Eprocure
Opening Date11 Jun 2024
Closing Date26 Jul 2024
Tender Amount₹ 13,73,83,678 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
CIVIL CONSTRUCTION AND STRUCTURAL WORKS for 2X6.3 MVA, 33kV/3.3kV Substation on Turnkey Basis at SHIWANI UG, BHATGAON AREA inclusive of Insurance,Contingencie but excluding GST

-

-

-

... More
Sub-station Building

1

-

9379191.94

... More
Outdoor steel structures

1

-

2164032.28

... More
Foundation of outdoor structures including Transformer foundation

1

-

4257219.82

... More
Cable Trench

1

-

2013270.97

... More
Barbed wire fencing

1

-

33708.05

... More
Boundary wall

1

-

1808641.8

1

-

103750

1

-

2091818.88

... More
Surface dressing

1

-

85278.84

... More
Stone laying

1

-

1154706.38

... More
Anti weed treatment

1

-

43952.74

... More
Bore well with submersible pump

1

-

415000

... More
Path way

1

-

400008.23

... More
Security Room

1

-

182577.17

... More
RCC sump and Pump House

1

-

4474591.49

... More
Shed for DG & oil filter unit

1

-

355545.02

... More
Drain along boundary wall

1

-

651518.11

... More
Parking Shed

1

-

480466.25

... More
Oil Overflow Chamber

1

-

183691.16

... More
Oil Drain Pipe

1

-

22969.04

... More
Survey & Soil testing

1

-

146033.44

... More
SUPPLY OF PLANT & MACHINERY inclusive of Overhead Construction cost, Insurance, Contingencies , but excluding GST for substation ( 2X6.3 MVA, 33kV/3.3kV Substation )

-

-

-

... More
Isolators, 33 kV (nominal),3 poles, pole mounted, 1250A(min.), suitable fault current rating, arrangement for interlocking with 33 kV Vacuum Circuit breaker ( Min. 8 sets)

1

-

1420599.38

... More
Isolators, 33 kV (nominal), 3 poles, pole mounted, 1250A(min.), suitable fault current rating, arrangement for interlocking with 33 kV Vacuum Circuit breaker with Earthing switch ( Min. 2 sets)

1

-

375959.18

... More
Isolators, 33 kV (nominal), 3 poles, pole mounted, 1250A(min.) ,suitable fault rating, with D.O. Fuses. (Min. 4 sets)

1

-

843478.27

... More
Lightning Arrestors, station class, 30 kV,10 kA, suitable for 33kV, solidly earthed (each set consists of 3 nos.) with counters/surge monitors (Min. 6 sets)

1

-

117551.46

... More
Single phase current transformer ,outdoor type with required CT ratio for 33 kV system for metering and protection (1 set consists of 3 units for 3 phase supply) Min 5 sets

1

-

658609.8

... More
Potential transformer ,outdoor type 33kV, 100 VA each (each set consists of 3 nos. single phase PT) 33/√ 3 kV/ 110/ √ 3 V for metering and protection each for three phase system (Min. 2 sets)

1

-

145872.19

... More
Vacuum Circuit Breaker, 33kV,1250A, outdoor type, 25 kA min with remote control panel having IDMTL relay for O/L and E/F protection,,Digital type microprocessor based power meter, ammeter etc (Min. 5 sets)

1

-

4925891.13

... More
Power Transformer outdoor type plinth mounted 33/3.3kV, 6.3 MVA, ONAN cooled, DYn-11 conforming to IS:2026 (current) having ON-LOAD tap changer on HV side with all accessories including 33 kV remote control panel for on load tap changer as per IS:3639 (Current) with the rating as given below: Rated kVA: 6300 Rated Voltage(primary):33000V Rated Voltage(secondary):3.3kVV Connection and vector group:Dyn11 (Min. 2 Nos.)

1

-

7940848.91

... More
Neutral Grounding Resistor Monitoring System

1

-

1995181.52

... More
18 - Panels, 3.3 kV switch-board, indoor type with 18 nos. VCB panels, 630 A for incomer and sectionaliser , 630 A for outgoing , 150 MVA symmetrical breaking capacity. All panels will conform to IS:3427 (current) and relevent parts to IS:2516. These will be provided with cable end boxes. The incoming panels will be provided with restricted earth fault Protection. All panels will be provided with IDMTL relays for over current and earth fault protection. All incoming control circuit breaker shall be provided with Digital type microprocer based Power meter and outgoing control circuit breaker shall be provided with Digital type ammeter & energy meter.

1

-

4082350.87

... More
Station Transformer , Outdoor Type . 315 kVA , 33kV/0.415kV , Cu wound , plinth wound ( Min. 1 no.)

1

-

563303.82

... More
Lighting Transformer , Outdoor Type . 100 kVA , 33kV/0.230kV(L-L) , Cu wound , plinth wound ( Min. 1 no.)

1

-

350634.26

... More
230V(L-L) Main Lighting Distribution Board ( Min. 1 no.)

1

-

162128.29

... More
415V 3 Ph-N, switchboard , indoor type with 4 nos. MCCB having O/L , S/C, and E/L protection , 25 MVA symmetrical breaking capacity ( All outgoing panels will be provided with ammeter and incoming panel with ammeter and voltmeter). The function of panels will be as follows:- 1 no. , required rating MCCB , required CTR , as controller for incoming feered. 3 nos. , required rating MCCB , required rating CTR , as controller for outgoing feeders. ( Min. 1 no.)

