Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Opening Date9 Oct 2024
Closing Date28 Oct 2024
Tender Amount₹ 75,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface/ concealed, Steel/FRLS PVC conduit and providing and fixing 5/6 amp modular type switch, modular base and cover plate etc. as per specification and IS: 694 (2010)

58

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing modular type 6 Amp switch and 3 pin 6 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.8.1 Short Point

143

-

-

... More
Medium Point

86

-

-

... More
Extra Long Point II

123

-

-

... More
Extra Long Point III

80

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) and providing and fixing modular type 16 Amp switch and 6 pin 16 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.9.1 Short Point

98

-

-

... More
Long Point

68

-

-

... More
Extra Long Point II

53

-

-

... More
Extra Long Point III

46

-

-

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed Steel/FRLS PVC conduit and providing and fixing modular type 32 Amp SP MCB "C" curve and 3 pin 20 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.10.1 Short Point

32

-

-

... More
Long Point

43

-

-

... More
Extra Long Point I

24

-

-

... More
Extra Long Point III

68

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.2 2 x 1.5 sq. mm

1584

-

-

... More
3 x 1.5 sq. mm

1684

-

-

... More
3 x 2.5 sq. mm

732

-

-

... More
6 x 2.5 sq. mm

684

-

-

... More
9 x 2.5 sq. mm

457

-

-

... More
10 x 2.5 sq. mm

379

-

-

... More
3 x 4 sq. mm

452

-

-

... More
3 x 6 sq. mm

384

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.1 5/6 amps one way switch

352

-

-

... More
5/6 amps two way switch

43

-

-

... More
Bell push

32

-

-

... More
15/16 amp switch

257

-

-

... More
3 pin 5/6 amp socket outlet

343

-

-

... More
6 pin 15/16 amp socket outlet

224

-

-

... More
Fan regulator (one module size) electronic stepped type moving all rounds

97

-

-

... More
Fan regulator (two module size) electronic stepped type moving all rounds

123

-

-

... More
Plug Top (Deluxe type) 3 pin 5/6 Amps (For light plug).

76

-

-

... More
Plug Top (Deluxe type) 3 pin 16 Amps (For power plug).

84

-

-

... More
RJ-45 {CAT6} socket outlet

38

-

-

... More
RJ-45 {CAT6} LAN, I/O Box

34

-

-

... More
Telephone socket outlet

42

-

-

... More
T.V. antenna socket outlet

28

-

-

... More
Computer Outlet Jack

17

-

-

... More
25/32 amp A.C. Starter switch

96

-

-

... More
Ceiling rose 3 pin 5 amp

168

-

-

... More
Batten/ angle holder

125

-

-

... More
Providing and fixing 16/32 amp DP surface switch with neon on suitable size wooden box including connection, testing etc. complete.

134

-

-

... More
Supplying and fixing of following sizes PVC switch box suitable for modular switches with modular base and cover plates on surface complete as per specification 4.3.1 94 mm X 94 mm (1/2 Module)

57

-

-

... More
118mmX94mm (3 Module)

85

-

-

... More
150mmX94mm (4 Module)

94

-

-

... More
205mmX94mm (6 Module)

52

-

-

... More
8 Module

36

-

-

... More
12 Module

95

-

-

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 4.4.1 75mmX75mm (1/2 Module)

95

-

-

... More
100mmX75mm (3 Module)

58

-

-

... More
125mmX75mm (4 Module)

59

-

-

... More
200mmX75mm (6 Module)

95

-

-

... More
125mmX125mm (8 Module)

83

-

-

... More
200mmX150mm (12 Module)

72

-

-

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 4.5.1 1 Module

64

-

-

... More
3 Module

72

-

-

... More
4 Module

85

-

-

... More
6 Module

90

-

-

... More
8 Module

84

-

-

... More
12 Module

93

-

-

... More
Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification.

108

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.1 Ordinary (simple)

29

-

-

... More
Deluxe

32

-

-

... More
Providing and fixing following size FRLS PVC insulated, PVC sheathed, flexible copper conductor wire on the floor/ wall, or side of the table/ door etc. as per specification. 5.8.1 0.5 sq. mm two core

1462

-

-

... More
1.0 sq. mm two core

1743

-

-

... More
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification.

97

-

-

... More
Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification.

94

-

-

... More
Providing and fixing fan clamp made of 3mm thick MS flat on existing iron trusses/ girder including necessary bolts and nuts etc. as per specification.

