Nava Raipur Atal Nagar Vikas Pradhikaran Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Nava Raipur Atal Nagar Vikas Pradhikaran Tender

Works
Civil And Construction
Building Construction
Opening Date19 Sep 2024
Closing Date3 Oct 2024
Tender Amount₹ 1,06,03,60,885 
Notes
Download

Costs

Summary

“Development Of Basic Infrastructure Facilities For The Establishment Of Commercial Hub (thok Vyavsayik Bazar/ Commercial Highstreet)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of embankment / sub-grade with Material Obtained from Borrow Pits (Construction of embankment with approved material/selected soil having C.B.R. (as specified in the contract and as per the construction drawings) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2) as specified by in the drawigns and Engineer in charge.

151107

33696861

223

... More
Construction of sub-grade with Material Obtained from Borrow Pits/Borrow Area (Construction of sub-grade with approved material/selected soil having C.B.R.8 (unless specified otherwise in the contract) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)

151107

37776750

250

... More
Construction of Median and Island with Soil Taken from Roadway Cutting (Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other structures, spread, graded and compacted as per clause-408.)

41547

7270725

175

... More
Granular Sub-base as per Table:- 400-1 Construction of Granular sub-base by providing close graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 . Plant mix method (with Mechanically crushed stone only) for grading-III Material

59873.78

85200388

1423

... More
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)

65148

93422232

1434

... More
Prime Coat ( Providing and applying primer coat with oil based bitumen emulsoion (SS-I, grade confirming to IS:8887) on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per cluse 502. (i) on WBM/WMM surface @0.85 Kg/sqm.

225346

14422144

64

... More
Tack Coat Providing and applying tack coat with bitumen emulsion(RS-1, grade confirming to IS:8887) using emulsion pressuredistributor on the prepared bituminous/granular surface cleaned withmechanical broom and as per clause 503. (i)Bituminous Surface@0.25kg/Sqm

225347

3380205

15

... More
Dense Bituminous Macadam (Providing and laying dense bituminous macdam with minimum 40-60 TPH capacity HMP using crushed aggregates of specified grading, premixed with bituminous binder @4.0 to 4.5% by weigth of toal mix of mix and filler, transporting the hot mix to work site laying with hydrostatic paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause N0.505 complete in all aspects.) A. with sensor paver finishere for Grading -II(26.5mm nominal size bitumen content 4.50%)

11168

90996864

8148

... More
Bituminous Concrete ( providing and laying bituminous concrete with minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.0 to 6.0% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment,rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification caluse No.507 complete in all repsects) A. with sensor paver finishere for Grading -II(13.2mm nominal size) with bitumen 6.0%

8841

89223372

10092

... More
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M20 grade PCC on M10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408).

28780

5957460

207

... More
Cast in Situ Cement Concrete M20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409)

30150

11547450

383

... More
Providing & Laying precast interlocking concrete block of minimum compressive strength of 300kg/sq.cm and approved size, shape/ pattern over coarse sand bed of thickness upto 40 mm and joints thick filled with fine sand including leveling with surface vibrator, temping and sweeping etc.complete as per IRC-SP-63-2004.A)60mm thick Plain precast interlock concrete block (C) 80mm thick Polymer coated coloured precast interlock concrete blocks

41977

30727164

732

... More
For edging Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).

68

241536

3552

... More
Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement : 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement : 3 coarse sand) but excluding reinforcement.

5561

2608109

469

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-1997. The finished surface to be level, uniform and free from streaks and holes.)

6869

4856383

707

... More
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminum sheeting, 1.5 mm thick supported on a mild steel frame of size 40 x 40 x 5 mm and mild steel angle iron post 75 mm x75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing).

-

-

-

... More
60 cm x 45 cm rectangular

20

86540

4327

... More
60 cm equilateral triangle

20

62560

3128

... More
60 cm Circular

20

89200

4460

... More
90 cm high octagon

20

171040

8552

... More
Painting on Concrete Surfaces Two coats on new surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)

20113

1247006

62

... More
Planting of Trees and their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia. holes, 1 m. deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year)

9862

7396500

750

... More
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . )

-

-

-

... More
450 mm Dia

120

212280

1769

... More
600 mm Dia

115

282785

2459

... More
1000 mm Dia

100

537000

5370

... More
Providing 1 st class bedding below pipes with graded sand or other granular materials passing through 5.6 mm sieve as per clause 2904.

3979

3020061

759

... More
Providing and laying Pitching Stone/Boulder on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per clause 2504.

26

62738

2413

... More
Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand:

-

-

-

... More
Furn like Arica, China etc (3 year old)

5000

625000

125

... More
Hibiscus (Flower)/ Rose

5000

132500

26.5

... More
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff all lead and lift, including dressing and leveling of pits.

-

-

-

... More
In all types of soil

44626

8255810

185

... More
Extra for every additional lift of 1.5 m or part thereof., All types of soils

51.02

1353

26.5

... More
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.

187470

12185550

65

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.

-

-

-

... More
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).

3156

9373320

2970

... More
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:

-

-

-

... More
Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.

123207

17125773

139

... More
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work.

-

-

-

... More
M-20 Grade,

10509

44463579

4231

... More
M-25 Grade,

50

214900

4298

... More
M-40 Grade,

5343

23990070

4490

... More
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to all level

-

-

-

... More
Thermo-Mechanically treated Bars FE 500D

1700409.73

152441733

89.65

... More
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.

-

-

-

... More
110 mm dia. 4 kg/sq.cm

6051

1615617

267

... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)

6939

1013094

146

... More
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification including trimming of slopes to proper profile and preparation of bed and as per clause 2504.

51

106029

2079

... More
Providing and laying Pitching Stone/Boulder on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per clause 2504.

9

21717

2413

... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications.

-

-

-

... More
With Batching Plant, Transit Mixer and Concrete Pump

-

-

-

... More
RCC Grade M30

707

4283006

6058

... More
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags).

-

-

-

... More
Height upto 5m

-

-

-

... More
With Batching Plant, Transit Mixer and Concrete Pump

-

-

-

... More
R.C.C. Grade M-30

632

4070080

6440

... More
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700 (Newly laid concrete shall be covered by gunny bags).

-

-

-

... More
RCC Grade M 30

-

-

-

... More
For Solid Slab Super Structure

-

-

-

... More
Using Batching Plant, Transit Mixer and Concrete Pump

-

-

-

... More
Height upto 5m

549

3860568

7032

... More
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC pipe, extending through the full width of the structure with slope of 1 V: 20 H towards drawing face. Complete as per drawing and Technical specifications section 2706 and 2200.

200

64200

321

... More
Providing and laying M-30 grade Reinforced cementconcrete approach slab including reinforcement and formwork complete as per drawing and Technical specification and as per relevant sections 1500, 1600, 1700 and 2704

114

1079238

9467

... More
Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications as per relevant clauses of section 1500, 1600, 1700 and 2703 (vide drawing No. SD/202, SD/304)

105

196770

1874

... More
Painting on concrete surface of R.C.C. Railing (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litrefor 2 Sq.m. )

126

19026

151

... More
Earth work in excavation for pipe trench in ordinary soil are as including dressing, watering and ramming and disposal of excavated earth all lead and lift, disposal earth to be leveled, neatly dressed.

-

-

-

... More
Upto 1.5 m deep

73654

14804454

201

... More
1.5m and upto3.0m deep

33545

8990060

268

... More
Earth work in Excavation for pipe trench in Hard Soil areas including dressing, watering and ramming and disposal of Excavated earth all lead and lift , disposal earth to be leveled, neatly dressed.

-

-

-

... More
Upto 1.5 m deep

5044

1341704

266

... More
1.5m and upto 3.0m deep

3447

1330542

386

... More
Extra for every additional lift of 1.5m or part there of

-

-

-

... More
All Kind of soil

50435

3379145

67

... More
Ordinary Soft & Hard Rock

33944

4073280

120

... More
Providing, laying and jointing followings ISI marked O-PVC (Oriented uplasticized polyvinyl chloride) ring fit type pipe having orientation class 500 (IS 16647) with integral homogeneous spigot having elastomeric seeling ring made of EPDM rubber (one per pipe) including testing of joint, cost of jointing materials etc. complete in all respect. Presure Rating as

-

-

-

... More
150 mm diameter

700

700700

1001

... More
200mm diameter

6580

10120040

1538

... More
315mm diameter

6580

19555760

2972

... More
Providing, laying and jointing socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (classK-7) Conforming to IS 8329/2000 with suitable Rubber Gasket (Pushon) joints as per IS:5382/85 including testing of joint (laying Conforming to IS 12288 : 1987)

-

-

-

... More
150mm diameter

700

1262800

1804

... More
200mm diameter

9605

22840690

2378

... More
300mm diameter

3555

13416570

3774

... More
Providing & Supplying D.I. Specials & Fittings For all types of specials, bends, tees.. etc.

-

-

-

... More
80 to 300 mm dia

5000

350000

70

... More
Providing and laying in position including testing following sizes of flanged cast iron standard specials class medium or heavy which does not appear in above items of the schedule.

-

-

-

... More
80mm to 300mm dia (Heavy Class)

5200

327600

63

... More
Supply & Filling moorum/river sand for pipe bedding or over the pipe (including supply)

1588

1372032

864

... More
Providing & fixing of following Ductile iron double flanged sluice valves as per I.S.:14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete.

-

-

-

... More
Sluice Valve/Scour valve

-

-

-

... More
80 mm dia. PN-1.6

6

51732

8622

... More
100 mm dia. PN-1.6

2

23170

11585

... More
150 mm dia. PN-1.6

4

60800

15200

... More
200 mm dia. PN-1.6

15

417750

27850

... More
300 mm dia. PN-1.6

12

824868

68739

... More
Providing & fixing following ductile iron single chamber triple function temper proof air valves, small orifice with screwed end as per IS : 14845-2000 including jointing & testing with cost of jointing material and rubber insertion all complete as per IS :13095-1991

-

-

-

... More
80 mm dia PN-1.6

6

51252

8542

... More
100 mm dia PN-1.6

2

22826

11413

... More
Providing, fixing and testing following double flanged cast iron(horizontal cast) pipe per IS :7181of One Meter length.

-

-

-

... More
80mm diameter

6

10206

1701

... More
100mm diameter

2

4794

2397

... More
Providing, laying, jointing, testing and commissioning of D.I Dismantling joint with M.S. Nut stud & washers coated for rust prevention & internal rubber rings etc. complete assembly set as per type design inclusive of all taxes & duties, insurance, loading/ unloading & stacking FOR at site all complete as per technical Specifications and as per direction of Engineer.

