UT Administration Of Dadra And Nagar Haveli Tender
View complete overview of Dadra & Nagar Haveli UT Administration Of Dadra And Nagar Haveli Tender
UT Administration Of Dadra And Nagar Haveli Tender
Civil And Construction
Building Construction
Eprocure
Opening Date13 Sep 2024
Closing DateCancelled
Tender Amount₹ 1,97,72,939
Costs
EMD
₹ 3,98,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UTDNH_7235_1Tender No
E-TENDER NOTICE NO. 22 OF 2024-25 (BLDG)Tender Authority
UT Administration Of Dadra And Nagar Haveli ViewPurchaser Address
-Website
http://dnhtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Air Moving Equipment
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 1600 CFM Fresh Air Cabinet type fan. Complete in all respect including all required for the same.
1
-
-
Air Moving Equipment
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 4400 CFM Ex Air Cabinet type fan. Complete in all respect including all required for the same.
1
-
-
Air Moving Equipment
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 7900 CFM Ex Cabinet type fan. Complete in all respect including all required for the same.
2
-
-
Air Moving Equipment
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 3600 CFM Fresh Air Cabinet type fan. Complete in all respect including all required for the same.
1
-
-
Air Moving Equipment
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 6300 CFM Fresh Air Cabinet type fan. Complete in all respect including all required for the same.
2
-
-
Air Moving Equipment
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 4500 CFM Fresh Air Cabinet type fan. Complete in all respect including all required for the same.
1
-
-
Air Moving Equipment
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 5600CFM Ex Air Cabinet type fan. Complete in all respect including all required for the same.
1
-
-
Air Moving Equipment
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 24000 CFM tube Axial Fan EX A Fan. Complete in all respect including all required for the same.
1
-
-
Supplying & fixing of powder coated extruded aluminium Return Air Grills without aluminium volume control dampers as per specifications. Complete in all respect including all required for the same.
5.94
-
-
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. Complete in all respect including all required for the same.
16.2
-
-
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core. Complete in all respect including all required for the same.
16.2
-
-
Supply and Laying of 2 Core 1.5 Sqmm FRLS Flexible Cable (Red). Complete in all respect including all required for the same.
3500
-
-
Providing materia and Labour For fixing Steel Bearing Pivot in Door of Size - 125x25 mm approved make - Flora. Complete in all respect including all required for the same.
46
-
-
Providing material and labour for fixing Mortise shaft dead bolt (Alen key lock) of Approved Make - Kich. Complete in all respect including all required for the same.
32
-
-
Providing material and Labour For fixing SS 304 adjustable friction windows stays of size 355 X 19 mm of approved make with necessary stainless steel screws,
Size - 600 X 19 mm Make - Complete in all respect including all required for the same.
52
-
-
Providing material and Labour for fixing Anchor bolt of 20mm dia. J bolt 800 mm long with thread with nut and washer. Complete in all respect including all required for the same.
120
-
-
Providing material and Labour For fixing Gate Valve 100 mm dia of make - Zoloto - Article No. - 1006. Complete in all respect including all required for the same.
2
-
-
Providing material and Labour For fixing Brass NRV - 50 MM dia of make - Zoloto - Article No. 1009A. Complete in all respect including all required for the same.
2
-
-
Providing material and Labour For fixing Table Top Wash Basin of CERA Model CALBURT No. S2020137 Size: 550 x 400 x 140 mm in all respect including and as per direction of EIC. Complete in all respect including all required for the same.
7
-
-
Providing material and Labour For fixing Table Top Wash Basin of CERA Model CALBURT MINI No. S2020155 Size: 440 x 440 x 135 mm in all respect including and as per direction of EIC. Complete in all respect including all required for the same.
2
-
-
Providing material and Labour For fixing Pillar Cock of Jaquar Model Catloge No OPP-15001PM in all respect including and as per direction of EIC. Complete in all respect including all required for the same.
7
-
-
Providing material and Labour For fixing Pillar Cock of Jaquar Model Catloge No VGP-81001 in all respect including and as per direction of EIC
2
-
-
Providing material and Labour For fixing Flush Cock Valve of Jaquar Model Catloge No OPP-15083KPM + ALD -081 and Flush Cock Kit - ALD - 081 in all respect including and as per direction of EIC
6
-
-
Providing material and Labour For fixing Sink Cock of Jaquar Model Catloge No LYR-38347S and in all respect including and as per direction of EIC. Complete in all respect including all required for the same.
8
-
-
Providing material and Labour For fixing Wall hung WC of CERA Model Carnival Rimless No S1043148 Size: 510 x 365 x 380 mm in all respect including Seat Cover, Reg bolt and as per direction of EIC. Complete in all respect including all required for the same.
6
-
-
Providing material and Labour For fixing Metropole of Jaquar Model Catloge No FLV-1095N in all respect including and as per direction of EIC. Complete in all respect including all required for the same.
6
-
-
Providing material and Labour For Waste Coupling of Jaguar Model ALD-079 in all respect including and as per direction of EIC. Complete in all respect including all required for the same.
9
-
-
Providing material and Labour For fixing Bottle Trap of Jaguar Model ALD-769 in all respect including and as per direction of EIC. Complete in all respect including all required for the same.
11
-
-
Supply, Laying, Testing and commissioning of armoured cable of 1100 v grade of copper conductor of following sizes in ready made trench or.
2.5 Sq.mm x 12c CU. Cable. Complete in all respect including all required for the same.
200
-
-
Supply, Installation, Testing & commissioning of external type compound wall LED type light fixture complete with all respect with required driver & water tight junction box as per approval from architect & client. Complete in all respect including all required for the same.
160
-
-
Supplying, testing, comissioning of 7.5 meter overall street height light pole with 50 w light fixture. Complete in all respect including all required for the same.
20
-
-
Supplying, testing, comissioning of 3.6 meter overall height post top light pole with 50 w light fixture. Complete in all respect including all required for the same.
10
-
-
Supply & Installation of PVC White Roller Blinds with Heavy aluminium channel and required accessories. Complete in all respect including all required for the same.
1626.21
-
-
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine
to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to
introduce steel bars for sunshades/balconies including fixing the steel bars in position using
epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all
complete as per direction of Engineer-In-Charge. Upto and including 12mm dia. Complete in all respect including all required for the same.
5333
-
-
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level Complete in all respect including all required for the same.
5480.55
-
-
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (B) Walls, from top of foundation level upto floor two level Complete in all respect including all required for the same.
51.3
-
-
20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete. Complete in all respect including all required for the same.
180
-
-
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials. Etc. complete. Complete in all respect including all required for the same.
180
-
-
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarsesand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick Complete in all respect including all required for the same.
162
-
-
Providing material and labour for fixing of expansion joint system for 100mm wide expamsion joint gap of approved make related with floor location as per drawings and direction of Engineer-In-Charge. The joints system shall be of materials that accommodates multi directional seismic movement without stress to it's components. Provision of 3 mm thick water Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design. Rate shall be inclusive of Polythene sheet, selaent filling, shalitex board for filler material in between the system as per drawing. Expansion joint system shall be as approved for Terrace level including arrangements for the same etc complete as directed by engineer in charge. Complete in all respect including all required for the same.
200
-
-
Providing and applying spray applied, 2-component Polyurea over concrete surface on thoroughly prepared and cleaned surface mechanically to remove all chipping and loose material and laitance by mechanical grinding, treatment of cracks and honeycombing by suitable repairing method as approved by Engineer-in-charge as per site condition. Then application of 2-component Polyurea that shall be quick/fast Setting, elastomeric waterproof, spray applie in two coat to acheiv eminimum 1.5mm DFT by high-pressure spray application, heated two component, spray proportioning equipment. The proportioning equipment must be capable of supplying correct pressure and heat for the appropriate hose length on a consistent basis. The Polyurea coating system must deliver the following properties: Solids by Volume shall be 100%, Tensile strength ASTM D412 10 MPa, Tear Resistance ASTMD624C shall be minimum 50N/mm, Shore A Hardness (ASTMD2240) not less than 80, Elongation ASTMD 412400%, crack bridging ability of crack bridging ability of minimum 2 mm as per ASTM C1305, and resistance to fire to std (EN 13501-1) Class E. Complete in all respect including all required for the same.
642
-
-
Providing and applying water repellant paint two coat coating on external texture plaster walls for any height with necessary scaffolding finishing surface etc. Including cleaning the surface, removing loose material etc. Complete as directed by Engineer In-charge. Complete in all respect including all required for the same. Complete in all respect including all required for the same.
16327.69
-
-
INR Zero Only
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements