Nava Raipur Atal Nagar Vikas Pradhikaran Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Nava Raipur Atal Nagar Vikas Pradhikaran Tender

Solid Waste Management
Opening Date23 Feb 2022
Closing Date25 Mar 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

1706.71

-

-

... More
Filling from available excavated stuff (Excluding rock) in trenches, plinth,sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.

11419

-

-

... More
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.

8046

-

-

... More
Supplying chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified.

30350

-

-

... More
Diluting chemical emulsion (Chlorpyriphos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm.

10761

-

-

... More
Diluting chemical emulsion (Chlorpyriphos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the intervals of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).

12494

-

-

... More
Diluting chemical emulsion (Chlorpyriphos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the intervals of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).

5509

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Foundations, footings, base of columns and plinth beam in any shape and size.

10400

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Wall of any thickness including attached pilasters, buttresses etc. in super structure.

170

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Columns, Pillars, Piers and likes- rectangular or square in shape

7161

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)

12878

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Beams, lintels, cantilevers & walls

11952

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Vertical and horizontal fins individually or forming box, louvers bands, almirah shelves and likes.

3080

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Weather shade, chhajja, Cornices and mouldings

2468

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Spiral / folded plate type stair cases including risers and landings

170

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Stair cases of all types excluding spiral and folded plate type, including risers and landings

1164

-

-

... More
DPC: Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including formwork.

93

-

-

... More
Water proofing material: Providing and mixing water proofing material in PCC/ RCC work in the proportion recommended by the manufacturer.

43813

-

-

... More
Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

734

-

-

... More
Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with sand including finishing the top smooth.

1760

-

-

... More
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluidng cost of form work PCC. 1 cement:3 coarse aggregate:6 graded stone aggregate.

2354

-

-

... More
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluidng cost of form work PCC. 1 cement:2 coarse aggregate:4 graded stone aggregate

17

-

-

... More
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. M-20 Grade

107

-

-

... More
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. M-25 Grade

7084.85

-

-

... More
Providing and laying design mix M30 grade (self compacting) reinforced cement concrete with crushed graded stone aggregate 20mm nominal size having self compacting admixture, water proofing material, using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work and steel all complete as per direction of EIC. M-30 Grade.

124

-

-

... More
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. M-35 grade

101

-

-

... More
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

3995

-

-

... More
Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement : 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement : 3 coarse sand) but excluding reinforcement.

238

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

595501.6

-

-

... More
Providing and laying integral cement based water proofing treatment on roofs, balconies, terraces etc with average thickness of 120mm and minimum thickness at khurra as 65 mm, consisting of following operations including surface preparation: i) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement mixed with water proofing compound conforming to IS. 2645 over the RCC slab including adjoining walls upto 300mm height. ii) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) mixed with water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) mixed with water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. iii) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645. iv) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) mixed with water proofing compound conforming to IS : 2645 including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. v) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.

10490

-

-

... More
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:3 (1 cement : 3 coarse sand)

36

-

-

... More
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:4 (1 cement : 4 coarse sand)

5270

-

-

... More
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand)

799

-

-

... More
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

3480

-

-

... More
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 40 in superstructure above plinth level upto plinth level: Cement Mortar 1:3 (1 cement : 3 coarse sand)

776

-

-

... More
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level:

776

-

-

... More
Providing and fixing antique/ SS finished brass butt hinges with antique/SS polished MS screw complete: 125x85x5.50 mm (Heavy Type)

2044

-

-

... More
Providing and fixing antique/ SS finished brass parliamentary hinges with antique/ SS polished MS screw complete: 150x125x27x5mm

2024

-

-

... More
Providing and fixing antique/ SS finished brass sliding door bolt with necessary bolts, nuts and antique/ SS polished MS screw complete: 300x16 mm

506

-

-

... More
Providing and fixing antique/ SS finished brass door latch with antique/ SS polished MS screw complete: 300x16x5mm

506

-

-

... More
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete 150mm

507

-

-

... More
Providing and fixing stainless steel hanging door stopper with necessarystainless steel screws complete. Double

508

-

-

... More
Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge. Extruded section Profile size 48x40 mm.

817

-

-

... More
Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture . M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter). Both side Pre-laminated panel PVC door shutter

263

-

-

... More
Providing and fixing flush door shutters, conforming to IS : 2202(Part-I),decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 35 mm. thick

1228

-

-

... More
Providing and fixing stainless steel wire mesh of average width of aperture 1.56mm with wire of dia 0.45mm to doors, windows and clerestory windows including 19x12mm teak wood beading etc. complete.

170

-

-

... More
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting,hoisting, fixing in position upto a height of 5m above plinth level,consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. Electric resistance or induction butt welded tubes Grade-250, 50kg/sqm

90325

-

-

... More
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. ; Electric resistance or induction butt welded tubes Grade-300

100

-

-

... More
Extra for hoisting trusses and placing in position over height above 5m for every 2.5 m height or part there of.

90325

-

-

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

817

-

-

... More
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. SS Grade 304

4412

-

-

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.

52797

-

-

... More
Providing and fixing steel door made of angle iron of suitable sizes with M.S. grill of approved pattern made of M.S. flats or square or round bars coat of red oxide zinc chromate primer.

170

-

-

... More
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

170

-

-

... More
Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with boltsand nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate primer. Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet.

2290

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately) For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including cost of PVC/neoprene gasket required (Fittings shall be paid for separately).

14949

-

-

... More
Providing Fixing 5 mm thick transparent white acrylic plastic sheets of approved quality in window with fastners, rubber, gripper stiffners complete.

1850

-

-

... More
Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick sheet (weight 8.60 kg/m2) .

2785

-

-

... More
Providing and fixing 97mm thick Gypsum board partition upto ceiling height consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120, consisting of floor and ceiling channel 50mm wide having equal flanges of 32mm and 0.55mm thick fixed to the floor and ceiling at the spacing of 610mm centre to centre with dash fastener of 12.5mm diameter 40mm length and the studs 48mm wide having one flange of 34mm and other flange 36mm and 0.55mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610mm centre to centre by 6mm dia bolts and nuts at both ends of partition fixed flush to wall with rawl plugs at spacing of 450mm centre to centre and fixing of boards to either side of frame work by 25mm dry wall screws on studs, floor and ceiling channels at the spacing of 300mm centre to center and 97mm thick Gypsum board which includes one layer of tapered edge 12.5mm thick Gypsum plaster board (conforming I.S. 2095-1982) screw fixed with 25mm screws at 300mm centre to centre to either side, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, joint finisher and two coats of primer suitable for board as per manufacture'sspecification and Direction of Engineer-in-charge all complete.

2765

-

-

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In cement Mortar 1:3 (1 cement : 3 fine sand)

800

-

-

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:4 (1 cement : 4 fine sand)

21487

-

-

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

4825

-

-

... More
Providing and making 12mm thick cement plaster of mix: In cement Mortar 1:3 (1 cement : 3 fine sand)

272

-

-

... More
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:4 (1 cement : 4 fine sand)

21200

-

-

... More
Providing and making 6mm thick cement plaster of mix: In Cement Mortar 1:4 (1 cement : 4 fine sand)

15500

-

-

... More
Providing and making 6mm thick cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and a thick coat of lime wash on top of wall when dry for bearing of R.C.C. slab and beam.

93

-

-

... More
Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer.(Powder)

1410

-

-

... More
Extra for providing and mixing water proofing Chemical in cement plaster work in proportion as recommended by manufacturer. (Liquid)

174

-

-

... More
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size above 200x300mm

13702

-

-

... More
Providing,laying and Fixing 10 to 12mm thick Antiskid external flooring tiles of approved size 600x600mm and above conforming to IS specification of approved make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete with proper adhesive to paste on the surface, as per direction of Engineer Incharge.

14181

-

-

... More
Chequered terrazzo tiles 22 mm thick with graded marble chips of size upto 6mm in floors on 25mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles including grinding rubbing and polishing complete. Medium shade using approximately. 50% white cement and 50% ordinary cement.

170

-

-

... More
15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above). Granite stone grey/pink

85

-

-

... More
15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above). Granite stone black

85

-

-

... More
15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m).

210

-

-

... More
25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm)

2163

-

-

... More
KOTA stone slab 25mm thick in risers and treads of steps, skirting dado and pillar laid in 12mm (Average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single stone is to be used for riser and treads of steps and the width of stone for skirting and dado shall be equal to the height of skirting/ dado up to length of 1.0 M.)

1632

-

-

... More
Extra for nosing in steps and treads of Kota stone slab.

768

-

-

... More
Providing and fixing 15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. Granite stone black

1071

-

-

... More
Providing and fixing 15mm thick Granite (machine cut, table rubbed & mirror polished on both sides) for partition curtain in toilets or similar locations of required size in wall with cement mortar 1:4 (1 cement : 4 coarse sand) including cutting chase in wall and joint with wall treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. Granite stone grey/pink

67

-

-

... More
Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete Upto 2 mm thickness to make surface even and smooth in line and level.

19716

-

-

... More
Providing and applying plaster of paris putty over plastered ceiling surface including scaffolding complete Upto 2 mm thickness to make surface even and smooth in line and level.

15500

-

-

... More
White washing with whiting to give an even shade. On new work (Three or more coats)

1700

-

-

... More
Distempering with acrylic washable distemper to give an even shade On new work (Three or more coats)

36970

-

-

... More
Providing and applying 2mm thick ready mix exterior grade approved make putty on walls to make the surface smooth and even.

18715

-

-

... More
Finishing walls with water proofing cement paint of required shade to give an even shade. On new work (Two or more coats applied @ 3.84 kg/10 sqm)

1700

-

-

... More
Painting exterior surface with PREMIUM ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc.complete with: On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm

18017

-

-

... More
Painting exterior surface with PREMIUM ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc.complete with: On old work (One or more coats applied @ 0.83 ltr/ 10 sqm)

9263

-

-

... More
Painting exterior surface with TEXTURED exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with: On new work (Two or more coats applied @ 3.28 ltr/10 sqm

10013

-

-

... More
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint (top most approved branded quality)

2000

-

-

... More
Finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including priming coat with epoxy primer, preparation of surface, etc. complete.

1090

-

-

... More
Painting on new work (two or more coats) to give an even shade with: Premium synthetic enamel paint

9861

-

-

... More
Supplying, filling, spreading & leveling stone boulders/ Gravels/ Coarse sand, in recharge pit, in the required layers and thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (excavation of pit will be paid separately). Gravels of size range 5 mm to 10 mm, over the existing layer of boulders.

78

-

-

... More
Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material within 50 metre lead.

2091

-

-

... More
Demolishing brick masonry including arches, stacking of serviceable material disposal of unserviceable material within 50 metres lead. In cement mortar.

2845

-

-

... More
Demolishing cement concrete including disposal of material within 50 metre lead. 1:4:8 or leaner mix

2140

-

-

... More
Demolishing stone rubble masonry including arches, stacking of serviceable material and disposal of unserviceable material within 50 Metres lead as per direction by Engineer-in- Charge. In cement mortar

193

-

-

... More
Demolishing cement concrete including disposal of material within 50 metre lead. 1:3:6 or richer mix

188

-

-

... More
Dismantling steel work in single section in RS Joists, channels, angles, flats, I-section and T-section including dismembering and stacking within 50 Metres lead.

821.2

-

-

... More
Carriage by mechanical transport upto 5 km lead: Dismantled Building debris (Mulba)

6451

-

-

... More
Extra for mechanical transport for every one km or part thereof beyond first 5 km lead. Dismantled Building debris (Mulba)

5931

-

-

... More
Dismantling lime/ cement plaster or skirting at any height raking out joints and cleaning the surface for plaster including disposal of rubbish within 50 metres lead.

14647

-

-

... More
Dismantling doors chowkhats with shutters (steel or wood) including architrave, hold fast etc. complete and stacking within 50 metres lead.

176

-

-

... More
Dismantling windows chowkhats with shutters (steel or wood) including architrave, hold fast etc. complete and stacking within 50 metres lead..

567

-

-

... More
Repairs to plaster in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls with cement mortar 1:4 (1 cement : 4 fine sand) complete including disposal of rubbish to the dumping ground within 50metres lead : Thickness upto 15mm

11756

-

-

... More
Painting on old work (one or more coats) to give an even shade with: Satin synthetic enamel paint

547

-

-

... More
Excavation in Soil (by Mechanical Means.);Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300.

3218

-

-

... More
Compacting Original Ground supporting sub-grade Loosening of the ground upto a level of 500 mm below the subgrade level , watered, graded and compacted in layers to meet requirement of table 300-2 for sub grade construction

3218

-

-

... More
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401; Grading-III Material, 150mm thick .

1145

-

-

... More
Providing and fixing factory made confirm to all technical specification of Bureau of Indian standards 15658 of 2006 for heavy duty pavers resulting in consistent and uniform quality , rubber molded, white cement based, pigmented block lacquer coating & cured through drying process mechanically vibrated and compacted pre cast interlocking premium pavers blocks in M40 grade, 60mm thickness of approved size, design and colour with providing and laying in position over cement mortar(1:3) of 25mm avg. thhickness.

9327

-

-

... More
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in PCC M20 grade on PCC M10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409)

3168

-

-

... More
Two coats on new surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)

1215

-

-

... More
Providing and fixing exterior grade of 30mm thickness Wood Plastic Composite WPC. grill of approved pattern on frame of windows or openings etc. with all necessary fitting complete.