-

-

-

... More
80mm diameter

6

15204

2534

... More
100mm diameter

2

5818

2909

... More
150mm diameter

4

19708

4927

... More
200mm diameter

12

83052

6921

... More
300mm diameter

12

146832

12236

... More
Steel work in welded built-up section/ framed work, including cutting hoisting, fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.

-

-

-

... More
In gratings, frames, guard bar, ladder ,railings, brackets, gates and similar works

1600

108800

68

... More
Making connection of drain or sewer line with existing service lines manhole including breaking into and making good the walls, floors etc. with cement concrete grade M-15 (Nominal Mix) with stone aggregate 20mm nominal size plastered with Cement Mortar 1:3 (1Cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels etc. complete.

-

-

-

... More
For 250 to 300 mm dia pipes

1

348

348

... More
For 350 to 450 mm dia pipes

1

467

467

... More
Supplying and laying following sizes one number XLPE, steel armoured, aluminium conductor power cable of 11 KV grade in existing RCC/HUME/STONEWARE/METAL/masonry open duct as required. 3C X 240 sqmm

4600

8487000

1845

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as required : 240 sqmm

12

51984

4332

... More
Supplying and making STRAIGHT THROUGH cable jointing with heat shrinkable cable jointing kit including ferrule and other jointing materials, for following size of 3 core, PILC aluminum conductor cable of 11 KV grade as required : 240 sqmm

8

84384

10548

... More
Earthing with G.I. earth pipe 3.0 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as quired.

750

2432250

3243

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as required

3

18627

6209

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.

10

5130

513

... More
Supply and laying of 25x6 mm GI strip along with cable and making connections firmly with accessories hard wardres etc required for completenences and as per attached specification direction of engineer ,CGPWD standards and electrical inspectorate standardsand connection

4000

376000

94

... More
Supplying and erecting chain link mesh fencing for electric sub-station switch yard of 2.5 m approx. height from ground level using angle iron size 50 X 50 X 6 mm erected in C.C.foundation 15 X 15 X 40 cm deep at every 2 metre fitted with flat iron support of size 25 X 6 mm on top, bottom and mid way and chain link mesh 50 x 50 mm aparture and 4 mm dia G.I. hard wire securing and screwing with 2mm dia G.I. wire, G.I. staples, G.I.U-nails or steel pins to the angle iron at every distance of 30 cms, by iron studs complete duly painted with one coats of red oxide and two coats of approved colour paint as per CSPDCL standards and direction of EIC.

120

61320

511

... More
Supplying and erecting MS gate of approx. size 3.0 m (W) x 2.0 m (H) in two laps for electric sub-station switch yard fencing frame made of angle iron size 50 X 50 X 6 mm on top bottom and sides fitted with flat iron support of size 25 X 6 mm on mid way horizontaly and square bar of size 8 mm at every 100mm vertically including 3 sets of heavy duty MS hinges and aldrop complete duly painted with one coats of red oxide and two coats of approved colour paint as per CSPDCL standards and direction of EIC.

12

12456

1038

... More
Supplying and spreading hard stone aggregate 25 mm size in out door switch as per direction of engineer -in-charge

6

5436

906

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted/ welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

5

1545

309

... More
Providing brick masonry work in cement mortat 1:4 (1 cement : 4 coarse sand) with well burnt clay modular bricks having compressive strength not less than 25kg/sqmm at all levels including scaffolding curing etc complete.

8

30224

3778

... More
Plastering 15 mm thick on brick work/ CC surface with cement mortar 1:4 (1 cement : 4 fine sand) at all levels.

20

2140

107

... More
Supply Installation, testing & commissioning of 11/ 0.433 KV, 100 KVA distribution transformer with off load tap changer, AL wound, oil cooled suitable for outdoor use with required fittings, accessories,both side cable terminal box, hardwares etc. as required for completeness as per attached specification/drawing, CSPDCL standards and direction of EIC.

1

152907

152906.21

... More
Supply, running and terminating of GI materials as earth continuity conductor to earth all the metallic parts/ neutral of transformer/ lightning arrestors, control room equipments to earth electrodes with accessories, hardwares etc. as required for completeness, as per attached specification/ drawings, CSPDCL standards and direction of EIC.

-

-

-

... More
25mm x 6mm strips

300

29850

99.5

... More
6 SWG wires

300

11400

38

... More
Designing and providing suitable RCC foundation for 7 metre to 12 metre high GI octagonal pole including steel reinforcement (minimum 90kg per cum), form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required.

455

2374645

5219

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as per specification.

150

209550

1397

... More
Supplying and laying following sizes one number XLPE insulated, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL pipe as required.

-

-

-

... More
3.5x120 sq mm

300

114300

381

... More
3.5 x 50 sq. mm.

500

86500

173

... More
3.5 x 25 sq. mm.

13000

1521000

117

... More
4 x16 sq. mm.

9000

927000

103

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as required.

-

-

-

... More
3.5x120 sq mm

10

3180

318

... More
3.5 x 50 sq. mm.

28

4704

168

... More
3.5 x 25 sq. mm.

60

6240

104

... More
4 x 16 sq. mm.

84

8484

101

... More
Supplying and laying following size RCC Hume pipe class NP-2 (in standard length of 2 metre) with collar in ground below road, path etc at a depth not less than 50 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as required.

-

-

-

... More
300 mm dia.

1364

1002540

735

... More
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core/ lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as required.

-

-

-

... More
3.5 x 120 sq. mm.

50

1500

30

... More
4 x 16 sq. mm.

3200

60800

19

... More
3.5 x 25 sq. mm.

2400

52800

22

... More
3.5 x 50 sq. mm.

200

4200

21

... More
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 4mm thick anchor plate, 4 nos 24mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 10 metre high, dia 175mm at bottom and 90mm at top, base plate size 275x275x16mm, foundation bolts 750mm long

440

8334480

18942

... More
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 4mm thick anchor plate, 4 nos 24mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 9 metre high, dia 155mm at bottom and 90mm at top, base plate size 260x260x16mm, foundation bolts 750mm long

265

3703110

13974

... More
Erection of GI octogonal/ tubular pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as required 10 metre high

440

460680

1047

... More
Erection of GI octogonal/ tubular pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as required 9 metre high

265

261025

985

... More
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as required.

-

-

-

... More
single Over Hang 1.50 metre Long

440

542520

1233

... More
single Over Hang 1.00 metre Long

265

280105

1057

... More
single Over Hang 0.75 metre Long

440

465080

1057

... More
Supplying, Installation, testing and commissioning for the following RF Based analogue (0-10v) dimmable LED Street Light fixture with IP66 protected Die-Cast Aluminum housing and Heat resistive Toughened Glass. LED shall having LM80 complied as per L70 standard LEDs minimum tested for 10,000 burning hours with 5700-6000K CCT with minimum life cycle 50000 hrs burning hours at 50”C. Luminaire shall have RF node for communication thru CCMS. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage Constant Current Constant Voltage with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60V DC. Driver Power factor shall be 0.95 and above and THD shall be less than 10%.LED chip efficacy ratio ˃120 lumens/watt

-

-

-

... More
Not More than 135 Watt

440

5999400

13635

... More
Not More than 90 Watt

265

2234745

8433

... More
Not More than 45 Watt

440

2347400

5335

... More
Supply, drawing and terminating either ends 3 core FR PVC insulated 1.5 sqmm copper cable inside the pole from JB to fixtures with accessories, hardwares etc as required for completeness and as per attached specification, direction of engineer, CGPWD standards and Electrical inspectorate standards.

11500

425500

37

... More
Supplying and laying double wall HDPE pipe having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm including excavation, dismantling of road if required and refilling the trench etc. as required. 63 mm dia

600

110400

184

... More
90 mm dia

600

121800

203

... More
Supply, installation, testing & commissioning of 33 KV(E), XLPE Al Cable round wire armoured of 3C X 300 sqmm in readymade trenches with clamping materials, ferrules, tags, accessories, hardwares, earthing etc as required for completeness, as per attached specification/ drawing, CSPDCL standards and direction of EIC

100

281500

2815

... More
Supply, installation, testing & commissioning of 11 KV(E), XLPE Al Cable round wire armoured of 3C X 300 sqmm in readymade trenches with clamping materials, ferrules, tags, accessories, hardwares, earthing etc as required for completeness, as per attached specification/ drawing, CSPDCL standards and direction of EIC

100

212700

2127

... More
Supply, installation, glanding, terminating, testing & commissioning of 1.1kV grade XLPE Al cable in readymade trenches with clamping materials, ferrules, tags, accessories, hardwares, earthing etc as required for completeness, as per attached specification/ drawing, CSPDCL standards and direction of EIC

-

-

-

... More
3.5 core 50sqmm

200

34600

173

... More
3.5 core 70sqmm

350

86800

248

... More
3.5 core 150sqmm

100

48400

484

... More
Supply of all materials, installation, testing and commissioning of GI pipe electrode as per IS: 3043 comprising of 40mm dia, 2.9mm thick, 3m long class A GI pipe with flange, 16nos. 12mm dia through holes buried in a pit. The scope shall cover excavation in all kinds of soil and rock, filling the pit with equal proportion of salt and charcoal in layers of 300mm depth, 150mm wide alround the pipe from bottom upto a depth of 300mm below the masonary chamber, refilling by excavated soil free from rock and shark edges; provision of watering arrangement with GI funnel and wire mesh be enclosed in a brick masonary chamber of 400mm x 400mm x 400mm with removable RCC cover on top. The connection from the flanges of the pipe shall be established by 50mm x 6mm GI strip using 12mm dia GI hardwares. The work shall be carried out with accessories, hardware etc as required for completeness, as per attached specification/ drawing, CSPDCL standards and direction of EIC.

30

97290

3243

... More
Supplying and making INDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as per specification:

-

-

-

... More
300 sq. mm

6

26244

4374

... More
Supplying and making INDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, XLPE aluminum conductor cable of 33 KV grade as per specification. :

-

-

-

... More
300 sq. mm

10

95510

9551

... More
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and depth above 300 mm and upto 450mm made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ameters ets as per specifications including powder coating painting with busbars, switchgears and angle frame other accessories etc complete as required as following:. 4 strip al bus bar of size 50 x 5mm and 300amps (1no.) analog type 0-500 amp ammeter of size 100x100 (NS) (1no.) analog type 0-500 volt voltmeter of size 100x100 (NS) (1no.) selector switch fro voltmeter (1no.) selector switch fro ammeter (1no.) 230 volt LED type indicating lamp (3nos.) 4 pole MCCB, 250A, 35KA (for Transformer Panel) (1no.) 3 Nos 4 pole, 63A MCCB, 35kA as outgoing feeders ,3 Nos 125 A MCCB ,35 kA

1

125000

125000

... More
Supply, Installation, Testing & Commissioning of indoor floor mounted 33KV switchboard comprising of 2 vertical panels with horizontal top bus bars of Al rated for 800 A VCBs and LBS, in draw out executions. The VCB shall be rated for 36KV, 1600A, 26kA. The panels shall be complete with all accessories, hardwares etc. as required for completeness, as per attached specification/ drawing, CSPDCL standards and direction of EIC. and as detailed below: Shall be compatible to existing system.

1

4012867

4012866.76

... More
·   1 no. Panel for controlling outgoing feeders with VCB, CTs, PTs, digital Ammeter/ voltmeter/ static Energy meter, O/C and E/F relay etc.

-

-

-

... More
·     1no. Panel for controlling 5MVA power transformer with VCB, digital meters, transformer protection relays, auxiliary relays etc.

-

-

-

... More
Supply, Installation, Testing & Commissioning of indoor floor mounted 11KV switchboard comprising of 4 vertical panels with horizontal top bus bars of Al rated for 800 amp VCBs/ LBS, in draw out executions. The VCB shall be rated for 12KV,18.4kA. The panels shall be complete with all accessories, hard wares etc. as required for completeness, as per attached specification/ drawing, CSPDCL standards and direction of EIC. and as detailed below and shall be compatible to existing system

1

5513243

5513243

... More
· 1no. Panel for controlling incomer with VCB of 800 A ratings, CTs, PTs, digital Ammeter/ voltmeter/ Energy meter, O/C and E/F relay etc.

-

-

-

... More
·2 nos. Panel for controlling outgoing feeders with VCB of 400 A rating, CTs, digital meter, Static Energy meters, O/C and E/F relay, auxiliary relays etc.

-

-

-

... More
· 1nos. Panel for controlling capacitor bank with VCB of 400 A, CTs, digital meter, capacitor protection relays etc.

-

-

-

... More
Inbuilt of drain cover slab in providing perforated holes using PVC pipe 50 mm dia. including cost of allmaterials and labour involved with all leads and lifts etc. as per drawing and direction of Engineer in Charge.

7249

272925

37.65

... More
Structural steel hot dip galvinized MS angle welded over a base plate including cutting, welding ,hoisting and fixing in position with 3 nos. of 12mm diameter fastnerrs etc. complete as per drawings and direction of Engineer complete etc.

57708

4674348

81

... More
Provision for Ductile iron/M.S pipe inter connection of old to new pipe line with excavation of trench as per requirement of any diameter & type of pipe line in muddy area i/c dewetering the trench laying & jointing of pipe and specials, back filling the trench i/c testing of joints cost of labour & specials such as D-Joints couplers, flanged sockets,Tee solvent cement including all lead and lift upto 1.5m depth and pipe dia. upto 300mm, complete job work as per approved specification and as directed by Engineer in charge.

2

9871

4935.4

... More
Providing, laying, Jointing & field testing of DWC HDPE Pipes (with external annular corrugation and smooth internal walls) duly tested Conforming to IS 16098 (PART-II): 2013 having stiffness class of SN 8 with ring stiffness not less than 8.00KN/SQM. and impact resistance TIR valve not more than 10% including necessary jointing materials for non-pressure underground sewerage, drainage & cross drainage application. Inclusive of all taxes related to central, state and municipal, inclusive of excise duty, inspection charges, transportation charges, transit insurance, loading/unloading and stacking at site/store etc. and as per Technical Specifications and as per direction of Engineer.This is also inclusive of Jointing material i.e Pipe with online/offline coupler and elastomeric sealing ring. All the joints shall be confirmed water tight as per standards.

-

-

-

... More
300/345 mm dia

10305

12036240

1168

... More
400/480 mm dia.

3555

8229825

2315

... More
Providing, fixing, installation, testing and commissioning of Precast RCC M-40 grade Rectangular chamber with internal size 0.9X0.8m depth upto 1.0m. wall thick 150mm, bottom slab thick=150mm, FRP circular cover internal opening size 600mm dia. (Designed for 20tone loading capacity (heavy duty) etc.). 100mm thick bottom PCC 1:3:6, fixing of FRP frame and cover using M-20 grade concrete. with CM1:1 around pipe entering and leaving the chamber, providing and fixing of safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia. steel bar of approved make at every 0.30m height, including double jali steel reinforcement 10mm dia. bar vertical and horizontal both the direction 150mm c/c as per drawing, hydro testing of chamber, loading, unloading, conveyance & cost of labour, earth work in excavation, backfilling, dewatering etc. complete as per direction of Engineer-in-Charge.

25

784075

31363

... More
Providing, fixing, installation, testing and commissioning of Precast RCC M-40 grade Rectangular chambers with internal size 1.2X0.9m depth upto 1.3m. wall thick 150mm, bottom slab thick=150mm, FRP circular cover internal opening size 600mm dia. (Designed for 20tone loading capacity (heavy duty) etc.). 100mm thick bottom PCC 1:3:6, fixing of FRP frame and cover using M-20 grade concrete. with CM1:1 around pipe entering and leaving the chamber, providing and fixing of safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia. steel bar of approved make at every 0.30m height, including double jali steel reinforcement 10mm dia. bar vertical and horizontal both the direction 150mm c/c as per drawing, hydro testing of chamber, loading, unloading, conveyance & cost of labour, earth work in excavation, backfilling, dewatering etc. complete as per direction of Engineer-in-Charge.

70

2662940

38042

... More
Providing, fixing, installation, testing and commissioning of Precast RCC M-40 grade Rectangular chambers with internal size 1.2X0.9m depth upto 1.6m. wall thick 150mm, bottom slab thick=150mm, FRP circular cover internal opening size 600mm dia. (Designed for 20tone loading capacity (heavy duty) etc.). 100mm thick bottom PCC 1:3:6, fixing of FRP frame and cover using M-20 grade concrete. with CM1:1 around pipe entering and leaving the chamber, providing and fixing of safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia. steel bar of approved make at every 0.30m height, including double jali steel reinforcement 10mm dia. bar vertical and horizontal both the direction 150mm c/c as per drawing, hydro testing of chamber, loading, unloading, conveyance & cost of labour, earth work in excavation, backfilling, dewatering etc. complete as per direction of Engineer-in-Charge.

70

2856700

40810

... More
Providing, fixing, installation, testing and commissioning of Precast RCC M-40 grade Rectangular chambers with internal size 1.2X0.9 m depth upto 1.9m.wall thick 150mm, bottom slab thick=150mm, FRP circular cover internal opening size 600mm dia. (Designed for 20tone loading capacity (heavy duty) etc.). 100mm thick bottom PCC 1:3:6, fixing of FRP frame and cover using M-20 grade concrete. with CM1:1 around pipe entering and leaving the chamber, providing and fixing of safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia. steel bar of approved make at every 0.30m height, including double jali steel reinforcement 10mm dia. bar vertical and horizontal both the direction 150mm c/c as per drawing, hydro testing of chamber, loading, unloading, conveyance & cost of labour, earth work in excavation, backfilling, dewatering etc. complete as per direction of Engineer-in-Charge.

100

4371700

43717

... More
Providing, fixing, installation, testing and commissioning of Precast RCC M-40 grade Rectangular chambers with internal size 1.2X0.9 m depth upto 2.2m. wall thick 150mm, bottom slab thick=150mm, FRP circular cover internal opening size 600mm dia. (Designed for 20tone loading capacity (heavy duty) etc.). 100mm thick bottom PCC 1:3:6, fixing of FRP frame and cover using M-20 grade concrete. with CM1:1 around pipe entering and leaving the chamber, providing and fixing of safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia. steel bar of approved make at every 0.30m height, including double jali steel reinforcement 10mm dia. bar vertical and horizontal both the direction 150mm c/c as per drawing, hydro testing of chamber, loading, unloading, conveyance & cost of labour, earth work in excavation, backfilling, dewatering etc. complete as per direction of Engineer-in-Charge.

60

2789040

46484

... More
Providing, fixing, installation, testing and commissioning of Precast RCC M-40 grade Rectangular chambers with internal size 1.2X0.9 m depth upto 2.5m. wall thick 150mm, bottom slab thick=150mm, FRP circular cover internal opening size 600mm dia. (Designed for 20tone loading capacity (heavy duty) etc.). 100mm thick bottom PCC 1:3:6, fixing of FRP frame and cover using M-20 grade concrete. with CM1:1 around pipe entering and leaving the chamber, providing and fixing of safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia. steel bar of approved make at every 0.30m height, including double jali steel reinforcement 10mm dia. bar vertical and horizontal both the direction 150mm c/c as per drawing, hydro testing of chamber, loading, unloading, conveyance & cost of labour, earth work in excavation, backfilling, dewatering etc. complete as per direction of Engineer-in-Charge.

75

3704925

49399

... More
Providing, fixing, installation, testing and commissioning of Precast RCC M-40 grade Rectangular chambers with internal size 1.3X1.0m depth upto 2.8m. wall thick 150mm, bottom slab thick=150mm, FRP circular cover internal opening size 600mm dia. (Designed for 20tone loading capacity (heavy duty) etc.). 100mm thick bottom PCC 1:3:6, fixing of FRP frame and cover using M-20 grade concrete. with CM1:1 around pipe entering and leaving the chamber, providing and fixing of safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia. steel bar of approved make at every 0.30m height, including double jali steel reinforcement 10mm dia. bar vertical and horizontal both the direction 150mm c/c as per drawing, hydro testing of chamber, loading, unloading, conveyance & cost of labour, earth work in excavation, backfilling, dewatering etc. complete as per direction of Engineer-in-Charge.

50

2756700

55134

... More
Construction of RCC valve chamber internal size 1.2m x 1.0m x 1.3m, 100mm thick PCC- M10 and RCC M20 grade 150mm thick wall, M-35 grade precast cover 200mm thick slab, on top for protection of valve coming under traffic & extended MS valve operating spindle rod as reqd etc. Including steel reinforcementon 10mm dia. 150mm c/c bothways top and bottom in precast cover, dobel reinforcement in wall and as per drawing, shuttering, labour charges, providing and fixing of safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia. steel bar of approved make at every 0.30m height etc as per drawing and as per direction of Engineer complete etc.

31

974392

31432

... More
Providing, laying, Jointing & field testing of DWC HDPE Pipes (with external annular corrugation and smooth internal walls) duly tested Conforming to IS 16098 (PART-II): 2013 having stiffness class of SN 8 with ring stiffness not less than 8.00KN/SQM. and impact resistance TIR valve not more than 10% including necessary jointing materials for non-pressure underground sewerage, drainage & cross drainage application. Inclusive of all taxes related to central, state and municipal, inclusive of excise duty, inspection charges, transportation charges, transit insurance, loading/unloading and stacking at site/store etc. and as per Technical Specifications and as per direction of Engineer.This is also inclusive of Jointing material i.e Pipe with online/offline coupler and elastomeric sealing ring. All the joints shall be confirmed water tight as per standards.

-

-

-

... More
170/200 mm dia.

682

279620

410

... More
Horizontal drilling: Horizontal directional drilling along roads for laying XLPE HT/ LT, UG cable, for communication cable along with suitable HDPE Duct at various locations as pointed out by departmental officers, includes Survey of site information collection regarding underground utilities, sensing of utilities by sensing equipment, pit making, pilot drilling, pre-reaming pulling HDPE duct of suitable size in single roll, pulling HT/ LT UG cable through installed , providing barricades and necessary signal lights, closing of pits with excavated earth including cost of HDPE pipe, consolidating pit are, including road restoration/supervision departments, cost of all materials, labour, conveyance, hire charges etc. complete preparation of pit by excavated soil/ hard morum & refilling compacting surface as it is position / horizontal drilling across road for cable laying propose with disturbing present installation as per instruction, Guide line Detail technical specifications as per direction of Engineer in charge inner dia. 200mm and outer dia. 240mm

60

238980

3983

... More
Supply, Installation, Testing & Commissioning of floor mounted SF6, motorized type RMU (extendible type) comprising of 4 nos. 12 kV, 630 A LBS for loop in and loop out to form ring main system complete with accessories, hard wares, inbuilt PT etc. as required for completeness as per attached specification/ drawing, CSPDCL standards and direction of EIC.

2

2390030

1195015

... More
Supply, Installation, Testing & Commissioning of floor mounted SF6, motorized type RMU (extendible type) comprising of 3 nos. 12 kV, 630 A LBS for loop in and loop out to form ring main system & 1 VCB for transformer control complete with accessories, hard wares, inbuilt PT etc. as required for completeness as per attached specification/ drawing, CSPDCL standards and direction of EIC.

2

2390030

1195015

... More
Supply, running and terminating of GI materials as earth continuity conductor to earth all the metallic parts/ neutral of transformer/ lightning arrestors, control room equipments to earth electrodes with accessories, hardwares etc. as required for completeness as per attached specification/ drawing, CSPDCL standards and direction of EIC.

-

-

-

... More
vi) 50mm x 6mm strips

200

38128

190.64

... More
vii) 8 SWG wires

200

2152

10.76

... More
viii)10 SWG wires

216

1929

8.93

... More
Design, Fabrication, Supply, Erection, Testing and commisioning of Powder coated, Weather Proof Double door type Feeder pillar fabricated out of 14 guage CRCA sheet steel in cubical, free standing, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Feeder pillar shall be treated with all anti-corrosive process before painting as per specification. Feeder Pillar shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels with RJ45 Port .Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated)

2

500000

250000

... More
INCOMER

-

-

-

... More
1No. 4 Pole 100A TPN MCCB (35 KA)

-

-

-

... More
1No. 100A FP Contactor, AOM switch & Timers for 24 Hrs. setting

-

-

-

... More
Metering & Indication

-

-

-

... More
1 set of phase indicating lamps

-

-

-

... More
BUS-BAR

-

-

-

... More
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves

-

-

-

... More
OUTGOINGS

-

-

-

... More
24 Nos. 32A SP MCB

-

-

-

... More
GPRS MODULE FOR AUTOMATION

-

-

-

... More
Supplying and laying double wall HDPE pipe having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm including excavation, dismantling of road if required and refilling the trench etc. as required. 40 mm dia

23000

2507000

109

... More
Supply, installation, glanding, terminating, testing & commissioning of 1.1 kV grade armoured PVC-A-PVC copper control cable in readymade trench with clamping materials, ferrules, tags, accessories, hardwares, earthing etc as required for completeness, as per attached specification/ drawing, CSPDCL standards and direction of EIC.

-

-

-

... More
2 core 2.5 sqmm

200

14040

70.2

... More
4 core 2.5 sqmm

100

11928

119.28

... More
8 core 2.5 sqmm

100

21561

215.61

... More
Supply Installation, testing & commissioning of 33/ 11 KV, 5MVA power transformer with off load tap changer, copper wound, oil cooled, suitable for outdoor use with fitting accessories, hardwares etc. as required for completeness as per attached specification/ drawing, CSPDCL standards and direction of EIC.

1

5484602

5484602

... More
Supply Installation, testing & commissioning of 12KVA shunt capacitor bank of 1200 KVAR size, complete with mounting stand, discharge resistors, RVTs, CT digital meters, protective relays, APFC relays interconnecting bus bars, accessories, hardwares etc. as required for completeness, as per attached specification/ drawing, CSPDCL standards and direction of EIC.

1

1486017

1486017

... More
i)     Supply, installation, testing & commissioning of M.S.angel channel patti nuts, bolts and clamps tie rail and sundries material to complete job, welding & fabrication per instruction, Guide line Detail technical specifications. (Drg & Design to be approved by EIC)

1

110462

110462

... More
ii)    Supply, installation, testing & commissioning of all the type of clamps ,connector , lugs, tape, etc material as per Detail's specifications (Drg & Design to be approved by EIC)

1

7952

7952

... More
iii)   Supply Installation, testing & commissioning of copper plate earthing size 600x600x3.15 mm including complete with refilling of pit by chemical, coal, salt, black cotton soil riser up to equipment packing of charcoal powder and salt as per IS 3043 specification including excavation in all type of soil providing of chamber, cover, watering pipe. (Drg & Design to be approved by EIC)

10

62090

6209

... More
iv)  Supply Installation, testing & commissioning of spike earthing, 2 mtr long 25mm dia G.I. rod complete with refilling of pit by chemical, coal, salt, black cotton soil riser up to equipment as per drawing ,design of Sub-Station, instruction, Guide line (Drg & Design to be approved by EIC)

18

18522

1029

... More
v)   Supply, installation, testing & commissioning of earthing with 50x6 mm Cu Strip S/S & connection complete with earth electrode /plate in yard, ground, trench, control room with nut bolt spring & plain wisher as per Detail's instruction, Guide line (Drg & Design to be approved by EIC).

450

343350

763

... More
Supply of all required materials, fabrication, installation and panting of MS structural of various sizes for equipment supports with accessories, hardwares etc. as required for completeness, as per attached specification/ drawings, CSPDCL standards and direction of EIC.

5

347900

69580

... More
Fire fighting :Providing & fixing, 2no fire fighting stand ( with 4 no 16 lts buckets with sand) & sign board including letter writing of, equipment & other in transformer yard as per IS standard and Safety provisions etc. complete, as per direction of Engineer in charge.

1

45668

45667.2

... More
Safety Equipments :Supply & providing of safety helmet -4 no, discharge rod -2 no, HT hand glubs-2 no, rubber mate in front of each panel, safety chart, notice board, single line as per Detail's instruction ,Guide line etc. complete as per direction of Engineer in Charge.

1

73613

73612.8

... More
Electric Insulating Rubber Mats: Providing, lowering, laying, aligning, fixing in position and jointing at all levels insulating mats safeguard life of Electricians & other Technicians, in case of any accidental current leakage while working on AC or DC installations as per IS: 15652 (2006) testing and commissioning and complete in all respect as per technical specification and as per direction of Engineer NRANVP

-

-

-

... More
Thickness=3mm, width=1000mm, length=10m colour coding=Black or blue , Antiskid Rough Surface=Dimond plate, matting class=C, Max use voltage ac (rms ) 33 kV & Dc (rms ) 240 V , Di electric strength AC (rms ) 65 kV, Proof voltage AC (rms ) 36 kV

22

42130

1915

... More
Transformer Foundation: Planning, Designing and construction of RCC-M20 foundation for transformer mounting plinth, with rail arrangement as per standard engineering practice, depending upon soil condition etc complete, as per drawing and direction of Engineer in charge.

-

-

-

... More
5MVA transformer mounting plinth foundation (size : 3.1mx3.1mx1.5m)

1

91731

91730.5

... More
Providing & construction of FIRE FIGHTING wall between two transformer per instruction, burnt oil pit) tank of suitable capacity (5 MVA X-MER ),Guide line Detail technical specifications. Design to be approved by EIC.

1

32132

32132

... More
Transformer yard: Supply Installation, testing & commissioning of 150 mm thick layer of Morum and 200 thick layer of 40 mm metalling work in yards(15 mts x 10 mts) arrangement to removal of water logging in yard and providing & laying G.I.pipe line for watering to each earth pit from water tank. as per specifications per Detail's instruction, Guide line Detail technical specifications. (Drg & Design to be approved by EIC).

1

50100

50100

... More
Transformer yard Fencing: Supply & fixing unclimbable galvanised steel chain link mesh fencing confirming to latest relevant IS code opening size 75x75 mm, 2.4 Mtr hight made of 8 SWG GI wire fixed to MS angle post of size 65x65x6 mm, 2.85 Mtrs above GL/ Yard level, embedded 600mm in CC 1:3:6 (400x400) mm below GL at 2.5 Mtr center to center and 20 cm thick (200 mm height, above GL and 200 below GL) brick masonry in plinth & foundation with cement mortar 1:6 including diagonal struts at corner and at every 7th post of angle 65x65x6 mm and horizontal bracing of MS angle of 45x45x6 mm at top and bottom between each vertical post including painting with Aluminum painting with 2 coats on posts struts and chain link mesh 75x75x8 SWG mm size complete & providing and fixing 3 rows of barbed wire minimum weight 9.38 Kg per 100 RM etc complete, as per direction of Engineer in charge.

70

239148

3416.4

... More
Providing & fixing curbing stone & construction of earth pits, chamber cover watering arrangement to nearby water source for Control room etc, as per technical specification complete, as per direction of Engineer in charge.

10

8484

848.4



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.