Nit Schedule For Providing Zonal E/f Work ( O.w.,mow,deposit, S.r. & Ordinary Repair )

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with piano type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of phenolic laminated sheet and M.S. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

34

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 6 amp switch and 3 pin 6 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.4.2 Medium Point

8

-

-

... More
Long Point

4

-

-

... More
Extra Long Point I

5

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 16 amp switch and 6 pin 16 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.5.2 Medium Point

7

-

-

... More
Long Point

6

-

-

... More
Extra Long Point I

4

-

-

... More
Extra Long Point II

3

-

-

... More
Extra Long Point III

2

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point

2

-

-

... More
Medium Point

1

-

-

... More
Long Point

2

-

-

... More
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

3

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.2 Medium Point

2

-

-

... More
Long Point

2

-

-

... More
Extra Long Point I

1

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.3 Long Point

3

-

-

... More
Extra Long Point I

4

-

-

... More
Extra Long Point II

2

-

-

... More
Extra Long Point III

2

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1 3 X 1.5 sq. mm in 20mm conduit

246.8

-

-

... More
3 X 2.5 sq. mm in 20mm conduit

154.2

-

-

... More
6 X 2.5 sq. mm in 25mm conduit

94.6

-

-

... More
9 X 2.5 sq. mm in 32mm conduit

65.2

-

-

... More
12 X 2.5 sq. mm in 32mm conduit

38.3

-

-

... More
3 X 4 sq. mm in 25mm conduit

42

-

-

... More
3 X 6 sq. mm in 25mm conduit

42.8

-

-

... More
6 X 6 sq. mm in 32mm conduit

31

-

-

... More
6 X 10 sq. mm in 40mm conduit

28

-

-

... More
6 X 16 sq. mm in 50mm conduit

9

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp piano type switch, phenolic laminated sheet, suitable size M.S. box etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.1.1 Short Point

36

-

-

... More
Medium Point

63

-

-

... More
Long Point

81

-

-

... More
Extra for providing and fixing light plug point on board in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with piano type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of phenolic laminated sheet and M.S. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

32

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 6 amp switch and 3 pin 6 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.4.2 Medium Point

7

-

-

... More
Long Point

9

-

-

... More
Extra Long Point I

17

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 16 amp switch and 6 pin 16 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.5.2 Medium Point

6

-

-

... More
Long Point

9

-

-

... More
Extra Long Point I

10

-

-

... More
Extra Long Point II

11

-

-

... More
Extra Long Point III

5

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.13.1 3 X 1.5 sq. mm in 20mm conduit

508.6

-

-

... More
3 X 2.5 sq. mm in 20mm conduit

745.6

-

-

... More
6 X 2.5 sq. mm in 25mm conduit

147.8

-

-

... More
9 X 2.5 sq. mm in 32mm conduit

80.4

-

-

... More
12 X 2.5 sq. mm in 32mm conduit

46.9

-

-

... More
3 X 4 sq. mm in 25mm conduit

143.7

-

-

... More
3 X 6 sq. mm in 25mm conduit

171.3

-

-

... More
6 X 6 sq. mm in 32mm conduit

32

-

-

... More
3 X 10 sq. mm in 25mm conduit

19

-

-

... More
6 X 10 sq. mm in 40mm conduit

48

-

-

... More
6 X 16 sq. mm in 50mm conduit

13

-

-

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 2.15.1 20 mm

75

-

-

45

-

-

... More
Supplying and fixing of following sizes PVC casing caping along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5). 2.16.1 20x12 mm

50

-

-

... More
25x16 mm

25

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 3x1.5 sq. mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing 5A piano type switch, phenolic laminated sheet etc. as per specification and IS: 694 (2010) 3.1.1 Short Point

2

-

-

... More
Medium Point

3

-

-

... More
Long Point

1

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing piano type 6 amp switch and 3 pin 6 amps socket outlet, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.3.2 Medium Point

2

-

-

... More
Long Point

2

-

-

... More
Extra Long Point I

1

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface/ concealed, FRLS PVC conduit and providing and fixing piano type 16 amp switch and 6 pin 16 amps socket outlet, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3.4.3 Long Point

2

-

-

... More
Extra Long Point I

3

-

-

... More
Extra Long Point II

1

-

-

... More
Extra Long Point III

2

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.2 2 x 1.5 sq. mm

566.8

-

-

... More
3 x 1.5 sq. mm

504.3

-

-

... More
2 x 2.5 sq. mm

675.4

-

-

... More
3 x 2.5 sq. mm

321.8

-

-

... More
3 x 4 sq. mm

96

-

-

... More
3 x 6 sq. mm

78

-

-

... More
6 x 6 sq. mm

42

-

-

... More
3 x 10 sq. mm

35

-

-

... More
6 x 10 sq. mm

25

-

-

... More
Supplying and fixing of metal box of following sizes (nominal size) in recess with suitable size phenolic laminated sheet cover in front including painting etc as per specification. 4.1.1 75 mm X 75 mm X 60 mm deep

