South Eastern Coalfields Limited - SECL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Jul 2024
Closing Date29 Jul 2024
Tender Amount₹ 56,52,234 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(c) Group C

50

-

-

... More
2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2X2.5 sq.mm+1X2.5 sq. mm earth wire)

200

-

-

... More
3. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required

60

-

-

... More
4. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (a) 2 x 1.5 sq mm

200

-

-

... More
(b) 3x 2.5 sq mm

100

-

-

... More
5. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 MM

500

-

-

... More
(b) 32 MM

250

-

-

... More
6. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (a) 100 mm X 100 mm X 60 mm deep

25

-

-

... More
(a) 150 mm X 75 mm X 60 mm deep

20

-

-

... More
(b) 150 mm X150 mm X 60 mm deep

18

-

-

... More
(c) 180 mm X100 mm X 60 mm deep

15

-

-

... More
(d) 200 mm X125 mm X 60 mm deep

15

-

-

... More
7. Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required. (a) 5/6 A switch

250

-

-

... More
(b) 2 Way 5/6 A switch

50

-

-

... More
(c) 15/16 A switch

50

-

-

... More
(d) 3 Pin 5/6 A Socket Outlet

250

-

-

... More
(e) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked

250

-

-

... More
(f) Bell push, piano type ISI marked

20

-

-

... More
8. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

225

-

-

... More
9. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.

225

-

-

... More
10. Supplying and fixing brass batten/ angle holder including connection etc. as required.

225

-

-

... More
11. Supplying and fixing 5 A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole and neutral

100

-

-

... More
(b) Double Pole

50

-

-

... More
12. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps

20

-

-

... More
13. Supplying Lying , Drawing and connection of 2x6 sq mm PVC Aluminium Service Cable along with support of GI Wire(6swg) along with Connection on both side (From Pole to Main Switch of Quarter)

500

-

-

... More
14. Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required

20

-

-

... More
15. Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required.

200

-

-

... More
16. Cleaning , Decarbonising and re-connection of existing Service Cable Connection From Pole to Main Switch of Quarter each

100

-

-

... More
(B) Comprehensive Annual Maintenance Contract (CAMC) for the period of 365 Days for Day to Day Various Electrical Maintenance Jobs in Residential Quarters under Churcha Mine (RO) of Baikunthpur Area. - 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A

200

-

-

... More
(b) Group B

200

-

-

... More
(c) Group C

200

-

-

... More
2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2X2.5 sq.mm+1X2.5 sq. mm earth wire)

400

-

-

... More
3. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required

200

-

-

... More
4. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (a) 2 x 1.5 sq mm

600

-

-

... More
(b) 3x 2.5 sq mm

200

-

-

... More
5. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 MM

750

-

-

... More
(b) 32 MM

250

-

-

... More
6. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (a) 100 mm X 100 mm X 60 mm deep

100

-

-

... More
(a) 150 mm X 75 mm X 60 mm deep

150

-

-

... More
(b) 150 mm X150 mm X 60 mm deep

150

-

-

... More
(c) 180 mm X100 mm X 60 mm deep

100

-

-

... More
(d) 200 mm X125 mm X 60 mm deep

100

-

-

... More
7. Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required. (a) 5/6 A switch

1000

-

-

... More
(b) 2 Way 5/6 A switch

1000

-

-

... More
(c) 15/16 A switch

500

-

-

... More
(d) 3 Pin 5/6 A Socket Outlet

500

-

-

... More
(e) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked

500

-

-

... More
(f) Bell push, piano type ISI marked

100

-

-

... More
8. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

225

-

-

... More
9. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.

225

-

-

... More
10. Supplying and fixing brass batten/ angle holder including connection etc. as required.

225

-

-

... More
11. Supplying and fixing 5 A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole and neutral

100

-

-

... More
(b) Double Pole

100

-

-

... More
12. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps

100

-

-

... More
13. Supplying Lying , Drawing and connection of 2x6 sq mm PVC Aluminium Service Cable along with support of GI Wire(6swg) along with Connection on both side (From Pole to Main Switch of Quarter)

1000

-

-

... More
14. Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required

50

-

-

... More
15. Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required.

