Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Public Works Department - PWD Tender

Works
Hiring of Vehicles
Manpower Supply
Opening Date12 Dec 2024
Closing Soon26 Dec 2024
Tender Amount₹ 90,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with piano type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of phenolic laminated sheet and M.S. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

24

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 6 amp switch and 3 pin 6 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.4.2 Medium Point

9

-

-

... More
Long Point

4

-

-

... More
Extra Long Point I

5

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 16 amp switch and 6 pin 16 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.5.2 Medium Point

11

-

-

... More
Long Point

9

-

-

... More
Extra Long Point I

8

-

-

... More
Extra Long Point II

4

-

-

... More
Extra Long Point III

3

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point

3

-

-

... More
Medium Point

2

-

-

... More
Long Point

2

-

-

... More
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

4

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.2 Medium Point

3

-

-

... More
Long Point

2

-

-

... More
Extra Long Point I

2

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.3 Long Point

5

-

-

... More
Extra Long Point I

4

-

-

... More
Extra Long Point II

3

-

-

... More
Extra Long Point III

3

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1 3 X 1.5 sq. mm in 20mm conduit

245

-

-

... More
3 X 2.5 sq. mm in 20mm conduit

140

-

-

... More
6 X 2.5 sq. mm in 25mm conduit

96

-

-

... More
9 X 2.5 sq. mm in 32mm conduit

88

-

-

... More
12 X 2.5 sq. mm in 32mm conduit

74

-

-

... More
3 X 4 sq. mm in 25mm conduit

85

-

-

... More
3 X 6 sq. mm in 25mm conduit

36

-

-

... More
6 X 6 sq. mm in 32mm conduit

8

-

-

... More
6 X 10 sq. mm in 40mm conduit

25

-

-

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 1.15.1 20 mm

12

-

-

8

-

-

4

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp piano type switch, phenolic laminated sheet, suitable size M.S. box etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.1.1 Short Point

23

-

-

... More
Medium Point

46

-

-

... More
Long Point

45

-

-

... More
Extra for providing and fixing light plug point on board in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with piano type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of phenolic laminated sheet and M.S. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

44

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 6 amp switch and 3 pin 6 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.4.2 Medium Point

9

-

-

... More
Long Point

8

-

-

... More
Extra Long Point I

11

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with piano type 16 amp switch and 6 pin 16 amps socket outlet with suitable size M.S. box, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.5.2 Medium Point

6

-

-

... More
Long Point

8

-

-

... More
Extra Long Point I

9

-

-

... More
Extra Long Point II

6

-

-

... More
Extra Long Point III

3

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.13.1 3 X 1.5 sq. mm in 20mm conduit

346

-

-

... More
3 X 2.5 sq. mm in 20mm conduit

402

-

-

... More
6 X 2.5 sq. mm in 25mm conduit

197

-

-

... More
9 X 2.5 sq. mm in 32mm conduit

103

-

-

... More
12 X 2.5 sq. mm in 32mm conduit

86

-

-

... More
3 X 4 sq. mm in 25mm conduit

201

-

-

... More
3 X 6 sq. mm in 25mm conduit

285

-

-

... More
6 X 6 sq. mm in 32mm conduit

75

-

-

... More
3 X 10 sq. mm in 25mm conduit

54

-

-

... More
6 X 10 sq. mm in 40mm conduit

46

-

-

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 2.15.1 20 mm

45

-

-

35

-

-

... More
Supplying and fixing of following sizes PVC casing caping along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5). 2.16.1 20x12 mm

44

-

-

... More
25x16 mm

30

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 3x1.5 sq. mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing 5A piano type switch, phenolic laminated sheet etc. as per specification and IS: 694 (2010) 3.1.1 Short Point

3

-

-

... More
Medium Point

3

-

-

... More
Long Point

2

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing piano type 6 amp switch and 3 pin 6 amps socket outlet, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.3.2 Medium Point

3

-

-

... More
Long Point

2

-

-

... More
Extra Long Point I

2

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface/ concealed, FRLS PVC conduit and providing and fixing piano type 16 amp switch and 6 pin 16 amps socket outlet, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3.4.3 Long Point

3

-

-

... More
Extra Long Point I

4

-

-

... More
Extra Long Point II

2

-

-

... More
Extra Long Point III

3

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.2 2 x 1.5 sq. mm

603

-

-

... More
3 x 1.5 sq. mm

711

-

-

... More
2 x 2.5 sq. mm

540

-

-

... More
3 x 2.5 sq. mm

532

-

-

... More
3 x 4 sq. mm

261

-

-

... More
3 x 6 sq. mm

144

-

-

... More
6 x 6 sq. mm

116

-

-

... More
3 x 10 sq. mm

93

-

-

... More
6 x 10 sq. mm

95

-

-

... More
Supplying and fixing of metal box of following sizes (nominal size) in recess with suitable size phenolic laminated sheet cover in front including painting etc as per specification. 4.1.1 75 mm X 75 mm X 60 mm deep

12

-

-

... More
100 mm X 100 mm X 60 mm deep

8

-

-

... More
150 mm X 150 mm X 60 mm deep

6

-

-

... More
180 mm X 100 mm X 60 mm deep

6

-

-

... More
200 mm X 150 mm X 60 mm deep

4

-

-

... More
200 mm X 300 mm X 60 mm deep

5

-

-

... More
250 mm X 300 mm X 60 mm deep

6

-

-

... More
Supplying and fixing of following sizes wooden switch box made of wooden plank side wall and base including 3mm thick phenolic laminated sheet cover on surface complete as per specification 4.2.1 100mmX100mm

11

-

-

... More
150mmX75mm

10

-

-

... More
150mmX150mm

6

-

-

... More
180mmX100mm

4

-

-

... More
300mmX350mm

4

-

-

... More
Supplying and fixing of following sizes PVC switch box suitable for modular switches with modular base and cover plates on surface complete as per specification 4.3.1 94 mm X 94 mm (1/2 Module)

7

-

-

... More
150mmX94mm (4 Module)

9

-

-

... More
205mmX94mm (6 Module)

6

-

-

... More
8 Module

11

-

-

... More
12 Module

4

-

-

... More
16 Module

3

-

-

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 4.5.2 2 Module

7

-

-

... More
4 Module

9

-

-

... More
6 Module

5

-

-

... More
8 Module

4

-

-

... More
12 Module

2

-

-

... More
16 Module

2

-

-

... More
Supplying and fixing following piano type switch, socket, other accessories on the existing switch box/ cover including connections etc. as per specification. 5.1.1 5/6 amps one way switch

536

-

-

... More
5/6 amps two way switch

4

-

-

... More
Bell push

9

-

-

... More
15/16 amps switch

82

-

-

... More
3 pin 5/6 amp socket outlet

124

-

-

... More
6 pin 15/16 amp socket outlet

30

-

-

... More
Plug Top 3 pin 5/6 Amps (For light plug).

27

-

-

... More
Plug Top 3 pin 16 Amps (For power plug).

45

-

-

... More
Fan regulator Electronic, step type moving all round

159

-

-

... More
Ceiling rose 3 pin 5 amps

83

-

-

... More
Pendent holder

6

-

-

... More
Batten/ angle holder

282

-

-

... More
Providing and fixing composite board for computer points having piano type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch and 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable size wooden box, 3mm thick phenolic laminated sheet cover including painting etc. as per specification.

28

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.1 5/6 amps one way switch

129

-

-

... More
Bell push

3

-

-

... More
15/16 amp switch

12

-

-

... More
3 pin 5/6 amp socket outlet

24

-

-

... More
6 pin 15/16 amp socket outlet

17

-

-

... More
6 pin 20 amp socket outlet

16

-

-

... More
Fan regulator (one module size) electronic stepped type moving all rounds

8

-

-

... More
Plug Top (Deluxe type) 3 pin 5/6 Amps (For light plug).

4

-

-

... More
Plug Top (Deluxe type) 3 pin 16 Amps (For power plug).

3

-

-

... More
25/32 amp A.C. Starter switch

12

-

-

... More
Batten/ angle holder

17

-

-

... More
Providing and fixing 16/32 amp DP surface switch with neon on suitable size wooden box including connection, testing etc. complete.

15

-

-

... More
Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification.

10

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 Deluxe

138

-

-

... More
Providing and fixing following size FRLS PVC insulated, PVC sheathed, flexible copper conductor wire on the floor/ wall, or side of the table/ door etc. as per specification. 5.8.1 0.5 sq. mm two core

133

-

-

... More
1.0 sq. mm two core

80

-

-

... More
Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification.

24

-

-

... More
Providing and fixing fan clamp made of 3mm thick MS flat on existing iron trusses/ girder including necessary bolts and nuts etc. as per specification.

