State Warehousing Corporation - CGSWC Tender

Pipes and Pipe Related Activities
Opening Date12 May 2021
Closing Date3 Jun 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).

324.62

863164

2659

... More
Boring, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in cement concrete M-35 grade, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap):300 mm dia piles.

141.9

213559

1505

... More
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: Thermo-Mechanically treated bars FE 415

37934.91

2067452

54.5

... More
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. M-20 Grade

317.48

1343257

4231

... More
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: + M-20 Grade upto 4.00 m Above

70.32

304380

4328.5

... More
Above 4.00 upto 8.00 m Above

35.59

157521

4426

... More
Above 8.00 upto 12.00 m Above

0.56

2533

4523.5

... More
Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.

799.28

111099

139

... More
Window sills, anchor blocks, string course, bends, copings, bed plates and like.

9.01

1657

184

... More
Above 6.00 M. to 7.00 M.

1.35

357

265

... More
Above 7.00 M. to 8.00 M.

2.11

643

305

... More
Above 8.00 M. to 9.00 M.

2.11

730

346

... More
Above 9.00 M. to 10.00 M.

2.27

876

386

... More
Beams, lintel, cantilevers & walls.

29.28

5914

202

... More
Spiral / folded plate type stair cases including risers and landings

19.06

5851

307

... More
Suspended floor roof access plate form balconies (plain surface)and shelves(cast in situ)

106.74

25083

235

... More
Edge of slab breaks in floorand wall up to 200mm

69.62

2367

34

... More
Beams, lintel, cantilevers & walls.Up to 4.00 M. height from P.L.

160.32

32384

202

... More
Above 5.00 M. to6.00 m

53.17

15047

283

... More
Columns-rectangular or square in shape. (i) Up to 4m height

1130.31

335702

297

... More
Above 4.00 M. to 5.00 M.

91.04

30726

337.5

... More
Above 5.00 M. to 6.00 M.

64.82

24501

378

... More
Above 6.00 M. to 7.00 M.

20.38

8518

418

... More
Above 7.00 M. to 8.00 M.

10.56

4847

459

... More
Above 8.00 M. to 9.00 M.

2.8

1398

499.5

... More
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Sand)

172.74

563650

3263

... More
Extra for brick work In S/S above plinth & up to floor five level.

257.49

871352

3384

... More
Extra for brick work In S/S above 4.00 m & upto 8.00 M

159.18

557925

3505

... More
Extra for brick work In S/S above 8.00 m & upto 12.00 M

76.31

276700

3626

... More
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including formwork.

3.88

16435

4237

... More
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.

4199.17

1557892

371

... More
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50mm thick

469.62

119283

254

... More
75mm thick

1769.94

610629

345

... More
Extra for providing & fixing 4 mm. Thick glass strips in joints of Terrazzo floor/ cement concrete floor & or like.60 mm. Wide

2454.91

61372

25

... More
40 mm. wide

939.24

16906

18

... More
Providing 10cm. x 7.60 cm. drip course with specially moulded burnt bricks of crushing strength not less than 35 kg/sqcm and water absorption not more than 20% at junction of roof and walls in cement mortar 1:4 (1 cement 4 fine sand)

44.64

2131

47.75

... More
Providing and fixing float glass panes with steel glazing clips and special metal sash putty of approved make in steel doors, windows, ventilators. 4 mm. Thick

52.02

27830

535

... More
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft, with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring.80 x 1.25 mm. M.S. laths

71.44

120805

1691

... More
Extra for providing grilled rolling shutter manufactured out of 8 mm dia. M.S. bar instead of laths as per approved design (area of grill provided, only to be measured).

17.57

5745

327

... More
Providing and fixing 27.5cm. long wire spring for rolling shutters.

32

11584

362

... More
Providing and fixing M.S. sheet top cover for rolling shutter.0.90 mm. thick

42.84

17093

399

... More
Providing andfixing ball bearing for rolling shutters.

32

13536

423

... More
Providing and fixing factory made ISI marks steel doors, windows and ventilators side/ top/ centre hung made up of standard rolled steel section conforming to IS 1038:1968 (viz. F7D, F4B, K11 and K12B etc.), joints mitred and flash butt and sash bars tenoned and riveted/ welded with 10 cm long lugs of size 15x3mm embedded in cement concrete block 15x10x10 cms of 1:3:6 (1 cement :3 Coarse sand: 6 graded stone aggregate 20 mm nominal size) or rawl plugs and screws or with bolts and nuts as required including providing and fixing of hinges, pivots, handles, pegs, stays, rolling devices, locking arrangements, spring catch etc., as required complete including applying a priming coat of red oxide zinc chromate primer.