1

-

496742.27

... More
Capacitor bank, 3.3kV indoor type (2100KVAR) Suitable Rating kVAR including APFC. (Min. 2 nos.)

1

-

2946659.76

... More
Battery (110 V) lead Acid type, 200 AH and battery charging (with one stand bye battery charging unit) equipment, control panels, wooden racks including DCDB etc. ( Min. 1 set.)

1

-

1068734.09

... More
Earthing system (Safe Earth Electrode type) including earth pits, required galvanised strips/flats,MS Rod for inter connection etc.

1

-

1788000

... More
Lightning protection system consisting of spikes, earth pits, galvanised strips/flats, shield conductors etc.

1

-

357600

... More
LUMINARIES

-

-

-

... More
Decorative, LED (Suitable rating) light fittings

1

-

29800

... More
Suitable rating LED Bulbs for indoor lighting

1

-

17880

... More
Tubular steel poles,11m height along with 90 W LED lamps with fittings ( minimum 7 nos.)

1

-

242901.41

... More
Lighting masts, 15m height (Min) along with required nos. of 200 W LED lamps with fittings.(min. one number mast) and Luminaires for Lightning cum Lighting Mast

1

-

916535.69

... More
90 W LED fitted on substation building(min. 4 nos.)

1

-

30992

... More
Emergency lighting system suitable for operation on 110 V DC supply in substation building.

1

-

149000

... More
Accessories such as lighting distribution boards, sub lighting distribution boards, junction boxes, individual control cables, PVC conduits/ casings, back up fuses, switches, sockets, ceiling roses, single core PVC cable with copper conductors, flexible wire etc.

1

-

309920

... More
CABLE AND ACCESSORIES

-

-

-

... More
HT Power Cable , 3.3kV , Copper Cable

1

-

2586927.22

... More
LT Power cable, 1100V grade, PVCSWA, 10 sq. mm.(minimum),3/4 core copper stranded conductors

1

-

1132400

... More
Outdoor Lighting cable, 1100V, PVCSWA , 2 cores, 10 sq mm (minimum) stranded Al conductors

1

-

1192000

... More
Outdoor and indoor Control cables, 1100V grade, PVCSWA, not less than 2.5 sq mm , copper conductors of with required number of cores

1

-

953600

... More
Wires for internal wiring of ,of illumination, ceiling fans, power sockets etc. 1.5 sq mm and 6 sq mm size, PVC insulated copper conductor cable of 1100 V grade.

1

-

298000

... More
Cables for internal control wiring for circuit breakers, CT’s, PT’s, PVC insulated cable 2.5 sq mm size, PVC insulated copper conductor of 1100 V grade

1

-

238400

... More
Cable trays, cable racks, binding materials, cable glands/lugs, cable jointing kit, bolts, nuts, washers, termination kit, other accessories etc.

1

-

381440

... More
Overhead conductors,Insulators, poles, string bus, ACSR conductors, clamps, terminal connectors, other steel hardware etc for 33 kV sides in the out door yard and 2 pole structure fitted with gang operated AB switch, lightning arrester etc for out going feeders

1

-

2026400

... More
FIRE FIGHTING SYSTEM

-

-

-

... More
Fire fighting equipment consisting of fire hydrants hose cabinets, hose reels, valves, pipes, fire detection alarming system, High velocity Water spray system for power transformers,diesel pump, electric pump with electricals and cables , jockey pump etc

1

-

3576000

... More
Supply of portable fire extinguisher system

1

-

23840

... More
Sand buckets with stand

1

-

11920

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Room air conditioners, min. 1.5 t capacity ( 5 star rating inverter compressor type ) including servo stabilizer

1

-

468147.14

... More
Supply of 63/62.5 kVA Diesel Generator set (silent type) with 3 ph, 50 Hz ,415 V output supply with cable, change over switch and earthing etc (Min. 1 no.)

1

-

761406.69

... More
Exhaust fans

1

-

26820

... More
BLDC Ceiling fan ,1200 mm sweep along with electronic regulator (5 star rating)

1

-

35760

... More
Water cooler with water purifier r (min 20 Ltr storage & 20 LPH cooling capacities) Min. 1 no.

1

-

23840

... More
Vacuum Cleaner Set (Min. 1 no.)

1

-

29800

... More
LOTO station system/kit-1 no. , Electrical Layout/Single Line Diagram Board , Electrical shock treatment Chart , Do's & Don’t Chart , Earth pit connection diagram with retro refractive radium type display , Danger plates , Furniture & fittings and insulating mat, First Aid chart & box, tool box, caution board, keyboard etc

1

-

357600

... More
Erection and commissioning of Plant and Machinary for substation to be suplied by bidder as above inclusive of Overhead Construction cost, Insurance, Contingencies , but excluding GST

1

-

4606147.54

... More
Training of O&M staff

1

-

21253.2

... More
Store cost for maintenance of P&M during Defect Liability Period (DLP) of five years.

1

-

3091374.18

... More
Cost of Operation & Maintenance during during Defect Liability Period (DLP) of five years.

1

-

28585932.03

... More
Total impact of GST for the purpose of CTC

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.