34

-

-

... More
Providing & Installation of Weld Mesh Fencing System including Posts as per design and specification given below all complete as per direction by Engineer-in-Charge. Panel Width = 2500mm, Panel Height = 1560 mm, Panel Wire Dia = 5 mm in Pre-Galvanised up to min. 70 GSM, Tolerances are in accordance with EN 10218-2. Tensile Strength of Vertical & Horizontal wires: Minimum 400N/mm2, Panel Mesh Size = 200 mm x 50 mm , Panel V Bends = 03 Nos., Panel Finish = Dual PPC Powder Coated up to min. 140 Microns in RAL 6005 (GREEN) or as approved, Post Type = H Profiled, 70 mm x 40 mm x 2 mm Thick. Post Height = 1600 mm. Post Mounted on Pre-welded Universal Base Plate of Size = 175 mm x 80 mm x 10 mm Thick. Post Anchored by M12 x 150 Expanded Anchor Bolts. Post-Joineries of Mushroom Head, High-Security, Tamper Proof Nuts & Bolts in SS304, Post Finish = Pre-Galvanised up to min 150 GSM + Dual PPC Powder Coated up to min. 140 Microns in RAL 6005 (GREEN) or as approved. The entire System is 1000 Hours of Salt Spray Tested to withstand extreme climate conditions

100

-

-

... More
Design , Supply, delivery, installation & commissioning of 9 Meter GI flag mast, Flag, Rope, anchore Bolts and other accessories all complete as per the codal provisions and ISI standards as per detailed technical specification and direction of Engineer-in-charge. Mast shall be in multiple sections, suitable for wind velocity as per IS 875. Mast shall be suitable for Indian Tri colour flag size as per IS code 1. Foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates qty. India flag size as per IS Code 1 in 100% Knitted polyester (140 gsm), with reinforced super strong nylon webbing on all 3 sides and rope/toggle sleeve, complete as per direction.

16

-

-

... More
Plumbing Works Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia .Pipes.

802

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia. Pipes.

989

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia. Pipes.

1553

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 50 mm nominal outer dia. Pipes.

5381

-

-

... More
Providing, laying and jointing following u-PVC. pipes with solvent cement joint for pressures including testing of joints, cost of jointing materials and specials (i.e. socket,elbow, bends , Tee, reducers, endcap, coupler & solvent cement) ,cost of labour for laying and fixing etc. complete in all respect all complete as per detailed technical specific ations and as per direction of Engineer in charge.( Confirming to IS 4985:2000, IS 4736:1986 & IS 7634:2003(PT-3)). Minimum 8kg/sqcm. specials and fittings shall be used in the pipe line works. 50 mm dia pipe

503

-

-

... More
Providing, laying and jointing following u-PVC. pipes with solvent cement joint for pressures including testing of joints, cost of jointing materials and specials (i.e. socket,elbow, bends , Tee, reducers, endcap, coupler & solvent cement) ,cost of labour for laying and fixing etc. complete in all respect all complete as per detailed technical specific ations and as per direction of Engineer in charge.( Confirming to IS 4985:2000, IS 4736:1986 & IS 7634:2003(PT-3)). Minimum 8kg/sqcm. specials and fittings shall be used in the pipe line works. 75 mm dia pipe

3066

-

-

... More
Providing, laying and jointing following u-PVC. pipes with solvent cement joint for pressures including testing of joints, cost of jointing materials and specials (i.e. socket,elbow, bends , Tee, reducers, endcap, coupler & solvent cement) ,cost of labour for laying and fixing etc. complete in all respect all complete as per detailed technical specific ations and as per direction of Engineer in charge.( Confirming to IS 4985:2000, IS 4736:1986 & IS 7634:2003(PT-3)). Minimum 8kg/sqcm. specials and fittings shall be used in the pipe line works. 110 mm dia pipe

5778

-

-

... More
Providing, laying and jointing following u-PVC. pipes with solvent cement joint for pressures including testing of joints, cost of jointing materials and specials (i.e. socket,elbow, bends , Tee, reducers, endcap, coupler & solvent cement) ,cost of labour for laying and fixing etc. complete in all respect all complete as per detailed technical specific ations and as per direction of Engineer in charge.( Confirming to IS 4985:2000, IS 4736:1986 & IS 7634:2003(PT-3)). Minimum 8kg/sqcm. specials and fittings shall be used in the pipe line works. 160 mm dia pipe

1525

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 75 mm

131

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm

220

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 150 mm

54

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Double "Y" with or without door 75 mm

274

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Double "Y" with or without door 110 mm

270

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Vent covel 110 mm

48

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Access door cap 75 mm

310

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Access door cap 110 mm

288

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. P trap 110mmx110mm long

233

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Nahani trap 110x75mm

265

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Multi floor trap 110

80

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Plain reducing Tee 110x75mm

53

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Orissa pattern W.C. pan of size 580x440 mm

193

-

-

... More
Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White wall hung type

56

-

-

... More
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Oval or round size 550x400mm

144

-

-

... More
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: Flat back type urinal of size 460x380x250mm

137

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 560x410 mm bowl depth 215 mm.

40

-

-

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia

199

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore

93

-

-

... More
Gunmetal non-return valve - vertical (screwed end) 50 mm dia

28

-

-

... More
Gunmetal non-return valve - horizontal (screwed end) 50 mm dia

29

-

-

... More
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 32 mm nominal bore.

127

-

-

... More
Providing and fixing brass GM/ ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified. 25 mm dia

74

-

-

... More
Providing and fixing brass GM/ ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified. 50 mm nominal bore

132

-

-

... More
Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Bib cock (350 grams)

70

-

-

... More
Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Stop cock (350 grams)

70

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Long nose bib cock (500gms)

283

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Piller Cock (400 grams)

201

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bottle trap set with extension pipes

178

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Toilet paper holder

95

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Soap dish plate

110

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Towel ring (150 mm dia)

109

-

-

... More
Providing and fixing stainless steel drain jali of approved make/quality.

252

-

-

... More
Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

129

-

-

... More
Providing and fixing 600x120x5mm glass shelf with edges rounded off supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete

85

-

-

... More
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe

1338

-

-

... More
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : For 75 mm dia pipe

1215

-

-

... More
Constructing masonry Chamber 30x30x50 cm, inside with fly ash bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :

401

-

-

... More
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement: 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

93

-

-

... More
Extra for depth for manholes Size 90x80 cm

93

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx650 micron thick (0.65mm), finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.

587

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

178000

-

-

... More
Providing, laying and jointing following P.V.C. pipes with solvent cement joint for 6, 8 and 10 kg/ sq. cm. pressures including testing of joints, cost of jointing materials etc. complete in all respect. 160 mm dia.

1412

-

-

... More
Providing, laying and jointing following P.V.C. pipes with solvent cement joint for 6, 8 and 10 kg/ sq. cm. pressures including testing of joints, cost of jointing materials etc. complete in all respect. 200 mm dia.

977

-

-

... More
Providing, Solvent Cement Joints to PVC Pipes and fittings of 6, 8 and 10 Kg/Sq cm. Pressure including testing of joints and cost of jointing materials (i.e. socket, coupler & solvent cement) 160 mm dia. (8Kg/Cm2)

111

-

-

... More
Providing, Solvent Cement Joints to PVC Pipes and fittings of 6, 8 and 10 Kg/Sq cm. Pressure including testing of joints and cost of jointing materials (i.e. socket, coupler & solvent cement) 200 mm dia. (8Kg/Cm2)

98

-

-

... More
Providing and laying in position including testing following PVC bends suitable for 6, 8 and 10 Kg/Sq. cm. pressure pipes. 160 mm dia. (8Kg/Cm2)

41

-

-

... More
Providing and laying in position including testing following PVC bends suitable for 6, 8 and 10 Kg/Sq. cm. pressure pipes. 200 mm dia. (8Kg/Cm2)

41

-

-

... More
Providing and laying in position including testing following PVC flanged tail pieces suitable for 6, 8 and 10 Kg./Sq. cm. Pressure pipes. 160 mm dia. (8Kg/Cm2)

41

-

-

... More
Providing and laying in position including testing PVC coupler suitable for 6, 8 and 10 Kg/Sq. cm. Pressure pipes. 160 mm dia. (8Kg/Cm2)

41

-

-

... More
Providing and laying in position including testing PVC coupler suitable for 6, 8 and 10 Kg/Sq. cm. Pressure pipes. 200 mm dia. (8Kg/Cm2)

26

-

-

... More
Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay/ Fly ash bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :

104

-

-

... More
Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay/ Fly ash bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :

108

-

-

... More
Providing and Laying non-pressure (NP3) RCC socket & spigot pipes with rubber gasket joint including testing of joints; 250 mm dia

220

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

200

-

-

... More
Providing and fixing in position precast circular 560mm internal dia SFRC/R.C.C. manhole cover or cover and frame of approved quality: Cover and frame H D - 20

27

-

-

... More
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

24

-

-

... More
Providing and placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225mm wide, 8-11mm thick).

498

-

-

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: With 20x20 mm square bar

110

-

-

... More
Providing and fixing in position precast R.C.C. manhole cover and frame L D- 2.5 of required shape and approved quality. Rectangular shape 600x450mm internal dimensions

38

-

-

... More
Providing flanged joints to double flanged C.I./ D.I. pipes, valves and specials including rubber insertion 3mm thick, suitable bolts and nuts and testing of joints complete: 100 mm diameter pipe

72

-

-

... More
Providing, hoisting and fixing in position inverted “J‟ type 100 mm dia. C.I. Cowl type ventilators with mosquito proof aluminium mesh at top including applying 2 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge, weighing not less than 35

36

-

-

... More
Providing and laying DRIP lateral tubing of 4 kg/cm2 working pressure for single/multi Row planting below 0.3 m ground including excavation, testing and commissioning as directed with necessary fittings i.e elbow, tee,Gromate, take-off, line end, plug, adapter etc.and specials as per IS: 12786 & ISO 9001/2 certified specifications including cost of material, labour, transportation,taxes etc. complete. 16 mm Dia ( 4 Kg / Cm2)

200

-

-

... More
Inline drip 16 mm. 4 lph. 0.4mtrs. CL II -IS pc. with fittings: Supplying, erection and commissioning of inline drip of 16mm. OD LLDP lateral with pressure compensating drippers 4 lph. capacity installed inside the lateral. inline made of special grade virgin plastic marked-CL-II as per IS 13488 to be fixed with necessary accessories including all material labour, hydraulic testing and commissioning all complete as per the direction of Engineer in charge.

150

-

-

... More
Providing and fixing pressure compensating, self-flushing Emitter/Dripper of 4 ltr/hr capacity as per ISO 9002 standard and suitable for Putting Drip line 3-6" underground with necessary fittings, including cost of material, labour, transportation, taxes etc.

525

-

-

... More
Electrical Works Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and depth above 300 mm and upto 450mm made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ameters ets as per specifications including powder coating painting with busbars, switchgears and MS structure & other accessories etc complete as required as per direction of Engineer

100

-

-

... More
INCOMER 4 pole MCCB, 100 A, 35KA Microprocessor Release,35KA

4

-

-

... More
INCOMER 4P MCCB, 63A as out going 35KA

12

-

-

... More
BUS-BAR 1 Set of 100A 4P Aluminium Bus Bar with colour coded PVC Sleeves

48

-

-

... More
BUS-BAR analog type 0-500 volt voltmeter of size 100x100 (NS) (1no.)

16

-

-

... More
BUS-BAR analog type 0-100 amp ammeter of size 100x100 (NS) (1no.)

16

-

-

... More
BUS-BAR selector switch fro voltmeter (1no.)

16

-

-

... More
BUS-BAR selector switch fro ammeter (1no.)

16

-

-

... More
OUTGOINGS 4P MCCB, 40A as out going 35KA

32

-

-

... More
OUTGOINGS 4P MCB, 6-32A as out going

32

-

-

... More
Supplying and laying HDPE pipe of 4kg/cum in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 63 mm outer dia

4790

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 2 x 6 sq. mm

1860

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 2 x 10 sq. mm

1320

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 4 x 10 sq. mm.

1780

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 4 x 16 sq. mm.

6130

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 4 x 25 sq. mm.

5520

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 2 X 6 sq. mm (16 mm)

128

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 2 X 10 sq. mm (19 mm)

128

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 10 sq. mm (22 mm)

190

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 16 sq. mm (22 mm)

278

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 25 sq. mm (25 mm)

160

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

94

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

1050

-

-

... More
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

890

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as per specification.

785

-

-

... More
Supplying and fixing on surface/ recess prewired horizontal type 8 way (4 + 24), Double door, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator)

57

-

-

... More
12 /6 Nos. 6-32A SP MCB C series 10kA as out going feeder.

1368

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point

746

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point

855

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point

1176

-

-

... More
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

34

-

-

... More
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

53

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point

150

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point

173

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point

229

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point I

181

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point II

183

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point III

224

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point

92

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point

105

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point

123

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point I

124

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point II

114

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point III

131

-

-

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point

55

-

-

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point

54

-

-

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point

51

-

-

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point I

51

-

-

... More
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point II

34

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 1.5 sq. mm in 20mm conduit

10980

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 2.5 sq. mm in 20mm conduit

6560

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 4 sq. mm in 25mm conduit

3780

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 6 sq. mm in 25mm conduit

2300

-

-

... More
Supplying and fixing 2 pole and earth, 240 volts, industrial type, socket outlet, enclosed metal plug top along with SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification. 20 Amp with “C” curve MCB

35

-

-

... More
Supplying and fixing 2 pole and earth, 240 volts, industrial type, socket outlet, enclosed metal plug top along with SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification. 32 Amp with “C” curve MCB

30

-

-

... More
Supplying and fixing 2 pole and earth, 240 volts, industrial type, socket outlet, enclosed metal plug top along with SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification. 20 Amp with “C” curve TP MCB

33

-

-

... More
Supplying and fixing 2 pole and earth, 240 volts, industrial type, socket outlet, enclosed metal plug top along with SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification. 32 Amp with “C” curve TP MCB

35

-

-

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 100mmX75mm (3 Module)

389

-

-

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 125mmX75mm (4 Module)

401

-

-

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 200mmX75mm (6 Module)

361

-

-

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 125mmX125mm (8 Module)

345

-

-

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 200mmX150mm (12 Module)

265

-

-

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 3 Module

313

-

-

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 4 Module

371

-

-

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 6 Module

285

-

-

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 8 Module

281

-

-

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 12 Module

208

-

-

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 20 mm

5030

-

-

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 25 mm

5500

-

-

... More
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 32 mm

2270

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5/6 amps one way switch

438

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5/6 amps two way switch

139

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 15/16 amp switch

557

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 3 pin 5/6 amp socket outlet

335

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 6 pin 15/16 amp socket outlet

400

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 6 pin 20 amp socket outlet

149

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Fan regulator (one module size) electronic stepped type moving all rounds

122

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Fan regulator (two module size) electronic stepped type moving all rounds

658

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. RJ-45 {CAT6} socket outlet

1012

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Ceiling rose 3 pin 5 amp

1547

-

-

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Batten/ angle holder

240

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. Deluxe

39

-

-

... More
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification.

