Omnibus Industrial Development Corporation Limited Tender
View complete overview of Dadra & Nagar Haveli OIDC Tender
Omnibus Industrial Development Corporation Limited - OIDC Tender
Eprocure
Opening Date26 Jun 2019
Closing Date19 Jul 2019
Tender Amount₹ 56,62,171
Costs
EMD
₹ 1,13,243Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_DAMAN_377_1Bid Award Id
ViewTender No
OIDC/DNH/CD/2019/237Tender Authority
Omnibus Industrial Development Corporation Limited ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Design,Supply,Installation,Testing & Commissining of Panel for fire Pumps Control P saenael.l,For Fire Hydrant Pump Electric Panel For Auto System Jockey Pump and Main Pump Common Auto Control Panel suitable for Auto operation of above 2 electrical pumps having ASD starter for main pump. DOL starter forJockey Pumps having incoming MCCB, Bus bar, IndicatingLamps Push Buttons etc. With low level indicator. Make- L&T, ABB,Siemens and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
AUTOMATIC PRESSURE CONTROL PANEL FOR DIESEL PUMPS Witrh Battery hargesr Fabricating, supplying, installation, testing & commissioning of totally enclosed cubicle type diesel fire pump control panel free standing, floor mounted, comparatmentalised, sectionalised, dust ,dump and vermin proof with suitable natural ventilation arrangement,front and rear accessible,lockable power cum control panel, abricated from 1.6/2 mm thick MS sheet (to give IP 54 protection)Powder coated with pproved colour shade. Suitable to above capacity of Diesel Engine Driven Pump. Make- L&T, ABB,Siemens and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Pressure Switch: Info’s rT 100 Supply & Installation of Pressure Switch approved make & Ranhe 0-10 kg/cm2. Connection size25(*) NB & SS 304 casing, Pressure Switch out put Should be with interface such that fire water/ Diesel Driven Pump and jockey pump can start automatically at set pressures. Make-Danfoss, Switzer and as approved and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Supply & Installation of Pressure Gauges Burdon type pressure gauges With gauges cock male wares/ Febig 0-14 Rang SS hion dia gauge with siphon waree / Febig / H. Guru SS 4” Dall. Make- H Guru, Fiebig, Wika and as specified in tender document & approved and directed by Engineer-In-Charge.
4
-
-
CI Double Flanged Type Non Return Valve: Supply Installation testing & commissioning of NRV Valve Heavy duty with necessary, sutaible flanges, gaskets,nuts/bolts laboar work etc.150 mm Dia. Make- Danfoss, Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
2
-
-
CI Double Flanged Type Non Return Valve: Supply Installation testing & commissioning of NRV Valve Heavy duty with necessary, sutaible flanges, gaskets,nuts/bolts laboar work etc.100 mm Dia. Make- Danfoss, Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Supply Installation testing & commissioning of CI Sluice Valve – Non Rising Spindle Type with necessary, sutaible flanges,gaskets,nuts/bolts etc of 150 mm Dia. Make- Kirloskar, I.V.C., Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Supply Installation testing & commissioning of CI Sluice Valve – Non Rising Spindle Type with necessary, sutaible flanges,gaskets,nuts/bolts etc of 100 mm Dia. Make- Kirloskar, I.V.C., Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Supply Installation testing & commissioning of Safety Valve Gun Metal Safety Valve with necessary,sutaible flanges,gaskets,nuts/bolts etc. Make- Kirloskar, I.V.C., Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Supply Installation testing & commissioning Air Purge Valve Size : 25 MM Dia Air Release Valves Gun Metal piston lift type check to with screwed ends. Make- Kirloskar, I.V.C., Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
2
-
-
Supply,Installation testing & commissioning Gun Metal Ball Valves GSME rising Ball valve with handle as per specification PN: 1.6 rated.25 mm. Make- Danfoss, Castleand as specified in tender document & approved and directed by Engineer-In-Charge.
8
-
-
Supply,Installation testing & commissioning Gun Metal Ball Valves GSME rising Ball valve with handle as per specification PN: 1.6 rated.50 mm. Make- Danfoss, Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Supply, Installation, Testing & Commissioning of above ground GI Pipe, For Water system Complete with Class “C” Fitting like Elbow, Flange, Reducer, Nut & Bolts. Gasket, Fasteners etc, one coat of primers & 2 coats of enamel paint of Asian / Eq. male and fire Red cooler. . Dia-200 mm C Class. Make – Jindal,Tata and as specified in tender document & approved and directed by Engineer-In-Charge.
