Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Public Works Department - PWD Tender

Electrical and Electronics
Opening Date28 May 2019
Closing Date20 Jun 2019
Tender Amount₹ 17,79,76,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(ii) Secondary Pumping for (2W+1S) For 24 HR Capacity of Each Pump LPM - 2268,Pump Head (Mt) - 50,Pump Efficiency- Not less than 75%,VFD & DPT Drive, Maximum Permissible Speed- 1450 RPM Total Pumps Head given below minimum required for the system. Actual static pressure shall be calculated & confirmed by the vender at time of Bidding.

3

-

-

... More
CONDENSOR WATER PUMPS Supply, installation, testing and commissioning of Horizontal split casing centrifugal Condenser water pump Sets with bronze impeller for condenser water recirculation of 4550 LPM,Pump Head 25 Mtr Max.permissible speed 1450 RPM and efficiency not less than 75% complete with TEFC EFF 1 Squirrel Cage induction motor suitable for 415 +-10% V, 50 cycles, 3 phase power supply with class F insulation, base plate, coupling guard, vibration isolators, SS Shaft,factory fitted mechanical seal etc.conforming to technical specification & The system shall be complete in all respects including the anti-vibration pads, flexible expansion bellows at both ends, suction guide vanes etc. and suitable for following ratings as per specifications as per following parameters.

3

-

-

... More
COOLING TOWERS Supply,installation, testing &commissioning of CTI Certified FRP induced draft cross flow cooling tower of capacity 1400 USGPM (350TR )Hot water inlet temp 36.39 °C/outlet water temparature 32.22 °C,Evaporation loss 0.75 % USGPM 10.5,Drift loss 0.005 % USGPM 0.07 , having No. of cell per tower should be minimum 2 /omplete with sump & steel ladder, EFFC IP-55 weatherproof type fan motors (HP of C/T Fan Motor 2 x 7.5HP speed 548 RPM ) suitable for 415 V, 3 phase, 50 Hz. MS Structure for mounting Cooling Tower, access arrangement for cooling tower interior, cement concrete foundation, steel / masonry support structure, anti vibration mountings etc. The starter, isolating switch & panel near cooling tower to be included in main electrical panel price, i.e. in the Detailed Bill of Quantities). The cooling tower shall conform to technical specifications Section. It should be complete as per directions of Engineer-In-Charge.(350TR (3W+1S)

3

-

-

... More
HOT WATER GENERATOR Supply, installation, testing and commissioning of package type Electric Hot Water Generator 100 kW microprocessor based step controller constructed out of 1.6 mm steel CRCA MS sheet (as per specifications) having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with minimum 50 mm thick fibre glass insulation 24kg /cmt density finished with 0.63mm /24G aluminum cladding sheet. The generator shall have electrical capacity of 100 kW Water In/Out Temp-50 deg C/55 deg C.heater bank provided in 3 steps The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

2

-

-

... More
HOT WATER PUMPS Supply, installation ,testing and commissioning of Horizontal Split Casing Hot water centrifugal pump Sets of capacity 397 LPM and pump head 50 mtr with SS impeller for chilled water recirculation complete with TEFC Sq.Cage induction motor with class F insulation, base plate, coupling guard, vibration isolators, SS Shaft, factory fitted mechanical seal etc.conforming to technical specification & as per following parameters.The chilled water pumps shall also include the cost of thermal insulation and aluminium cladding

3

-

-

... More
AIR & DIRT SEPRATOR SITC of Air & Dirt Separator shall be of a solid and robust construction (Mild Steel).It shall be able to remove free air and microbubbles as well as remove solid particles upto 5 microns from water at Velocity between 2-3m/s. Removal of Air & dirt shall be through coalescence. The unit shallbe able to condition the water to make it highly absorptive at all points in the system .This ensures that microbubbles can no longer exist at any point in the system. All connections, fittings and heads shall be of carbon steel. The medium used to de-aerate and remove dirt shall be manufactured of Steel Tube & a mesh made of copper wire. This medium should be non clogging in nature. An automatic air vent of at least 100mm free area to be connected at the top for the release of the air separated from the water. PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

1

-

-

... More
PART B - HIGH SIDE PIPING WORK Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold Setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

200

-

-

... More
(28.3.4) 250 mm dia (75mm thick Insulation)

50

-

-

... More
(28.3.5) 200mm dia (75mm thick Insulation)

215

-

-

... More
(28.3.6) 150mm dia (75mm thick Insulation)

200

-

-

... More
(28.3.7)125mm dia (75mm thick Insulation)

75

-

-

... More
(28.3.8) 100 mm dia (50mm thick Insulation)

80

-

-

... More
(28.3.9) 80mm dia (50mm thick Insulation)

125

-

-

... More
(28.3.10) 65mm dia (50mm thick Insulation)

90

-

-

... More
(28.3.11) 50mm dia (50mm thick Insulation)

85

-

-

... More
(28.3.12) 40mm dia (50mm thick Insulation)

110

-

-

... More
CHILLED WATER INSULATED VALVES WITH ABOVE SPECIFICATION Supplying, fixing, testing & commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the onnected piping and adequately supported as per specifications. Butterfly Valve (Manual) with CI Body SS disc, Nitrile Rubber Seal & O-Ring PN-10 presure rating for chilled water water circulation as specified. ALL BUTTERFLY VALVES ABOVE 150 MM DIA SHALL BE GEAR OPERATED Supplying, fixing, testing and commissioning of following size BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water line duly insulated to the same specifications as the connected piping and adequately supported as per specifications. (28.7.1) iii 200 mmDia

26

-

-

... More
(28.7.2) iv 150 mm Dia

2

-

-

... More
(28.7.4) v 100mm Dia.

2

-

-

... More
(28.7.5) vi 80 mm Dia

12

-

-

... More
(i)300 mm Dia.

2

-

-

... More
(ii) 250 mm Dia

2

-

-

... More
Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20 mA electric signal and providing similar transducedfeedback output to control system as required (16.11.3.2 ) a 300 mm dia

2

-

-

... More
250 mm Dia

2

-

-

... More
c 200mm Dia

26

-

-

... More
d 150 mm Dia

2

-

-

... More
e 100 mm Dia

2

-

-

... More
f 80mm Dia

12

-

-

... More
Supplying, fixing, testing and commissioning of following size BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water/ hot water line duly insulated to the same specifications as the connected piping and adequately supported as per specifications. (28.8.1) 200 mm Dia.

5

-

-

... More
(3(b) i) 300mm Dia

1

-

-

... More
Motorized Balancing Valve with actuator on /off Type with CI Body SS disc, Nitrile Rubber Seal & O-Ring PN-10 presure rating for chilled water circulation as specified. (a) 300 mm Dia.

1

-

-

... More
250 mm Dia.

1

-

-

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum (16.11.4.1) 150 mm Dia

1

-

-

... More
( 16.11.4.3)100mm Dia

1

-

-

... More
(16.11.4.4)80mm Dia

3

-

-

... More
Supplying, fixing, testing and commissioning of following size Y-STRAINER of Ductile CI Body flanged ends with stainless steel strainer for for chilled water/ hot water line duly insulated to the same specifications as the connected piping and adequately supported as per specifications. (28.10.1) 200 mm Dia

8

-

-

... More
80mm Dia.

3

-

-

... More
Supplying, fixing, testing and commissioning of following size NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled water/ hot water line duly insulated to the same specifications as the connected piping and adequately supported as per specifications. (28.9.1) 200 mm Dia

8

-

-

... More
(28.9.5) 80mm Dia

3

-

-

... More
CONDENSOR WATER PIPING Supplying, fixing, testing and commissioning of CONDENSER WATER PIPES of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. C class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. (28.13.1) 300mm Dia

90

-

-

... More
(28.13.2) 250 mm Dia

180

-

-

... More
(28.13.3) 200 mm Dia

90

-

-

... More
(28.13.4) 150mm Dia

50

-

-

... More
(28.13.6) 100mm Dia

50

-

-

... More
350mm Dia.