1235.58

99464

80.5

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.

870.13

58733

67.5

... More
Providing and fixing GI wire gauge of average width of aperture 1.56mm with wire of 0.45mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete.

40.23

22890

569

... More
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.In Angle-iron frames

531.35

39319

74

... More
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

203.75

14568

71.5

... More
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.

2924.16

273408

93.5

... More
Above 5.00 M. height.

22243.8

2139853

96.2

... More
Supply and fixing of precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

2297.58

1461260

636

... More
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Crimp curve

83.7

52228

624

... More
Providing and making 12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)

3607.6

330095

91.5

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

7.01

28551

4073

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)

150.87

16143

107

... More
Applying priming coat on steel work with red oxide zinc chromate primer.

153.84

2692

17.5

... More
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint

1598.13

87897

55

... More
Providing and making 6mm thick cement plaster of mix:n Cement mortar 1:4 (1 cement : 4 fine sand)

675.66

58782

87

... More
Providing and making moulded mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: 18 mm thick

78.76

441

5.6

... More
Extra for lining over plaster to imitate stone or concrete block walling

374.6

6031

16.1

... More
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.Size up to 200x300mm

39.73

23321

587

... More
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.Size 300x300mm

9.81

6788

692

... More
Providing and laying vitrified floor tiles with soluble salt printing, of size 600x600mm with water absorption less than 0.5% and conforming to IS : 15622 of approved make, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.

69.81

67227

963

... More
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.

1671.27

38439

23

... More
Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even.

425.14

40175

94.5

... More
Distempering with acrylic washable distemper to give an even shade. On new work (Two or more coats)

425.14

16155

38

... More
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.

1956.56

45000

23

... More
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

1956.56

109567

56

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For fixed portion

149.64

49530

331

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading.With float glass panes of 6 mm thickness

13.65

10974

804

... More
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).

6000

41200

7.2

... More
Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge.

10.5

3633

346

... More
Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification..PVC door shutter

3.36

7788

2318

... More
Wiring for light/ fan/ exhaust fan/ call bell point with 1.5 sqmm. FR PVC insulated stranded copper conductior single core cable in concealed steel conduit, with 5amp piano type swich, phenolic laminated sheet, suitable size M.S. box and earthing the point with same size cable etc as required. Short point

5

1180

236

... More
Medium point

34

13192

388

... More
Long point

12

6636

553

... More
Extra for providing and fixing light plug point on baard in concealed steel conduit point wiring with piano wiring with plano type 3pin 5Amp socket outlet and 5 Amp switdch i/c cost of phenolic laminated sheet and M.S. box etc. as required. 3 pin, 5 Amp. Socket outlet point on same board.

16

1520

95

... More
Wiring for light plug point with 2x2.5 sqmm. FR PVC insulated stranded copper conductor cable in concealed steel conduit allong with piano type 6amp switch and 3pin 6 amp socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size cable etc. as required. Short point

2

678

339

... More
Medium point

4

2328

582

... More
Long point

2

1738

869

... More
Wiring for power plug point with 2x4 sqmm. FR PVC insulated stranded copper conductor cable in concealed steel conduit allong with piano type 16amp switch and 6 pin 16 amp socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size cable etc. as required.Short point

1

501

501

... More
Medium point

1

846

846

... More
Long point

2

2518

1259

... More
Wiring for circuit / sub main wiring allong witrh earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed steel conduit as required. 3x2.5 sq. mm in 20 mm conduit

330

34320

104

... More
6x2.5 sq. mm in 20 mm conduit.

80

13760

172

... More
9x2.5 sq. mm in 20 mm conduit

20

4980

249

... More
Earhting with copper earth plate 600 mm X 600 mm X 3 mm thkick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe.

1

6754

6754

... More
Supplying and laying 8 SWG copper wire at 0.50 meter below ground level for conductor earth electrode, i/c solding etc. as required.