12

-

-

... More
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 1200 mm sweep

147

-

-

... More
Supplying, installation, testing and commissioning of following sizes Pedestal fan with telescopic arrangement for height adjustment and standard wiring/connection etc complete as per specification. P.F. should be greater than 0.9 6.3.1 400 mm sweep

8

-

-

... More
Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 6.5.1 300 mm sweep

9

-

-

... More
400 mm sweep

5

-

-

... More
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep

29

-

-

... More
380 mm sweep

7

-

-

... More
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11.1 45 cm long

10

-

-

... More
60 cm long

9

-

-

... More
90 cm long

8

-

-

... More
Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan)

41

-

-

... More
Supplying, fixing, testing and commissioning of following 230/250 volts fluorescent lamp (tube) in existing lighting luminaries as per specification. P.F. should be greater than 0.9 6.14.1 4' x 36/40 watt

38

-

-

... More
Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.15.3 9 Watt

19

-

-

... More
12 Watt

23

-

-

... More
15/16 Watt

18

-

-

... More
18/20 Watt

11

-

-

... More
Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.16.1 24 watt, size 300 x 300mm

6

-

-

... More
36 watt, size 600 x 600mm

5

-

-

... More
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.2 5 Watt

18

-

-

... More
9 Watt

18

-

-

... More
12 Watt

16

-

-

... More
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt {4 feet}

32

-

-

... More
36 watt {4 feet}

12

-

-

... More
Supplying, fixing, testing and commissioning of following LED lamps {Inverter Type: with builtin battery backup} with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9.LED chip efficacy ratio ≥ 100 lumens /watt. 6.20.1 9 Watt

13

-

-

... More
12 Watt

10

-

-

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED BOLLARD fitting cool white/warm white {Colour Temperature 3000/4000/5600/6000 K} with electronic driver, heat sink, capacitor and all other accessories on existing foundation/ pole bracket, including connection, earthing etc complete as per specification. P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.22.1 9 watt

9

-

-

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED Post Top Lantern fitting with perplex cover/decorative diffuser, electronic ballast and all other accessories on existing gate column/ pole bracket, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9 . LED chip efficacy ratio ≥ 100 lumens /watt. 6.23.1 25 Watt

12

-

-

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.3 25 watt

19

-

-

... More
45 watt

32

-

-

... More
60 watt

14

-

-

... More
90 watt

11

-

-

... More
120 watt

12

-

-

... More
150 watt

11

-

-

... More
Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.29.1 30 watt

4

-

-

... More
50 watt

6

-

-

... More
150 watt

4

-

-

... More
200 watt

3

-

-

... More
250 watt

4

-

-

... More
400 watt

3

-

-

... More
Supplying, installation, testing and commissioning of following surface/ concealed type fluorescent fitting (luminaries) complete with electronic ballast/ copper ballast glow type starter but without fluorescent lamp, on ceiling/ wall surface, earthing the fitting etc. as per specification. P.F. should be greater than 0.9 6.30.1 4' x 40 W single patti type

10

-

-

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts electronic ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.33.1 For 36/40 watt T8 flu. Fitting

216

-

-

... More
For 28 watt T5 flu. Fitting

10

-

-

... More
For 26 watt CFL Fitting

3

-

-

... More
For 36 watt CFL Fitting

5

-

-

... More
Supplying, fixing, testing and commissioning of glow type starter suitable for 36/40 watt T8 230/250 volts flu. lamp in existing luminaries at all locations as per specification.

423

-

-

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts polyester filled copper wound ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.35.1 For 36/40 watt T8 flu. Fitting.

194

-

-

... More
For 250 watt HPSV/ Metal halide fitting

4

-

-

... More
For 400 watt HPSV/ Metal halide fitting

3

-

-

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts electronic ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.36.3 For 250 watt HPSV/ Metal halide fitting

4

-

-

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors in existing ceiling fans/ exhaust fan at all locations as per specification. P.F. should be greater than 0.9 6.38.1 2.0 MFD

58

-

-

... More
2.5 MFD

73

-

-

... More
3.15 MFD

199

-

-

17

-

-

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors for single phase motor at all locations as per specification. P.F. should be greater than 0.9 6.39.5 15 MFD

8

-

-

... More
20 MFD

5

-

-

... More
25 MFD

4

-

-

... More
30 MFD

3

-

-

... More
Providing and fixing wooden board of suitable size (18''x 24'') for energy meter etc complete as per specification.

63

-

-

... More
Supplying, fixing, testing and commissioning of following LED batten fitting (patti) but without LED lamp on ceiling/wall surface etc as per specification. 6.64.1 1x18W

3

-

-

2

-

-

... More
Supply, Installation, testing and commissioning of following type LED Driver for LED Panel/down lights by approved make as required. 6.65.2 9-12 watt

41

-

-

... More
15 watt

36

-

-

... More
18/20 watt

32

-

-

... More
36/40 watt

22

-

-

... More
Supply, Installation, testing and commissioning of following type LED Driver for COB lights by approved make as required. 6.66.1 6-15 watt

3

-

-

... More
18/20 watt

3

-

-

... More
Supply, Installation, testing and commissioning of following type LED Driver for LED Street lights / Flood Lights, IP 65 by approved make as required. 6.68.2 24 watt

48

-

-

... More
36 watt

36

-

-

... More
50 watt

20

-

-

... More
Supplying and fixing wall mounted metal board of welded construction, fabricated with minimum 35 mm X 35 mm X 6 mm angle iron frame work, with 25 mm X 6 mm flat iron as intermediate members including painting etc. as per specification.

8.64

-

-

... More
Supplying and fixing metal clad busbar chamber with 2 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.7.2 100 amps x 450mm long

3

-

-

... More
Supplying and fixing metal clad busbar chamber made of 2.0 mm thick CRCA MS powder coated sheet with 4 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.8.2 100 amps x 450mm long

4

-

-

... More
200 amps x 450mm long

4

-

-

... More
Providing and fixing metal clad, SP&N switch fuse unit (re-wirable), 230/250 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.9.1 32 amps

7

-

-

... More
63 amps

4

-

-

... More
Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.10.2 63 amps

29

-

-

... More
100 amps

10

-

-

... More
200 amps

5

-

-

... More
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.2 32 amps

113

-

-

... More
63 amps

67

-

-

... More
100 amps

58

-

-

... More
200 amps

9

-

-

... More
300 amps

8

-

-

... More
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.1 3 pole MCCB, 25-63A, Fixed Thermal Release, 10KA

6

-

-

... More
3 pole MCCB, 80-100A, Fixed Thermal Release, 10KA

6

-

-

... More
3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA

4

-

-

... More
3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 25KA

2

-

-

... More
3 pole MCCB, 250A, Adjustable Thermal - Magnetic Release, 25KA

2

-

-

... More
3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA

1

-

-

... More
3 pole MCCB, 250A, Adjustable Thermal - Magnetic Release, 35KA

1

-

-

... More
3 pole MCCB, 320A, Adjustable Thermal - Magnetic Release, 35KA

1

-

-

... More
3 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 35KA

1

-

-

... More
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.2.5 4 way, Double door

16

-

-

... More
8 way, Double door

11

-

-

... More
12 way, Double door

9

-

-

... More
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.4 4 way Double door

9

-

-

... More
6 way Double door

6

-

-

... More
8 way Double door

4

-

-

... More
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 6 amps to 32 amps

846

-

-

... More
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.12.3 40 amps

14

-

-

... More
Supplying and fixing TP MCB, 440 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.15.2 6 amps to 32 amps

10

-

-

... More
40 amps

8

-

-

... More
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.19.2 40 amps

93

-

-

... More
63 amps

27

-

-

... More
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.1 40 amps

68

-

-

... More
63 amps

186

-

-

... More
100 amps

39

-

-

... More
Supplying and fixing TPN and earth, 440 volts, industrial type, socket outlet, enclosed metal plug top along with MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification. 9.25.1 20 Amp with “C” curve TP MCB

7

-

-

... More
32 Amp with “C” curve TP MCB

3

-

-

... More
Supplying and fixing sheet steel enclosure of suitable size made of 1.6mm thick CRCA MS sheet, for 100 amps MCCB on existing metal board/ wall including painting etc as per specification.

11

-

-

... More
Providing and fixing 2 pole, 230/250 volts following rating power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 10.12.2 32 amps

2

-

-

... More
63 amps

1

-

-

... More
Providing and fixing 3 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 10.13.4 100 amps

2

-

-

... More
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.

9

-

-

... More
Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification

5

-

-

... More
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.20.2 Digital type

5

-

-

... More
Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.21.1 For voltmeter

4

-

-

... More
For ammeter

4

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

3

-

-

... More
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification.

76.2

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification.

1390

-

-

... More
Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.3.1 50 mm internal dia

16

-

-

... More
80 mm internal dia

18

-

-

... More
100 mm internal dia

8

-

-

... More
150 mm internal dia

6

-

-

... More
Supplying and fixing G.I. pipe along with wall or pole/ support with 2 Nos MS clamps for protection of under ground cable in approved manner including bolts and nuts or metal dash fasteners complete as per specification. 14.5.1 32 mm dia

23

-

-

... More
40 mm dia

11

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 15.1.2 2 x 6 sq. mm

85

-

-

... More
2 x 10 sq. mm

80

-

-

... More
3.5 x 25 sq. mm.