4

-

-

... More
100 mm X 100 mm X 60 mm deep

2

-

-

... More
150 mm X 150 mm X 60 mm deep

3

-

-

... More
180 mm X 100 mm X 60 mm deep

2

-

-

... More
200 mm X 150 mm X 60 mm deep

1

-

-

... More
Supplying and fixing of following sizes wooden switch box made of wooden plank side wall and base including 3mm thick phenolic laminated sheet cover on surface complete as per specification 4.2.1 100mmX100mm

4

-

-

... More
150mmX75mm

3

-

-

... More
150mmX150mm

2

-

-

... More
180mmX100mm

2

-

-

... More
300mmX350mm

1

-

-

... More
Supplying and fixing of following sizes PVC switch box suitable for modular switches with modular base and cover plates on surface complete as per specification 4.3.1 94 mm X 94 mm (1/2 Module)

3

-

-

... More
150mmX94mm (4 Module)

3

-

-

... More
205mmX94mm (6 Module)

2

-

-

... More
8 Module

4

-

-

... More
12 Module

1

-

-

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 4.5.2 2 Module

3

-

-

... More
4 Module

4

-

-

... More
6 Module

2

-

-

... More
8 Module

2

-

-

... More
12 Module

1

-

-

... More
Supplying and fixing following piano type switch, socket, other accessories on the existing switch box/ cover including connections etc. as per specification. 5.1.1 5/6 amps one way switch

252

-

-

... More
Bell push

5

-

-

... More
15/16 amps switch

39

-

-

... More
3 pin 5/6 amp socket outlet

53

-

-

... More
6 pin 15/16 amp socket outlet

13

-

-

... More
Plug Top 3 pin 5/6 Amps (For light plug).

12

-

-

... More
Plug Top 3 pin 16 Amps (For power plug).

19

-

-

... More
Fan regulator Electronic, step type moving all round

76

-

-

... More
Ceiling rose 3 pin 5 amps

38

-

-

... More
Batten/ angle holder

135

-

-

... More
Providing and fixing composite board for computer points having piano type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch and 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable size wooden box, 3mm thick phenolic laminated sheet cover including painting etc. as per specification.

14

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.1 5/6 amps one way switch

57

-

-

... More
Bell push

1

-

-

... More
15/16 amp switch

6

-

-

... More
3 pin 5/6 amp socket outlet

12

-

-

... More
6 pin 15/16 amp socket outlet

9

-

-

... More
6 pin 20 amp socket outlet

2

-

-

... More
Fan regulator (one module size) electronic stepped type moving all rounds

4

-

-

... More
Plug Top (Deluxe type) 3 pin 5/6 Amps (For light plug).

2

-

-

... More
Plug Top (Deluxe type) 3 pin 16 Amps (For power plug).

1

-

-

... More
25/32 amp A.C. Starter switch

3

-

-

... More
Batten/ angle holder

5

-

-

... More
Providing and fixing 16/32 amp DP surface switch with neon on suitable size wooden box including connection, testing etc. complete.

5

-

-

... More
Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification.

4

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 Deluxe

66

-

-

... More
Providing and fixing following size FRLS PVC insulated, PVC sheathed, flexible copper conductor wire on the floor/ wall, or side of the table/ door etc. as per specification. 5.8.1 0.5 sq. mm two core

56

-

-

... More
1.0 sq. mm two core

25

-

-

... More
Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification.

8

-

-

... More
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 1200 mm sweep

92

-

-

... More
Supplying, installation, testing and commissioning of following sizes Pedestal fan with telescopic arrangement for height adjustment and standard wiring/connection etc complete as per specification. P.F. should be greater than 0.9 6.3.1 400 mm sweep

4

-

-

... More
Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 6.5.1 300 mm sweep

4

-

-

... More
400 mm sweep

2

-

-

... More
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep

17

-

-

... More
380 mm sweep

4

-

-

... More
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11.1 45 cm long

6

-

-

... More
60 cm long

4

-

-

... More
90 cm long

3

-

-

... More
Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan)

16

-

-

... More
Supplying, fixing, testing and commissioning of following 230/250 volts fluorescent lamp (tube) in existing lighting luminaries as per specification. P.F. should be greater than 0.9 6.14.1 4' x 36/40 watt

