Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Opening Date21 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 30,00,702 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for providing and fixing light plug point on board in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with piano type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of phenolic laminated sheet and M.S. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

239

20554

86

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 6 amp switch and 3 pin 6 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.4.3 ) Long Point

13

9906

762

... More
Extra Long Point I

21

22323

1063

... More
Extra Long Point II

30

41910

1397

... More
Extra Long Point III

33

56496

1712

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 16 amp switch and 6 pin 16 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.5.1 ) Short Point

9

3735

415

... More
Medium Point

6

4224

704

... More
Long Point

7

7266

1038

... More
Extra Long Point I

9

13095

1455

... More
Extra Long Point II

4

7764

1941

... More
Extra Long Point III

6

15852

2642

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with 20amp 2 pole & earth, industrial type socket outlet, 32amp “C” curve SP MCB, in sheet steel enclosure with metal plug top and chained metal cover for the socket out let, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point

20

22100

1105

... More
Medium Point

2

3004

1502

... More
Long Point

3

5760

1920

... More
Extra Long Point I

5

12405

2481

... More
Extra Long Point II

7

22155

3165

... More
Extra Long Point III

6

22542

3757

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.7.1 ) Short Point

44

9988

227

... More
Medium Point

55

19085

347

... More
Long Point

27

12555

465

... More
Extra for providing and fixing light plug point on board in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

151

33522

222

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.10.1 ) Short Point

8

3416

427

... More
Medium Point

6

3606

601

... More
Long Point

13

11713

901

... More
Extra Long Point I

4

4840

1210

... More
Extra Long Point II

8

12440

1555

... More
Extra Long Point III

5

9395

1879

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.11.1 ) Short Point

3

1554

518

... More
Medium Point

9

7353

817

... More
Long Point

8

9256

1157

... More
Extra Long Point I

4

6340

1585

... More
Extra Long Point II

6

12294

2049

... More
Extra Long Point III

3

7476

2492

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 3 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.12.1 ) Short Point

1

638

638

... More
Medium Point

8

8360

1045

... More
Long Point

5

7565

1513

... More
Extra Long Point I

3

6315

2105

... More
Extra Long Point II

7

19250

2750

... More
Extra Long Point III

4

13496

3374

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.13.1 ) 3 X 1.5 sq. mm in 20mm conduit

88

5896

67

... More
3 X 2.5 sq. mm in 20mm conduit

155

13485

87

... More
6 X 2.5 sq. mm in 25mm conduit

121

18755

155

... More
9 X 2.5 sq. mm in 32mm conduit

118

25724

218

... More
12 X 2.5 sq. mm in 32mm conduit

85

22780

268

... More
3 X 4 sq. mm in 25mm conduit

180

23040

128

... More
6 X 2.5 sq. mm in 25mm conduit

121

18755

155

... More
6 X 4 sq. mm in 32mm conduit

77

16863

219

... More
6 X 6 sq. mm in 32mm conduit

89

26255

295

... More
Supplying and fixing following piano type switch, socket, other accessories on the existing switch box/ cover including connections etc. as per specification .5.1.1 ) 5/6 amps one way switch

18

450

25

... More
5/6 amps two way switch

77

2310

30

... More
Bell push

54

1620

30

... More
15/16 amps switch

64

3776

59

... More
3 pin 5/6 amp socket outlet

48

2016

42

... More
6 pin 15/16 amp socket outlet

89

6497

73

... More
Plug Top 3 pin 5/6 Amps (For light plug).

35

1330

38

... More
Plug Top 3 pin 16 Amps (For power plug).

69

3519

51

... More
Fan regulator Electronic, step type moving all round

40

5200

130

... More
Ceiling rose 3 pin 5 amps

39

1248

32

... More
Pendent holder

73

3066

42

... More
Batten/ angle holder

85

3230

38

... More
Providing and fixing composite board for computer points having piano type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch and 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable M.S box, 3mm thick phenolic laminated sheet cover including painting etc. as per specification.

54

29106

539

... More
Providing and fixing composite board for computer points having piano type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch and 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable size wooden box, 3mm thick phenolic laminated sheet cover including painting etc. as per specification.