90

-

-

... More
3.5 x 35 sq. mm.

85

-

-

... More
3.5 x 50 sq. mm.

55

-

-

... More
3.5 x 70 sq. mm.

35

-

-

... More
4 x 10 sq. mm.

105

-

-

... More
4 x 16 sq. mm.

85

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.5.3 2 x 10 sq. mm

160

-

-

... More
2 x 16 sq. mm

50

-

-

... More
3.5 x 25 sq. mm.

165

-

-

... More
3.5 x 35 sq. mm.

125

-

-

... More
4 x 10 sq. mm.

140

-

-

... More
4 x 16 sq. mm.

130

-

-

... More
Supplying and hanging following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on GI bearer wire (binded at every metre) including cost of bearer wire complete as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 15.11.3 2 x 10 sq. mm. on 8 SWG GI bearer wire

205

-

-

... More
2 x 16 sq. mm. on 8 SWG GI bearer wire

45

-

-

... More
3.5 x 25 sq. mm. on 8 SWG GI bearer wire

105

-

-

... More
3.5 x 35 sq. mm. on 7 SWG GI bearer wire

95

-

-

... More
3.5 x 70 sq. mm. on 6 SWG GI bearer wire

86

-

-

... More
4 x 10 sq. mm. on 8 SWG GI bearer wire

184

-

-

... More
4 x 16 sq. mm. on 8 SWG GI bearer wire

115

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. .15.23.12 3½ X 25 sq. mm (25 mm)

12

-

-

... More
3½ X 35 sq. mm (28 mm)

8

-

-

... More
3½ X 50 sq. mm (32 mm)

6

-

-

... More
3½ X 70 sq. mm (35 mm)

4

-

-

... More
3½ X 95 sq. mm (38 mm)

4

-

-

... More
3½ X 120 sq. mm (45 mm)

6

-

-

... More
3½ X 150 sq. mm (45 mm)

6

-

-

... More
4 X 10 sq. mm (22 mm)

18

-

-

... More
4 X 16 sq. mm (22 mm)

12

-

-

... More
Supplying and making end termination with brass compression gland and copper lugs for following size armoured copper conductor power cable of 1.1 KV grade as per specification. . 15.24.3 2 X 10 sq. mm (19 mm)

12

-

-

... More
4 X 10 sq. mm (22 mm)

10

-

-

... More
4 X 16 sq. mm (22 mm)

6

-

-

... More
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. . 15.28.2 10 sq. mm

36

-

-

... More
16 sq. mm

26

-

-

... More
25 sq. mm

28

-

-

... More
70 sq. mm

12

-

-

... More
120 sq. mm

16

-

-

... More
150 sq. mm

8

-

-

... More
Supplying and fixing PVC water tight terminal box of approved make and brand with detachable gland plate in bottom, hinged front openable cover, rubber gasket, having 1 Nos 4way connector and 1 No SPMCB inside the box for cable connection, fixed to pole with 2 Nos clamp made from 25x3mm GI flat with 2 No GI nuts bolts complete as per specification. 19.17.1 250x200x125 mm for single phase

10

-

-

... More
300x200x125 mm for 3 phase

4

-

-

... More
Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification.

2248

-

-

... More
Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification. 23.3.2 1.5 HP, single phase

1

-

-

... More
3.0 HP, three phase

1

-

-

... More
Supplying and fixing of following sizes 'B' class G I pipe with all necessary Tee's, bends, sockets in the suction/ delivery line including cutting and threading etc. as per specification. 23.5.3 65 mm dia.

30

-

-

... More
50 mm dia.

16

-

-

... More
40 mm dia.

25

-

-

... More
Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as per specification. 23.7.3 65 mm dia.

6

-

-

... More
50 mm dia.

2

-

-

... More
40 mm dia.

4

-

-

... More
Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set

1

-

-

... More
Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification

2

-

-

... More
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification 23.14.1 3x1.5 sqmm

48

-

-

... More
3x2.5 sqmm

46

-

-

... More
3x4.0 sqmm

66

-

-

... More
Supplying and making water proof joint with heat shrinkable joint kit including copper ferrules for following size of 3 core submersible copper conductor cable of 1.1 KV grade as per specification. 23.15.2 3x2.5 sqmm

2

-

-

... More
3x4.0 sqmm

2

-

-

... More
Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp.