12

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

-

-

-

... More
Short Point

102

-

-

... More
Medium Point

134

-

-

... More
Long Point

91

-

-

... More
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

68

-

-

... More
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

342

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

-

-

-

... More
Short Point

98

-

-

... More
Medium Point

46

-

-

... More
Long Point

79

-

-

... More
Extra Long Point I

80

-

-

... More
Extra Long Point II

96

-

-

... More
Extra Long Point III

64

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

-

-

-

... More
Short Point

14

-

-

... More
Medium Point

16

-

-

... More
Long Point

10

-

-

... More
Extra Long Point I

13

-

-

... More
Extra Long Point II

9

-

-

... More
Extra Long Point III

12

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

-

-

-

... More
3 X 1.5 sq. mm in 20mm conduit

895

-

-

... More
3 X 2.5 sq. mm in 20mm conduit

858

-

-

... More
6 X 2.5 sq. mm in 25mm conduit

764

-

-

... More
9 X 2.5 sq. mm in 32mm conduit

663

-

-

... More
12 X 2.5 sq. mm in 32mm conduit

587

-

-

... More
3 X 4 sq. mm in 25mm conduit

436

-

-

... More
3 X 6 sq. mm in 25mm conduit

328

-

-

... More
6 X 10 sq. mm in 40mm conduit

433

-

-

... More
6 X 16 sq. mm in 50mm conduit

430

-

-

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5)

-

-

-

... More
20 mm

-

-

-

... More
25 mm

-

-

-

... More
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 1200 mm sweep

58

-

-

... More
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep

29

-

-

... More
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11.1 45 cm long

24

-

-

... More
90 cm long

22

-

-

... More
300 cm long

12

-

-

... More
Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan)

58

-

-

... More
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt {4 feet}

96

-

-

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors in existing ceiling fans/ exhaust fan at all locations as per specification. P.F. should be greater than 0.9. 6.38.2 2.5 MFD

95

-

-

... More
3.15 MFD

86

-

-

... More
4 MFD

74

-

-

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors for single phase motor at all locations as per specification. P.F. should be greater than 0.9 6.39.2 8 MFD

4

-

-

... More
10 MFD

5

-

-

... More
12 MFD

3

-

-

... More
15 MFD

6

-

-

... More
25 MFD

4

-

-

... More
30 MFD

3

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated , copper conductor, single core wire, earthing etc. complete as per specification.

79

-

-

... More
Installation, testing and commissioning of wall/ cabin fan, etc. complete as per specification.

28

-

-

... More
Installation of following size exhaust fan in the existing opening including connection, testing, commissioning etc. as per specification. 6.42.1 Upto 300 mm sweep

14

-

-

... More
380 mm sweep

10

-

-

... More
450 mm sweep

8

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for exhaust fan of all sizes.

9

-

-

... More
Erection of all type of GLS lamps/ CFL/LED fitting on wall /ceiling of all sizes and all shapes complete with all accessories including connection etc. as per specification.

124

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. including connection with 1.5 sq. mm FRLS PVC insulated , copper conductor, single core wire and earthing etc. as per specification. 6.45.1 Directly on ceiling/ wall

86

-

-

... More
Installation, testing and commissioning of all types of street light fittings with all accessories and lamps on street light bracket fixed on wall/ pole, including connection with FRLS PVC insulated , copper conductor, single core wire upto 2 metre length, earthing etc. as per specification.

39

-

-

... More
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as per specification.

64

-

-

... More
Fabrication and installation of angle iron including angle size 50 mm x 5 mm thick with labour charges including materials as per specification

127

-

-

... More
Supply, Installation, testing and commissioning of following type LED Driver for LED Panel/down lights by approved make as required. 6.65.1 3-6 watt

58

-

-

... More
9-12 watt

128

-

-

... More
18/20 watt

123

-

-

... More
Supply, Installation, testing and commissioning of following type LED Driver for COB lights by approved make as required. 6.66.1 6-15 watt

23

-

-

... More
18/20 watt

14

-

-

... More
40 watt

18

-

-

... More
Supplying , Installation, testing and commissioning of following type LED Driver for LED Street lights / Flood Lights, IP 65 by approved make as required. 6.68.1 10 watt

12

-

-

... More
24 watt

9

-

-

... More
36 watt

13

-

-

... More
50 watt

18

-

-

... More
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.