200

-

-

... More
(5 vi) 50 mm Dia

50

-

-

... More
CONDENSOR WATER VALVES (WITHOUT INSULATION) Supplying, fixing, testing and commissioning of following size BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water line duly insulated to the same specifications as the connected piping and adequately supported as per specifications. 300 mm Dia.

3

-

-

... More
250mm Dia.

16

-

-

... More
Supplying, fixing, testing and commissioning of following BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O-ring & PN 16 pressure rating for condenser water circulation as per specifications. (28.14.1) 200 mm Dia.

3

-

-

... More
150mm Dia.

32

-

-

... More
50mm Dia.

7

-

-

... More
Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC ,and upto 20 mA electric signal and providing similar transduced feedback output to control system as required. (16.11.3.2 ) 300mm dia

3

-

-

... More
(16.11.3.3) 250mm Dia

16

-

-

... More
(16.11.3.4) 200mm dia

3

-

-

... More
(16.11.3.5) 150mm Dia

30

-

-

... More
(16.11.3.7) 50mm dia

7

-

-

... More
Supplying, fixing, testing and commissioning of following size BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water/ hot water line duly insulated to the same specifications as the connected piping and adequately supported as per specifications. (28.8.2) 150 mm Dia

8

-

-

... More
Providing, fixing in position and testing of Balancing valves complete with necessary fitting like flanges, gasket and hardware like nut, bolts and washer. (PN-16) (20.1) 250 mm dia

4

-

-

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum (16.11.4.1) 150 mm Dia.

14

-

-

... More
Supplying, laying/ fixing of following thickness closed cell elastrometric nitrile rubber of class O applied by adhesive confirming to standard specifications and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required complete in all respect. (28.5.1) 32mm

50

-

-

50

-

-

... More
Providing, fixing in position and testing of Non Return valves complete with necessary fitting like flanges, gasket and hardware like nut, bolts and washer. (PN-16) (i) 200 mm Dia

4

-

-

... More
Supply & fixing of M.S Pot Strainer complete with SS bucket,fanged end connection as per specification :- for 350 mm Dia Pipe

1

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

8

-

-

... More
Providing & fixing in position the mercury in glass industrial type thermometers.

8

-

-

... More
Supply, Installation, Testing, & Commissioning of Automatic air vent with ball valve in brass construction complete with nipples, union etc. as required at all high points in the pipe lines. The valve shall be such as to have non-return valve as integral part of the vent. (6 (e) (i)10 mm dia auto air vent valve

8

-

-

... More
Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as required. 26.7.7) 25 mm Dia

10

-

-

... More
EXPANSION TANK FOR HOT & CHILLED WATER Providing and installation of open type expansion tank, FRP lined, fabricated out of 3 mm thick M.S. plate construction, duly insulated as per the specifications and shall be complete with 50mm system connection and overflow, drain, vent connections, valves and fittings as required. Insulation shall be covered with sand cement plaster and water proofing. SIZE : 1000 MM X 1000 MM X 1000 MM

2

-

-

... More
PART C HIGH SIDE ELECTRICAL PANEL WORK. (i) For 3 x300 TR Rotary Screw Water Chilling M/C (3W +1S ) (ii) For 3x 15 HP Primary Pumps (2W+1S ) (iii) 3# 50HP secondary pumps for 24 hr (2W+1S) (iv) For 3 x 40 HP CDW Pumps (2W+1S) (v)For 3 x( 2 #7.5 HP each ) Cooling Tower -350TR (2W +1S) (vi) For 3x 100 kW Hot Water Generator (2w+1S ) (vii) For 3 x 5 HP Hot Water Pumps (2W+1S) Supply, Installation, Testing & Commissioning of BMS Compatible Cubical type sectinalised floor standing switch Board of 50KA fault capacity at 415 V complete made out 2.0 mm thick CRCA Sheet With 3.5 strip 3 x 1200A capacity Aluminium Bus- Bar Electrolytic grade cable alley switchgears of following capacity & as per specifications. PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

1

-

-

... More
POWER & CONTROL CABLING AND EARTHING Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 40x3 mm MS flat clamp and steel dash fastener/ G.I. bolts and nuts as required. (17.7.4) 3.5 x 300 sq. mm. (For Hot Water Generator 100 Kw)

430

-

-

... More
3.5 x 400 sq. mm.(For Rotary Screw Water- Cooled Chilling M/C )

750

-

-

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing masonry open duct as required. (17.4.7)3 x 10 sq. mm (For Primary Pumps & Cooling Tower)

850

-

-

... More
3 x 35 sq. mm (For Condenser Water Pumps )

700

-

-

... More
3.5 x 50 sq. mm.( For Secondary Water Pumps )

830

-

-

... More
Supplying and installing following size powder coated, perforated M.S. cable trays with perforation not more than 17.5% rigidly suspended from the ceiling with M.S. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as required. (20.1.1) 100 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

300

-

-

... More
225 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

450

-

-

... More
375 mm width X 50 mm depth X 2.0 mm thickness

100

-

-

... More
450 mm width x 50 mm depth X 2.0 mm thickness

300

-

-

... More
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ concealed, steel/ PVC conduit/ PVC casing caping as required. (5.11.11) 2 x 2.5 sq. mm

400

-

-

... More
8 x 2.5 sq. mm

400

-

-

... More
10 x 2.5 sq. mm

400

-

-

... More
Supplying and fixing of following sizes PVC conduit along with accessories in surface complete as required. (4.15.2) 25 mm

400

-

-

400

-

-

400

-

-

... More
Supplying and laying following sizes one number PVC insulated, PVC sheathed, steel armoured, copper conductor controle cable of 1.1 KV grade in exiting PVC/ GI pipe etc as required. (17.13.1) 2 x 1.5 sq. mm

680

-

-

... More
Earthing Strip / Wires. Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as required.

45

-

-

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.(For looping in the equipment)

2010

-

-

... More
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as required.

800

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as required.

1700

-

-

... More
LOW SIDE AIRCONDITIONING WORK Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

1

-

-

... More
CS AHU-3F /53, CS AHU-3F /54 1x3000CFM /6RD/6.3 TR. /50mm Static /2.2kw

1

-

-

... More
CS AHU-2F /24 , CS AHU-3F /55 & 56 1x4000CFM /6RD/8.8TR /50mm Static /2.2 KW

3

-

-

... More
CS AHU-3F /28 , CS AHU-3F /30&31 , CS AHU-3F /43 ,44 & 45 1x5000CFM /6RD/9.9TR /50mm Static /3.7 Kw

7

-

-

... More
CS AHU-3F /41 , CS AHU-3F /57 1x6000CFM /6RD/13.9TR /50mm Static /3.7 KW

2

-

-

... More
Double Skinned Floor Mounted Air Handling Units Supply, installation, testing and commissioning of factory fabricated Double Skinned Chilled Water Air- handling unit Ceiling suspended type fabricated out of extruded aluminium section with 0.63mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.63 mm plain Galvanised steel sheet inside with blower, Plug fan /blower section anddirectdriven / blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row cooling coil made of Aluminium finned Copper tube with coil section,with following filtration level, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor and belt drive package etc. without face and bypass dampers. The AHU panels shall be insulated with 23 mm thick & 36 Kg/m³ density PU foam. PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