180

-

-

... More
Repair of submersible motor parts 100 mm dia meter opening /Rewinding and assembly with testing etc complete and reinstallation including etc 23.19.1 Rewinding of motor from 3 to 5 HP (3 phase) waterproof copper winding wir

1

-

-

... More
Rewinding of motor from 2 HP (3 phase) waterproof copper winding wire

1

-

-

... More
Gun metal motor bearing bush

1

-

-

... More
Bearing housing upper

2

-

-

... More
Bearing housing Lower

2

-

-

... More
Revolving thrust Disc

4

-

-

... More
M.S. motor base

3

-

-

... More
S.S. coupling & key set

2

-

-

... More
Surcleap

4

-

-

... More
Nut-bolt, strut washer & packing materials etc. complete.

8

-

-

... More
Stainless steel rotor sleeve

2

-

-

... More
Repairing of control panel board with replacement of contactor kit set capacitors, boost up, condenser etc complete including wiring, fitting, and testing. 23.23.1 Single phasing preventer

1

-

-

... More
Replacement of overload relay unit set up to 15amp. Suitable with existing control panel board

1

-

-

... More
Replacement of Amp. Meter with fitting and testing complete.

1

-

-

... More
Replacement of Volt meter with fitting & testing complete.

2

-

-

... More
TPN MCB with box up to 32 amp. i/c fitting & testing complete.

1

-

-

... More
Providing and replacing set of 3 nos wiremesh and 3 Nos wood wool/ Khas pads of size upto 55cm x 75cm (NS) of air coolar etc complete.

7

-

-

... More
Repainting of air cooler by scraping of old paint, making surface even, painting with red oxide primer & two coats of enamel paint of required shade complete.

3

-

-

... More
Providing and replacing burnt/ damaged with new water pump in existing air cooler etc complete.

8

-

-

... More
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification.

12

-

-

... More
Rewinding of ceiling fan by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.1.1 48” (1200 mm sweep )

166

-

-

... More
56” (1400 mm sweep )

16

-

-

... More
Rewinding of Ex-Fan motor by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.2.1 12” (300mm) Ex. Fan

57

-

-

... More
15” (380mm) Ex. Fan

12

-

-

... More
18” (450mm) Ex. Fan

3

-

-

... More
Cleaning, overhauling, servicing of ceiling/ Exhaust / wall bracket fan including greasing/ oiling, replacement of safety pins, check nuts, lock nut, nut bolts etc. making perfect alignment inluding dismentaling and refitting at site as per specification.

25

-

-

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of ceiling fan including dismentaling, disambling, assembling and reiftting as per specification.

19

-

-

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of exhaust fan including dismentaling, disambling, assembling and reiftting as per specification.

13

-

-

... More
Supplying and replacing defective 2/3 KW heating element with approved make and suitable size in existing water heater/Gyser of any make, any capacity.

6

-

-

... More
Supplying and replacing defective thermostat with approved make and suitable size in existing water heater/Gyser of any make, any capacity.

6

-

-

... More
Painting of ceiling fan in installed position with one or more coat of spray painting with synthetic enamel paint of approved brand and make to give an even shade including cleaning the surface with detergent as per specification.

18

-

-

... More
Painting of following height steel tubular poles with two coat of enamel paint of approved brand and colour including cleaning the surface as per specification: 31.11.2 Above 6 metre and upto 8 metre

6

-

-

... More
Above 8 metre and upto 10 metre

6

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

38

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

302

-

-

... More
Supply of "H" beam steel pole as per IS specifications in standard length for over head line work: 19.1.2 "H" beam steel pole 152x152x7x12 mm standard weight 37.1 kg /metre

11

-

-

... More
Supply of steel R.S. JOIST as per IS specifications in standard length for over head line work: 19.2.2 Designation ISMB175 size 175x90x8.6x5.5mm weight 19.3 kg /metre

9

-

-

... More
Erection of STEEL TUBULAR or "H" BEAM/ ISMB pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation and cement concrete collar of size 0.4 metre dia and 0.50 metre height from ground level including excavation and refilling etc. as per specification of length: 19.10.4 7 metre to 10 metre

77

-

-

... More
11 metre to 12 metre

79

-

-

... More
13 metre to 14 metre

9

-

-

... More
Erection of steel tubular or "H beam POLE STRUT in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and securing with holding clamps, bolts and nuts etc. as per specification:

40

-

-

... More
Supply and fixing following overhead line accessories. 20.1.1 Stay rod (19/20mm dia 1.8 metre long) with anchor plate 300x300x6.4mm in CC