6

456

76

... More
Providing and fixing metal clad, SP&N switch fuse unit (re-wirable), 230/250 volts, with porcelain re-wireble fuse i/c drilling holes on the board, connections, earthing the body etc. as required. (Thimbeling shall be paid seperately) 32 amps

3

2793

931

... More
Supply and fixing on surface/ recess prewired vertical type following way, 415 volt TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete. Complete with loos wirew box, terminal blocks, 200amps tinned copper busbar, commen neutral link, earth bar, din bar, Supplying and fixing on surface/ recess prewired vertical type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland plate, loose wire box, superior make terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as required. (But without MCB/ RCCB/ Isolator) (Note: Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Single door

1

10020

10020

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing cubicle panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, testing and commissioning etc as required. (Connecting lead if required shall be paid separately) 100 Amp TP&N

1

3411

3411

... More
63 Amp TP&N

2

3256

1628

... More
32 Amp TP&N

2

2382

1191

... More
Supplying and fixing on surface/ recess following way, 240volts, SPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, i/c interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way, Single door

1

602

602

... More
Supplying and fixing on surface/ recess following way, 240volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, i/c interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door

1

2664

2664

... More
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as required.6 amps. to 32 amps

12

5136

428

... More
Supplying and fixing TP MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as required.6 amps to 32 amps

6

4176

696

... More
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.

4

1084

271

... More
Supplying and fixing following rating, 415 volts FOUR POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps.

2

1290

645

... More
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board i/c drilling holes on the board, screws, connections etc. as required. (Thimbeling shall be paid seperately). 100 amps.

4

1100

275

... More
Supply and laying following sizes one number PVC insulated, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground i/c excavation, sand cushioning, protective covering and refilling the trench etc as required. 4 X 25 Sq.mm.

30

9780

326

... More
4 x 10 Sq.mm.

50

13900

278

... More
Supplying and hanging following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on GI bearer wire (binded at every metre) including cost of bearer wire complete as required.4 x 25 sq. mm. on 7 SWG GI bearer wire.

30

5520

184

... More
Supplying and hanging following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on GI bearer wire (binded at every metre) including cost of bearer wire complete as required.4 x 10 sq. mm. on 8 SWG GI bearer wire

50

6750

135

... More
Supply and fixing metal clad busbar chamber made of 1.6mm. Thick CRCA sheet with 4 strip copper bushbar of following capacity and length, complete with all accessories, i/c earthing the body etc as required. 200 amp x 450 mm. Long

1

3531

3531

... More
Providing and fixing round/ hexagonal fan box (125 mm. dia) depth 75mm. (max) with 12 mm. dia steel bar hook, 1.6 mm. thiuck MS sheet cover, in RCC slab etc. as required

4

170

42.5

... More
Supplying and fixing metal box of following sizes (nominal size) in recess with suitable size phenolic laminated sheet cover in front i/c painting etc as required. 75 mm. x 75 mm. x 60 mm. deep

5

387

77.5

... More
100 mm. x 100 mm. x 60 mm. deep

4

374

93.5

... More
150 mm. x 75 mm. x 60 mm. deep

14

1386

99

... More
180 mm. x100 mm. x 60 mm. deep

9

1089

121

... More
200 mm. x 125 mm. x 60 mm. deep

4

896

224

... More
Supplying, instaling, testing and commissioning of following sizes ceiling fan with resistance type regulqator, i/c wiring the down fods of standard length up to 30 cm. with 1.5 sq. mm. FR PVC insulated, copper conductor, sinle core cable, earthing etc. complete as required. 1200 mm. sweep

4

6012

1503

... More
Supplying, installation, testing and commissioning of following T-5 fluorescent fitting (luminaries) complete with electronic ballast but without fluorescent lamp, on ceiling/wall surface, earthing the fitting etc. as required. Single box type with decorative end caps

24

6528

272

... More
Supplying, installation, testing and commissioning of following CFL down lighter luminaries wth mirror reflectore, but without CFL lamp, on surface / recess inb false ceiling i/c connection, testing and commissioning as required. For 1x13/18 watt CFL with cover

2

1934

967

... More
For 2x13/18 watt CFL with cover

4

4868

1217

... More
Exvavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.

37.64

6963

185

... More
In Hard rocks where blasting in prohibited

29.08

23205

798

... More
Providing and laying nominal mixed cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth & at ground level excluding cost of form work. 1:5:10 (1 cement : 5 course sand : 10 graded stone aggregate 40 mm. Nominal size)

8.16

19657

2409

... More
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)

11.92

31695

2659

... More
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:6 (1 Cement : 6 Sand)

27.1

88427

3263

... More
(B) Extra for brick work In S/S above plinth & up to floor five level.

42.48

143752

3384

... More
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including formwork.

0.74

3135

4237

... More
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete. a) Thrermo-mechanically

3822.78

208341

54.5

... More
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)

37.76

157194

4163

... More
Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement : 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement : 3 coarse sand) but excluding reinforcement.

1.58

741

469

... More
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :-(A) Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.

51.66

7180

139

... More
(b) Columns-rectangular or square in shape. (i) Up to 4m height

88.76

26361

297

... More
(C) Beams, lintel, cantilevers & walls.(i) Up to 4.00 M. height from P.L.

32.44

6552

202

... More
(D) weather shade chhajja cornies and moulding.

12.12

3563

294

... More
(E) Suspended floor roof access plate form balconies (plain surface)and shelves (cast in situ)

93.44

21958

235

... More
(F) Edge of slab breaks in floorand wall up to 200mm

70.9

2410

34

... More
Stair cases of all types excluding spiral and folded plate type, including risers and landings.Up to 4.00 M. height from P.L.

12.8

2944

230

... More
(C) Window sill,anchore string course bend coping bed plate and like (i) Up to 4.00 M. height from P.L.

9.68

1781

184

... More
(G) Stair cases of all types excluding spiral and folded plate type, including risers and landings (a) Up to 4.00 M. height from P.L.

66.72

4336

65

... More
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.

30.14

11181

371

... More
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (a) In Angle-iron frames

478.34

35157

73.5

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.

695.94

46975

67.5

... More
Providing and fixing factory made ISI marks steel doors, windows and ventilators side/ top/ centre hung made up of standard rolled steel section conforming to IS 1038:1968 (viz. F7D, F4B, K11 and K12B etc.), joints mitred and flash butt and sash bars tenoned and riveted/ welded with 10 cm long lugs of size 15x3mm embedded in cement concrete block 15x10x10 cms of 1:3:6 (1 cement :3 Coarse sand: 6 graded stone aggregate 20 mm nominal size) or rawl plugs and screws or with bolts and nuts as required including providing and fixing of hinges, pivots, handles, pegs, stays, rolling devices, locking arrangements, spring catch etc., as required complete including applying a priming coat of red oxide zinc chromate primer.

148.46

13064

88

... More
Providing and fixing float glass panes with steel glazing clips and special metal sash putty of approved make in steel doors, windows, ventilators: 4 mm. Thick

4.38

2343

535

... More
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.50mm thick

124.2

31546

254

... More
Extra for providing and fixing 4mm thick glass strip in joints of Terrazo floor/ cement concrete floor or like. 40 mm wide

111.66

2009

18

... More
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.Size 300x300mm

6.44

4456

692

... More
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size upto 200x300mm

32.34

18983

587

... More
25mm thick Local RAJIM/ Red Flag stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid over & jointed with grey cement slurry mixed with pigments to match the shade of the stone i/c grinding, rubbing and polishing.

2.76

1424

516

... More
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf)

25.42

46569

1832

... More
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm

12

2856

238

... More
Providing and fixing aluminium sliding door bolts with 16mm rod, necessary nickle plated iron nuts bolts and screws etc complete. 250x16mm.

4

564

141

... More
Providing and fixing aluminium tower bolts (Barrel type) with necessary nickle plated iron screws etc complete. 100 x10mm

2

89

44.5

... More
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 150 x10mm

16

920

57.5

... More
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 100 x10mm

22

902

41

... More
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 125 mm

12

270

22.5

... More
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 100 mm

20

440

22

... More
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Single

8

376

47

... More
Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws.24 mm thick door shutters with styles and rails of size 59x24 mm

3.22

7724

2399

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1: 1:5: 3 (1 cement : 1:3 coarse sand : 3 graded stone aggregate 40mm nominal size).

1.54

5470

3552

... More
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

444

40626

91.5

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

270.84

28979

107

... More
Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand)

181.08

15753

87

... More
Providing and making moulded mortar band in cement mortar 1:4 (1cement : 4 fine sand) per cm width: 12 mm thick

96.5

810

8.4

... More
Extra for lining over plaster to imitate stone or concrete block walling.

20.12

472

23.5

... More
Neat cement punning.

64.76

2137

33

... More
Distempering with acrylic washable distemper to give an even shade.On new work (Two or more coats)

384

14592

38

... More
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

439.38

24605

56

... More
Painting on new work (Two or more coats) to give an even shade with: Satin synthetic enamel paint

116.9

6429

55

... More
Providing and fixing vitreous china water closet squatting pan (Indian type) including cutting and making good the walls and floors wherever required:White Orissa pattern W.C. pan of size 580x440 mm

2

2880

1440

... More
`Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required :White size 450x325 mm

2

2406

1203

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :345x445 mm bowl depth 200 mm.

