NMDC Limited Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

NMDC Limited - NMDC Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Aug 2024
Closing Date6 Sep 2024
Tender Amount₹ 16,12,466 
Notes
Download

Costs

Summary

Biom/bc/contracts/ote(89) /2024-25/elec/e-037

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for Cicuit with PVC insulated multistrand (approved make) 3 x 6 sqmm copper wires for Phase/Neutral & Earthing in PVC channel Casing Caping system of suitable size or concealed in the wall/panel through pipe. The work includes all the required materials and terminations at both ends.

200

-

-

... More
Point Wiring for 5/6 ampere same board power point with supplying and fixing suitable size box with modular plate & cover in front on surface including providing and fixing 3 pin 5/6 amps modular socket outlet`and 5/6 modular switch, connection etc as required Complete in all respect.

21

-

-

... More
Point Wiring for 5/6 ampere saparate board power point with supplying and fixing suitable size box with modular plate & cover in front on surface including providing and fixing 3 pin 5/6 amps modular socket outletand 5/6 modular switch Complete in all respect. Rates are equal for short, medium and long points.

14

-

-

... More
Supplying & Fixing 15/16 Amp. Modular switch and 6 Pin 15/16 Amp Socket Outlet along with 1 or 2 Module PVC Box, Modular base & Cover plate, Complete in all respect

48

-

-

... More
Supply and fixing on surface/recess SPN (2+12) way Double Door DB,415 V,SPN MCB distribution board with tinned copper bus bar,common neutral link,earth bar,din bar,detachable gland,including interconnection,earthing etc. as required, with following arrangements, 1.RCCB Having Sensitivity 30 mA,2 pole, 40 Amps Incomer ---1 nos. 2.Single pole MCB, 32 Amp, "C" series as outgoing---4 nos. 3.Single pole MCB, 20 Amp, "C" series as outgoing---4 nos. 4.Single pole MCB, 10 Amp, "C" series as outgoing---4 nos. With Neutral/Earthing distribution links. The DB has to be fitted on the required size of fabrIcated frame & grouted or partially/completely consealed on the wall as per the site condition. Complete in all respect and as per the approved make.

5

-

-

... More
Supply and fixing of Vertical TPN 8 way (8nos.TP or 24 nos.SP outgoing)Double Door DB, IP43/42 with following arrangements, 1. 200Amps MCCB,3pole,25k Amps Br.Capacity, as incomer.-1 no. 2. MCB ,3 pole, 32Amps , as outgoing ---6nos. 3. MCB ,1 pole,25Amps , as outgoing ---4nos. 4. MCB ,1 pole,10 Amps , as outgoing ---2 nos With Neutral/Earthing distribution links.The DB has to be fixed on the wall, as per the site condition. Complete in all respect.All the MCBs Shall be of "C" Characteristic and Breaking Capacity should be 10KA.

1

-

-

... More
Supply and Fixing of 125Amp, 36kA, 4 Pole MCCB with thermomagnetic release and terminal spreaders in exixting cubicle panel board including drilling holes in cublicle panel, making connections as required..

1

-

-

... More
Supplying and fixing 20 Amps, 240 Volts,SPN industrial type,socket outlet,with 2 pole and earth,metal enclosed plug top alongwith 20 amps "c"curve SP, MCB in sheet enclosure on surface or nin recess,with chained metal cover for the socket outlet and compete with connections,testing and commissioning etc as required

20

-

-

... More
Supply of Double ball bearing,Ceiling fan(1200mm), as per the approved make. Complete with down rod, canopy, hanging shackle, blades etc. Make:USHA/CG/Khaitan/Anchor.

4

-

-

... More
Supplying & fixing stepped type electronic fan regulator on existing modular plate switch box including connection as required.As per the approved ma

4

-

-

... More
Supply and Fixing of 12 to 16mm Ceiling fan Hook/Anchor Fastener on ceiling, Slabs, Cross Channels/Pipes. This includes all the required materials to complete the work. Drilling shall be done with proper Drill Machine only, no hammering will be allowed.

4

-

-

... More
Supply & Fixing of 4 Feet LED Tube Light with diffuser, reflector, driver complete in al respect. Minimum Watage 20 Watt, Minimum lumens-2000, 6500K. Make: Philips/GE/CG/ Havells/Halonix/wipro

50

-

-

... More
Supply,fixing & testing of Heavy duty (continous running) Exhaust fan as per the approved make, 380mm sweep. This is to be fixed on the wall in available slot and complete in all respect .

12

-

-

... More
Earthing with 2.5 mtrs. long earth electrode made of 40mm dia. Class "B" GI Pipe having staggered holes of 10 mm dia. at 150mm interval, burried inside the ground to obtain proper earth resistance with funnel, mesh, necessary GI nuts/bolts, washers, terminals, clamp etc.The work includes all the required materials & digging of suitable pit and filling with salts, charcoal and sand in layers, all around the electrode, as per the standard practice. After settling of the soil, making 100 mm thick Solid block masonry chamber of size of 600x600 (outer to outer) x 300 mm height in cement mortar 1:6, plastered with cement mortar 1:4, 12 mm thick at out side and the chamber shall be covered with a RCC (1:2:4) slab of size of 600mm x 600mm of 50mm thick to fit on the chamber at the top.

4

-

-

... More
Supply and fixing of 25mm x 5mm GI strip for connecting the Main DBs to the earth station. The work includes welding/clamping of strips, concealling into the wall, terminating to the DBs etc. as per the site condition. The strip should be bent properly and dressed according to the site condition.

200

-

-

... More
Undergrounding of XLPE/PVC insulated, Armoured, sheathed, 1.1 KV grade of size upto 4x 185 Sqmm. Power Cable/upto 100 Pair Telecom Cable direct in ground including excavation, sand cushioning, protective covering with bricks on both the sides & Top, refilling the trench, masonry works required for crossing Nallah/Walls, termination of all the ends with cable glands etc.The work includes all the neccesarry materials except the Cables.

400

-

-

... More
Laying of XLPE/PVC insulated, armoured, sheathed, Al., Power cable upto the size of 4x185 Sqmm and Telecom Cables along the wall with saddles/clamps, through pipe, in trench, along the pole etc. of required size & termination at both the ends.The work includes termination of all the ends with cable glands and all the neccesarry materials except the Cables.

400

-

-

... More
Supply of Pedestrial Fan( Iron Body Completely), Fan Size 600 millimeter, Oscillating, Air Delivery 150 Cu Metre/Min for 600 mm, Rated voltage 240V AC. Make: Usha/Piolt/Crompton/ Coral/Any Standard make

10

-

-

... More
Supply of Heavy Duty Industrial Air Circulator Wall Mount Fan( Iron Body Completely), Fan Size 600 millimeter, Oscillating, Air Delivery 150 Cu Metre/Min for 600 mm (min.), Rated voltage 240V AC. Make: Usha/Almonard/Crompton/Havells /AnyStandard make

10

-

-

... More
Supply and fixing of 200 Watt LED High Bay Fitting 230V AC, 50Hz, IP66, Heat Resistant, Toghnend Glass, Complete with all accessories. Driver shall have Overcurrent/Oveload and Surge protection. White LED conforming to LM 80 and Lumen Output to LM 79. Fitting arrangement on the Pole should be minimum 2.5 Metres inches Dia, complete in all respect. MAKE: Philips/ Surya/CG/Syska/Havells/Haloniox/Wipro/Orient/ GE/ Bajaj.

20

-

-

... More
Supply and fixing of 120 Watt LED Street Light Fitting 230V AC, 50Hz, IP66, Heat Resistant, Toghnend Glass, Complete with all accessories. Driver shall have Overcurrent/Oveload and Surge protection. White LED conforming to LM 80 and Lumen Output to LM 79. Fitting arrangement on the Pole should be minimum 2.5 Metres inches Dia, complete in all respect. MAKE:Philips/Surya/CG/Havells/Haloniox/Wipro/Orient /GE /Bajaj.

10

-

-

-

-

-

... More
Prices must be filled in the exact same format as given above. Any variation in format, description, unit, quantity or T&C, if noticed, may lead to rejection of the bid.

-

-

-

... More
In case some or many of the items of BOQ are left blank, the offer and subsequent evaluation shall be treated as per the manner specified in Corporation's manuals.

-

-

-

... More
In case of discrepancy between rates and amount quoted above, the quoted rates shall prevail and appropriate corrections shall be made by corporation during evaluation.

-

-

-

... More
Adjustments made by the Corporation as a part of Correction of Errors in the quoted BOQ, shall be final and binding upon the bidders. If a bidder does not except the corrected calculation, their bid shall be rejected.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.