16

-

-

... More
Stay wire 7/4.0mm dia

124

-

-

... More
Stay wire 7/3.15mm dia

98

-

-

... More
MV Strain insulator

12

-

-

... More
Bow tightener

8

-

-

... More
MV Shackle insulator 75x90mm with G.I. bolts and nuts

76

-

-

... More
DC cross arm made of MS channel 100x50x5 mm @ 9.56 kg/m

14

-

-

... More
Supplying and erection of stay set complete (galvanized) with 19/20mm dia x 1.8 metre long stay rod, anchor plate of size 300mm x 300mm x 6.4 mm, thimble stay clamps, turn buckle (19/20mm x 600mm), strain insulator and specified G.I. stay wire etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as per specification. 20.2.1 With 7/4.00 mm dia G.I. stay wire

42

-

-

... More
With 7/3.15 mm dia G.I. stay wire

32

-

-

... More
Supplying and erection of channel iron 75x40x4.8 mm (7.14kg/m) cross arm for overhead line complete with clamps, bolts and nuts including drilling of holes for insulator pins, bolts and nuts etc as per specification. 20.7.2 For 4 wire overhead line (1.15m long)

16

-

-

... More
Supplying and erection of angle iron 50x50x6.0 (4.5kg/m) cross arm for overhead line complete with clamps, bolts and nuts including drilling of holes for insulator pins, bolts and nuts etc as per specification. 20.9.2 For 4 wire overhead line (1.15m long)

8

-

-

... More
Supplying and erection of shackle insulator with G.I. bolts, nuts and straps etc. as per specification. 20.11.1 Size 75mm x 90mm

48

-

-

... More
Supplying and fixing guard insulator or split insulator complete 20.15.1 25x25 mm

25

-

-

... More
Supplying and erection of MV horn gap lightening arrester.

16

-

-

... More
Supplying and fixing approved make 11 KV glazed porcelain pin insulator with G.I. spindle on existing pole bracket with necessary materials as per specification:

79

-

-

... More
Supplying and fixing approved make 11 KV glazed porcelain disc type insulator with tension hardware on existing pole/ support/ cross arm channel as per specification complete:

32

-

-

... More
Supplying and erection of 11 KV gang operated air break switch on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.

13

-

-

... More
Supplying and erection of 11 KV D.O. fuse unit on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.

9

-

-

... More
Supplying and fixing approved make 33 KV glazed porcelain pin insulator with G.I. spindle on existing pole bracket with necessary materials as per specification:

9

-

-

... More
Supplying and fixing approved make 33 KV (3x11KV) glazed porcelain disc type insulator with tension hardware on existing pole/ support/ cross arm channel as per specification complete:

9

-

-

... More
Supplying and erection of 33 KV gang operated air break switch on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.

11

-

-

... More
Supplying and erection of 33 KV D.O. fuse unit on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.

7

-

-

... More
Supplying and erection of G.I wire of size 8 SWG to 4 SWG including binding etc. as per specification.

214

-

-

... More
Supply and erection standard ACSR (aluminium conductor steel reinforced) confirming to IS 398-1961 of approved make at existing insulator at height upto 14m from ground level including stringing, binding with insulator, jointing wherever required, jumpering, tearing off connection etc complete etc. as per specification including clearing off obstacle if any: 20.32.1 Squirrel 6/1/2.11mm dia with calculated aluminium area 20.98 sq.mm, weight 85 kg/ km (50 amps)

2

-

-

... More
Weasel 6/1/2.59mm dia with calculated aluminium area 31.61 sq.mm , weight 128 kg/ km (80 amps)

29.64

-

-

... More
Rabbit 6/1/3.35mm dia with calculated aluminium area 52.88 sq.mm, weight 214 kg/ km (100 amps)

4.3

-

-

... More
Raccoon 6/1/4.09mm dia with calculated aluminium area 78.83 sq.mm , weight 319 kg/ km (198 amps)

1

-

-

... More
Dog 6/4.72(AL), 7/1.57(S) mm dia with calculated aluminium area 105 sq.mm , weight 394 kg/ km (248 amps)

1

-

-

... More
Supplying and erection DANGER BOARD made MS sheet duly painted and maked as per IE rules and specification.

104

-

-

... More
Supply and errection of following Polymer Insulator with G.I. Bolt, Nuts and Straps etc. as per specification. 20.34.1 33 KV Composite Disc Insulator

68

-

-

... More
33 KV Polymer Disc Insulator {45kN}

6

-

-

... More
11 KV Disc Insulator

86

-

-

... More
33 KV Pin Insulator with Pin

98

-

-

... More
11 KV Pin Insulator with Pin

98

-

-

... More
Dismantling of angle iron board/ cubical panel including repairing the wall, shifting of dismantled material to department store. (front area to be measured)

19

-

-

... More
Dismantling of steel pole, R. S. joist, girder pole from the cement concrete foundation with bracket, insulators, stay wires etc, refilling the pit upto ground level including shifting of dismantled material to department store.