1

-

-

... More
FM AHU-1F /09 & 10 , FM AHU-2F /19/ 1x7000CFM / /6RD CC/2RDHC/16.8TR /70mm Static/5.5 KW

1

-

-

... More
FM AHU-1F /17&18, FM AHU-2F /20&21 ,22,23,26,27 1x9000CFM /6RD CC/2RDHC19TR /70mm Static /5.5 KW

5

-

-

... More
FM AHU-GFU /06 , FM AHU-3F /42,49,50,51,52 1x10000CFM /6RD CC/2RDHC/21.8TR /70mm Static/5.5 KW

5

-

-

... More
FM AHU-3F /29 1x15000CFM //6RD CC/2RDHC/33.8TR /70mm Static /11 KW

1

-

-

... More
FM AHU-3F /32&33 2x16000CFM /6RD CC/2RDHC/28.95TR /70mm Static/11 KW

2

-

-

... More
FM AHU-1F /11 , FM AHU-3F /47 1x18000CFM //6RD CC/2RDHC/37.4TR /70mm Static/11 KW

2

-

-

... More
100% F.A AIR HANDLING UNITS Supply installation testing and commissioning of Floor Mounted Horizontal type ,Double Decker, Double Skin Air Handling unit WITH HIGH EFFICIENCY HEAT RECOVERY WHEEL & UV tube in 43±2 mm thick puf insulation complete with thremal break profile Outer skin wil be 0.8mm prepalsticized GS sheet. Inner skin 0.8mm thick plain GS and cooling coil onwared Prepasticized with flowing section. (i)Pre filter & fine filter on common frame with pre filter of EU-4 rating & Fine filter with EU-6 filter rating. with Inclined tube manometer and accessories (ii)HRW section with Suitable model for HRW (iii)Chilled water Coil section with coil (iv)Hot water Coil section with coil (v)Dehumidfier with Pre cooling Unit 12TR with valves & required arrrangement. . PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

2

-

-

... More
FM AHU-GFU/03 , 3F/37 , 3F-39 FOR SPECTIC OT AND OT 7 & 5 (4000CFM /10.6TR/ 7.5 HP Supply air backward curve , 8 Row CC, 2 Row HC 125 mm Static Pressure for Supply Fan ,3200CFM /3HP Ex.air backward curve ,70 mm Static Pressure for Exhaust fan )

2

-

-

... More
FM AHU-1FU/14 ,3F/34,3F/35,3F/36 4500CFM /10.6TR/ 7.5 HP Supply air backward curve , 8 Row CC, 2 Row HC 125 mm Static Pressure for Supply Fan ,5600CFM /5HP Ex.air backward curve ,70 mm Static Pressure for Exhaust fan )

4

-

-

... More
AIR HANDLING UNITS ( FOR ISO 8, RECIRCULATION AHU , HEPA FILTER IN DISCHARGE PLENUM ) Supply installation testing and commissioning of Horizontal type Double Skin Air Handling Units in 43±2 mm thick puf insulation complete with thremal break profile Outer skin wil be 0.8mm prepalsticized GS sheet. Inner skin 0.8mm thick plain GS and cooling coil onwared Prepasticized with flowing section. PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

2

-

-

... More
FM AHU-3F-39 1x4000CFM/8RD CC/2RDHC/7.0TR /125MM Static /3.7 KW

1

-

-

... More
FAN COIL UNITS Supply, Installation, Testing and Commissioning of Ceiling suspended ductable fan coil units complete with casing, filter box complete with synthetic fiber filters, cooling coil, fans, 3-speed motors, extended drain pan, flexible connection, drain pipe connection complete with following equipment as per tender drawings, and specifications. (a) Copper flexible connection complete with Set of ball valves with and without strainer. (b) Air tight, Water & Fire proof single layered canvass cloth complete with flanges in both side for connection to duct collar and fan coil unit. (c)Electrical and control cabling for proper connection from the 15 amps outlet to connector box, valve etc. as well as connection of thermostat. (d)Controls for FCUs comprising of thermostat, Two way motorised control valve, balancing valve control wiring. (e) Supply and Return air grille & necessary Ducting for Connection Fan coil units 1.5 TR FCU / 1020 CMH / 600CFM / 4RD

17

-

-

... More
2.0 TR FCU / 1360 CMH / 800CFM / 4RD

20

-

-

... More
CHILLED WATER TYPE CASSetTE UNITS Supply, Installation, Testing and Commissioning of Ceiling suspended hydronic water chilled casSette units complete with casing, filter box complete with synthetic fiber filters, cooling coil, fans, 3-speed motors, extended drain pan, flexible connection, drain pipe connection complete.Copper flexible connection complete with Set of ball valves with and without strainer.Electrical and control cabling for proper connection from the 15 amps outlet to connector box, valve etc. as well as connection of thermostat.Controls for units comprising of thermostat, Two way motorised control valve, balancing valve, control wiring. CASSetTE UNITS 1.5 TR/600 CFM/18000/BTU/Hr CasSette Units

18

-

-

... More
2 TR/800 CFM/24000/BTU/Hr CasSette Units

28

-

-

... More
2.5 TR/1000 CFM/30000/BTU/Hr CasSette Units

14

-

-

... More
3.0 TR/1200 CFM/36000/BTU/Hr CasSette Units

6

-

-

... More
3.5 TR/1400 CFM/42000/BTU/Hr CasSette Units

3

-

-

... More
Supplying of approved make split type Air Conditioner unit with cooling unit and condensing unit with standard length of upto 3 metre of copper piping with insulation etc complete as required: (27.3.2)1.5 ton split type capacity 4500 kcal / hr (3 star).

5

-

-

... More
2.0 ton split type capacity 6000 kcal / hr (3 star).

5

-

-

... More
Condensate Drain Piping:- Supplying, laying, fixing, testing & commissioning of GI class B pipes complete with all necessary fittings such as elbows, tees, reducers etc and supports such as clamps etc. complete as per specifications & drawings. Providing and fixing of MS C class pipes insulation with 13/19 mm thick Elastomeric Nitrile Rubber Foam, with adhesive, tapes etc.as per specifications and drawings. 32 mm dia MS pipes (B class, for condensate drain)

500

-

-

... More
Supply, installation, testing and commissioning of ultrasonic type Humidification package with Humidistat with all necessary control cabling as required as per standard specification & of following capacities: 3LPH

6

-

-

6

-

-

... More
Supply, installation, testing and commissioning of duct mounted air purification system/ cell based on advanced oxidation technology with broad spectrum UV lamp (100-380 NM) enhanced on the quad metallic compound target/ hydrated catalytic matrix cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial, viral and spores contamination and VoC’ and odors. The UV lamp must be enclosed in a poly casing to prevent mercury at all cost. PHIO 1520

15

-

-

... More
PHIO 510

1

-

-

... More
PHIO 25

7

-

-

... More
PART B MECHANICAL VENTILATION SYSTEM PROPELLAR FANS FOR TOILET VENTILATION Supply, installation, testing and commissioning of Propeller Type Heavy Duty Exhaust Fan complete with bird screen,gravity louvers, metal clad MCB & starter,5m length copper cable, earthing wire all compete as required, suitable for single phase, 230 volts, 50Hz AC. supply of following capacities: (a)Size:300 mm dia, RPM: 900

30

-

-

... More
INLINE FANS FOR TOILET VENTILATION Supply, installation, testing and commissioning of ceiling suspended Inline fans (Rectangular/Round casing) complete with bird screen, rain guard, metal clad MCB & starter ,5m length copper cable, earthing wire all compete as required of following capacities as per specification and shop drawing mentioned. Note:- All inline fans should be single phase supply with 3 speed regulators etc. 150cfm ,15mm St.Pr.