843

-

-

... More
Providing and fixing fan clamp made of 3mm thick MS flat on existing iron trusses/ girder including necessary bolts and nuts etc. as per specification.

1448

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, including connection, earthing etc. complete as per specification.

855

-

-

... More
Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 300 mm sweep

34

-

-

... More
Supplying, installation, testing and commissioning of 250/ 300 mm sweep 1400 rpm medium duty (continuous running) exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9

55

-

-

... More
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 90 cm long

855

-

-

... More
Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 12 Watt

312

-

-

... More
Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 18/20 Watt

183

-

-

... More
Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 36 watt, size 600 x 600mm

473

-

-

... More
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 18/20 watt {4 feet}

266

-

-

... More
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 36 watt {4 feet}

1295

-

-

... More
Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification.

58.5

-

-

... More
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 4mm thick anchor plate, 4 nos 24mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 10 metre high, dia 175mm at bottom and 90mm at top, base plate size 275x275x16mm, foundation bolts 750mm long

78

-

-

... More
Erection of GI octogonal pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as required. 10 metre high

78

-

-

... More
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification. Single Over Hang 1.50 metre Long

78

-

-

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 120Watt

78

-

-

... More
Design, Fabrication, Supply, Erection, Testing and commisioning of Powder coated, Weather Proof Double door type Feeder pillar fabricated out of 14 guage CRCA sheet steel in cubical, free standing, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Feeder pillar shall be treated with all anti-corrosive process before painting as per specification. Feeder Pillar shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels. Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated) INCOMER, 1No. 4 Pole 100A TPN MCCB (35 KA) , 1No. 63A FP Contactor, AOM switch & Timers for 24 Hrs. setting, Metering & Indication, 1 set of phase indicating lamps, BUS-BAR, 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves, OUTGOINGS 12 Nos. 32A SP MCB

16

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

58

-

-

... More
Supplying and laying double wall HDPE pipe having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm including excavation, dismantling of road if required and refilling the trench etc. as required. 40 mm

1980

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 3.5 x 50 sq. mm.

490

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 4 x 10 sq. mm.

1505

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as required. 3½ X 50 sq. mm (32 mm)

64

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as required. 4 X 10 sq. mm (22 mm)

96

-

-

... More
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core/ lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as required. 10 sq. mm

250

-

-

... More
Supply and drawing following sizes of FR PVC insulated copper conductor, three core cable in the existing surface/ concealed, steel/ PVC conduit as required. 3 x 1.5 sq. mm

1820

-

-

... More
Full automated Potable Water Purifier: Supplying ,installation ,testing and commissioning of Fully Automatic 25 LPH Reverse osmosis Plant with U.V and TDS Controller for drinking water purpose. The work is inclusive of all water supply fittings, connecting water supply and disposal pipe and power connections all complete as per direction of Engineer.

17

-

-

... More
Touch less Water Cooler :  Supplying ,installation ,testing and commissioning of Full Stainless steel with 2 number of taps  Contactless water drinking water dispensing Water Cooler of  Storage Capacity -80L and Cooling Capacity-40L. The work is inclusive of all water supply fittings, connecting water supply and disposal pipe and power connections all complete as per direction of Engineer.

17

-

-

... More
Grid connected Solar Photo Voltaic system : Design , engineering , supply , erection, testing and commissioning of efficient solar panels for roof top or on ground PV system ( 3 Phase ) including cost of structures for panels, suitable foundation, support systems, required Solar Photo Voltaic module poly crystalline , inverter at various desired location as detailed in specifications .The work is inclusive of balance of system including cables , switches, connectors, junction boxes, earthing , lighting arrester, cost of civil works for foundations .

17

-

-

... More
Supply , erection, testing and commissioning of net metering system for the Grid connected Solar Photo Voltaic system at various desired location as detailed in specifications and as directed by Engineer in charge.

17

-

-

... More
Fire Fighting system Supply & Fixing of CO2 type Fire Extinguisher ISI- marked confirming to IS:15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shallcomply with IS 15222.FIRE RATING:-55B. Complete with Hose Assembly and horn ,locking arrangement, operation manual,bracket with two screw and sleeve with all accessories as per approved technical specification all complete including all accessories and fittings and as per direction by Engineer-in-Charge. The rate of work is inclusive of one year Defect Liability Period. Capacity 4.5 Kg

42

-

-

... More
School Furniture Supply & Installation on Site: Student Desk, Supplying Of Dual Desk of Size 940x1025x587mm, Desktop and Seating Top - All tops shall be made out of 18mm thick Exterior grade HDHMR board ofapproved make with approved laminate finish. Top shall have edgeband of 2mm thickness with proper rounded edges with 2mm radius of approved make. Top shall be riveted to base frame. Screwing/Nailing are to be strictly avoided. Structure - Base support shall be made out of CR rectangular tube of 25mm x 50mm x 1.6mm thicknesss. Vertical support shall be CR square tube of 25mm x 25mm x 1.6mm thickness welded together with CR sheet of 1.0mm thickness so as to form a width of 150mm. Modesty panel shall be with square shape perforated CR sheet of 1.0mm thickness. Base of seating top shall be of CR tube of 18mm diameter and 1.6mm thickness. All the metal parts should be powder coated with standard thickness of 50-60 micron with color as approved by the engineer in charge. Variation of Size is allowed depend upon size of classroom.

40

-

-

... More
Supply & Installation on Site: Student Desk, Supplying Of Dual Desk of Size 1040x1060x647mm, Desktop and Seating Top - All tops shall be made out of 18mm thick Exterior grade HDHMR board of renowned company like approved makes with approved laminate finish. Top shall have edgeband of 2mm thickness with proper rounded edges with 2mm radius of renowned company like Square/Rehau/Pegasus/Equivalent industries. Top shall be riveted to base frame. Screwing/Nailing are to be strictly avoided. Structure - Base support shall be made out of CR rectangular tube of 25mm x 50mm x 1.6mm thicknesss. Vertical support shall be CR square tube of 25mm x 25mm x 1.6mm thickness welded together with CR sheet of 1.0mm thickness so as to form a width of 150mm. Modesty panel shall be with square shape perforated CR sheet of 1.0mm thickness. Base of seating top shall be of CR tube of 18mm diameter and 1.6mm thickness. All the metal parts should be powder coated with standard thickness of 50-60 micron with color as approved by the engineer in charge. Variation of Size is allowed depend upon size of classroom.

40

-

-

... More
Supply & Installation on Site: Student Desk, Supplying Of Dual Desk of 1140x1095x707mm, Desktop and Seating Top - All tops shall be made out of 18mm thick Exterior grade HDHMR board of approved makes with approved laminate finish. Top shall have edgeband of 2mm thickness with proper rounded edges with 2mm radius ofapproved makes . Top shall be riveted to base frame. Screwing/Nailing are to be strictly avoided. Structure - Base support shall be made out of CR rectangular tube of 25mm x 50mm x 1.6mm thicknesss. Vertical support shall be CR square tube of 25mm x 25mm x 1.6mm thickness welded together with CR sheet of 1.0mm thickness so as to form a width of 150mm. Modesty panel shall be with square shape perforated CR sheet of 1.0mm thickness. Base of seating top shall be of CR tube of 18mm diameter and 1.6mm thickness. All the metal parts should be powder coated with standard thickness of 50-60 micron with color as approved by the engineer in charge. Variation of Size is allowed depend upon size of classroom.

40

-

-

... More
Supply & Installation on Site: TEACHER'S TABLE WITHOUT CPU HANGER, 1200x600x750 or Suitable Size. Top and drawers shall be made out of 18mm thick Exterior grade HDHMR board of approved make with approved laminate finish and necessary hardware of of approved make . Top shall have edgeband of 2mm thickness with proper rounded edges with 2mm radius of approved make. Top shall be riveted to base frame. Structure - Top Base and Vertical support shall be made out of MS tube of 25mm x 25mm x 1.6mm thicknesss. All the metal parts should be powder coated with standard thickness of 50-60 micron with color as approved by the engineer in charge.

85

-

-

... More
Storage Steel Almirah size-1 (Providing & supplying Steel Almirah of outer size 2100 (H) X 900 (W) X 450 (D) mm made of machine pressed steel sheet and powder coated in a shade as approved. Internal Size of Almirah: 1950(H)X 900 (W) X 450 (D) mm. Leg Size ofAlmirah: 150 (H) X 120 (W) X 450 (D) mm. Rack with 5 Compartments of 4 no. of shelves. Distance between each shelf will be 360 mm. These shelves should be hanging arrangement (adjustable). Standard lock and 2 sets of keys of approved make. The thickness of the Almirah sheet shall be 1.2 mm. The body of the Almirah shall be manufactured from cold rolled MS sheet (C. R. Sheet) with Antirust treatment and shall be finished with 50-60 micron standard powder coating. The quality of used M.S sheet for making Almirah shall be free from any pitting and corrosion etc. H/D Rubber bushes shall be provided to the bottom of legs of Almirah. )

17

-

-

... More
Modular Lab Bench System(Chemistry/Bio Lab) with minimum 4 seating capacity: Island Benches of the following Dimensions according to the available space of the Lab i) Width (W)1800mmW., Ii) Depth (D) 1500mm., Iii) Height (H) Say - 900mm. Each Island Bench should be Comprising of the following Items: i) 2Nos. Of 750mmWidth, 18-20mm thick Granite work top placed on neoprene rubber sheet on the top of table frame work. ii) 4Nos. Of One piece Deep Drawn moulded 'C' Frame Legs of minimum 2.5mm thickness of galvanized (Zinc coated) GI Sheet, or equivalent as per detailed technical specifications. Arrangement for Slidable Cabinets and removable panels for maintenance for Respective entire Length of Table. iii) Mini Vertical service channel connector enabling concealed wire management from below the table to the electrical service channel. iv) 1 No. Wash Basin 600mm x 200mm made in ceramic or granite with Color as approved by Engineer in Charge.

14

-

-

... More
Modular Lab Bench System(Physics Lab ) with minimum 4 seating capacity: Island Benches of the following Dimensions according to the available space of the Lab i) Width (W)1800mmW. Ii) Depth (D) 1500mm. Iii) Height (H) Say - 900mm. Each Island Bench should be Comprising of the following Items: i) 2Nos. Of 750mmWidth, 18-20mm thick Granite work top placed on neoprene rubber sheet on the top of table frame work. ii) 4Nos. Of One piece Deep Drawn moulded 'C' Frame Legs of minimum 2.5mm thickness of galvanized (Zinc coated) GI Sheet, or equivalent as per detailed technical specifications. iii) Mini Vertical service channel connector enabling concealed wire management from below the table to the electrical service channel. Color as approved by Engineer in Charge.

35

-

-

... More
School Labrotory Equipments and accessories - (Middle School) Supply and installation of School Labrotory Equipments and accessories as per approved technical specification all complete including all accessories and fittings and as per direction by Engineer-in-Charge. Complete setup of Physic Labrotory Equipments & accessories

7

-

-

... More
Supply and installation of School Labrotory Equipments and accessories as per approved technical specification all complete including all accessories and fittings and as per direction by Engineer-in-Charge. Complete setup of Chemistry Labrotory Equipments & accessories

7

-

-

... More
Supply and installation of School Labrotory Equipments and accessories as per approved technical specification all complete including all accessories and fittings and as per direction by Engineer-in-Charge. Complete setup of Biology Labrotory Equipments & accessories

7

-

-

... More
Supply and installation of School Labrotory Equipments and accessories as per approved technical specification all complete including all accessories and fittings and as per direction by Engineer-in-Charge. Complete setup of Social science laboratory equipment and accessories

7

-

-

... More
Supply and installation of School Labrotory Equipments and accessories as per approved technical specification all complete including all accessories and fittings and as per direction by Engineer-in-Charge. Complete setup of Stem Kits and accessories :STEM lab kits ( (Science, Technology, Engineering, and Maths) . The kits are carefully designed to build new learning skills, problem solving & critical analysis skills, creativity in kids of all age groups by infusing play into education.

7

-

-

... More
Supply and installation of green board of size 8'x4' with frame Aluminium Board material resin coated steel surface as per approved technical specification all complete including all accessories and fittings and as per direction by Engineer-in-Charge.

98

-

-

... More
Building as Learning Aid Works Mural art painting: Colorful mural art painting on given surface including approved make of exterior primer and exterior grade paint on prepared surface as per direction by Engineer-in-Charge. All the painting works shall be carried out as per Building as Learning Aid concepts. i.e developing school spaces — the classrooms, the floors, walls, doors, windows, pillars, corridors, the outdoor spaces and the natural environment — as learning resources.The work is excluding providing and applying 2mm thick ready mix exterior grade approved make putty.

