Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Opening Date20 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 40,00,000.24 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

20

8400

420

... More
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

36

7776

216

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.1) Short Point

16

7072

442

... More
Long Point

14

12908

922

... More
Extra Long Point I

40

52080

1302

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.1) Short Point

18

10602

589

... More
Long Point

12

16200

1350

... More
Extra Long Point I

24

43368

1807

... More
Extra Long Point II

28

64820

2315

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1) 3 X 1.5 sq. mm in 20mm conduit

640

58880

92

... More
3 X 2.5 sq. mm in 20mm conduit

820

91020

111

... More
6 X 2.5 sq. mm in 25mm conduit

640

110080

172

... More
9 X 2.5 sq. mm in 32mm conduit

360

85680

238

... More
12 X 2.5 sq. mm in 32mm conduit

230

66240

288

... More
3 X 4 sq. mm in 25mm conduit

150

21750

145

... More
3 X 6 sq. mm in 25mm conduit

170

30940

182

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.7.1) Short Point

16

3632

227

... More
Medium Point

24

8328

347

... More
Long Point

36

16740

465

... More
Extra for providing and fixing light plug point on board in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

32

7104

222

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.10.1) Short Point

16

6832

427

... More
Long Point

24

21624

901

... More
Extra Long Point I

32

38720

1210

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.11.3) Long Point

20

23140

1157

... More
Extra Long Point I

24

38040

1585

... More
Extra Long Point II

44

90156

2049

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.13.1) 3 X 1.5 sq. mm in 20mm conduit

460

30820

67

... More
3 X 2.5 sq. mm in 20mm conduit

500

43500

87

... More
6 X 2.5 sq. mm in 25mm conduit

420

65100

155

... More
9 X 2.5 sq. mm in 32mm conduit

270

58860

218

... More
12 X 2.5 sq. mm in 32mm conduit

190

50920

268

... More
3 X 4 sq. mm in 25mm conduit

170

21760

128

... More
3 X 6 sq. mm in 25mm conduit

220

36520

166

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 3x1.5 sq. mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing 5A piano type switch, phenolic laminated sheet etc. as per specification and IS: 694 (2010) 3.1.1) Short Point

24

3960

165

... More
Medium Point

36

8604

239

... More
Long Point

64

19776

309

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing piano type 6 amp switch and 3 pin 6 amps socket outlet, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.3.1) Short Point

18

4194

233

... More
Medium Point

14

5474

391

... More
Long Point

36

20700

575

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface/ concealed, FRLS PVC conduit and providing and fixing piano type 16 amp switch and 6 pin 16 amps socket outlet, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3.4.2) Medium Point

24

13992

583

... More
Long Point

16

13680

855

... More
Extra Long Point I

12

14472

1206

... More
Extra Long Point II

14

22344

1596

... More
Wiring for light point/ exhaust fan point/ call bell point with 3x1.5 sq. mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing 5/6 amp modular type switch, modular base and cover plate etc. as per specification and IS: 694 (2010) 3.6.1) Short Point

22

4510

205

... More
Medium Point

30

8340

278

... More
Long Point

40

13960

349

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing modular type 6 Amp switch and 3 pin 6 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.8.1) Short Point

24

8160

340

... More
Long Point

16

10928

683

... More
Extra Long Point I

14

12880

920

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) and providing and fixing modular type 16 Amp switch and 6 pin 16 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.9.1) Short Point

18

7758

431

... More
Long Point

16

14992

937

... More
Extra Long Point I

12

15456

1288

... More
Extra Long Point II

14

23478

1677

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed Steel/FRLS PVC conduit and providing and fixing modular type 32 Amp SP MCB "C" curve and 3 pin 20 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.10.3) Long Point

