Ministry Of Road Transport And Highways Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Ministry Of Road Transport And Highways - MORTH Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date17 Dec 2024
Closing Date16 Jan 2025
Tender Amount₹ 89,96,82,000 
Notes
Download

Costs

Summary

Construction And Up Gradation To Two/four Lane With Paved Shoulder In Km 70.450 To 80.720

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation in Ordinary Rock with Dozer with lead upto 1000 metres (Excavation for roadway in ordinary rock by deploying a dozer, including cutting and transporting the earth to site of embankment/dumping area with lead upto 1000 metres, trimming bottom and side slopes in accordance with the requirements of lines, grades and cross sections as per relevant clauses of section 300)

198000

-

-

... More
Material Deposited from Roadway Cutting Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material / selected soil having effective CBR 5 ( unless specified otherwise in contract ) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2) as per clause 305.

104580

-

-

... More
EARTH FILLING Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material / selected soil having effective CBR 5 ( unless specified otherwise in contract ) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2) as per clause 305.

82173.69

-

-

... More
SUB GRADE Construction of Sub-grade with Material Obtained from Borrow Pits (Construction of sub-grade with approved material / selected soil having effective CBR 8 ( unless specified otherwise in contract ) obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2) as per clause 305.

94515.6

-

-

... More
Granular Sub-base with Close Graded Material (Table:- 400-1) Plant Mix Method with Mechanically crushed stone only(Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 ) iii GSB grading-III Material 1st layer

14737.85

-

-

... More
vi GSB grading-VI Material 2 nd layer

13983.25

-

-

... More
WMM Grade 250mm Wet Mix Macadam / Interlocking layer laying using by Grader (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.) as per clause 406.

32380.33

-

-

... More
PRIME COAT Prime Coat over WMM/WBM (Providing and applying primer coat with bitumen emulsion or cutback bitumen on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.85 kg/sqm using mechanical means as per clause 502 & 112)

110984.63

-

-

... More
Surface Dressing (Providing and laying surface dressing as wearing course in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-40 laid on prepared surface and rolling with 8-10 tonne smooth wheeled steel roller) as per clause 509 & 112. 13 mm nominal size chipping with bitumen @ 1.0 kg/m2

3105

-

-

... More
TACK COAT Tack coat (Providing and applying tack coat with bitumen emulsion RS-1, grade confirming to IS:8887 using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom) as per clause 503 & 112. ii Tack coat for DBM @0.30 kg/sqm

114089.63

-

-

... More
Tack coat for BC @0.25 kg/sqm

104797.35

-

-

... More
DENSE BITUMINIOUS CONCRETE 50MM BITUMEN GRADE VG - 40 Dense Graded Bituminous Macadam (Providing and laying dense graded bituminous macadam with 120 -200 TPH higher capacity Batch Type HMP using crushed aggregates of specified grading, premixed with bituminous binder VG-40 by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 & 112 complete in all respects)

9488.95

-

-

... More
BITUMINIOUS CONCRETE, 30MM THICK WITH BITUMEN GRADE VG - 40 Bituminous Concrete (Providing and laying bituminous concretewith120 -200 TPH higher capacity Batch Type Hot Mix Plant using crushed aggregates of specified grading, premixed with bituminous binder VG-40 and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 & 112 complete in all respects)

3175.43

-

-

... More
HARD CRUST SHOULDER/GRANULAR SHOULDER Granular Shoulders (Construction of granular shoulder at top 150mm of earthen shoulder shall be well graded mix of at least 30% of granular sub-base material of grading-III as per clause 401 and moorum/gravel or soil and combination having soaked CBR value of not less than 30%. The granular layer shall be compacted to at least 98% of mix dry density of material as determined as per IS:2720 (Part-B))

4592.25

-

-

... More
Hot applied Thermoplastic Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)

3734.13

-

-

... More
Kilometre Stone Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) i 5th kilometre stone (precast)

2

-

-

... More
Ordinary kilometer stone

8

-

-

... More
Hectometer stone

40

-

-

... More
Hazard Markings @ Bridge start and end point Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming toIRC-79 and the drawings.