8000

-

-

... More
Cement art Mural work: Colorful Cement art Mural work on given surface including approved make of exterior primer and exterior grade paint on prepared surface as per direction by Engineer-in-Charge. All the works shall be carried out as per Building as Learning Aid concepts. i.e developing school spaces — the classrooms, the floors, walls, doors, windows, pillars, corridors, the outdoor spaces and the natural environment — as learning resources. The work is excluding providing and applying 2mm thick ready mix exterior grade approved make putty.

85

-

-

... More
Human and other sculptures: Colorful Cement concrete art Mural work including approved make of exterior primer and exterior grade paint on prepared surface as per direction by Engineer-in-Charge. Size 5' to 7'

17

-

-

... More
Mild steel art Mural work: Colorful Mild steel art Mural work on given surface including approved make of exterior primer and exterior grade paint on prepared surface as per direction by Engineer-in-Charge. All the works shall be carried out as per Building as Learning Aid concepts. i.e developing school spaces — the classrooms, the floors, walls, doors, windows, pillars, corridors, the outdoor spaces and the natural environment — as learning resources.

85

-

-

... More
Kids Play Equipment Providing and Installation of Four Seater See Saw: The See Saw consists of 2 poles of Dia 114mm and thickness of 2.5mm, the horizontal rod at the center which is of size 1614 mm length and Dia 114 mm. It consists of 4 seats which is made of LLDPE virgin plastic of size 364 mm X 250 mm X 180 mm. Each seat consists of a safety stand in the horizontal balance bar which is of 500 mm X 462 mm and a thickness of Dia 32 mm. Bolts, nuts, screws, washers and etc used for assembly shall be stainless steel 304 grade and shall be of tamper resistant stainless steel. Exposed hardware shall be covered with ultra violet stabilized plastic safety caps as a safety feature against protruding hardware, aesthetic pleasing against ugly exposed hardware and prevention against vandalism as well. Joints are robotic welded, as per drawing/design complete including all accessories and fittings and as per direction by Engineer-in-Charge. ALL WELDING IS CARRIED OUT BY ROBOTS, WHICH GUARANTEES STRONG AND SMOOTH WELDS ELIMINATING ANY RAG, WELD SCARS AND ENSURES THE INTEGRITY AND STRENGTH OF THE WELDED AREAS. PLAY EQUIPMENT DIMENSIONS: 2.60 m x 0.5 m x 0.7 m

16

-

-

... More
Providing and Installation of A Swing: “A” Shaped support posts of height 2.1 m are to be schedule Galvanized steel with a 80mm OD {Outer Diameter}. Toprail of length 2.58 m and Dia 76 mm shall be an all-patent welded unit, fabricated from O.D. galvanized steel pipes. Flat Swing seat of size 440 mm x 150 mm x 30 mm, Bucket Swing seat of size Dia 325 mm and height 245 mm, Plastic Components shall be rotationally molded from antistatic, copolymer, virgin linear low density UV stabilized polyethylene, with “color molded” in not “added in”. All rotational molding is carried out in state of the art, precision, bi axial roto moulding machines which helps achieve guaranteed uniform wall thickness, seamless joints, accurate process control, one part construction to make it stress free. Bolts, nuts, screws, washers and etc used for assembly shall be stainless steel 304 grade and shall be of tamper resistant stainless steel. Exposed hardware shall be covered with ultra violet stabilized plastic safety caps as a safety feature against protruding hardware, aesthetic pleasing against ugly exposed hardware and prevention against vandalism as well. Joints are robotic welded, as per drawing/design complete including all accessories and fittings and as per direction by Engineer-in-Charge. ALL WELDING IS CARRIED OUT BY ROBOTS, WHICH GUARANTEES STRONG AND SMOOTH WELDS ELIMINATING ANY RAG, WELD SCARS AND ENSURES THE INTEGRITY AND STRENGTH OF THE WELDED AREAS. PLAY EQUIPMENT DIMENSIONS: 2.5 m x 1.5 m x 2.1 m

16

-

-

... More
Providing and Installation of Monkey Bar VFM: Support posts of height 2.5 m are to be schedule Galvanized steel with a 89 mm OD {Outer Diameter}.Handrail of size 0.94 m and Dia 32 mm shall be an all-patent welded unit, fabricated from 32 O.D. galvanized steel pipes. Bolts, nuts, screws, washers and etc used for assembly shall be stainless steel 304 grade and shall be of tamper resistant stainless steel. Exposed hardware shall be covered with ultra violet stabilized plastic safety caps as a safety feature against protruding hardware, aesthetic pleasing against ugly exposed hardware and prevention against vandalism as well. Joints are robotic welded, as per drawing/design complete including all accessories and fittings and as per direction by Engineer-in-Charge. ALL WELDING IS CARRIED OUT BY ROBOTS, WHICH GUARANTEES STRONG AND SMOOTH WELDS ELIMINATING ANY RAG, WELD SCARS AND ENSURES THE INTEGRITY AND STRENGTH OF THE WELDED AREAS. PLAY EQUIPMENT DIMENSIONS: 3.20 m x 1.40 m x 2.10 m

16

-

-

... More
Providing and Installation of Merry Go Round: Thw Centre post of height 815 mm are to be schedule Galvanized steel with a 48 mm OD {Outer Diameter}. Round Deck of Dia 1.21 shall be an all-PATENT welded assembly fabricated from perforated solid punched steel. Deck perimeter is precision pre punched for attachments. Decks are pre pressed, punched, and welded, powder coated to 2.2mm thickness or vinyl plastic coated to a thickness of 4mm. Handrail of size 815 mm x 474 mm and Dia 32 mm shall be an all-patent welded unit, fabricated from 32 O.D. galvanized steel pipes. Bolts, nuts, screws, washers and etc used for assembly shall be stainless steel 304 grade and shall be of tamper resistant stainless steel. Exposed hardware shall be covered with ultra violet stabilized plastic safety caps as a safety feature against protruding hardware, aesthetic pleasing against ugly exposed hardware and prevention against vandalism as well. Joints are robotic welded, as per drawing/design complete including all accessories and fittings and as per direction by Engineer-in-Charge. ALL WELDING IS CARRIED OUT BY ROBOTS, WHICH GUARANTEES STRONG AND SMOOTH WELDS ELIMINATING ANY RAG, WELD SCARS AND ENSURES THE INTEGRITY AND STRENGTH OF THE WELDED AREAS. PLAY EQUIPMENT DIMENSIONS: Dia – 1.21 m

16

-

-

... More
Providing and Installation of 180cm Slide: “A” shaped support posts of height 2.60 m, are to be schedule Galvanized steel with a 60mm OD {Outer Diameter}. Deck of size 0.80 m x 0.60 m and Staircase of size 2.10 m x 0.60 m shall be an all-PATENT welded assembly fabricated from perforated solid punched steel. Deck perimeter is precision pre punched for attachments. Decks are pre pressed, punched, and welded, powder coated to 2.2mm thickness or vinyl plastic coated to a thickness of 4mm. Handrail of height 2.2 m and Dia 32 mm shall be an all-patent welded unit, fabricated from 32 O.D. galvanized steel pipes. Wavey Slide of size 3.54 m x 0.55 m x 2.0 m. Bolts, nuts, screws, washers and etc used for assembly shall be stainless steel 304 grade and shall be of tamper resistant stainless steel. Exposed hardware shall be covered with ultra violet stabilized plastic safety caps as a safety feature against protruding hardware, aesthetic pleasing against ugly exposed hardware and prevention against vandalism as well, as per drawing/design complete including all accessories and fittings and as per direction by Engineer-in-Charge. Joints are robotic welded. ALL WELDING IS CARRIED OUT BY ROBOTS, WHICH GUARANTEES STRONG AND SMOOTH WELDS ELIMINATING ANY RAG, WELD SCARS AND ENSURES THE INTEGRITY AND STRENGTH OF THE WELDED AREAS. PLAY EQUIPMENT DIMENSIONS: 4.85 m x 0.89 m x 2.59 m

16

-

-

... More
Providing and Installation of Multi Play System: Upright structural posts of height 2.3 m, 2.6 m and 3.1m are to be schedule Galvanized steel with a 114mm OD {Outer Diameter}. Deck of size 1.16 m x 1.16 m and Staircase of size 1.2 m x 0.60 m shall be an all-PATENT welded assembly fabricated from perforated solid punched steel. Deck perimeter is precision pre punched for attachments. Decks are pre pressed, punched, and welded, powder coated to 2.2mm thickness or vinyl plastic coated to a thickness of 4mm. Handrail of height 1.88 m and Dia 32 mm shall be an all-patent welded unit, fabricated from 32 O.D. galvanized steel pipes. Roof of size 1.47 m x 1.47 m x 0.96 m, Wavey Slide of size 1.68 m x 0.58 m x 1.23 m, Spiral Slide of size 1.31 m x 1.73 m x 2.0 m. Swing of size 2.55 m x 1.05 m shall be fabricated from 32mm O.D. galvanized steel pipe. Bolts, nuts, screws, washers and etc used for assembly shall be stainless steel 304 grade and shall be of tamper resistant stainless steel. Exposed hardware shall be covered with ultra violet stabilized plastic safety caps as a safety feature against protruding hardware, aesthetic pleasing against ugly exposed hardware and prevention against vandalism as well. Joints are robotic welded, as per drawing/design complete including all accessories and fittings and as per direction by Engineer-in-Charge. ALL WELDING IS CARRIED OUT BY ROBOTS, WHICH GUARANTEES STRONG AND SMOOTH WELDS ELIMINATING ANY RAG, WELD SCARS AND ENSURES THE INTEGRITY AND STRENGTH OF THE WELDED AREAS. PLAY EQUIPMENT DIMENSIONS: 7.5 m x 4.12 m x 4.0 m

16

-

-

... More
Providing and Fixing of Closed Mouth Dustbin for park, Height 4 feet, capacity 40 Liter, material used 5-6mm FRP Thickness, complete as per direction by Engineer-in-Charge.

102

-

-

... More
Providing & Installation of Modern Park bench, EN-3S-04-53kg-1.6mm /Capacity - 03 Person / Seating Height - 2.5 Feet / Size -5 ft X 2 ft X 3.5 ft / Bench Weight - 53 kg / Leg Type -designer Leg / Seating Frame - Powder Coated / Leg Material - Heavy Duty Cast Iron / Seating Frame - 50 X15 mm Rectangular MS Pipe (1.2mm Thick), including all accessories for jointing, sealing, complete, as per direction by Engineer-in-Charge.

102

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Front Round Table for Kids with hard fibre plastic material with excellent durability and wear resistance features. Size: 54 x 30 x 20 inches, Wt 10 kg

80

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Kids Chairs with hard fibre plastic material with excellent durability and wear resistance features, Size: ‎43.4 x 30.9 x 28.9

320

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Super Giraffe slide with hard fibre plastic material with excellent durability and wear resistance features, Size ‎145 x 35 x 25 cm; Wt. 10 kg

32

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Junior Rocker with durable frame with easy mount seats with large handle grips, Size: ‎91 x 45.6 x 29.8 cm & Wt. 7.5 kg.

80

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Magnetic Alphabet Colorful Train, Educational Model Vehicle Toys, Set of 26 Pcs A to Z. 26 wood Train car and Engines with the letters A-Z written on it. All Train car and Engines have magnetic connectors. Size 40 x 5 x 7 cm, Wt. 300gm,

64

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Magnetic Wooden Hindi Alphabets, Size: ‎19.56 x 12.7 x 4.83 cm Wt. 450gms,

64

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Fruit vegetable Toy set with basket in plastic with smooth surface and curves, Size: ‎21.9 x 16.9 x 15.6 cm, Wt: 450gms,

64

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Wire beads with Table, Size: ‎38 x 38 x 65 cm, Wt. 1 kg

48

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Number block Set (1-50) Size: 32 x 24 x 3 cm

64

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification BUILDING BLOCKS , Size ‎12 x 12 x 12 cm, Material: Fibre Plastic

64

-

-

... More
Supply of the Kids Play Equipments as per detailed technical specification Trampoline with Safety Net & U-Shape Legs for Kids, 06 Long Steel Rods, 01 Spring Cover, 01 Jumping Mat, 06 Guardrail Buckle Caps, 01 Safety Enclosure120 Net, 36 Galvanized Steel Springs, 12 Foam Tubes, 01 Spring Pulling Tool,01 Manual, 06 Circular Arc Steel Rods, 03 U-Shape Legs, 06 Suction Leg Shoes, minimum Size: 2.4m dia. Colour Multicolour, Material Polypropylene, Pad Type NET PADS, Shape Round

16

-

-

... More
Horticulture work Supply and planting of good quality approved trees with height as detailed below including transportation to site, well developed and grown condition all complete and as per direction of Engineer in charge. (excluding excavation, vermicompost, fertilizers,watering and irrigation systems). Type 1: 0.6m upto 1m height

1200

-

-

... More
Supply and planting of good quality approved trees with height as detailed below including transportation to site, well developed and grown condition all complete and as per direction of Engineer in charge. (excluding excavation, vermicompost, fertilizers,watering and irrigation systems). Type 2 : 1 to 2m height

50

-

-

... More
Supply and planting of good quality approved trees with height as detailed below including transportation to site, well developed and grown condition all complete and as per direction of Engineer in charge. (excluding excavation, vermicompost, fertilizers,watering and irrigation systems). Type 3 : 2m and above height

50

-

-

... More
Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment) all complete and as per direction of Engineer in charge.

1000

-

-

... More
Supplying of good quality vermicompost and mixing with available good earth and filling the same in required layers in excavated pit all complete and as per direction of Engineer in charge.

