Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Opening Date20 Jan 2025
Closing Date4 Feb 2025
Tender Amount₹ 44,72,044.43 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
205mmX94mm (6 Module)

62

178

11036

... More
8 Module

43

216

9288

... More
12 Module

39

258

10062

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 4.4.1 75mmX75mm (1/2 Module)

14

99

1386

... More
100mmX75mm (3 Module)

11

129

1419

... More
125mmX75mm (4 Module)

12

141

1692

... More
200mmX75mm (6 Module)

8

186

1488

... More
125mmX125mm (8 Module)

7

226

1582

... More
200mmX150mm (12 Module)

10

266

2660

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 4.5.1 1 Module

27

48

1296

... More
3 Module

42

58

2436

... More
4 Module

39

65

2535

... More
6 Module

31

84

2604

... More
8 Module

56

101

5656

... More
12 Module

25

134

3350

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.1 5/6 amps one way switch

80

69

5520

... More
5/6 amps two way switch

91

85

7735

... More
Bell push

27

80

2160

... More
15/16 amp switch

100

89

8900

... More
3 pin 5/6 amp socket outlet

92

96

8832

... More
6 pin 15/16 amp socket outlet

88

120

10560

... More
Fan regulator (one module size) electronic stepped type moving all rounds

66

186

12276

... More
Fan regulator (two module size) electronic stepped type moving all rounds

72

223

16056

... More
Plug Top (Deluxe type) 3 pin 5/6 Amps (For light plug).

81

72

5832

... More
Plug Top (Deluxe type) 3 pin 16 Amps (For power plug).

59

85

5015

... More
RJ-45 {CAT6} socket outlet

17

263

4471

... More
RJ-45 {CAT6} LAN, I/O Box

12

199

2388

... More
Telephone socket outlet

14

70

980

... More
T.V. antenna socket outlet

11

74

814

... More
Computer Outlet Jack

8

242

1936

... More
25/32 amp A.C. Starter switch

30

246

7380

... More
Ceiling rose 3 pin 5 amp

97

40

3880

... More
Batten/ angle holder

91

41

3731

... More
Providing and fixing 16/32 amp DP surface switch with neon on suitable size wooden box including connection, testing etc. complete.

12

152

1824

... More
Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification.

35

816

28560

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.1 Ordinary (simple)

17

74

1258

... More
Deluxe

22

107

2354

... More
Providing and fixing following size FRLS PVC insulated, PVC sheathed, flexible copper conductor wire on the floor/ wall, or side of the table/ door etc. as per specification. 5.8.1 0.5 sq. mm two core

561

21

11781

... More
1.0 sq. mm two core

468

27

12636

... More
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification.

60

42

2520

... More
Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification.

34

109

3706

... More
Providing and fixing fan clamp made of 3mm thick MS flat on existing iron trusses/ girder including necessary bolts and nuts etc. as per specification.

39

40

1560

... More
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11.1 45 cm long

10

31

310

... More
90 cm long

6

58

348

... More
300 cm long

9

140

1260

... More
Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan)

141

56

7896

... More
Supplying and fixing of resistance type ceiling fan regulator, in/ on existing switch box including connection, earthing etc. as per specification.

29

97

2813

... More
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt {4 feet}

157

443

69551

... More
Supplying, installation, testing and commissioning of following surface/ concealed type fluorescent fitting (luminaries) complete with electronic ballast/ copper ballast glow type starter but without fluorescent lamp, on ceiling/ wall surface, earthing the fitting etc. as per specification. P.F. should be greater than 0.9. 6.30.1 4' x 40 W single patti type

239

215

51385

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts electronic ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9. 6.33.1 For 36/40 watt T8 flu. Fitting

81

235

19035

... More
For 28 watt T5 flu. Fitting

88

367

32296

... More
For 26 watt CFL Fitting

92

518

47656

... More
For 36 watt CFL Fitting

100

518

51800

... More
Supplying, fixing, testing and commissioning of glow type starter suitable for 36/40 watt T8 230/250 volts flu. lamp in existing luminaries at all locations as per specification.

84

15

1260

... More
Supplying, fixing, testing and commissioning of following 230/250 volts igniters in existing luminaries at all locations as per specification. P.F. should be greater than 0.9. 6.37.1 For 70-400 watt integral luminaries

48

326

15648

... More
For 70-400 watt non integral luminaries

44

236

10384

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors in existing ceiling fans/ exhaust fan at all locations as per specification. P.F. should be greater than 0.9. 6.38.2 2.5 MFD

70

113

7910

... More
3.15 MFD

64

114

7296

25

116

2900

... More
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors for single phase motor at all locations as per specification. P.F. should be greater than 0.9 6.39.2 8 MFD

11

121

1331

... More
10 MFD

9

136

1224

... More
12 MFD

7

142

994

... More
15 MFD

10

147

1470

... More
25 MFD

8

186

1488

... More
30 MFD

5

195

975

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated , copper conductor, single core wire, earthing etc. complete as per specification.

16

71

1136

... More
Installation, testing and commissioning of wall/ cabin fan, etc. complete as per specification.

10

45

450

... More
Installation of following size exhaust fan in the existing opening including connection, testing, commissioning etc. as per specification. 6.42.1 Upto 300 mm sweep

7

130

910

... More
380 mm sweep

5

130

650

... More
450 mm sweep

4

198

792

... More
Extra for fixing the louvers/ shutters complete with frame for exhaust fan of all sizes.

7

89

623

... More
Erection of all type of GLS lamps/ CFL/LED fitting on wall /ceiling of all sizes and all shapes complete with all accessories including connection etc. as per specification.

99

45

4455

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. including connection with 1.5 sq. mm FRLS PVC insulated , copper conductor, single core wire and earthing etc. as per specification. 6.45.1 Directly on ceiling/ wall

77

58

4466

... More
Installation, testing and commissioning of all types of street light fittings with all accessories and lamps on street light bracket fixed on wall/ pole, including connection with FRLS PVC insulated , copper conductor, single core wire upto 2 metre length, earthing etc. as per specification.

2

85

170

... More
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as per specification.

20

10

200

... More
Providing and fixing wooden board of suitable size (18''x 24'') for energy meter etc complete as per specification.

5

123

615

... More
Supplying , installation , testing and commissioning of low maintenance tubular battery with necessary connectors, links terminals etc. 12Volts DC 18 AH

6

1937

11622

... More
Supplying , installation , testing and commissioning of Battery charger charging unit with battery overcharge protection, battery deep discharge protection, reverse polarity protection, etc. complete

6

614

3684

... More
Fabrication and installation of angle iron including angle size 50 mm x 5 mm thick with labour charges including materials as per specification

54

66

3564

... More
Supply, Installation, testing and commissioning of following type LED Driver for LED Panel/down lights by approved make as required. 6.65.1 3-6 watt

30

126

3780

... More
9-12 watt

69

154

10626

... More
18/20 watt

92

194

17848

... More
Supply, Installation, testing and commissioning of following type LED Driver for COB lights by approved make as required. 6.66.1 6-15 watt

7

433

3031

... More
18/20 watt

6

451

2706

... More
40 watt

9

625

5625

... More
Supplying , Installation, testing and commissioning of following type LED Driver for LED Street lights / Flood Lights, IP 65 by approved make as required. 6.68.1 10 watt