20

26640

1332

... More
Extra Long Point I

16

29840

1865

... More
Extra Long Point II

18

44208

2456

... More
Extra Long Point III

16

48768

3048

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.1) 1 x 1.5 sq. mm

440

6600

15

... More
2 x 2.5 sq. mm

360

14040

39

... More
3 x 2.5 sq. mm

390

22230

57

... More
4 x 2.5 sq. mm

220

16280

74

... More
6 x 2.5 sq. mm

170

18530

109

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.1) 5/6 amps one way switch

110

7590

69

... More
Bell push

22

1760

80

... More
15/16 amp switch

32

2848

89

... More
3 pin 5/6 amp socket outlet

20

1920

96

... More
6 pin 15/16 amp socket outlet

14

1680

120

... More
6 pin 20 amp socket outlet

22

3168

144

... More
Fan regulator (one module size) electronic stepped type moving all rounds

52

9672

186

... More
Fan regulator (two module size) electronic stepped type moving all rounds

74

16502

223

... More
Ceiling rose 3 pin 5 amp

76

3040

40

... More
Batten/ angle holder

136

5576

41

... More
Providing and fixing following size FRLS PVC insulated, PVC sheathed, flexible copper conductor wire on the floor/ wall, or side of the table/ door etc. as per specification. 5.8.2) 1.0 sq. mm two core

560

15120

27

... More
1.0 sq. mm three core

240

8160

34

... More
Supplying, fixing, testing and commissioning of following 230/250 volts fluorescent lamp (tube) in existing lighting luminaries as per specification. P.F. should be greater than 0.9 6.14.1) 4' x 36/40 watt

220

11220

51

... More
Supplying, fixing, testing and commissioning of glow type starter suitable for 36/40 watt T8 230/250 volts flu. lamp in existing luminaries at all locations as per specification.

220

3300

15

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts polyester filled copper wound ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.35.1) For 36/40 watt T8 flu. Fitting.

190

51680

272

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors in existing ceiling fans/ exhaust fan at all locations as per specification. P.F. should be greater than 0.9 6.38.2) 2.5 MFD

190

21470

113

... More
3.15 MFD

130

14820

114

... More
Supplying and fixing wall mounted metal board of welded construction, fabricated with minimum 35 mm X 35 mm X 6 mm angle iron frame work, with 25 mm X 6 mm flat iron as intermediate members including painting etc. as per specification.

14

40054

2861

... More
Supplying and fixing metal clad busbar chamber made of 2.0 mm thick CRCA MS powder coated sheet with 4 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.8.1) 100 amps x 300mm long

16

27664

1729

... More
Providing and fixing metal clad, SP&N switch fuse unit (re-wirable), 230/250 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.9.1) 32 amps

24

23472

978

... More
63 amps

16

28192

1762

... More
Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.10.2) 63 amps

16

30640

1915

... More
100 amps

12

41916

3493

... More
200 amps

8

43360

5420

... More
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.2) 32 amps

74

6660

90

... More
63 amps

42

6804

162

... More
100 amps

32

9280

290

... More
200 amps

18

9792

544

... More
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.2.1) 4 way, Single door

24

13608

567

... More
8 way, Single door

16

11264

704

... More
12 way, Single door

12

9720

810

... More
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.4) 4 way Double door

32

54912

1716

... More
6 way Double door

16

32608

2038

... More
8 way Double door

14

35658

2547

... More
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1) 6 amps to 32 amps

440

66440

151

... More
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2) 6 amps to 32 amps

220

32560

148

... More
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.12.3) 40 amps

44

28380

645

... More
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.16.2) 6 amps to 32 amps

36

31788

883

... More
63 amps

30

39480

1316

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

6

19458

3243

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

8

49672

6209

... More
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.

90

13770

153

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.

110

13860

126

... More
Supplying and laying following sizes one number FRLS PVC insulated/ XLPE, PVC sheathed, unarmoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.8.3) 2 x 10 sq. mm

300

28200

94

... More
4 x 10 sq. mm.

220

25300

115

... More
4 x 16 sq. mm.

360

43920

122

... More
4 x 25 sq. mm.