2

12596

6298

... More
Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with C.P brass nuts collar and PVC bush of approved quality and colour: 45 CM length

2

478

239

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia

4

274

68.5

... More
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 110 mm dia pipe.

44.7

11934

267

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm

26

4004

154

... More
(B) "P" trap 110mmx110mm long

2

454

227

... More
(e) Nahani trap

6

543

90.5

... More
(f) Vent covel (a) 110mm.

2

88

44

... More
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 25 mm dia. nominal bore

50

12900

258

... More
15 mm dia. nominal bore

10

1490

149

... More
Providing and fixing concealed in wall G.I. pipes medium class complete with G.I. fittings and clamps, including painting with anti corrosive bitumastic paint, cutting chases, making good the walls etc. and testing of joints complete: 15 mm dia nominal bore

10

1880

188

... More
20 mm dia nominal bore

10

2210

221

... More
Providing and fixing gun metal non- return valve (vertical type) of approved quality (screwed end) : 25 mm nominal bore

6

2706

451

... More
Providing and fixing stainless steel drain jali of approved make/quality.

4

204

51

... More
Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Bib cock (350 grams)

8

1896

237

... More
Stop cock (600 grams)

2

474

237

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

1000

7300

7.3

... More
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

4

6836

1709

... More
Wiring for light/ fan/ exhaust fan/ call bell point with 1.5 sqmm. FR PVC insulated stranded copper conductior single core cable in concealed steel conduit, with 5amp piano type swich, phenolic laminated sheet, suitable size M.S. box and earthing the point with same size cable etc as required. Short point

16

3776

236

... More
Medium point

12

4656

388

... More
Long point

4

2212

553

... More
Extra for providing and fixing light plug point on baard in concealed steel conduit point wiring with piano wiring with plano type 3pin 5Amp socket outlet and 5 Amp switdch i/c cost of phenolic laminated sheet and M.S. box etc. as required. 3 pin, 5 Amp. Socket outlet point on same board.

12

1140

95

... More
Wiring for light plug point with 2x2.5 sqmm. FR PVC insulated stranded copper conductor cable in concealed steel conduit allong with piano type 6amp switch and 3pin 6 amp socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size cable etc. as required. Short point

2

678

339

... More
Medium point

2

1164

582

... More
Long point

2

1738

869

... More
Wiring for power plug point with 2x4 sqmm. FR PVC insulated stranded copper conductor cable in concealed steel conduit allong with piano type 16amp switch and 6 pin 16 amp socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size cable etc. as required.Short point

2

1002

501

... More
Medium point

2

1692

846

... More
Long point

2

2518

1259

... More
Wiring for circuit / sub main wiring allong witrh earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed steel conduit as required. 3x2.5 sq. mm in 20 mm conduit

110

11440

104

... More
6x2.5 sq. mm in 20 mm conduit.

50

8600

172

... More
Earhting with copper earth plate 600 mm X 600 mm X 3 mm thkick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe.

2

13508

6754

... More
Supplying and laying 8 SWG copper wire at 0.50 meter below ground level for conductor earth electrode, i/c solding etc. as required.

12

912

76

... More
Providing and fixing metal clad, SP&N switch fuse unit (re-wirable), 230/250 volts, with porcelain re-wireble fuse i/c drilling holes on the board, connections, earthing the body etc. as required. (Thimbeling shall be paid seperately) 32 amps

2

1862

931

... More
Supplying and fixing on surface/ recess following way, 240volts, SPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, i/c interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way, Single door

2

1204

602

... More
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as required.6 amps. to 32 amps

8

3424

428

... More
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.

2

542

271

... More
4 x 10 Sq.mm.

40

11120

278

... More
Supplying and hanging following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on GI bearer wire (binded at every metre) including cost of bearer wire complete as required.4 x 10 sq. mm. on 8 SWG GI bearer wire

40

5400

135

... More
Providing and fixing round/ hexagonal fan box (125 mm. dia) depth 75mm. (max) with 12 mm. dia steel bar hook, 1.6 mm. thiuck MS sheet cover, in RCC slab etc. as required

4

170

42.5

... More
Supplying and fixing metal box of following sizes (nominal size) in recess with suitable size phenolic laminated sheet cover in front i/c painting etc as required.100 mm. x 100 mm. x 60 mm. deep