3

-

-

... More
200cfm ,15mm St.Pr.

3

-

-

... More
250cfm ,15mm St.Pr.

7

-

-

... More
300cfm ,15mm St.Pr.

14

-

-

... More
350cfm ,15mm St.Pr.

7

-

-

... More
400cfm ,15mm St.Pr.

7

-

-

... More
450cfm ,20mm St.Pr.

2

-

-

... More
500cfm ,20mm St.Pr.

7

-

-

... More
550cfm ,20mm St.Pr.

4

-

-

... More
600cfm ,20mm St.Pr.

5

-

-

... More
650cfm ,25mm St.Pr.

3

-

-

... More
700cfm ,25mm St.Pr.

3

-

-

... More
750cfm ,25mm St.Pr.

3

-

-

... More
800cfm ,25mm St.Pr.

3

-

-

... More
850cfm ,25mm St.Pr.

2

-

-

... More
900cfm ,25mm St.Pr.

8

-

-

... More
950cfm ,25mm St.Pr.

3

-

-

... More
1000cfm ,25mm St.Pr.

2

-

-

... More
1200cfm ,25mm St.Pr.

2

-

-

... More
1300cfm ,25mm St.Pr.

3

-

-

... More
2000cfm ,25mm St.Pr.

1

-

-

... More
FRESH AIR FAN AXIAL FLOW FANS WIH SOUND ATTENUATOR Supply ,installation ,testing & commissioning of UL Listed ceiling mounted Axial flow fans with sound attenuator (Fire Rated) AMCA Certified for air & sound performance, with adjustable pitch blade & angle , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 6pole, three Phase, A.C supply class H insulation with support, Phase& Motor rated Value IP55 . Motor shall be Thermally Rated for 250degC for 2 hours & direct driven for smoke extraction fans. Note : - Outlet Velocity not to exced 14.0 MPS FRESH AIR FAN FOR NORMAL AS WELL AS FIRE MODE VENTILATION SYSTEM PARKING AREA Air Qty. 12500 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

2

-

-

... More
ELECTRICAL ROOM Air Qty.- 10000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
FRESH IN CASE OF FIRE MODE VENTILATION SYSTEM Air Qty.- 2000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 1.1 Kw.

2

-

-

... More
Air Qty.-25000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 1.1 Kw.

1

-

-

... More
Air Qty.- 2700 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 1.1 Kw.

1

-

-

... More
Air Qty.-4000 CFM (Audotorium),Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

2

-

-

... More
Air Qty. - 4500 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

3

-

-

... More
Air Qty.- 5500 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

1

-

-

... More
Air Qty. - 6000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
Air Qty. - 7000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
Air Qty.- 7600 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
Air Qty.- 8000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
Air Qty. -12000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

2

-

-

... More
Air Qty. - 13000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

1

-

-

... More
Air Qty. -13500 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

4

-

-

... More
Air Qty. - 14000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

3

-

-

... More
Air Qty.- 16000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

1

-

-

... More
Air Qty. - 21000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 11.0 Kw.

2

-

-

... More
EXHAUST AIR FAN FOR LOWER GROUND FLOOR LEVEL AXIAL FLOW FANS WIH SOUND ATTENUATOR Supply ,installation ,testing & commissioning of UL listed ceiling mounted Axial flow fans with sound attenuator (Fire Rated) AMCA Certified, with adjustable pitch blade & angle , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 6pole, three Phase, A.C supply class H insulation with support, Phase& Motor rated Value IP55 . Motor shall be Thermally Rated for 250degC for 2 hours & direct driven for smoke extraction fans. Exhuast air in case of Normal as well as Fire mode Ventilation GROUND FLOOR (LOWER LEVEL ) PARKING AREA Air Qty.-12500 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

4

-

-

... More
ELECTRICAL ROOM Air Qty. - 10000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

1

-

-

... More
EXHAUST IN CASE OF FIRE MODE VENTILATION SYSTEM Air Qty. - 2000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 1.1 Kw.

2

-

-

... More
Air Qty. -25000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 1.1 Kw.

1

-

-

... More
Air Qty.-2700 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 1.1 Kw.

1

-

-

... More
Air Qty.- 4000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

2

-

-

... More
Air Qty. - 4500 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

3

-

-

... More
Air Qty. - 5500 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

1

-

-

... More
Air Qty. - 6000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
Air Qty. -7000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
Air Qty.- 7600 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
Air Qty. - 8000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
Air Qty. 12000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

2

-

-

... More
Air Qty. -13000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

1

-

-

... More
Air Qty. - 13500 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

4

-

-

... More
Air Qty. - 14000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

3

-

-

... More
Air Qty.- 16000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 5.5 Kw.

1

-

-

... More
Air Qty. - 21000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 11.0 Kw.

1

-

-

... More
FRESH IN NORMAL MODE VENTILATION SYSTEM TUBE AXIAL FLOW FANS Supply ,installation ,testing & commissioning of UL Listed ceiling mounted Tube Axial flow fans (AMCA Certified) with adjustable pitch blade & angle ,MS casing, cast aluminium alloy impeller completewithTEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4pole,three Phase, A.C supply class F insulation with support & Motor rated Value IP55, mountings and flexible connection etc. & of following capacity with the Approx. Motor HP as given below ( to be supported with Documentery Avdience at the time of Technical Bid.). Note : - Outlet Velocity not to exced 14.0 MPS Fresh Air Fans in case of Normal as well as Fire mode Ventilation LAUNDRY Air Qty.-7500 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
TUBE AXIAL FLOW FANS Supply ,installation ,testing & commissioning of UL listed ceiling mounted Tube Axial flow fans (AMCA Certified) with adjustable pitch blade & angle ,MS casing, cast aluminium alloy impeller completewithTEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4pole,three Phase, A.C supply class F insulation with support & Motor rated Value IP55, mountings and flexible connection etc. & of following capacity. Note : - Outlet Velocity not to exced 14.0 MPS Exhaust air in case of normal mode ventilation system LAUNDRY Air Qty.- 9000 CFM,Static Pressure 30 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7 Kw.

1

-

-

... More
SISW FAN FOR EXHUAST IN NORMAL MODE VENTILATION Supply ,installation ,testing & commissioning of ceiling mounted SISW fans (AMCA Certified) with adjustable pitch blade & angle ,MS casing, cast aluminium alloy impeller completewithTEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4pole,three Phase, A.C supply class Finsulation with support & Motor rated Value IP55, mountings and flexible connection etc. & of following capacity. Note : - Outlet Velocity not to exced 14.0 MPS Exhaust air in case of normal mode ventilation system SPARE ROOM Air Qty. - 3250 CFM,Static Pressure 25 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

2

-

-

... More
FOR TOILET VENTILATION SYSTEM Air Qty. - 3500 CFM(1W+S),Static Pressure 25 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

2

-

-

... More
Air Qty. -4000 CFM(1W+S),Static Pressure 25 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

2

-

-

... More
Air Qty. - 5000 CFM(1W+S)),Static Pressure 25 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

2

-

-

... More
Air Qty. -10000 CFM(1W+S),Static Pressure 25 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 2.2 Kw.

2

-

-

... More
Air Qty.-15000 CFM(1W+S),Static Pressure 25 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 7.7Kw.