19

-

-

... More
Dismantling of stay set from the cement concrete foundation, refilling the pit upto ground level including shifting of dismantled material to department store.

37

-

-

... More
Providing and laying Cast-in-situ cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm including mixing with mechanical mixer, compacting with vibrator, finishing and currying etc. complete but excluding form work.

98.65

-

-

... More
Painting new steel and other metallic surface with red oxide zinc chromide primer paint complete with supply of material labour etc. including preparation of surface.

49

-

-

... More
Painting wood steel and other metallic surface with Aluminium Paint complete with material and labour including preparation of surface.

49

-

-

... More
Supply & Fixing Earthing Coil 8 SWG GI Wire 50 MM Dia 450 M

76

-

-

... More
Supply & Fixing of LT Five Pin Cross Arm - 50 X 50 X 6 mm

131

-

-

... More
Supply & Fixing of RCC Block (with 6 mm MS Bar)

5

-

-

... More
Supply & Fixing of 11 KV Guarding Channel - 100 X 50 mm

12

-

-

... More
Supply & Fixing of Jointing Sleeve for Raccoon Conductor

9

-

-

... More
Supply & Fixing of Jointing Sleeve for Weasel,Squirrel & Rabbit Conductor.

5

-

-

... More
S/F of M.S. Nuts & Bolts - 12 X 65 mm / 12 X 100 mm /16 X 40 mm

160

-

-

... More
S/F of M.S. Nuts & Bolts - 16 X 65 mm / 16 X 90 mm

130

-

-

... More
S/F of M.S. Nuts & Bolts - 16 X 200 mm / 16 X 250 mm /16 X 300 mm / 20 X 75 mm / 20 X 90 mm / 20 X 110 mm / 24 X 120 mm / 16 X 100 mm / 16 X 140 mm / 16 X 160 mm

185

-

-

... More
Supply & Fixing of 11 KV Cut Point Channel

20

-

-

... More
Supply & Fixing of Transformer Mounting Channel - 100 X 50 mm

26

-

-

... More
Supply & Fixing of 11 KV Strain Hardware fitting

129

-

-

... More
Supply & Fixing of I bolt M - 20 X 128 mm Thread Portion 50 mm

14

-

-

... More
Supply & Fixing of 33 KV Strain Hardware fitting

46

-

-

... More
Supply & Fixing of 33 KV "V " Cross Arm

7

-

-

... More
Supply & Fixing of 33 KV Top Clamp

7

-

-

... More
Supply & Fixing of 11 KV Top Clamp

33

-

-

... More
Supply & Fixing of 11 KV "V " Cross Arm

29

-

-

... More
Supply & Fixing of 11 KV 4' Centre DC Cross Arm

1

-

-

... More
Supply & Fixing of 11 KV 8' Centre DC Cross Arm

10

-

-

... More
Supply & Fixing of 11 KV D.O./LA Mounting Channel 75 X 40 mm.

10

-

-

... More
Supply & Fixing of Aluminium Bobbin

14

-

-

... More
Supply & Fixing of 33 KV Guarding Channel - 100 X 50 mm

28

-

-

... More
Supply & Fixing of 1 C 16 sqmm Cable

4

-

-

... More
Supply & Fixing of 1 C 50 sqmm Cable

3

-

-

... More
Supply & Fixing of Distribution Box for 63 KVA Transformer (200A, Isolator & 6 SP MCCB of 100 A)

9

-

-

... More
Supply & Fixing of SMC LT Distribution Box for 100 KVA Distribution Transformer

2

-

-

... More
Supply & Fixing of 33 KV DC Cross Arm 5' Centre 100 X 50 mm M.S. Channel

16

-

-

... More
Distibution box 3 Phase 4 Connectors

5

-

-

... More
Suspension clamp assembly ( Consisting of GI pole Clamp, GI Flat type I-hook & Nylon Cable tie)

6

-

-

... More
Anchor clamp assembly ( Consisting of GI pole Clamp, GI Flat type I-hook & Nylon Cable tie)

3

-

-

... More
Supply & Fixing of Pole Clamp

30

-

-

... More
Supply & Fixing of Strain Plate

6

-

-

... More
LT AB Cable 3 X 70 + 1 X 16(Street Light) + 1 X 5

1

-

-

... More
GRAND TOTAL

-

-

-

... More
Say In Rs.

-

-

-

... More
Sub Divisional Officer PWD (E/M) Sub Division Dhamtari(C.G.)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.