2

187

93.5

... More
150 mm. x 75 mm. x 60 mm. deep

2

198

99

... More
180 mm. x100 mm. x 60 mm. deep

2

242

121

... More
200 mm. x 125 mm. x 60 mm. deep

4

896

224

... More
Supplying, instaling, testing and commissioning of following sizes ceiling fan with resistance type regulqator, i/c wiring the down fods of standard length up to 30 cm. with 1.5 sq. mm. FR PVC insulated, copper conductor, sinle core cable, earthing etc. complete as required. 1200 mm. sweep

4

6012

1503

... More
Supplying, installation, testing and commissioning of following T-5 fluorescent fitting (luminaries) complete with electronic ballast but without fluorescent lamp, on ceiling/wall surface, earthing the fitting etc. as required. Single box type with decorative end caps

4

1088

272

... More
Supplying, installation, testing and commissioning of following CFL down lighter luminaries wth mirror reflectore, but without CFL lamp, on surface / recess inb false ceiling i/c connection, testing and commissioning as required. For 1x13/18 watt CFL with cover

4

3868

967

... More
Boring, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in cement concrete M-35 grade, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap):300 mm dia piles.

50.4

75852

1505

... More
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.In all types of soils.

1.25

231

185

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).

4.39

11673

2659

... More
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: Thermo-Mechanically treated bars FE 415

1006.01

54827

54.5

... More
Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.

24.78

2026

139

... More
Columns-rectangular or square in shape. (i) Up to 4m height

36.96

10977

297

... More
Suspended floor roof access plate form balconies (plain surface)and shelves(cast in situ)

26.06

6124

235

... More
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)

6.15

25594

4163

... More
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Sand)

1

3269

3263

... More
Extra for brick work In S/S above plinth & up to floor five level.

19.93

67443

3384

... More
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.

0.36

1525

4237

... More
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.

19.22

7130

371

... More
Extra for providing & fixing 4 mm. Thick glass strips in joints of Terrazzo floor/ cement concrete floor & or like.40 mm. Wide

94.3

1697

18

... More
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50mm thick

42.7

10845

254

... More
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.Size 300x300mm

23.87

16518

692

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

0.04

162

4073

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). In Super Structure

0.21

875

4170.5

... More
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

80

6000

75

... More
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.

493.12

43641

88.5

... More
Providing asbestos cement 6mm thick corrugated or semi corrugated sheets roofing fixed with galvanized J or L hooks, bolts and nuts 8mm dia G.I. plain bitumen washers complete excluding the cost of purlins, rafters and trusses.

56.24

19515

347

... More
Extra for providing and fixing wind ties of 40 x 6 mm flat iron section.

29.6

3492

118

... More
Providing and making 12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)

120.73

11046

91.5

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)

102.8

10999

107

... More
Providing and making 6mm thick cement plaster of mix:n Cement mortar 1:4 (1 cement : 4 fine sand)

6

522

87

... More
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.

229.53

5279

23

... More
Finishing walls with water proofing cement paint of required shade to give an even shade. On new work (Two or more coats applied @ 3.84 kg/10 sqm)

229.53

9410

41

... More
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint

17.59

967

55

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ),100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete include Coloured Orissa pattern W.C. pan of size 580x440 mm

4

14180

3545

... More
Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm

16

2464

154

... More
Vent covel. 75 mm

3

102

34

... More
"P" trap 110mmx110mm long

-

-

227

... More
Nahani trap 110x75mm

10

905

90.5

... More
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 110 mm dia pipe.

40

10680

267

... More
75 mm dia pipe.

50

9100

182

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 100 mm diameter S.W. pipe

40

14280

357

... More
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

3

5127

1709

... More
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type

4

5356

1339

... More
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: Flat back type urinal of size 460x380x250mm

3

4587

1529

... More
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x450 mm

4

5720

1430

... More
Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe.

1

1401

1401

... More
Providing and constructing brick masonry chamber for underground pipe and and bends with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line :

3

11388

3796

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 345x445 mm bowl depth 200 mm.

2

12596

6298

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia

6

531

88.5

... More
Providing and fixing PVC waste coupling in wash basin/ sink. 40 mm

6

366

61

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams)

10

3820

382

... More
Angle valve for basin mixer and geyser points (450 grams)

4

1528

382

... More
Long nose bib cock (500 grams)

4

1820

455

... More
Shower rose (revolving type) (150mm)

4

1076

269

... More
Stop cock (concealed) (600 grams)

20

9880

494

... More
Providing and fixing stainless steel drain jali of approved make/quality.