72

25056

348

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.1 ) 5/6 amps one way switch

104

7176

69

... More
5/6 amps two way switch

307

26095

85

... More
Bell push

98

7840

80

... More
15/16 amp switch

117

10413

89

... More
3 pin 5/6 amp socket outlet

95

9120

96

... More
6 pin 15/16 amp socket outlet

83

9960

120

... More
6 pin 20 amp socket outlet

99

14256

144

... More
Fan regulator (one module size) electronic stepped type moving all rounds

97

18042

186

... More
Fan regulator (two module size) electronic stepped type moving all rounds

110

24530

223

... More
Plug Top (Deluxe type) 3 pin 5/6 Amps (For light plug).

201

14472

72

... More
Plug Top (Deluxe type) 3 pin 16 Amps (For power plug).

112

9520

85

... More
Plug Top (Deluxe type) 3 pin 25 Amps (For power plug).

93

6882

74

... More
25/32 amp A.C. Starter switch

11

2706

246

... More
Ceiling rose 3 pin 5 amp

89

3560

40

... More
Batten/ angle holder

102

4182

41

... More
Blanking plate

88

2464

28

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts electronic ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.33.1 ) For 36/40 watt T8 flu. Fitting

21

4935

235

... More
For 28 watt T5 flu. Fitting

16

5872

367

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts polyester filled copper wound ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.35.1 ) For 36/40 watt T8 flu. Fitting.

15

4080

272

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors in existing ceiling fans/ exhaust fan at all locations as per specification. P.F. should be greater than 0.9 6.38.2 ) 2.5 MFD

16

1808

113

... More
3.15 MFD

14

1596

114

... More
4 MFD

12

1392

116

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors for single phase motor at all locations as per specification. P.F. should be greater than 0.9 6.39.1 ) 6 MFD

20

2360

118

... More
8 MFD

33

3993

121

... More
10 MFD

24

3264

136

... More
12 MFD

41

5822

142

... More
15 MFD

27

3969

147

... More
20 MFD

36

5796

161

... More
25 MFD

17

3162

186

... More
30 MFD

15

2925

195

... More
Supply, Installation, testing and commissioning of following type LED Driver for LED Panel/down lights by approved make as required. 6.65.1 ) 3-6 watt

16

2016

126

... More
9-12 watt

31

4774

154

... More
15 watt

34

5916

174

... More
18/20 watt

42

8148

194

... More
36/40 watt

13

5005

385

... More
Supply, Installation, testing and commissioning of following type LED Driver for COB lights by approved make as required. 6.66.1 ) 6-15 watt

9

3897

433

... More
18/20 watt

7

3157

451

... More
30 watt

9

5247

583

... More
40 watt

9

5625

625

... More
50 watt

8

5848

731

... More
Supplying, installation, testing and commissioning of following RGBW LED Flood Light fitting (luminaries) IP 66 Rating, complete with electronic driver heat sink capacitor and all other accessories etc. as per specification. 6.67.1 ) 60 watt

22

208450

9475

... More
120 watt

18

310644

17258

... More
Supply, Installation, testing and commissioning of following type LED Driver for LED Street lights / Flood Lights, IP 65 by approved make as required. 6.68.2 ) 24 watt

44

18964

431

... More
36 watt

32

16256

508

... More
50 watt

23

14099

613

... More
Supplying and fixing metal clad busbar chamber made of 2.0 mm thick CRCA MS powder coated sheet with 4 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.8.1 ) 100 amps x 300mm long

15

25935

1729

... More
100 amps x 450mm long

4

10208

2552

... More
100 amps x 600mm long

3

9399

3133

... More
200 amps x 300mm long

3

7554

2518

... More
Providing and fixing metal clad, SP&N switch fuse unit (re-wirable), 230/250 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately) 7.9.1 ) 32 amps

9

8802

978

... More
63 amps

8

14096

1762

... More
Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.10.1 ) 32 amps

9

8334

926

... More
63 amps

5

9575

1915

... More
100 amps

6

20958

3493

... More
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.1 ) 16 amps

8

464

58

... More
32 amps

6

540

90

... More
63 amps

5

810

162

... More
100 amps

8

2320

290

... More
200 amps

6

3264

544

... More
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.2.1 ) 4 way, Single door

10

5670

567

... More
8 way, Single door

4

2816

704

... More
12 way, Single door

9

7290

810

... More
16 way, Single door

7

6671

953

... More
4 way, Double door

5

3920

784

... More
8 way, Double door

7

6622

946

... More
12 way, Double door

9

9909

1101

... More
16 way, Double door

7

9373

1339

... More
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.1 ) 4 way Single door

13

17121

1317

... More
6 way Single door

6

9594

1599

... More
8 way Single door

8

15696

1962

... More
4 way Double door

4

6864

1716

... More
6 way Double door

9

18342

2038

... More
8 way Double door

8

20376

2547

... More
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1 ) 6 amps to 32 amps

55

8305

151

... More
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.19.2 ) 40 amps

8

2112

264

... More
63 amps

9

3033

337

... More
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.1 ) 40 amps

9

5112

568

... More
63 amps

8

4968

621

... More
100 amps

9

5823

647

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

6

19458

3243

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

5

18670

3734

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

19

117971

6209

... More
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification.