48

-

-

... More
9 Watt

85

-

-

... More
12 Watt

94

-

-

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt.

-

-

-

... More
30 watt

8

-

-

... More
36 watt

18

-

-

... More
45 watt

12

-

-

... More
60 watt

24

-

-

... More
120 watt

9

-

-

... More
Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.

-

-

-

... More
24 watt, size 300 x 300mm

38

-

-

... More
36 watt, size 600 x 600mm

47

-

-

... More
Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.

-

-

-

... More
9 watt

14

-

-

... More
30 watt

6

-

-

... More
50 watt

12

-

-

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 1.15.2 25 mm

257

-

-

... More
32 mm

142

-

-

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 2.15.2 25 mm

264

-

-

... More
32 mm

142

-

-

... More
Supplying and fixing of following sizes PVC casing caping along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5). 2.16.2 25x16 mm

174

-

-

... More
32x16 mm

237

-

-

... More
Supplying and drawing following pair 0.5 mm FR PVC insulated copper conductor, unarmored telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification. 3.12.1 1 Pair

146

-

-

... More
2 Pair

153

-

-

... More
4 Pair

97

-

-

... More
Supplying and drawing following grade co-axial TV wire FR PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed Steel/FRLS PVC conduit as per specification. 3.13.1 RG-6 grade

85

-

-

... More
RG-11 grade

74

-

-

... More
Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification

852

-

-

... More
Supplying and drawing following pair 0.5 mm FR PVC insulated stranded copper conductor armoured telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 3.15.1 10 Pair

123

-

-

... More
20 Pair

90

-

-

... More
Providing and replacing set of 3 nos wiremesh and 3 Nos wood wool/ Khas pads of size upto 55cm x 75cm (NS) of air coolar etc complete.

18

-

-

... More
Repainting of air cooler by scraping of old paint, making surface even, painting with red oxide primer & two coats of enamel paint of required shade complete.

26

-

-

... More
Providing and replacing burnt/ damaged with new water pump in existing air cooler etc complete.

20

-

-

... More
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification.

48.25

-

-

... More
Rewinding of ceiling fan by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.1.1 48” (1200 mm sweep )

63

-

-

... More
Rewinding of Ex-Fan motor by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.2.1 12” (300mm) Ex. Fan

35

-

-

... More
18” (450mm) Ex. Fan

21

-

-

... More
Cleaning, overhauling, servicing of ceiling/ Exhaust / wall bracket fan including greasing/ oiling, replacement of safety pins, check nuts, lock nut, nut bolts etc. making perfect alignment inluding dismentaling and refitting at site as per specification.

96

-

-

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of ceiling fan including dismentaling, disambling, assembling and reiftting as per specification.

94

-

-

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of exhaust fan including dismentaling, disambling, assembling and reiftting as per specification.

86

-

-

... More
Supplying and replacing defective 2/3 KW heating element with approved make and suitable size in existing water heater/Gyser of any make, any capacity.

75

-

-

... More
Supplying and replacing defective thermostat with approved make and suitable size in existing water heater/Gyser of any make, any capacity.

63

-

-

... More
Painting of ceiling fan in installed position with one or more coat of spray painting with synthetic enamel paint of approved brand and make to give an even shade including cleaning the surface with detergent as per specification.

68

-

-

... More
Painting of following height steel tubular poles with two coat of enamel paint of approved brand and colour including cleaning the surface as per specification: 31.11.1 upto 6 metre

12

-

-

... More
Above 8 metre and upto 10 metre

9

-

-

... More
Painting new steel and other metallic surface with red oxide zinc chromide primer paint complete with supply of material labour etc. including preparation of surface.

27

-

-

... More
Supplying and fixing wall/ floor mounted metal board of welded construction, fabricated with minimum 50mmX 50mm X 6mm angle iron frame work, with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gears including painting etc. as per specification.

49

-

-

... More
Supplying and fixing wall mounted metal board of welded construction, fabricated with minimum 35 mm X 35 mm X 6 mm angle iron frame work, with 25 mm X 6 mm flat iron as intermediate members including painting etc. as per specification.

38

-

-

... More
Supplying and fixing metal clad busbar chamber with 2 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.7.1 100 amps x 300mm long

12

-

-

... More
100 amps x 450mm long

18

-

-

... More
Providing and fixing metal clad, SP&N switch fuse unit (re-wirable), 230/250 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.9.1 32 amps

12

-

-

... More
63 amps

18

-

-

... More
Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.10.1 32 amps

-

-

-

... More
63 amps

6

-

-

... More
100 amps

9

-

-

... More
200 amps

12

-

-

... More
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.2 32 amps

6

-

-

... More
63 amps

12

-

-

... More
100 amps

9

-

-

... More
Providing and making interconnection in cubical panel between BBC and switchgears with following size FRLS PVC insulated copper conductor wire lead of length upto 50cm including providing copper thimbles on both ends as per specification (To be measured separately for each phase/ neutral). 7.17.1 10 sqmm (32 amp)

64

-

-

... More
16 sqmm (63 amp)

47

-

-

... More
35 sqmm (125 amps)

58

-

-

... More
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.2 Above 300 mm and upto 450 mm deep

9.75

-

-

... More
Above 450 mm and upto 600 mm deep

18

-

-

... More
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.20.1 100 amp (20x5mm)

12

-

-

... More
200 amp (30x5mm)

9

-

-

... More
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.21.1 100 amp (20x3mm)

6

-

-

... More
200 amp (25x5mm)

10

-

-

... More
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.3 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA

14

-

-

... More
3 pole MCCB, 125A, Adjustable Thermal - Magnetic Release, 25KA

6

-

-

... More
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.2.1 4 way, Single door

5

-

-

... More
4 way, Double door

4

-

-

... More
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.1 4 way Single door

2

-

-

... More
4 way Double door

7

-

-

... More
6 way Single door

3

-

-

... More
8 way Double door

4

-

-

... More
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1 6 amps to 32 amps

97

-

-

... More
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 6 amps to 32 amps

86

-

-

... More
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.12.2 6 amps to 32 amps

84

-

-

... More
63 amps

73

-

-

... More
Supplying and fixing TP MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.14.2 6 amps to 32 amps

32

-

-

... More
63 amps

28

-

-

... More
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.2 63 amps

24

-

-

... More
100 amps

29

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.22.3 63 amps

8

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as per specification.

27

-

-

... More
Supplying and fixing sheet steel enclosure of suitable size made of 1.6mm thick CRCA MS sheet, for 100 amps MCCB on existing metal board/ wall including painting etc as per specification.

32

-

-

... More
Providing and fixing single phasing preventer in existing panel including connection, testing and commissioning as per specification.

15

-

-

... More
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.

56

-

-

... More
Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification

8

-

-

... More
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.20.1 Analog type

12

-

-

... More
Digital type

16

-

-

... More
Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set

5

-

-

... More
Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp.

463

-

-

... More
Installation & lifting out of pump set from tubewell/sumpwell and submersible pump.

-

-

-

... More
Provision for lifting out unworkable submersible pump from tubewell from any depth with G.I./UPVC pipe shifting to work shop as per required suitable site.

4

-

-

... More
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant.

-

-

-

... More
3x2.5 sqmm

157

-

-

... More
3x4.0 sqmm

253

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

14

-

-

... More
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification.

342

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

246

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

153

-

-

... More
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

169

-

-

... More
Excavation for foundation in soft soil/hard soil including dressing of sides and ramming of bottoms, lifting and getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres

46

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.3.23 4 x 16 sq. mm.

537

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing masonry open duct as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.4.12 3.5 x 35 sq. mm.

484

-

-

... More
3.5 x 70 sq. mm.

369

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 15.23.12 3½ X 25 sq. mm (25 mm)

87

-

-

... More
3½ X 35 sq. mm (28 mm)

64

-

-

... More
3½ X 50 sq. mm (32 mm)

39

-

-

... More
3½ X 70 sq. mm (35 mm)

37

-

-

... More
3½ X 95 sq. mm (38 mm)

65

-

-

... More
4 X 16 sq. mm (22 mm)

73

-

-

... More
Designing & Providing of suitable RCC trench in cement concrete 1:3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) for laying of cable inground including execavation, steel reinforcement (minimum 35.75 kg per cum), 4" drain wall, drain cover, frame work, curing & refilling of excavated soil etc as per specification.

32

-

-

... More
Supplying and fixing wall mounted storage/instantaneous type electric geyser, complete with inner copper container, heating element, thermostat, indicating lamp including inlet / outlet water pipe connection, electric connection testing and commissioning etc. as per specification. 24.26.8 15 Ltr. Capacity storage type geyser 5 star

7

-

-

... More
25 Ltr. Capacity storage type geyser 5 star

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.