10

510

51

... More
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 40 mm nominal bore

4

2384

596

... More
25 mm nominal bore

2

872

436

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore

2

788

394

... More
15 mm nominal bore

2

568

284

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., 25 mm nominal outer dia .Pipes.

150

31950

213

... More
20 mm nominal outer dia .Pipes

80

13360

167

... More
15 mm nominal outer dia .Pipes

20

2660

133

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

4000

29200

7.3

... More
Boring, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in cement concrete M-35 grade, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap):

21

31605

1505

... More
Exvavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.

16.78

3104

185

... More
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.

7.19

2667

371

... More
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)

2.96

7870

2659

... More
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thrermo-mechanically treated bars.

649.22

35382

54.5

... More
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :Foundations, footing, base of columns and plinth beam in any shape and size.

14.98

2082

139

... More
Columns-rectangular or square in shape. (i) Up to 4m height

15.36

4561

297

... More
Beams, lintel, cantilevers & walls.Up to 4.00 M. height from P.L.

7.14

1442

202

... More
weather shade chhajja cornies and moulding.

3.11

914

294

... More
Suspended floor roof access plate form balconies (plain surface)and shelves(cast in situ)

27.57

6478

235

... More
Edge of slab breaks in floorand wall up to 200mm

17.3

588

34

... More
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)

6.18

25743

4163

... More
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Sand)

6.68

21783

3263

... More
Extra for brick work In S/S above plinth & up to floor five level.

12.95

43822

3384

... More
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.

0.22

932

4237

... More
Extra for providing and fixing 4mm thick glass strip in joints of Terrazo floor/ cement concrete floor or like.

13.5

243

18

... More
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50mm thick

16.58

4211

254

... More
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.Size 300x300mm

7.02

4854

692

... More
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size above 200x300mm

33.81

21841

646

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:2:3 (1 cement : 2 coarse sand : 3 graded stone aggregate 20mm nominal size).

0.04

162

4073

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). In Super Structure

0.16

667

4170.5

... More
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

200

15000

75

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.

25

1687

67.5

... More
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

97.66

8935

91.5

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

82.64

8842

107

... More
Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand)

14.03

1220

87

... More
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.

194.33

4469

23

... More
Distempering with acrylic washable distemper to give an even shade. On new work (Two or more coats)

96.67

3673

38

... More
Finishing walls with water proofing cement paint of required shade to give an even shade. On new work (Two or more coats applied @ 3.84 kg/10 sqm)

97.66

4004

41

... More
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint

7.44

409

55

... More
Exvavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.

7.11

1315

185

... More
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.

2.95

1094

371

... More
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)

1.39

3696

2659

... More
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thrermo-mechanically treated bars.

297.79

16229

54.5

... More
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :Foundations, footing, base of columns and plinth beam in any shape and size.

5.7

792

139

... More
Columns-rectangular or square in shape. (i) Up to 4m height

12.16

3611

297

... More
Beams, lintel, cantilevers & walls.Up to 4.00 M. height from P.L.

2.85

575

202

... More
weather shade chhajja cornies and moulding.

4.42

1299

294

... More
Suspended floor roof access plate form balconies (plain surface)and shelves(cast in situ)

6.29

1478

235

... More
Edge of slab breaks in floorand wall up to 200mm

11.7

397

34

... More
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)

3.05

12684

4163

... More
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Sand)

0.88

2871

3263

... More
Extra for brick work In S/S above plinth & up to floor five level.

5.13

17359

3384

... More
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.

0.1

423

4237

... More
Extra for providing and fixing 4mm thick glass strip in joints of Terrazo floor/ cement concrete floor or like.

9.5

171

18

... More
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50mm thick

4.63

1176

254

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:2:3 (1 cement : 2 coarse sand : 3 graded stone aggregate 20mm nominal size).

0.02

81

4073

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). In Super Structure

0.1

417

4170.5

... More
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.

816

76296

93.5

... More
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

100

7500

75

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.

50

3375

67.5

... More
Providing asbestos cement 6mm thick corrugated or semi corrugated sheets roofing fixed with galvanized J or L hooks, bolts and nuts 8mm dia G.I. plain bitumen washers complete excluding the cost of purlins, rafters and trusses.

6

2082

347

... More
Extra for providing and fixing wind ties of 40 x 6 mm flat iron section.

2

236

118

... More
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

41.55

3801

91.5

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

27.31

2922

107

... More
Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand)

6.73

585

87

... More
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.

