UT Administration Of Dadra And Nagar Haveli Tender
View complete overview of Dadra & Nagar Haveli UT Administration Of Dadra And Nagar Haveli Tender
UT Administration Of Dadra And Nagar Haveli Tender
Civil And Construction
Building Construction
Eprocure
Opening Date30 Jan 2024
Closing Date7 Feb 2024
Tender Amount₹ 6,78,210
Costs
EMD
₹ 14,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UTDNH_6932_1Tender No
E-TENDER NOTICE NO. 49 OF 2023-24 (BLDG)Tender Authority
UT Administration Of Dadra And Nagar Haveli ViewPurchaser Address
-Website
http://dnhtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of Toilet Block for Food and Civil Supplies and Consumer affairs (Supply and Godown) at Masat
BOQ Items
... More
Providing material and labour for filling in plinth WITH UNSCREEN GRAVEL under floors including watering, ramming consolidating and dressing etc. complete.
6.6
-
-
... More
Providing material and labour for filling in foundation and plinth with RUBBLE under floors including filling gravel in gaps and consolidating deposited layers by ramming water etc. complete.
14.5
-
-
... More
Providing and laying cement concrete 1:3:6 (1- Cement : 3 Coarse sand : 6- crushed stone aggregates 20 mm nominal size) and curing complete including cost of formwork in (A) Wall Caps / Coping
15.3
-
-
... More
Providing and laying controlled cement concrete M.200 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete
5
-
-
... More
Providing and laying controlled cement concrete M.200 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in (B) COLUMNS:(i) Having cross-sectional area 0.05 to 0.08 Sq.M
1.75
-
-
... More
Providing and laying controlled cement concrete M.200 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in (A) BEAMS :(iii) Having cross-sectional area more than 0.05 Sq.M and upto 0.08 Sq.M
5
-
-
... More
Providing and laying controlled cement concrete M.200 and curing complete including the cost of formwork and excluding cost of reinforcement for reinforced concrete work in Lintels, Beams, Girders and Cantilever upto floor two level etc complete as directed by Engineer-in-charge.
0.9
-
-
... More
Providing and laying controlled cement concrete M.200 and curing complete including the cost of formwork and excluding cost of reinforcement for reinforced concrete work ( C ) Slabs, landing, shelves and Cantilever upto floor two level, etc complete as directed by Engineer-in-charge.
7.45
-
-
... More
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not xceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete. Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (A) Foundations, Footings, Bases of Colum ns etc. and Mass concrete
14.05
-
-
... More
Providing TMT Bar FE 415 reinforcement for R.C.C. work including ending, binding and placing in position complete upto floor two level
1740.1
-
-
... More
Providing material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional
8.05
-
-
... More
Providing material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in superstructure above floor two level in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B) Conventional
12.32
-
-
... More
Providing material and labour for (i) Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in foundation and plinth (B) Conventional
33.19
-
-
... More
Providing material and labour for 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (iii) Cement mortar 1:6 (1-cement:6-sand) for finishing with a floating coat of neat cement slurry.
194.05
-
-
... More
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and smooth in (iii) Cement mortar 1:6 (1-cement:6-sand)
57.5
-
-
... More
Providing and fixing FRP frame size 125x65 mm and 35mm thick FRP shutter having extra reinforcement on sides & edges in polish finish. The core of the shutter & frame is to be filed up with injected polyurethene foam done in situ alongwith embedded wooden pieces for stiffening & also taking hinges & fintures. The whole FRP frame & shutter is to be water proof weather proof, termite proof & resistance to mild acid/alkali. Rates are to be inclusive of S.S hinges with necessary screws & alluminium S.S fixtures & fastenings & fastener sleeve.
20.3
-
-
... More
Providing and laying white glazed tiles 6mm thick in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush pointing in white cement.
38.1
-
-
... More
Providing and laying Ceramic tiles 6mm thick in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush pointing in white cement.
118.6
-
-
... More
Distempeing (Two coats) with oil bound washable distemper of pproved brand and manufacture and of required shade on wall surfaces to give an even shade, over and including a priming coat with alkali resistance primer of approved brand after thoroughly brushing the surface and other foreign matter and also including preparing the surface even and sand parpered smooth. Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.
220
-
-
... More
Providing and fixing water closet squatting Pan (Indian type W.C. Pan) size 580mm (Earthwork, bed concrete, foot reste and trap to be measured and paid for separately) (A) Vitreous China.(I) Long pattern = White colour
2
-
-
... More
Providing and fixing wash down water closet (European type, W.C. Pan) with integral P or S trap including jointing the trap with soil pipe in Cement Mortar 1:1 (1-Cement : 1-fine sand) (Seal and cover to be measured and paid for separately)(A) vitreous China Pattern :(i) in white colour
2
-
-
... More
Providing and fixing 12.5 Litres high level C..I. flushing cistern with A pair of C.I. or Mild steel brackets, complete with fittings such as syplionic arrangement, 15mm nominal size brass ball valve with polythene float, lever G.I. China (60 cm. ) and pull union and couplings for connections with inlet, outlet and overflow pipes etc. including cutting holes in walls and making good the same (overflow pipe to be measured and paid fo separately )
2
-
-
... More
Providing and fixing wash basin with single hole for pillar tap with C.I. or M.S. brackets painted white including sutting holes and making good the same but excluding fittings.(A) Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white colour.