2

-

-

... More
FRESH AIR FOR PRESSURIZATION TUBE AXIAL FLOW FANS Supply ,installation ,testing & commissioning of UL listed ceiling mounted Tube Axial flow fans (AMCA Certified) with adjustable pitch blade & angle ,MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4pole,three Phase, A.C supply class F insulation with support & Motor rated Value IP55, mountings and flexible connection etc. & of following capacity. with the Approx. Motor HP as given below ( to be supported with Documentery Avdience at the time of Technical Bid.) Note : - Outlet Velocity not to exced 14.0 MPS LIFTWELL PRESSURIZATION Fan Capacity - 6500 CFM,Static Pressure 20 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7Kw.Noise level - Not to exceed 90 db at 3 meter distance

7

-

-

... More
Fan Capacity - 5500 CFM,Static Pressure 20 mm Wg,Motor Pole 4/6/8 Pole,Motor rating- Not exceeding 3.7Kw.Noise level - Not to exceed 90 db at 3 meter distance

1

-

-

... More
PART C AIR DISTRIBUTION SYSTEM DUCTING WORK Supply, Installation, Balancing & Commissioning of lead free factory fabricated GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, sealant ,elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. All support shall be gripple based. (28.16.1) 24 G (0.63 mm)

3500

-

-

... More
22 G (0.80 mm)

1200

-

-

... More
20 G (1.0 mm)

646

-

-

... More
18 G (1.25 mm)

320

-

-

... More
Ductting For OT with Gripple Support Factory Fabricated Boxed Ducts made on CNC machine from CFC Free PUF/PIR (Polyurethane Foam/Polyisocyanurate Foam) Panel/ Board for External/Exposed use meeting specifications as mentioned in detailed specs. Majorly, The Thickness of board shall be 30mm, Density of foam shall not be less than 50 kg/m³, Thermal Conductivity not more than 0.020W/m.K. at 10 degC mean temp,should be able to withstand -35 Deg C to 110 Deg C, base material shall be Impermeable to moisture and Insoluble, Panel compressive strength should be minimum 220 Kpa as per ASTM 1621 and Flexural Strength of 1170 KPa as per ASTM C203. It should be a certified Anti Rodant type material. It should be able to withstand 1750 pa pressure without any deformation and change in insulation, chemical or physical characteristics. The Aluminium Foil shall be PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

847

-

-

... More
Main Box Type Duct Damper Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room. (28.19.1)Damper

29

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. .for OT only

7

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. (28.25.1)Fire damper

25

-

-

... More
Actuator

57

-

-

... More
Supply, installation, testing and commissioning of 50 micron powder coated Aluminium collar volume control dampers with key operated of black painted in supply & Return air registers / terminals.

165

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

92

-

-

... More
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

60

-

-

... More
Supplying & fixing of 50 micron powder coated Fresh air intake louvers bird screen type (Aluminium extruded only) as per specification and sizes will be as per shop drawing mentioned.

50

-

-

... More
Terminal Hepa Modules to Accomadate HEPA Filter Supply, installation, testing and commissioning of HEPA Filter Modules made out of 1.2mm GI Powder coated construction complete with Floor operated Bewel Gear Damper, Filter fixing Raaangement along with DOP test port .Filter fixing frames as standard. Modules to include SS 304 1.2mm perforated grille with SS CSK Screw to fit fluah with Module . To accomadate -- 2400 x 1800 x 450 Filter

70

-

-

... More
To accomadate -- -915 x 610 x 75mm Filter

30

-

-

... More
Supply, installation, testing and commissioning of SS-304 1.0 mm thick. Perforated Grille for supply and return air in Non & Classiffied Areas. Sizes will be as per the drawing HEPA Filter

55

-

-

... More
HEPA Filter ( High efficiency particulate air) designed to remove particles down to 0.3 Microns from air streams with an efficiency of 99.97 %. The filter matrix comprises glass fiber media with machine pleated specially treated aluminium seperators with DOP test. 610 mm x610mm x300mm (1000CFM)

70

-

-

... More
610 mm x610mm x150mm (500CFM)

30

-

-

... More
PART D LOW SIDE PIPING WORK Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold Setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. C class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

30

-

-

... More
100mm dia pipe (50mm thick Insulation)

150

-

-

... More
80mm dia pipe (50mm thick Insulation)

420

-

-

... More
65mm dia pipe (50mm thick Insulation)

520

-

-

... More
50mm dia pipe (50mm thick Insulation)

420

-

-

... More
40mm dia pipe (50mm thick Insulation)

180

-

-

... More
32mm dia pipe (50mm thick Insulation)

175

-

-

... More
25mm dia pipe (50mm thick Insulation)

850

-

-

... More
Valves With Insulation Supplying, fixing, testing and commissioning of following size BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water line duly insulated to the same specifications as the connected piping and adequately supported as per specifications. (28.7.5) 80mm Dia.

14

-

-

... More
65 mm Dia

24

-

-

... More
50 mm Dia

48

-

-

... More
40 mm Dia

42

-

-

... More
Globe Valve/Control Valve 32mm Dia

30

-

-

... More
Supplying, fixing, testing and commissioning of following size BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water/ hot water line duly insulated to the same specifications as the connected piping and adequately supported as per specifications. (28.8.8) 40 mm Dia

21

-

-

... More
80 mm Dia

7

-

-

... More
Supplying, fixing, testing and commissioning of following size Y-STRAINER of Ductile CI Body flanged ends with stainless steel strainer for for chilled water/ hot water line duly insulated to the same specifications as the connected piping and adequately supported as per specifications. (28.10.8) 40 mm Dia

21

-

-

... More
80 mm Dia

7

-

-

... More
SITC of 2 way ball type modulating control valve with internal threaded (BSPP) end connections, Kvs 10 m3/h, equal percentage flow characterstic, PN16, body Cast Brass with stainless steel ball. Non spring return rotatory type modulating actuator, torque 10 Nm, close-off pressure 1400 kPa, power supply 24V AC/DC, control signal 2 (0)-10 V DC, IP54 with Voltage Feedback Signal & temparature controller with desplay 25 mm Dia

15

-

-

... More
Solenoid Valve with actuator & Snap acting Humidstat 32MM Dia

14

-

-

... More
Providing & Fixing in position the mercury in glass industrial type thermometer complete as required.

144

-

-

... More
Providing & Fixing in position the industrial type Common Pressure Gauge with ball Valves complete as required.

72

-

-

... More
Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as required. (26.7.7) 25 mm Dia

72

-

-

... More
Supply, Installation, Testing, & Commissioning of Automatic air vent with ball valve in brass construction complete with nipples, union etc. as required at all high points in the pipe lines. The valve shall be such as to have non-return valve as integral part of the vent. (3(f) i)10 mm dia auto air vent valve

144

-

-

... More
PART E INSULATION WORK. Supply and fixing of fire retardent closed cell chemically crosslinked polyethylene foam insulation with with factory applied aluminium foils.Thermal conductivity of the materials shall not exceed 0.035 w/mk at an average temperature of 40 deg celcius. 9 mm thick Closed Cell Cross Linked Polythylene( XLPE) Foam with Factory Laminated Al PE Foil for Return Air Duct

800

-

-

... More
13 mm thick Closed Cell Cross Linked Polythylene( XLPE) Foam with Factory Laminated Al PE Foil for Supply Air Duct

5500

-

-

... More
ROOF INSULATION Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class O) insulation on existing duct after applying two coats of cold Setting adhesive (CPR X compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. (28.28.2) 25 mm thick Class O Nitrile Rubber Insulation with GC cloth

6564

-

-

... More
Condensate Drain Piping: - Supplying, laying, fixing, testing & commissioning of GI class B pipes complete with all necessary fittings such as elbows, tees, reducers etc and supports such as clamps etc. complete as per specifications & drawings. Providing and fixing of MS C class pipes insulation with 13/19 mm thick Elastomeric Nitrile Rubber Foam, with adhesive, tapes etc.as per specifications and drawings. 40 mm dia MS pipes (B class, for condensate drain)

1200

-

-

... More
32 mm dia MS pipes (B class, for condensate drain)

