Jointing shall be done by overlapping & with two sets of Nut/ bolts and spring washer spaced at 50mm apart for earthing of the Street light panels.

1361.6

-

-

... More
Supply, installation & testing of Earthing with GI Pipe 4.5 Meter Long, 40 mm dia including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe etc. (Without charocal and salt) as per directions of Engineer in charge and as specified in technical specification.

2802

-

-

... More
SITC of Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene (conforming to IS 14930 II) with necessary connecting accessories of same material at required depth for laying of cable below ground/ road surface for enclosing cable and back filling the same to make ground as per original. The makes of DWC Pipe shall be like Duraline, Rex or as approved by Chief Technical Officer (CTO). 50 MM ID

77053

-

-

... More
Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making the surface as normal ground.

77053

-

-

... More
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable (16 bricks per meter)

77053

-

-

... More
Making trench in Hard Murum/Tar Road of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making the surface as normal ground.

77053

-

-

... More
STREET LIGTHT FEEDER PILLAR (SLFP)- S.I.T.C. of Feeder Pillar (Outdoor) totally enclosed type as per IS: 2147, Operation on 3-Phase, 415V, 50Hz, Neutral effectively grounded, IP-55, with power & control contactors as per IS: 13947, CT of accuracy class- I as per IS: 2705, suitable rating of incoming & outgoing feeders as per specification, digital type metering instruments, equipment fittings, bus bars, cable gland, incoming & ougoing cable connection chamber suitable for 1100V grade, Al./ Cu. conductor PVC insulated & PVC sheathed armoured cable, 10% spare terminals, power wiring use of 650/ 1100V grade, FRLS insulated copper conductor wires conforming to IS: 694 & 8130, cable compartments of minimum 350 mm size, detail specifications & data sheet including required testing @ factroy as per applicable IS/ IEC standards. Feeder Pillar shall be comprising of: a) Incomer of Four pole moulded case circuit breaker (MCCB) having breaking capacity ICU of 25 K.A. at 415 V having normal current rating of 63A with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s complete erected as directed with necessary earth wire, voltmeter, VSS and R,Y,B indication lamp. (1 No.) b) Outgoing of Three Phase 415 V, Four Pole, RCBO, 30 mA & confirms to IS :12640 in existing box having 32A capacity.(6 Nos.) c) Supplying and erecting of 100 A triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm duly wrapped with colour insulating tape for phase sequence. d) Providing & erecting weather proof, dust & vermin proof, floor mounted front operated outdoor type cubical panel board having IP-55 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. (Minimum 350mm Depth) NB: 1. Price of Panel comprises of pedestrial of minimum 350 mm height made of MS angle/ channel/ flats of favourable shapes. 2. Incomer shall be equiped with Power Contactor & Astronomical time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.

63

-

-

... More
Dismentling Charges of existing LED Street Light Fixtures of various wattages with Bracket & Street Light Poles, cables complete without damaging them in any manner and carrying, handling & shifting each component to a designated place as specified and directed by the department.

1386

-

-

... More
Dismantling & Re-installation of High Mast- Dismentling Charges of existing High Mast of height ranges from 10 M to 16 M with LED Light Fixtures of various wattages with Mounting Ring, Bracket, Winch, Raising & Lowering System, Cables, Feeder Pillar complete without damaging them in any manner and carrying, handling & shifting each component to proper place and reinstallation of the same LED Luminaires, High mast and other accessories including Feeder Pillar on newly constructed Foundation as specified & directed by the department and make it operational as earlier.

12

-

-

... More
Providing and fixing of M.S Round holding down or Anchor bolts with Nuts and Washer plates complete.

915.4

-

-

... More
High Mast Foundation- Construction of shallow foundation with M20 grade concrete for the High mast considering the safe soil bearing capacity at site as 10 T/ Sqmtr at appropriate depth with all materials and labours as directed and specified.

12

-

-

... More
24x7 Water Supply System

-

-

-

... More
Submission and approval of survey of Total Station or GTS survey from GTS Bench Mark to Project area including soil investigations designs , working Drawings including all layout sections, typical details, shop drawings, As-built drawings and submission of working drawings and implementation schedule as per priority given by Engineer-In-Charge for approval obtaining approval from competent authority before commencement of work , etc. complete.

1

-

-

... More
5 LL ESR vegetable market:(B) Providing and applying epoxy paint for pipeline and snowcem waterproof cement paint of approved make for concrete surface to 5 LL ESR near vegetable market including cleaning the surface by scrapping and air blower to the satisfaction of Engineer in charge necessary scaffolding etc complete with all leads and lifts satisfactory hydraulic test water tightness test as per IS for old surface two coats - For External painting- Approved make FOSROC, BASF, SIKA or as approved by Chief Technical Officer (CTO)

2000

-

-

... More
Providing and fixing in position Acid and alkali resistant tiles for flash mixture and alum dosing tank including acid resistant plaster etc. complete. 15 mld plant-Acid and alkali resistant tiles 300x300 mm size, 10 mm thick Approved make Choramandalam, Rustile, Arcoy, Perfect Acid Wares/ Mahakoshal Potteries/ Champion or as approved by Chief Technical Officer (CTO).

150

-

-

... More
15 MLD WTP: Providing and fixing to wall, ceiling and floor, galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(C) 25mm (up-to 10 ton) Approved make Riddhi Steel & Tubes (P) Ltd,Ahmedabad, M/s. Surya Roshni Limited, Kutch or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Pump House at 15 MLD WTP for 11 LL ESR & 12 LL ESR -Designing (Aesthetically) and construction of R.C.C frame structure of pump house of pump room with positive suction and negative suction. With Gantry Structure (Min. Height 4.5 M) Upto 6.00 M (Floor to Ceiling Level) - Note: Minimum 15 % opening for ventilation should be provided in pump room rolling shutter, door and windows of aluminium section and window grill of iron should be provided.

123.3

-

-

... More
Neutralization Pit cum Tank - (6 M x 1.7M x 0.8M)-Excavation for base slab or breaking of existing base slab cum raft including. all safety provisions using site rails and stacking excavated stuff up to a lead of 90 mts. cleaning the site etc. complete for lifts and strata as specified. Soft rock / masonry in hard rock & CC1:2:4.

4.6

-

-

... More
Neutralization Pit cum Tank - P.C.C. M -10 leveling Course.-Providing and casting in situ mass cement concrete in grade M-10 (Approx. Corresponding to proportion. 1:3:6) using granite quartize trap metal of size 12mm to 25 mm incl. Consolidation curing etc. Complete. Without Form Work

1.5

-

-

... More
Neutralization Pit cum Tank -RCC Works - CC M-30 Control Concrete for Water Retaining Structures-Providing and cast in situ C.C. in grade M-30 proportions of ingradients as per mix design by weigh batching using granite, quartzite trap metal of size 12mm to 20mm and /or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation, curing and hydraulic testing etc. complete (excluding cost of reinforcement) up to 6 meter height /depth Av. G.L.for all ,Water retaining structures-.For Raft / Base Slab with Shuttering,

1.3

-

-

... More
Neutralization Pit cum Tank - RCC Works - CC M-30 Control Concrete for Water Retaining Structures-Providing and cast in situ C.C. in grade M-30 proportions of ingradients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and /or 6 mm to 12 mm including scaffolding cantering formwork, needle vibrated consolidation, curing and hydraulic testing etc. complete (excluding cost of reinforcement) up to 6 meter height /depth Av. G.L.for all ,Water retaining structures.Vertical Wall of 0.2 M thickness,

2.7

-

-

... More
Neutralization Pit cum Tank -Supplying, cutting, bending, binding and placing in position steel as per plan and design and as Per ISS 2502 including cost of steel and binding wire for reservoirs / structures only including lift up to 6 meter height or depth below G.L. for all diameters. 2% of Concrete in Slab and Vertical. Wall

0.6

-

-

... More
Neutralization Pit cum Tank - Cement plaster 20 mm thick in cm 1:2 using water proofing compound of approved quality including finishing etc complete. as directed by Engineer-In-Charge. For Base Slab and Side wall

10.2

-

-

... More
Square Bar for Rail for Intake Well 15 MLD-Providing, detailing, fabricating and fixing at desired location using hot rolled sections and MS Plates of grade Fe250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), transporting to site and erecting structural steel members for all heights & at all levels including provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary fixtures and operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding and removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30microns after fabrication including touching up with spray painting after re-erection etc complete as directed by Engineer In Charge. (The qty. for this item shall be measured for gusset plates, base plates, bolts in M.T.) Providing and fixing Square Bar of size- 50 mm x30mm over steel beam for rail track (11.8 kg/m) Approved make M/s. Shah Alloys Ltd., Gandhinagar,M/s. Welspun Corp Ltd, Anjar or as approved by Chief Technical Officer (CTO).

1100

-

-

... More
Providing and fixing Chain Pulley-Manual-2T capacity Chain pulley as per standard specification and as directed by Engineer in charge.

1

-

-

... More
Providing and fixing in position Trolley for Pump - 2T or more capacity rail trolley as per standard specification and as directed by Engineer in charge.

2

-

-

... More
Excavation in any soil upto 30 cm. depth, braking clods, removing unwanted stuff such as brick bats, stones, grass roots etc. refilling the same, preplanting watering , weeding .top - digging, relevelling and bringing the earth to fine tilth, ready for sowing or planting.

5837.6

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).

5837.6

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment). (5 cum / 100 sqm)

912.6

-

-

... More
Rough dressing the trenched ground including breaking clods including all the labour charges and as directed by Engineer-In-Charge.

18087.5

-

-

... More
Fine dressing of the ground including all the labour charges and as directed by Engineer-In-Charge etc complete.

18087.5

-

-

... More
Labour for Spreading and mixing the manure evenly with top 8 to 10 C.M of Prepared area at the rate of 5 cu.m per 100 sq.m area

1500

-

-

... More
Providing pure doob (Dharo) Grass Suckers and Planting the same at a distance of 8 to 10 cm.both ways and maintaining the same till well established (about 45 days)

10365

-

-

... More
Excavation pits of 60 cm. x 60 cm. x 60 cm. size at specified spots for tree plantation as directed by Engineer in charge etc complete.

65

-

-

... More
RAISING FLOWER BEDS OR LIVE EDGING : After excavating soil up to 30 cm. preparing soil for planting by supplying and mixing Farm Yard Manure at the rate of 5 cu.m per 100 sq.mt area, providing & planting well grown seedlings of specified varieties at proper distance and maintaining till well established (about 45 days) complete.

10000

-

-

... More
PLANTING TREES AND SHRUBS : After excavating pits of the size 60 cm x 60 cm x 60 cm. refillings the same by providing and mixing Farm Yard Manure at the rate of 0.06 cu.m per pit, providing and planting well grown sapling of specified variety and maintaining till well established. Tree height 2.5 to 3 feet and Shrub height 1.5 to 2.0 feet. Bag size 8'x10' (about 45 days) complete.

65

-

-

... More
Supply of the Labour for Maintenance of Garden Scope of work .(1) Cleaning of the Garden.(2) Removal of any Unwanted Growth from the Lawn (3) Triming and Cutting of Excess Growth of any Tree in the Garden (4) Watering the Entire Garden including Lawn and Plantation.(5) Clean of Existing Structure in the garden.(6) Maintenance Up Keep of Play Area.

65

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.

116

-

-

... More
60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern , Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade concrete as per approved design and including excavation for fixing in proper line and level, filling the joint with C:M 1:3 (1cement:3fine sand) etc. complete. (upto 10 ton)

116

-

-

... More
Supply and fixing including all labour charges of DELONIX REGIA (gulmohar) of Bag size 18"x18", as directed by Engineer In Charge, etc complete.

27

-

-

... More
Supply and fixing including all labour charges of PLUMERIA ASSORTED VARITIES (Champa) of Bag size 18"x18", as directed by Engineer In Charge, etc complete.

10

-

-

... More
Supply and fixing including all labour charges of SAMANEA SAMAN (Rain tree) of Bag size 18"x18", as directed by Engineer In Charge, etc complete.

28

-

-

... More
Providing, fixing, testing and commissioning of sprinkler and drip system for irrigation at WTP 4,15 and 11mld landscaping area.Approved make Jain Irrigation or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-In all sorts of soil and soft murrum.

19635.2

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-In hard murrum, boulders incl. macadam road and In soft rock and/or masonry in CM or L M or Lime Concrete.

9817.6

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-In hard rock and / or in C. C. 1:2:4 or RCC with breaking, chiseling, or by chiseling / breaking only (Blasting Prohibited).

9817.6

-

-

... More
Extra for excavating trenches for pipes, cables, etc. in ordinary / hard rock exceeding 1.5m in depth but not exceeding 3m. (Rate us over correspond basic item for depth up to 1.5m)

791.4

-

-

... More
Dewatering in all sorts of soil and soft murrum, hard Murrum and boulders, Soft Rock, Hard Rock, up to 1.5 mt. depth from G.L.-Depth not exceeding 1.5m

1000

-

-

... More
Providing bedding including. ramming, watering, levelling, consolidating etc. Complete as per standard and instruction of engineer-in-charge. (As above with selected excavated earth available near site)

3440.8

-

-

... More
Refilling the pipeline trenches including ramming, watering, consolidating disposal of surplus stuff as directed within a radius of 3 km.-Refilling as directed by Engineer in charge.

22712.5

-

-

... More
Refilling the pipeline trenches including ramming, watering, consolidating disposal of surplus stuff as directed within a radius of 3 km-with selected soil brought from outside including all lead and lift etc. complete.

5678.1

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). -150MM DIA & Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

3712.8

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). 200mm dia Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

5623.3

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). 250mm dia pipe Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

2378.4

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). -300mm dia pipe Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

5537.4

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). 350mm dia pipe Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

220

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). 400mm dia Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

3257.1

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). -450mm dia Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

738

-

-

... More
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). Rate for DI pipe based on Wholesale Price index of Pig Iron as 114.20 for the month of Febuaury-2019-600mm dia Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

306

-

-

... More
Providing and supplying D. I. K-9 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). DI PIPE K-9 Distribution Mains -600mm dia Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

306

-

-

... More
Proposed PumpHouse at 15 MLD WTP to Dokmardi ESR:Providing and supplying D. I. K-9 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). DI PIPE K-9 Transmission Mains 450 mm dia Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO)

3500

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete.-150 mm dia

3712.8

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete.-200 mm dia.

5623.3

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete.-250mm dia.

2378.4

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete-300mm dia.

5537.4

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete-350mm dia

220

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete-400mm dia

3257.1

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete-450mm dia

4238

-

-

... More
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. complete-600 mm dia

612

-

-

... More
Manufacture, supply and delivery of 80 mm to 700 mm dia cast iron flange ended specials complete as per IS: 5531-1977 (Part- I to III) or its latest revision if any, suitable for use with A.C. Pressure pipes manufactured as per IS: 1592-1989 or its latest revision for various dia meter and classes. The delivery of specials is to be made to SSCL store or sites any where in Silvassa including all taxes, loading, carting, unloading, stacking, insurance, octroi, inspection charges etc. complete

119.6

-

-

... More
Sluice Valves-Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.Sizes in mm valves for strategic location on dist network -100 mm Dia PN-1 With hand wheel /cap operated (PD type short body) Approved make Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

41

-

-

... More
Sluice Valves-Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.Sizes in mm valves for strategic location on dist network -150 mm Dia PN-1 With hand wheel /cap operated (PD type short body) Approved make Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

16

-

-

... More
Sluice Valves-Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.Sizes in mm valves for strategic location on dist network - 200 mm Dia PN-1 With hand wheel /cap operated (PD type short body) Approved make Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

18

-

-

... More
Sluice Valves-Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. Sizes in mm valves for strategic location on dist network -250 mm Dia PN-1 With hand wheel /cap operated (PD type short body) Approved make Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Sluice Valves-Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.Sizes in mm valves including for strategic location on dist network - PN 1 - 300 mm Dia PN-1 With hand wheel /cap operated (PD type short body) Approved make Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

5

-

-

... More
Sluice Valves-Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.Sizes in mm valves for strategic location on dist network - 350 mm Dia PN-1 With hand wheel /cap operated (PD type short body)Approved makeKirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

3

-

-

... More
Sluice Valves-Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.Sizes in mm valves for strategic location on distribution network -400 mm Dia PN-1 With hand wheel /cap operated (PD type short body)Approved makeKirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

7

-

-

... More
Sluice Valves-Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.Sizes in mm valves including for strategic location on dist network - 450 mm Dia - PN 1.6 With hand wheel /cap operated (PD type short body) Approved make Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Sluice Valves-Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.Sizes in mm valves including for strategic location on dist network -600 mm Dia - PN 1.6 With hand wheel /cap operated (PD type short body) Approved make Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

3

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilint Sluice Valves -100 mm Dia

41

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilint Sluice Valves -150 mm Dia

16

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilient Sluice Valves -200 mm Dia

18

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilient Sluice Valves -250 mm Dia

2

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilient Sluice Valves -300 mm Dia

5

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilient Sluice Valves -350 mm Dia

3

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilient Sluice Valves -400 mm Dia

7

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilient Sluice Valves -450 mm Dia

2

-

-

... More
Lowering, laying and jointing in position CI D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilient Sluice Valves -600 mm Dia

3

-

-

... More
Lowering, laying and jointing in position C. I. Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete-.DI resilient -80 mm Air Valve

7

-

-

... More
Air Valves-Providing and supplying C. I. Air valves of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.80 - Double Acting Approved make Approved make M/s. Kirloskar Brothers Ltd., M/s. VAG Valves India Pvt. Ltd. M/s IVI ltd or as approved by Chief Technical Officer (CTO).or as approved by Chief Technical Officer (CTO).

7

-

-

... More
Valve Chamber (Sluice): Construction of RCC Chamber of size 1mx1mx1.5 mD, for sluice valve including suitable size SFRC HD frame & cover, surface box, Lifting eye, with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work, PCC in M-15 grade CC of 100mm thick, all RCC work shall be in M25 grade CC, Centring and shuttering including strutting, propping etc. and removal of form work, steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, and binding all complete work, back filling available excavated earth (excluding rock), and safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 with all other requirement to make the structure operational, complete to the satisfaction of EIC.

104

-

-

... More
Valve Chamber (Air): Construction of RCC Chamber of size 1mx1mx1.3 mD, for sluice valve including suitable size SFRC HD frame & cover, surface box, Lifting eye, with inscription on Frame and cover chamber identification & owner including necessary civil & excavation work, PCC in M-15 grade CC of 100mm thick, all RCC work shall be in M25 grade CC, Centring and shuttering including strutting, propping etc. and removal of form work, steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, and binding all complete work, back filling available excavated earth (excluding rock), and safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 with all other requirement to make the structure operational, complete to the satisfaction of EIC.

7

-

-

... More
Thrust Block -Providing and cast in situ C.C. in grade M-25 proportions of ingredients as per mix design by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated consolidation, curing and hydraulic testing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. comp. up to 6 meter height /depth Av. G.L.for all water retaining structures. - Flat bottom slab/floor slab/slab with shuttering

505.2

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO)

52

-

-

... More
Bulk Water Meter Chamber - Construction of RCC Chamber of size 1mx1mx1.5mD, for sluice valve including sutaible size SFRC HD frame & cover, surface box, Lifting eye, with inscription on Frame and cover chamber identification & owner along with necessary civil & excavation work, PCC in M-15 grade CC of 100mm thick, all RCC work shall be in M25 grade CC, Centring and shuttering including strutting, propping etc. and removal of form work, steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, and binding all complete work, back filling available excavated earth (excluding rock), and safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 with all other requirement to make the structure operational, complete to the satisfaction of EIC. Size of chamber 0.90 m x 0.90 m and 1.5 mt. deep (Max) - For 1 Mtr. Extra Depth

93

-

-

... More
Road Restoration works -Breaking existing Asphalt road including all types of excavation, by mechanical means etc. complete a directed by Engineer in charge etc. complete. Breaking existing road

24555.8

-

-

... More
Road Restoration works BT road.-Providing and constructing BT road including all types of excavation cleaning and grabbing road making road surface etc. complete as mentioned in detail specification directed by Engineer in charge.

18170.9

-

-

... More
Drilling of 500 mm dia Horizontal borehole for watermain pipeline under the railway tracks, road tracks and any other utility such as Gas, Water, Sewer, OFC, etc. including all strata with required length including fixing of 400 mm dia M.S.casing pipe of minimum 6 mm thick with welding pushing etc. complete Providing & fixing various size of pipe for 193.7mm/219.10mm/244.5mm dia watermain of G.I/M.S pipe of minimum 6.3 mm thick for railway premises as per instruction & regulations of Railway authority & under supervision of Railway authority including providing, supplying & fixing of spacer at specified interval if required between Casing pipe and water main, ISI make sluice valve of required size at both side of railway boundary with construction of brick edge pavement including C:C encasing 1:3:6 in 10 mtr length of pipe at both side. Including providing & fixing of M.S/Iron Manhole frame with cover for valve chamber with lacking arrangement etc. complete with all material labour fabrication,hydralic testing of pipe & valve etc. complete for 45 mt Length. Which includes horizontal pushing and with open excavation.-MS Casing Pipe + Water Main Size-219.1mm (For 200 mm Dia. Crossings) Approved make of MS pipe Jindal, Sail, Maharashtra Seamless Ltd., Sukeli, Maharashtra or as Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

5

-

-

... More
Drilling of 600mm dia Horizontal borehole for watermain pipeline under the railway tracks including all strata with required length including fixing of 500 mm dia M.S.casing pipe of minimum 8 mm thick Or IRS Casing Pipe with welding pushing etc. complete Providing & fixing various size of pipe for 273.1mm/323.9mm/355.6 mm dia watermain of G.I/M.S pipe of minimum 6.3 mm thick for railway premises as per instruction & regulations of Railway authority & under supervision of Railway authority including Providing, supplying & fixing of spacer at specified interval if required between Casing pipe and water main, ISI make sluice valve of required size at both side of railway boundary with construction of brick edge pavement including C:C encasing 1:3:6 in 10mtr length of pipe at both side. Including providing & fixing of M.S/Iron Manhole frame with cover for valve chamber with locking arrangement etc. complete with all material labour fabrication, hydraulic testing of pipe & valve etc. complete for 45mt Length. Which includes horizontal pushing and with open excavation.MS Casing Pipe + Water Main Size-323.9mm (For 300 mm Dia. Pipe Crossings) Approved make of MS pipe Jindal, Sail, Maharashtra Seamless Ltd., Sukeli, Maharashtra or as approved by Chief Technical Officer (CTO).

3

-

-

... More
Drilling of 600 mm dia Horizontal borehole for watermain pipeline under the railway tracks including all strata with required length including fixing of 500 mm dia M.S.casing pipe of minimum 8 mm thick Or IRS Casing Pipe with welding pushing etc. complete Providing & fixing various size of pipe for 273.1mm/323.9mm/355.6mm dia watermain of G.I/M.S pipe of minimum 6.3 mm thick for railway premises as per instruction & regulations of Railway authority & under supervision of Railway authority incl Providing, supplying & fixing of spacer at specified interval if required between Casing pipe and water main, ISI make sluice valve of required size at both side of railway boundary with construction of brick edge pavement incl C:C encasing 1:3:6 in 10mtr length of pipe at both side. Incudingl providing & fixing of M.S/Iron Manhole frame with cover for valve chamber with locking arrangement etc. complete with all material labour fabrication, hydraulic testing of pipe & valve etc. complete for 45mt Length. Which includes horizontal pushing and with open excavation.-MS Casing Pipe + Water Main Size-355.6 mm (For 350 mm Dia. Pipe Crossings) Approved make of MS pipe Jindal, Sail, Maharashtra Seamless Ltd., Sukeli, Maharashtra or as Approved make M/s. Tata Metaliks Limited, Medinapur ,M/s. Electrosteel Castings Ltd., Kolakatta,M/s. Electrotherm (I) Ltd., Kutch or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Drilling of 900 mm dia Horizontal borehole for watermain pipeline under the railway tracks including all strata with required length including fixing of 800mm dia M.S.casing pipe of minimum 12mm thick Or IRS Casing Pipe with welding pushing etc. complete Providing & fixing various size of pipe for 406.4 mm/457mm/508mm dia watermain of G.I/M.S pipe of minimum 6.3 mm thick for railway premises as per instruction & regulations of Railway authority & under supervision of Railway authority including Providing & supplying fixing of spacer at specified interval if required between Casing pipe and water main, ISI make sluice valve of required size at both side of railway boundary with construction of brick edge pavement including C:C encasing 1:3:6 in 10 mtr length of pipe at both side. Including Providing & fixing of M.S/Iron Manhole frame with cover for valve chamber with locking arrangement etc. complete with all material labour fabrication,hydralic testing of pipe & valve etc. complete for 45 mt Length. Which includes horizontal pushing and with open excavation.MS Casing Pipe + Water Main Size-457 mm (For 450 mm Dia. Pipe Crossings) Approved make of MS pipe Jindal, Sail, Maharashtra Seamless Ltd., Sukeli, Maharashtra or as approved by Chief Technical Officer (CTO).