2
-
-
... More
Providing and fixing Urinal or approved quality including conecting the Urinal with waste pipe , tap etc. complete.(A) White earthenware flat back or corner type size 430mm x 260mmx350mm.
4
-
-
... More
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 75 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls.
4
-
-
... More
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with bricks having crushing strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i) Inside dimensions 455mmx 610mm and 450mm deep for single pipe line.
8
-
-
... More
(B) Providing sock pit of 5.00 Cu.M. Volume including excavating and filling brickbats with dry masonry work at top for 45cm. height including covering the top with stone including providing vatas in C.M. 1:3 with finishing curing etc.complete as directed.
1
-
-
... More
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(G)110 mm
12
-
-
... More
Providing material and labour for laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
40
-
-
... More
Providing and fixing brass screw down stop tap.(A) 15mm dia.
10
-
-
... More
Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (ii) 20mm dia.
7
-
-
... More
Providing and fixing Gun metal check or non-return fullway wheel valve.(C) 25mm dia.
4
-
-
... More
Providing erecting and fixing double coated ISI water tank of required capacity each with all necessary fittings and connection etc. complete on terrace
1000
-
-
... More
Providing and laying marble stone slab flooring over 20mm (average)base of cement mortar 1:6 (1-cement : 6 coarse sand) or L.M. 1:1.5(1- lime putty : 1.5 - coarse sand) laid and jointed with gray cement slurry including rubbing and polishing complete. (A) Marble slab 25mm thick
4
-
-
... More
Providing and Fixing Jet Spray Heavy Duty with S.S. Braised Hose 60cm Long Standard Design (Make Jaquar, Kohler, Roca, and/or as approved by Engineer-incharge Jet Spray Nozzle) conforming to IS:Standards complete with Jet Spray Nozzle With PVC Tube, Fixing Nut & Jet Flange, etc complete as directed by engineer-incharge.
2
-
-
... More
Providing and fixing C.P. brass angle stop cock heavy duty with cap for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore with all fittings, etc complete as directed by engineer-incharge.
2
-
-
... More
Providing and fixing C.P. brass waste for washbasin or sink. (A)
32mmdia.
6
-
-
... More
Providing and fixing G.I. inlet connection - 15mm dia
6
-
-
... More
Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at required spacings and frame alround, square or round bars with round headed bolts and nuts or by screws. (B) ORNAMENTAL GRILL
354
-
-
... More
Providing Material, Labour and equipments for Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thickjointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : including Khurra & Gola work
With average thickness of 120 mm and minimum thickness at khurra as 65 mm, etc complete as directed by engineer-incharge.
47.27
-
-
... More
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete Cat.III
16
-
-
... More
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (C) with oval conduit /PVC casing capping double lock type (b) 2 wire 2.5 sq. mm
23
-
-
... More
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) (b) sheet steel double door (i) 4 way
1
-
-
... More
Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat.III
1
-
-
... More
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity Cat.III
1
-
-
... More
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 120 to 300 V,Power Factor more than 0.9, THD 10 %, CCT 3000 K to 6500K, Luminaire efficacy 85 lumens/watt ,LED efficiency-110 lumens/watt
LED driver efficiency 85 % CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridgelux make LED used for luminaire. ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (A) Tube Light with integral driver (d) 22-24 Watts, Surge - 2KV,IP-20, 4 feet Cat.III
6
-
-
... More
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 120 to 300 V,Power Factor more than 0.9, THD 10 %, CCT 3000 K to 6500K, Luminaire efficacy 85 lumens/watt ,LED efficiency-110 lumens/watt LED driver efficiency 85 %
CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridgelux make LED used for luminaire. ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (B) LED Lamps integral type, with PC diffuser suitable LAMP holder (b) 5 to 8 watts Cat.III
6
-
-
... More
Supplying & erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame ABS body with inbuilt lowers & square frame.
4
-
-
... More
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved or embossed 120 to 300 V,Power Factor more than 0.95, THD 10 %, CCT 3000 K to 5700K,
Uniformity ratio 0.45, Luminaire efficacy 100 lumens/watt . LED driver efficiency 85 %.CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/ BridgeLux (U.S.A.) make LED used for luminaire. ( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and 10 kv non integral ,Light must have 440VAC line supply protection. It should withstand 48 hours for 440VAC line supply. (d) above 36 to 48 watts
1
-
-
... More
INR Zero Only
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements