Public Works Department Tender
... More
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Opening Date7 Mar 2025
Closing Date28 Mar 2025
Tender Amount₹ 2,12,54,000
Costs
EMD
₹ 1,50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
165547Tender No
165547Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.cg.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Construction of embankment with Material Obtained from Borrow Pits/Borrow Area (Construction of embankment with approved material/selected soil having C.B.R.5 (unless specified otherwise in the contract) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
4042.19
223
901408
... More
Granular Sub-base as per Table:- 400-1
Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401
A Plant mix method (with Mechanically crushed stone only)
a For Lower Sub-base with
(i) Grading-III Material
1546.88
1423
2201210
... More
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98-2 011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts , joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings.
(i) Single row for one utility service
62.5
553
34563
... More
Providing and laying Reinforced Cement Concrete pipe NP 3 /prestressed concrete pipe. (Laying Reinforced cement concretepipe NP3 /prestressed concrete pipe for culverts including fixingcollar with cement mortar 1:2 but excluding bedding below ipes,excavation, protection works, ackfilling, concrete and masonry works in head walls and parapets . )
B 600 mm dia
50
2459
122950
... More
6.6 Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads)
(i) P.C.C. M-10
1031.25
2789
2876156
... More
(ii)P.C.C. M-15
902.34
3695
3334146
... More
6.7 Providing and laying un-reinforccd cement concrete without Dowel bars inoluding formwork and expansion, contraction & longitunal joints as per desing and as per IRC -62-2014,over a prepared base aper approved mix design and finishing to lines and grade as per Drawing for pavement thickness less than 200mm in low volume Roads
(i)PCC Grade M-30 with minimum Cement Content @375kg/cum
1031.25
4391
4528219
... More
Retro- reflectrorized Traffic signs (Providing and fixing of retro-reflectrorized cautionary, mandatory and ormatory sign as per IRC :67-2012 made of retro-reflective type ting vide clause 801.3,fixed over aluminum sheeting of quired thickness supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x 75 mm x 6mm firmly fixed to the ground by means of properly ed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60cm below ground level as per approved drawing and painting all components of the signs and supports as of IRC:67-2012) Amd 01.Dt. 12.10.15
C Made of Class -A High Intensity Super Engineering Grade Sheeting of Type II (for ODR &Village Road)
a) With Aluminum Sheeting of 2 mm thickness
(i) 900 mm equilateral triangle
6
3831
22986
... More
(ii) 800 mm x 600 mm rectangular
8
4507
36056
... More
b) With Aluminum Sheeting of 1.5 mm thickness
(i) 600 mm equilateral triangle
8
2506
20048
... More
(ii) 600 mm circular
8
3184
25472
... More
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorized sign as per IRC :67-2012 made of retro-reflective type sheeting and vide ause 801.3, fixed over aluminum sheeting, 2 mm thick with area exceeding 0.9 sqm and fixed on a mild steel frame of size 40 x 40 x 5 mm supported on 2 Nos. mild steel angle iron posts of size 75 mm x 75 mm x 6 firmly fixed to the ound with M 15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing) C Made of class - A High intensity Micro prismatic grade Sheeting of Type 1 (for ODR &Village Road)
5.76
8115
46742
... More
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc)
(i) 5th kilometer stone (precast)
2
2436
4872
... More
(ii) Ordinary Kilometer stone (Precast) (1+7)
1
1460
1460
... More
(iii) Hectometer stone (Precast)
6
410
2460
... More
Providing & Fixing Hazard Marker Type-2 Partial Retro Reflective Size 0.30 x 0.90M made of 16 gauge (1.6 mm) thick mild steel sheet Confirming to IS:2062 Painted with one cast of Zinc Chromate Stoving Primer and two coats of Black Stove Enamel (Oven Baked) paint with 10 cm bands of yellow Retro- Reflective Sheeting of Engineering Grade pasted a per IRC:79 including one MS angle Iron post of size 50x50x5 mm of 1.65 meter long duly painted with synthetic enameled paint block including bolts and fixing the same in M- 15 concrete black of size 30x30x30cm, including transportation etc. Complete.
16
1491
23856
... More
Providing and fixing guard stones 200 x 200 x 900 mm made of precast RCC M-20 grade fixed at 300 mm into the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400 mm and given two coats of paint with white and black bands including excavation.
200
431
86200
... More
Providing & Fixing tree studs in Square/ Round shape of 4” side/diameter made of 2 mm aluminum substrate ming to IS:736 -Material Designation, 24345 or 1900) end ective surface of High Intensity grade as specified in section 801.3 of MORT&H duly treated with HLVA and fixing the same th four Nos. high strength nails confirming to 1S:1367 on trees at site each.
145
67
9715
... More
Road Markers/Road Stud with Lens Reflector (Providing and fixing of road stud 100x 100 mm, die cast in uminum, resistant to corrosive effect of salt and grit, fitted with lens reflectors, installed in concrete or asphaltic surface by lling hole 30 mm upto a depth of 60 mm and bedded in a table bituminous grout or epoxy mortar, all as per BIS:873, part- IV:1973)
125
267
33375
... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35- 1997. The finished surface to be level, uniform and free from streaks and holes.)
110
707
77770
... More
Construction of RCC Drain/Cover/Chamber
(i)Construction of RCC Drain/Cover/ChamberExcavation for drain (Earth work in excavation for drain/chamber as per drawing and technical specification, including setting out,construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and
backfilling with approved material.)
1632
140
228480
... More
Construction of RCC drain/chamber cover, placing in position,providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
650.25
4146
2695937
... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as
per Drawing and Technical Specifications.
34.1
56301
1919864
... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications.
(i)PCC Grade M15
434.16
3768
1635915
... More
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete. Ordinary soil Up to 3 m depth
192.56
146
28114
... More
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes,excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . )
D1000 mm dia
40
5370
214800
... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200. (i) Granular material
38.56
905
34897
... More
Total
-
-
21253686
... More
Sub Divisinal Officer
-
-
-
... More
Public Works Department
-
-
-
... More
Lormi Sub Division, Lormi
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%