11

351

3861

... More
24 watt

10

431

4310

... More
36 watt

16

508

8128

... More
50 watt

6

613

3678

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point

32

266

8512

... More
Medium Point

54

424

22896

... More
Long Point

72

588

42336

... More
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

22

420

9240

... More
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

27

216

5832

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.1 Short Point

18

442

7956

... More
Medium Point

19

659

12521

... More
Extra Long Point I

21

1302

27342

... More
Extra Long Point III

24

1995

47880

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.1 Short Point

17

589

10013

... More
Long Point

15

1350

20250

... More
Extra Long Point I

16

1807

28912

... More
Extra Long Point II

18

2315

41670

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.12.2 Medium Point

17

1171

19907

... More
Long Point

15

1705

25575

... More
Extra Long Point I

13

2326

30238

... More
Extra Long Point III

16

3708

59328

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1 3 X 1.5 sq. mm in 20mm conduit

292

92

26864

... More
3 X 2.5 sq. mm in 20mm conduit

196

111

21756

... More
6 X 2.5 sq. mm in 25mm conduit

178

172

30616

... More
9 X 2.5 sq. mm in 32mm conduit

90

238

21420

... More
12 X 2.5 sq. mm in 32mm conduit

87

288

25056

... More
3 X 4 sq. mm in 25mm conduit

138

145

20010

... More
3 X 6 sq. mm in 25mm conduit

147

182

26754

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 1.15.2 25 mm

130

53

6890

245

59

14455

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.7.1 Short Point

23

227

5221

... More
Medium Point

57

347

19779

... More
Long Point

48

465

22320

... More
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

16

337

5392

... More
Extra for providing and fixing light plug point on board in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

24

222

5328

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.10.1 Short Point

19

427

8113

... More
Medium Point

17

601

10217

... More
Extra Long Point I

20

1210

24200

... More
Extra Long Point II

18

1555

27990

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.11.1 Short Point

19

518

9842

... More
Long Point

20

1157

23140

... More
Extra Long Point I

17

1585

26945

... More
Extra Long Point III

18

2492

44856

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 3 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.12.1 Short Point

20

638

12760

... More
Long Point

18

1513

27234

... More
Extra Long Point I

19

2105

39995

... More
Extra Long Point III

15

3374

50610

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.13.1 3 X 1.5 sq. mm in 20mm conduit

221

67

14807

... More
3 X 2.5 sq. mm in 20mm conduit

258

87

22446

... More
6 X 2.5 sq. mm in 25mm conduit

230

155

35650

... More
9 X 2.5 sq. mm in 32mm conduit

175

218

38150

... More
12 X 2.5 sq. mm in 32mm conduit

87

268

23316

... More
3 X 4 sq. mm in 25mm conduit

192

128

24576

... More
3 X 6 sq. mm in 25mm conduit

86

166

14276

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 2.15.2 25 mm

129

39

5031

184

51

9384

... More
Supplying and fixing of following sizes PVC casing caping along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5). 2.16.2 25x16 mm

220

30

6600

... More
32x16 mm

186

32

5952

... More
Wiring for light point/ exhaust fan point/ call bell point with 3x1.5 sq. mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing 5/6 amp modular type switch, modular base and cover plate etc. as per specification and IS: 694 (2010) 3.6.1 Short Point

12

205

2460

... More
Medium Point

11

278

3058

... More
Long Point

9

349

3141

... More
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface/ concealed, Steel/FRLS PVC conduit and providing and fixing 5/6 amp modular type switch, modular base and cover plate etc. as per specification and IS: 694 (2010)

14

269

3766

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing modular type 6 Amp switch and 3 pin 6 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.8.1 Short Point

16

340

5440

... More
Medium Point

11

499

5489

... More
Extra Long Point II

13

1184

15392

... More
Extra Long Point III

8

1448

11584

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) and providing and fixing modular type 16 Amp switch and 6 pin 16 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.9.1 Short Point

10

431

4310

... More
Long Point

8

937

7496

... More
Extra Long Point II

11

1677

18447

... More
Extra Long Point III

6

2067

12402

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed Steel/FRLS PVC conduit and providing and fixing modular type 32 Amp SP MCB "C" curve and 3 pin 20 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.10.1 Short Point

11

563

6193

... More
Long Point

8

1332

10656

... More
Extra Long Point I

6

1865

11190

... More
Extra Long Point III

9

3048

27432

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.2 2 x 1.5 sq. mm

122

26

3172

... More
3 x 1.5 sq. mm

158

37

5846

... More
3 x 2.5 sq. mm

49

57

2793

... More
3 x 4 sq. mm

170

82

13940

... More
3 x 6 sq. mm

125

122

15250

... More
Supplying and drawing following pair 0.5 mm FR PVC insulated copper conductor, unarmored telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification. 3.12.1 1 Pair

78

8

624

... More
2 Pair

50

11

550

... More
4 Pair

98

17

1666

... More
Supplying and drawing following grade co-axial TV wire FR PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed Steel/FRLS PVC conduit as per specification. 3.13.1 RG-6 grade

45

14

630

... More
RG-11 grade

61

27

1647

... More
Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification

272

19

5168

... More
Supplying and drawing following pair 0.5 mm FR PVC insulated stranded copper conductor armoured telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 3.15.1 10 Pair

30

67

2010

... More
20 Pair

34

165

5610

... More
Providing and replacing set of 3 nos wiremesh and 3 Nos wood wool/ Khas pads of size upto 55cm x 75cm (NS) of air coolar etc complete.

67

212

14204

... More
Repainting of air cooler by scraping of old paint, making surface even, painting with red oxide primer & two coats of enamel paint of required shade complete.

48

312

14976

... More
Providing and replacing burnt/ damaged with new water pump in existing air cooler etc complete.

44

199

8756

... More
Providing installation testing and commissioning of 12U Indoor Rack Wallmount 12U 450D With Front Glass Door Lock & Key 550 12U - (Fan, cable manager, PDU included) complete as required.

5

5220

26100

... More
Supply, installation and testing for HDMI cable.

76

462

35112

... More
Supply installation and testing for VGA cable.

32

379

12128

... More
Supplying , installation , Testing and Commissioning of 2.5Sq.mm Speaker cable Cross sec Area 1.5 sqmm, No of Strands 75 , Size of Strands 34 , Cond.Type ATC Speaker Cable - Copper 2Core, Twisted, Tin Coated, Shielded 2.5SQMM (70/.2) ATC 2/C SPEAKER CABLE 14AWG with all necessery terminals and Connectors.

96

468

44928

... More
Supplying , installation , Testing and Commissioning of Heavy Microphone Cable AWG NOM Insulation Dia. Shield NOM NOM Conductor Center Inches mm Construction Jacket Dia. Capacitance Resistance Canductor (Min.) Inches mm (Pf / mtr.) Ohm / km (Max.) 24 AWG 0.053 1.35 80% 0.232 5.9 68(Cond. To Cond.) 91.1 with all necessery terminals and Connectors.

124

468

58032

... More
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification.

17

168

2856

... More
Rewinding of ceiling fan by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.1.1 48” (1200 mm sweep )

551

349

192299

... More
Rewinding of Ex-Fan motor by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.2.1 12” (300mm) Ex. Fan

67

384

25728

... More
18” (450mm) Ex. Fan

76

432

32832

... More
Cleaning, overhauling, servicing of ceiling/ Exhaust / wall bracket fan including greasing/ oiling, replacement of safety pins, check nuts, lock nut, nut bolts etc. making perfect alignment inluding dismentaling and refitting at site as per specification.

148

97

14356

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of ceiling fan including dismentaling, disambling, assembling and reiftting as per specification.

216

80

17280

... More
Replacement of defective ball bearing by approved make of suitable size bearing of all size of exhaust fan including dismentaling, disambling, assembling and reiftting as per specification.

324

84

27216

... More
Supplying and replacing defective 2/3 KW heating element with approved make and suitable size in existing water heater/Gyser of any make, any capacity.