54

-

-

... More
Traffic signages Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of retro- reflective type sheeting and vide clause 801.3, 2mm thick aluminium sheeting, 3mm/4mm thick Aluminum composite material sheet depending on the size of the sign fixed over back support frame of min 40 x 40 x 5mm Angle mounted on a mild steel circular pipe 65 NB ,3.2 mm thicknness firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and painting all components of the signs and supports as per clause 7.2 of IRC:67 ) i 1200 mm Equilateral Triangle

2

-

-

... More
90 cm Equilateral Triangle

32

-

-

... More
90 cm high octagon

20

-

-

... More
80cmx60cm rectangle

40

-

-

... More
90 cm circular

26

-

-

... More
75 cm x 90 cm rectangular (single chevron with double plate in singe post)

140

-

-

... More
Direction Signs Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorised sign asper IRC :67 made of retro- reflective type sheeting and vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm fixed over back support frame of min 35 x 35 x 3mm Angle mounted on a mild steel circular pipe 65 NB firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing)

27

-

-

... More
Cat eyes/Road studs Providing and fixing Raised Pavement Markers made of polycarbonate ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 Kg tested in accordance to ASTM D 4280 type H and complying to specifications of category A of MORT&H (RW/NH-33023/10/97-DO III Dtd. 11.06.1997). The pavement markers will be auto moulded by dual polymer shanks and must comply with all the MoRT&H specifications. The height, width and length shall not exceed 50 mm, 100 mm and 100 mm respectively and with minimum reflective area of 13 Sq.cm. on each side and slope to the base shall be 35 +/-5 degree. The strength of detachment of the integrated cylindrical shanks (of diameter not less than 19 +/- 2 mm and height not less than 30 +/- 2 mm) from the body is to be a minimum value of 500 kgf. Fixing will be by drilling holes on road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the Engineer-in-charge.

3054

-

-

... More
Providing & Fixing Delineator made of M.S. Hollow Rectangular Pipe (Conforming to IS: 4923) of cross section 100 mm x 80 mm, thickness 4mm, of 1.10 meter length. The top of the hollow pipe, welded and closed with 16 gauge M.S. Sheet. The height of the Delineator above ground level should be between 0.8 meter and 0.9 meter and 0.20 to 0.30 m below ground. The bottom of the delineator should be provided with holdfast of length 15cm on each side. Delineator should be painted with coat of Zinc Chromate stoving Prime and two coats of Black Stove Enamel (Oven Baked) paint with 3nos. 15 cm bands of white Retro-reflective Sheeting of Engineering Grade pasted around the pipe and 2 Nos. High intensity Grade Retro-reflective Sheeting of size 8 cm x 10cm pasted on the top of each side of Delineator and treated With HLVA & fixing the same in M-15 grade concrete block of size 45x43x30cms including transportation etc. complete. The construction and placement of the delineator must be as per IRC: 79.

1400

-

-

... More
"W" : Metal Beam Crash Barrier Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level firmly fixed to the ground by means of foundation with M-15 grade cement concrete 30 x 30 x 110 cm, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with aspacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811)

3640

-

-

... More
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98-2011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts ,joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. ii Double row for two utility service across the road

1500

-

-

... More
Construction of RCC open drain with minimum size of 1m x 1m inside dimension and size varying as per site requirement lined with 150 mm thick RCC M-20 walls ,150 mm thick RCC, M-20 foundation, over 100 mm thick ( Av) levelling course in PCC M-15 including excavation, dressing of sides and bottom , providing HYSD reinforcement consisting of 10mm dia horizontal bars @ 150 mm c/c and L-shaped 10 mm dia vertical bars @ 150 mm c/c ( L= 1400 m ) including cutting,bending and binding wires, placing in position, providing shuttering and concreting by using cocrete mixer , compaction by vibration etc complete as per drawings and technical specifications.

