South Eastern Coalfields Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.
South Eastern Coalfields Limited - SECL Tender
Eprocure
Opening Date27 Aug 2021
Closing Date1 Oct 2021
Tender Amount₹ 10,73,78,451 This is an estimated amount, exact amount may vary.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_SECL_216014_1Bid Award Id
ViewTender No
SECL/BSP/CMC/e-Tender/468 Dt 26.08.2021Tender Authority
South Eastern Coalfields Limited ViewPurchaser Address
-Website
http://http://www.secl-cil.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
4. SPECIAL TERMS AND CONDITIONS (Applicable for Cl. No. 6 (A) titled as Work Experience of NIT)
BOQ Items
... More
CIVIL CONSTRUCTION AND STRUCTURAL WORKS for Substation-1 inclusive of Insurance,Contingencie but excluding GST
-
-
-
... More
Sub-station Building
1
-
11891539.69
... More
Outdoor Steel Structures
1
-
3375655.35
... More
Foundation of outdoor structures including Transformer foundation
1
-
1985820.3
... More
Cable Trench
1
-
2102663.78
... More
Barbed wire fencing
1
-
168540.23
... More
Boundary wall
1
-
2387407.17
... More
Gate
1
-
62250
... More
Road
1
-
2477154.28
... More
Surface dressing
1
-
90705.67
... More
Stone laying
1
-
1228188.35
... More
Anti weed treatment
1
-
46749.74
... More
Bore well with submersible pump
1
-
415000
... More
Path way
1
-
691372.26
... More
Security Room
1
-
182577.18
... More
RCC sump and pump House
1
-
4474591.49
... More
Shed for DG & Oil filter unit
1
-
355545.03
... More
Drain along boundary wall
1
-
860003.92
... More
Parking Shed
1
-
480466.25
... More
Survey & Soil testing
1
-
160367.38
... More
SUPPLY OF PLANT & MACHINERY inclusive of Overhead Construction cost, Insurance, Contingencies , but excluding GST for substation - 1 (2X12.5MVA,33kV/6.6kV )
-
-
-
... More
Isolators, 33 kV (nominal),3 poles, pole mounted, 1250A,13.1kA, arrangement for interlocking with 33 kV Vacuum Circuit breaker
4
-
227815.04
... More
Isolators, 33 kV (nominal), 3 poles, pole mounted, 1250A,13.1kA, arrangement for interlocking with 33 kV Vacuum Circuit breaker with Earthing switch
4
-
259510.32
... More
DO--but with earth switch and D.O. Fuses.
4
-
287987.2
... More
Lightning Arrestors, station class, 30 kV,10 kA, suitable for 33kV, solidly earthed (each set consists of 3 nos.) with counters/surge monitors
8
-
16938.32
... More
Single phase current transformer ,outdoor type with CT ratio of required capacity for 33 kV system for metering and protection (1 set consists of 3 units for 3 phase supply)
5
-
107589.92
... More
Potential transformer ,outdoor type 33kV, 100 VA each 33/√ 3 kV/ 110/ √ 3 V for metering and protection each for three phase system
2
-
76526.4
... More
Vacuum Circuit Breaker, 33kV,1250 A, outdoor type, 25 kA with remote control panel having IDMTL relay for O/L and E/F protection, ammeter,energymeter
5
-
630401.12
... More
Transformer outdoor type conforming to IS:2026 (current) having ON-LOAD tap changer on HV side and LV neutral effectively earthed through required value of Resistance ( Restricted Neutral System) with all accessories including 33 kV remote control panel for on load tap changer as per IS:3639 (Current) with the rating as given below Rated kVA: 12500; Rated Voltage(primary):33000V; Rated Voltage(secondary):6600V; Connection and vector group:Dy11
2
-
6213252.32
... More
6.6 kV switch-board, indoor type, 22 panel, with vacuum circuit circuit breakers,150 MVA symmetrical breaking capacity. The function of each panel is as given below: -2nos, 2000 amps circuit breaker panels having CT ratio of 1500/5 A for control of incoming feeders
-1 no. 2000 amps circuit breaker panel having CT ratio of 1500/5 A as sectionaliser
-3 nos1250 amps circuit breaker panel having CT ratio of 600/ 5 A for control of out going feeders to CHP/Inpit
-4 nos1250 amps circuit breaker panel having CT ratio of 400/ 5 A 400/5 A for control of out going feeders to Quarry pump
-4 nos 630 amps circuit breaker panel having CT ratio of 400/ 5 A for control of out going feeders to Quarry feeder
-1 nos 630 amps circuit breaker panel having CT ratio of 200/ 5 A for control of out going feeders to Workshop
-2 nos 630 amps circuit breaker panel having CT ratio of 400/ 5 A for control of out going feeders to for Quarry lighting
-2 nos. 800 amps circuit breaker panels having CT ratio of 500/ 5 A for control of out going feeders to capacitor banks with automatic power factor control facility.
-3 no. 1250 amps circuit breaker panels having CT ratio of 1500/ 5 A as reserve.
All panels will conform to IS:3427 (Current) and relevant parts to IS:2516 ( current). These will be provided with cable entry boxes. The incoming panels will be provided with restricted earth fault protection. All panels will be provided with IDMTL relays for over current and earth fault protction. The incoming and outgoing panels shall be provided with Trivector meters.