700

-

-

... More
25 mm dia MS pipes (B class, for condensate drain)

1050

-

-

... More
PART F ELECTRICAL WORK. CUBICAL PANEL BOARD FOR ALL AHUS Supply, Installation, Testing and commissioning of CPRI Approved wall mounted panels near the each AHUs constructed out of 2mm thick CRCA sheet duly powder coated as per specifications. The panel shall have hinged door with on-off interlocks. The panel shall be complete with incoming MPCB/MCCB, suitable bus bars of aluminum construction, bus links complete with Star delta /DOL starter with hands, off, automatic mode, selection switch, ammeter for each motor, timer, Auto Manual switch, remote start/stop contacts, earthing connector etc.,as required complete as per specifications. The AC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto / manual mode selector switch in the outgoing feeder for AHU Fan etc . PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

10

-

-

... More
For AHU ( 5.0 HP Fan Motor) 3x (6-10)A TP MPCB with 5HP DOL starter, overload relay inbuilt single phase prvention, start/stop push buttons, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA

12

-

-

... More
For AHU ( 7.5 HP Fan Motor) & Plant Room Axial Flow Fans (11-16)A TP MPCB with 2x 7.5HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, digital ammeter (0- 30A) with CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA (ICU=ICS)

20

-

-

... More
For AHU ( 10 HP Fan Motor) (14-20)A TP MPCB with 10.0 HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, digital ammeter (0- 30A) with CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA (ICU=ICS)

2

-

-

... More
For AHU ( 15 HP Fan Motor) (24-32)A TP MPCB with 15.0 HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, digital ammeter (0- 50A) with CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA (ICU=ICS)

6

-

-

... More
SUB - PANELS FOR AIR HANDLING UNITS OF OT'S Supply, installation, testing and commissioning of Cubical type sectinalised/campartmentalised floor/wall standing switchboard by CPRI approved firms complete with 4 strip, suitable capacity alumunium bus-bar electrolytic grade E-91, cable alley, switchgears suitable for AC-23 duty & of following capacity as per specification given in the tender THIRD FLOOR AHU FOR OT-01 TO 07 INCOMER 1 No. 63 A TPN, MCCB with Thermal Magnetic release with Overload, Short Circuit, with 96 mm (0 - 60 A) digital ammeter with 3 CT and selector switch, 96 mm (0 - 500 V) digital Voltmeter with selector switch, phase indication light with control MCB, . MCCB Shall be of 25KA (ICU=ICS) Set 01 OUTGOING (i)For AHU Supply Fan Motor 7.0HP#5-10A TPN MPCB with 5.0HP DOL starter, overload relay in built PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

11

-

-

... More
FOR AXIAL FLOW FANS For AHU ( 2.0 HP Fan Motor) (3-5)A TP MPCB with 2HP DOL starter, overload relay inbuilt single phase prvention, start/stop push buttons, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA

8

-

-

... More
For AHU ( 3.0 HP Fan Motor) (4-7.5)A TP MPCB with 3HP DOL starter, overload relay inbuilt single phase prvention, start/stop push buttons, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA

21

-

-

... More
For AHU ( 5.0 HP Fan Motor) 3x (6-10)A TP MPCB with 2x 5HP DOL starter, overload relay inbuilt single phase prvention, start/stop push buttons, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA

20

-

-

... More
For AHU ( 7.5 HP Fan Motor) & Plant Room Axial Flow Fans (11-16)A TP MPCB with 7.5HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, digital ammeter (0- 30A) with CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA (ICU=ICS) Set 01

27

-

-

... More
For AHU ( 10 HP Fan Motor) (14-20)A TP MPCB with 10.0 HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, digital ammeter (0- 30A) with CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA (ICU=ICS)

4

-

-

... More
For AHU ( 15 HP Fan Motor) (24-32)A TP MPCB with 15.0 HP Stardelta starter, overload relay inbuilt single phase prevention, start/stop push buttons, digital ammeter (0- 50A) with CT, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA (ICU=ICS)

2

-

-

... More
CUBICAL PANEL BOARD FOR AIR HANDLING UNITS FOR AUDITORIUM Design, manufacture, supply, installation, testing and commissioning of the following 2 mm thick sheet steel enclosed separate compartment for each feeder, front operated, indoor type LT motor control panel, dust and vermin proof, /hinged and lockable doors, complete with internal wiring, colour coding with ferrules, cable glands plates, bonding to earth and painting etc as required. INCOMER (i)100Amp TPN MCCB with overload short ckt earth fault protection Release with 144 mm ( 0 -100A) ammeter with 3CT & selector switch 144mm( 0 - 500V ) Voltmeter with selector switch phase indication light with protection fuse, on / off / trip indicating light. MCCB shall be of 25 KA Set - 01 Sections of 100Amps TPN bus bar chamber of suitable lengths with Aluminium bus bars. PLEASE REFFER THE ATTACHED NIT SCHEDULE UNDER ATTACHMENT SECTION FOR DETAILED DESCRIPTION

1

-

-

... More
Supply,Installation , Testing Commissioning of Isolator Box with MCB/MCCB

150

-

-

... More
BMS System Design,Supply,Installation,Testing & Handing over of the Building Management system (BMS) and allied system as per specifications as below. SITC of central control stations consisting of IBM Pentium machineconsisting of (a) 3GHz Processor (b)3 GB RAM,120 GB hard Disc.(c)3.5 Inch Disc Drive,DVD writer,Compatible CDROM,Window XP and shall have registerd MS Office installed as per specification

1

-

-

... More
21 Inch Flate Screen,1200 2,800,256 Colours

1

-

-

... More
Black & White A 4 Laser Printer (Alarm and Report)

1

-

-

1

-

-

... More
Key-Board

1

-

-

... More
BMS System Software:- WEB Based graphical software meeting the requirement in the given I/O summary and techical specification including configuration and facilling to create /provide the graphic mapping for all I/O summary points, Animate the graphics ,Navigation between pages , Display of Logs , Changing the time zones , POP Up Alarms ,Configurable passaward protection for building management system as per specification. Software shall be able to communicate with I/O works , BACNET,MODBUS Devices simultaneously with unlimited user and point liecence capacity. Same Software can be utilised as programming /Commissioning Software of DDC,NAC etc. Note:-All required software with original liecence competent with(BMS software)

1

-

-

... More
WEB Based Router/Network Area Controller Interfacing the DDC Controllers and integrator for the system with PC.It has Capacity to store trends and programe backup.It should be BTL & UL Listed.

1

-

-

... More
WEB Based Integrator for interfacing MODBUS RTU Unit, BACNET IP/MSTP, open protocol software integration for following:-(a)For 3 Nos. Chiller system interface on BACNET IP/MODBUS RTU (software) (b)For 4 Nos. Lifts interface on MODBUS ( c) For VFDs on MODBUS (d) For FAS on Bacnet/ IP or MODBUS-1000 I/O Points (e) For Diesel Generator- 2 Nos on MODBUS. (f) For Energy meters-25 Nos on MODBUS. (g)For UPS-1 No.on MODBUS. (h) For HT/LT Panel- 5 Nos. On MODBUS Note : All Electrical panel for HVAC system shall be BMS Compatible

1

-

-

... More
Automation station /DDC Controller with I/O module etc., The controllers shal be 32 bit microprocessor based standalone and net workable type with real time clock. The DOCs shall be capable of peer to peer communication without help of system interface controller or PC with locable MS mounting cabinets duly power coated connector strip, internal wiring and space to house controller & relays, connector strip current trasnsformer, MCB, internal wiring. (Contractor shall confirm his I/O provision w.r.t requirement on basis of data point).

1

-

-

... More
Hand Held portable operator terminal. Note :- Provision of integration with any BMS system conforming to ASHRAE bacnet/IP or MODBUS IP. OPC shall be provided by respective equipment manufacture.

1

-

-

... More
Sensors and field devices supply, installation, testing, commissioning of necessary input sensor transmitters/transducers comprising the following : Duct static Pressure sensor.

52

-

-

... More
Immersion Temp Sensor for CHW line.

16

-

-

... More
Outside Temp & Humidity Sensor.

4

-

-

... More
Water Level Switches for Water Tanks.

12

-

-

... More
Differental Switches for Water Pumps.

42

-

-

... More
DP Switches Air for Monitoring Blower, Fan & Filter Status.

100

-

-

... More
Duct Type Temp Sensor.

52

-

-

... More
Electromagnetic Type Water Flow Meter - 350 mm.

2

-

-

... More
Outdoor Duty CO2 Sensor.

2

-

-

... More
Water Flow Switch.

16

-

-

... More
Pressure sensor for Water Header Range (0-5 Kg/cm2)

4

-

-

... More
Room Mounted CO2 Sensor.

52

-

-

... More
Flame Proof Level Switch.

8

-

-

... More
Current Relay.

16

-

-

... More
DG Voltage Transducer.

4

-

-

... More
PH Transmitter.

2

-

-

... More
TDS Transmitter.

2

-

-

... More
Outdoor Lux Sensor.

8

-

-

... More
Conduiting, Wiring and cabling Supplying, installation, testing, commissioning of following cables : Supplying, installing, testing, commissioning of singal cables.

4934

-

-

... More
Supplying, installing, testing, commissioning of communication cables.

3540

-

-

... More
Supplying, installing, testing and commissioning of MS conduits of 25 mm dia complete with all accessories.

6130

-

-

... More
Supplying, installing, testing and commissioning of Lan cable in 25 mm dia MS conduit (complete with all RM accessories) as per manufacturers recommendation.

1200

-

-

... More
Supply, installation, testing and commissioning of extruded aluminium powder coated supply / return air grilles of approved shade and make Extruded aluminium construction, single louvered, powder coated with GI volume control damper.

14.5

-

-

... More
Extruded aluminium construction, single louvered, powder coated without volume control damper for return / exhaust air.

14.5

-

-

... More
Supply, installation, testing and commissioning of extruded aluminium powder coated fixed bar linear grills of approved shade and make. 150 mm wide

565

-

-

... More
Supply, installation, testing and commissioning of Aluminium volume control dampers for ducts (OTs only)

11

-

-

... More
PART - A HIGH SIDE (VRF EQUIPMENTS ) Variable Refrigerant Flow Air-conditioning System to be selected on raigarh actaul condition ,No ARI to be accepted The prices are to be quoted in the below mentioned form & shall include the supply, installation,testing & commissioning at site of all the equipments, ancillary materials as specified and all such items what so ever required to fulfill the intent and purpose as laid down in the specifications and / or drawings . Supply, Instalaltion, testing and commissioning of Variable Refrigerant Flow modular type airconditioning system Invertor Controlled with stepless modulation complete with indoorand outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications and having following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.Supply of Outdoor Unit with bluefin coating Supply Instalaltion, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll compressors with both inverter type compressors special heat exchanger, low noise condenser fan ,auto check function for connection error, auto address Setting and capacity as mentioned below. 8HP Heat Pump Type (Cooling & Heating )

1

-

-

... More
10HP Heat Pump Type (Cooling & Heating )

2

-

-

... More
12HP Heat Pump Type (Cooling & Heating )

4

-

-

... More
14HP Heat Pump Type (Cooling & Heating )

1

-

-

... More
18HP Heat Pump Type (Cooling & Heating )

3

-

-

... More
20HP Heat Pump Type (Cooling & Heating )

1

-

-

... More
24HP Heat Pump Type (Cooling & Heating )

1

-

-

... More
26HP Heat Pump Type (Cooling & Heating )

2

-

-

... More
28HP Heat Pump Type (Cooling & Heating )

1

-

-

... More
30HP Heat Pump Type (Cooling & Heating )

1

-

-

... More
32HP Heat Pump Type (Cooling & Heating )

1

-

-

... More
34HP Heat Pump Type (Cooling & Heating )

1

-

-

... More
40HP Heat Pump Type (Cooling & Heating )

1

-

-

... More
48HP Heat Pump Type (Cooling & Heating )

2

-

-

... More
Supply of Indoor Units Supply Installation, testing and commissioning of Indoor units address Setting and capacity as mentioned below. multispeed motor, coil section with DX coil, outer cabinet, drain pan, drain pump, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for casSettes etc. of various capacities as per specifications and drawings A Ceilling Suspended 4 way CasSette Unit Ceiling Suspended CasSette Units : -(i) 1.65 TR / 565 CFM

7

-

-

... More
(ii) 1.65 TR / 565 CFM

4

-

-

... More
(iii)1.8 TR / 565 CFM

6

-

-

... More
(iv) 2.0 TR / 671 CFM

46

-

-

... More
(v) 2.6 TR / 742 CFM

19

-

-

... More
(vi) 3.18 TR / 1130 CFM

24

-

-

... More
(vii) 4.0 TR / 1165 CFM

9

-

-

... More
B HI WALL UNIT 2TR Hi Wall Unit

8

-

-

... More
Supply Instalaltion, testing and commissioning of Imported Y-joints.

101

-

-

... More
Supply Instalaltion, testing and commissioning of self diagnostic type remote controllers. CordlessType

123

-

-

... More
Supply Instalaltion, testing and commissioning of Main Intelligent central controller system Touch Screen suitable for above indoor units to operate, monitor, on/off, temperature Setting etc.

1

-

-

... More
PART - B LOW SIDE. ( REF. PIPING ,DUCTING ,GRILLE DIFFUSER ETC) DOUBLE SKINNED AIR HANDLING UNITS Supply, Installation, testing and commissioning of double skin airhandling units floor mounted/Ceiling Suspended type AHU complete with fan, fan motor, drive, DX cooling coil, HDPE filters, Expansion device, communication kit, canvass connection and remote control etc complete with accessories for AHU kit ,Expansion Device & control box. (a)CS AHU-07 & 08 - 1500 CFM/ 6RD / 50mm static

2

-

-

... More
(b)CS AHU-11 - 2500 CFM/ 6RD / 50mm static

1

-

-

... More
(c)CS AHU-10 - 3000 CFM/ 6RD / 50mm static

3

-

-

... More
(d)CS AHU-06 & 09 - 4500 CFM/ 6RD / 50mm static

2

-

-

... More
(e)FM AHU-05 - 6000 CFM / 6RD / 50mm static

1

-

-

... More
(f)FM AHU-02 & 01 - 7000 CFM / 6RD / 50mm static

2

-

-

... More
Refrigerant Piping Supply & fixing of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. All piping inside the room shall be properly supported on MS Slotted trays and all external piping shall run in covered slotted tray (i). 41.1 mm O.D. (insulation - 19 mm thick)

40

-

-

... More
(ii)34.9 mm O.D. (insulation - 19 mm thick)

13

-

-

... More
(iii)28.6 mm O.D. (insulation – 19 mm thick)

360

-

-

... More
(iv)22.2 mm O.D. (insulation – 19 mm thick)

123

-

-

... More
(v)19.1 mm O.D. (insulation – 13 mm thick)

170

-

-

... More
(vi)15.9 mm O.D. (insulation – 13 mm thick)

1235

-

-

... More
(vii)12.7mm O.D. (insulation – 13 mm thick)

101

-

-

... More
(viii)9.5 mm O.D. (insulation – 13 mm thick)

1233

-

-

... More
Drain Piping Condensate Drain Piping: - Supplying, laying, fixing, testing & commissioning of GI class B pipes complete with all necessary fittings such as elbows, tees, reducers etc and supports such as clamps etc. complete as per specifications & drawings. Providing and fixing of MS C class pipes insulation with 13/19 mm thick Elastomeric Nitrile Rubber Foam, with adhesive, tapes etc.as per specifications and drawings. 40 mm dia MS pipes (B class, for condensate drain)

100

-

-

... More
32 mm dia MS pipes (B class, for condensate drain)

123

-

-

... More
25 mm dia MS pipes (B class, for condensate drain)

650

-

-

... More
GSS Ducting Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (28.16.1)Thickness 0.63 mm sheet (24 Gauge)

1057

-

-

... More
Thickness 0.80 mm sheet (22 Gauge)

590

-

-

... More
Thickness 1.00 mm sheet (20 Gauge)

20

-

-

... More
Thickness 1.25 mm sheet ( 18Gauge)

33

-

-

... More
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. (28.24.1) 200 mm dia.

