Public Works Department Tender

... More
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Public Works Department - PWD Tender

Opening Date7 Aug 2019
Closing Date16 Aug 2019
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.11 Open timbering in foundation trenches including strutting and shoring complete (measurements to be taken of the face area timbered.) 1.11.1 Depth not exceeding 1.5 M.

25.2

-

178

... More
3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.1.3 - 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).

124.39

-

2970

... More
3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.2.1- 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

109.25

-

4163

... More
3.2- Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.2.1- 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). 3.4 - Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

64.07

-

4260.5

... More
3.3 Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. 3.3.2- M-25 Grade ( Foundation)

61.31

-

4298

... More
3.3 Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. 3.3.2- M-25 Grade 3.4 - Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: GROUND FLOOR

88.27

-

4395.5

... More
3.3 Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. 3.3.2- M-25 Grade 3.4 - Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: FIRST FLOOR

79.08

-

4493

... More
3.3 Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. 3.3.2- M-25 Grade 3.4 - Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: SECOND FLOOR

64.05

-

4590.5

... More
3.3 Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. 3.3.2- M-25 Grade 3.4 - Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: THIRD FLOOR

8.59

-

4688

... More
3.12 -Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: 3.12.1- Thermo-Mechanically treated bars FE 415

49293.79

-

54.5

... More
3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.1.5 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

0.23

-

4073

... More
2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (Foundation and Ground Floor) 2.1.1 -Foundation,footing,base of column and plinth beam in any shape and size.

1302.99

-

139

... More
2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape

504.99

-

297

... More
2.1.8- Beams, lintels, cantilevers & walls

594.44

-

202

... More
2.1.13- Weather shade, chhajja, Cornices and mouldings

73.77

-

294

... More
2.1.7- Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) sqm 235.00

580.59

-

235

... More
2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings

26.81

-

230

... More
2.1.4 -Edge of slab, breaks in floor and walls upto 200mm

53.5

-

34

... More
2.1.3 Window sills, anchor blocks, string course, bends, copings, bed plates and like.

2.78

-

184

... More
2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: ( First floor ) 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape

161.16

-

297

... More
2.1.8- Beams, lintels, cantilevers & walls

396.5

-

202

... More
2.1.13- Weather shade, chhajja, Cornices and mouldings

59.47

-

294

... More
2.1.7- Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) sqm 235.00

273.6

-

235

... More
2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings

26.81

-

230

... More
2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.2 Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured)( Second floor ) 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape

132.01

-

297

... More
2.1.8- Beams, lintels, cantilevers & walls

378.7

-

202

... More
2.1.13- Weather shade, chhajja, Cornices and mouldings

53.17

-

294

... More
2.1.7- Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) sqm 235.00

193.19

-

235

... More
2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings

26.81

-

230

... More
2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.2 Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured) ( Third floor ) 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape

46.14

-

297

... More
2.1.8-- Beams, lintels, cantilevers & walls

15.4

-

202

... More
2.1.13- Weather shade, chhajja, Cornices and mouldings

0.95

-

294

... More
2.1.7- Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) sqm 235.00

14.4

-

235

... More
2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.2 Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured) ( Third floor ) 2.1.8-- Beams, lintels, cantilevers & walls lift 2

115.63

-

81

... More
lift 3

280.88

-

121.5

... More
lift 5

103.02

-

202.5

... More
lift 6

275.68

-

243

... More
lift 8

15.4

-

324

... More
2.1.13- Weather shade, chhajja, Cornices and mouldings lift 2

59.47

-

81

... More
lift 5

53.17

-

202.5

... More
lift 8

0.95

-

324

... More
2.1.7- Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) lift 3

273.6

-

121.5

... More
lift 6

193.19

-

243

... More
lift 8

14.4

-

324

... More
2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings lift 1

15.81

-

40.5

... More
lift 2

11.01

-

81

... More
lift 4

15.81

-

162

... More
lift 6

11.01

-

243

... More
1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.

489.24

-

65

... More
1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.

1145.2

-

371

... More
3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.

3.17

-

4237

... More
3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

63.39

-

93.5

... More
3.21 Providing and fixing in position impregnated fibre board confirming to IS: 1838 in expansion joints, including cost of primer, sealing compound all complete. 3.21.2 25mm thick

7.43

-

768

... More
4.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom, kitchen etc., by applying cement slurry mixed with water proofing cement compound consisting of following applications including surface preparation: i) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound@ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

44.52

-

182

... More
13.24 Providing and fixing one side polished 25 mm thick RAJIM SAND STONE shelves fixed in walls in cement mortar 1:3 (1 cement : 3 coarse sand) including finishing complete. 13.25 Both side polished

150.74

-

414

... More
7.4 Brick work with modular well burnt (open bhatta) clay ricks of crushing strength not less than 20 kg/sqcm and water absorption not more than 25% in foundation and plinth in: 7.4.1 Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) cum

19.48

-

3263

... More
7.4 Brick work with modular well burnt (open bhatta) clay bricks of crushing strength not less than 20 kg/sqcm and water absorption not more than 25% in foundation and plinth in: 7.4.1 Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) cum 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

125.46

-

3384

... More
7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 Cement Mortar 1:6 (1 Cement : 6 Coarse Sand)

31.81

-

3263

... More
7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: (Ground Floor)

80.49

-

3384

... More
7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:( First floor )

69.89

-

3505

... More
7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: (Second floor )

61.28

-

3626

... More
7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: (third floor )

5.59

-

3747

... More
7.10 Half brick thick brick masonry with modular well-burnt clay bricks of crushing strength not less than 25 kg/sqcm and water absorption not more than 20% upto plinth level: 7.10.2 Cement Mortar 1:4 (1 cement : 4 coarse sand) 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level

116.38

-

428

... More
7.11 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: 7.11.2 Cement Mortar 1:4 (1 cement : 4 coarse sand) 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: Ground floor

184.88

-

393

... More
7.11 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: 7.11.2 Cement Mortar 1:4 (1 cement : 4 coarse sand) 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: first floor

272.07

-

404

... More
7.11 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: 7.11.2 Cement Mortar 1:4 (1 cement : 4 coarse sand) 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: second floor

112.23

-

415

... More
7.20 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry.

670.94

-

62.5

... More
8.12 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 8.12.2 35 mm. thick (single leaf)

103.28

-

2005

... More
8.12 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 8.12.5 25 mm. thick (double leaf for cupboard shutters with piano type hinges

2.83

-

1669

... More
8.15 Extra for double leaf shutter instead of single leaf.

17.96

-

52

... More
8.94 Providing and fixing M.S. bright finished or black enameled Butt hinges IS: 1341 marked with necessary iron screws: 8.94.1 125x65x2.12mm

144

-

30

... More
8.99 Providing and fixing M.S. bright finished or black enameled sliding door bolts with bolts, nuts and necessary iron screws: 8.99.1 300x16mm

80

-

77.5

... More
8.100 Providing and fixing M.S. bright finished or black enameled door latch with necessary iron screws: 8.100.2 250x20x6mm

40

-

50.5

... More
8.102 Providing and fixing M.S. bright finished or black enameled Tower bolts (Barrel type) with necessary iron screws: 8.102.1 250 mm

40

-

34.5

... More
8.103 Providing and fixing M.S. bright finished or black enameled handles with necessary iron screws: 8.103.1 125 mm

96

-

51

... More
8.106 Providing and fixing MS bright finished single hanging door stopper with necessary MS steel screws complete.

48

-

12.5

... More
8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge.

84.15

-

346

... More
8.152 Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C'channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter). 8.152.2 Both side Pre-laminated panel PVC door shutter

26.78

-

2832

... More
9.13 Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

132

-

75

... More
9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.

2098.05

-

67.5

... More
8.1 Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. 8.1.2 Sal, bijasal, benteak, khair, haldu

3.55

-

61051

... More
8.126 Providing and fixing powder coated aluminium sliding door bolts with 16mm rod, necessary M.S. nuts bolts and screws etc complete. 8.126.2 250x16mm

22

-

150

... More
8.127 Providing and fixing powder coated aluminium door latch with 12mm rod,necessary M.S. nuts bolts and screws etc complete. 8.127.2 250x12mm each

18

-

54.5

... More
8.128 Providing and fixing powder coated aluminium tower bolts (Barrel type) with necessary M.S. screws etc complete. 8.128.2 200 x10mm

20

-

60

... More
8.129 Providing and fixing powder coated aluminium door handles 2.5mm thick with necessary M.S. screws etc complete. 8.129.1 150 mm

40

-

32

... More
8.130 Providing and fixing hanging powder coated aluminium door stopper with necessary M.S. screws etc complete. 8.130.2 Double

16

-

38.5

... More
8.148 Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge 8.148.2 Extruded section Profile size 42x50 mm. metre

9.9

-

196

... More
8.149 Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. 8.149.2 30 mm thick door shutters with styles and rails of size 60x30 mm

6.3

-

2488

... More
9.6 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. 9.6.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

2142

-

68

... More
9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. sqm

4.41

-

3330

... More
9.33 Providing and fixing GI wire gauge of average width of aperture 1.56mm with wire of 0.45mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete.

137.87

-

569

... More
9.37 Providing and fixing M.S. fan clamp/hook for ceiling fan made out of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop.

8

-

97

... More
9.39 Providing and fixing in position G.I. barbed wire (93.8gram/m) to concrete/ wooden/ angle iron posts (straight or diagonal) including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete(Cost of posts, struts to be paid for separately)

3000

-

9.4

... More
9.45 Providing and placing in position angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for required length and drilling holes upto 10 mm dia as per requirement including priming coat with red oxide zinc chromate primer and placing the post/ strut in cement concrete block.

1016.76

-

69.5

... More
9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grad AC-15. (Glazing to be paid for separately: 9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).

1096.94

-

338

... More
9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grad AC-15. (Glazing to be paid for separately: 9.47.1 For fixed portion

1002.44

-

331

... More
9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): 9.51.1 With float glass panes of 4 mm thickness

131.45

-

611

... More
9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): 9.51.2 With float glass panes of 5 mm thickness

30.09

-

708

... More
9.49 Extra for polyester powder coated (minimum 50 micron) aluminium sections instead of anodized.

1840.23

-

34.5

... More
9.36 Providing and fixing approved pipe hand rail to walls (ramps, stair cases) including cutting chases and repairing the same to original condition, applying a priming coat of red oxide zinc chromate primer. 9.36.1 M.S Pipe

60

-

71

... More
11.1 Providing and making 6mm thick cement plaster of mix: 11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)

1262.32

-

87

... More
11.1 Providing and making 6mm thick cement plaster of mix: 11.1.1 In Cement mortar 1:3 (1 cement : 3 fine sand

15.22

-

93

... More
11.2 Providing and making 12mm thick cement plaster of mix: 11.2.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)

3742.3

-

91.5

... More
11.2 Providing and making 12mm thick cement plaster of mix: 11.2.1 In cement Mortar 1:3 (1 cement : 3 fine sand

35.04

-

115

... More
11.3 Providing and making 15mm thick cement plaster on the rough side ofsingle or half brick wall of mix: 11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)

4421.52

-

107

... More
11.5 Neat Cement punning.

74.64

-

33

... More
11.9 Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer

8.64

-

43.5

... More
11.31 Providing and making 12mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: 11.31.2 Sunk Bands

300

-

2.6

... More
11.31 Providing and making 12mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: 11.31.3 Raised Band

300

-

3

... More
11.32 Providing and making 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: 11.32.2 Sunk Bands metre.

1540.54

-

3

... More
12.3 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 12.3.2 50 mm thick

15

-

254

... More
12.6 Cement plaster skirting upto 30 cm. height with cement mortar 1:3 (1cement : 3 fine sand) finished with a floating coat of neat cement including rounding of junction with floor. 12.6.1 18 mm thick in two layers of 12mm and 6mm

38.25

-

200

... More
12.7 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. 12.7.1 Size upto 200x300mm

333.08

-

587

... More
12.9 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. 12.9.1 Size 300x300mm

5.99

-

692

... More
12.9 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. 12.9.2 Size above 300x300mm

51.66

-

728

... More
12.37 Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tile including cleaning of joint etc complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 12.37.3 Dark shade using ordinary cement

6.06

-

518

... More
12.38 15mm thick Marble stone slab flooring over 18mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including grinding rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above 12.38.5 Udaipur green marble

2.93

-

1497

... More
12.39 15mm thick Marble stone slab in, tread & risers of steps, skirting, dado, walls and pillars on 12mm (average) thick base of cement mortar 1:4 (1cement : 4 coarse sand) and jointed with grey cement slurry including matching pigment, rubbing and polishing etc. complete. (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 M). 12.39.5 Udaipur green marble

3.09

-

1576

... More
12.50 KOTA stone slab 25mm thick in risers and treads of steps, skirting dado and pillar laid in 12mm (Average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single stone is to be used for riser and treads of steps and the width of stone for skirting and dado shall be equal to the height of skirting/ dado up to length of 1.0 M.)

64.28

-

990

... More
12.51 Extra for nosing in steps and treads of Kota stone slab.

94.5

-

69.5

... More
12.12 Providing and laying vitrified floor tiles with soluble salt printing, of size 600x600mm with water absorption less than 0.5% and conforming to IS : 15622 of approved make, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.

967.75

-

963

... More
14.9 Distempering with acrylic washable distemper to give an even shade. 14.9.1 On new work (Two or more coats)

6739.17

-

38

... More
14.15 Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with: 14.15.1 On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

3365.8

-

56

... More
14.22 Painting on new work (two or more coats) to give an even shade with: 14.22.2 Premium synthetic enamel paint

242.3

-

47

... More
18.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.1.3 White Orissa pattern W.C. pan of size 580x440 mm

9

-

2899

... More
18.4 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.4.1 White pedestal type

1

-

2882

... More
18.7 Providing and fixing 10 litre capacity P.V.C. low level flushing cistern conforming to IS : 7231, with all fittings and fixtures complete. 18.7.1 White

5

-

729

... More
18.17 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.17.3 White size 450x325 mm

6

-

1203

... More
18.17 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.17.2 White Size 550x400 mm

4

-

1408

... More
18.22 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 18.22.1 345x445 mm bowl depth 200 mm.

2

-

6298

... More
18.25 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 18.25.2 40 mm dia

7

-

88.5

... More
18.27 Providing and fixing cast iron grating for gully trap. 18.27.1 100x100mm square or round

20

-

30

... More
18.29 Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

6

-

599

... More
18.56 Providing and fixing sand cast iron S&S trap of self cleansing design with screwed down or hinged grating with or without vent arm as per IS: 1729 complete, including cost of cutting and making good the walls and floors : 18.56.1 100 mm inlet and 100 mm outlet

10

-

562

... More
18.56 Providing and fixing sand cast iron S&S trap of self cleansing design with screwed down or hinged grating with or without vent arm as per IS: 1729 complete, including cost of cutting and making good the walls and floors : 18.56.2 100 mm inlet and 75 mm outlet

10

-

497

... More
18.76 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.1 75 mm dia pipe.

395.6

-

182

... More
18.76 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.2 110 mm dia pipe.

140

-

267

... More
18.76 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.3 150 mm dia pipe

81.08

-

440

... More
18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.1 75 mm

60

-

113

... More
18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.2 110 mm

60

-

154

... More
18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.2 Double "Y" with or without door 18.77.2.1 75 mm

20

-

129

... More
18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.2 Double "Y" with or without door 18.77.2.2 110 mm

70

-

224

... More
18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.3 Vent covel 18.77.3.1 75 mm

10

-

34

... More
18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.3 Vent covel 18.77.3.2 110 mm

14

-

44

... More
18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.6 Nahani trap 110x75mm

16

-

90.5

... More
18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.7 Multi floor trap 110

6

-

122

... More
18.78 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.1 75 mm

50

-

57

... More
18.78 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.2 110 mm

50

-

61

... More
19.7 Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 19.7.1 15 mm dia. nominal bore

60

-

149

... More
19.7 Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 19.7.3 25 mm dia. nominal bore

95

-

258

... More
19.7 Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 19.7.4 32 mm dia. nominal bore

50

-

318

... More
19.8 Providing and fixing concealed in wall G.I. pipes medium class complete with G.I. fittings and clamps, including painting with anti corrosive bitumastic paint, cutting chases, making good the walls etc. and testing of joints complete: 19.8.1 15 mm dia nominal bore

108

-

188

... More
19.8 Providing and fixing concealed in wall G.I. pipes medium class complete with G.I. fittings and clamps, including painting with anti corrosive bitumastic paint, cutting chases, making good the walls etc. and testing of joints complete: 19.8.3 25 mm dia nominal bore

90

-

297

... More
19.9 Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete: 19.9.1 15 mm dia. nominal bore

45

-

131

... More
19.9 Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete 19.9.3 25 mm dia. nominal bore

40

-

222

... More
19.9 Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete 19.9.4 32 mm dia. nominal bore

50

-

272

... More
19.9 Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete 19.9.5 40 mm dia. nominal bore

100

-

308

... More
19.10 Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: (dia of main line to be measured) 19.10.1 25 mm nominal bore

43

-

200

... More
19.10 Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: (dia of main line to be measured) 19.10.2 32 mm nominal bore

20

-

224

... More
19.10 Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: (dia of main line to be measured) 19.10.3 40 mm nominal bore

18

-

278

... More
19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.1 Bib cock (400 grams)

36

-

382

... More
19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.6 Stop cock (concealed) (600 grams)

36

-

494

... More
19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.7 Angle valve for basin mixer and geyser points (450 grams

18

-

382

... More
19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.12 Bottle trap set with extension pipes

18

-

473

... More
19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.14 Soap dish plate

15

-

163

... More
19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.15 Shower rose (revolving type) (150mm)

11

-

269

... More
19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.16 Towel rail (600mm long x 20mm dia)

15

-

338

... More
19.15 Providing and fixing stainless steel drain jali of approved make/quality.

55

-

51

... More
19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 19.16.1 25 mm nominal bore

14

-

436

... More
19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 19.16.2 32 mm nominal bore

6

-

510

... More
19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 19.16.3 40 mm nominal bore

10

-

596

... More
19.18 Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 19.18.3 40 mm nominal bore

2

-

688

... More
19.11 Providing and fixing G.I. Union in G.I. pipe (New work) including cutting and threading the pipe and making long screws etc. complete: 19.11.1 15 mm nominal bore

18

-

85

... More
19.11 Providing and fixing G.I. Union in G.I. pipe (New work) including cutting and threading the pipe and making long screws etc. complete: 19.11.3 25 mm nominal bore

10

-

117

... More
19.11 Providing and fixing G.I. Union in G.I. pipe (New work) including cutting and threading the pipe and making long screws etc. complete: 19.11.4 32 mm nominal

5

-

148

... More
19.11 Providing and fixing G.I. Union in G.I. pipe (New work) including cutting and threading the pipe and making long screws etc. complete: 19.11.5 40 mm nominal bore

5

-

169

... More
19.43 Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same

8

-

125

... More
19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

13000

-

7.3

... More
19.48 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate

2

-

4644

... More
19.49 Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design

4

-

8013

... More
19.13 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: 19.13.2 Bib cock (350 grams

6

-

237

... More
19.13 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: 19.13.3 Stop cock (350 grams

8

-

237

... More
20.1 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 20.1.1 100 mm diameter

140

-

162

... More
20.1 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 20.1.2 150 mm diameter

100

-

262

... More
20.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 20.2.1 100 mm diameter S.W. pipe

140

-

357

... More
20.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 20.2.2 150 mm diameter S.W. pipe

100

-

436

... More
20.3 Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 20.3.2 150 x 100 mm size P type

6

-

1397

... More
20.7 Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 20.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)

2

-

6703

... More
20.11 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: 20.11.1 With 20x20 mm square bar each 168.00

5

-

168

... More
20.14 Supplying and fixing C.I. cover without frame for manholes : 20.14.1 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg.

1

-

1222

... More
20.27 Providing and constructing brick masonry road gully chamber 110x50x77.5 cm with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design.

12

-

5213

... More
20.31 Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

12

-

1709

... More
21.17 Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tube well within the selected habitation, including photography, nterpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable)

2

-

1502

... More
21.1 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level 21.1.1 All types of soil 21.1.1.4 200 mm dia

70

-

371

... More
21.1 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level 21.1.2 Rocky strata including Boulders. 21.1.2.4 200 mm dia.

20

-

457

... More
21.2 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. 21.2.2 Rocky strata including Boulders. 21.2.2.2 125 mm dia.

40

-

371

... More
21.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 21.3.3 150 mm nominal size dia.

80

-

540

... More
21.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) slotted pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in- charge. 21.4.3 150 mm nominal size dia.

10

-

546

... More
21.9 Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

0.18

-

1048

... More
21.10 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

6

-

654

... More
21.11 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 21.11.3 150 mm dia

1

-

217

... More
21.16 Providing ISI Mark 32 mm dia G.I. ( B class) riser pipe and M.S. plunger rod in 3 meter length socketed on one end as per IS: 1239 ( Part I) 1990 with up to date amendments and socket as per IS:2062/ 1990 up to date amendments.

50

-

275

... More
21.18 Providing and fixing filter of minimum 100 litre capacity for roof top rain water harvesting through tube well consisting of two layered HDPE tank with five layers (each layers of minimum 100 mm) consist of coarse sand, 4mm, 6mm, 8mm & 12 mm gravels with stainless steel wire mesh fixed between each layer with suitable length and sufficient numbers of 110 mm dia PVC pipe pieces in the bottom of tank to support the above layer including fixing of inlet and out let P.V.C. pipe of required diameter upto 2 metre length on each side, Cement Concrete plateform of required size complete as directed by Engineer in charge. (excluding cost of tubewell and inlet and outlet pipe beyond 2 metre)

1

-

18.5

... More
21.19 Providing and fixing 80-100 mm dia PVC ball valve for inlet/ outlet of rain water harvesting pipe and filter.

2

-

644

... More
14.13 Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even.

5090.31

-

94.5

... More
4.13 Grading roof for water proofing treatment with: 4.13.2 Cement mortar 1:3 (1 cement : 3 coarse sand)

32.22

-

4612

... More
3.12 Construction of embankment with Material Obtained from Borrow Pits/Borrow Area (Construction of embankment with approved material/ selected soil having C.B.R.5 (unless specified otherwise in the contract) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)

658.75

-

223

... More
4.1 Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 B By Mix in place method Disintegrated rock i.e moorum having CBR value not less than 20 and P.I. and L.L. not more than 6 and 20 respectively. (For Village roads only)

222.5

-

460

... More
6.6 ROAD Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads and ODR ) (iii) P.C.C. M-25

75

-

4286

... More
6.1 ROAD Dry Lean Cement Concrete Sub-base as per IRC:SP-49 (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)

37.5

-

2332

... More
4.13 Construction of Shoulders (Construction of shoulders as per clause 408 with selected soil from borrow pits / borrow areas having CBR not less than 12 and shall have L.L. and P.I. not more than 25% and 6% respectively, inclusive of all leads and lifts, including clearing and scrapping of existing surface, providing required cross fall, compacting. watering rolling and royalty charges etc. complete. A With vibratory roller

45

-

291

... More
3.20 Construction of RCC open drain (ii) Construction of RCC open drain 0.60m x 0.60m inside dimension lined with 120 mm thick RCC M-20 walls, 120 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 8 mm dia horizontal bars @ 150 mm c/c and L-shaped 8 mm dia vertical bars @ 150 mm c/c (L= 800 mm) including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications.

57

-

2592

... More
3.25 Construction of RCC Drain/Cover/Chamber (ii) Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement.with RCC M-20

4.4

-

4146

... More
3.25 Construction of RCC Drain/Cover/Chamber (iii) Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.

0.35

-

56301

... More
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in concealed PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required. Short Point

80

-

278

... More
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in concealed PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required. Medium Point

108

-

431

... More
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in concealed PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required. Long Point

174

-

595

... More
Wiring for twin control light point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in concealed PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required.

2

-

417

... More
Extra for providing and fixing light plug point on board in concealed PVC conduit point wiring with modular type 3 pin 5 amp socket outlet and 5 amp switch including cost of base and cover plate and G. I. box etc. as required.

75

-

240

... More
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Medium Point

5

-

701

... More
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Long Point

7

-

988

... More
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Extra Long Point I

7

-

1385

... More
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Extra Long Point II

10

-

1788

... More
Wiring for power plug point with 2x4 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Long Point

4

-

1347

... More
Wiring for power plug point with 2x4 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Extra Long Point I

7

-

1838

... More
Wiring for power plug point with 2x4 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Extra Long Point II

7

-

2383

... More
Wiring for power plug point with 2x4 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Extra Long Point III

2

-

2915

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed PVC conduit as required. 3 X 2.5 sq. mm in 20mm conduit

439

-

104

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed PVC conduit as required. 6 X 2.5 sq. mm in 25mm conduit

230

-

172

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed PVC conduit as required. 9 X 2.5 sq. mm in 32mm conduit

153

-

249

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed PVC conduit as required. 12 X 2.5 sq. mm in 32mm conduit

113

-

306

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed PVC conduit as required. 3 X 6 sq. mm in 25mm conduit

32

-

183

... More
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ concealed, steel/ PVC conduit/ PVC casing caping as required. 2 x 1.5 sq. mm

115

-

33

... More
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ concealed, steel/ PVC conduit/ PVC casing caping as required. 3 x 2.5 sq. mm

50

-

64.5

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Fan regulator (two module size) electronic stepped type moving all rounds

76

-

203

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as required. T.V. antenna socket outlet

2

-

74.5

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Batten/ angle holder

152

-

41

... More
Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as required.

1

-

879

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as required. Deluxe

2

-

180

... More
Providing and fixing following size FR PVC insulated, PVC sheathed, flexible copper conductor cable on the floor/ wall, or side of the table/ door etc. as required. 1.0 sq. mm two core

415

-

25.5

... More
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as required.

76

-

42.5

... More
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, earthing etc. complete as required. 1200 mm sweep

76

-

1503

... More
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 1.6mm to ceiling fan including painting with matching colour etc. as required. 45 cm long

20

-

27

... More
Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as required. (If provided at the time of installation of ceiling fan)

76

-

45.5

... More
Supplying and fixing of wall/ cabin fan of 400mm sweep including connection etc. as required.

1

-

2282

... More
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as required. 300 mm sweep

15

-

2558

... More
Supplying, installation, testing and commissioning of following surface/ concealed type fluorescent fitting (luminaries) complete with electronic ballast/ copper ballast glow type starter but without fluorescent lamp, on ceiling/ wall surface, earthing the fitting etc. as required. 4' x 40 W single box type

102

-

724

... More
Supplying, fixing, testing and commissioning of following 230/250 volts fluorescent lamp (tube) in existing lighting luminaries as required. 4' x 36/40 watt

102

-

51

... More
Supplying, fixing, testing and commissioning of following CFL (Built in choke type) in existing lighting luminaries as required. 85 Watt

2

-

907

... More
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 5 Watt

24

-

648

... More
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 9 Watt

128

-

973

... More
Supplying, installation, testing and commissioning of following 230/250 volts CFL street light fitting with perplex cover on pole bracket complete but without lamp as required. 85 watt

2

-

1407

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 5 KV surge protection on pole bracket complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 60 watt

16

-

10115

... More
Providing and fixing wooden board of suitable size for energy meter etc complete as required.

2

-

117

... More
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as required. (Thimbeling shall be paid separately).200 amps

3

-

524

... More
Providing and making interconnection in cubical panel between BBC and switchgears with following size aluminium strip of length upto 50cm as required (To be measured separately for each phase/ neutral). 20x5mm (100 amps)

4

-

74.5

... More
Providing and making interconnection in cubical panel between BBC and switchgears with following size PVC insulated copper conductor cable lead of length upto 50cm including providing copper thimbles on both ends as required (To be measured separately for each phase/ neutral). 10 sqmm (32 amp)

24

-

73

... More
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as required. (Only face area is to be measured) Upto 300 mm deep

2.25

-

6492

... More
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as required. 200 amp (30x5mm)

1.5

-

858

... More
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA

6

-

2514

... More
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 25KA

1

-

10179

... More
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door

1

-

986

... More
Supplying and fixing on surface/ recess vertical type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, with 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland/ knock out plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door

5

-

4314

... More
Supplying and fixing on surface/ recess vertical type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, with 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland/ knock out plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door

1

-

5391

... More
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps

90

-

154

... More
Supplying and fixing TP MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

5

-

1048

... More
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps

1

-

234

... More
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

1

-

593

... More
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as required.

6

-

89

... More
Providing and fixing penal mounting following rating digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as required. 0-500 amps

1

-

902

... More
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as required. Digital type

1

-

902

... More
Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as required Analoge type

1

-

2715

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.

5

-

3454

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as required.

4

-

6754

... More
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required.

60

-

76

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as required.

55

-

38

... More
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as required. 75 mm outer dia

225

-

202

... More
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as required. 90 mm outer dia

120

-

231

... More
Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as required. 50 mm internal dia

80

-

367

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 2 x 6 sq. mm

55

-

240

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 3.5 x 35 sq. mm.

45

-

347

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 4 x 10 sq. mm.

290

-

278

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 4 x 16 sq. mm.

35

-

291

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as required. 3.5 x 35 sq. mm.

35

-

187

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as required. 4 x 10 sq. mm.

210

-

117

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as required. 4 x 16 sq. mm.

25

-

130

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as required. 3.5 x 35 sq. mm.

10

-

209

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as required. 4 x 10 sq. mm.

65

-

140

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as required. 4 x 16 sq. mm.

6

-

153

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as required. 3½ X 35 sq. mm (28 mm)

4

-

168

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as required. 4 X 10 sq. mm (22 mm)

40

-

108

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as required. 4 X 16 sq. mm (22 mm)

8

-

110

... More
Supply of swaged steel tubular pole as per IS 2713 with base plate of size 300x300x6mm welded at bottom, necessary hole for cable entry and earthing stud welded at specified height including painting with one coat of red oxide zinc chromate primer. Designation 410 SP-8 height 7.50 metre

5

-

8417

... More
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as required. Single Over Hang 0.75 metre Long

5

-

949

... More
Erection of STEEL TUBULAR or "H" BEAM/ ISMB pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation and cement concrete collar of size 0.4 metre dia and 0.50 metre height from ground level including excavation and refilling etc. as required of length: 7 metre to 10 metre

5

-

2513

... More
Supplying and fixing water tight terminal box made of 1.6mm thick M.S. sheet with detachable gland plate in bottom, hinged front open able cover, rubber gasket, having 1 Nos 4way connector and 1 No SPMCB inside the box for cable connection, fixed to pole with 2 Nos clamp made from 40x3mm M.S. flat with 2 No nut bolt dully painted with 2 coat of red oxide paint and 2 coat aluminium paint complete as required. 20x15x15 cms.

5

-

653

... More
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as required.

18

-

163



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.