210

30240

144

... More
Laying, binding with 14 SWG G.I. wire and hanging following sizes one number power cable of 1.1 KV grade in air with bearer wire including binding material but excluding cost of bearer wire as per specification. . 15.22.1) Upto 35 sqmm

800

30400

38

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . 15.23.2) 2 X 6 sq. mm (16 mm)

50

4600

92

... More
2 X 10 sq. mm (19 mm)

40

3760

94

... More
2 X 16 sq. mm (19 mm)

24

2280

95

... More
4 X 10 sq. mm (22 mm)

28

2744

98

... More
4 X 16 sq. mm (22 mm)

32

3232

101

... More
4 X 25 sq. mm (25 mm)

22

2288

104

... More
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification 23.14.3) 3x4.0 sqmm

620

55800

90

... More
Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp.

620

9920

16

... More
Dismentaling, Shifting, Re-installation, testing and commissioning of split type Air Conditioner unit with indoor and out door units and frames at desired locations with existing length of copper piping with insulation, necessary wiring with existing cable etc complete as per specification.

32

100768

3149

... More
Servicing of split-type air conditioner unit of all capacity by cleaning of cooling and condensing units, filters, grills and other parts, oiling/ greasing of fan motor including testing etc as per specification.

36

21780

605

... More
Replacing the burnt/ wornout sealed compressor of Window/ split type AC unit with company repaired compressor including filling of refrigrent testing for leakage, testing and commissioning of AC unit etc as per specification. 24.15.3) 1.5 ton split type AC

24

202344

8431

... More
2.0 ton split type AC

32

289792

9056

... More
Supply and filling for topping up required quantity of R-22/R-32/R-410 refrigrent in existing window/ split air conditioners as per manufacturers specification including checking for leakage before and after filling etc complete as per specification. 24.16.3) 1.5 ton split type AC

30

11280

376

... More
2.0 ton split type AC

38

15010

395

... More
Supplying, fixing, testing and commissioning of following 440 volts capacitors in WT/ Split / Tower airconditioners at all locations as per specification. 24.18.2) 45 MFD

38

20102

529

... More
50 MFD

26

12142

467

... More
Supplying and replacing following spares/ accessories in window/ split AC 24.19.2) Electronic control PCB for Split/AC

24

35544

1481

... More
Blower motor for indoor unit of Split AC

24

36744

1531

... More
Fan motor for outdoor unit of Split AC

32

55424

1732

... More
Fan motor blade for outdoor unit of Split AC

20

12480

624

... More
Swing motor for WT/ Split AC

20

9460

473

... More
Remote for WT/ split AC

16

6320

395

... More
Dead Nut 1/4"

36

2232

62

... More
Dead Nut 1/2"

28

2016

72

... More
Dead Nut 5/8"

24

2208

92

... More
Annual servicing of split- type (inverter and non inverter) air conditioners unit of all capacity by cleaning of cooling and condensing coils, filters, grills and other parts, oiling/ greasing of fan motor , checking for leakage including testing and gas charging etc complete as per specification

36

84096

2336

... More
Rewinding of ceiling fan by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.1.1) 48” (1200 mm sweep )

100

34900

349

... More
Rewinding of Ex-Fan motor by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.2.1) 12” (300mm) Ex. Fan

68

26112

384

... More
Cleaning, overhauling, servicing of ceiling/ Exhaust / wall bracket fan including greasing/ oiling, replacement of safety pins, check nuts, lock nut, nut bolts etc. making perfect alignment inluding dismentaling and refitting at site as per specification.

100

9700

97

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of ceiling fan during overhauling as per specification.

77

4620

60

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of ceiling fan including dismentaling, disambling, assembling and reiftting as per specification.

70

5600

80

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of exhaust fan etc as per specification.

48

3120

65

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of exhaust fan including dismentaling, disambling, assembling and reiftting as per specification.

54

4536

84

... More
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification.

78.68

13218

168



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.