12

184

2208

... More
Supplying and replacing defective thermostat with approved make and suitable size in existing water heater/Gyser of any make, any capacity.

14

187

2618

... More
Painting of ceiling fan in installed position with one or more coat of spray painting with synthetic enamel paint of approved brand and make to give an even shade including cleaning the surface with detergent as per specification.

214

61

13054

... More
Painting of following height steel tubular poles with two coat of enamel paint of approved brand and colour including cleaning the surface as per specification: 31.11.1 upto 6 metre

9

91

819

... More
Above 8 metre and upto 10 metre

10

233

2330

... More
Painting new steel and other metallic surface with red oxide zinc chromide primer paint complete with supply of material labour etc. including preparation of surface.

40

116

4640

... More
Supplying and fixing wall/ floor mounted metal board of welded construction, fabricated with minimum 50mmX 50mm X 6mm angle iron frame work, with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gears including painting etc. as per specification.

4

3025

12100

... More
Supplying and fixing wall mounted metal board of welded construction, fabricated with minimum 35 mm X 35 mm X 6 mm angle iron frame work, with 25 mm X 6 mm flat iron as intermediate members including painting etc. as per specification.

5

2861

14305

... More
Supplying and fixing metal clad busbar chamber with 2 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.7.1 100 amps x 300mm long

7

1117

7819

... More
100 amps x 450mm long

6

1621

9726

... More
Providing and fixing metal clad, SP&N switch fuse unit (re-wirable), 230/250 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.9.1 32 amps

8

978

7824

... More
63 amps

5

1762

8810

... More
Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.10.1 32 amps

9

926

8334

... More
63 amps

6

1915

11490

... More
100 amps

8

3493

27944

... More
200 amps

4

5420

21680

... More
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.2 32 amps

10

90

900

... More
63 amps

8

162

1296

... More
100 amps

4

290

1160

... More
300 amps

6

797

4782

... More
Providing and making interconnection in cubical panel between BBC and switchgears with following size FRLS PVC insulated copper conductor wire lead of length upto 50cm including providing copper thimbles on both ends as per specification (To be measured separately for each phase/ neutral). 7.17.1 10 sqmm (32 amp)

5

76

380

... More
16 sqmm (63 amp)

4

104

416

... More
35 sqmm (125 amps)

7

181

1267

... More
Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 7.18.3 40x5mm (300 amps)

6

465

2790

... More
50x5mm (400 amps)

5

567

2835

... More
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.2 Above 300 mm and upto 450 mm deep

10

7525

75250

... More
Above 450 mm and upto 600 mm deep

8

8519

68152

... More
750 mm deep

6

9044

54264

... More
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.20.1 100 amp (20x5mm)

6

717

4302

... More
200 amp (30x5mm)

4

907

3628

... More
300 amp (50x5mm)

5

1336

6680

... More
400 amp (50x6mm)

3

1531

4593

... More
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.21.1 100 amp (20x3mm)

8

1319

10552

... More
200 amp (25x5mm)

5

2382

11910

... More
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.3 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA

4

2385

9540

... More
3 pole MCCB, 125A, Adjustable Thermal - Magnetic Release, 25KA

8

5740

45920

... More
3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA

7

12006

84042

... More
3 pole MCCB, 250A, Adjustable Thermal - Magnetic Release, 35KA

5

13060

65300

... More
3 pole MCCB, 320A, Adjustable Thermal - Magnetic Release, 35KA

4

13933

55732

... More
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.2.1 4 way, Single door

6

567

3402

... More
4 way, Double door

6

784

4704

... More
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.1 4 way Single door

5

1317

6585

... More
4 way Double door

4

1716

6864

... More
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1 6 amps to 32 amps

37

151

5587

... More
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 6 amps to 32 amps

22

148

3256

... More
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.12.2 6 amps to 32 amps

16

411

6576

... More
63 amps

10

643

6430

... More
Supplying and fixing TP MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.14.2 6 amps to 32 amps

8

667

5336

... More
63 amps

11

996

10956

... More
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.2 63 amps

12

621

7452

... More
100 amps

6

647

3882

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.22.3 63 amps

4

2329

9316

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as per specification.