6
-
-
Supply, Installation, Testing & Commissioning of above ground GI Pipe, For Water system Complete with Class “C” Fitting like Elbow, Flange, Reducer, Nut & Bolts. Gasket, Fasteners etc, one coat of primers & 2 coats of enamel paint of Asian / Eq. male and fire Red cooler. Dia-150 mm C Class. Make – Jindal,Tata and as specified in tender document & approved and directed by Engineer-In-Charge.
132
-
-
Supply, Installation, Testing & Commissioning of above ground GI Pipe, For Water system Complete with Class “C” Fitting like Elbow, Flange, Reducer, Nut & Bolts. Gasket, Fasteners etc, one coat of primers & 2 coats of enamel paint of Asian / Eq. male and fire Red cooler. Dia-100 mm C Class. Make – Jindal,Tata and as specified in tender document & approved and directed by Engineer-In-Charge.
105
-
-
Supply, Installation, Testing & Commissioning of above ground GI Pipe, For Water system Complete with Class “C” Fitting like Elbow, Flange, Reducer, Nut & Bolts. Gasket, Fasteners etc, one coat of primers & 2 coats of enamel paint of Asian / Eq. male and fire Red cooler. Dia-80 mm C Class. Make – Jindal,Tata and as specified in tender document & approved and directed by Engineer-In-Charge.
12
-
-
Supply, Installation, Testing & Commissioning of above ground GI Pipe, For Water system Complete with Class “C” Fitting like Elbow, Flange, Reducer, Nut & Bolts. Gasket, Fasteners etc, one coat of primers & 2 coats of enamel paint of Asian / Eq. male and fire Red cooler. Dia-50 mm C Class. Make – Jindal,Tata and as specified in tender document & approved and directed by Engineer-In-Charge.
156
-
-
Supply, Installation, Testing & Commissioning of above ground GI Pipe, For Water system Complete with Class “C” Fitting like Elbow, Flange, Reducer, Nut & Bolts. Gasket, Fasteners etc, one coat of primers & 2 coats of enamel paint of Asian / Eq. male and fire Red cooler. Dia-40 mm C Class. Make – Jindal,Tata and as specified in tender document & approved and directed by Engineer-In-Charge.
144
-
-
Supply, Installation, Testing & Commissioning of above ground GI Pipe, For Water system Complete with Class “C” Fitting like Elbow, Flange, Reducer, Nut & Bolts. Gasket, Fasteners etc, one coat of primers & 2 coats of enamel paint of Asian / Eq. male and fire Red cooler. . Dia-25 mm C Class. Make – Jindal,Tata and as specified in tender document & approved and directed by Engineer-In-Charge.
156
-
-
Providing Under Ground Pipe Line With Anti Corrosive Treatment Wrapping & Coating work for underground pipe Supply Installation, testing & Commissioning of underground Piping for fire water system with Fitting, Fasteners, Gasket wire Brushing one coats of primer & application of 4 mm Pypecoat wrapping material Alongwith Test and as specified in tender document & approved and directed by Engineer-In-Charge..
36
-
-
Proiding and installing Butter Fly Valve with necessary, sutaible flanges, gaskets,nuts / bolts etc 100 mm Dia PN 1.6. Make- Danfoss, Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
6
-
-
Proiding and installing Priming tank 1000 Ltrs. With necessary G.I. Plumbing & Pipe fittings complete.Make as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Proiding and installing Foot valve with necessary, sutaible flanges, gaskets, nuts /bolts etc 150 mm dia. Make- Kirloskar, I.V.C., Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
2
-
-
Proiding and installing Foot valve with necessary, sutaible flanges, gaskets, nuts /bolts etc 100 mm dia. Make- Kirloskar, I.V.C., Castle and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Proiding and installing Stand Post M.S. Stand Post with 90 Deg. Bend & flange To fix hydrant. 80 mm dia.and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Proiding and installing Stand Post M.S. Stand Post with 90 Deg. Bend & flange To fix hydrant. 100 mm dia. and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Proiding and fixing Single Head Hydrant Valve 63 mm Dia ss SS Hydrant Valve Conforming IS 5290 complete with 80NB marching Flange, Downward Pattern ISI Mark and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Providing & fixing Hose Pipe With Instantaneous Coupling Type RRL Type Hose Of 63 mm dia 15 mtrs. Long Fire Hydrant Hose Pipes RRL Type-A as per IS: 636 Size 63 mm dia and 15mtr long with Nn-Controll Precolated, complete with Male-Female Instantaneous coupling and wire binding. Test Pressure 23kg/cm2, Working Pressure 14kg/cm2. Make- Eversafe, Newage and and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Providing & fixing MS Hose Box ( Single Door ) Ms Hose Box fabricated from 20 swg cold rolled sheet with 3 mm glass front window, painted with powder coated p.o.red out side & white inside. Make- Eversafe, Newage and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Providing and fixing Small Bore ¾ “ Dia Hose Reel Drum Set: MS Drum set with 30 mtrs. Rubber Hose GM Shutoff Nozzle Complete set. Make- Eversafe, Tiger, Kosmos and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Providing & fixing Branch – Pipe Fire Hydrant Short Branch Pipe Nozzle SS With ISI Mark and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Providing & fixing Inlet Valve Siamese Connection For Fire Brigade Inlet: 100 dia Tow way fire brigade connection with 63 mm dia instantaneous inlet complete with all necessary fittings and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Providing & fixing M.S. Bracket For Above Ground Pipe Lines Structural steel consisting of channel, beam, angle, rod, square tube, U clamps etc for MS support of pipe lines and as specified in tender document & approved and directed by Engineer-In-Charge.