239

18403

77

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.5.3 ) 2 x 10 sq. mm

235

24910

106

... More
4 x 10 sq. mm.

155

18445

119

... More
4 x 16 sq. mm.

156

19656

126

... More
4 x 25 sq. mm.

153

22338

146

... More
Supply and fixing of approved make wall mounting type voltage stabilizer with input volts 160-250, output volts 200-240 volts and double step relay on desired location with necessary fixing material including connection etc complete as per specification. 24.7.1 ) 4 KVA

8

30656

3832

... More
5 KVA

7

30569

4367

... More
Dismentaling, Shifting, Re-installation, testing and commissioning of split type Air Conditioner unit with indoor and out door units and frames at desired locations with existing length of copper piping with insulation, necessary wiring with existing cable etc complete as per specification.

11

34639

3149

... More
Supply, connecting and fixing extra length of copper piping for split type air conditioners of following dia and approved quality with insulation sleave etc complete as per specification 24.10.2 ) 1/2 "

20

4820

241

... More
1/4 "

20

3740

187

... More
Supplying and fixing good quality powder coated MS frame for installation of out door unit of split type Air Conditioner at desired location with atleast 6 nos steel fastners etc complete as per specification

28

12180

435

... More
Supplying, connecting and fixing 15mm dia PVC flexible drain pipe (reinforced with nylon threads) in drain outlet of split type air conditioners etc complete as per specification

61

854

14

... More
Servicing of split-type air conditioner unit of all capacity by cleaning of cooling and condensing units, filters, grills and other parts, oiling/ greasing of fan motor including testing etc as per specification.

23

13915

605

... More
Replacing the burnt/ wornout sealed compressor of Window/ split type AC unit with company repaired compressor including filling of refrigrent testing for leakage, testing and commissioning of AC unit etc as per specification. 24.15.3 ) 1.5 ton split type AC

18

151758

8431

... More
2.0 ton split type AC

15

135840

9056

... More
Supply and filling up required quantity of R-22/R-32/R-410 refrigrent in existing window/ split air conditioners as per manufacturers specification including checking for leakage before and after filling, flushing the line with R-22/R-32/R-410 etc complete as per specification. 24.17.3 ) 1.5 ton split type AC

12

11280

940

... More
2.0 ton split type AC

12

11916

993

... More
Supplying, fixing, testing and commissioning of following 440 volts capacitors in WT/ Split / Tower airconditioners at all locations as per specification. 24.18.1 ) 36 MFD

14

7070

505

... More
50 MFD

16

7472

467

... More
Supplying and replacing following spares/ accessories in window/ split AC 24.19.1 ) Electronic control PCB for WT/AC

9

10602

1178

... More
Electronic control PCB for Split/AC

15

22215

1481

... More
Digital Display Unit for WT/Split AC

14

24962

1783

... More
Blower motor for indoor unit of Split AC

18

27558

1531

... More
Fan motor for outdoor unit of Split AC

19

32908

1732

... More
Fan motor blade for outdoor unit of Split AC

17

10608

624

... More
Swing motor for WT/ Split AC

22

10406

473

... More
Remote for WT/ split AC

22

8690

395

... More
Dead Nut 1/4"

18

1116

62

... More
Dead Nut 1/2"

19

1368

72

... More
Dead Nut 5/8"

18

1656

92

... More
Installation, testing and commissioning of wall mounted storage type electric geyser including inlet / outlet water pipe connection, electric connection etc. as per specification.

19

3610

190

... More
Annual servicing of split- type (inverter and non inverter) air conditioners unit of all capacity by cleaning of cooling and condensing coils, filters, grills and other parts, oiling/ greasing of fan motor , checking for leakage including testing and gas charging etc complete as per specification

10

23360

2336

... More
Repainting of air cooler by scraping of old paint, making surface even, painting with red oxide primer & two coats of enamel paint of required shade complete.

17

5304

312

... More
Providing and replacing burnt/ damaged with new water pump in existing air cooler etc complete.

20

3980

199



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.