10

7

70

... More
Supplying and fixing sheet steel enclosure of suitable size made of 1.6mm thick CRCA MS sheet, for 100 amps MCCB on existing metal board/ wall including painting etc as per specification.

12

434

5208

... More
Supplying and fixing Low voltage (class -II) surge protection device (SPD) TP&N 440 volts, in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.

7

8251

57757

... More
Providing and fixing metal clad, 4 pole, on load change over switch unit (with sheet steel enclosure), 415/500 volts, in cubicle panel including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. (Connecting lead if required shall be paid separately) 10.7.1 63 amps

4

5283

21132

... More
100 amps

5

6726

33630

... More
Providing and fixing 2 pole, 230/250 volts following rating power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 10.12.2 32 amps

6

526

3156

... More
63 amps

4

674

2696

... More
Providing and fixing 3 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 10.13.3 60 amps

5

3261

16305

... More
100 amps

4

6774

27096

... More
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.2 100/5 amps

14

349

4886

... More
200/5 amps

12

347

4164

... More
315/5 amps

10

356

3560

... More
Providing and fixing single phasing preventer in existing panel including connection, testing and commissioning as per specification.

11

409

4499

... More
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.

48

94

4512

... More
Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification

12

975

11700

... More
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.20.1 Analog type

11

397

4367

... More
Digital type

10

835

8350

... More
Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.21.1 For voltmeter

5

189

945

... More
For ammeter

4

207

828

... More
Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification. 10.22.1 Digital type

5

1901

9505

... More
Analoge type

6

2525

15150

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

3

6209

18627

... More
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification.

25

77

1925

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

18

513

9234

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

15

36

540

... More
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

16

94

1504

... More
Excavation for foundation in soft soil/hard soil including dressing of sides and ramming of bottoms, lifting and getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres

18

168

3024

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.3.23 4 x 16 sq. mm.

256

103

26368

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing masonry open duct as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.4.12 3.5 x 35 sq. mm.

77

126

9702

... More
3.5 x 70 sq. mm.

45

240

10800

... More
3.5 x 120 sq. mm.

69

372

25668

... More
3.5 x 150 sq. mm.

82

475

38950

... More
3.5 x 300 sq. mm.

74

987

73038

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 15.23.12 3½ X 25 sq. mm (25 mm)

92

104

9568

... More
3½ X 35 sq. mm (28 mm)

46

153

7038

... More
3½ X 50 sq. mm (32 mm)

37

168

6216

... More
3½ X 70 sq. mm (35 mm)

28

199

5572

... More
3½ X 95 sq. mm (38 mm)

33

256

8448

... More
3½ X 120 sq. mm (45 mm)

26

283

7358

... More
3½ X 150 sq. mm (45 mm)

11

318

3498

... More
3½ X 300 sq. mm (63 mm)

14

616

8624

... More
4 X 16 sq. mm (22 mm)

32

101

3232

... More
Designing & Providing of suitable RCC trench in cement concrete 1:3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) for laying of cable inground including execavation, steel reinforcement (minimum 35.75 kg per cum), 4" drain wall, drain cover, frame work, curing & refilling of excavated soil etc as per specification.

6

3794

22764

... More
Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification. 23.6.1 32 mm outer dia

99

55

5445

... More
50 mm outer dia

97

118

11446

... More
63 mm outer dia

88

190

16720

... More
Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as per specification. 23.7.2 80 mm dia.

4

2345

9380

... More
50 mm dia.

5

1058

5290

... More
32 mm dia.

7

526

3682

... More
25 mm dia.

4

455

1820

... More
Supplying and fixing of following sizes GM non return valve ISI mark in the suction/ delivery line etc. as per specification. 23.8.2 80 mm dia.

4

2949

11796

... More
50 mm dia.

5

1246

6230

... More
32 mm dia.

4

623

2492

... More
25 mm dia.

5

444

2220

... More
Supply, installation, testing and commissioning of 5-7.5 HP 3 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 5/7.5 HP 3 phase DOL starter with over load and no volt relay 1 No c) 32 A "C" curve TPMCB 1 No d) Voltmeter 0-500 V with selector switch 1 set e) Ammeter 0-10 A with CT's and selector switch 1 set.

5

4152

20760

... More
Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set

6

4030

24180

... More
Supplying and fixing M.S. clamp 50 cm long made of 50mmx5mm thick M.S. Flat for holding the pipes and submerable pump set as per specification.

10

291

2910

... More
Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification

16

388

6208

... More
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 23.14.2 3x2.5 sqmm

114

64

7296

... More
3x4.0 sqmm

60

90

5400

... More
3x6.0 sqmm

98

135

13230

... More
Supplying and making water proof joint with heat shrinkable joint kit including copper ferrules for following size of 3 core submersible copper conductor cable of 1.1 KV grade as per specification. 23.15.1 3x1.5 sqmm

14

260

3640

... More
3x2.5 sqmm

8

261

2088

... More
3x4.0 sqmm

6

264

1584

... More
3x6.0 sqmm

7

450

3150

... More
Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp.

488

16

7808

... More
Repair of Openwell Motor Parts and submersible motor parts 150 mm dia by opening/ rewinding and assembly with testing and reinstallation including etc of motor from 3 to 5 HP (3 phase) 23.17.1 Rewinding of motor from 3 to 5 HP (3 phase) water proof copper winding wire

7

1833

12831

... More
Oil seal/water seal/mechanical seal/rubber parts

5

177

885

... More
Gun metal motor bearing bus (36x50x40 to 38x50x40 size)

4

189

756

... More
Gun metal thrust bearing Axle

7

403

2821

... More
Bearing housing upper

8

411

3288

... More
Bearing housing Lower

5

433

2165

... More
Revolving thrust Disc

9

309

2781

... More
M.S. motor base

6

422

2532

... More
Stainless steel rotor sleeve

6

195

1170

... More
Rotor 3 to 5 HP

5

2973

14865

... More
Repair of openwell pump parts and submersible pump parts 150 mm dia meter by opening and replacing defective part with compatible new part and assembly it with testing and re-installation including etc 23.18.1 Stainless steel bearing sleeve

10

161

1610

... More
Gun metal/ stainless steel impellers

8

290

2320

... More
Gun metal/ stainless steel diffusers

6

282

1692

... More
Gun metal/ stainless steel neck ring

11

256

2816

... More
Gun metal/ stainless steel Bowl set

7

205

1435

... More
Gun metal/ stainless steel surcleap

9

195

1755

... More
Stainless steel pump shaft

6

630

3780

... More
Gun metal bush

5

195

975

... More
Stainless steel sleeve

11

119

1309

... More
Gun metal/ stainless steel sand guard

4

207

828

... More
Nut-bolt, strut washer & packing materials etc. complete.

5

388

1940

... More
Stainless steel coupling & key set

7

347

2429

... More
NRV suitable for pumpset

11

350

3850

... More
Pump tee patti

8

144

1152

... More
Suction housing

7

358

2506

... More
Repair of submersible motor parts 100 mm dia meter opening /Rewinding and assembly with testing etc complete and reinstallation including etc 23.19.1 Rewinding of motor from 3 to 5 HP (3 phase) waterproof copper winding wire

7

2355

16485

... More
Rewinding of motor from 2 HP (3 phase) waterproof copper winding wire

5

2311

11555

... More
Rewinding of motor upto 2 HP (single phase) waterproof copper winding wire

4

2179

8716

... More
Oil seal/water seal/mechanical seal/rubber parts waterproof copper winding wire

9

151

1359

... More
Gun metal motor bearing bush

10

158

1580

... More
Gun metal thrust bearing Axle

8

282

2256

... More
Bearing housing upper

11

158

1738

... More
Bearing housing Lower

10

184

1840

... More
Revolving thrust Disc

7

199

1393

... More
M.S. motor base

6

290

1740

... More
Gun metal & sand guard

10

199

1990

... More
S.S. coupling & key set

5

358

1790

... More
Surcleap

6

158

948

... More
Nut-bolt, strut washer & packing materials etc. complete.