500

-

-

... More
16. Cleaning , Decarbonising and re-connection of existing Service Cable Connection From Pole to Main Switch of Quarter each

150

-

-

... More
(C) Comprehensive Annual Maintenance Contract (CAMC) for the period of 365 Days for Day-to-Day Various Electrical Maintenance Jobs in Residential Quarters under Pandavpara Colony of Jhilimili Sub Area, Baikunthpur Area. - 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A

150

-

-

... More
(b) Group B

120

-

-

... More
(c) Group C

120

-

-

... More
2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2X2.5 sq.mm+1X2.5 sq. mm earth wire)

300

-

-

... More
3. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required

200

-

-

... More
4. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (a) 2 x 1.5 sq mm

400

-

-

... More
(b) 3x 2.5 sq mm

200

-

-

... More
5. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 MM

450

-

-

... More
(b) 32 MM

200

-

-

... More
6. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (a) 100 mm X 100 mm X 60 mm deep

80

-

-

... More
(a) 150 mm X 75 mm X 60 mm deep

70

-

-

... More
(b) 150 mm X150 mm X 60 mm deep

70

-

-

... More
(c) 180 mm X100 mm X 60 mm deep

70

-

-

... More
(d) 200 mm X125 mm X 60 mm deep

60

-

-

... More
7. Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required. (a) 5/6 A switch

500

-

-

... More
(b) 2 Way 5/6 A switch

500

-

-

... More
(c) 15/16 A switch

250

-

-

... More
(d) 3 Pin 5/6 A Socket Outlet

300

-

-

... More
(e) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked

250

-

-

... More
(f) Bell push, piano type ISI marked

50

-

-

... More
8. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

100

-

-

... More
9. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.

100

-

-

... More
10. Supplying and fixing brass batten/ angle holder including connection etc. as required.

100

-

-

... More
11. Supplying and fixing 5 A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole and neutral

50

-

-

... More
(b) Double Pole

50

-

-

... More
12. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps

50

-

-

... More
13. Supplying Lying , Drawing and connection of 2x6 sq mm PVC Aluminium Service Cable along with support of GI Wire(6swg) along with Connection on both side (From Pole to Main Switch of Quarter)

600

-

-

... More
14. Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required

30

-

-

... More
15. Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required.

300

-

-

... More
16. Cleaning , Decarbonising and re-connection of existing Service Cable Connection From Pole to Main Switch of Quarter each

80

-

-

... More
(D) Comprehensive Annual Maintenance Contract for the period of 365 Days for day-to-day various Electrical Maintenance Jobs in Residential Quarter of Katkona Sub Area of Baikunthpur Area. - 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A

250

-

-

... More
(b) Group B

250

-

-

... More
(c) Group C

250

-

-

... More
2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2X2.5 sq.mm+1X2.5 sq. mm earth wire)

300

-

-

... More
3. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required

180

-

-

... More
4. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (a) 2 x 1.5 sq mm

450

-

-

... More
(b) 3x 2.5 sq mm

150

-

-

... More
5. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 MM

500

-

-

... More
(b) 32 MM

200

-

-

... More
6. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (a) 100 mm X 100 mm X 60 mm deep

100

-

-

... More
(a) 150 mm X 75 mm X 60 mm deep

100

-

-

... More
(b) 150 mm X150 mm X 60 mm deep

100

-

-

... More
(c) 180 mm X100 mm X 60 mm deep

100

-

-

... More
(d) 200 mm X125 mm X 60 mm deep

100

-

-

... More
7. Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required. (a) 5/6 A switch

600

-

-

... More
(b) 15/16 A switch

350

-

-

... More
(c) 3 Pin 5/6 A Socket Outlet

250

-

-

... More
(d) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked

350

-

-

... More
(e) Bell push, piano type ISI marked

60

-

-

... More
8. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

180

-

-

... More
9. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.

100

-

-

... More
10. Supplying and fixing brass batten/ angle holder including connection etc. as required.

150

-

-

... More
11. Supplying and fixing 5 A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole and neutral

100

-

-

... More
(b) Double Pole

100

-

-

... More
12. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps

100

-

-

... More
13. Supplying Lying , Drawing and connection of 2x6 sq mm PVC Aluminium Service Cable along with support of GI Wire(6swg) along with Connection on both side (From Pole to Main Switch of Quarter)

600

-

-

... More
14. Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required

50

-

-

... More
15. Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required.

500

-

-

... More
16. Cleaning , Decarbonising and re-connection of existing Service Cable Connection From Pole to Main Switch of Quarter each

150

-

-

... More
Total impact of GST for the purpose of CTC

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.