75.59

1738

23

... More
Distempering with acrylic washable distemper to give an even shade. On new work (Two or more coats)

34.04

1293

38

... More
White washing with whiting to give an even shade. On new work (Three or more coats)

50

450

9

... More
Finishing walls with water proofing cement paint of required shade to give an even shade. On new work (Two or more coats applied @ 3.84 kg/10 sqm)

41.55

1703

41

... More
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint

4.28

235

55

... More
Exvavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.

476.06

88071

185

... More
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)

39.6

105296

2659

... More
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete. a) Thrermo-mechanically

14313.29

780074

54.5

... More
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :-(A) Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.

556.78

77392

139

... More
(b) Columns-rectangular or square in shape. (i) Up to 4m height

585.86

174000

297

... More
Window sill,anchore string course bend coping bed plate and like(i) Up to 4.00 M. height from P.L.

156

28704

184

... More
(C) Beams, lintel, cantilevers & walls.(i) Up to 4.00 M. height from P.L.

3.63

733

202

... More
weather shade chhajja cornies and moulding.

2.68

787

294

... More
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)

205.75

856537

4163

... More
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:6 (1 Cement : 6 Sand)

25.88

84446

3263

... More
(B) Extra for brick work In S/S above plinth & up to floor five level.

196.09

663568

3384

... More
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.

0.17

720

4237

... More
Providing and fixing M.S. frames of doors, windows, ventilators and cupboards joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Angle-iron frames

2754.87

202482

73.5

... More
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

56.37

4227

75

... More
Extra for providing and fixing 4mm thick glass strip in joints of Terrazo floor/ cement concrete floor or like. 40 mm wide

4.6

82

18

... More
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.50mm thick

5.29

1343

254

... More
Providing asbestos cement 6mm thick corrugated or semi corrugated sheets roofing fixed with galvanized J or L hooks, bolts and nuts 8mm dia G.I. plain bitumen washers complete excluding the cost of purlins, rafters and trusses.

7.5

2602

347

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

1249.91

133740

107

... More
Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand)

19.74

1717

87

... More
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

1263.95

115651

91.5

... More
Filling from available stuff (Excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20cm. in depth consolidating each deposited layer by ramming and watering with a lead up to 50M. and lift up to 1.5M.

401.86

26120

65

... More
Extra for lining over plaster to imitate stone or concrete block walling.

549.7

12917

23.5

... More
Painting exterior surface with PREMIUM ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with: On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

2862.48

213254

74.5

... More
Providing and fixing in position G.I. barbed wire (93.8gram/m) to concrete/ wooden/ angle iron posts (straight or diagonal) including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete(Cost of posts, struts to be paid for separately)

4200

39480

9.4

... More
Painting on new work (two or more coats) to give an even shade with: Aluminium paint

78.43

4588

58.5

... More
Providing and fixing in position door shutter made of square/ rectangular hollow steel tube of approved size joint mitred, welded frame with two Nos. intermediate rails, 200mm wide lock rail made of 1.6mm thick M.S. sheet welded to intermediate rail, M.S. grill of approved pattern made of M.S. flat or square or round bars welded to frames and provided M.S. butt hinges, all necessary fitting and finished by filling putty including applying a priming coat of red oxide zinc chromate primer all complete. (To be used in safety door shutters in buildings)

400

37400

93.5

... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth

990.85

144664

146

... More
Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads) P.C.C. M-10

8.46

23594

2789

... More
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) (a) 900mm dia

10

48740

4874

... More
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . )450mm dia

40

70760

1769

... More
Plain cement concrete complete as per drawing and Technical. PCC Grade M 15

24.24

91336

3768

... More
Granular Sub-base as per Table:- 400-1 Construction o granular sub base by providing close graded Mareial, , Carriage of mixed Material to work site spreading in uniform layers with motor grader on on perpared surface watering , rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401(part-II) and suitably sprinkling arrangement as per clause 401 but excluding scarifying existing bituminous surface.(A) By Mix in Place method. Disintegrated rock i.e moorum having CBB value not less than 20 and P.I. and L.L. not more than 6 and 20 respectively .

427.06

196447

460

... More
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)

588.33

843665

1434

... More
Dry Lean Cement Concrete Sub-base as per IRC:SP-49 (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)

255.8

596525

2332

... More
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub-base, coarse and fine aggregate conforming to IS:383, and graded as per table 600-3, mixed as per approved mix design at site, laid, spread, vibrated, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per clause 602.) (a) With Cement concrete grade M-40 and minimum cement content @ 400 kg/cum.

511.59

2408565

4708



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.