8

441

3528

... More
Stainless steel rotor sleeve

9

126

1134

... More
Rotor up to 2 HP

4

1826

7304

... More
Rotor up to 3 to 5 HP

5

2399

11995

... More
Repair of submersible pump parts 100 mm dia by opening and replacing defective part with compalible new part & assembly it with testing and reinstallation including etc. 23.20.1 PVC impellers

6

114

684

... More
PVC Bowl set

4

126

504

... More
PVC stage plate/impeller plate

6

109

654

... More
Stainless steel pump shaft

10

554

5540

... More
Gun metal bush

7

154

1078

... More
Stainless steel sleeve

6

111

666

... More
NRV suitable for pumpset

11

282

3102

... More
Suction housing

5

245

1225

... More
labour charges for repairing mono block/submersible motor including all machinery, T and P and labours etc. complete i.e. Rotor keyway repairs, machining, grinding, polishing, balancing, painting and other related works.

7

927

6489

... More
Installation & lifting out of pump set from tubewell/sumpwell and submersible pump. 23.22.1 Provision for lifting out unworkable submersible pump from tubewell from any depth with G.I./UPVC pipe shifting to work shop as per required suitable site.

6

2236

13416

... More
Provision for dismantling unworkable openwell pumps and shifting to work shop as per required suitable site.

5

1763

8815

... More
Provision for lifting out unworkable sump well pumps from any depth with and shifting to workshop as per required suitable site

8

1527

12216

... More
Provision for dismantling unworkable Mono block pumps and shifting to work shop as per required suitable site.

4

416

1664

... More
Provision for dismantling unworkable pressure pumps and shifting to workshop as per required suitable site.

5

1518

7590

... More
Repairing of control panel board with replacement of contactor kit set capacitors, boost up, condenser etc complete including wiring, fitting, and testing. 23.23.1 Single phasing preventer

11

715

7865

... More
Dry run protection

6

8092

48552

... More
Phase reversal protection device

7

4125

28875

... More
Replacement of overload relay unit set up to 15amp.

11

809

8899

... More
Replacement of overload relay unit set up to 15amp. Suitable with existing control panel board

9

961

8649

... More
Replacement of starter oil withfitting and testing the starter.

6

526

3156

... More
Replacement of Amp. Meter with fitting and testing complete.

4

328

1312

... More
Replacement of Volt meter with fitting & testing complete.

9

328

2952

... More
TPN MCB with box up to 32 amp. i/c fitting & testing complete.

5

1575

7875

... More
Rotary swich up to 32 amp. With fitting & testing complete.

8

592

4736

... More
Repair of monoblock pump upto 1.5 to 2.0 HP single/three phase including replacement of required parts and labour charges for taking out and installation including transportation etc

9

3700

33300

... More
Repair of monoblock pumps 3 to 5 HP 3 phase including replacement of required parts and labour charges for taking out and installation including transportation etc

7

5920

41440

... More
Providing of Core cut with suitable size as per specification at site.

6

4

29.43

... More
Supplying and fixing wall mounted storage/instantaneous type electric geyser, complete with inner copper container, heating element, thermostat, indicating lamp including inlet / outlet water pipe connection, electric connection testing and commissioning etc. as per specification. 24.26.8 15 Ltr. Capacity storage type geyser 5 star

4

6648

26592



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.