3000

-

-

... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications .every 10 meter open 1meter gape. PCC M-20

324

-

-

... More
supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications

18.76

-

-

... More
providing and fixing guard stones 200 x 200 x 900 mm made of precast RCC M-20 grade fixed at 300 mm into the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400 mm and given two coats of paint with white and black bands including excavation.

364

-

-

... More
Retaining Wall Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)

4278

-

-

... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications

587

-

-

... More
With Batching Plant, Transit Mixer and Manual placing PCC M-20 .Toe wall

1673.1

-

-

... More
Plain/Reinforced cement concrete in sub structure complete as per drawing and technical specifications Toe/Retaining Wall

5454.33

-

-

... More
supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications

545.43

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness not less 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

2160

-

-

... More
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications

2050

-

-

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A.Grannular material

6525

-

-

... More
Bridge & Culverts Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres) 1) Wearing Course

356.04

-

-

... More
2) Kerb Stone

192.4

-

-

... More
3) Prestressed / Reinforced cement concrete grade M-20 & aboveSuperstructure (RCC)

432.81

-

-

... More
4) Substructure (Stone)

872.53

-

-

... More
5) Foundation (Stone)

4927.44

-

-

... More
6) PCC below Foundation

259.69

-

-

... More
1) Wearing Course

15.6

-

-

... More
2) HPC

96

-

-

... More
3) Cushion

92.16

-

-

... More
4) Head Wall

180.96

-

-

... More
Clearing Grass and Removal of Rubbish (Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area)

3.47

-

-

... More
Excavation Work Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)

7829.12

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification

2647.73

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical SpecificationsPCC- M15 levelling course

815.67

-

-

... More
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification approach slab

281.1

-

-

... More
Reinforced cement concrete approach slab with RCC grade M-30 including reinforcement and formwork complete as per standard drawing of MoRTH and Technical specification.

787.5

-

-

... More
Plain/Reinforced Cement Concrete for wall & slab etc. complete as per Drawing and Technical Specifications M-35

3405

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications

406.36

-

-

... More
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.)

750

-

-

... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications (75 mm thick)

166.18

-

-

... More
Providing weep holes in BricK masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications

1356.8

-

-

... More
Drainage Spouts complete as per drawing and Technical specification

88

-

-

... More
Providing and laying Pitching Stone/Boulder on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per clause 2504

402.78

-

-

... More
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications stone/Boulder

700

-

-

... More
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification including trimming of slopes to proper profile and preparation of bed and as per clause 2504.

201.32

-

-

... More
Providing and laying Flooring complete as per drawing and Technical specifications laid over cement concrete bedding.

681.18

-

-

... More
Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall

2554.35

-

-

... More
Crash Barriers (Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-25 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified)

263

-

-

... More
Curtain wall complete as per drawing and Technical specificationPCC Grade M15

971.02

-

-

... More
Construction of Sub-grade with Material Obtained from Borrow Pits (Construction of sub-grade with approved material / selected soil having effective CBR 8 ( unless specified otherwise in contract ) obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2) as per clause 305

7798.89

-

-

... More
Plain/Reinforced Cement Concrete for wall & slab etc. complete as per Drawing and Technical Specifications.Footpath RCC M25

281.25

-

-

... More
Plain/Reinforced Cement Concrete for wall & slab etc. complete as per Drawing and Technical Specifications.ith Batching Plant, Transit Mixer and Concrete Pump RCC Grade M25

112

-

-

... More
Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specificationsW-Beam Crash Barrier

1000

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical SpecificationsToe Wall - PCC Grade M15

174.9

-

-

... More
Diversion Road Construction of Sub-grade with Material Obtained from Borrow Pits (Construction of sub-grade with approved material / selected soil having effective CBR 8 ( unless specified otherwise in contract ) obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2) as per clause 305

22525

-

-

... More
GSB Plant Mix Method with Mechanically crushed stone only(Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage ofmixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 )

2388

-

-

... More
Wet Mix Macadam / Interlocking layer laying using by Grader (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadamspecification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.) as per clause 406.

978.75

-

-

... More
Prime Coat over WMM/WBM (Providing and applying primer coat with bitumen emulsion or cutback bitumen on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.85 kg/sqm using mechanical means as per clause 502 & 112) .with bitumen emulsion (SS-1, grade confirming to IS:8887) @0.85 kg/sqm

4350

-

-

... More
Tack coat (Providing and applying tack coat with bitumen emulsion RS-1, grade confirming to IS:8887 using emulsion pressure distributor on the prepared bituminous surface cleaned withmechanical broom) as per clause 503 & 112

4350

-

-

... More
MSS Type B Close Graded Premix Surfacing/Mixed Seal Surfacing (Mechanical means using HMP of 120 -200 TPH capacity . Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness using viscocity grade bitumen VG-40 to the required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a Smooth wheeled roller and finishing tO required level and grade. ) as per clause 508 & 112.

4350

-

-

... More
Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row . (Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 1000 Dia.

340

-

-

... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)

5326.45

-

-

... More
Plain/Reinforced cement concrete in sub structure complete as per drawing and technical specificationsPCC M-15 Below Retaining wall

143.77

-

-

... More
Plain/Reinforced Cement Concrete for wall & slab etc. complete as per Drawing and Technical Specifications.RCC M35 For Retaining wall

1452

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications

15.51

-

-

... More
(A) FOUNDATION Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I) Ordinary soil A) Manual Means (i) Upto 3 m depth

668.77

-

-

... More
Add extra 20% in the rates of above items for dewatering (Assessment of dewatering shall be made as per site condition ) L.W.L. 92.300

235.22

-

-

... More
3 m to 6m depth depth

69.41

-

-

... More
Providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing and specifications as per section 1200 and 1900.

70.63

-

-

... More
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m as per section 1100 and 1700. Pile diameter-1200 mm

654.2

-

-

... More
Pile Load Test on single Vertical Pile in accordance with IS:2911(Part-IV) in static load method only. (i) Initial and routine load test

750

-

-

... More
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification D Using Batching Plant, Transit Mixer and Concrete Pump i) RCC Grade M35

607.39

-

-

... More
Levelling course for Pile cap (Providing and laying of PCC M15 levelling course 100mm thick below the pile cap.)With Batching Plant, Transit Mixer and Concrete Pump

50.62

-

-

... More
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications

154.66

-

-

... More
Taking exploratory boring 100 mm dia at the location of piers and abutments or for high embankments in approaches in all types of strata as per I.R.C. 78-1983 and section 2400 of specifications.

90

-

-

... More
(B) SUB STRUCTURE Plain/Reinforced cement concrete in sub structure complete as per drawing and technical specifications H Height upto 5m With Batching Plant, Transit Mixer and Concrete Pump (i) R.C.C. Grade M-35

358.13

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications

35.81

-

-

... More
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications

11500

-

-

... More
(C) SUPER STRUCTURE Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification . D RCC/PSC Grade M 35 II For T-beam & slab Using Batching Plant, Transit Mixer and Concrete Pump (ii) Height 5m to 10m

854.98

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications

119.7

-

-

... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications

104.4

-

-

... More
Drainage Spouts complete as per drawing and Technical specification

30

-

-

... More
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification With Batching Plant, Transit Mixer and Concrete Pump

16.8

-

-

... More
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification

33.6

-

-

... More
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.)

96

-

-

... More
Painting on kerbs in black and yellow alternate bands including cost of material and labour complete as per drawings and specifications as per clause 803.with Road marking paints With Road Marking Paint

207

-

-

... More
Providing and Fixing of Av. 20mm thick Granite plate including cutting and polishing and inscribed details as per approved drawing i/c engraving the matter as desired.

4

-

-

... More
Testing of span of bridge for deflection due to live load with platform for loading arrangements, apparatus for measurement etc. complete as per drawing and specifications (As per I.R.C.S.P.51)

77

-

-

... More
Providing and fixing for hand railing top of crash barrier including cost of material complete as per approved drawing.

214

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.