30

-

-

... More
Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.15.3 9 Watt

10

-

-

... More
12 Watt

12

-

-

... More
15/16 Watt

7

-

-

... More
18/20 Watt

4

-

-

... More
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.2 5 Watt

8

-

-

... More
9 Watt

7

-

-

... More
12 Watt

6

-

-

... More
18/20 Watt (LED Rod )

5

-

-

... More
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt {4 feet}

19

-

-

... More
36 watt {4 feet}

3

-

-

... More
Supplying, fixing, testing and commissioning of following LED lamps {Inverter Type: with builtin battery backup} with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9.LED chip efficacy ratio ≥ 100 lumens /watt. 6.20.1 9 Watt

9

-

-

... More
12 Watt

6

-

-

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED Post Top Lantern fitting with perplex cover/decorative diffuser, electronic ballast and all other accessories on existing gate column/ pole bracket, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9 . LED chip efficacy ratio ≥ 100 lumens /watt. 6.23.1 25 Watt

8

-

-

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.3 25 watt

11

-

-

... More
45 watt

21

-

-

... More
60 watt

9

-

-

... More
90 watt

6

-

-

... More
120 watt

4

-

-

... More
150 watt

4

-

-

... More
Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.29.1 30 watt

2

-

-

... More
50 watt

3

-

-

... More
150 watt

2

-

-

... More
200 watt

2

-

-

... More
250 watt

3

-

-

... More
400 watt

2

-

-

... More
Supplying, installation, testing and commissioning of following surface/ concealed type fluorescent fitting (luminaries) complete with electronic ballast/ copper ballast glow type starter but without fluorescent lamp, on ceiling/ wall surface, earthing the fitting etc. as per specification. P.F. should be greater than 0.9 6.30.1 4' x 40 W single patti type

7

-

-

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts electronic ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.33.1 For 36/40 watt T8 flu. Fitting

119

-

-

... More
For 28 watt T5 flu. Fitting

6

-

-

... More
For 26 watt CFL Fitting

1

-

-

... More
For 36 watt CFL Fitting

3

-

-

... More
Supplying, fixing, testing and commissioning of glow type starter suitable for 36/40 watt T8 230/250 volts flu. lamp in existing luminaries at all locations as per specification.

211

-

-

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts polyester filled copper wound ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.35.1 For 36/40 watt T8 flu. Fitting.

102

-

-

... More
For 250 watt HPSV/ Metal halide fitting

2

-

-

... More
For 400 watt HPSV/ Metal halide fitting

1

-

-

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts electronic ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.36.3 For 250 watt HPSV/ Metal halide fitting

2

-

-

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors in existing ceiling fans/ exhaust fan at all locations as per specification. P.F. should be greater than 0.9 6.38.1 2.0 MFD

35

-

-

... More
2.5 MFD

43

-

-

... More
3.15 MFD

116

-

-

9

-

-

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors for single phase motor at all locations as per specification. P.F. should be greater than 0.9 6.39.5 15 MFD

4

-

-

... More
20 MFD

3

-

-

... More
25 MFD

2

-

-

... More
30 MFD

1

-

-

... More
Providing and fixing wooden board of suitable size (18''x 24'') for energy meter etc complete as per specification.

22

-

-

... More
Supplying, fixing, testing and commissioning of following LED batten fitting (patti) but without LED lamp on ceiling/wall surface etc as per specification. 6.64.1 1x18W

4

-

-

3

-

-

... More
Supply, Installation, testing and commissioning of following type LED Driver for LED Panel/down lights by approved make as required. 6.65.2 9-12 watt

14

-

-

... More
15 watt

7

-

-

... More
18/20 watt

6

-

-

... More
36/40 watt

2

-

-

... More
Supply, Installation, testing and commissioning of following type LED Driver for LED Street lights / Flood Lights, IP 65 by approved make as required. 6.68.2 24 watt

11

-

-

... More
36 watt

5

-

-

... More
50 watt

3

-

-

... More
Supplying and fixing wall mounted metal board of welded construction, fabricated with minimum 35 mm X 35 mm X 6 mm angle iron frame work, with 25 mm X 6 mm flat iron as intermediate members including painting etc. as per specification.

9.6

-

-

... More
Supplying and fixing metal clad busbar chamber with 2 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.7.2 100 amps x 450mm long

1

-

-

... More
Supplying and fixing metal clad busbar chamber made of 2.0 mm thick CRCA MS powder coated sheet with 4 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.8.2 100 amps x 450mm long

4

-

-

... More
200 amps x 450mm long

2

-

-

... More
Providing and fixing metal clad, SP&N switch fuse unit (re-wirable), 230/250 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.9.1 32 amps

8

-

-

... More
63 amps

4

-

-

... More
Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.10.2 63 amps

15

-

-

... More
100 amps

8

-

-

... More
200 amps

3

-

-

... More
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.2 32 amps

120

-

-

... More
63 amps

85

-

-

... More
100 amps

30

-

-

... More
200 amps

6

-

-

... More
300 amps

6

-

-

... More
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.1 3 pole MCCB, 25-63A, Fixed Thermal Release, 10KA

4

-

-

... More
3 pole MCCB, 80-100A, Fixed Thermal Release, 10KA

4

-

-

... More
3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA

3

-

-

... More
3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 25KA

3

-

-

... More
3 pole MCCB, 250A, Adjustable Thermal - Magnetic Release, 25KA

2

-

-

... More
3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA

1

-

-

... More
3 pole MCCB, 250A, Adjustable Thermal - Magnetic Release, 35KA

1

-

-

... More
3 pole MCCB, 320A, Adjustable Thermal - Magnetic Release, 35KA

1

-

-

... More
3 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 35KA

1

-

-

... More
3 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 50KA

1

-

-

... More
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.2.5 4 way, Double door

9

-

-

... More
8 way, Double door

5

-

-

... More
12 way, Double door

4

-

-

... More
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.4 4 way Double door

5

-

-

... More
6 way Double door

4

-

-

... More
8 way Double door

3

-

-

... More
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 6 amps to 32 amps

513

-

-

... More
Supplying and fixing TP MCB, 440 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.15.2 6 amps to 32 amps

3

-

-

... More
40 amps

2

-

-

... More
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.19.2 40 amps

47

-

-

... More
63 amps

14

-

-

... More
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.1 40 amps

32

-

-

... More
63 amps

100

-

-

... More
100 amps

24

-

-

... More
Supplying and fixing TPN and earth, 440 volts, industrial type, socket outlet, enclosed metal plug top along with MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification. 9.25.1 20 Amp with “C” curve TP MCB

6

-

-

... More
32 Amp with “C” curve TP MCB

3

-

-

... More
Supplying and fixing sheet steel enclosure of suitable size made of 1.6mm thick CRCA MS sheet, for 100 amps MCCB on existing metal board/ wall including painting etc as per specification.

4

-

-

... More
Providing and fixing metal clad, 4 pole, on load change over switch unit (with sheet steel enclosure), 415/500 volts, in cubicle panel including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. (Connecting lead if required shall be paid separately) 10.7.1 63 amps

2

-

-

... More
Providing and fixing 2 pole, 230/250 volts following rating power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 10.12.2 32 amps

2

-

-

... More
63 amps

1

-

-

... More
Providing and fixing 3 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 10.13.4 100 amps

2

-

-

... More
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.

5

-

-

... More
Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification

4

-

-

... More
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.20.2 Digital type

4

-

-

... More
Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.21.1 For voltmeter

6

-

-

... More
For ammeter

6

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

4

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

4

-

-

... More
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification.

94.6

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification.

1039.6

-

-

... More
Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.3.1 50 mm internal dia

15

-

-

... More
80 mm internal dia

12

-

-

... More
Supplying and fixing G.I. pipe along with wall or pole/ support with 2 Nos MS clamps for protection of under ground cable in approved manner including bolts and nuts or metal dash fasteners complete as per specification. 14.5.1 32 mm dia

15

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 15.1.2 2 x 6 sq. mm

60

-

-

... More
2 x 10 sq. mm

65

-

-

... More
3.5 x 25 sq. mm.

95

-

-

... More
3.5 x 35 sq. mm.

85

-

-

... More
3.5 x 50 sq. mm.

60

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.5.3 2 x 10 sq. mm

325

-

-

... More
2 x 16 sq. mm

75

-

-

... More
3.5 x 35 sq. mm.

115

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 25x3 mm M.S flat clamp and steel dash fastener/ G.I. bolts and nuts as per specification , IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.6.2 3.5 x 70 sq. mm.

65

-

-

... More
Supplying and hanging following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on GI bearer wire (binded at every metre) including cost of bearer wire complete as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 15.11.3 2 x 10 sq. mm. on 8 SWG GI bearer wire

510

-

-

... More
2 x 16 sq. mm. on 8 SWG GI bearer wire

55

-

-

... More
3.5 x 35 sq. mm. on 7 SWG GI bearer wire

60

-

-

... More
3.5 x 70 sq. mm. on 6 SWG GI bearer wire

60

-

-

... More
Supplying and fixing water tight terminal box made of 1.6mm thick M.S. sheet with detachable gland plate in bottom, hinged front open able cover, rubber gasket, having 1 Nos 4way connector and 1 No SPMCB inside the box for cable connection, fixed to pole with 2 Nos clamp made from 40x3mm M.S. flat with 2 No nut bolt dully painted with 2 coat of red oxide paint and 2 coat aluminium paint complete as per specification. 19.16.1 20x15x15 cms.

4

-

-

... More
30x20x15 cms.

2

-

-

... More
Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification.

48.6

-

-

... More
Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification. 23.3.2 1.5 HP, single phase

2

-

-

... More
3.0 HP, three phase

1

-

-

... More
Supplying and fixing of following sizes 'B' class G I pipe with all necessary Tee's, bends, sockets in the suction/ delivery line including cutting and threading etc. as per specification. 23.5.3 65 mm dia.

18

-

-

... More
50 mm dia.

11

-

-

... More
40 mm dia.

12

-

-

... More
Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as per specification. 23.7.3 65 mm dia.

4

-

-

... More
50 mm dia.

2

-

-

... More
40 mm dia.

3

-

-

... More
Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set

1

-

-

... More
Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification

3

-

-

... More
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification 23.14.1 3x1.5 sqmm

56

-

-

... More
3x2.5 sqmm

68

-

-

... More
3x4.0 sqmm

58

-

-

... More
Repair of submersible motor parts 100 mm dia meter opening /Rewinding and assembly with testing etc complete and reinstallation including etc 23.19.1 Rewinding of motor from 3 to 5 HP (3 phase) waterproof copper winding wir

1

-

-

... More
Rewinding of motor from 2 HP (3 phase) waterproof copper winding wire

1

-

-

... More
Rotor up to 2 HP

1

-

-

... More
Rotor up to 3 to 5 HP

1

-

-

... More
Supplying and fixing wall mounted storage/instantaneous type electric geyser, complete with inner copper container, heating element, thermostat, indicating lamp including inlet / outlet water pipe connection, electric connection testing and commissioning etc. as per specification. 24.26.2 3 Ltr Capacity Instantaneous water geyser 5 star

1

-

-

... More
6 Ltr Capacity Instantaneous water geyser 5 star

1

-

-

... More
6 Ltr. Capacity storage type geyser 5 star

1

-

-

... More
10 Ltr. Capacity storage type geyser 5 star

1

-

-

... More
15 Ltr. Capacity storage type geyser 5 star

1

-

-

... More
25 Ltr. Capacity storage type geyser 5 star

1

-

-

... More
Providing and replacing set of 3 nos wiremesh and 3 Nos wood wool/ Khas pads of size upto 55cm x 75cm (NS) of air coolar etc complete.

4

-

-

... More
Repainting of air cooler by scraping of old paint, making surface even, painting with red oxide primer & two coats of enamel paint of required shade complete.

2

-

-

... More
Providing and replacing burnt/ damaged with new water pump in existing air cooler etc complete.

6

-

-

... More
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification.

15.75

-

-

... More
Rewinding of ceiling fan by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.1.1 48” (1200 mm sweep )

84

-

-

... More
56” (1400 mm sweep )

7

-

-

... More
Rewinding of Ex-Fan motor by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.2.1 12” (300mm) Ex. Fan

22

-

-

... More
15” (380mm) Ex. Fan

8

-

-

... More
18” (450mm) Ex. Fan

2

-

-

... More
Cleaning, overhauling, servicing of ceiling/ Exhaust / wall bracket fan including greasing/ oiling, replacement of safety pins, check nuts, lock nut, nut bolts etc. making perfect alignment inluding dismentaling and refitting at site as per specification.

8

-

-

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of ceiling fan including dismentaling, disambling, assembling and reiftting as per specification.

5

-

-

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of exhaust fan including dismentaling, disambling, assembling and reiftting as per specification.

4

-

-

... More
Supplying and replacing defective 2/3 KW heating element with approved make and suitable size in existing water heater/Gyser of any make, any capacity.

4

-

-

... More
Supplying and replacing defective thermostat with approved make and suitable size in existing water heater/Gyser of any make, any capacity.

2

-

-

... More
Painting of ceiling fan in installed position with one or more coat of spray painting with synthetic enamel paint of approved brand and make to give an even shade including cleaning the surface with detergent as per specification.

10

-

-

... More
Painting of following height steel tubular poles with two coat of enamel paint of approved brand and colour including cleaning the surface as per specification: 31.11.2 Above 6 metre and upto 8 metre

4

-

-

... More
Above 8 metre and upto 10 metre

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.