60000

-

-

... More
Operation and Maintenance Work First Year of Maintenance for Tree Plantation works: The work is inclusive of replanting at the location of the damaged planted trees during the course of contract maintenance period , watering of plants , deweeding, supply and application of insecticides, pesticides and fertilizers all complete and as per direction of Engineer in charge.Note: Payment shall be made on quaterly basis. Type 1: 0.6m upto 1m height In Proposed new plantation area: Note A. The quoted rate of bidder shall be 375. If quoted rate is not equal to 375, then evaluation shall be made considering the quoted rate as equal to 375 and accordingly quoted rate will be modified.

1200

-

-

... More
First Year of Maintenance for Tree Plantation works: The work is inclusive of replanting at the location of the damaged planted trees during the course of contract maintenance period , watering of plants , deweeding, supply and application of insecticides, pesticides and fertilizers all complete and as per direction of Engineer in charge.Note: Payment shall be made on quaterly basis. Type 2 : 1 to 2m height In Proposed new plantation area: Note A. The quoted rate of bidder shall be 749. If quoted rate is not equal to 749, then evaluation shall be made considering the quoted rate as equal to 749 and accordingly quoted rate will be modified.

50

-

-

... More
First Year of Maintenance for Tree Plantation works: The work is inclusive of replanting at the location of the damaged planted trees during the course of contract maintenance period, watering of plants , deweeding, supply and application of insecticides, pesticides and fertilizers all complete and as per direction of Engineer in charge.Note: Payment shall be made on quaterly basis. Type 3 : 2m and above height In Proposed new plantation area: Note A. The quoted rate of bidder shall be 1498. If quoted rate is not equal to 1498, then evaluation shall be made considering the quoted rate as equal to 1498 and accordingly quoted rate will be modified.

50

-

-

... More
First Year of Operation and Maintenance work : As per the completion cost of the subhead- work. The work is inclusive of replacement or repairing at the location of the following equipments during the course of first year contract maintenance period, including provision of a technician , fixtures and consumables all complete and as per direction of Engineer in charge. Note: Payment shall be made on quaterly basis. Note A. Subhead for this item shall be Plumbing work from above item no 118 to item no 190. Note B. The quoted rate of bidder shall be 5% of its total quoted amount of the subhead Plumbing work from above item no 118 to item no 190. If quoted rate is not equal to 5% of the total quoted amount of the subhead Plumbing work from item no 118 to item no 190, then evaluation shall be made considering the quoted rate as equal to 5% of the total quoted amount of the subhead Plumbing work from item no 118 to item no 190 and accordingly quoted rate will be modified.

1

-

-

... More
First Year of Operation and Maintenance work : As per the completion cost of the subhead- work. The work is inclusive of replacement or repairing at the location of the following equipments during the course of first year contract maintenance period, including provision of a technician , fixtures and consumables all complete and as per direction of Engineer in charge. Note: Payment shall be made on quaterly basis. Note A. Subhead for this item shall be Electrical work from above item no 191 to item no 301. Note B. The quoted rate of bidder shall be 5% of its total quoted amount of the subhead Electrical work from above item no191 to item no 301. If quoted rate is not equal to 5% of the total quoted amount of the subhead Electrical work from item no 191 to item no 301, then evaluation shall be made considering the quoted rate as equal to 5% of the total quoted amount of the subhead Electrical work from item no 191 to item no 301 and accordingly quoted rate will be modified.

1

-

-

... More
First Year of Operation and Maintenance work : As per the completion cost of the subhead- work. The work is inclusive of replacement or repairing at the location of the following equipments during the course of first year contract maintenance period, including provision of a technician , fixtures and consumables all complete and as per direction of Engineer in charge. Note: Payment shall be made on quaterly basis. Note A. Subhead for this item shall be Fire Fighting work from above item no 302. Note B. The quoted rate of bidder shall be 5% of its total quoted amount of the subhead Fire Fighting work from above item no 302. If quoted rate is not equal to 5% of the total quoted amount of the subhead Fire Fighting work from item no 302, then evaluation shall be made considering the quoted rate as equal to 5% of the total quoted amount of the subhead Fire Fighting work from item no 302 and accordingly quoted rate will be modified.

1

-

-

... More
First Year of Operation and Maintenance work : As per the completion cost of the subhead- work. The work is inclusive of replacement or repairing at the location of the following equipments during the course of first year contract maintenance period, including provision of a technician , fixtures and consumables all complete and as per direction of Engineer in charge. Note: Payment shall be made on quaterly basis. Note A. Subhead for this item shall be Furnitures work from above item no 303 to item no 309. Note B. The quoted rate of bidder shall be 5% of its total quoted amount of the subhead Furnitures work from above item no 303 to item no 309. If quoted rate is not equal to 5% of the total quoted amount of the subhead Furnitures work from item no 303 to item no 309, then evaluation shall be made considering the quoted rate as equal to 5% of the total quoted amount of the subhead Furnitures work from item no 303 to item no 309 and accordingly quoted rate will be modified.

1

-

-

... More
First Year of Operation and Maintenance work : As per the completion cost of the subhead- work. The work is inclusive of replacement or repairing at the location of the following equipments during the course of first year contract maintenance period, including provision of a technician , fixtures and consumables all complete and as per direction of Engineer in charge. Note: Payment shall be made on quaterly basis. Note A. Subhead for this item shall be Labrotory Equipments and accessories work from above item no 310 to item no 315. Note B. The quoted rate of bidder shall be 5% of its total quoted amount of the subhead Labrotory Equipments and accessories work from above item no 310 to item no 315. If quoted rate is not equal to 5% of the total quoted amount of the subhead Labrotory Equipments and accessories work from item no 310 to item no 315, then evaluation shall be made considering the quoted rate as equal to 5% of the total quoted amount of the subhead Labrotory Equipments and accessories work from item no 310 to item no 315 and accordingly quoted rate will be modified.

1

-

-

... More
First Year of Operation and Maintenance work : As per the completion cost of the subhead- work. The work is inclusive of replacement or repairing at the location of the following equipments during the course of first year contract maintenance period, including provision of a technician , fixtures and consumables all complete and as per direction of Engineer in charge. Note: Payment shall be made on quaterly basis. Note A. Subhead for this item shall be Play Equipment work from above item no 320 to item no 338. Note B. The quoted rate of bidder shall be 5% of its total quoted amount of the subhead Play Equipment work from above item no 320 to item no 338. If quoted rate is not equal to 5% of the total quoted amount of the subhead Play Equipment work from item no 320 to item no 338, then evaluation shall be made considering the quoted rate as equal to 5% of the total quoted amount of the subhead Play Equipments work from item no 320 to item no 338 and accordingly quoted rate will be modified.

1

-

-

... More
Organic waste to manure (Phase I) Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soils.

2633.35

-

-

... More
Extra for every additional lift of 1.5 m or part thereof. All types of soils

1254

-

-

... More
Extra rate for lead for every 50m lead or part thereof and upto 150 m beyond 50 m free lead and 1.5 m free lift by manual means only. For Soils

1254

-

-

... More
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).

617.46

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

4898.71

-

-

... More
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M..

4405

-

-

... More
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.

1746

-

-

... More
Supplying chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified..

1310

-

-

... More
Diluting chemical emulsion (Chlorpyriphos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm.

1009

-

-

... More
Diluting chemical emulsion (Chlorpyriphos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the intervals of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).

150

-

-

... More
Diluting chemical emulsion (Chlorpyriphos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the intervals of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).

150

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Foundations, footings, base of columns and plinth beam in any shape and size.

4212

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Columns, Pillars, Piers and likes- rectangular or square in shape

680

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)

74

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Beams, lintels, cantilevers & walls

410

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Weather shade, chhajja, Cornices and mouldings

42

-

-

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Stair cases of all types excluding spiral and folded plate type, including risers and landings

45

-

-

... More
Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured):

350

-

-

... More
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluidng cost of form work PCC 1 cement:3 coarse aggregate:6 graded stone aggregate

185

-

-

... More
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluidng cost of form work PCC 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).

22

-

-

... More
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transitmixer and concrete pump, in all works upto plinth level excluding cost of form work. M-20 Grade

160

-

-

... More
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transitmixer and concrete pump, in all works upto plinth level excluding cost of form work. M-25 Grade

690

-

-

... More
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

450

-

-

... More
Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement : 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement : 3 coarse sand) but excluding reinforcement.

225

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

65495.15

-

-

... More
DPC: Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including formwork.

5

-

-

... More
Water proofing material: Providing and mixing water proofing material in PCC/ RCC work in the proportion recommended by the manufacturer.

2700

-

-

... More
Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

34

-

-

... More
Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with sand including finishing the top smooth.

130

-

-

... More
Providing and placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225mm wide, 8-11mm thick).

63

-

-

... More
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:4 (1 cement : 4 coarse sand)

123

-

-

... More
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand)

80

-

-

... More
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

170

-

-

... More
Providing and fixing M.S. bright finished or black enameled Butt hinges IS : 1341 marked with necessary iron screws: 50x37x1.50 mm

222

-

-

... More
Providing and fixing M.S. bright finished or black enameled sliding door bolts with bolts, nuts and necessary iron screws: 250x16mm

14

-

-

... More
Providing and fixing M.S. bright finished or black enameled Tower bolts (Barrel type) with necessary iron screws: 100 mm

74

-

-

... More
Providing and fixing M.S. bright finished or black enameled handles withnecessary iron screws: 75 mm

14

-

-

... More
Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge. Extruded section Profile size 48x40 mm.

19.8

-

-

... More
Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture . M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter). PVC door shutter

7

-

-

... More
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting,hoisting, fixing in position upto a height of 5m above plinth level,consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. Electric resistance or induction butt welded tubes Grade-250, 50kg/sqm

11000

-

-

... More
Extra for hoisting trusses and placing in position over height above 5m for every 2.5 m height or part there of.

11000

-

-

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

5687.2

-

-

... More
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

348

-

-

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.

3779.4

-

-

... More
Providing and fixing M.S. frames of doors, windows, ventilators and cupboards joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Angle-iron frames

3742.2

-

-

... More
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring. (with chicken mesh pattern in of Approved design as per drawing) 80x1.20mm M.S. Laths

47.25

-

-

... More
Providing and fixing 27.5cm long wire spring for rolling shutters.

6

-

-

... More
Providing and fixing M.S. sheet top cover for rolling shutter 1.20mm thick

15.75

-

-

... More
Providing and fixing ball bearing for rolling shutters.

6

-

-

... More
Providing and fixing mechanical device chain and crank operation for operating rolling shutters.

3

-

-

... More
Providing and fixing approved pipe hand rail by welding to iron railing including applying a priming coat of red oxide zinc chromate primer. MS Pipe

112.8

-

-

... More
Providing and fixing of six/seven levers branded and approved mortise lock.

3

-

-

... More
Design, Supply and installation of DPI Flux translucent roof with standing seam multicell polycarbonate assembly of co extruded UV protected multicell panels incorporated into a complete system. Co extruded UV protected polycarbonate panel system of min 18 mm thick of 1200 mm min with with angular daylighting concept. panels shall have minimum seven layers in a truss bridge design for higher flexibility and strength. panels with opaque translucent clear combination as per required flux level and design requirements with all fixing accessories to ensure best performance for wind uplift vibration, oil canning and visual appearance. panels shall have an additional IR Blocking features for enhance thermal comfort. panels shall be manufactures with vertical standing seam at both sides of the panel. panel shall be fixed on purlin with snap on connectors with double tooth grip lock locking machanism and will be secured on MS structure (will be paid separately) with a continuous aluminium I beam holding the base of the standing seam along the length of the panel and fixed with purlin with self drilling hex head screws offering best stability with a pull out load of min 2100N tested as per ISO 6892-1998 ans IS 1608-2005 as per design requirement. Panels must IS 14443-97 shall show no sign of breakage on polycarbonate sheets which have been exposed to UV for a min of 500 Hours as per ASTM G 155. U value shall not be more than 1.9 w / m2k as per EN ISO 10077-2:2018. Panel shall be with additional end cap / Aluminum U/F profile / Glazing Bar for ends as required. Panel shall be fixed wit h over MS structutral steel / MS purline (paid separately) specification as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the Engineer in Charge.

288

-

-

... More
Extra for working height above 6 metre for fixing GI/ profile/ PVC/ polycarbonate sheet for every additional height of 1 metre of part thereof.

288

-

-

... More
Providing and making 6mm thick cement plaster of mix: In Cement Mortar 1:4 (1 cement : 4 fine sand)

94.8

-

-

... More
Providing and making 12mm thick cement plaster of mix: In cement Mortar 1:3 (1 cement : 3 fine sand)

62.54

-

-

... More
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:4 (1 cement : 4 fine sand)

570.67

-

-

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:4 (1 cement : 4 fine sand)

1039.25

-

-

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

1440.95

-

-

... More
Providing and making 6mm thick cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and a thick coat of lime wash on top of wall when dry for bearing of R.C.C. slab and beam.

18.84

-

-

... More
Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer.(POWDER)

312.7

-

-

... More
Making grove in cement plaster while plastering upto10 mm deep and 10 mm wide.

4098

-

-

... More
Applying cement slurry on R.C.C. slab or cement concrete work using 2.75 kg/ sqm for receiving cement concrete floor including roughening cleaning etc complete.

983.36

-

-

... More
25mm thick cement concrete flooring with 1:2:4 cement concrete (1cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with floating cost of neat cement.

33.6

-

-

... More
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 75 mm thick

949.76

-

-

... More
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size above 200x300mm

388.87

-

-

... More
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. Size 300x300mm

21.53

-

-

... More
Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete Upto 2 mm thickness to make surface even and smooth in line and level.

296.52

-

-

... More
Providing and applying plaster of paris putty over plastered ceiling surface including scaffolding complete. Upto 2 mm thickness to make surface even and smooth in line and level.

72

-

-

... More
Distempering with acrylic washable distemper to give an even shade On new work (Three or more coats)

368.52

-

-

... More
Wall painting with acrylic premium emulsion (plastic) paint of required shade to give an even shade. On new work (two or more coats)

1366

-

-

... More
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.

589.25

-

-

... More
Providing and applying 2mm thick ready mix exterior grade approved make putty on walls to make the surface smooth and even.

589.25

-

-

... More
Finishing walls with water proofing cement paint of required shade to give an even shade. On new work (Two or more coats applied @ 3.84 kg/10 sqm)

589.25

-

-

... More
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint (top most approved branded quality)

25.92

-

-

... More
Applying priming coat on steel work with red oxide zinc chromate primer.

1677.21

-

-

... More
Painting on new work (two or more coats) to give an even shade with: Premium synthetic enamel paint

1887.21

-

-

... More
Excavation in Soil (by Mechanical Means.);Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300.

1930.83

-

-

... More
Construction of embankment / sub-grade with Material Obtained from Borrow Pits (Construction of embankment with approved material/selected soil having C.B.R. 10 (unless specified otherwise in the contract) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)

983.42

-

-

... More
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401; A Plant mix method (with Mechanically crushed stone only) (iii) for grading-VI Material.

480.62

-

-

... More
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)

393.37

-

-

... More
Providing and fixing factory made confirm to all technical specification of Bureau of Indian standards 15658 of 2006 for heavy duty pavers resulting in consistent and uniform quality , rubber molded, white cement based, pigmented block lacquer coating & cured through drying process mechanically vibrated and compacted pre cast interlocking premium pavers blocks in M40 grade, 60mm thickness of approved size, design and colour with providing and laying in position over cement mortar(1:3) of 25mm avg. thhickness.

512.38

-

-

... More
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement as per IRC:58 over a prepared sub-base, coarse and fine aggregate conforming to IS:383 and graded as per table 600-3 mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per clause 602.) 9 (ii)With Cement concrete grade M-30 and minimum cement content @ 375 kg/cum.

289

-

-

... More
Supplying and laying following sizes one number PVC insulated, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 4 x 16 sq. mm.

150

-

-

... More
Supply, installation, testing and commissioning of cubicle type wall/ floor mounted power cum control panel made out of not less than 1.6mm thick MS.sheet & comprising of following panel mounting switch gears there in including connection inter-connection etc. as required. a) Phase indicating lamps with fuses and toggle switches 1 set b) Star-delta starter suitable for 5 HP 3 phase AC induction motor with over load and no volt relay c) 32 A "C" series TPMCB 1 No d) Voltmeter 0-500 V with selector switch 1 set e) Ammeter 0-10 A with CT's and selector switch 1 set.

3

-

-

... More
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. Size : 50 mm dia pipe

10

-

-

... More
Extra for providing and mixing water proofing Chemical in cement plaster work in proportion as recommended by manufacturer. (Liquid)

36.4

-

-

... More
Self Supported Galvalume Trustless Roofing / wall claddings: Design, Supplying and Installation of Self Supported Arch Shaped Galvalume Roofing / wall claddings made up of Superior Quality Structural Grade Steel, having Base Metal Thicknesses ranging from 0.80MM to 1.60MM, Thickness Tolerance (+/- 0.03MM), Coil Width of 912MM (+/- 2 MM), and, Profile width of 625 MM (+/- 10MM). Color Coated Galvalume Sheets complied to ASTM A792 Standards with Coating mass AZ 150, Yield Strength 350 mPA minimum to be used. Fabrication and Installation of Self Supported Roofing to be carried out using Hydraulic Profile Machines and joined by mechanical seamers only.The Roofing sheets should support the roof top solar panels with the Solar Alumunium Rail Structure with proper spacing and approved arrangements. Material : Color Coated Galvalume Sheet -ASTM A792; Std. Material Specification : Product : Galvalume Coil; SKU 1.20 MM BM x mm X 912mm , Grade: Substrate as per ASTM 792 M ; 340 Class 2. Coating: AZM150 , Paint Thickness: Top Coat (25microns nominal including Primer) Bottom Coat (10microns nominal including Primer Material Specification : Color coated Galvalume sheet, BMT: 1.20 MM, APT: 1.25 MM, Tolerance : +/- 0.04 mm (Consumption @12.56 Kgs Per SQM), (Coil Width 912MM , Panel Width 620MM) The work is inclusive of Anchor Bolts & Fasteners, Washers, with required fittings as per Proflex system, Epoxy - Epilux 610 Primer- Catalyse de poxy resin/ Zinc Phosphate, Rubber Paint - Bipson HB Zinc Phosphate Primer - Modified Alkyd medium pigmented with zinc Phosphate. inclusive of scaffolding, lifting fixing of the item at various levels for all heights and leads as per design and drawings all complete as per detailed technical specification and direction of Engineer-in-charge. Note: This item shall be executed by specialized agency approved by NRANCCL based on the submitted criteria as per tender conditions. The above item is inclusive of approved colour pigment of the cladding material. Shop drawings for the elevation and fixing arrangement should be approved by Engineer in charge of NRANCCL. Design and fixing of support systems shall be under the scope of contractor. Mode of Measurement: The roofing shall be measured for its curved surface area. The length and breadth shall be measured correct to a cm.The thickness shall not be less than that specified.

1750

-

-

... More
Solar Alumunium Rail Structure: Supply and installation of Alumunium self supported Studs to support the roof top solar panels, the studs should be installed on the roof top with proper spacing and approved arrangements. The arrangement should be Dual Axis Adjustable 2.5mm thick Aluminium Rail Structures, which supports for mounting Solar Panel in an easier way. The item is inclusive of all the necessary fitting, support system with all complete accessories as per the detailed technical specification, as per direction of Engineer In charge. The self supported Stud arrangement shall be approved from the authority.

800

-

-

... More
Providing Fixing 5 mm thick transparent white acrylic plastic sheets of approved quality in window with fastners, rubber, gripper stiffners complete as per the detailed technical specification, as per direction of Engineer In charge.

106.92

-

-

... More
Supply of Fertilizer Packing Bags of Premium quality Biaxially Oriented Polypropylene ( BOPP) fabrics with appropriate thickness, high quality printed Leveling pattern . The Bags shall be Waterproof, Fine finish and Tear resistance all complete as per the detailed technical specification and as per direction of Engineer In charge. 1 Kg Bag

1000

-

-

... More
Supply of Fertilizer Packing Bags of Premium quality Biaxially Oriented Polypropylene ( BOPP) fabrics with appropriate thickness, high quality printed Leveling pattern . The Bags shall be Waterproof, Fine finish and Tear resistance all complete as per the detailed technical specification and as per direction of Engineer In charge. 2 Kg Bag

1000

-

-

... More
Supply of Fertilizer Packing Bags of Premium quality Biaxially Oriented Polypropylene ( BOPP) fabrics with appropriate thickness, high quality printed Leveling pattern . The Bags shall be Waterproof, Fine finish and Tear resistance all complete as per the detailed technical specification and as per direction of Engineer In charge. 5 Kg Bag

1000

-

-

... More
Supply of Fertilizer Packing Bags of Premium quality Biaxially Oriented Polypropylene ( BOPP) fabrics with appropriate thickness, high quality printed Leveling pattern . The Bags shall be Waterproof, Fine finish and Tear resistance all complete as per the detailed technical specification and as per direction of Engineer In charge. 10 Kg Bag

1000

-

-

... More
Supply of Fertilizer Packing Bags of Premium quality Biaxially Oriented Polypropylene ( BOPP) fabrics with appropriate thickness, high quality printed Leveling pattern . The Bags shall be Waterproof, Fine finish and Tear resistance all complete as per the detailed technical specification and as per direction of Engineer In charge. 25 Kg Bag

1000

-

-

... More
Plumbing Works - OWM-I Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Orissa pattern W.C. pan of size 580x440 mm

2

-

-

... More
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: Flat back type urinal of size 460x380x250mm

3

-

-

... More
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x400 mm

4

-

-

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia

4

-

-

... More
Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

2

-

-

... More
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe

24

-

-

... More
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : For 75 mm dia pipe

24

-

-

... More
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. For 75 mm dia pipe

50

-

-

... More
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. For 110 mm dia pipe

84

-

-

... More
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. For 150 mm dia pipe

10

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 75 mm

8

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm

8

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 150 mm

2

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Double "Y" with or without door 75 mm

2

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Double "Y" with or without door 110 mm

2

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Vent covel 110 mm

3

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Access door cap 75 mm

3

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Access door cap 110 mm

3

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. P trap 110mmx110mm long

2

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Nahani trap 110x75mm

2

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Multi floor trap 110

9

-

-

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Plain reducing Tee 110x75mm

3

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia .Pipes.

20

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia. Pipes.

20

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia. Pipes.

182.21

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 50 mm nominal outer dia. Pipes.

419

-

-

... More
Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Bib cock (350 grams)

2

-

-

... More
Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Stop cock (350 grams)

5

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Long nose bib cock (500gms)

8

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Piller Cock (400 grams)

4

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bottle trap set with extension pipes

4

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Soap dish plate

2

-

-

... More
Providing and fixing stainless steel drain jali of approved make/quality.

12

-

-

... More
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 32 mm nominal bore.

8

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore

2

-

-

... More
Providing flanged joints to double flanged C.I./ D.I. pipes, valves and specials including rubber insertion 3mm thick, suitable bolts and nuts and testing of joints complete: 100 mm diameter pipe

12

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank .

4000

-

-

... More
Constructing masonry Chamber 30x30x50 cm, inside with fly ash bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :

5

-

-

... More
Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay/ Fly ash bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :

2

-

-

... More
Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay/ Fly ash bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :

6

-

-

... More
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement: 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

4

-

-

... More
Extra for depth for manholes Size 90x80 cm

4

-

-

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: With 20x20 mm square bar

24

-

-

... More
Providing and fixing in position precast R.C.C. manhole cover and frame L D- 2.5 of required shape and approved quality. Rectangular shape 600x450mm internal dimensions

6

-

-

... More
Supply, erection, jointing, testing & commissioning of "C" Class MS pipes (as per IS: 1239) including necessary specials such as tees, bends, flanges reducers etc., complete on wall/ ceiling. The pipes to be erected on wall or suspended from beams, RCC roof slabs with suitable size MS bars/ angle irons including painting of metal part except pipe line. 50mm dia.

50

-

-

... More
Supply, erection, jointing, testing & commissioning of "C" Class MS pipes (as per IS: 1239) including necessary specials such as tees, bends, flanges reducers etc., complete on wall/ ceiling. The pipes to be erected on wall or suspended from beams, RCC roof slabs with suitable size MS bars/ angle irons including painting of metal part except pipe line. 80mm dia.

100

-

-

... More
Painting for M.S. pipe with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. 50mm dia

50

-

-

... More
Painting for M.S. pipe with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. 80mm dia

100

-

-

... More
Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 150mm dia

1

-

-

... More
upplying, fixing, testing and commissioning of flanged butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS: 13095 of following sizes as required. 150mm dia

1

-

-

... More
Providing and fixing C.I. double flanged sluice valves rated to PN 1.6 with C.I. Wheel bolts, nuts, washers 3mm thick insertion rubber gasket including matching flanges table E, complete. 150mm dia

1

-

-

... More
Providing and fixing brass GM/ ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified. 25 mm dia

2

-

-

... More
Providing and fixing brass GM/ ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified. 50 mm nominal bore

7

-

-

... More
Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in approved manner.

6

-

-

... More
Supply and erecting following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. ABC type 4 kg

6

-

-

... More
Supply and erecting following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. ABC type 6 kg

6

-

-

... More
Providing, laying and jointing following P.V.C. pipes with solvent cement joint for 6, 8 and 10 kg/ sq. cm. pressures including testing of joints, cost of jointing materials etc. complete in all respect. 160 mm dia.

230

-

-

... More
Providing, laying and jointing following P.V.C. pipes with solvent cement joint for 6, 8 and 10 kg/ sq. cm. pressures including testing of joints, cost of jointing materials etc. complete in all respect. 200 mm dia.

32

-

-

... More
Providing, Solvent Cement Joints to PVC Pipes and fittings of 6, 8 and 10 Kg/Sq cm. Pressure including testing of joints and cost of jointing materials (i.e. socket, coupler & solvent cement) 160 mm dia. (8Kg/Cm2)

10

-

-

... More
Providing, Solvent Cement Joints to PVC Pipes and fittings of 6, 8 and 10 Kg/Sq cm. Pressure including testing of joints and cost of jointing materials (i.e. socket, coupler & solvent cement) 200 mm dia. (8Kg/Cm2)

2

-

-

... More
Providing and laying in position including testing following PVC bends suitable for 6, 8 and 10 Kg/Sq. cm. pressure pipes. 160 mm dia. (8Kg/Cm2)

5

-

-

... More
Providing and laying in position including testing following PVC bends suitable for 6, 8 and 10 Kg/Sq. cm. pressure pipes. 200 mm dia. (8Kg/Cm2)

2

-

-

... More
Providing and laying in position including testing following PVC flanged tail pieces suitable for 6, 8 and 10 Kg./Sq. cm. Pressure pipes. 160 mm dia. (8Kg/Cm2)

2

-

-

... More
Providing and laying in position including testing PVC coupler suitable for 6, 8 and 10 Kg/Sq. cm. Pressure pipes. 160 mm dia. (8Kg/Cm2)

2

-

-

... More
Providing & fixing of Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. (Steel Spindle) Sluice Valve/Scour valve 50mm dia, PN-1.6

3

-

-

... More
Providing & fixing of Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. (Steel Spindle) Sluice Valve/Scour valve 80 mm dia. PN-1.6.

6

-

-

... More
Providing & fixing following cast iron double flanged single door reflux (non return) valves including jointing & testing with cost of jointing material such as bolts,nuts and rubber insertion all complete as per IS :5312 (Part I) 50mm dia. (Class -PN 1.0 rating)

2

-

-

... More
Providing & fixing following cast iron double flanged single door reflux (non return) valves including jointing & testing with cost of jointing material such as bolts,nuts and rubber insertion all complete as per IS :5312 (Part I) 80mm dia. (Class -PN 1.0 rating)

4

-

-

... More
Providing & fixing following cast iron double acting air valves, flanged with out inbuilt isolating valve asper IS : 14845-2000 including jointing &testing with cost of jointing material and rubber insertion all complete asper IS :13095-1991 50mm dia. PN-1.6

1

-

-

... More
Providing & fixing following cast iron double acting air valves, flanged with out inbuilt isolating valve asper IS : 14845-2000 including jointing &testing with cost of jointing material and rubber insertion all complete asper IS :13095-1991 80mm dia. PN-1.6

2

-

-

... More
Fabrication of M.S. pipes & specials fromsteel plates as per relevant IS specifications inclusive of cost of all materials, for any thickness as per design, inspection charges, testing, transit insurance, loading/ unloading, FOR site and stacking etc. complete as per direction of the Engineer in charge. fabricating of pipes and specials fromsteel plates. Fabricating pipes from steel plates

150

-

-

... More
Providing and Laying non-pressure (NP3) RCC socket & spigot pipes with rubber gasket joint including testing of joints. 250 mm dia

26

-

-

... More
Providing and Laying non-pressure (NP3) RCC socket & spigot pipes with rubber gasket joint including testing of joints. 450 mm dia

15

-

-

... More
cubicle type compartmentalized

4

-

-

... More
Gunmetal non-return valve - vertical (screwed end) 50 mm dia

2

-

-

... More
Gunmetal non-return valve - horizontal (screwed end) 50 mm dia

2

-

-

... More
Electrification works Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and 900mm (NS) deep made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ameters ets as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as required for completeness and as per attached specification, direction of Engineer, CGPWD standards and Electrical Inspectorate standards.The panel will be extension of existing LT panel LOCATED at STP-2 INCOMER, 2 No. 400A FP MCCB(50 KA) , Metering & Indication, 1 set of phase indicating lamps, 1 set of (0-500V) Voltmeter with VSS, 1 set of (0-500A) Ammeter with ASS with 3 no s.400/5A CTs, BUS-BAR, 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves and the Bus bar shall be interconnection with existing bus bar of LT panel located at STP-2 , OUTGOINGS, 6 No. 40A, DP MCB & 5 No.40 A TP MCB, 3 Nos. 100A, 4P MCCB (35KA)., 12 Nos. 63A, 4P MCCB (35KA).

1

-

-

... More
Supplying, installation, testing and commissioning of industrial Insect Killer machine as per detailed technical specification including power supply systems all complete as per direction of Engineer In charge. It should be user-friendly operation, nontoxic properties, low power consumption, and maintenance free lifetime. For human safety glass fuse & on/off Rocker with power indicator has provided of Approved Make . Specification : Machine Body : Stainless Steel Fitting: Wall/Ceiling , Number of Tubes 4, Fitting Wall/Ceiling, Machine Size: 25" x 9" x 30" , UV Tubes 2 Feet /18 Watt ( Philips / Osram ), Power Consumption 110 Watt, Minimum Effective Area 1500 Sq. Ft.

8

-

-

... More
Structural steel hot dip galvinized MS angle welded over a base plate including cutting, welding ,hoisting and fixing in position with 3 nos. of 12mm diameter fastners etc. complete as per drawings and direction of Engineer complete etc.

300

-

-

... More
Supplying and laying HDPE pipe of 4kg/sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as required. 200 mm outer dia

150

-

-

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as required. 3.5 x 400 sq. mm.

824

-

-

... More
Supply, installation, testing and commissioning of ATS Panel 400 Amp 4 Pole 50 KA with Overlapped Neutral facility. The ATS Controller should have communication facility.

1

-

-

... More
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and 900mm (NS) deep made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ameters ets as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as required for completeness and as per attached specification, direction of Engineer, CGPWD standards and Electrical Inspectorate standards. (Only face area is to be measured) INCOMER, 2 No. 400A FP MCCB(35 KA) ( 1 for main incomer and other for solar ), Metering & Indication, 1 set of phase indicating lamps, 1 set of (0-500V) Voltmeter with VSS, 1 set of (0-500A) Ammeter with ASS with 3 no s.400/5A CTs, BUS-BAR, 1 Set of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves, OUTGOINGS, 6 No. 40A, DP MCB & 5 No.40 A TP MCB, 3 Nos. 100A, 4P MCCB (35KA)., 12 Nos. 63A, 4P MCCB (35KA).

1

-

-

... More
Supplying and laying double wall HDPE pipe having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 100 cm excluding excavation, dismantling of road if required and refilling the trench etc. as required. Size : 40 mm Outer dia.

730

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 3.5 x 50 sq. mm.

251

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 4 x 10 sq. mm.

207

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 4 x 16 sq. mm.

200

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 4 x 25 sq. mm.

240

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 2 x 6 sq. mm

200

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 2 x 10 sq. mm

150.1

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 2 X 6 sq. mm (16 mm)

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 2 X 10 sq. mm (19 mm)

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 10 sq. mm (22 mm)

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 16 sq. mm (22 mm)

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 25 sq. mm (25 mm)

8

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3.5 x 50 sq. mm.

6

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point

50

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point

40

-

-

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point

45

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point

10

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point

10

-

-

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point

15

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point

6

-

-

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point

10

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 1.5 sq. mm in 20mm conduit

792

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 2.5 sq. mm in 20mm conduit

350

-

-

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 4 sq. mm in 25mm conduit

200

-

-

... More
Supplying and fixing metal box of following sizes (nominal size) in recess with suitable size phenolic laminated sheet cover in front including painting etc. as required. 75mmX75mmX60mm deep

25

-

-

... More
Supplying and fixing metal box of following sizes (nominal size) in recess with suitable size phenolic laminated sheet cover in front including painting etc. as required. 100mmX100mmX60mm deep

24

-

-

... More
Supplying and fixing following piano type switch, socket, other accessories on the existing switch box/ cover including connections etc. as required. Bell push

1

-

-

... More
Supplying and fixing following piano type switch, socket, other accessories on the existing switch box/ cover including connections etc. as required. Fan regulator electronic, step type moving all round

20

-

-

... More
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, earthing etc. complete as required 1200 mm sweep

10

-

-

... More
Providing and fixing fan clamp made of 3mm thick MS flat on existing iron trusses/ girder including necessary bolts and nuts etc. as required.

20

-

-

... More
Surface LED light : Supplying, installation, testing and commissioning of LED light high bay light 80 watts

50

-

-

... More
Surface LED light : Supplying, installation, testing and commissioning of 40 W +/- 5% LED 4Ft LED batten having 4000 lm system lumen output. LED Batten shall be Co-extruded channel in thermally conductive material with plastic colour. LED batten shall have HET diffuser to provide uniform light distribution. LED batten shall use lower wattage of multiple LEDs over complete length of tube to create uniform light distribution with minimum guaranteed lumen output of 4000 lm from LEDs. The LED shall be compliant with LM80-08 standard with Useful L70 life of = 50000 Hrs. The LEDs used in LED Tube Light should be with CCT of 6500 K and CRI of Minimum 70. LED batten shall have isolated type multi stage Constant Current Constant voltage driver suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with minimum 5 KV surge protection, Power factor shall be greater than 0.9 and total harmonic distortion (THD) of less than 20%. and furnishing 2 Yrs Guarantee certificate from manufacturer (Baton type 36w Integral sleek extruded aluminium LED channel with white acrylic cover )

15

-

-

... More
Supplying and fixing 3 pin, 5 amp ceiling rose of approved make and ISI quality on the existing metal box including connections along with accessories, hardwares etc as required for competeness and as per attached specification, direction of Engineer, CGPWD standards and Electrical Inspectorate standards.

20

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

6

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as required.

60

-

-

... More
Supplying and fixing of 32mm dia x 2 metre long G.I pipe (light) bracket for mounting street light fittings of all types on poles including bending the pipe to the required shape, 2 Nos 40x3mm flat iron clamps with bolts and nuts including wiring with 1.5 sq. mm W.P /PVC wire etc. as required.

6

-

-

... More
Supplying and fixing on surface/ recess prewired horizontal type 8 way (4+24)double door, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland plate, loose wire box, superior make terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as required 3P MCCB, 63A 8 NOS as out going 35KA , 6-32A SP MCB C series 10kA as out going feeder.

2

-

-

... More
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043-1987 made of corrosion free G.I.Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as required: With 2 metre long GI Pipes and 25 kg back filling compound.

6

-

-

... More
CO2 type Fire Extinguisher ISI marked : Confirming to IS :15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shallcomply with IS 15222.FIRE RATING:-55B. Complete with Hose Assembly and horn ,locking arrangement, operation manual,bracket with two screw and sleeve

6

-

-

... More
Providing and erecting floor mounted sand/ water bucket stand for keeping 4 nos. of fire bucket, 1500 mm in length and 900 mm in height made out of 30 X 30 X 4 mm angle iron welded with 4 hooks and duly painted with one coat of zinc cromate primer and 2 coat of synthetic enamel paint of post box red colour etc complete

4

-

-

... More
Supplying and installing following size powder coated, perforated M.S. cable trays with perforation not more than 17.5% rigidly suspended from the ceiling with M.S. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc all complete as required. 225 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
Supplying and fixing of following sizes powder coated, perforated, M.S. cable trays bends (horizontal) turning at 900 in same plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as required. 225 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
Area Lighting : Supply of hot dipped galvanized (in single dip to average 65 micron) octoganal pole made of 3mm thick steel sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade. (designed for wind speed upto 150km/hr) 7 metre high, dia 130mm at bottom and 70mm at top, base plate size 220x220x12mm, foundation bolts 700mm long

17

-

-

... More
Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement (minimum 90kg per cum), form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required

8.5

-

-

... More
Erection of GI octogonal/ tubular pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as required : 7 metre high

17

-

-

... More
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy,painting with one coat of approved steel primer etc. as required. Single Over Hang 1.0 metre Long

17

-

-

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protectionand 5 KV surge protection on pole bracket complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 45 watt

17

-

-

... More
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ concealed, steel/ PVC conduit/ PVC casing caping as required. 3 x 1.5 sq. mm

150

-

-

... More
Earthing with G.I. earth pipe 3.0 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.

20

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering,excavation and refilling the trench etc. as required.

120

-

-

... More
Design, Fabrication, Supply, Erection, Testing and commisioning of Powder coated, Weather Proof Double door type Feeder pillar fabricated out of 14 guage CRCA sheet steel in cubical, free standing, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Feeder pillar shall be treated with all anti-corrosive process before painting as per specification. Feeder Pillar shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated) Feeder Pillar:, INCOMER,1No. 63A FP MCCB(35 KA) , 1No. 63A FP Contactor, AOM switch & Timers for 24 Hrs. setting, Metering & Indication, 1 set of phase indicating lamps, BUS-BAR, 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves, 4 nos 32 A TP MCB and 8 nos 6 to 32 amp SP MCB

1

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 3.5 x 50 sq. mm.

50

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 4 x 10 sq. mm.

450

-

-

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 2 x 6 sq. mm.

100

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as required. 3½ X 50 sq. mm (32 mm)

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as required. 4 X 10 sq. mm (22 mm)

6

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as required. 2 x 6 sq. mm.

8

-

-

... More
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core/ lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as required. 10 sq. mm

12.5

-

-

... More
CCTV Works : SITC of The IP Rugged dome camera shall be equipped with a 1/2.7″ 5 MP progressive scan CMOS imager to capture 5MP (25/30 fps)//2560 × 1920 (20fps) images; 2.8 -12 MM, MFZ Lens, DIGITAL ZOOM 16x and a waterproof (IP66) IK10 impact-resistant camera housing, As a true day/night solution, the camera shall use Smart IR technology and provide up to 98 ft (30 m) of IR illumination. The camera shall accept PoE (802.3af) or 12 V DC power input.Min. Illumination:-0.03 lux color @ F1.4 (Color, 1/3s, 30 IRE),0 lux B/W with IR LEDs on @ F2.0).Video compression :- H.265 , Noise Reduction: 3DNR,Backlight Comensation :- True WDR 120 DB,ANGLE OF VIEW 88°/30° (H), 65°/23° (V) ,UL listed. 16 Channel NVR with 2 SATA as per direction of Engineer In chargeand as of approved make.

6

-

-

... More
SITC of 16 Channel NVR With 1080p Realtime Live View H.265/H.264 MJPEG dual codec decoding Up to 12 MP resolution preview & playback Max 320 Mbps incoming bandwidth support 2 SATA HDDs up to 12TB, Supports fisheye videode-warping in local and web user interface,Supports visual or auditory notifications(a flashing light, bell,or siren) 24 Port POE Switch with 2 SFP Ports as per direction of Engineer In charge.

1

-

-

... More
SITC of 24 port POE Switch with 4 SFP ports; having security features like Port Security supports 64 MACs per port; • Auto Surveillance VLAN; Loopback Detection automatically disables a port when a loop is detected; Cable Diagnostics allows administrators to determine cable status; • UTP Cat. 5, Cat. 5e (100 m max.); • Full/Half-duplex for 10/100 Mbps• Full-duplex for 1000 Mbps; • Auto MDI/MDIX adjustment for all twisted-pair ports; Switching Capacity • 56 Gbps ; Maximum 64 bytes packet forwarding rate • 41.7Mpps ; • Ports 1 to 24 compliant with 802.3 at Network racks, display and storage device all complete as per direction of Engineer In charge

1

-

-

... More
Supply, installation, testing and commissioning off 9U Rack for mounting switches, Patch Panels,. Network rack shall be along with Spike, Fan tray , Cable Manager as required all complete as per direction of Engineer In charge.

1

-

-

... More
Supplying,installation,testing and commissioing of following size LED Monitor,table/wall mount with in build speaker minimum 5Wx2,with minimum 1No of HDMI and USB port including remote control,connecting cable,batteries,and all accessories,connection etc complete as per specification

1

-

-

... More
Supply, installation, testing and commissioning of 6 TB survelliance Harddisk Cabling all complete as per direction of Engineer In charge.

2

-

-

... More
Supply, installation, testing and commissioning of Giga Speed Category 6 Non plenum U/UTP cable, Color state /CAT 6 cable in existing conduit all complete as per direction of Engineer In charge.

500

-

-

... More
Supply, installation, testing and commissioning of 3 Meter HDMI cables all complete as per direction of Engineer In charge.

4

-

-

... More
Supplying and Installation of Media Converter (Fiber to Cat-6) all complete as per direction of Engineer In charge.

1

-

-

... More
Supply, installation, testing and commissioning of 1KVA 230 volts OFF-LINE UPS (sine wave) with built-in SMF (Sealed Maintenance Free) lead acid battery for half an hour back-up including connection as required all complete as per direction of Engineer In charge.

1

-

-

... More
Supplying, installation, testing and commissioning of 5 Blade In dustrial high-volume low-speed Ceiling Fan as per detailed technical specification including power supply systems all complete as per direction of Engineer In charge. HVLS fans produce a massive, cylindrical column of air that flows down to the floor and outward in all directions, consistently circulating air in large spaces.The 5-blade design optimizes airflow by increasing lift off of the blade surface. It should have Remote digital touch screen offers floor-level diagnostics and the Single-axis mount decreases potential fan movement. In the colder months, HVLS ceiling fans can be run in reverse to circulate the hot air trapped at ceiling level. Specification: Material - Aluminium Blades, Power supply : 3 Phase, Number of Blades- 5 , Noise Level- 53 dB, Motor Power -0.5 hp, Overall Weight -90 lbs (41 kgs), Airflow -45,000 CFM, Maximum Speed -120 RPM, Power Usage- 450 W

1

-

-

... More
Supplying, installation, testing and commissioning of following heavy duty Axial Fan 1 Hp including necessary bolts and nuts etc. as required Sweep – 24 inches DIA, Capacity- 10500 M3/Hour Free air delivery, Drive- Direct impeller mounted on motor shaft, Material- M.S for Tube, Cast aerofoiled section dynamically balanced aluminium for Impeller and SS- 304. for bird screen on both sides with complete anodized nuts and bolts. Motor- 1HP X 1440 RPM Std TEFC electric motor, IP 55 enclosure, “F” Class insulation suitable for 415/3/50 AC supply. The item is inclusive of necessary bolts and nuts etc. as required all complete as per technical specification of approved make and direction of Engineer In charge.

15

-

-

... More
Full automated Potable Water Purifier: Supplying ,installation ,testing and commissioning of Fully Automatic 25 LPH Reverse osmosis Plant with U.V and TDS Controller for drinking water purpose. The work is inclusive of all water supply fittings, connecting water supply and disposal pipe and power connections all complete as per direction of Engineer.

1

-

-

... More
Touch less Water Cooler :  Supplying ,installation ,testing and commissioning of Full Stainless steel with 2 number of taps  Contactless water drinking water dispensing Water Cooler of  Storage Capacity -80L and Cooling Capacity-40L. The work is inclusive of all water supply fittings, connecting water supply and disposal pipe and power connections all complete as per direction of Engineer.

1

-

-

... More
Grid connected Solar Photo Voltaic system : Design , engineering , supply , erection, testing and commissioning of efficient solar panels for roof top or on ground PV system ( 3 Phase ) including cost of structures for panels, suitable foundation, support systems, required Solar Photo Voltaic module poly crystalline , inverter at various desired location as detailed in specifications .The work is inclusive of balance of system including cables , switches, connectors, junction boxes, earthing , lighting arrester, cost of civil works for foundations .

10

-

-

... More
Supply , erection, testing and commissioning of net metering system for the Grid connected Solar Photo Voltaic system at various desired location as detailed in specifications and as directed by Engineer in charge.

10

-

-

... More
Supply of Compactor, Bucket Grabber & suction cum jetting machine Supply of " Refuse compactor mounted on truck chassis" as per detailed technical specification and approved make for waste collection, management and disposal purpose as per instruction of Engineer In charge.

1

-

-

... More
Supply of "Sewer suction cum jetting machine mounted on 7ton truck chassis" as per detailed technical specification and approved make for waste collection, management and disposal purpose as per instruction of Engineer In charge.

1

-

-

... More
Supply of "Bucket Grabber Machine Mounted on truck" as per detailed technical specification and approved make for waste collection, management and disposal purpose as per instruction of Engineer In charge.

1

-

-

... More
Plantation Works Supply of "Bucket Grabber Machine Mounted on truck" as per detailed technical specification and approved make for waste collection, management and disposal purpose as per instruction of Engineer In charge.

3000

-

-

... More
Supply and Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 meters and supplying and planting hedge plants at 30 cm apart.) all complete and as per direction of Engineer in charge.

300

-

-

... More
Supplying of good quality vermicompost and mixing with available good earth and filling the same in required layers in excavated pit all complete and as per direction of Engineer in charge.

10000

-

-

... More
Supply and planting of good quality approved trees with height as detailed below including transportation to site, well developed and grown condition all complete and as per direction of Engineer in charge.(excluding excavation, vermicompost, fertilizers,watering and irrigation systems). Avenue / Fruiting /Shading / Corno Corpus tree Type 1: 0.6m upto 1m height

150

-

-

... More
Supply and planting of good quality approved trees with height as detailed below including transportation to site, well developed and grown condition all complete and as per direction of Engineer in charge.(excluding excavation, vermicompost, fertilizers,watering and irrigation systems). Avenue / Fruiting /Shading / Corno Corpus tree Type 2 : 1 to 2m height

50

-

-

... More
Supply and planting of good quality approved trees with height as detailed below including transportation to site, well developed and grown condition all complete and as per direction of Engineer in charge.(excluding excavation, vermicompost, fertilizers,watering and irrigation systems). Avenue / Fruiting /Shading / Corno Corpus tree Type 3 : 2m and above height

50

-

-

... More
Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Hedges like Red Robin, Emerald Green Arborvitae, Alife, Dorenta, Tikoma etc

231

-

-

... More
Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Hibiscus (Flower)/ Rose

160

-

-

... More
Supply and installation of 1100liters capacity HDPE, green colour Garbage four wheeled Dust bin to dispose segregated waste and the bin should be lifted by garbage compacted truck arm.The dust bin shall be UV resistance, durable 4 wheeles, 2 break system and necessary arrangement for lifting by garbage compactor truck and fork lift. Minimum net weight of 1100liters of dust bin shall be 65 kg. and Wheels Diameter : 200mm ( Make : Sintex/Nilkamal/Approved Make)

4

-

-

... More
Supply and installation of 240liters capacity HDPE, green colour Garbage two wheeled Dust bin to dispose segregated waste and the bin should be lifted by garbage compacted truck arm.The dust bin shall be UV resistance, durable 2 wheeles, 2 break system and necessary arrangement for lifting by garbage compactor truck and fork lift. Minimum net weight of 240liters of dust bin shall be 13 kg. ( Make : Sintex/Nilkamal/Approved Make)

8

-

-

... More
Disposal of waste to Solid waste disposal site Providing and operate covered truck to carry the collected waste from Organic waste to manure treatment plant site to Solid waste disposal site as per instruction of Engineer In charge. (Make: of vehicle approved by Authority ); Minimum average distance in km per trip:120km. The rate shall be inclusive of One driver and one helper for the vehicle for operation of disposing the solid waste collected Transfer station located in various zones to Solid waste disposal site, Vehicle maintenance charges, Fuel , Consumubables, Cleaning of vehicle & Labor charges towards Loading and unloading. Payment : Quarterly Payment shall be made.

1202.12

-

-

... More
Operation and Maintenance First Year of Operation and Maintenance work : As per the completion cost of the subhead- work. The work is inclusive of replacement or repairing at the location of the following equipments during the course of first year contract maintenance period, including provision of a technician , fixtures and consumables all complete and as per direction of Engineer in charge. Note: Payment shall be made on quaterly basis. Note A. Subhead for this item shall be Plumbing work from above item no 448 to item no 523. Note B. The quoted rate of bidder shall be 5% of its total quoted amount of the subhead Plumbing work from above item no 448 to item no 523. If quoted rate is not equal to 5% of the total quoted amount of the subhead Plumbing work from item no448 to item no 523, then evaluation shall be made considering the quoted rate as equal to 5% of the total quoted amount of the subhead Plumbing work from item no 448 to item no 523 and accordingly quoted rate will be modified.

1

-

-

... More
First Year of Operation and Maintenance work : As per the completion cost of the subhead- work. The work is inclusive of replacement or repairing at the location of the following equipments during the course of first year contract maintenance period, including provision of a technician , fixtures and consumables all complete and as per direction of Engineer in charge. Note: Payment shall be made on quaterly basis. Note A. Subhead for this item shall be Electrical work from above item no 524 to item no 604. Note B. The quoted rate of bidder shall be 5% of its total quoted amount of the subhead Electrical work from above item no 524 to item no 604. If quoted rate is not equal to 5% of the total quoted amount of the subhead Electrical work from item no 524 to item no 604, then evaluation shall be made considering the quoted rate as equal to 5% of the total quoted amount of the subhead Electrical work from item no 524 to item no 604 and accordingly quoted rate will be modified.

1

-

-

... More
O & M of Refuse Compactor ,truck mounted Bucket Grabber Machine and truk mounted Sewer suction cum jetting machine. First year Operation & maintenance of Refuse Compactor , truck mounted Bucket Grabber Machine and truk mounted Sewer suction cum jetting machine. Minimum average distance in km per trip: 40km. The rate shall be inclusive of driver and helper for each vehicle for operation, Vehicle maintenance charges, Fuel , Consumables, Cleaning of vehicle & Labor charges towards Loading and unloading. The vehicles should not be missused and the work shall be carried out as per the instruction of Engineer incharge. Payment : Quarterly Payment shall be made. Refuse Compactor

12

-

-

... More
O & M of Refuse Compactor ,truck mounted Bucket Grabber Machine and truk mounted Sewer suction cum jetting machine. First year Operation & maintenance of Refuse Compactor , truck mounted Bucket Grabber Machine and truk mounted Sewer suction cum jetting machine. Minimum average distance in km per trip: 40km. The rate shall be inclusive of driver and helper for each vehicle for operation, Vehicle maintenance charges, Fuel , Consumables, Cleaning of vehicle & Labor charges towards Loading and unloading. The vehicles should not be missused and the work shall be carried out as per the instruction of Engineer incharge. Payment : Quarterly Payment shall be made. Truck mounted Bucket Grabber Machine

12

-

-

... More
O & M of Refuse Compactor ,truck mounted Bucket Grabber Machine and truk mounted Sewer suction cum jetting machine. First year Operation & maintenance of Refuse Compactor , truck mounted Bucket Grabber Machine and truk mounted Sewer suction cum jetting machine. Minimum average distance in km per trip: 40km. The rate shall be inclusive of driver and helper for each vehicle for operation, Vehicle maintenance charges, Fuel , Consumables, Cleaning of vehicle & Labor charges towards Loading and unloading. The vehicles should not be missused and the work shall be carried out as per the instruction of Engineer incharge. Payment : Quarterly Payment shall be made. Truck mounted Sewer suction cum jetting machine

12

-

-

... More
First Year of Maintenance for Tree Plantation works: The work is inclusive of replanting at the location of the damaged planted trees during the course of contract maintenance period , watering of plants , deweeding, supply and application of insecticides, pesticides and fertilizers all complete and as per direction of Engineer in charge.Note: Payment shall be made on quaterly basis. Type 1: 0.6m upto 1m height In Proposed new plantation area: Note A. The quoted rate of bidder shall be 375. If quoted rate is not equal to 375, then evaluation shall be made considering the quoted rate as equal to 375 and accordingly quoted rate will be modified.

541

-

-

... More
First Year of Maintenance for Tree Plantation works: The work is inclusive of replanting at the location of the damaged planted trees during the course of contract maintenance period , watering of plants , deweeding, supply and application of insecticides, pesticides and fertilizers all complete and as per direction of Engineer in charge.Note: Payment shall be made on quaterly basis. Type 2 : 1 to 2m height Note A. The quoted rate of bidder shall be 749. If quoted rate is not equal to 749, then evaluation shall be made considering the quoted rate as equal to 749 and accordingly quoted rate will be modified.

50

-

-

... More
First Year of Maintenance for Tree Plantation works: The work is inclusive of replanting at the location of the damaged planted trees during the course of contract maintenance period , watering of plants , deweeding, supply and application of insecticides, pesticides and fertilizers all complete and as per direction of Engineer in charge.Note: Payment shall be made on quaterly basis. Type 3 : 2m and above height In Proposed new plantation area: Note A. The quoted rate of bidder shall be 1498. If quoted rate is not equal to 1498, then evaluation shall be made considering the quoted rate as equal to 1498 and accordingly quoted rate will be modified.

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.