3

-

-

... More
House Service Connections -House Connection from Proposed Pipe Lines including supply fitting and fixing of ferrule connection of Gun Metal, Elbows, Adaptors, GI Pipes of class B of Length 10 m Or as per requirements of local conditions etc. as deemed necessary for the completion of work as per specification as per drawing as directed by Engineer in charge etc. complete.-15 mm dia Approved make of pipe M/s. Asian Mills Pvt. Ltd., Ahmedabad, M/s. Riddhi Steel & Tubes (P) Ltd., Ahmedabad or as approved by Chief Technical Officer (CTO).

2000

-

-

... More
House Service Connections -House Connection from Proposed Pipe Lines including supply fitting and fixing of ferrule connection of Gun Metal, Elbows, Adaptors, GI Pipes of class B of Length 10m Or as per requirements of local conditions etc. as deemed necessary for the completion of work as per specification as per drawing as directed by Engineer in charge etc. complete.-20 mm dia Approved make of pipe M/s. Asian Mills Pvt. Ltd., Ahmedabad, M/s. Riddhi Steel & Tubes (P) Ltd., Ahmedabad or as approved by Chief Technical Officer (CTO).

875

-

-

... More
House Service Connections -House Connection from Proposed Pipe Lines including supply fitting and fixing of ferrule connection of Gun Metal, Elbows, Adaptors, GI Pipes of class B of Length 10m Or as per requirements of local conditions etc. as deemed necessary for the completion of work as per specification as per drawing as directed by Engineer in charge etc. complete.-25 mm dia Approved make of pipe M/s. Asian Mills Pvt. Ltd., Ahmedabad, M/s. Riddhi Steel & Tubes (P) Ltd., Ahmedabad or as approved by Chief Technical Officer (CTO).

875

-

-

... More
House Service Connections -House Connection from Proposed Pipe Lines including supply fitting and fixing of ferrule connection of Gun Metal, Elbows, Adaptors, GI Pipes of class B of Length 10m Or as per requirements of local conditions etc. as deemed necessary for the completion of work as per specification ,as per drawing as directed by Engineer in charge etc. complete.-50 mm dia Approved make of pipe M/s. Asian Mills Pvt. Ltd., Ahmedabad, M/s. Riddhi Steel & Tubes (P) Ltd., Ahmedabad or as approved by Chief Technical Officer (CTO).

100

-

-

... More
House Service Connections -House Connection from Proposed Pipe Lines including supply fitting and fixing of ferrule connection of Gun Metal, Elbows, Adaptors, GI Pipes of class B of Length 10m Or as per requirements of local conditions etc. as deemed necessary for the completion of work as per specification as per drawing as directed by Engineer in charge etc. complete.-75 mm dia Approved make of pipe M/s. Asian Mills Pvt. Ltd., Ahmedabad, M/s. Riddhi Steel & Tubes (P) Ltd., Ahmedabad or as approved by Chief Technical Officer (CTO).

75

-

-

... More
House Service Connections -House Connection from Proposed Pipe Lines including supply fitting and fixing of ferrule connection of Gun Metal, Elbows, Adaptors, GI Pipes of class B of Length 10m Or as per requirements of local conditions etc. as deemed necessary for the completion of work as per specification as per drawing as directed by Engineer in charge etc. complete.-90 mm dia Approved make of pipe M/s. Asian Mills Pvt. Ltd., Ahmedabad, M/s. Riddhi Steel & Tubes (P) Ltd., Ahmedabad or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-In all sorts of soil and soft murrum - (1) Up to 1.5 Mt. Depth

26

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-In all sorts of soil and soft murrum - (2) 1.5 to 3.0 Mt. Depth (In Hard Murum)

21

-

-

... More
Providing and laying cement concrete 1:3:6 (1 cement: 3 sands: 6 graded stone aggregates 20 nominal size) and curing complete including cost of formwork for foundation and plinth

4

-

-

... More
Providing & laying controlled cement concrete M250 and curing complete including the cost of formwork but excluding the cost of reinforcement for reinforced concrete work in foundations, footings, base of columns and mass concrete.

4

-

-

... More
Providing & laying controlled cement concrete M250 and curing complete including the cost of formwork but excluding the cost of reinforcement for reinforced concrete work up to floor two level. (A) COLUMNS

6

-

-

... More
Providing & laying controlled cement concrete M250 and curing complete including the cost of formwork but excluding the cost of reinforcement for reinforced concrete work up to floor two level. (B) BEAMS

4

-

-

... More
Providing & laying controlled cement concrete M250 and curing complete including the cost of formwork but excluding the cost of reinforcement for reinforced concrete work up to floor two level. (C) chhajja

1

-

-

... More
Providing & laying controlled cement concrete M250 and curing complete including the cost of formwork but excluding the cost of reinforcement for reinforced concrete work up to floor two level. (D) SLAB

2

-

-

... More
Providing and laying cement concrete flooring 1:2:4 (1 - cement, : 2 - coarse sand : 4 - 20 mm nominal size graded some aggregate) laid in one layer and finished with a floating coat of neat cement - 50 mm thick at 26 lac ESR (Diameter of floring is 30.40 m)

726

-

-

... More
Transportation charges for shifting and stacking of existing materials i.e. HDPE pipes, MS pipes, Pumps, Valves etc. at 26 lac liter ESR with all lead as including all labor, vehicle, loading & unloading etc. complete and as per instruction of Engineer in charge

1

-

-

... More
Steel /Reinforcement- Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for all diameters CRS steel all diameter Fe 500grade confirming to relevant I.S. (The Makes of the Steel shall be like SISCOL / SAIL / TISCON / RINL/ TATA /JINDAL or as approved by Chief Technical Officer (CTO)

2238

-

-

... More
Providing and constructing brick work using common burnt clay build bricks having crushing strength not less than 35 KG/SQ CM -up to floor two level in cement mortar 1:6 (1 cement: 6 fine sand) (B) Conventional

7

-

-

... More
Filling in trenches with available excavated earth (excluding rock in trenches plinth, sides of foundations etc. in layer not exceeding 20 cm in depth consolidating each disposable layer by ramming and watering.)

21

-

-

... More
Providing and filling in plinth with murrum or selected soil in layers of 20 cm in thickness including watering, ramming and consolidation etc. complete In Plinth

187

-

-

... More
Providing and applying 10 mm thick cement plaster in single coat on brick / concrete walls and similar surfaces for plastering and finishing even and smooth inside cupboard in CM 1:3 (1 cement: 3 sand)

34

-

-

... More
Providing and applying 20 mm thick sand faced double coat cement plaster on walls or similar surfaces consisting of 12 cm thick backing cost of CM 1:3 (1 cement: 3 sand) and 8 cm thick finishing cost of CM 1:1 (1 cement :1 sand) etc. complete.

40

-

-

... More
Proving 35 mm wide throating or plaster drip and moulding it to R.C.C. Chajja etc. complete as directed by Engineer in charge.

7.2

-

-

... More
Providing 20 mm deep finished groove in plaster in line and level etc. complete as directed by Engineer in charge.

7.2

-

-

... More
Providing and laying green polished kota stone slab flooring over 20 mm (average) thick base of cement mortar 1:6 (1cement: 6 sand) laid over and joined with grey cement slurry including and polishing etc. complete. (A) 25 mm thick

9

-

-

... More
Providing and fixing 35 mm finished thick Indian teakwood shutters, for doors, windows and clear storey windows including the salwood frames of finished size 12 cm x 7 cm including medium quality anodised aluminum fixtures and fastenings including primer coat of approved quality and two coats of oil painting etc. complete. Fully Panelled.

2.3

-

-

... More
Providing and fixing window having extruded aluminum colour powder coated section frame main outer size 95 mm x 24 mm x 1.17 mm (of Jindal section no: 2459 @ wt. of 0.738 kg/mt.), horizontal three track member size 92 mm x 31.75 mm x 1.30 mm (of Jindal section no: 8688 @ wt. of 1.07 kg/mt.), vertical member of size 92 mm x 31.75 mm x 1.50 mm (of Jindal section no: 8933 @ wt. of 1.06 kg/mt.), with sliding shutter of horizontal member size 40 mm x 18 mm x 1.29 mm (of Jindal section no: 8947 @ wt. of 0.456 kg/mt.), vertical member of size 40 mm x 18 mm x 1.29 mm (of Jindal section no: 8949 @ wt. of 0.738 kg/mt.), with 5 mm thick transparent bronze colour tinted float glass with powder coated aluminum fitting and fixtures and transparent silicon sealant glass fixing to frame as per details including removing existing frames and fixing new frame etc complete as directed by Engineer in charge..

3.6

-

-

... More
Distempering two coats with oil bound washable distemper of approved brand & manufacture & of required shade on wall surface to give an even shade over and & including a priming coat of alkali resistance primer of approved brand after thoroughly brushing the surface to give an even shade after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and smooth.

34

-

-

... More
Providing and applying finishing wall or similar surfaces with water proofing cement paint (three coats) at all floor level of approved brand and manufacture and in required shape, even shade after thoroughly brushing and watering the surface to remove all dirts and remains of loose powdered material (A) For wall.

40

-

-

... More
Providing and fixing M.S. Grills of required pattern to wooden frames of windows etc. at all floor levels with MS flats at required spacing and frame around square or round bars with round headed bolts and nuts or by screw including Priming coat of Red lead paint, 2 coats of approved enamel paint as directed by Engineer in charge etc. with all material & labour, complete etc. complete (A) plain grill for all floors. In windows.

90

-

-

... More
Providing & fixing steel work welded in built up structural M.S. Sections, Plates etc. for Platform, MS ladder, inserts including fabrication as shown in the drg. all steel work to have primer coat of red oxide zinc chromate paint to relevant IS followed by final coat as per specification / 2 coats of approved enamel paint as directed by engineer in charge etc. with all material & labour, complete. Entry Gate

3632

-

-

... More
Providing and fixing RCC benches for seating in garden area in M 200 grade of concrete including reinforcement, shuttering, curing & finishing with 15 mm thick plaster in C.M. 1:1 etc. complete as per detailed working & structural drawing and instruction of Engineer in charge.

50

-

-

... More
Providing, fixing and Lettering Stainless steel Font " SILVASSA MUNICIPAL COUNCIL WATER TREATMENT PLANT (height 12") on FRONT TOP beam as per drawing. at elevation portion as directed by Engineer in charge.

45

-

-

... More
Providing & fixing steel work welded in built up structural M.S. Sections, Plates etc. for Platform, MS ladder, inserts including fabrication as shown in the drg. all steel work to have primer coat of red oxide zinc chromate paint to relevant IS followed by final coat as per specification / 2 coats of approved enamel paint as directed by engineer in charge etc. with all material & labour, complete. Compound railing

37044

-

-

... More
Providing and fixing Light Point (One Light Point controlled with one single way 6 A Switch), Light Point (One Light Point controlled with two single way 6 A Switch- Two way Light Point),Fan Point (One Fan Point controlled with one single way 6 A Switch) & Bell point

20

-

-

... More
Providing and fixing One 5 pin 5A 250 Volt Socket out let point controlled by 6 A switch on board, as directed by Engineer-In-Charge, etc. complete.

6

-

-

... More
Providing Electronic hum free five steps EME fan regulator of modular type accessories mounted with PVC/Metallic box covered with appropriate front plate modules erected with necessary connection. Cat - II

1

-

-

... More
Providing Electronic hum free five steps EME fan regulator of modular type accessories mounted with PVC/Metallic box covered with appropriate front plate modules erected with necessary connection. Cat - II

3

-

-

... More
Providing Two pin /RJ -11 Telephone socket with top (Cat III) modular type accessories mounted with PVC / metallic box, single mounting base frame covered with textured/metallic front plate, modules erected with necessary connection as desired by engineer in charge.

1

-

-

... More
Providing & laying Rigid PVC pipe confirming to I.S.S., erected with necessary fittings fixed with adhesive solution with 16 G. GI fish wire for concealed in wall / slab / Flooring with necessary cementation. Cabin & ESR - 20 mm Size (3/4")

115

-

-

... More
Providing & laying Rigid PVC pipe confirming to I.S.S., erected with necessary fittings fixed with adhesive solution with 16 G. GI fish wire for concealed in wall / slab / Flooring with necessary cementation. Cabin & ESR - 25 mm Size (1")

40

-

-

... More
Supply and laying of main lines with ISI marked Copper conductor FRLS / ZHFR PVC insulated copper wire in existing pipe erected with earth continuity wire as specified in specification for following size. - 2 wire 2.5 mm2 with 1.5 mm2 Cu earth wire

40

-

-

... More
Supplying and erecting approved make Telephone Cable electrolytic grade annealed copper conductor insulated with PE insulation twisted in to pairs with colour combination bunched together in concentric layers so as to minimal cross-talk & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for indoor telephone wiring & conforming to C-DOT S/WS113/IEC 60189-2, UL1581 section 1080 VW-1 erected with necessary connections. 2 Pair Telephone Cable

15

-

-

... More
Approved make Ceiling fan with condenser A.C. 50 Cys. 1400 mm. sweep complete, canopy and 30 cm. Down rod erected on existing hook or clamp with 24/0.2 flat 3 core flexible wire with earthing (or R.C. Rate) in Two Rooms 1.0 No. each

1

-

-

... More
Supplying & erecting approved make 1 x 40 watt white stove enameled patti type fluorescent fitting made of M.S. Sheet 0.8 mm thick white or reflector side. Complete with 40 watts polyester heavy duty copper wound ballast, lock type tube holders, starter, duly wired for use on 250 volt A.C. supply and erected if required on varnish P.W. block with lead wires & connection in Two Rooms 3.0 Nos. each etc complete..

15

-

-

... More
Bypass Arrangement for the 11 LL capacity ESR HSC Pumps at Proposed Pump House at 15 MLD-Providing, supplying, erecting, testing and commissioning of horizontal split casing centrifugal pump set with suitable TEFC squirrel cage induction motor working on three phase 50 Hz ±3%, 415V ± 10%, along ith base frame, coupling with guard, foundation bolts etc. complete set as per relevant IS and following MOC. Impellar with wearing ring- Bronze, Shaft with sleeve - S.S, Casing - C.I, Base frame - M.S.415 m3/hr at 44m head (75 kW) Make – Kirloskar brothers ltd, Wilo, MBH pumps, Jyoti ltd or as approved by Chief Technical Officer (CTO).

2

-

-

... More
HSC Pumps for 12 LL ESR at Proposed Pump House at 15 MLD -Providing, supplying, erecting, testing and commissioning of horizontal split casing centrifugal pump set with suitable TEFC squirrel cage induction motor working on three phase 50 Hz ±3%, 415V ± 10%, along with base frame, coupling with guard, foundation bolts etc. complete set as per relevant IS and following MOC. Impellar with wearing ring- Bronze, Shaft with sleeve - S.S, Casing - C.I, Base frame - M.S.415 m3/hr at 44m head (75 kW) Make – Kirloskar brothers ltd , Wilo, MBH pumps, Jyoti ltd or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Vacuum pump-Providing, erecting approved make monoblock watering vacuum pump set having air flow rate 49m3/hr with maximum vacuum 710 mmHG and 3HP horizontal foot mounted TEFC squirrel cage motor having under mentioned capacity working on three phase 50 Hz, 415V±10%, with base plate, DOL starter, cable, GI medium duty suction pipes 10m long, specials, valves, PVC tank of 200 liters capacity etc. complete set. MOC: Rotor-Bronze, invloute-CI, Shaft-CS Make - Kirloskar brothers ltd, IVC pumps Pvt Ltd, Greaves or as approved by Chief Technical Officer (CTO).

1

-

-

... More
HSC Pumps-Providing, supplying, erecting, testing and commissioning of horizontal split casing centrifugal pump set with suitable TEFC squirrel cage induction motor working on three phase 50 Hz ±3%, 415V ± 10%, along with base frame, coupling with guard, foundation bolts etc. complete set as per relevant IS and following MOC. Impeller with wearing ring- Bronze, Shaft with sleeve - S.S, Casing - C.I, Base frame - M.S.555 m3/hr. at 44m head (90 kW) Make – Kirloskar brothers ltd , Wilo, MBH pumps,, Jyoti ltd or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Pipes-Centrifugally cast (Spun) Ductile Iron pressure pipes with flanged (welded) ends for water, gas, sewage conforming to IS: 8329/2000 for classification K-9 with cement mortar lining inside the pipes with outside zinc coating. including Transportation, Taxes and dutie-300mm Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

8

-

-

... More
Sluice Valve Supply, Delivery of D.I double flanged Sluice Valves conforming to IS- 14846 (with up to date amendments, if any) including gear arrangements for the following dia. as per test pressure having Body, Bonnet, Dome, Stool cover, Wedge, Stuffing box, Gland, Thrust plate, Cap/Hand wheel with D.I; Stem, Body seat ring, Wedge facing ring, Bushes, Bolts, Nuts, Pinion and Pinion shaft with Stainless steel (IS 6603) ; Wedge nut, Shoe, Channel with Leaded Tin Bronze ( IS 318 ); Gasket with Neoprene Rubber; Gland packing with Rubber; Gear, Gear housing with Cast Steel including all taxes and transportation, etc. complete ISI marked-.300mm PN 1.0 Make - Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Existing Clear water pump house at PWD quarters- -DI Pipes-Providing and supplying DI K-9 grade pipes for the following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.-100mm dia Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

10

-

-

... More
DI Pipes-Centrifugally cast (Spun) Ductile Iron pressure pipes with flanged (welded) ends for water, gas, sewage conforming to IS: 8329/2000 for classification K-9 with cement mortar lining inside the pipes with outside zinc coating including all taxes,duties and transportation,.- 350mm Dia Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

28

-

-

... More
Sluice Valve-Supply, Delivery of D.I double flanged Sluice Valves conforming to IS- 14846 (with up to date amendments, if any) including gear arrangements for the following dia. as per test pressure having Body, Bonnet, Dome, Stool cover, Wedge, Stuffing box, Gland, Thrust plate, Cap/Hand wheel with D.I; Stem, Body seat ring, Wedge facing ring, Bushes, Bolts, Nuts, Pinion and Pinion shaft with Stainless steel (IS 6603) ; Wedge nut, Shoe, Channel with Leaded Tin Bronze ( IS 318 ); Gasket with Neoprene Rubber; Gland packing with Rubber; Gear, Gear housing with Cast Steel, including all taxes and transportation, etc. complete ISI marked.-350mm PN 1.0 Make -Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

4

-

-

... More
Reflux valve-Providing and supplying ISI mark CI D/F Reflux valves of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete PN1 IS 5312 with ISI mark-100mm dia Make - Kirloskar Brothers Ltd, IVC, VAG valves or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Pipes-Centrifugally cast (Spun) Ductile Iron pressure pipes with flanged (welded) ends for water, gas, sewage conforming to IS: 8329/2000 for classification K-9 with cement mortar lining inside the pipes with outside zinc coating including all taxes and duties, transporataion. -400 mm Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

3

-

-

... More
Sluice Valve-Supply, Delivery of D.I double flanged Sluice Valves conforming to IS- 14846 (with up to date amendments, if any) including gear arrangements for the following dia. as per test pressure having Body, Bonnet, Dome, Stool cover, Wedge, Stuffing box, Gland, Thrust plate, Cap/Hand wheel with D.I; Stem, Body seat ring, Wedge facing ring, Bushes, Bolts, Nuts, Pinion and Pinion shaft with Stainless steel (IS 6603) ; Wedge nut, Shoe, Channel with Leaded Tin Bronze ( IS 318 ); Gasket with Neoprene Rubber; Gland packing with Rubber; Gear, Gear housing with Cast Steel including all taxes and transportation, etc. complete ISI marked.-400 mm PN 1.0 Make - Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Pipeline from proposed CWPH at 15 MLD to Bypass Arrangement for the 11 LL capacity ESR and pumping main for 12 LL ESR - Centrifugally cast (Spun) Ductile Iron pressure pipes with flanged (welded) ends for water, gas, sewage conforming to IS: 8329/2000 for classification K-9 with cement mortar lining inside the pipes with outside zinc coating., including transportation, taxes & duties.-450mm Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

200

-

-

... More
Non return valves-Manufacture, Supply and delivery of DI D/F Tilting disc Swing Check Valves Slanted seated with maximum swing of 59 degree with metallic, corrosion proof and wear resistant seat faces, Body and Disc of ductile cast iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 Shafts of stainless steel, shaft bearing of zinc free bronze and Integral body seat face & disc face with nickel-chromium overlay welding and micro finished. All the inside and outside of the body is to be coated with double coating of food grade epoxy liquid lacquer (EP-F) with minimum thickness of 150 microns, color: RAL 5005 Blue face to face dimensions according to EN 558-1/14/DIN 3202-F4, Flange dimensions according to EN1092-2/IS 1538- 300 mm Make - VAG valves, Taalis, Hawa valves, R&D Multiples or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Pipes-Centrifugally cast (Spun) Ductile Iron pressure pipes with flanged (welded) ends for water, gas, sewage conforming to IS: 8329/2000 for classification K-9 with cement mortar lining inside the pipes with outside zinc coating.,including transportation, taxes & duties.-500mm Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

4

-

-

... More
Non return valves-Manufacture, Supply and delivery of DI D/F Tilting disc Swing Check Valves Slanted seated with maximum swing of 59 degree with metallic, corrosion proof and wear resistant seat faces, Body and Disc of ductile cast iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 Shafts of stainless steel, shaft bearing of zinc free bronze and Integral body seat face & disc face with nickel-chromium overlay welding and micro finished. All the inside and outside of the body is to be coated with double coating of food grade epoxy liquid lacquer (EP-F) with minimum thickness of 150 microns, color: RAL 5005 Blue face to face dimensions according to EN 558-1/14/DIN 3202-F4, Flange dimensions according to EN1092-2/IS 1538-350mm Make – VAG valves, Taalis, R&D Multiples, Hawa valves or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-90° Bend Double Flange bend - 450mm (Wt - 146kg) Make - Electrosteel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

6

-

-

... More
Dismantling joints-Manufacture, Supply and Delivery of C.I Dismantling Joints with both side flange end suitable for installation in between flange end pipes. including Excise duty, Taxes and transportation charges etc., complete-300mm PN 1.0 Make - Durga valves, Anant Engineers & Fabricators, Makali Engineering Corporation, Viking Johnson or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-Double Flange Reducer - 350mm x 200mm (Wt - 58kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Dismantling joints-Manufacture, Supply and Delivery of C.I Dismantling Joints with both side flange end suitable for installation in between flange end pipes.including Excise duty, Taxes and transportation charges etc., complete-350mm PN 1.0 Make - Durga valves, Anant Engineers & Fabricators, Makali Engineering Corporation, Viking Johnson or as approved by Chief Technical Officer (CTO).