50

-

-

... More
Grille/ Dampers Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

45

-

-

... More
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25 X 50 X50 X 50 X 25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.

488.7

-

-

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. complete

2

-

-

... More
Supply, installation, testing & commissioning of ceiling suspended Propellar fans complete with bird screen, rain guard, metal clad MCB & starter ,5m length copper cable, earthing wire all compete as required of following capacities & as per shop drawing mentioned. (i)300CFM,900RPM

2

-

-

... More
Supply, installation, testing and commissioning ofceiling suspended Inline fans complete with bird screen, rain guard, metal clad MCB & starter ,5m length copper cable, earthing wire all compete as required of following capacities and shop drawing mentioned. FOR TOILET'S EXHAUST (i)500 CFM ,15mm St.Pr.

2

-

-

... More
(ii)1300 CFM ,15mm St.Pr.

4

-

-

... More
TUBE AXIAL FLOW FANS FOR FRESH AIR Supply ,installation,testing &commissioning of UL Listed ceiling mounted Axial flow fans with sound attenuator (Fire Rated) AMCA Certified, with adjustable pitch blade & angle , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 6pole, three Phase, A.C supply class H insulation with support, Phase& Motor rated Value IP55 . Motor shall be Thermally Rated for 250degC for 2 hours & direct driven for smoke extraction fans. Note : - Outlet Velocity not to exced 14.0 MPS In case of Fire mode only Air Qty. -4000 CFM,Static Pressure - 30 mm Wg,Motor Pole- 4/6/8 Pole,Motor - Not exceeding 2.2 Kw.

2

-

-

... More
Air Qty. -7500 CFM(AUDI),Static Pressure - 30 mm Wg,Motor Pole- 4/6/8 Pole.

2

-

-

... More
TUBE AXIAL FLOW FANS FOR EXHAUST AIR Supply ,installation,testing &commissioning of UL Listed ceiling mounted Axial flow fans with sound attenuator (Fire Rated) AMCA Certified, with adjustable pitch blade & angle , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 6pole, three Phase, A.C supply classH insulation with support, Phase& Motor rated Value IP55 . Motor shall be Thermally Rated for 250degC for 2 hours & direct driven for smoke extraction fans. Note : - Outlet Velocity not to exced 14.0 MPS In case of Fire mode only Air Qty.-4000 CFM,Static Pressure - 30 mm Wg,Motor Pole 4/6/8 Pole,Motor Not exceeding 2.2 Kw.

2

-

-

... More
Air Qty.-7600 CFM,Static Pressure - 30 mm Wg,Motor Pole- 4/6/8 Pole,Motor - Not exceeding 2.2 Kw.

2

-

-

... More
PART C ELECTRICAL WORK CUBICAL PANEL BOARD FOR FOLLOWING EQUIPMENTS:- (i)1x8 HP Heat Pump Type (ii)2x10 HP Heat Pump Type (iii)4x12 HP Heat Pump Type (iv)1x14 HP Heat Pump Type (v)3x18 HP Heat Pump Type (vi)1x20 HP Heat Pump Type (vii)1x24 HP Heat Pump Type (viii)2x26 HP Heat Pump Type (ix)1x28HP Heat Pump Type (x)1x30 HP Heat Pump Type (xi)1x32 HP Heat Pump Type (xii)1x34 HP Heat Pump Type (xiii)1x40 HP Heat Pump Type (xiv)2x48 HP Heat Pump Type

1

-

-

... More
Supply, installation, testing and commissioning of Cubical wall mounted type switch board as detailed below & switch gears suitable for AC - 23 duty including making interconnection etc. as required. 1x8 HP Heat Pump Type 32 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

1

-

-

... More
2x10 HP Heat Pump Type 35 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

2

-

-

... More
4x12 HP Heat Pump Type 32 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

4

-

-

... More
1x14 HP Heat Pump Type 40 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

1

-

-

... More
3x18 HP Heat Pump Type 50 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

3

-

-

... More
1x20 HP Heat Pump Type 50 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

1

-

-

... More
1x24 HP Heat Pump Type 63 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

1

-

-

... More
2x26 HP Heat Pump Type 63 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

2

-

-

... More
1x28HP Heat Pump Type 63 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

1

-

-

... More
1x30 HP Heat Pump Type 100 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

1

-

-

... More
1x32 HP Heat Pump Type 100 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

1

-

-

... More
1x34 HP Heat Pump Type 100 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

1

-

-

... More
1x40 HP Heat Pump Type 100 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

1

-

-

... More
2x48 HP Heat Pump Type 100 A TPN MCCB, phase indication lights with control MCB, on / off / trip indication lights with control MCB, digital ammeter with single CT & Voltmeter with selector switch, MCCB shall be of 18KA

2

-

-

... More
FOR AXIAL FLOW FANS For AHU ( 2.0 HP Fan Motor) (3-5)A TP MPCB with 2HP DOL starter, overload relay inbuilt single phase prvention, start/stop push buttons, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA

2

-

-

... More
For AHU ( 5.0 HP Fan Motor) 3x (6-10)A TP MPCB with 2x 5HP DOL starter, overload relay inbuilt single phase prvention, start/stop push buttons, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MPCB Shall be 25 KA

4

-

-

... More
ISOLATORS Providing & fixing weather proof isolator with suitable rating near each outdoor unit, the prices should be inclusive of copper cabling from isolators to outdoor units.

22

-

-

... More
POWER , CONTROL CABLING & EARTHING For VRF outdoor units 1x14 HP 1x20 HP,1x16 HP Supplying, laying, effecting proper connections, testing & commissioning of the following sizes of 1.1 KV - Cross Linked Poly Ethelene armoured aluminum / Copper conductor cables conforming to relevant latest amended Indian Standards including clamping the cables to supports in an approved manner as required complete with all accessories. Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing masonry open duct as required. (5.11.21) 4 x 4 sq. mm

200

-

-

... More
6 x 4 sq. mm

400

-

-

... More
4 x 10 sq. mm

250

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface PVC conduit etc as required. (4.13.15) 6 x 16 sq. mm

250

-

-

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing masonry open duct as required. (17.4.12) 3.5 x 35 sq. mm.

100

-

-

... More
3.5 x 50 sq. mm.

120

-

-

... More
3.5 x 70 sq. mm.

150

-

-

... More
3.5 x 95 sq. mm.

200

-

-

... More
Supplying and laying following sizes one number PVC insulated, PVC sheathed, steel armoured, copper conductor controle cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as required. (17.15.2) 4 x 1.5 sq. mm

1700

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as required.

42

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as required.

400

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.