1
-
7261735.52
... More
Station Transformer, outdoor type rated as follows:
Rated kVA: 315
Rated Voltage(primary):33000 V
Rated Voltage(secondary):433 V, Cu wound, Plinth mounted
1
-
487325.36
... More
Lighting Transformer, outdoor type rated as follows
Rated kVA: 100
Rated Voltage(primary):33000 V
Rated Voltage(secondary):230V(L-L), plinth mounted
1
-
224608.56
... More
415V switch board, indoor type with 4 nos MCCB having O/L, S/C and E/L protection, 25 MVA symmetrical breaking capacity (All out going panels will be provided with ammeter, and incoming panel with ammeter and voltmeter). The function of panels will be as follows : - 1 no, MCCB, 800A, CTR of 300/5 A, as controller for incoming feeder. - 3 nos, MCCBs, 400A, CTR of 100/5 A, as controller for outgoing feeders.
1
-
414220
... More
230 V (L-L) Main Lighting Distribution boards with the following :
--1no. MCCB, 3 pole,400 amps for control of incoming feeder.
-3 nos.,MCBs, 2 pole,63 amps for control of out going feeders.
-3 nos.,MCBs, 2 pole, 32 amps for control of out going feeders.
1
-
155329.52
... More
Capacitor bank, 6.6kV indoor type 4125 kVAR including APFC.
2
-
5695483.28
... More
Battery (110 V) lead Acid type, 200 AH and battery charging (with one stand bye battery charging unit) equipment, control panels, wooden racks etc.
1
-
931381.12
... More
Earthing system (Safe Earth Electrode type) including earth pits, required galvanised strips/flats for inter connection etc.
1
-
1430400
... More
Lightning protection system consisting of spikes, earth pits, galvanised strips/flats, shield conductors etc.
1
-
357600
... More
Luminaries
-
-
-
... More
Decorative, 1x15/18W and 2x15/18 W LED light fittings
1
-
17880
... More
2x15/18 W LED Bulbs
1
-
17880
... More
Tubular steel poles,11m height along with 90 W LED lamps with fittings
1
-
128402.24
... More
Lighting masts, 16m height along with required nos. of 200 W LED lamps with fittings.
1
-
2462672
... More
90 W LED fitted on substation building
4
-
8344
... More
Emergency lighting system suitable for operation on 110 V DC supply in substation building.
1
-
178800
... More
Accessories such as sub distribution board, junction boxes, individual control cables, PVC conduits/ casings, back up fuses, switches, sockets, ceiling roses, single core PVC cable with copper conductors, flexible wire etc.
1
-
596000
... More
Cables and accessories
-
-
-
... More
HT power cable, 6600 V grade, XLPE, FRLS, stranded Copper conductor
1
-
3099200
... More
LT Power cable, 1100V grade, PVCSWA, 10 sq. mm. (minimum), 3/4 core copper stranded conductors
1
-
1072800
... More
Outdoor Lighting cable, 1100V, PVCSWA , 2 cores, 10 sq mm (minimum) stranded Aluminium conductors
1
-
596000
... More
Outdoor Control cables, 1100V grade, PVCSWA, not less than 2.5 sq mm , copper conductors of with required number of cores
1
-
596000
... More
Wires for internal wiring of 1.5 sq mm and 6 sq mm size, PVC insulated copper conductor cable of 1100 V grade.
1
-
596000
... More
Cables for internal control wiring of illumination, ceiling fans, power sockets etc. 2.5 sq mm size, PVC insulated copper conductor of 1100 V grade
1
-
476800
... More
Cable trays, cable racks, binding materials, cable glands/lugs, cable jointing kit, bolts, nuts, washers, termination kit etc.
1
-
596000
... More
Overhead conductors,Insulators,Towers, poles, insulators, string bus, ACSR conductors, steel hardware etc for 33 kV sides in the out door yard and 2 pole structure fitted with gang operated AB switch, lightning arrester etc for out going feeders
1
-
4768000
... More
Fire Fighting System
-
-
-
... More
Fire fighting equipment consisting of fire hydrants hose cabinets, hose reels, valves, pipes, fire detection alarming system, high velocity water spraying system for transformers,diesel pump, electric pump with electricals and cables , jockey pump etc
1
-
4768000
... More
Supply of portable fire extinguisher system
1
-
23840
... More
Sand buckets with stand
1
-
11920
... More
Miscellaneous items
-
-
-
... More
Room air conditioners, 2 t capacity ( 5 star rating ) including servo stabilizer
1
-
357600
... More
Supply of 63 kVA Diesel Generator set (silent type) with 3 ph, 50 Hz ,415 V output supply with cable, change over switch and earthing etc
1
-
658711.12
... More
Exhaust fans, 600 mm sweep.
1
-
26820
... More
Ceiling fan ,1200 mm sweep along with electronic regulator
1
-
10728
... More
Water cooler with water purifier
1
-
23840
... More
Erection and commissioning of Plant and Machinary for substation to be suplied by bidder as above inclusive of Overhead Construction cost, Insurance, Contingencies , but excluding GST
1
-
6327732
... More
Training of O&M staff
1
-
29196.65
... More
Operation & Maintenance of the entire substation (all inclusive) including supply of required manpower, spares and consumables during Defect Liability Period (DLP) of five years after commissioning of substation.
1
-
14676785.6
... More
Total impact of GST for the purpose of CTC
1
-
-
Evaluation Notes How It Works ?