800
-
-
Design,Supply,Installation and fixing of Pressure Vessel Assembly for Automation for Fire fighting system and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Supply and fixing Anchor Bolt wih Washer of appropriatte size for Fire fighting system and as specified in tender document & approved and directed by Engineer-In-Charge.
200
-
-
Supply,Installation,Testing & Commissioning of Fire Alarm System Micro Processor Based Conventional Type Supply Installation testing and commissioning of micro processor based/conventional type Fire Alarm panel As per IS 2189 modular construction withBattery back-up and built in Battery charging. Panel made of M.S. Sheet metal enclosure cabinet wall mounting type having 4 Zone. Make AGNI/Qutakand as approved and directed by Engineer-In-Charge.
1
-
-
Supply,Installation,Testing & Commissioning of Manual Call Point with Base and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Supply,Installation,Testing & Commissioning of Hooter with Base and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Supply,Installation,Testing & Commissioning of Optical Smoke Detector Conventional type completed with base plate (LPCB Listed ) Make Apollo and as specified in tender document & approved and directed by Engineer-In-Charge.
36
-
-
Supply,Installation,Testing & Commissioning of Siren Electric Siren 1 km Range 220 V and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Supply,Installation,Testing & Commissioning of Sprinkler Alarm valve Assembly with alarm Motor Gong. With necessary, sutaible flanges,gaskets,nuts/bolts etc and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Supply,Installation,Testing & Commissioning of Drain Valve 50 NB with necessary, sutaible flanges,gaskets,nuts/bolts etc and as specified in tender document & approved and directed by Engineer-In-Charge.
2
-
-
Supply,Installation,Testing & Commissioning of Pressure Gauges Burdon type pressure gauges With gauges cock male wares/ Febig 0-14 Rang SS hion dia gauge with siphon waree / Febig / H. Guru SS 4” Dall and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Supply,Installation,Testing & Commissioning of Quatzoid Bulb Sprinkler Supply & Installation of Sprinkler plain SS body UL Listed finish with suitable size Pendant type spray with Coupling Nut etc and as specified in tender document & approved and directed by Engineer-In-Charge.
96
-
-
Supply,Installation,Testing & Commissioning of Exith Light With Battery Backup Emergency Exit Light Sport Type with Battery Backup and as specified in tender document & approved and directed by Engineer-In-Charge.
3
-
-
Providing & Fixing Signages for No Smoking,Fire Extinguishers,Fire Buckets,Danger along with Emergency Telephone numbers,etc & Consultancy Charges For Site Supervion, Visits,Drawing Preparation,Proff checking from Fire Department,Silvassa,DNH ETC and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Design, Supply, Installation, Testing & Commissioning of POWER CABLES Suitable XLPE copper power/submersible cable from main panel to all the motors and as and where required for all the fire figthing equipments,etc, with proper lugs,gands,etc. Make- Havells, R.R.cable as approved and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications.(a) For Electrical Installation up to 440V in normal soil,Length of pipe - 1 Mtr,Back filling compound - 1 Nos Bag of 15 Kg.Inclu dingCopper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (E) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core). Make- Havells, R.R.cable and as specified in tender document & approved and directed by Engineer-In-Charge.
100
-
-
Laisoning charges for providing new Electric connection upto 95 KW load and getting necessary approval and Electrical connection released for Fire Fighting System from DNHPDCL and as specified in tender document & approved and directed by Engineer-In-Charge.
1
-
-
Excavation for foundation upto 1.5m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead as directed by the Engineer-In-Charge. (A) Loose or soft soil
227.5
-
-
Excavation for foundation for depth from 1.5m to 3.0m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead as directed by the Engineer-In-Charge. (A) Loose or soft soil
166.8
-
-
Providing and filling rubbles including hand packing and filling interstices with quarry spalls as directed by the Engineer-In-Charge.
15.18
-
-
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering lead upo 50 m and lift upto 1.5 m as directed by Engineer-In-charge.
394.3
-
-
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work as directed by Engineer incharge. (A) Foundations Footings Bases of Columns etc. and Mass concrete.
81.1
-
-
Providing and laying cement concrete 1:2:4 (1‐Cement:2‐Coarse sand:4‐graded stone aggregates 20 mm nominal size) and curing complete excluding cost of formwork as directed by Engineer-In-charge. (A) Foundation and Plinth.
20.2
-
-
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level as directed by Engineer in charge.
9673.65
-
-
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (C) Vertical surface such as walls (any thickness) partitions and the like including attached buttresses & string course & the like.
376
-
-
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (B) Flat surfaces such as soffits of supspened floors slabs Landings and the like. (1) Floors etc. upto 200 mm in thickness.
151.4
-
-
Providing and laying in position Ready Mixed M‐300 grade concrete for reinforced cement conctere work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer‐In‐charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 475 kg ).
41.8
-
-
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat sqm.
100
-
-
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.
66
-
-
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (1) Square Rectangular Polygonal in plan.
133.09
-
-
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams Beam Haunchings cantilevers Girders Bressumers and Lintels not exceeding 1 M. in Depth.
34.96
-
-
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete.
6
-
-
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (D) Columns, Pillars posts and struts, upto floor two level.
9.12
-
-
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced
concrete work in (B) Walls, from top of foundation level upto floor two level
14.4
-
-
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in © Slabs,landing,shelves,Balconies,
Lintels, Beams, Girders and Cantilever upto floor two level.
19.43
-
-
Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materials and disposal of unserviceable materials with all lead and lift.(i) G.I.sheet roofing.
20.4
-
-
Structural steel work ( Confirming to IS 4923‐1997) riveted, bolted or welded in builtup for all type sections, in framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all and with all necessary screws fittings etc complete as per the structural designs and directions of Engineer in charge.
1041.58
-
-
Providing corrugated G.I. sheet of class‐3 roofing fixed with glavanished iron J or L Hooks, Bolts and nuts 8mm diameter with bitumen and G.I. limpet washer or G.I. limpet washer. filled with white lead complete of make JSW, Essar or equivalent excluding the cost of purlins, Rafters and Trusses (0.8 mm)
159.13
-
-
Providing and fixing 150mm wide 450mm over all semicircular plain G.I.sheet class‐3 gutter with Iron brackets 40mm x 3mm size Bolts, Nuts, washers etc. including making necessary connection with rain water pipes. (i) 0.80 mm thick Sheet.
7.13
-
-
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(G)110 mm
24
-
-
Removing dry or oil bound distemper by a washing and scraping and sand papering the wall surface smooth including necessary repairs to scratches complete.
6350.17
-
-
Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on wall surfaces of given an even shade, over and including a priming coat of whiting
after thoroughly brooming the surface free from mortar dropping and other foreign matter.
4357.42
-
-
Finishing wall with water proofing cement paint of on wall surfaces (Two coats) to give an approved brand and manufacture and of required shape even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials.
2196.75
-
-
Painting one coats (excluding priming coat) on previously painted steel and other metal surface with enamel paint, brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
172.32
-
-
Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete.
1230.52
-
-
Providing and fixing 1.20 Metre high chain link fencing of size 2.5x2.5x2.5 mm with 1.8 Metre long M.S. Angle posts 45mm x 45 mm x6 mm and oil painting 3 coats fixed at 3.0 Mt,C/c. including MS gate with 50x50x6mm covered with chainlink 2.5x2.5x2.5 mm jali with wicket gate and frame strutted with column of angle post 75x75x6 mm including fixing the posts in ground with 0.5 M x 0.5.M x 0.5 M. block in C.C1:5:10 etc complete as directed.
1614
-
-
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1‐ Cement : 6 ‐finesand)
32.19
-
-
Providing 20mm thick cement plaster in single coat on single orhalf brick walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4
337.06
-
-
Provoding and fixing flush door shutters, solid core construction with frame of first class hardwood with cross board and face veneer or plywood face panels, including anodised alluminium butt hinges with necessary screws. (B) Non‐decorative type and block board core anodised alluminium butt hinges in flush door shutters (2) 35 mm thick.
3
-
-
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non‐pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(H) 900mm (upto 10 ton)
35
-
-
Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work
16.2
-
-
Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. Size having weight not less than 35Kg.
4
-
-
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
798.6
-
-
Evaluation Notes How It Works ?