4

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-Double Flange Reducer - 400mm x 300mm (Wt - 71kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Dismantling joints-Manufacture, Supply and Delivery of C.I Dismantling Joints with both side flange end suitable for installation in between flange end pipes. including Excise duty, Taxes and transportation charges etc complete-400mm PN 1.0 Make - Durga valves, Anant Engineers & Fabricators, Makali Engineering Corporation, Viking Johnson or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Existing Clear water pump house at PWD quarters-Supplying, erection, testing & commissioning of horizontal monoblock submersible pump set with motor confirming to IS-9283-1979 working at 3 phase 400/440 volt 50 c/s A.C supply & 2900 rpm-.525 LPM @ 25m head. Make – Kirloskar brothers ltd, Wilo, Beacon weir Ltd, Lubi pumps or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-Double Flange Enlarger - 150mm x 300mm (Wt - 36kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

4

-

-

... More
Sluice valve-Supply, installing, testing and commissioning of double flanged Sluice Valves conforming to IS- 14846 (with up to date amendments, if any) including electric actuator including gear arrangements for the following dia. as per test pressure having Body, Door, Dome, Stuffing Box, Gland, Hand Wheel, Wedge, Seat, Face Ring of Bronze (IS 318, LTB-2), Spindle of Stainless Steel (ASTM A276, Type-316), Bonnet Gasket of EPDM, Internal Fasteners of Stainless Steel (ASTM A276, Type-316), Nuts, Bolts & Washers of High Tensile Steel Hot Dip Galvanized, Gear Box Cover and Casing of Cast Iron (IS: 210, Gr. FG 260); Gear housing with Cast iron etc. complete ISI marked. -100mm dia Make - Kirloskar Brothers Ltd, IVC, AVK or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) (ex-works) including Transportation, Taxes and Duties etc.-Double Flange Enlarger -200mm x 350mm (Wt - 48kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-Double Flange Enlarger - 300mm x 450mm (Wt - 69kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-Double Flange Enlarger -350mm x 450mm (Wt - 70kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Supplying, installing, testing and commissioning of central drive, vertical downward, top mounted, slow speed, alum tank agitator with gear box and motor suitable for 415V, 1440 RPM, 50 Hz, IP55, IE2, suitable for tank 1m x 1m x 2m having Shaft and impeller of SS 304. Make – REMI, Milton Roy India, Fiber & Fiber, Envifab equipments, Ceecons India, Shree Virkrupa Engineering or as approved by Chief Technical Officer (CTO).

3

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. including lowering and laying , zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-All Flanged unequal tee - 500mm x 500mm x 350mm (Wt - 240kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

4

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. including lowering and laying, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-All Flanged equal tee - 500mm x 500mm x 400mm (Wt - 250kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-All Flanged equal tee - 450mm x 450mm x 450mm (Wt - 201kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-Blank flange - 500mm (Wt - 65kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-Puddle pipe - 350mm (Wt - 127kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, Tata Metaliks or as approved by Chief Technical Officer (CTO).

4

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-Puddle pipe - 400mm (Wt - 153kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Sluice valve with actuators-Supply, installing, testing and commissioning of double flanged Sluice Valves conforming to IS- 14846 (with up to date amendments, if any) including electric actuator including gear arrangements for the following dia. as per test pressure having Body, Door, Dome, Stuffing Box, Gland, Hand Wheel, Wedge, Seat, Face Ring of Bronze (IS 318, LTB-2), Spindle of Stainless Steel (ASTM A276, Type-316), Bonnet Gasket of EPDM, Internal Fasteners of Stainless Steel (ASTM A276, Type-316), Nuts, Bolts & Washers of High Tensile Steel Hot Dip Galvanized, Gear Box Cover and Casing of Cast Iron (IS: 210, Gr. FG 260); Gear housing with Cast iron etc. complete ISI marked. valve actuators for Gate / Sluice valves shall be totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams, torque switch dial and with TEFC squirrel cage induction motor working on 415 Volts, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be at least 1.5 times max. torque required for opening and closing of valve-Filtration Plant-200 mm Make Sluice valve - Kirloskar Brothers Ltd, IVC, AVK Make Actuator – AUMA, Rotork, Limitork or as approved by Chief Technical Officer (CTO).

8

-

-

... More
DI Fittings-Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. item mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties etc.-Bellmouth - 350mm (Wt - 36kg) Make - Electro Steel Castings, Jindal SAW Ltd, Kejriwal Casting Ltd, SriKalahasti pipes, Tata Metaliks or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Air release valve-Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG- 400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS /PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and inclusive of all taxes and transportation etc., complete.-100mm Make - Approved make M/s. Kirloskar Brothers Ltd., M/s. VAG Valves India Pvt. Ltd. M/s IVI ltd, IVC Ltd, or as approved by Chief Technical Officer (CTO)

2

-

-

... More
Sluice valve with actuators-Supply, installing, testing and commissioning of double flanged Sluice Valves conforming to IS- 14846 (with up to date amendments, if any) including electric actuator including gear arrangements for the following dia. as per test pressure having Body, Door, Dome, Stuffing Box, Gland, Hand Wheel, Wedge, Seat, Face Ring of Bronze (IS 318, LTB-2), Spindle of Stainless Steel (ASTM A276, Type-316), Bonnet Gasket of EPDM, Internal Fasteners of Stainless Steel (ASTM A276, Type-316), Nuts, Bolts & Washers of High Tensile Steel Hot Dip Galvanized, Gear Box Cover and Casing of Cast Iron (IS: 210, Gr. FG 260); Gear housing with Cast iron etc. complete ISI marked. valve actuators for Gate / Sluice valves shall be totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams, torque switch dial and with TEFC squirrel cage induction motor working on 415 Volts, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be at least 1.5 times max. torque required for opening and closing of valve-At pump house 1-200 mm-200 mm Make Sluice valve - Kirloskar Brothers Ltd, IVC, AVK Make Actuator – AUMA, Rotork, Limitork or as approved by Chief Technical Officer (CTO).

1

-

-

... More
EOT crane at (15 MLD WTP) new pumping station and it should be erected on gantry girder.-Providing & erecting single girder type fully electrically operated EOT crane with electrically operated hoist, class II duty, geared travelling trolley with five mtr lift complete, all three motions electrically operated by suitable rating motor IP 54, control panel & down pendant control block, brake, safety device, cables from motor to starter panel & other required accessories & tested to 50% overload-2 Ton capacityMake - Hercules Mechanical works, Electromech Engineers, Cranedge India Pvt Ltd, RMS Industries, Indef or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Chain pulley block (Capacity 2 Tonne)-Providing Chain pulley block with triple gear arrangement, lifting hook, load chain & hand chain & locking device with spur gear travelling trolley & all accessories Make: Indef, Sealinkers Pvt Ltd, Morris, Indef, Safex, W H Brady or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Electric Operated Existing 15 MLD intake-Sluice gate-Supplying, lowering, laying, jointing of Thimble mounted Sluice gates of size 900mm (W) x 900mm (H) including all taxes, freight, inspection charges unloading, loading into truck, transportation up to stores/ site, unloading, stacking, including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. Make – Jash, Makali Engineering Corporation, H Sarkar & Co Ltd, Yaswant Industrial works, HWE or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Sluice valve with actuators-Supply, installing, testing and commissioning of double flanged Sluice Valves conforming to IS- 14846 (with up to date amendments, if any) including electric actuator including gear arrangements for the following dia. as per test pressure having Body, Door, Dome, Stuffing Box, Gland, Hand Wheel, Wedge, Seat, Face Ring of Bronze (IS 318, LTB-2), Spindle of Stainless Steel (ASTM A276, Type-316), Bonnet Gasket of EPDM, Internal Fasteners of Stainless Steel (ASTM A276, Type-316), Nuts, Bolts & Washers of High Tensile Steel Hot Dip Galvanized, Gear Box Cover and Casing of Cast Iron (IS: 210, Gr. FG 260); Gear housing with Cast iron etc. complete ISI marked. Valve actuators for Gate / Sluice valves shall be totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams, torque switch dial and with TEFC squirrel cage induction motor working on 415 Volts, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be at least 1.5 times max. torque required for opening and closing of valve.-Filter Bed-300mm Make Sluice valve - Kirloskar Brothers Ltd, IVC, AVK Make Actuator – AUMA, Rotork, Limitork or as approved by Chief Technical Officer (CTO).

6

-

-

... More
Sluice valve with actuators-Supply, installing, testing and commissioning of double flanged Sluice Valves conforming to IS- 14846 (with up to date amendments, if any) including electric actuator including gear arrangements for the following dia. as per test pressure having Body, Door, Dome, Stuffing Box, Gland, Hand Wheel, Wedge, Seat, Face Ring of Bronze (IS 318, LTB-2), Spindle of Stainless Steel (ASTM A276, Type-316), Bonnet Gasket of EPDM, Internal Fasteners of Stainless Steel (ASTM A276, Type-316), Nuts, Bolts & Washers of High Tensile Steel Hot Dip Galvanized, Gear Box Cover and Casing of Cast Iron (IS: 210, Gr. FG 260); Gear housing with Cast iron etc. complete ISI marked. Valve actuators for Gate / Sluice valves shall be totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams, torque switch dial and with TEFC squirrel cage induction motor working on 415 Volts, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be at least 1.5 times max. torque required for opening and closing of valve-At recirculation sump-150mm Make Sluice valve -Kirloskar Brothers Ltd, IVC, AVK Make Actuator – AUMA, Rotork, Limitork or as approved by Chief Technical Officer (CTO).

4

-

-

... More
Actuator-Supply, erection of electric Valve actuators for Gate / Sluice valves totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams, torque switch dial and with TEFC squirrel cage induction motor working on 415 Volts, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be at least 1.5 times max. torque required for opening and closing of valve. Filter bed-600mm Make Actuator – AUMA, Rotork, Limitork or as approved by Chief Technical Officer (CTO).

6

-

-

... More
ELECTRICL: HT Cable- Supply, Installation, Testing and Commissioning of XLPE insulated, Aluminum conductor E grade, Single core, stranded, Aluminum conductor, screened by extruded semi-conducting compound for the conductor, cross-linked poly ethylene (XLPE) insulated, screened by extruded semi-conducting compound for the insulation followed with copper tape and inner and outer extruded PVC sheath compound Type-ST2 and galvanised steel round wire armouring of following sizes to be buried in ground/ laid in ducts / laid in trays in ready made trenches, Civil work such as excavation, backfilling, sand, brick/tile/semi-circle hume pipe protection (if require) etc. Removal of empty drums, cartoons & making the site normal as instructed by Client is included in the scope. Work should be done as per DNHPDCL / Supply authority requirements/ guidelines and norms. The makes of cable shall be Polycab, RPG, RR Cable, Universal, Finolex or as approved by Chief Technical Officer (CTO). 11KV(E), 3C X 240 sq.mm A2XWY CABLE (Clear Water Pumping Station-from DNHPDCL DP/ existing CSS near WTP)

100

-

-

... More
Supply, Installation, Testing and Commissioning of heat shrinkable indoor type termination kits suitable for following sizes of , XLPE insulated Aluminum conductor, E grade, round wire armoured cable. The makes of cable jointing kit shall be 3M, Raychem, Denson or as approved by Chief Technical Officer (CTO). 11KV(E), 3C X 240 sq.mm A2XWY CABLE

2

-

-

... More
Supply, Installation, Testing and Commissioning of heat shrinkable outdoor type termination kits suitable for following sizes of , XLPE insulated Aluminum conductor, E grade, round wire armoured cable. The makes of cable jointing kit shall be 3M, Raychem, Denson or as approved by Chief Technical Officer (CTO). 11KV(E), 3C X 240 sq.mm A2XWY CABLE

2

-

-

... More
Wire fencing (For RMU & Transformer Yard): For Clear Water Pumping Station Providing and fixing 2.0 mtr. high Wire Fencing with 2.8 Mtr. long M.S. angle posts 40mm X 40mm X 6mm and oil painting 3 coats fixed at 2.5 Mtr. C/C with eight Horizontal line & two diagonals of galvanized steel barbed wire weighting 9.38 Kg./ 100 Mtr. strained including fixing the posts in ground with 0.5 Mtr. X 0.5 Mtr. X 0.5 Mtr. block in cement concrete 1:5:10 etc. including laying of best quality gravel bed of suitable size inside wire fencing in switchyard .

2

-

-

... More
M.S. Gate (For RMU & Transformer Yard): For Clear Water Pumping Station Providing and fixing M.S. gate made from M.S. angles, channels and flats including all labour and material cost with painting and fixing at site of work including carting, loading, unloading etc. complete with M.S. Gate 1 Mtr. x 2 Mtr. in structural steel.

90

-

-

... More
LT PMCC Panel for 15 MLD Clear Water Pumping Station: Design, manufacturing, Supply, Loading, Packing, forwarding, Unloading, handling (shifting from place of unloading to place of storage and shifting from the place of storage to the place of installation including insurance), storage at site, assembly, installation, conducting pre-commissioning test as per IS & IEC Standards, commissioning & performance demonstration of following weather proof, dust & vermin proof, floor mounted front operated indoor type cubical switchgear enclosure having IP-64 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire / copper-aluminum strips, rubber grommets, rib, bakelite control fuses for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. Cupboard with dimension 4m (L) x 2.3m (H) x 0.750 (D) Incoming- 1. 630A FP Microprocessor based MCCB with O/L, S/C and E/F Protection- 2 Nos 2. Digital Multi-function meter with RS 485 communication port of accuracy class-1- 2 Nos Indicating Real Time, Total active energy (KWH/MWH), Maximum demand (KVA/MVA) (KW/MW), Instantaneous power factor, Voltage , Current, abd Frequency 3. 2 set of Breaker ON / OFF / TRIP indicating lights with control MCB’s. 4. 2 set of 0-500 Volt digital voltmeter with selector switch protected by 2 amp TP MCB’s 5. 2 set of 0-630 Amps digital electronic ammeter with selector switch with 1 no. 630/5A, 5VA, CL-1.0 Current Transformer 6. 2 set of R,Y,B Phase indicating lamps with control MCB’s. Outgoing- 1. 250 A, FP MCCB with S/C and E/F Protection with Soft Starter for 90kW Motor- 2 Nos 2. 160A, FP MCCB with S/C and E/F Protection with Soft Starter for 75kW Motor- 2 No 3. 250 A, FP MCCB with S/C and E/F Protection- 1 No 4. 32 A, FP MCB - 2 Nos 5. 16 A, FP MPCB with S/C and O/L Protection with DOL Starter for 2HP Motor- 2 Nos 6. 16A, FP MCB -2 Nos Each outgoing motor feeder shall be provided with a CT, Multi-Function Meter, ON/OFF,Trip indication lamps. Refer Drawing No. TCE.11364A-EL-4000-AU-40020 for more details. The makes of Switchgear shall be Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO). Note- The standard companies switch gear shall be used and only manufacturers at CPRI approved factory and shall be certified by that company whose switch gears are used after fabrication for beneficial use.

1

-

-

... More
Soft Starter Panel for 15 MLD Clear Water Pumping Station- Supplying, erecting & commissioning of 415 V Fully automatic Microprocessor based soft starter with built in bypass arrangement for pump control application as per general specification as under: Control Method -Torque Control, Input voltage- 415V, 3 Phase, Input frequency -50/ 60 Hz (±5%), Confirmative to standard - IEC 61947-4- 2UL,CSA,CE, Motor protection - inbuilt Thermal Protection, Starter protection - SC UV, Phase unbalance, Phase failure, EMC Std- IEC 61000-4-2 Level-3 & IEC 61000-4-3-Level-3, Built in communication as per RS 485 e) 75 kW The makes of Switchgear shall be Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Soft Starter Panel for 15 MLD Clear Water Pumping Station- Supplying, erecting & commissioning of 415 V Fully automatic Microprocessor based soft starter with built in bypass arrangement for pump control application as per general specification as under: Control Method -Torque Control, Input voltage- 415V, 3 Phase, Input frequency -50/ 60 Hz (±5%), Confirmative to standard - IEC 61947-4- 2UL,CSA,CE, Motor protection - inbuilt Thermal Protection, Starter protection - SC UV, Phase unbalance, Phase failure, EMC Std- IEC 61000-4-2 Level-3 & IEC 61000-4-3-Level-3, Built in communication as per RS 485 f) 90 kW The makes of Switchgear shall be Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DOL Starter- Supplying, erecting & commissioning of DOL / Star Delta starter suitable for local & remote pump control application consisting of MPCB, overload relay and contactors as per Type II coordination including digital voltmeter, analogue ammeter with selector switch, run hour meter, required protective relays & control accessories. a) D. O. L. up to 3 HP ( for 15 MLD Clear Water Pumping Station- 2 Nos & for WTP- 3 Nos) The makes of Switchgear shall be Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO).

2

-

-

... More
LT PMCC Panel for PWD Pump House: Design, manufacturing, Supply, Loading, Packing, forwarding, Unloading, handling (shifting from place of unloading to place of storage and shifting from the place of storage to the place of installation including insurance), storage at site, assembly, installation, conducting pre-commissioning test as per IS & IEC Standards, commissioning & performance demonstration of following weather proof, dust & vermin proof, floor mounted front operated indoor type cubical switchgear enclosure having IP-64 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire / copper-aluminum strips, rubber grommets, rib, bakelite control fuses for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. Cupboard with dimension 1m (L) x 2.3m (H) x 0.550 (D) Incoming- 1. 1 No. 63A FP Microprocessor based MCCB I/C with LSIG Protection with Electrical Mechanical Interlock. 2. Digital Multi-function meter with RS 485 communication port of accuracy class-1- 1 Nos Indicating Real Time, Total active energy (KWH/MWH), Maximum demand (KVA/MVA) (KW/MW), Instantaneous power factor, Voltage , Current, abd Frequency 3. 1 set of Breaker ON / OFF / TRIP indicating lights with control MCB’s. 4. 1 set of 0-500 Volt digital voltmeter with selector switch protected by 2 amp TP MCB’s 5. 1 set of 0-630 Amps digital electronic ammeter with selector switch with 1 no. 630/5A, 5VA, CL-1.0 Current Transformer 6. 1 set of R,Y,B Phase indicating lamps with control MCB’s. Outgoing- 1. 32A & FP thermal magnetic based MCCB with S/C and O/L Protection for Star Delta Starter for 10HP motor (2W+1S)- 3 Nos 2. 16A & FP thermal magnetic based MCCB with S/C and O/L Protection for Lighting System.- 1 Nos 3. 32A FP MCB - 2 Nos Each outgoing motor feeder shall be provided with a CT, Multi-Function Meter, ON/OFF,Trip indication lamps. Refer Drawing No. TCE.11364A-EL-4000-AU-40019 for more details. The makes of Switchgear shall be Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO). Note- The standard companies switch gear shall be used and only manufacturers at CPRI approved factory and shall be certified by that company whose switch gears are used after fabrication for beneficial use.

1

-

-

... More
Star Delta Starter- Supplying, erecting & commissioning of DOL / Star Delta starter suitable for local & remote pump control application consisting of MPCB, overload relay and contactors as per Type II coordination including digital voltmeter, analogue ammeter with selector switch, run hour meter, required protective relays & control accessories. d) S.D.. up to 10 HP ( for PWD Pump House) The makes of Switchgear shall be Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Power & Receptacle DB: Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grouting nuts & bolts as required complete with making necessary connection as approved, specified and directed by the deptt. 4 way TPN (4+12) double door Incomer- 40 A TPN MCB Outgoing- 16A TPN MCB- 4 Nos 6 A DP MCB- 8 Nos (For Clear Water Pumping Station- 1 Nos, For Intake Well- 1 Nos, For WTP Area- 2 Nos) The makes of Switchgear shall be Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Power Distribution Board Providing and erecting Power Distribution Board made of sheet steel powder coated, surface mounted fitted with busbar,neutral link, earth busbar and DIN rail, conforming to IS 13032 and BS 5486/1986 comprising one Incomer with MCCB and required outgoings with MCBs as follows; (a) 1 No. incomer with 63A FP MCB for lighting & inductive load having 10kA breaking capacity. Cat-III (b) 2 Nos Outgoing each with 32A FP MCB for Power/welding receptacles & Aux loads (C Curve) having 10kA breaking capacity & conforming to IS/IEC 60898-2:2003. Cat-III (c) 4 Nos Outgoing each with 16A FP MCB for indoor lighting & aux loads having breaking capacity 10 KA & confirming to IS/IEC 60898-2:2003. Cat-III (d) 8 Nos Outgoing each with 6-32A SP MCB for 230V aux loads having breaking capacity 10 KA & confirming to IS/IEC 60898-2:2003. (e) Control Transformer of 1000VA, 415/230V AC for I & C Loads. (For Clear Water Pumping Station- 1 No, The makes of Switchgear shall be Siemens, ABB, Schneider Electric, L&T, Legrand or as approved by Chief Technical Officer (CTO).

1

-

-

... More
APFC Panel for 15MLD Clear Water Pumping Station- Supply, Installation, Testing and Commissioning. of APFC panel consisting capacitor bank for continuous duty to improve P.F. 0.85 to 0.99 with dust proof busbar chamber having 2 mm thick sheet steel & earth terminals with painting, enclosure with capacitor unit having 2 Nos., 10 mm earth terminals & two externals, three phase busbar of Cu. supported on epoxy insulators of adequate rating & strips, minimum 5 steps of APFC relay, meters, indicating lamps as mentioned under. 100 KVAR APFCR panel for each item shall include following : (a) Incomer- 250 A, 50kA for 1sec. TP, TM based MCCB with spreader terminals & rotary handle (b) 0-250 A range analogue ammeter of 96 x 96 mm size with selector switch ((c) Three nos. of 250/5 A ratio, 15VA ,CL-1 Current transformers (d) 100A Rating MCCB for each outgoing feeders. (e) 2 nos x 5 KVAR, 2 nos x 10KVAR, 2 nos x 15 KVAR & 2 nos x 20 KVAR APP type capacitor banks (vacuum impregnated with non-PCB / non toxic oil, internally delta connected with built in internal fuses complete with discharge resistances & terminal cover) of approved make in required steps with well suited detuned reactor is placed in series with each capacitor step of approved make as per requirement. (f) Enclosure Dimension- 2100 (H) x 1150 (W) x 600 (D) The makes of Switchgear shall be Schneider, EPCOS, ABB, L & T or as approved by Chief Technical Officer (CTO).

1

-

-

... More
LT Cable- Supply, testing, tagging, laying and commissioning following sizes of 1100 Volt grade, XLPE / PVC insulated multistrand Al. / Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in provided DWC pipe, RCC pipe hume pipe, on provided cable trays / ladders etc. as. required complete with clamps, hardware for fixing tagging, identification etc. The makes of cable shall be RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO) 3.5C x 300 sq mm A2XFY armoured AL Cable

240

-

-

... More
LT Cable- Supply, testing, tagging, laying and commissioning following sizes of 1100 Volt grade, XLPE / PVC insulated multistrand Al. / Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in provided DWC pipe, RCC pipe hume pipe, on provided cable trays / ladders etc. as. required complete with clamps, hardware for fixing tagging, identification etc. The makes of cable shall be RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 3.5C x 150 sq mm A2XFY armoured AL Cable

50

-

-

... More
LT Cable- Supply, testing, tagging, laying and commissioning following sizes of 1100 Volt grade, XLPE / PVC insulated multistrand Al. / Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in provided DWC pipe, RCC pipe hume pipe, on provided cable trays / ladders etc. as. required complete with clamps, hardware for fixing tagging, identification etc. The makes of cable shall be RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 3.5C x 95 sq mm A2XFY armoured AL Cable

40

-

-

... More
LT Cable- Supply, testing, tagging, laying and commissioning following sizes of 1100 Volt grade, XLPE / PVC insulated multistrand Al. / Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in provided DWC pipe, RCC pipe hume pipe, on provided cable trays / ladders etc. as. required complete with clamps, hardware for fixing tagging, identification etc. The makes of cable shall be RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 3.5C x 25 sq mm A2XFY armoured AL Cable

50

-

-

... More
LT Cable- Supply, testing, tagging, laying and commissioning following sizes of 1100 Volt grade, XLPE / PVC insulated multistrand Al. / Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in provided DWC pipe, RCC pipe hume pipe, on provided cable trays / ladders etc. as. required complete with clamps, hardware for fixing tagging, identification etc. The makes of cable shall be RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 4C x 16 sq mm A2XFY armoured AL Cable

450

-

-

... More
LT Cable- Supply, testing, tagging, laying and commissioning following sizes of 1100 Volt grade, XLPE / PVC insulated multistrand Al. / Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in provided DWC pipe, RCC pipe hume pipe, on provided cable trays / ladders etc. as. required complete with clamps, hardware for fixing tagging, identification etc. The makes of cable shall be RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 4C x 10 sq mm A2XFY armoured AL Cable

240

-

-

... More
LT Cable- Supply, testing, tagging, laying and commissioning following sizes of 1100 Volt grade, XLPE / PVC insulated multistrand Al. / Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in provided DWC pipe, RCC pipe hume pipe, on provided cable trays / ladders etc. as. required complete with clamps, hardware for fixing tagging, identification etc. The makes of cable shall be RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 4C x 2.5 Sq.mm. 2XFY CU Cable

550

-

-

... More
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. The makes of cable gland shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 3.5C x 300 sq mm A2XFY armoured AL Cable

4

-

-

... More
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. The makes of cable gland shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 3.5C x 150 sq mm A2XFY armoured AL Cable

4

-

-

... More
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. The makes of cable gland shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 3.5C x 95 sq mm A2XFY armoured AL Cable

4

-

-

... More
Providing and fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. The makes of cable gland shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 3.5C x 25 sq mm A2XFY armoured AL Cable

2

-

-

... More
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. The makes of cable gland shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO) 4C x 16 sq mm A2XFY armoured AL Cable

20

-

-

... More
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. The makes of cable gland shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 4C x 10 sq mm A2XFY armoured AL Cable

16

-

-

... More
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. The makes of cable gland shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 4C x 2.5 Sq.mm. 2XFY CU Cable

25

-

-

... More
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. The makes of cable lugs shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 3.5C x 300 sq mm A2XFY armoured AL Cable

10

-

-

... More
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. The makes of cable lugs shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 3.5C x 150 sq mm A2XFY armoured AL Cable

6

-

-

... More
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. The makes of cable lugs shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 3.5C x 95 sq mm A2XFY armoured AL Cable.

4

-

-

... More
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. The makes of cable lugs shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 3.5C x 25 sq mm A2XFY armoured AL Cable

8

-

-

... More
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. The makes of cable lugs shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 4C x 16 sq mm A2XFY armoured AL Cable

54

-

-

... More
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. The makes of cable lugs shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 4C x 10 sq mm A2XFY armoured AL Cable

32

-

-

... More
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. The makes of cable lugs shall be Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 4C x 2.5 Sq.mm. 2XFY CU Cable

50

-

-

... More
Supply, Installation, Testing and Commissioning of Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene (conforming to IS 14930 II) with necessary connecting accessories of same material at required depth for laying of cable. below ground/ road surface for enclosing cable and back filling the same to make ground as per original. The makes of DWC Pipe shall be Duraline, Rex or as approved by Chief Technical Officer (CTO). 120 MM OD

297

-

-

... More
Supply, Installation, Testing and Commissioning of Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene (conforming to IS 14930 II) with necessary connecting accessories of same material at required depth for laying of cable. below ground/ road surface for enclosing cable and back filling the same to make ground as per original. The makes of DWC Pipe shall be Duraline, Rex or as approved by Chief Technical Officer (CTO). 63 MM OD & ID 50 MM

666

-

-

... More
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable (16 bricks per meter)

963

-

-

... More
Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5 sq. mm & earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in /flushed on wall/ceiling , complete with 6A Tissino Type ISI marked flush type switch / bell push and accessories erected on Metal / PVC Box covered with 3 mm thick PC(Polycarbonet) /Acrylic sheet with 16 swg(1.6 mm thick) HGS metal conduit pipe and accessories painted black. The makes of Modular switches shall be Legrand, Crabtree, Clipsal, Anchor, MK or as approved by Chief Technical Officer (CTO).

40

-

-

... More
Supply, Installation, Testing and Commissioning of 36W LED flood lighting fixture for outdoor application (For External Area Lighting). The makes of Lighting fixtures shall be Wipro, Philips, Crompton Greaves, Bajaj ,Havel or as approved by Chief Technical Officer (CTO). (For 15 MLD Clear Water Pumping Station)

8

-

-

... More
Supply, Installation, Testing and Commissioning of 1.2mtr. Long, Single Arm Bracket on existing wall of pump room from outer side. (For 15 MLD Clear Water Pumping Station)

8

-

-

... More
Supply, Installation, Testing and Commissioning of 90W LED flood lighting fixture for outdoor application (For Roads, Transformer yard, bridge & area Lighting). The makes of Lighting fixtures shall be Wipro, Philips, Crompton Greaves, Bajaj, Havel or as approved by Chief Technical Officer (CTO). (PWD Pump House Area)

6

-

-

... More
Supply, Installation, Testing and Commissioning of 7.5 mtr. Long Swaged Steel tubular pole as per IS code 410-SP-4, confirming to IS - 2713 (Part-II) 1980. Manufacturing process of steel tubular pole should be as per IS specification. Basic steel tube should be ISI Marked. Pole should be painted by one coat of Zinc comet Primer and two coat of Aluminium /approved paint to be erected on / in existing Foundation. (Approximate Pole weight 67 Kg) The makes of Poles shall be Transrail, Valmont, Bajaj or as approved by Chief Technical Officer (CTO). ( PWD Pump House Area)

4

-

-

... More
Add Extra for M.S. Base plate 300 X 300 X 16 mm for pole, Suitable for mounting on surface of foundation with foundation bolts, with required stiffeners welded with pole.

4

-

-

... More
Add Extra for PU base primer and PU Paint on pole.

4

-

-

... More
Pole Founadation- The pole shall be provided in excavation and base 1 :4: 8 installed in cement concrete foundation (1:2:4) i. e. 1 cement, 2 coarse sand and 4 graded stone with the help of anchor bolts complete as required as per the directions of Engineer in charge.

4

-

-

... More
Supply, Installation, Testing and Commissioning of 40W LED Fixtures and associated fittings for Electrical/ Switchgear/ Control/ Office Room & Pump Room. The makes of Lighting fixtures shall be Wipro, Philips, Crompton Greaves, Bajaj ,Havel or as approved by Chief Technical Officer (CTO).

14

-

-

... More
Supply, Installation, Testing and Commissioning of 15W LED lighting fixture with all necessary fittings for indoor application (For Toilet, building entry point etc.) The makes of Lighting fixtures shall be Wipro, Philips, Crompton Greaves, Bajaj ,Havel or as approved by Chief Technical Officer (CTO).

4

-

-

... More
Supplying and fixing of the ceiling fans of approved make for electrical/Control room with 1200mm sweep, white color, double ball bearing, 300mm long down rod, Electronic type approved make regulator and accessories i.e. screws, wall nuts etc. The makes of Fans shall be Bajaj, Crompton, Havels or as approved by Chief Technical Officer (CTO).

7

-

-

... More
Supply, fixing and commissioning of 305 mm dia Exhaust fans including bird louvers, frame works and other civil works like chipping and making the surface good etc (Cat-I). The makes of Fans shall be Bajaj, Crompton, Havels or as approved by Chief Technical Officer (CTO).

14

-

-

... More
Supply, Installation, testing and commissioning of weatherproof Junction Boxes (with IP66 Protection) suitable for Loop-In Loop-Out & temination suitable for 2# 4 Core X 16 Sq.mm Al., XLPE, armoured cables and outgoing for 2 run flexible cu. cable. The junction boxes shall be dust/vermin/water proof shall be complete with removable cover plate & terminal blocks suitable for incomer and outgoing cable.The cable glands should be wetherproof.After testing and commissioning junction box to be filled with resin compound. [2] 250mm x 250mm x 60/75 mm depth. The makes of Junctions Box shall be Hensel, Fibox, Precision, Polycab or as approved by Chief Technical Officer (CTO).

14

-

-

... More
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection as desired by Engineer In charge. The makes of Modular switches shall be Legrand, Crabtree, Clipsal, Anchor, MK or as approved by Chief Technical Officer (CTO). (13) 6A/10A/16A/20A/25A/32A Single pole Modular MCB Switch, Cat.III

12

-

-

... More
Earthing-Supply, Installation, Testing and Commissioning of earth pit of minimum bore dia 150 mm size aproved make Safe Earthing Electrode consisting pipe-in pipe Technology made of corrosion free GI Pipe having outer pipe dia of 50 mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising connection terminal dia. of 12 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. For Electrical installation covering 11kV Switchgear, Transformers, Motors/ Starters, LV MCC Panel, PDB/ SDB & Lightning Protection System i.e. independent earthing in normal soil with Length of Pipe 3.00 mtr. & Back filling compound - 2 No. Bag of 25Kg each.

39

-

-

... More
Providing and Erecting required size of 25X6 mm Copper strip for earthing of electrical equipment i.e. Motor & Transformer Neutral earthing at a deth of 0.5m below ground as strip earth electrode, including termination/ interconnecting with GI Nut/Bolts, washer, Spring washer etc. as required. Jointing shall be done b yoverlapping & with two sets of Nut/ bolts and spring washer.

47

-

-

... More
Supply and Laying of 25X6mm GI strip at a depth of 0.5m below ground as strip earth electrode, including termination/ interconnecting with GI Nut/Bolts, washer, Spring washer etc. as required. Jointing shall be done b yoverlapping & with two sets of Nut/ bolts and spring washer spaced at 50mm apart for earthing for Panels, DBs and others.

267.96

-

-

... More
Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.

36.03

-

-

... More
Supplying and laying of rubber matting of 6 mm thickness as per IS 5424 and of required length and breadth with good insulation property for 11 KV for HV & LV Panels of required length and breath.

30

-

-

... More
Providing printed instruction chart both in English, Gujarati, Hindi and any other suggested language and duly framed with front glasses, for treatment of person suffering from Electric shock.

4

-

-

... More
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes).

2

-

-

... More
Supply, erection, testing and commissioning of Fire Bucket with 9 Litre Capacity etc complete as directed by Engineer in charge.

8

-

-

... More
Supply, erection, testing and commissioning of Fire Bucket Stand etc complete as directed by Engineer in charge.

2

-

-

... More
Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts grouted in wall complete. [A] For 5 Kg Capacity

6

-

-

... More
CSS for Clear Water Pumping Station- Supplying and Erecting approved make Compact Substation with 315 kVA,3 phase, 50 c/s ONAN TypeUNIPACK 21KA for 3 Sec. SF6 insulated Non-Extinsible Compact switchgear (Type DV-NE) consisting of one No. Direct Cable module and One No. Fixed Manual Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMTL + Inst.) protection. Interconnection between HT switchgear and transformer shall be using 1Cx3x150 sq.mm Al. unarmorured XLPE Cable.Copper wound transformer 315 KVA 11KV/433V Dyn11 Oil filled, INDOOR TYPE TRANSFORMER BUSHINGS,hermatically sealed transformer with corrugated wall,without conservator type of design & Top Normal Porcelein Bushings for HT & LT with Off load tap switch of rating +5% to -10% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel.Losses (Subject to IS 1180 Energy Efficiency level 2 - Max @ 50% Loading : As per IS 1180 and Max @ 100% Loading : As per IS 1180 and Impedanance As per IS 1180 with LV PANEL-500 AMPS ALUMINUM BUSBAR ( 100% for Phase and 50% for Neutral, Current Density - 1amp/sqmm) with Outgoings 500 Amps 433V 4P 50Hz 35KA ICOG Fixed Manual Type Moulded case Circuit Breaker (MCCB) with Microprocessor based release for Overload , short circuit & earth Fault protection., Multifunctional Meter with Class 1.0Accuracy with RS 485 Port, RYB, ON/OFF Trip Indications, OUTDOOR ENCLOSURE having IP54 IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment, Powder /Colour Coated Enclosure, with Interconnection Between HT switchgear & Transformer using 1Cx3x150 Sq.mm XLPE Aluminum Single core cable. Interconnection between Transformer & LT switchgear using Al. Busbars. Internal earthing connections by using 50x6 mm GI Strips including Transformer Neutral, Complete as per specification No SSTR/ COMP with necessary permission of Electrical Inspector. The makes of CSS shall be Schneider, ABB, Siemens, L&T or as approved by Chief Technical Officer (CTO).

1

-

-

... More
DG Set (For Clear Water Pumping Station)- Supplying, Erection, testing and commissioning of Silent type weather proof Diesel Generating set at site of following rating 415 Volts, 3 phase, 50 Hz. AC alternator coupled to Diesel Engine developing 600 BHP at 1500 RPM with AMF panel, complete with all accessories, standard specifications tool kit, service manual, self starting device, fly wheel, Silencer, coupling with guard, V belts, radiator, Instrument panel, control panel, Common bed plate, Anti vibration isolation pads, first charge of Engine Oil, Gear Oil, 12 volts chargeable battery set, battery charger etc. of the following ratings (Prime power). Rating- 500 kVA The makes of DG Set shall be Cummins, Kirloskar Oil Engines, Caterpillar, Greaves Ltd, Mitsubishi or as approved by Chief Technical Officer (CTO). Note: Each generator shall be complete with Electronic Governor, automatic voltage regulator, engine generator control and management system suitable for auto start, auto stop.

1

-

-

... More
Energy Audit before Start of Works- Cost towards Data Collection, Survey and Investigation & Measurements including equipment hiring/ purchase, labour charges, Key professional charges and submission of IGEA report as specified in Technical Specification. 1. To identify various public installations, assets and equipments of Pumping Stations and all other energy consuming assests within project area. 1. Data collection, Observation and assessment of current level operation and practices as specified in technical specification. 2.Energy consumption by type of energy, by department, by major items of process equipment, by end-use as specified in technical specification. 3. Energy cost and tariff data. 4. Pump and Motor condition assessment, Insulation and Lighting survey with portable instruments for collection and measurement data as specified in technical specification. 5. Fee of Key Personnel for carrying out Energy Audit and implementation of improvement measures under the specified scope and defined battery limits -Energy Auditor, Electrical Engineer, Mechanical engineer. 6. Preparation of Detailed IGEA Report as specified in technical specification and scope of works.

1

-

-

... More
Energy Audit after Execution of Works- Cost towards Data Collection, Survey and Investigation & Measurements including equipment hiring/ purchase, labour charges, Key professional charges and submission of IGEA report as specified in Technical Specification. 1. To identify various public installations, assets and equipment's of Pumping Stations and all other energy consuming assests within project area. 1. Data collection, Observation and assessment of current level operation and practices as specified in technical specification. 2.Energy consumption by type of energy, by department, by major items of process equipment, by end-use as specified in technical specification. 3. Energy cost and tariff data. 4. Pump and Motor condition assessment, Insulation and Lighting survey with portable instruments for collection and measurement data as specified in technical specification. 5. Fee of Key Personnel for carrying out Energy Audit and implementation of improvement measures under the specified scope and defined battery limits -Energy Auditor, Electrical Engineer, Mechanical engineer. 6. Preparation of Detailed IGEA Report as specified in technical specification and scope of works.

1

-

-

... More
15 MLD Intake Well - Supply, Installation, Testing Commissioning of Radar Level Transmitter at Intake well location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 30 M

1

-

-

... More
Supply, Installation, Testing Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO) Range 0-35 kg/cm2

2

-

-

... More
Supply, Installation, Testing Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Khrone Marshall, Siemens,E&H or as approved by Chief Technical Officer (CTO). Dia- 600 mm

1

-

-

... More
Supply, Installation, Testing Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Khrone Marshall, Siemens,E&H or as approved by Chief Technical Officer (CTO). Dia- 500 mm

1

-

-

... More
Supply, Installation, Testing Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

4

-

-

... More
Supply, Installation, Testing Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

4

-

-

... More
Cables & Cabling Accessories - Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Supply, Laying-Fixing-jointing and termination of 12 PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable

150

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing and termination of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

20

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray

50

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3 Mtr Long Cu Electrode for Electronic Earthing

2

-

-

... More
Supply, Installation, Testing and Commissioning of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc.Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2, 8 Channel AO Card =2, 8 Channel RTD Card =4 , Modbus Node=4, Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Technical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing and Commissioning of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
New 15 MLD WTP - Supply, Installation, Testing Commissioning of Ultrasonic Type Level Transmitter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 10 M

4

-

-

... More
Supply, Installation, Testing Commissioning of Ultrasonic type Open Channel Flow meter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 5 M

1

-

-

... More
Supply, Installation, Testing Commissioning of Glass Type Level Gauge with all necessary hardware and software Approved Make: ABB,Sapcon Levcon or as approved by Chief Technical Officer (CTO). Range 0- 3 M

2

-

-

... More
Supply, Installation, Testing Commissioning of PressureTransmitter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing Commissioning of Full bore type Electromagnetic Flow meter with all necessary hardware and software Approved Make: ABB, Khrone Marshall, Siemens,E&H or as approved by Chief Technical Officer (CTO). Dia- 300 mm

2

-

-

... More
Supply, Installation, Testing Commissioning of Full bore type Electromagnetic Flow meter with all necessary hardware and software Approved Make: ABB, Khrone Marshall, Siemens,E&H or as approved by Chief Technical Officer (CTO). Dia- 500 mm

2

-

-

... More
Supply, Installation, Testing Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm

8

-

-

... More
Supply, Installation, Testing Commissioning of Bypass Rotameter Approved Make: ABB, Yokogawa, Reliable or as approved by Chief Technical Officer (CTO). Range 0-2000 lph

2

-

-

... More
Supply, Installation, Testing Commissioning of Capacitive Loss of Head Transmitter with all necessary hardware and software Approved Make: ABB, Yokogawa, Reliable or as approved by Chief Technical Officer (CTO).

6

-

-

... More
Supply, Installation, Testing Commissioning of Ultrasonic Rate of Flow Transmitter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 5 M

6

-

-

... More
Supply, Installation, Testing Commissioning of pH Meter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 14 pH

2

-

-

... More
Supply, Installation, Testing Commissioning of Turbidity Meter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 400 NTU

4

-

-

... More
Supply, Installation, Testing Commissioning of Residual Chlorine Transmitter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 5 ppm

1

-

-

... More
Supply, Installation, Testing Commissioning of TDS Analyser with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 5 ppm

2

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

1250

-

-

... More
Supply, Laying-Fixing-jointing and termination of 12 PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

1400

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

1200

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

700

-

-

... More
Supply, Laying-Fixing-jointing of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing and termination of 6 core Single Mode FO Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

3000

-

-

... More
Supply, Installation, testing and Commissioning of 3 Mtr Long Cu Electrode for Electronoc Earthing , etc. complete. And As directed by Engineer-In-Charge.

2

-

-

... More
PLC, SCADA & Accessories for WTP & Main SCADA, Data Acquisition System Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). Local Processors & IO Modules 1. Redundant PLC based controller having the provision of GSM/GPRS conmnectivity, 2. IO Modules/ Rack,m, 3. 32 Channel DI card-32x24vdc )15 nos, 4.32 Ch DO card-32x24vdc 5 nos, 5. 8 Ch AI Card 8 X 4-20mA, Optically isolated 14 nos, 6. 8 Ch AO Card , Optically Isolated 3 & 8 no, 7.Panel and internal passive network accessories: The PLC mentioned above will be housed in IP42 rated panel . Approximate dimensions 800H*800W*800D. ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Technical Specification and to be provided as per the requirement.

1

-

-

... More
SCADA Supply, Installation, Testing and Commisiioning of 1. Operating work stations: Intel i5 Processor, 3.2 Ghz, 4 GB RAM, (1 TB HDD), 2.keyboard, mouse and 12" Monitor. 3. Printer 4. OPC/Modbus TCP/IP communication interface module 5. Engineering Laptop: Intel i5 processor, 1 , TB HDD, 4 GB RAM, DVD R/RW, Windows 7, 15" display

1

-

-

... More
Supply, Installation, Testing and Commisiioning of UPS System for Pumping Station UPS 15KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
For 11 MLD WTP - SITC of Ultrasonic Type Level Transmitter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 10 M

4

-

-

... More
SITC of Ultrasonic type Open Channel Flow meter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 5 M

1

-

-

... More
SITC of Glass Type Level Gauge with all necessary hardware and software Approved Make: ABB,Sapcon Levcon or as approved by Chief Technical Officer (CTO). Range 0- 3 M

2

-

-

... More
SITC of Pressure Transmitter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
SITC of Full bore type Electromagnetic Flow meter with all necessary hardware and software Approved Make: ABB, Khrone Marshall, Siemens,E&H or as approved by Chief Technical Officer (CTO). Dia- 300 mm

2

-

-

... More
SITC of Full bore type Electromagnetic Flow meter with all necessary hardware and software Approved Make: ABB, Khrone Marshall, Siemens,E&H or as approved by Chief Technical Officer (CTO). Dia- 500 mm

1

-

-

... More
SITC of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

8

-

-

... More
SITC of Bypass Rotameter Approved Make: ABB, Yokogawa, Reliable or as approved by Chief Technical Officer (CTO). Range 0-2000 lph

2

-

-

... More
SITC of Capacitive Loss of Head Transmitter with all necessary hardware and software Approved Make: ABB, Yokogawa, Reliable or as approved by Chief Technical Officer (CTO). Range 0- 3 M

6

-

-

... More
SITC of Ultrasonic Rate of Flow Transmitter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 5 M

6

-

-

... More
SITC of pH Meter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 14 Ph

2

-

-

... More
SITC of Turbidity Meter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 400 NTU

4

-

-

... More
SITC of Residual Chlorine Transmitter with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 5 ppm

1

-

-

... More
SITC of TDS Analyser with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 5 ppm

2

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

1250

-

-

... More
Supply, Laying-Fixing-jointing and termination of 12 PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

1400

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

1200

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

700

-

-

... More
Supply, Laying-Fixing-jointing and termination of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

20

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray

100

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing

2

-

-

... More
PLC, SCADA & Accessories for WTP & Main SCADA, Data Acquisition System Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). Local Processors & IO Modules 1. Redundant PLC based controller having the provision of GSM/GPRS connectivity 2. IO Modules/ Rack 3. 32 Channel DI card-32x24vdc )15 nos 4.32 Ch DO card-32x24vdc 5 nos 5. 8 Ch AI Card 8 X 4-20mA, Optically isolated 14 nos 6. 8 Ch AO Card , Optically Isolated 3 & 8 no 7.Panel and internal passive network accessories: The PLC mentioned above will be housed in IP42 rated panel . Approximate dimensions 800H*800W*800D. ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Technical Specification and to be provided as per the requirement.

1

-

-

... More
SITC of UPS System for Pumping Station - UPS15KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
21 LL UGSR cum PS - SITC of Ultrasonic Level Transmitter at GSR well location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 15 M

1

-

-

... More
SITC of Pressure Transmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
SITC of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 500 mm

2

-

-

... More
SITC of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

2

-

-

... More
SITC of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

2

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing and termination of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

60

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Panel accessories etc. Basic IO Count, 32 Channel DI Card =3, 32 Channel DO Card =2 ,, 8 Channel AI Card =2, 8 Channel AO Card =2, 8 Channel RTD Card =4, Modbus Node=4, Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Technical Specification and to be provided as per the requirement.

1

-

-

... More
SITC of FO cum Ethernet Switch , Other Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station - UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
21 LL UGSR cum PS - SITC of Ultrasonic Level Transmitter at GSR well location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 15 M

1

-

-

... More
SITC of PressureTransmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

2

-

-

... More
SITC of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 400 mm

1

-

-

... More
SITC of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 500 mm

2

-

-

... More
SITC of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

5

-

-

... More
SITC of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

5

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable, Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Deltonor as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

30

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Panel accessories etc. Basic IO Count, 32 Channel DI Card =3, 32 Channel DO Card =2, 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Technical Specification and to be provided as per the requirement.

1

-

-

... More
SITC of FO cum Ethernet Switch , Other Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station - UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system., Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
6 LL UGSR cum PS - SITC of Ultrasonic Level Transmitter at GSR well location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 15 M

1

-

-

... More
SITC of PressureTransmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
SITC of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 300 mm

2

-

-

... More
SITC of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

5

-

-

... More
SITC of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

5

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable, Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

120

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable, Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

200

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

60

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

2

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Panel accessories etc.Basic IO Count, 32 Channel DI Card =3, 32 Channel DO Card =2, 8 Channel AI Card =2, , 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Technical Specification and to be provided as per the requirement.

1

-

-

... More
SITC of FO cum Ethernet Switch , Other Communication Cable and Communication Accessories, Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station - UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Tokarkhada UGSR cum PH - SITC of Ultrasonic Level Transmitter at GSR well location with all necessary hardware and software, Approved Make: ABB, Forbes Marshall, Siemensor as approved by Chief Technical Officer (CTO). Range 0- 15 M

1

-

-

... More
SITC of Pressure Transmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
SITC of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software. Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 200 mm

2

-

-

... More
SITC of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

1

-

-

... More
SITC of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

1

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

30

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc complete and as directed by Engineer-In-Charge.

15

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

15

-

-

... More
Supply, Installation, Testing and Commissioning of 3 Mtr Long Cu Electrode for Electronic Earthing.

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Panel accessories etc.Basic IO Count, 32 Channel DI Card =3, 32 Channel DO Card =2, 8 Channel AI Card =2 , 8 Channel AO Card =2 , 8 Channel RTD Card =4 , Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Technical Specification and to be provided as per the requirement.

1

-

-

... More
SITC of FO cum Ethernet Switch , Other Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station - UPS15KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
ESR-12LL - SITC of Ultrasonic Level Transmitter with Battery operated GPRS Datalogger Unit (Range 0-10 M) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet(Dia 400 mm), Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
ESR-26 LL - SITC of Ultrasonic Level Transmitter with Battery operated GPRS Datalogger Unit (Range 0-10 M) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet (Dia 400 mm) , Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet(Dia 400 mm) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
ESR-1.5 LL/ 5 LL new - SITC of Ultrasonic Level Transmitter with Battery operated GPRS Datalogger Unit (Range 0-10 M) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet (Dia 400 mm) , Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet (Dia 400 mm) , Approved Make: ABB, Forbes Marshall, Siemensor as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shielded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
For 5 LL ESR - SITC of Ultrasonic Level Transmitter with Battery operated GPRS Datalogger Unit (Range 0-10 M) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet(Dia 200 mm) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO)

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet(Dia 200 mm) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO)

1

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shielded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
For ESR 10 LL - SITC of Ultrasonic Level Transmitter with Battery operated GPRS Datalogger Unit (Range 0-10 M) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet (Dia 400 mm) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet (Dia 400 mm) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shielded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
For 10 LL ESR - SITC of Ultrasonic Level Transmitter with Battery operated GPRS Datalogger Unit (Range 0-10 M) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet(Dia 400 mm) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Outlet (Dia 400 mm)

1

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shielded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
For 10 LL ESR - SITC of Ultrasonic Level Transmitter with Battery operated GPRS Datalogger Unit (Range 0-10 M) Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). (Dia 400 mm)

1

-

-

... More
SITC of Battery Operated Electromagnetic Flow Meter with Inbuilt GPRS Modem at Outlet Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). (Dia 400 mm)

1

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shielded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

100

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

50

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
New Pump House - SITC of Ultrasonic Level Transmitter at GSR well location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0- 15 M

1

-

-

... More
SITC of Pressure Transmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
SITC of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO) Dia- 450 mm.

1

-

-

... More
SITC of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

4

-

-

... More
SITC of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

4

-

-

... More
Supply, Laying-Fixing-jointing and termination of Single PairX 1 Sqmm. Stranded Cu, Shielded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

30

-

-

... More
Supply, Laying-Fixing-jointing and termination of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Supply, Laying-Fixing-jointing of 50 X 50, GI Perforated, with Cover Cable Tray, etc. complete and as directed by Engineer-In-Charge.

30

-

-

... More
Supply, Laying-Fixing-jointing of 3 Mtr Long Cu Electrode for Electronic Earthing, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Panel accessories etc. , Basic IO Count, 32 Channel DI Card =3, 32 Channel DO Card =2, 8 Channel AI Card =2, 8 Channel AO Card =2 , 8 Channel RTD Card =4, 8 Channel RTD Card =4, Modbus Node=4, Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO) ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Technical Specification and to be provided as per the requirement.

1

-

-

... More
SITC of FO cum Ethernet Switch , Other Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Communication Cable and Communication Accessories, etc. complete and as directed by Engineer-In-Charge.

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system., Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of Battery Powered Full bore type Electromagnetic Flow meter with Internal/External Modem at Distribution Line with all necessary hardware and software complete of Following Dia Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). 50 MM

1

-

-

... More
80 mm

2

-

-

... More
100 mm

22

-

-

... More
150 mm

26

-

-

... More
200 mm

10

-

-

... More
250 mm

13

-

-

... More
300 mm

3

-

-

... More
350 mm

2

-

-

... More
400 mm

4

-

-

... More
500 mm

2

-

-

... More
SITC of Pressure Transmitter at Distribution Line with all necessary hardware and software complete of Following Range, Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 Kg/cm2

85

-

-

... More
SITC of Dual Channel Battery Powered Datalogger Unit at Distribution Line with all necessary hardware and software complete for Powering and Data Transmission from Pressure Transmitter, Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).

86

-

-

... More
SITC of PLC Based RTU Unit for Valve Remote Operation, etc. complete as approved by Chief Technical Officer (CTO).

16

-

-

... More
Domestic Water Meter Works - SITC of AMR Electromagnetic type Domestic Water Meter with All necesssary Hardware & Software complete as per Technical Specification mentioned in Technical Specification of RFP Approved Make: Xylem/Sensus, Electronet as approved by Chief Technical Officer (CTO). Dia 15 mm

8291

-

-

... More
SITC of AMR Electromagnetic type Domestic Water Meter with All necesssary Hardware & Software complete as per Technical Specification mentioned in Technical Specification of RFP Approved Make: Xylem/Sensus,Electronet as approved by Chief Technical Officer (CTO). Dia 20 mm

83

-

-

... More
SITC of AMR Electromagnetic type Domestic Water Meter with All necesssary Hardware & Software complete as per Technical Specification mentioned in Technical Specification of RFP Approved Make: Xylem/Sensus, Electronet as approved by Chief Technical Officer (CTO). Dia 25 mm

112

-

-

... More
SITC of AMR Electromagnetic type Domestic Water Meter with All necesssary Hardware & Software complete as per Technical Specification mentioned in Technical Specification of RFP Approved Make: Xylem/Sensus, Electronet as approved by Chief Technical Officer (CTO). Dia 40 mm

147

-

-

... More
SITC of AMR Electromagnetic type Domestic Water Meter with All necesssary Hardware & Software complete as per Technical Specification mentioned in Technical Specification of RFP Approved Make: Xylem/Sensus, Electronet as approved by Chief Technical Officer (CTO). Dia 50 mm

106

-

-

... More
SITC of AMR Electromagnetic type Domestic Water Meter with All necesssary Hardware & Software complete as per Technical Specification mentioned in Technical Specification of RFP Approved Make: Xylem/Sensus, Electronet as approved by Chief Technical Officer (CTO). Dia 80 mm

11

-

-

... More
SITC of Required Hardwares and Fittings, Pipes, Valves for Water Meter for all the required dia of Domestic House Service Connection including works excavation, refilling, labour charges in all the soil strata (blasting prohibited) including all the necessary works to complete the fixing of meter and as directed by engineer in charge etc complete.

8750

-

-

... More
SITC of HDPE/PP Water Meter Box with accessories complete for all the required dia of Domestic House Service Connection Water Meter including required excavation, refilling, labour charges for all the soil strata (blasting prohibited) including all the necessary works to complete the fixing of meter and as directed by engineer in charge etc complete.

8750

-

-

... More
RF Based Hand Held Device with GSM/GPRS Connectivity with All necesssary Hardware & Software complete as per Technical Specification mentioned in Technical Specification of RFP Approved Make: Xylem/Sensus, Electronet as approved by Chief Technical Officer (CTO).

4

-

-

... More
SITC of AMR Meter Reading Software as per Technical Specification mentioned in Technical Specification of RFP

1

-

-

... More
SITC of Billing Management Software as per Technical Specification mentioned in Technical Specification of RFP.

1

-

-

... More
SITC of PC System for AMR Software and Billing Software as per technical specification mentioned in Technical specification in RFP. Approved Make: IBM,Dell,HP as approved by Chief Technical Officer (CTO).

2

-

-

... More
OPERATION & MAINTENANCE OF ALL TYPES OF ELECTRICAL AND INSTRUMENTATION INSTRUMENTS FOR WATER SUPPLY DISTRIBUTION SYSTEM, RESERVOIRS, ALL PIPE NETWORK INCLUDING OPERATION OF VALVES ETC. FOR SILVASSA WATER SUPPLY SCHEME. Bill generation and distribution, billing software integrated with server at WTP server room. The work of O&M will consist of operation and maintenance of Electro-Mechanical, Electrical, Mechanical, Electronics equipment / item, Instruments, Record keeping, measuring devices. Civil work's maintenance of WDS, ESR and recharge borewells 86 nos. in SMC area. The firm has to operate the pumps as per municipal requirements. The firms has to repair or replace pumps, motors, valves & pipes (All Diameters), electrical work including day to day maintenance as well as preventive maintenance as per tender specification and directed by Engineer In Charge. The work also includes operation and maintenance of MS / DI / CI/ HDPE / PVC transmission pipeline, rising main and distribution network. The firm has to repair or replace pipes / specials and all type of valves including repairing of leakages and solving of contamination problems, ensure water quality as per slandered norms and repair to breakage of pipes, road and other utility restoration and valve chambers. Work also includes day to day maintenance as well as periodical preventive maintenance of all kind of valves. Item included gardening and plantation and the maintence of the same at all WDS and ESR plots - Also includes training to SMC Staff twice a year. The work also includes, monthly measurement of NRW-UFW, volumetric measurement of water distribution in each DMA, reduction of NRW as per SLBM norms of MoHUA, Maintain drinking water quality as per CPHEEO standard eg chlorine dose should be 0.2 ppm at tail end etc. complete. 24 X 7 water supply distribution, Works also includes PLC and SCADA operation and its maintenance. Manpower establishment and other works. Operator (ITI - Fitter 3 years experience in Similar Nature of works) 16 Nos, Lineman (ITI with 3 years experience in Similar Nature of works)- 8 nos, Water Supply Engineer (BE -Civil with 5 Years of Similar Works Experience) - 1 No, Plumber (ITI -Civil with 3 years experience in plumbing works) = 2 nos, Electrician (ITI -Electrical with 3 years experience in electrical works) - 1 No, Bidder has to quote rate based on above mentioned, establishment, chemicals and cost of pipe replacement for O & M part of entire water supply scheme for 10 years duration. Replacement of pipes and all routine and preventive maintenance as specified in the scope of works etc., complete. Cost is including Providing, lowering, laying, jointing, fixing, of pipes, valves and other pipe appurtenances, valve chamber with chamber covers including necessary excavations and refilling with restoration work. This cost is also inclusive of labour cost for execution of necessary work. The scope also includes regular preventive checks for all the civil structures and pipe works as directed by Engineer-In-Charge. O&M Cost of Distribution System Operation and maintenance charges for running of water supply scheme for 24 X 7 water supply. Providing and supplying manpower for O & M as per requirement for daily operation and maintenance of water treatment plant including Civil,electromechanical works, Civil maintenance of WTP including all chemical charges, eg Alum, chlorination system .Payment of manpower will be as per actual deployment of staff with name and grade. Outlet Quality of water should be as per norms of potable water given in latest CPHEEO manual as well as IS 10500. Following sub works are covered in this O & M. Intake well pump house, WTP 3 nos, pump house. Raw water and pure water rising main, Pumping machinery, PLC and SCADA for WTP including necessary watching grading operation for entire WTP premises, etc. as directed by Engineer in charge, Excluding cost of electricity bill, Electric bill for WTP, Intake well and pump house will be borne by SMC. The provision for extra emergency storage of Alum and chlorine toner shall be made by bidder and Engineer-In-charge have right to check the chemical inventory check. Cost of Chemical: Alum Requirement @ 30 mg/l (900 kg / Day), Chlorine Requirement @ 5 mg/lit (150 kg / Day), Lab. Chemicals for daily water quality monitoring, Petrol for owned Bike of Contractor's Meter Data Collector to complete Meter reading task including maintenance and others expenses complete Minimum Labour Requirement for O & M:Plant Manager- 1No (BE - Environment with min. 5 Years of experience in O&M of WTPs, Head Works), Chemist -4 Nos (B-Sc.-Chemistry with min. 3 years of experience in Similar laboratory Works), Mechanic - 2 Nos (ITI - Mechanical with 3 years experience in Mechanical works), Electrician - 2Nos (ITI -Electrical with 3 years experience in Electrical works), Operator - 5 Nos (ITI - Fitter 3 years experience in Similar Nature of works), Watchman cum Security - 3 Nos (X std passed with min. 3 years of work experience), Housekeeping -3 Nos (X std passed with minimum 3 years of work experience), Meter Data Collector (Diploma Electrical/Instrumentation)-3 Nos. for Meter Data Collection & Data Feeding to Billing Software, Computer Operator cum Bill Distributor - 1No (ITI - Computer with min. 2 yrs. Experience), M&R cost for WTP (3 Nos.) and Water HW: Civil Works Cost for 3 Nos. of WTPs (4, 15, 11 MLD), Raw and Clear Water Head works, UG Sump and ESRs, Mechanical, Electrical & Instrumentation Works for 3 Nos. of WTPs (4, 15, 11 MLD), Raw and Clear Water Head works, UG Sump and ESRs , Annual Maintenance cost for Water Meter Spare and Tools & Tackles for 10 Years Bidder has to quote rate based on above mentioned, establishment, chemicals and cost of pipe replacement for O & M part of entire water supply scheme for 10 years duration. (EXISTING SYSTEM: Total O&M Cost for 1st Year) Note: In addition to above Contractor shall Operate & Maintain newly installed system / completed works during 1 st Year of construction period.

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 2nd Year Note: In addition to above Contractor shall Operate & Maintain newly installed system / completed works during 1 st & 2nd Year of construction period.

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 3rd Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 4th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 5th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 6th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 7th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 8th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 9th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 10th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 3rd Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 4th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 5th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 6th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 7th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 8th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 9th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 10th Year

1

-

-

... More
Energy Audit after 3 Years- Cost towards Data Collection, Survey and Investigation & Measurements including equipment hiring/ purchase, labour charges, Key professional charges and submission of IGEA report as specified in Technical Specification. 1. To identify various public installations, assets and equipments of Pumping Stations and all other energy consuming assests within project area. 1. Data collection, Observation and assessment of current level operation and practices as specified in technical specification. 2.Energy consumption by type of energy, by department, by major items of process equipment, by end-use as specified in technical specification. 3. Energy cost and tariff data. 4. Pump and Motor condition assessment, Insulation and Lighting survey with portable instruments for collection and measurement data as specified in technical specification. 5. Fee of Key Personnel for carrying out Energy Audit and implementation of improvement measures under the specified scope and defined battery limits -Energy Auditer, Electrical Engineer, Mechanical engineer. 6. Prepartion of Detailed IGEA Report as specified in technical specification and scope of works.

1

-

-

... More
Energy Audit after 6 Years- Cost towards Data Collection, Survey and Investigation & Measurements including equipment hiring/ purchase, labour charges, Key professional charges and submission of IGEA report as specified in Technical Specification. 1. To identify various public installations, assets and equipments of Pumping Stations and all other energy consuming assests within project area. 1. Data collection, Observation and assessment of current level operation and practices as specified in technical specification. 2.Energy consumption by type of energy, by department, by major items of process equipment, by end-use as specified in technical specification. 3. Energy cost and tariff data. 4. Pump and Motor condition assessment, Insulation and Lighting survey with portable instruments for collection and measurement data as specified in technical specification. 5. Fee of Key Personnel for carrying out Energy Audit and implementation of improvement measures under the specified scope and defined battery limits -Energy Auditor, Electrical Engineer, Mechanical engineer. 6. Preparation of Detailed IGEA Report as specified in technical specification and scope of works.

1

-

-

... More
Energy Audit after 9 Years- Cost towards Data Collection, Survey and Investigation & Measurements including equipment hiring/ purchase, labour charges, Key professional charges and submission of IGEA report as specified in Technical Specification. 1. To identify various public installations, assets and equipments of Pumping Stations and all other energy consuming assests within project area. 1. Data collection, Observation and assessment of current level operation and practices as specified in technical specification. 2.Energy consumption by type of energy, by department, by major items of process equipment, by end-use as specified in technical specification. 3. Energy cost and tariff data. 4. Pump and Motor condition assessment, Insulation and Lighting survey with portable instruments for collection and measurement data as specified in technical specification. 5. Fee of Key Personnel for carrying out Energy Audit and implementation of improvement measures under the specified scope and defined battery limits -Energy Auditor, Electrical Engineer, Mechanical engineer. 6. Preparation of Detailed IGEA Report as specified in technical specification and scope of works.

1

-

-

... More
Dismantling of Existing 4MLD WTP and allied Civil and electromechanical works, treated water reservoir, pump house, office building, 11 Lakh litre ESR

1

-

-

... More
RCC GSR (10 to 20 Lakh Litres)- Preparing structural design of RCC Under Ground / Partially under ground / above high ground level Reservoir of required capacity as per relevant I.S. standards and constructing the same, including excavation in all types of soil strata (including rock) including shoring strutting if required, for loose soil / to protect from collapse, casting 100 mm thick P.C.C. levelling course in M- 15, Refilling the pit with proper soil and disposing of the surplus stuff at all lead. Including cement plaster in CM 1:2 with approved water proofing compound to all over inside container (i.e. walls, base, top slab/dome bottom etc. all). Including all types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design. Providing and fixing accessories, CI Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail. RCC chambers for valves. Providing and applying three coats of cement paint / snowcem to the out side face of structure. It also includes satisfactory water tightness test as per relevant I.S. code and painting name of scheme and capacity on the tank as per direction of engineer in charge. (for details specification for this work refer Tender Vol-III_B_B2)

0.01

-

-

... More
Sewerage network system

-

-

-

... More
1) Traversing easting northing point every 500m interval by DGPS instrument 2) TBM marks every 500m interval by auto level 3) 80 km sewerage network survey (of proposed network and network in extended area) by Total station and DGPS instrument (Road width, Type of road, culvert, Manholes, Connection chambers, and preparing L section drawing indicating manhole GL/ IL and Chambers G.L/ I.L/ every 20m interval)

80

-

-

... More
Collection Data of every property Septic tank/ Toilet chamber location with their G.L and Invert Level ground level and tank invert level by Total station and preparing the map of each property connection details with common/ individual chamber location with GL/ IL and connection to nearest manhole in the Network- per chamber nos.

9000

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-For Sewer pipes in all sort of soils and soft murrum, hard murrum, boulders including macadam roads, soft rock, masonry in CM or LM or Lime concrete, Hard rock with blasting and chiselling or by chiselling only for finishing. Excavation upto 0 to 1.5m depth

153503.3

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-For Sewer pipes in all sort of soils and soft murrum, hard murrum, boulders including macadam roads, soft rock, masonry in CM or LM or Lime concrete, Hard rock with blasting and chiselling or by chiselling only for finishing. Excavation upto 1.5 to 3m depth

34178.8

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-For Sewer pipes in all sort of soils and soft murrum, hard murrum, boulders including macadam roads, soft rock, masonry in CM or LM or Lime concrete, Hard rock with blasting and chiselling or by chiselling only for finishing. Note- Rates are inclusive of dewatering charges also- Excavation upto 3 to 4.5m depth

5846.6

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.-For Sewer pipes in all sort of soils and soft murrum, hard murrum, boulders including macadam roads, soft rock, masonry in CM or LM or Lime concrete, Hard rock with blasting and chiselling or by chiselling only for finishing. Note- Rates are inclusive of dewatering charges also- Excavation upto 4.5 to 6m depth

650.6

-

-

... More
Excavation in bituminous road as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts as specified.

1204.9

-

-

... More
Dewatering by pumping set of required capacity including temporary platform carting pumping at site and fixing the same in position including all accessories and fuel and labour etc. complete during execution of work Using 7.5 HP pump

510

-

-

... More
Shoring or timbering including cost of local wood material- Shoring or timbering for trench with 50 mm thick planks and suitable size struts etc. complete.

66481.5

-

-

... More
Providing bedding incl. ramming, watering, levelling, consolidating etc. complete as per standard and instruction of engineer in-charge- As above with required quality Sand brought from outside including all lead.

11768.8

-

-

... More
R C. C (Horizontally Cast) - Pipe-Providing and supplying ISI Standard and ISI marked R.C.C. pipes (of Sulphate Resisting Cement) in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc., complete. (IS - 458/ 1989) Note: One collar should be supplied with each full length plain ended RCC pipe, cost included in rates below. One rubber ring should be supplied with each full length socketed pipe, cost included in rates below.Class NP3 Test Pressure 0.7 Kg/sq.cm- 200 mm dia. Pipe

24810

-

-

... More
R C. C (Horizontally Cast) - Pipe-Providing and supplying ISI Standard and ISI marked R.C.C. pipes (of Sulphate Resisting Cement) in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc., complete. (IS - 458/ 1989) Note: One collar should be supplied with each full length plain ended RCC pipe, cost included in rates below. One rubber ring should be supplied with each full length socketed pipe, cost included in rates below.Class NP3 Test Pressure 0.7 Kg/sq.cm- 250 mm dia. Pipe

1493

-

-

... More
R C C ( Horizontally Cast- Pipe-Providing and supplying ISI Standard and ISI marked R.C.C. pipes (of Sulphate Resisting Cement) in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc., complete. (IS - 458/ 1989) Note: One collar should be supplied with each full length plain ended RCC pipe, cost included in rates below. One rubber ring should be supplied with each full length socketed pipe, cost included in rates below.Class NP3 Test Pressure 0.7 Kg/sq.cm- 300 mm dia. Pipe

921

-

-

... More
R C. C (Horizontally Cast-Providing and supplying ISI Standard and ISI marked R.C.C. pipes (of Sulphate Resisting Cement) in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc., complete. (IS - 458/ 1989) Note: One collar should be supplied with each full length plain ended RCC pipe, cost included in rates below. One rubber ring should be supplied with each full length socketed pipe, cost included in rates below.Class NP3 Test Pressure 0.7 Kg/sq.cm- 350 mm dia. Pipe

78

-

-

... More
R C. C (Horizontally Cast-Providing and supplying ISI Standard and ISI marked R.C.C. pipes (of Sulphate Resisting Cement) in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc., complete. (IS - 458/ 1989) Note: One collar should be supplied with each full length plain ended RCC pipe, cost included in rates below. One rubber ring should be supplied with each full length socketed pipe, cost included in rates below.Class NP3 Test Pressure 0.7 Kg/sq.cm- 400 mm dia. Pipe

538

-

-

... More
R C. C ( Horizontally Cast-Providing and supplying ISI Standard and ISI marked R.C.C. pipes (of Sulphate Resisting Cement) in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc., complete. (IS - 458/ 1989) Note: One collar should be supplied with each full length plain ended RCC pipe, cost included in rates below. One rubber ring should be supplied with each full length socketed pipe, cost included in rates below.Class NP3 Test Pressure 0.7 Kg/sq.cm- 450 mm dia. Pipe

384

-

-

... More
L,L& J of R.C.C. Pipes- NP3, NP4-Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following diameters in proper position, grade and alignment at all level as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per IS code. 200 mm dia. Pipe

24810

-

-

... More
L,L& J of R.C.C. Pipes- NP3, NP4-Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following diameters in proper position, grade and alignment at all level as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per IS code. 250 mm dia. Pipe

1493

-

-

... More
L,L& J of R.C.C. Pipes- NP3, NP4-Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following diameters in proper position, grade and alignment at all level as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per IS code. 300 mm dia. Pipe

371

-

-

... More
L,L& J of R.C.C. Pipes- NP3, NP4-Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following diameters in proper position, grade and alignment at all level as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per IS code. 350 mm dia. Pipe

78

-

-

... More
L,L& J of R.C.C. Pipes- NP3, NP4-Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following diameters in proper position, grade and alignment at all level as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per IS code. 400 mm dia. Pipe

538

-

-

... More
L,L& J of R.C.C. Pipes- NP3, NP4-Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following diameters in proper position, grade and alignment at all level as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per IS code. 450 mm dia. Pipe

384

-

-

... More
Labour charges for repairing of leakage in MS pipeline of following diameter at different places including necessary excavation manually or by machinery, dewatering, removing of mud, cleaning of pipe and leakage portion, grinding, cutting the pipeline or joint if necessary incl. welding the joint by using ISI marked welding rods duly approved by EIC of appropriate number and size inclusive of excavator, Hydra/ Crane, D.G. set, welding machine, Gas cutter with LPG Cylinder, Oxygen cylinder, Grinding machine etc. with fuel, operator & labour as required. (incl. all material but excluding cost of pipe) 168.30 mm

30

-

-

... More
Labour charges for repairing of leakage in MS pipeline of following diameter at different places including necessary excavation manually or by machinery, dewatering, removing of mud, cleaning of pipe and leakage portion, grinding, cutting the pipeline or joint if necessary incl. welding the joint by using ISI marked welding rods duly approved by EIC of appropriate number and size inclusive of excavator, Hydra/ Crane, D.G. set, welding machine, Gas cutter with LPG Cylinder, Oxygen cylinder, Grinding machine etc. with fuel, operator & labour as required. (incl. all material but excluding cost of pipe) 193.70 mm

30

-

-

... More
Labour charges for repairing leakage in CI/DI pipeline of following diameter at different places including necessary excavation manually or by machinery, removing of mud, dewatering, cleaning of pipe, cutting of pipe, Jointing & repairing using CID joints including CID joints, rubber rings, nut bolts, hiring excavator, Hydra/ Crane, dewatering machine, fuel, operator etc complete (including cost of jointing material but excluding cost of pipe) 80 mm

25

-

-

... More
Labour charges for repairing leakage in CI/DI pipeline of following diameter at different places including necessary excavation manually or by machinery, removing of mud, dewatering, cleaning of pipe, cutting of pipe, Jointing & repairing using CID joints including CID joints, rubber rings, nut bolts, hiring excavator, Hydra/ Crane, dewatering machine, fuel, operator etc complete (including cost of jointing material but excluding cost of pipe) 100 mm

15

-

-

... More
Labour charges for repairing leakage in CI/DI pipeline of following diameter at different places including necessary excavation manually or by machinery, removing of mud, dewatering, cleaning of pipe, cutting of pipe, Jointing & repairing using CID joints including CID joints, rubber rings, nut bolts, hiring excavator, Hydra/ Crane, dewatering machine, fuel, operator etc complete (including cost of jointing material but excluding cost of pipe) 125 mm

15

-

-

... More
Labour charges for repairing of leakage in PVC pipeline of following dia meter at different places including necessary excavation manually or by mechanise excavation, dewatering removing of mud, cleaning of pipe and leakage portion, cutting the pipeline & removing piece of pipe from trench with inclusive of mechanical devices JCB, Hydra/Crain if necessary & labours required with providing material such couplers, solution etc. comp. (incl. all material but Exclu. cost of pipe) 90 mm

15

-

-

... More
Labour charges for repairing of leakage in PVC pipeline of following dia meter at different places including necessary excavation manually or by mechanise excavation, dewatering removing of mud, cleaning of pipe and leakage portion, cutting the pipeline & removing piece of pipe from trench with inclusive of mechanical devices JCB, Hydra/Crain if necessary & labours required with providing material such couplers, solution etc. comp. (incl. all material but Exclu. cost of pipe) 110 mm

15

-

-

... More
Labour charges for repairing of leakage in PVC pipeline of following dia meter at different places including necessary excavation manually or by mechanise excavation, dewatering removing of mud, cleaning of pipe and leakage portion, cutting the pipeline & removing piece of pipe from trench with inclusive of mechanical devices JCB, Hydra/Crain if necessary & labours required with providing material such couplers, solution etc. comp. (incl. all material but Exclu. cost of pipe) 140 mm

25

-

-

... More
Labour charges for repairing of leakage in PVC pipeline of following dia meter at different places including necessary excavation manually or by mechanise excavation, dewatering removing of mud, cleaning of pipe and leakage portion, cutting the pipeline & removing piece of pipe from trench with inclusive of mechanical devices JCB, Hydra/ Crain if necessary & labours required with providing material such couplers, solution etc. comp. (incl. all material but Exclu. cost of pipe) 160 mm

20

-

-

... More
Labour charges for repairing of leakage in HDPE pipe line with butt welding of following diameter at different places including necessary excavation manually or by mechanize excavation, dewatering, removing of mud, cleaning of pipe and leakage portion of pipe from trench with incl. of mechanical deviced JCB if necessary and labours required with providing, jointing material with welding machine etc. comp. (incl. all materials)- 160 mm dia

15

-

-

... More
Labour charges for repairing of leakage in HDPE pipe line with butt welding of following diameter at different places including necessary excavation manually or by mechanize excavation, dewatering, removing of mud, cleaning of pipe and leakage portion of pipe from trench with incl. of mechanical deviced JCB if necessary and labours required with providing, jointing material with welding machine etc. comp. (incl. all materials)- 200 mm dia

20

-

-

... More
Labour charges for repairing of leakage in HDPE pipe line with butt welding of following diameter at different places including necessary excavation manually or by mechanize excavation, dewatering, removing of mud, cleaning of pipe and leakage portion of pipe from trench with incl. of mechanical deviced JCB if necessary and labours required with providing, jointing material with welding machine etc. comp. (incl. all materials)- 225 mm dia

20

-

-

... More
Labour charges for repairing of leakage in HDPE pipeline of following diameter at different places including necessary excavation manually or by machinery, dewatering, removing of mud, cleaning of pipe and leakage portion, Jointing & repairing using MS Clamp inclusive of using all required machinery, labour, dewatering set, fuel, operator, rubber sheet, all Jointing materials, nut bolts etc complete (but excluding cost of Pipe)- 280mm

15

-

-

... More
Labour charges for repairing of leakage in HDPE pipeline of following diameter at different places including necessary excavation manually or by machinery, dewatering, removing of mud, cleaning of pipe and leakage portion, cutting the pipeline, Jointing & repairing using CID joint inclusive of using all required machinery, labour, D G Set, fuel, operator, CID joints, rubber rings, nut bolts etc complete (but excluding cost of Pipe)- 315mm

10

-

-

... More
Labour charges for repairing of leakage in HDPE pipeline of following diameter at different places including necessary excavation manually or by machinery, dewatering, removing of mud, cleaning of pipe and leakage portion, cutting the pipeline, Jointing & repairing using CID joint inclusive of using all required machinery, labour, D G Set, fuel, operator, CID joints, rubber rings, nut bolts etc complete (but excluding cost of Pipe)- 400mm

20

-

-

... More
Cable Repairing- Electric/ Telephone cable

20

-

-

... More
Tracing of Old Manholes (All Types)

8

-

-

... More
Refilling of pipeline trenches: Refilling the pipeline trenches incl. ramming, watering, consolidating disposal of surplus stuff as directed within a radius of 3 km. Refilling as directed.

117785.6

-

-

... More
Refilling of pipeline trenches: Refilling the pipeline trenches incl. ramming, watering, consolidating disposal of surplus stuff as directed within a radius of 3 km. Refilling with selected soil brought from outside including all lead.

46781.6

-

-

... More
Providing and constructing Sewer manholes, scraper manholes and unit house connection chamber, as per the type design in brick masonry in C. M. 1:5 and inside and outside 20mm thick plastering in C. M. 1:3 necessary 100 mm coping with reinforcement in R.C.C. M 200 fixing C. I. steps and fixing manhole frame and covers (But excluding supply of manhole frame and covers) over manholes and house connection chambers and fixing Manhole covers (but excluding supplying of manhole covers) over scraper manhole etc. complete, providing and fixing safety chain wherever necessary as per the stipulations in the type design complete as per latest CPHEEO manual. (excl. excavation). Manhole type "A" Circular type having inside diameter of 1200 mm for depth upto 1.5 m depth (for 150 mm to 500 mm dia sewer). Manhole type "A" as above but upto 1.0 M. (The required additional manholes as provision for road crossing locations for replacement of existing pipeline as included in the BoQ. These manholes are in addition to those required in sewerage system.)

268

-

-

... More
Providing and constructing Sewer manholes, scraper manholes and unit house connection chamber, as per the type design in brick masonry in C. M. 1:5 and inside and outside 20mm thick plastering in C. M. 1:3 necessary 100 mm coping with reinforcement in R.C.C. M 200 fixing C. I. steps and fixing manhole frame and covers (But excluding supply of manhole frame and covers) over manholes and house connection chambers and fixing Manhole covers (but excluding supplying of manhole covers) over scraper manhole etc. complete, providing and fixing safety chain wherever necessary as per the stipulations in the type design complete as per latest CPHEEO manual. (excl. excavation). Manhole type "A" Circular type having inside diameter of 1200 mm for depth upto 1.5 m depth (for 150 mm to 500 mm dia sewer). Extra depth beyond 1.0 M but upto 1.5 M depth for "A" type manhole above.

126.7

-

-

... More
Providing and constructing Sewer manholes, scraper manholes and unit house connection chamber, as per the type design in brick masonry in C. M. 1:5 and inside and outside 20mm thick plastering in C. M. 1:3 necessary 100 mm coping with reinforcement in R.C.C. M 200 fixing C. I. steps and fixing manhole frame and covers (But excluding supply of manhole frame and covers) over manholes and house connection chambers and fixing Manhole covers (but excluding supplying of manhole covers) over scraper manhole etc. complete, providing and fixing safety chain wherever necessary as per the stipulations in the type design complete as per latest CPHEEO manual. (excl. excavation). Manhole type "B" circular type having inside diameter of minimum 1500 mm and for depth from 1.5 M to 4.0 M (for 150 mm to 600 mm dia sewers) Manhole type "B" as above but upto 1.5 M depth.

960

-

-

... More
Providing and constructing Sewer manholes, scraper manholes and unit house connection chamber, as per the type design in brick masonry in C. M. 1:5 and inside and outside 20mm thick plastering in C. M. 1:3 necessary 100 mm coping with reinforcement in R.C.C. M 200 fixing C. I. steps and fixing manhole frame and covers (But excluding supply of manhole frame and covers) over manholes and house connection chambers and fixing Manhole covers (but excluding supplying of manhole covers) over scraper manhole etc. complete, providing and fixing safety chain wherever necessary as per the stipulations in the type design complete as per latest CPHEEO manual. (excl. excavation). Manhole type "B" circular type having inside diameter of minimum 1500 mm and for depth from 1.5 M to 4.0 M (for 150 mm to 600 mm dia sewers) Manhole type "B" as above but upto 1.5 M depth. Extra depth beyond 1.5 M but upto 4.0 M depth for type "B" manhole above.

809

-

-

... More
Providing and constructing Sewer manholes, scraper manholes and unit house connection chamber, as per the type design in brickmasonry in C. M. 1:5 and inside and outside 20mm thick plastering in C. M. 1:3 necessary 100 mm coping with reinforcement in R.C.C. M 200 fixing C. I. steps and fixing manhole frame and covers (But excluding supply of manhole frame and covers) over manholes and house connection chambers and fixing Manhole covers (but excluding supplying of manhole covers) over scraper manhole etc. complete, providing and fixing safety chain wherever necessary as per the stipulations in the type design complete as per latest CPHEEO manual. (excl. excavation). Manhole type "C" circular type having inside diameter of minimum 1500 mm and for depth beyond 4.0 m to 6.0 m (for 150 mm to 1800 mm dia sewers) Manhole type "C" as above but upto 4.0 M depth.

69

-

-

... More
Providing and constructing Sewer manholes, scraper manholes and unit house connection chamber, as per the type design in brickmasonry in C. M. 1:5 and inside and outside 20mm thick plastering in C. M. 1:3 necessary 100 mm coping with reinforcement in R.C.C. M 200 fixing C. I. steps and fixing manhole frame and covers (But excluding supply of manhole frame and covers) over manholes and house connection chambers and fixing Manhole covers (but excluding supplying of manhole covers) over scraper manhole etc. complete, providing and fixing safety chain wherever necessary as per the stipulations in the type design complete as per latest CPHEEO manual. (excl. excavation). Manhole type "C" circular type having inside diameter of minimum 1500 mm and for depth beyond 4.0 m to 6.0 m (for 150 mm to 1800 mm dia sewers) Manhole type "C" as above but upto 4.0 M depth. Extra depth beyond 4.0 M and up to 6.0 M depth for type "C" Manhole above.

50.5

-

-

... More
Ventilating Column- Providing and erecting C. I. and MS ventilating columns 15 cms. dia. with C.I. ornamental cap and Min 6.00 Mtr. Height (Height may be varying as per site) base fixed firmly with necessary foundation with one coat of red lead oxide paint and one coat of any approved colour with 15 cms dia, 10 Mt. in length with 0.35mt*0.35mt* M100 Encasing, stoneware or R.C.C. pipe connection with M.H. including excavation and jointing as required etc. complete. as per drawing and as approved by Chief Technical Officer (CTO). For 6 Mtr. Height ( 6 Mt MS pipe).

16

-

-

... More
CI Manhole. Frame & Cover - Heavy duty-CI Manhole. Frame & Cover Manufacture, supply & Delivery at store or at site of work frame & cover (of minimum 155 kg each) suitable to drainage manhole and as per type specification in IS 1726:1991 For sewer manholes- Heavy duty Frame suitable for 50cm dia opening of MH

374

-

-

... More
CI Manhole. Frame & Cover - Heavy duty-CI Manhole. Frame & Cover Manufacture, supply & Delivery at store or at site of work frame & cover (of minimum 155 kg each) suitable to drainage manhole and as per type specification in IS 1726:1991 For sewer manholes- Heavy duty Cover suitable for 50 cm dia opening of MH

374

-

-

... More
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at site of work precast RCC M.200 Frame & cover suitable to drainage M.H. and as per type design & Drawing including cost of reinforcement M.S. Angles or Flat, curing mold work etc. Heavy duty: Frame suitable for 50cm opening of MH

939

-

-

... More
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at site of work precast RCC M.200 Frame & cover suitable to drainage M.H. and as per type design & Drawing including cost of reinforcement M.S. Angles or Flat, curing mold work etc. Heavy duty: Cover suitable for 50cm opening of MH

939

-

-

... More
Re-instatement of Asphalt Roads including clearing and grubbing road, earth work and erosion control work, providing, laying, spreading, compacting granular sub base and base coarse (Non Bituminous and Bituminous), providing and applying Bitumin concrete and surface coat, tack coat as directed by engineer in-charge.

47938.1

-

-

... More
Re-instatement of CC Roads including clearing and grubbing road, earth work and erosion control work, providing, laying, spreading, compacting granular sub base and base coarse (Non Bituminous and Bituminous).

4864.1

-

-

... More
Re-instatement of Platforms/ Brick masonry work/ other structures damaged during work including material, labor, etc. complete. (For property connections any structures damaged such as platforms, brick works, etc. shall be made good as re-instatement work with material, labor, etc. complete, for each property in terms of number of connections.)

8159

-

-

... More
Providing and supplying ISI Standard R.C.C. pipes (of Sulphate Resisting Cement) in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc.,complete.(IS - 458/ 1989) Note : One collar should be supplied with each full length plain ended RCC pipe, cost included in rates below. One rubber ring should be supplied with each full length socketed pipe, cost included in rates below Class NP3 Test Pressure 0.7 Kg/sq.cm. 150 mm dia. (as provision for road crossing locations for replacement of existing pipeline).

300

-

-

... More
Providing and supplying D. I. K-9 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). Rate for DI Pipe based on Wholesale Price Index of Pig Iron as 114.20 for the Month of February - 2019. For sewerage project, cement mortor lining shall be with sulphate resistant cement-400 mm dia, makes Electro Steel Castings, Electrotherm, Jindal, Kejriwal, Tata Metaliks or as approved by Chief Technical Officer (CTO). (as provision for road crossing locations for replacement of existing pipeline).

300

-

-

... More
Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per ISI code.Class NP2, NP3, NP4-For 0.0 m to 1.50 m depth 150 mm dia. (as provision for road crossing locations for replacement of existing pipeline).

300

-

-

... More
Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per ISI code.Class NP2, NP3, NP4-For 0.0 m to 1.50 m depth 300 mm dia. (Existing RCC NP 3 pipeline of 300 mm diameter will be utilised. Hence piping work is limited to only for Lowering and laying, as provision for road crossing locations for replacement of existing pipeline).

550

-

-

... More
Lowering, laying and jointing/ C. I. S & S Spun pipes suitable for Tyton joints/ Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. comp. (In all depths) 400 mm.

300

-

-

... More
PCC for Pipe below Nala Crossing-Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6 - hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (upto 10 ton)-For Anchor Blocks and Encasing to pipe below nala crossing.

129.2

-

-

... More
Providing and laying controlled cement concrete M.200 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete (upto 10 ton) For Anchor Blocks and Encasing For Pipe below nala crossing.

2122.5

-

-

... More
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete. (upto 10 ton)-For Anchor Blocks and Planking and Centering for Pipe below Nala Crossing.

1741.5

-

-

... More
Supplying, cutting, bending ,binding and placing in position steel as per plan and design and as per IS 2502 including cost of steel and binding wire for reservoirs/ structures only including lift of 6m height/ depth below GL for all diametersFor deformed TMT bars conforming to relevant IS Fe-500 grade for all the dimeters.

28.5

-

-

... More
Carting of excavated excess soil, Lime, Murrum at proper place with in municipal limit as per instruction given by engineer in-charge and can be measured where dumped within lead of 10 km (carriage of fine sand upto 10 ton)

611.5

-

-

... More
Drilling of 500 mm dia horizontal borehole for water/ sewer main pipeline below the railway track/ National Highway including all strata with required length and fixing of 400 mm dia casing pipe of minimum 6 mm thick with welding/ pushing etc., complete. Providing fixing various size pipe for 193.7mm/ 219.10mm/ 244.5mm dia sewer-main of GI/MS of minimum thickness of 6mm thick in the Railway/ Highway boundary as per the as per the instructions and regulations of Railway/ Highway Authority and under supervision of Railway/ Highway Authority including Providing, Supplying and fixing spacers at specified interval if required between casing pipe/ sewer-main ISSI make sluice valve of required size at both sides of Railway/ Highway boundary with construction of brick-edge pavement including CC encasing in C.C 1:3:6 in 10m length of Pipe at both sides including Providing and fixing of M.S/ Iron manhole frame with cover for valve chamber with locking arrangement etc, complete with all materials, labour fabrication, hydraulic testing of pipe and valves etc., complete for 45m length which includes horizontal pushing and with open excavation- MS Casing+ Pipeline Size 219.1 mm.

4

-

-

... More
Drilling of 600 mm dia horizontal borehole for water/ sewer main pipeline below the railway track/ National Highway including all strata with required length and fixing of 500 mm dia casing pipe of minimum 6 mm thick or IRS casing pipe with welding/ pushing etc., complete. Providing fixing various size pipe for 273.1mm/ 323.9 mm/355.6 mm dia sewer main of GI/ MS of minimum thickness of 6mm thick casing pipe in the Railway/ Highway boundary as per the a the instructions and regulations of Railway/ Highway Authority and under supervision of Railway/ Highway Authority Including Providing ,Supplying and fixing spacers at specified interval if required between casing pipe/ sewer-main ISSI make sluice valve of required size at both sides of Railway/ Highway boundary with construction of brick-edge pavement including CC encasing in C.C1:3:6 in 10m length of Pipe at both sides including, Providing and fixing of M.S/ Iron manhole frame with cover for valve chamber with locking arrangement etc., complete with all materials, labour fabrication, hydraulic testing of pipe and valves etc., complete for 45m length which includes horizontal pushing and with open excavation. MS Casing Pipe + Pipeline Size 273.1 mm.

2

-

-

... More
Drilling of 600 mm dia horizontal borehole for water/ sewer main pipeline below the railway track/ National Highway including all strata with required length and fixing of 500 mm dia casing pipe of minimum 6 mm thick or IRS casing pipe with welding/ pushing etc., complete. Providing fixing various size pipe for 273.1mm/ 323.9 mm/355.6 mm dia sewer main of GI/ MS of minimum thickness of 6mm thick casing pipe in the Railway/ Highway boundary as per the a the instructions and regulations of Railway/ Highway Authority and under supervision of Railway/ Highway Authority Including Providing ,Supplying and fixing spacers at specified interval if required between casing pipe/ sewer-main ISSI make sluice valve of required size at both sides of Railway/ Highway boundary with construction of brick-edge pavement including CC encasing in C.C 1:3:6 in 10m length of Pipe at both sides including Providing and fixing of M.S/ Iron manhole frame with cover for valve chamber with locking arrangement etc., complete with all materials, labour fabrication, hydraulic testing of pipe and valves etc., complete for 45m length which includes horizontal pushing and with open excavation. MS Casing+ Pipeline Size 323.9 mm.

1

-

-

... More
Drilling of 600 mm dia horizontal borehole for water/ sewer main pipeline below the railway track/ National Highway including all strata with required length and fixing of 500 mm dia casing pipe of minimum 6 mm thick or IRS casing pipe with welding/ pushing etc., complete. Providing fixing various size pipe for 273.1mm/ 323.9 mm/355.6 mm dia sewer main of GI/ MS of minimum thickness of 6mm thick casing pipe in the Railway/ Highway boundary as per the a the instructions and regulations of Railway/ Highway Authority and under supervision of Railway/ Highway Authority Including Providing ,Supplying and fixing spacers at specified interval if required between casing pipe/ sewer-main ISSI make sluice valve of required size at both sides of Railway/ Highway boundary with construction of brick-edge pavement including CC encasing in C.C 1:3:6 in 10m length of Pipe at both sides including, Providing and fixing of M.S/ Iron manhole frame with cover for valve chamber with locking arrangement etc., complete with all materials, labour fabrication, hydraulic testing of pipe and valves etc., complete for 45m length which includes horizontal pushing and with open excavation. MS Casing.+ Pipeline Size 355.6 mm.

1

-

-

... More
Providing and Supplying DWC HDPE pipes-Providing and supplying of class SN8 structured wall polyethelene piping system (Pipe with on-line/ off-line coupler and elasomeric sealing ring) with non smooth external annular corrugated and smooth internal surfaces (Double wall for non pressure underground sewerage & drainage application as per IS 16098 (P2) including all local and central taxes transportation, freight charges octroi,inspection charges loading unloading conveyance to the departmental stores etc., complete. (100 mm ID) Makes: Prince Pipes & Fittings Ltd., Rex Polyextrusion Pvt. Ltd., Kiran Infra Tech Pvt. Ltd. The Supreme Industries Ltd. or as approved by Chief Technical Officer (CTO).

41760

-

-

... More
Providing and Supplying DWC HDPE pipes-Providing and supplying of class SN8 structured wall polyethelene piping system (Pipe with on-line/ off-line coupler and elasomeric sealing ring) with non smooth external annular corrugated and smooth internal surfaces (Double wall for non pressure underground sewerage & drainage application as per IS 16098 (P2) including all local and central taxes transportation, freight charges octroi,inspection charges loading unloading conveyance to the departmental stores etc., complete (150 mm ID) Makes: Prince Pipes & Fittings Ltd., Rex Polyextrusion Pvt. Ltd., Kiran Infra Tech Pvt. Ltd. The Supreme Industries Ltd. or as approved by Chief Technical Officer (CTO).

12500

-

-

... More
Lowering, laying and jointing class SN8 structured wall (External annular corrugated & Smooth internal surface Polyethelene piping and fittings with the help of coupler (online/ off line) attached with one end of pipe sliding over the elastomeric seling rubber ring placed on the specified valley of the corrogation at the spigot end, lowering the same in to the trench laying on the loer bedding (constructed at bottom of trenches at prescribed gradient, depth and alignment testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc., complete as per drawing, specifications & detailed engineering, including carriage of pipes & fittings from site stacks to the place of laying etc., as per the direction of Engineer-in -Charge. 100mm.

41760

-

-

... More
Lowering, laying and jointing class SN8 structured wall (External annular corrugated & Smooth internal surface Polyethelene piping and fittings with the help of coupler (online/ off line) attached with one end of pipe sliding over the elastomeric seling rubber ring placed on the specified valley of the corrogation at the spigot end, lowering the same in to the trench laying on the loer bedding (constructed at bottom of trenches at prescribed gradient, depth and alignment testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc., complete as per drawing, specifications & detailed engineering, including carriage of pipes & fittings from site stacks to the place of laying etc., as per the direction of Engineer-in -Charge-150mm- Appartment units and G.F + above 3 units -.1250 Nos.

12500

-

-

... More
Providing and constructing rectangular brick masonry chamber for house service connections as per the type design in brick masonry in C.M 1:3 including M-100 in foundation M 150 in benching inside plastering in C.M 1:3 and outside plastering in C.M1:3,coping in M200, and fixing RCC precast manhole frame and covers but excluding cost of manhole and cover etc, complete, excluding excavation. (Size 0.6x0.6m). As per the type design.

13210

-

-

... More
RCC precast M.H. Frame & Cover - Heavy duty- RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at site of work precast RCC M.200 Frame & cover suitable to drainage M.H. and as per type design & Drawing including cost of reinforcement M.S. Angles or Flat, curing mold work etc.,-House connection Chamber Light duty.

13210

-

-

... More
RCC precast M.H. Frame & Cover - Heavy duty-RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at site of work precast RCC M.200 Frame & cover suitable to drainage M.H. and as per type design & Drawing including cost of reinforcement M.S.Angles or Flat, curing mold work etc.,-House connection chamber light duty.

13210

-

-

... More
Dismantling tiles of stone floors laid in mortar including stacking of serviceable materials and disposal of unserviceable materials with all lead and lift.

9702.4

-

-

... More
Demolition including stacking of serviceable materials and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work

904.9

-

-

... More
Providing and supplying in sandard length, ISI mark rigid unplasticized PVC Pipes suitable for potable water with ring fit joint including cost of rings as per the IS Specification no 4985/1988 including all local and central taxes transportation freight charges octroi, inspection charges loading unloading conveyance to the departmental stores including cost of jointing materials etc., completeNote-One coupler/ ring shall be provided with each full length pipe cost of which is included in the rate3% discounted rate to be considered for coupler jointed pipe Test pressure 4 kg/ sqcm -IS 12818/1989- 110 mm dia. Makes: Astral, Supreme, Prince, Dutron or as approved by Chief Technical Officer (CTO). (PVC pipeline shall be laid from House Service inspection chamber to Property side chamber for sewerage system which is about 37.6 km.)

37600

-

-

... More
Providing and supplying in sandard length, ISI mark rigid unplasticized PVC Pipes suitable for potable water with ring fit joint including cost of rings as per the IS Specification no 4985/1988 including all local and central taxes transportation freight charges octroi, inspection charges loading unloading conveyance to the departmental stores including cost of jointing materials etc., completeNote-One coupler/ ring shall be provided with each full length pipe cost of which is included in the rate3% discounted rate to be considered for coupler jointed pipe Test pressure 6 kg/sq cm. is 12231/198- 110 mm dia 8, Makes: Astral, Supreme, Prince, Dutron or as approved by Chief Technical Officer (CTO). (PVC pipeline shall be laid from House Service inspection chamber to Property side chamber for sewerage system which is about 5.2 km.)

5200

-

-

... More
Providing, jointing of PVC Pipe special, etc. complete.

1

-

-

... More
Lowering, laying and jointing lowering PVC/uPVC/cPVC pipes and specials of following class and diameter including cot of conveyance from stores to site of works including cost of labour,material, cement solvent and giving hydraulic testing as per ISI Code- 110 mm dia pipeline.

42800

-

-

... More
Providing and laying cement concrete 1:4:8 (1- Cement : 4- Coarse sand : 8- Graded Brick bats aggregate 40mm normal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (more than 10 ton)

1033.8

-

-

... More
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (C) Vertical surface such as walls (any thickness) partitions and the like including attached buttresses & string course & the like. (up to 10 ton)- For Bottom Slab.

37.1

-

-

... More
Centring -Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts.(1) Square Rectangular Polygonal in plan. (upto 10 ton)- For Walls.

3554.4

-

-

... More
Providing upto floor two level precast cement concrete jali or grill 1:2:4 mix (1- Cement : 2- coarse sand : 4- graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia. Mild steel wire including roughening,cleaning, fixing and finishing in cement mortar 1:3 and curing complete. (A) 50mm thick- For Top cover.

1348

-

-

... More
HYSD Steel-Providing H.Y.S.D. Bar reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level (upto 10 ton) Makes: SAIL/TISCON/ RINL/ /TATA/Jindal/ Laxmi or as approved by Chief Technical Officer (CTO). (Note: Reinforcement for buildings and wastewater treatment and Pump House units shall be HYSDCRS (Corrosion Resistant Steel) of Grade Fe 500.)

81991

-

-

... More
Providing and laying Marbo Grenite tiles 8 to 10 mm thick, 24'' x 24'' in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand) finishing with flush pointing in white cement. (upto 10 ton).

9671.7

-

-

... More
Providing 10mm thick cement plaster in single coat on brick/ concrete walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement: 4- sand)

9033.6

-

-

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each diposited layer by ramming and watering.

1794.8

-

-

... More
Pumping machinary - Providing, installing, commissioning of submercible pumpsets of CRI/ Kirloskar/ Crompton Greaves or as approved by Chief Technical Officer (CTO), of suitable HP to pump the sewerage fom collection chamber to the nearest manhole with all accessories, lead lift etc complete as directed by Engineer-In Charge (Inclusive of material, labour and specials required with all taxes etc) 1.5 HP. (For the properties which are at lower levels and gravity connection to sewers not possible, sump-pump arrangement shall be made by the contractor to the nearest manhole/ sewerage system. The power connection for the same shall be obtained from the concerned user’s electrical connection).

449

-

-

... More
Pumping machinary- Providing, installing, commissioning of submercible pumpsets of CRI/ Kirloskar/ Crompton Greaves or as approved by Chief Technical Officer (CTO), of suitable HP to pump the sewerage fom collection chamber to the nearest manhole with all accessories, lead lift etc complete as directed by Engineer-In Charge (Inclusive of material, labour and specials required with all taxes etc) 3 HP. (For the properties which are at lower levels and gravity connection to sewers not possible, sump-pump arrangement shall be made by the contractor to the nearest manhole/ sewerage system. The power connection for the same shall be obtained from the concerned user’s electrical connection).

674

-

-

... More
Pumping machinary- Providing, installing, commissioning of submercible pumpsets of CRI/ Kirloskar/ Crompton Greaves or as approved by Chief Technical Officer (CTO), of suitable HP to pump the sewerage fom collection chamber to the nearest manhole with all accessories, lead lift etc complete as directed by Engineer-In Charge (Inclusive of material, labour and specials required with all taxes etc) 5 HP.(For the properties which are at lower levels and gravity connection to sewers not possible, sump-pump arrangement shall be made by the contractor to the nearest manhole/ sewerage system. The power connection for the same shall be obtained from the concerned user’s electrical connection).

225

-

-

... More
Making Electrical Connection to the pumps and charging, commissioning, etc. complete.

1

-

-

... More
Sewer Cleaning Equipment: Supplying, testing and Commissioning Jetting cum suction machinery with rodding, desilting, sucking tank; inclusive of four wheeler vehicle TATA 1613/ Eicher 20.16 or as approved by Chief Technical Officer (CTO), make with suitable RPM Imported Italian make Triplex Plunger Pump of running on vehicle engine having flow rate of minimum 255 LPM and pressure minimum 140 bar with high pressure jetting hose of I.D. 25.4 mm and length 60 mt with MS tank of minimum 5 mm thickness having total tank capacity 9000 lit. Partitioned with fresh water of 5000 litre and sludge tank of 4000 litre. With suction unit inclusive of vacuum pump of minimum capacity 390 m3/hr having maximum vacuum pressure of 85 to 95% having maximum operating relative absolute pressure of 1.5 bar running on vehicle engine with tank suction hose 75mm dia and length 15 mt. etc. complete with hydraulic system, hose reel, PTO (power take off unit), control panel, valves, instruments, accessories etc with cost of vehicles, etc. complete conforming with tender specifications and IS:11387-1985 or its latest revision.

1

-

-

... More
Sewer Cleaning Equipment: Supplying, testing and Commissioning Jetting machinery with rodding, desilting, sucking tank; inclusive of Four wheeler of MAKE TATA 275/TATA ACE or Vehicle as approved by Chief Technical Officer (CTO), with suitable RPM Triplex Plunger Pump having minimum capacity 13 LPM and minimum pressure 200 Bar directly coupled with a separate 10 HP heavy duty, 4 stroke, air cooled diesel Engine, with water tank having capacity 500 lit. with jetting hose of 30 m length with ID 1/4", etc. complete with hose reel, spraying hose and gun, valves, instruments, accessories, with cost of vehicles etc. complete conforming with tender specifications.

2

-

-

... More
Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for reservoirs/structures only including lift up to 6 meter height or depth below G.L. for all diameters. High yield strength deformed (HYSD) bars Using Mild steel confirming to ISS 226 – 1962 or ISS 432 ( i ) or latest.

0.5

-

-

... More
Labour charges, for welding, joiniing placing and providing painting to the frame etc complete as directed by the Engineer-In-charge.

1

-

-

... More
Carting of excavated excess soil, Lime, Murrum at proper place with in municipal limit as per instruction given by engineer in-charge and can be measured where dumped within lead of 10 km.

161.9

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. Upto 1.50 mt depth. In hard murrum, boulders incl. macadam road.

122.1

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. 1.50 mt to 3 mt depth. In soft rock and/ or masonry in CM or L M or Lime Concrete.

222.5

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. 3.0 mt to 4.5 mt depth. In hard rock and/ or in C. C. 1:2:4 or RCC with blasting, breaking, chiselling, or by chiselling/ breaking only.

224.7

-

-

... More
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. 4.5 mt to 6 mt depth. In hard rock and/ or in C. C. 1:2:4 or RCC with blasting, breaking, chiselling, or by chiselling/ breaking only.

35.9

-

-

... More
Providing and casting in situ C.C. in grade M-15 (approx. corresp. to prop. 1:2:4) (proportions as per mix design or as per Table 9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing comp. up to 6 meter depth or height (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. comp. for structure for other than water retaining-(without form work).

27.1

-

-

... More
Masonry for well staining-Masonry for well staining in C.M. 1:6 above ground level and up to 1.5 mt depth below average G.L Manhole wall in Brick masonry-Using burnt brick of standard size- Manhole wall up to 1.5 depth.

24.9

-

-

... More
Masonry for well staining-Masonry for well staining in C.M. 1:6 above ground level and up to 1.5 mt depth below average G.LManhole wall in Brick masonry- Using burnt brick of standard size (incuding for additional depth of 1.5M or part there off beyond 1.5M depth -Manhole wall up to 1.5 to 3.0m depth.

41.3

-

-

... More
Masonry for well staining-Masonry for well staining in C.M. 1:6 above ground level and up to 1.5 mt depth below average G.L Manhole wall in Brick masonry-Using burnt brick of standard size (incuding for additional depth of 1.5M or part there off beyond 1.5M depth -Manhole wall up to 3.0 to 4.5m depth.

57.2

-

-

... More
Cement Plaster (20 mm thick) -A) Cement plaster 20 mm thick in C.M. 1:2 using water proofing compound of approved quality including finishing etc. complete.

938.7

-

-

... More
Providing CI Steps -All types and size.

266

-

-

... More
Fixing C. I. steps in masonry in C. M. 1:3 including necessary C.C. for jointing etc. complete during progress of the work.

72

-

-

... More
Providing and casting in situ C.C. in grade M-20 (proportions as per mix design or as per Table 9 of IS456 2000 in masses by weigh batching) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing comp. up to 6 meter depth or height (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. comp. for structure for other than water retaining. RCC Footing for foundation (witht form work), C.C.M20 without (W.P. Chemical)

6.3

-

-

... More
Providing and cast in situ C.C. in grade M30 (proportions of mix design by weigh batching) using granite, quartzite trap metal of size 12 mm to 20 mm and o r6 mm to 12 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing comp. up to 6 meter depth or height (excluding cost of reinforcement) with centering and shuttering/ deshuttering etc. comp. for structure up to height of 6m height/ depth Avg GL for water retaining structures Vertical wall - 9. With form work for wall up to GL.

23.7

-

-

... More
Providing and cast in situ C.C. in grade M30 (proportions of mix design by weigh batching ) using granite, quartzite trap metal of size 12 mm to 20 mm and o r6 mm to 12 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing comp. up to 6 meter depth or height (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. comp. for structure up to height of 6m height/ depth Avg GL for water retaining structuresVerticla wall - 8. With form work for walls above G.L.

42.7

-

-

... More
Providing and cast in situ C.C. in grade M30 (proportions of mix design by weigh batching ) using granite, quartzite trap metal of size 12 mm to 20 mm and o r6 mm to 12 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing comp. up to 6 meter depth or height (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. comp. for structure up to height of 6m height/ depth Avg GL for water retaining structuresVerticla wall -1 Flat bottom slab with shuttering (with deduction for pump installation area).

3.3

-

-

... More
Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for reservoirs/ structures only including lift up to 6 meter height or depth below G.L. for all diameters. CRS steel all diameter Fe 500grade confirming to relevant I.S.

5.6

-

-

... More
Pump House- Designing (aesthetically) and constructing R.C.C frame structure of pump room with positive suction/ Negative suction. Without Gantry structure (Upto 3.60 M). Note:- 1. Minimum 15 % opening for ventilation should be provided. 2. Pump room rolling shutter, door and windows of aluminium section and window grill of iron should be provided (Included in Cost). 3. Plinth level of Pump house should be min.1 meter above GL. 4.Cost does not include foundation for pumping machinery.

15.1

-

-

... More
Supply, Installation, Testing, Commissioning Manual coarse screen with bar sizing of 50mm wide x 10mm thick and having 20mm clear gap between screen bar of SS 304. Size 400mm width x 300mm SWD + 300 mm Free Board. Makes: HDO, Triveni, Parchure, Shivpad, Geo Miller, Shree Technoor or as approved by Chief Technical Officer (CTO).

4

-

-

... More
Supply, Installation, Testing, Commissioning Sluice gate. Cast Iron Wall Thimble Mounted Sluice Gate as per IS:13349 standard, manually operated within dicating arrangement, suitable for 1.00m seating as well as unseating type operating water head, 3.735m CL-PL distance, rising spindle, upward opening, flush bottom closure type arrangement, open top flat back frame gate. (Design Water Head- Class-I Type.) Makes: Jash, Makali Engineering Corporation, H Sarkar & Co Ltd., Yaswant Industrial works or as approved by Chief Technical Officer (CTO)., 400mm (W) x 450mm (H)

4

-

-

... More
Supply, Installation, Testing, Commissioning Manual coarse bar screen with bar sizing of 50mm wide x 10mm thick and having 20mm clear gap between screen bar of SS 304. Size 300mm width x 200mm SWD + 300 mm Free Board. Makes: HDO, Triveni, Parchure, Shivpad, Geo Miller, Shree Technoor or as approved by Chief Technical Officer (CTO).

2

-

-

... More
Supply, Installation, Testing, Commissioning of Manual coarse bar screen with bar sizing of 50mm wide x 10mm thick and having 20mm clear gap between screen bar of SS 304. Size 300mm width x 160mm SWD + 300 mm Free Board. Makes: HDO, Triveni, Parchure, Shivpad, Geo Miller, Shree Techno or as approved by Chief Technical Officer (CTO).

8

-

-

... More
Supply, Installation, Testing, Commissioning Sluice gate. Cast Iron Wall Thimble Mounted Sluice Gate as per IS:13349 standard, manually operated within dicating arrangement, suitable for 1.00m seating as well as unseating type operating water head, 3.735m CL-PL distance, rising spindle, upward opening, flush bottom closure type arrangement, open top flat back frame gate. (Design Water Head- Class-I Type.) Makes: Jash, Makali Engineering Corporation, H Sarkar & Co Ltd., Yaswant Industrial works o or as approved by Chief Technical Officer (CTO)., 300mm (W) x 350mm (H)

10

-

-

... More
Supply, Installation, Testing, Commissioning sewage submersible, Non clog type pump suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, 1500 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations (4) all supports, clamps, pipe fittings alongwith mechanical seal, bearing bush, strainer etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S.bearing, S.S shaft with sleeve, SS strainer & MS motor body. Makes: MBH pump, Pullen pump, Jasco, Lubi pumps, Aqua, Kirloskar, Mather+Platt, KSB or as approved by Chief Technical Officer (CTO).

30

-

-

... More
Reflux Valves: Supply, Installation, Testing, Commissioning of ISI mark CI D/F Reflux Valves as per IS:5312 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. Reflux valves PN 1.0 IS 5312 with ISI mark L,L& J of SV/ AV/ BFV/ RV: Lowering, laying and jointing in position following C. I./ D/F Reflux valves, Butterfly valves, Sluice valves and Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. Sluice valves, Butterfly Valves, Reflux Valves Make: Kirloskar Brothers Ltd., Durga Engineering, IVC, R&D Multiple, AVK, VAG, L&T (Audco), Fouress Engineering, or as approved by Chief Technical Officer (CTO). -PN1 IS 5312 with ISI mark-100mm dia

45

-

-

... More
Knife gate valves - Supply, Installation, Testing, Commissioning in position Double Flanged Knife gate valves of PN 1.0 pressure rating. Conforming to AWWA C520/ MSS SP 81 having Body with CI IS 210 Gr. FG 260, Seal retainer ring, Knife gate, Fasteners with SS A240 Gr.304, Spindle SS A276 410, inlet seal of EPDM, Gland of Carbon steel, Gland packing PTFE, Spindle nut Brass, Supporting bracket and handwheel of Carbon steel, flange drilling shall be as per IS:1538; including transportation and all taxes complete. Makes: Jash, Fouress, Vaas (Dezurick), Orbinox or as approved by Chief Technical Officer (CTO).-100mm dia

45

-

-

... More
DI Pipe K-9 D/F Supply, Installation, Testing, Commissioning D. I. K-9 grade pipes (total length 5 meter) for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS - 8329/ 2000). (For sewerage project cement mortor lining shall be with sulphate resistance cement.) Makes: Electro Steel Castings, Electrotherm, Jindal, Kejriwal, Tata Metaliks, or as approved by Chief Technical Officer (CTO). (DI pipe for DI DF Pipe manufacturing shall be as per approved make of DI Pipes only) Inner Dia 100mm

450

-

-

... More
L, L & J of DI/ CI Pipe (flanges Joint) Of flanged DI/ C.I. pipes of all classes/ specials etc. including cost of all jointing materials rubber packing, nut bolts, including lowering laying jointing labour hydraulic testing etc. complete. Makes: Electro Steel Castings, Electrotherm, Jindal, Kejriwal, Tata Metaliks, or as approved by Chief Technical Officer (CTO). (DI pipe for DI DF Pipe manufacturing shall be as per approved make of DI Pipes only) Inner Dia 100mm

300

-

-

... More
D.I. Specials: Supply, Installation, Testing, Commissioning of Ductile Iron Flange socket spigot bends, tees, reducers or any other specials as per BS-EN-545/1995 Class-A series K12 suitable for use with D.I. Pipes manufactured as per IS: 8329/ 1994delivery of specials is to be made to GWSSB store or site of works including all taxes, loading, unloading, carting, stacking, insurance, inspection charges, octroi etc. complete. Flange Ended & upto 300 mm Dia. Makes: Electro Steel Castings, Electrotherm, Jindal, Kejriwal, Tata Metaliks, or as approved by Chief Technical Officer (CTO). (DI pipe for DI DF Pipe manufacturing shall be as per approved make of DI Pipes only)- Inner Dia 100mm

3000

-

-

... More
Pressure & Vacuum Gauges with Accessories: Design, Supply, Installation, Testing, Commissioning of Bourdon Type Pressure Gauge, ±1% accuracy, Direct bottom 1/2" NPT (M) process connection, IP 67, Glycerine filled, SS304 Case with Bayonet Type Bezel, SS316 L Bourdon Tube, SS 316 Movement material, Aluminium dial with black graduation on white background, Micro Zero adjustable pointer, neoprene gasket, Blow out disc, shatter proof glass, SS tag plate etc. as per IS 3624. 100 mm Dial Size & 0 to 6 Kg/cm2 (Discharge + Common Header)

45

-

-

... More
Providing sewage submersible, Non clog type pump suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, 2900 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations (4) all supports, clamps, pipe fittings alongwith mechanical seal, bearing bush, strainer etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S.bearing, S.S shaft with sleeve, SS strainer & MS motor body.DSR ITEMS 40m3/hr at 26m head. Makes: MBH pump, Pullen pump, Jasco, Lubi pumps, Aqua, Kirloskar, Mather+Platt, KSB or as approved by Chief Technical Officer (CTO).

2

-

-

... More
DI Pipe K-9 D/F: Supply, Installation, Testing, Commissioning D. I. K-9 grade pipes (total length 5 meter) for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS - 8329/ 2000). (For sewerage project cement mortor lining shall be with sulphate resistance cement.) Makes: Electro Steel Castings, Electrotherm, Jindal, Kejriwal, Tata Metaliks, or as approved by Chief Technical Officer (CTO). (DI pipe for DI DF Pipe manufacturing shall be as per approved make of DI Pipes only): Inner Dia 100mm

19

-

-

... More
L, L & J of DI/ CI Pipe (flanges Joint) Of flanged joints to flanged DI/ C.I. pipes of all classes/ specials etc. including cost of all jointing materials rubber packing, nut bolts, including lowering laying jointing labour hydraulic testing etc. complete. Makes: Electro Steel Castings, Electrotherm, Jindal, Kejriwal, Tata Metaliks, or as approved by Chief Technical Officer (CTO). (DI pipe for DI DF Pipe manufacturing shall be as per approved make of DI Pipes only). Inner Dia 100mm

20

-

-

... More
D.I. Specials: Supply, Installation, Testing, Commissioning of Ductile Iron Flange socket spigot bends, tees, reducers or any other specials as per BS-EN-545/1995 Class-A series K12 suitable for use with D.I. Pipes manufactured as per IS: 8329/ 1994delivery of specials is to be made to GWSSB store or site of works including all taxes, loading, unloading, carting, stacking, insurance, inspection charges, octroi etc. complete. Flange Ended & upto 300 mm Dia. Makes: Electro Steel Castings, Electrotherm, Jindal, Kejriwal, Tata Metaliks, or as approved by Chief Technical Officer (CTO). (DI pipe for DI DF Pipe manufacturing shall be as per approved make of DI Pipes only)- Inner Dia 100mm

151

-

-

... More
Reflux Valves: Supply, Installation, Testing, Commissioning ISI mark CI D/F Reflux Valves as per IS:5312 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. Reflux valves PN 1.0 IS 5312 with ISI mark L,L& J of SV/ AV/ BFV/ RV: Lowering, laying and jointing in position following C. I./ D/F Reflux valves, Butterfly valves, Sluice valves and Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. Sluice valves, Butterfly Valves, Reflux Valves Makes: Kirloskar Brothers Ltd., Durga Engineering, IVC, R&D Multiple, AVK, VAG, L&T (Audco), Fouress Engineering, or as approved by Chief Technical Officer (CTO).-PN1 IS 5312 with ISI mark-100mm dia

3

-

-

... More
CHAIN PULLEY BLOCK- Supply, Installation, Testing, Commissioning Chain pulley block with triple gear arrangement, lifting hook, laod chain & hand chain & locking device etc. Makes: Hercules Mechanical works, Cranedge India Pvt Ltd, RMS Industries, Indef, Sealinkers Pvt Ltd, Morris, Safex, W H Brady or as approved by Chief Technical Officer (CTO)., 1 T - 6m lift

1

-

-

... More
Knife gate valves - Supply, Installation, Testing, Commissioning Double Flanged Knife gate valves of PN 1.0 pressure rating. Conforming to AWWA C520/ MSS SP 81 having Body with CI IS 210 Gr. FG 260, Seal retainer ring, Knife gate, Fasteners with SS A240 Gr.304, Spindle SS A276 410, inlet seal of EPDM, Gland of Carbon steel, Gland packing PTFE, Spindle nut Brass, Supporting bracket and handwheel of Carbon steel, flange drilling shall be as per IS:1538; including transportation and all taxes complete. Makes: Jash, Fouress, Vaas (Dezurick), Orbinox or as approved by Chief Technical Officer (CTO).- 100mm dia

3

-

-

... More
LT Cable- Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip/ round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps/ in existing cable trench/ cable trays/ conduit/ pipe sleeves at road crossing or floor as per site requirement) conforming to IS:7098 (Part-1) & IEC:60502 (Part-1). The makes of cable shall be like RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 4C x 16 sq mm A2XFY armoured AL Cable

50

-

-

... More
Providing & fitting heavy duty brass cable glands (nickel-plated) with washers & rubber ring conforming to IS, suitable for 3, 3½ & 4 core cables for following size of Cable. Double Compression Brass Cable Glands. The makes of cable gland shall be like Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 4C x 16 sq mm A2XFY armoured AL Cable

2

-

-

... More
LT Cable- Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip/ round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps/ in existing cable trench/ cable trays/ conduit/ pipe sleeves at road crossing or floor as per site requirement) conforming to IS:7098 (Part-1) & IEC:60502 (Part-1). The makes of cable shall be like RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 4C x 10 sq mm A2XFY armoured AL Cable

450

-

-

... More
Providing & fitting heavy duty brass cable glands (nickel-plated) with washers & rubber ring conforming to IS, suitable for 3, 3½ & 4 core cables for following size of Cable. Double Compression Brass Cable Glands. The makes of cable gland shall be like Comet, Dowells, Beaco or as approved by Chief Technical Officer (CTO). 4C x 10 sq mm A2XFY armoured AL Cable

30

-

-

... More
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth for laying of cable. below ground/ road surface for enclosing cable and back filling the same to make ground as per original. The makes of DWC Pipe shall be like Duraline, Rex or as approved by Chief Technical Officer (CTO). 50 MM OD

350

-

-

... More
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable (16 bricks per meter).

350

-

-

... More
Providing and fixing of galvanized mild steel tube (medium grade) 50 mm dia nominal core and Required for crossing of road as requirement on site

100

-

-

... More
Making trench in Hard Murrum/ Tar Road of suitable width of 90 cms or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground.

100

-

-

... More
Starter Panel for SPS- Supplying & erecting approved make 3 phase motor control cubical panel (Star - Delta) made from16 G. CRCA sheet duly painted with epoxy powder painted inside and outside with hinged doors and locking arrangement, consisting of suitable size of ON- OFF isolator (AC - 3/23 duty) main fuses, single phasing preventer cum water level. Guard (Complete unit), Toggle switch to by pass Single phase preventer cum WLG, indicating lamps for R- Y- B phases, over load relay, Automatic water level controller, Ammeter & Voltmeter each with two way selector switch incoming wires duly socket Crimped, Panel to be erected on angle iron frame grouted on wall as directed. Star Delta & main contactor, overload relay, thermal/ Electronic Star delta cutoff timer, start - stop push buttons. The isolator overload relay & contactors of L& T, Siemens or Cuttler Hamer make only. Panel to be erected on angle iron frame ground on wall. The makes of Switchgear shall be like Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO). (b) S/D up to 10 H.P.

1

-

-

... More
LT Power Distribution Board for SPS: Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board having IP-54 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire/ copper-aluminium strips, rubber grommets, rib, bakelite control fuses for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. The standard companies switch gear shall be used and only manufacturers at CPRI approved factory and shall be certified by that company whose switch gears are used after fabrication for beneficial use. Cupboard with dimension 0.5m (L) x 1.2m (H) x 0.35 (D) Incoming- 63 A, FP MCCB with S/C and E/F Protection (Cat-III) -1 No One set of R,Y,B Phase indicating lamps with control MCB’s. Bus Bars-100A, 10kA TPN aluminium bus bars with coloured heat shrinkable insulation sleeve. Outgoing- 1. 32 A, FP MCCB with S/C and E/F Protection (Cat-III) for Star-Delta Starter of 10 HP Motor -2 Nos 2. 16A, FP MCB - 2 Nos & 10% spare to be considered with considerable rating feeders being available. The makes of Switchgear shall be like Siemens, ABB, Schneider Electric, L&T or as as approved by Chief Technical Officer (CTO).

1

-

-

... More
LT Power Distribution Board cum Starter Panel : Providing & erecting weather proof, dust & vermin proof, structural support mounted front operated outdoor type cubical panel board having IP-55 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire/ copper-aluminium strips, rubber grommets, rib, bakelite control fuses for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. The standard companies switch gear shall be used and only manufacturers at CPRI approved factory and shall be certified by that company whose switch gears are used after fabrication for beneficial use. The Panel shall have provision for 3-Ph Tariff Metering Arrangement. The Panel shall consisting of DOL Starter for control of motor as described below. Cupboard with dimension 0.5m (L) x 1.2m (H) x 0.35 (D). Incoming- 32 A, FP MCCB with S/C and E/F Protection (Cat-III) -1 No, One set of R,Y,B Phase indicating lamps with control MCB’s. Bus Bars- 63A, 10kA TPN aluminium bus bars with coloured heat shrinkable insulation sleeve. Outgoing- 1. 16 A, FP MCB (Cat-III) for DOL Starter of 0-5 HP Motor -1 Nos 2. 16A, FP MCB - 1 Nos & 10% spare to be considered with considerable rating feeders being available Starter- Providing approved make motor control cubical panel (Direct - on - line) made from 16 G. CRCA sheet duly epoxy powder painted inside and outside with hinged doors and locking, arrangement consisting of suitable size of ON- OFF isolator (AC - 3/23duty) main fuses, single phasing preventer, indicating lamps for R- Y - B phases, overload relay, Automatic water level controller, Ammeter, Voltmeter each with two way selector switch incoming, wires duly socket crimped, main contactor & overload relay, start - stop push buttons, to be erected on angle iron frame grouted on wall as directed. The isolator, overload relay & contactors will be of L & T, Siemens or BCH make only. (a) DOL up to 5.0 H.P. (The Control Circuit of Starter shall have provision for connecting NC (Normally Closed) Contact in series from outside instrument). The makes of Switchgear shall be Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO).

15

-

-

... More
Providing, erecting, fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete.

160

-

-

... More
Fabricating the box type items made from M.S. Sheet with A.I. supports, wings, doors, handles other hardware materials as per requirement design with finishing by three tank powder coating processed inside and outside painted, erected as directed including minor civil work.

96

-

-

... More
Supplying, erection & laying of Hot Dip Galvanized Iron strip wire 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.

6

-

-

... More
Supply, erection and Laying of of Hot Dip Galvanized Iron strip 25X6mm GI strip at a deth of 0.5m below ground as strip earth electrode, including termination/ interconnecting with GI Nut/Bolts, washer, Spring washer etc. as required. Jointing shall be done by overlapping & with two sets of Nut/ bolts and spring washer spaced at 50mm apart for earthing of the panels.

47.6

-

-

... More
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I. Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. For Electrical Installation covering Power Distribution Board, Starter Panels. etc. i.e. independent Earthing in normal soil. Length of Pipe: 3.00 mtrs Back filling Compound: 2 nos Bags of 25 Kg.

19

-

-

... More
Point wiring for Light/ Fan/ Bell/ Primary Point with 2-1.5 sq. mm & earthwire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in /flushed on wall/ceiling , complete with 6A Tissino Type ISI marked flush type switch/ bell push and accessories erected on Metal/ PVC Box covered with 3 mm thick PC(Polycarbonet)/ Acrylic sheet with necessary Lamp holder/ ceiling rose/ H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories. The makes of wire shall be like RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO).

3

-

-

... More
Providing following type of Modular type accessories mounted with PVC/ metallic box, single mounting base frame covered with textured/ metallic front plate, modules erected with necessary connection as desired by Engineer In charge. The makes of Modular switches shall be like Legrand, Crabtree, Clipsal, Anchor, MK or as approved by Chief Technical Officer (CTO). (A) One No. SP 6 Amp. Cat.II

1

-

-

... More
Providing following type of Modular type accessories mounted with PVC/ metallic box, single mounting base frame covered with textured/ metallic front plate, modules erected with necessary connection as desired by Engineer In charge. The makes of Modular switches shall be like Legrand, Crabtree, Clipsal, Anchor, MK or as approved by Chief Technical Officer (CTO).. (I) 16 Amp. SP one way switch. Cat.II

1

-

-

... More
Power & Receptacle DB: Providing and erecting Sheet Steel powder coated MCB distribution board - flush/ surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used). (But without MCB/RCCB/Isolator) - Single Way 4way, SS, Double door The makes of Switchgear shall be like Siemens, ABB, Schneider Electric, L&T, Legrand or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity; (a) 6 to 32 Amp.( Cat.III) The makes of Switchgear shall be like Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity; (a) 6 to 32 Amp. (Cat. III) The makes of Switchgear shall be like Siemens, ABB, Schneider Electric, L&T or as approved by Chief Technical Officer (CTO).

4

-

-

... More
Supply, laying, testing & commissioning of 1.1 kV grade, XLPE insulated, stranded Copper conductor, galvanised steel flat strip/ round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps/ in existing cable trench/ cable trays/ conduit/ pipe sleeves at road crossing or floor as per site requirement) conforming to IS:7098 (Part-1) & IEC:60502 (Part-1) of following sizes. The makes of wire shall be RR Cable, Polycab, RPG, Universal, Finolex or as approved by Chief Technical Officer (CTO). 4C x 2.5 Sq.mm. 2XFY CU Cable.

30

-

-

... More
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA polyester powder coated and high U.V. & corrosion resistance with diffuser and/or Polycarbonate optics with company mark/name, 120 to 300 V,Power Factor more than 0.9, THD 10 %, CCT 4000 K to 6500K, Uniformity ratio 0.7, Luminaire efficacy 85 lumens/watt, LED driver efficiency 85 %. CREE/ OSRAM/ PHILIPS Lumileds/ NICHIA/ SEOUL/Bridgelux(U.S.A.) make LED used for luminaire. (Each fitting required LM-79 & LM-80 Certificates) (A) Tube Light with integral/ non-integral driver (e) 36 Watts, Surge-4 KV, IP-20, 4 feet Cat-III The makes of Lighting fixtures shall be Wipro, Philips, Crompton Greaves, Bajaj ,Havel or as approved by Chief Technical Officer (CTO).

3

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware -Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware -Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories- Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable-Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories - Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories- Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). -Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2-Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories- Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system..Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories- Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable,Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories- Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable.Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable,Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable -Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system.Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). -Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software-Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). -Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware -Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable -Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable-Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories, Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software-Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable - Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software-Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO)..Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable - Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software-Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 500 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

6

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

6

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable - Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Panel accessories etc. Basic IO Count 32 Channel DI Card =6 32 Channel DO Card =4 8 Channel AI Card =4 8 Channel AO Card =4 8 Channel RTD Card =8 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL, Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software-Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable - Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). -Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software-Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable - Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). -Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software-Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable - Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software-Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software -Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO). Dia- 250 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO).-Range 0-25 kg/cm2

3

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured,XLPE Instrumentation Cable - Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Ultrasonic Level Transmitter at LS with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0- 10 M

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Transmitter at common delivery location with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Range 0-35 kg/cm2

1

-

-

... More
Supply, Installation, Testing, Commissioning of Full bore type Electromagnetic Flow meter at common delivery header with all necessary hardware and software Approved Make: ABB, Forbes Marshall, Siemens or as approved by Chief Technical Officer (CTO).-Dia- 100 mm

1

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Gauge with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). -Range 0-25 kg/cm2

2

-

-

... More
Supply, Installation, Testing, Commissioning of Pressure Switch with all necessary hardware Approved Make: ABB, H Guru, Waree or as approved by Chief Technical Officer (CTO). -Range 0-25 kg/cm2

2

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of Single PairX 1 Sqmm. Stranded Cu, Shelded, Armoured, XLPE Instrumentation Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

60

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 2.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

50

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of RS-485 Communication Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

10

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing of 50 X 50, GI Perforated, with Cover Cable Tray

40

-

-

... More
Supply, Laying-Fixing-Jointing of 3 Mtr Long Cu Electrode for Electronoc Earthing

1

-

-

... More
SITC of Non Redundant, 32 Bit Processor PLC Panel with 10" HMI, Ethernet Switch cum GSM/GPRS Modem, Panel accessories etc. Basic IO Count 32 Channel DI Card =3 32 Channel DO Card =2 8 Channel AI Card =2 8 Channel AO Card =2 8 Channel RTD Card =4 Modbus Node=4 Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO). ** Min. qty of cards is given in BoQ. Quantity of Cards will be as per requirement mentioned in Techchnical Specification and to be provided as per the requirement.

1

-

-

... More
Supply, Laying-Fixing-Jointing and Tampring of Communication Cable and Communication Accessories-Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

1

-

-

... More
SITC of UPS System for Pumping Station UPS3 KVA min. with one hour backup (Lead-Acid batteries), 230 V AC O/P, and any other items required to complete the system. Approved Make:HiREL,Emerson, Liebart or as approved by Chief Technical Officer (CTO).

1

-

-

... More
Supply, Installation, Testing, Commissioning of Conductivity type Level Switch with all accessories Approved Make: Sapcon,Levcon,Reliable or as approved by Chief Technical Officer (CTO). -Range 0- 5 M

15

-

-

... More
Cables & Cabling Accessories-Supply, Laying-Fixing-Jointing and Tampring of 3C x 1.5 Sqmm. Stranded Cu, Armoured Control Cable Approved Make:Polycab, Finolex, Delton or as approved by Chief Technical Officer (CTO).

1500

-

-

... More
SITC of Basic Micro PLC based Controller Unit for Pump Operation with Inbuilt Mon 8 Ch DI & 4 Ch. DO with all necessary accessories Approved Make:Schneider, ABB, Siemens or as approved by Chief Technical Officer (CTO).

15

-

-

... More
Integration works for SCADA at Existing 13 MLD STP and Communication with ICCC. Integration works of Existing DG Sets to PLC Systems at 13 SPS locations and Communicate with Central SCADA and ICCC with all necessary Hardware & Software complete.

1

-

-

... More
2X10 Kg/ hr Chlorination system and leak absorption system for 13 MLD STP - Implementation and supervision charges etc. complete.

1

-

-

... More
Energy Audit before Start of Works- Cost towards Data Collection, Survey and Investigation & Measurements including equipment hiring/ purchase, labour charges, Key professional charges and submission of IGEA report as specified in Technical Specification. 1. To identify various public installations, assets and equipment of STPs, Sewage Pumping Stations (SPS) and all other energy consuming assets within project area. 1. Data collection, Observation and assessment of current level operation and practices as specified in technical specification. 2.Energy consumption by type of energy, by department, by major items of process equipment, by end-use as specified in technical specification. 3. Energy cost and tariff data. 4. Pump and Motor condition assessment, Insulation and Lighting survey with portable instruments for collection and measurement data as specified in tec hnical specification. 5. Fee of Key Personnel for carrying out Energy Audit and implementation of improvement measures under the specified scope and defined battery limits -Energy Auditer, Electrical Engineer, Mechanical engineer. 6. Preparation of Detailed IGEA Report as specified in technical specification and scope of works.

1

-

-

... More
Energy Audit after Execution of Works- Cost towards Data Collection, Survey and Investigation & Measurements including equipment hiring/ purchase, labour charges, Key professional charges and submission of IGEA report as specified in Technical Specification. 1. To identify various public installations, assets and equipment of STPs, Sewage Pumping Stations (SPS) and all other energy consuming assets within project area. 1. Data collection, Observation and assessment of current level operation and practices as specified in technical specification. 2.Energy consumption by type of energy, by department, by major items of process equipment, by end-use as specified in technical specification. 3. Energy cost and tariff data. 4. Pump and Motor condition assessment, Insulation and Lighting survey with portable instruments for collection and measurement data as specified in technical specification. 5. Fee of Key Personnel for carrying out Energy Audit and implementation of improvement measures under the specified scope and defined battery limits -Energy Auditer, Electrical Engineer, Mechanical engineer. 6. Preparation of Detailed IGEA Report as specified in technical specification and scope of works.

1

-

-

... More
Operation & Maintenance of all types of Electrical, Mechanical equipment, machinery, Intruments for Sewerage System, including pipe line network, manholes, chambers, valves, rising mains, pumping stations STP and SCADA. The O&M work will consist of operation and maintenanc will also include , record keeping, measuring devices. Civil work's maintenance of SPSs, STP. The firm has to operate the pumps as per the stipulations mentioned in the Contract and as per the instructions of the Silvassa Municipality. The firm has to repair or replace pumps, motors, valves & pipes (all diameters), screen, gate, gantry, electrical items including day to day maintenance as well as preventive maintenance as required. The work also includes repair and maintenance of RCC/ DWC/ HDPE/ PVC transmission pipeline, rising mains and RCC NP2 & NP3 network including service connections and chambers. Work also includes day to day maintenance as well as periodical preventive maintenance of all kind of valves, mechanical equipment, instruments related to operation of SCADA and maintenance of gardening, plantation, road at the STP Campus. Maintain and record quality parameters of treated sewage and sludge disposal.excluding electricity bill for Pumping Stations & STP. The staff deployment rquired for O&M shall be done as per the Contract Agreement. The broad components include, Manpower requirement, office maintainance, expenses towards jetting machine trips,chemicals requirement, diesel reqirement and misc. items including all routine and preventive maintenance etc., Colour banding and suitably labelling with the stream designation and direction of flow for pipes to enable individual lines to be identified throughout their run, complete. Chemicals: Chlorine (39 kg/ day), Dewatering Polymer (3.98 kg/day), Lab Consumables (for daily quality monitoring), Lab Consumables (for daily quality monitoring), Minimum Labour Requirement, Plant Engineer/ Project Manager (Civil Engineer) - 1 No. for Monitoring the plant operation, Chemist (B.Sc. Chemistry)- 1 No. for Testing of parameters, Mechanic/ Fitter (ITI)- 1 No. for Maintenance of Mech. Equipment, Electrician (ITI)- 1 No. for Maintenance of Electrical supply and Equipment, Plant Operator (ITI)- 3 Nos. for Plant operation in shifts, Accountant cum Office manager (B. Com.)- 1 No. for Carrying out billing and expenses, Office Attendant cum Sweeper (HSC)- 1 No. for Cleaning and maintenance of Office, Gardener cum Sweeper- 1 No. for Cleaning and maintenance of Office Premise, Chowkidar- 3 Nos. for Security in shifts, Drivers for Office Vehicles (DL with HSC)- 1 No. for Driving, Manager/ Operation Engineer (Min 5 Year Exp. BE IC/EC/ELEC/IT)- 1 No. for Monitoring & System operation for SPS and STP, Supervisor at Command & Control Station Station (Diploma Holder)- 3 Nos. for Supervise the SPS and STP, Technician at Command & Control Station Station (Diploma Holder)- 1 No. for Replacement of non-performing units/ equipment, Mechanic/ Fitter (ITI)- 1 No. for Maintenance of Pumps and Motors, Helper (HSC)- 4 Nos. for Assistant to Fitter, Electrician (ITI)- 1 No. for Maintenance of Electrical supply and Equipment, Lift Manhole Pump operators- 3 Nos. for Operation of Lift Manhole Pumps, Drivers for Inspection Vehicles (HSC, DL for HV)- 3 Nos. for Driving & Operating Jetting Machines, Skilled Labor- 3 Nos. for Machine operation, Unskilled Labor- 3 Nos. for Assistance in Jetting activities, Network Engineer (Civil Engineer, 5 yrs exp in sewer pipelines)- 1 No. for Monitoring and addressing networks for overflows, damages, etc, Junior Network Engineer (Diploma Civil)- 2 Nos. for Routine inspection/ maintenance of network and pumping mains, Plumber (Pipeline, ITI)- 3 Nos. for Property Connections, Line replacement/ jointing, Skilled Labor- 3 Nos. for Assistance to Plumber for pipe/ masonry works, Unskilled Labor- 8 Nos. for Assistance to Plumber for making materials, Rate shall be quoted based on the above mentioned manpoer establishment, chemicals for O&M part of entire sewerage system for 10 years, EXISTING SYSTEM: Total O&M Cost for the 1st Year Note: In addition to above Contractor shall Operate & Maintain newly installed system / completed works during 1 st Year of construction period.

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 2nd Year Note: In addition to above Contractor shall Operate & Maintain newly installed system / completed works during 1st & 2nd Year of construction period.

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 3rd Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 4th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 5th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 6th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 7th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 8th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 9th Year

1

-

-

... More
EXISTING SYSTEM: Total O&M Cost for 10th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 3rd Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 4th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 5th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 6th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 7th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 8th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 9th Year

1

-

-

... More
NEWLY INSTALLED SYSTEM AFTER CONSTRUCTION, COMMISSION, TRIAL RUN: Total O&M Cost for 10th Year

1

-

-

... More
Energy Audit: Cost towards Data Collection, Survey and Investigation & Measurements including equipment hiring/ purchase, labour charges, Key professional charges and submission of IGEA report as specified in Technical Specification. To identify various public installations, assets and equipment of STPs, Sewage Pumping Stations (SPS) and all other energy consuming assets within project area. 1. Data collection, Observation and assessment of current level operation and practices as specified in technical specification. 2.Energy consumption by type of energy, by department, by major items of process equipment, by end-use as specified in technical specification. 3. Energy cost and tariff data. 4. Pump and Motor condition assessment, Insulation and Lighting survey with portable instruments for collection and measurement data as specified in technical specification. 5. Fee of Key Personnel for carrying out Energy Audit and implementation of improvement measures under the specified scope and defined battery limits -Energy Auditer, Electrical Engineer, Mechanical engineer. 6. Preparation of Detailed IGEA Report as specified in technical specification and scope of works. Energy Audit after 3 Years

1

-

-

... More
Energy Audit after 6 Years

1

-

-

... More
Energy Audit after 9 Years

1

-

-

... More
Survey, Investgation, Inpestion & Testing of Required Items, Neccessary Approvals, Detail Design Engineering, GFC & As Built Drawings

-

-

-

... More
Road Project works- The contractor Shall carryout all necessary Site Surveys, Geotechnical Investigations, Underground Utility Survey,Schedule of work and Shall Prepare Detailed Design, submit General Arrangement Drawings and Good for Construction (GFC) Drawings for Roads Works, Architectural and Visual Improvement, Bus shelters, Storm Water Drains, Tapping arrangements Works (Water, Sewer, OFC & Gas), OFC conduits, Utility Shifting’s (Water supply pipeline & appurtenances and Electrical Works), Cross Drainage works, Retaining wall & Electrical works and Obtaining all required approvals and clearances from client prior to execution. Water supply project Works- The contractor shall carryout all necessary site surveys, investigations, including existing underground utilities, Schedule of work and shall prepare Detailed Design of 24 x 7 water supply, Hydraulic Modelling of the network, Network Layouts, Prepare Pipeline Schedule, specification of Pumps, Valves, Valve Chamber, House Connections, Electromagnetic Water Meter, etc. The contractor shall also prepare General Arrangement Drawings, Good for Construction (GFC) Drawings for Water Supply system, with all allied works, refurbishment of pumping stations, intake well, WTP’s, with Civil, Electrical, Mechanical, Instrumentation works and including Obtaining all required approvals and clearances from client prior to execution. Sewerage Project Works- The contractor shall carryout all necessary site surveys, investigations, including existing underground utilities, schedule of work and shall prepare Detailed Design of Sewerage System with Hydraulic Modelling, Layouts, Prepare Pipeline Schedule, specification of Pumps, Valves, Screens, Valve Chambers, Lift Manholes, etc. The contractor shall also prepare General Arrangement Drawings, Good for Construction (GFC) Drawings for Sewerage System, with all allied works, with Civil, Electrical, Mechanical, Instrumentation works and Obtaining all required approvals and clearances from client prior to execution.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.