Jila Nirman Samiti Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Jila Nirman Samiti - JNSJ Tender

Civil And Construction
Building Construction
Opening Date9 Nov 2022
Closing Date28 Nov 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).

142.23

-

2970

... More
Providing and laying nominal mix reinforcement cement concrete with crushed stone aggregate using concrete mixer in all works upto floor five level excluding cost of reinforcement and form work.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

519.43

-

4163

... More
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:G.Floor

384.6

-

97.5

... More
F. Floor

134.83

-

195

... More
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:Thermo-Mechanically treated bars

60773.31

-

54.5

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: foundations,footings,base of columns and plinth beam in any shape and sizes

537.66

-

139

... More
Columns, Pillars, Piers and likes- rectangular or square in shape

1122.12

-

356

... More
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)

1307.64

-

235

... More
Beams, lintels, cantilevers & walls

1473.86

-

202

... More
Stair cases of all types excluding spiral and folded plate type, including risers and landings

55.2

-

230

... More
Brick work with modular well burnt (open bhatta) clay bricks of crushing strength not less than 20 kg/sqcm and water absorption not more than 25% in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Coarse Sand)

99.79

-

3263

... More
Extra for brick work in superstructure:Above plinth for evary floor or part there of in addition to rate for foundation and plinth: G.Floor

268.56

-

3384

... More
F. Floor

221.08

-

3505

... More
Half brick thick brick masonry with modular well-burnt clay bricks of crushing strength not less than 25 kg/sqcm and water absorption not more than 20% in superstructure above plinth level upto floor five level.Cement Mortar 1:4 (1 cement : 4 coarse sand)

84.29

-

417

... More
Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry.

84.29

-

62.5

... More
Providing and fixing M.S. bright finished or black enameled Tower bolts (Barrel type) with necessary iron screws: 250 mm

72

-

34.5

... More
200 mm

36

-

29

... More
Providing and fixing M.S. bright finished or black enameled handles with necessary iron screws: 125 mm

72

-

51

... More
Providing and fixing aluminium door mounted door stopper with necessary nickle plated iron screws etc complete. 100 mm long

36

-

45

... More
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Angle-iron frames

2726.15

-

73.5

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat of red oxide zinc chromate primer..

3503.6

-

67.5

... More
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

5452.29

-

75

... More
6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand)

1300.98

-

87

... More
12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

3497.92

-

91.5

... More
15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)

124.65

-

107

... More
18 mm thick cement plaster with under layer of 12mm thick cement plaster 1:5 (1 cement : 5 fine sand) finished with a top layer of 6mm thick cement plaster 1:3 (1 cement : 3 fine sand).

1426.86

-

163

... More
Provide & Laying DUBLE/MULTI CHARGE (minimaum 2.0mm thick layer)VITRIFIED floor tiles with water absorption less than 0.05% and conforming to IS : 15622-2017 of 1st quality of apprived make in all colours and shade and size mentioned below (+/- 10mm) laid on 20mm thick ce,emt mortal 1:4 ( 1 cement : 4 coarse sand) including frouting the joints with white cement and matching pigments etc. complet. Size 600x600 thickness 9 to 10mm

1510.74

-

1082

... More
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.Size upto 200x300mm

129.01

-

587

... More
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement..40 mm thick

865.64

-

222

... More
White washing with lime to give an even shade.On new work (Three or more coats)

6225.76

-

9.4

... More
Providing and applying 2mm thick ready mix exterior grade putty (Birla wall care, Alltek Superfine W/R of (NCL), J.K. wall putty) on walls to make the surface smooth and even.

6225.76

-

94.5

... More
Distempering with acrylic washable distemper to give an even shade.On new work (Two or more coats)

4798.9

-

38

... More
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

1426.86

-

56

... More
Painting on new work (two or more coats) to give an even shade with:Satin synthetic enamel paint (top most approved branded quality)

378.61

-

55

... More
Providing and fixing powder coated aluminium door latch with 12mm rod, necessary M.S. nuts bolts and screws etc complete.300x12mm

72

-

75

... More
Providing and fixing stainless steel butt hinges with necessary stainless steel screws etc complete.150x2.5mm (heavy)

108

-

97.5

... More
Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with sand including finishing the top smooth.

151

-

273

... More
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.

10.8

-

3330

... More
Providing and fixing M.S. bright finished or black enameled sliding door bolts with bolts, nuts and necessary iron screws:300x16mm

26

-

135

... More
Providing and fixing M.S. bright finished or black enameled hooks and eyes with necessary iron screws:250 mm

98

-

74

... More
Providing and mixing water proofing material in PCC/ RCC work in the proportion recommended by the manufacturer.

1315.62

-

43.5

... More
Chequerred terrazzo tiles 25 mm thick with graded marble chips of size upto 6mm in floors on 25mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles including grinding rubbing and polishing complete.Dark shade using ordinary cement

68.66

-

669

... More
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of brackets, cutting and making good the wall wherever required :Size 600x450x200mm

6

-

4502

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Long pattern W.C. pan of size 580 mm

5

-

2459

... More
Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet:250x130x30 mm

5

-

270

... More
Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan including cutting and making good the walls and floors wherever required: White wall hung type

1

-

4589

... More
Providing and fixing 10 litre capacity P.V.C. low level flushing cistern conforming to IS : 7231, with all fittings and fixtures complete.White

5

-

729

... More
Providing and fixing ISI marked plastic seat with lid for pedestal type W.C. pan complete:White

1

-

620

... More
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete:Flat back half stall urinal of size 460x380x250mm

9

-

1776

... More
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required :White Size 550x450 mm

10

-

1430

... More
Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

5

-

272

... More
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. :For 100 mm dia pipe

30

-

85.5

... More
For 75 mm dia pipe

20

-

83

... More
Providing and fixing sand cast iron S&S bend with access door of required degree as per IS : 1729, insertion rubber washer 3 mm thick, bolts and nuts:100 mm dia

30

-

418

... More
75 mm dia

20

-

316

... More
Providing and fixing sand cast iron S&S trap of self cleansing design with screwed down or hinged grating with or without vent arm as per IS: 1729 complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outlet

5

-

562

... More
Providing and fixing on wall face UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.110 mm dia pipe.

300

-

267

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Tee/Tee with door/Bend 45°/Bend 90° 110 mm

15

-

154

... More
Double "Y" with or without door 110 mm

15

-

224

... More
110 mm

7

-

44

... More
Access Door Cap 110 mm bend

10

-

59

... More
"P" trap 110mmx110mm long

5

-

227

... More
Nahani trap 110x75mm

10

-

90.5

... More
Multi floor trap 110

10

-

122

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL 15 mm dia. nominal bore

35

-

110

... More
20 mm dia. nominal bore

50

-

151

... More
25 mm dia. nominal bore

150

-

199

... More
32 mm dia. nominal bore

60

-

271

... More
40 mm dia. nominal bore

150

-

362

... More
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (450gms)

15

-

382

... More
Two way bib cock (800gms)

11

-

708

... More
Stop cock (concealed) (600gms)

5

-

494

... More
Angle valve for basin mixer and geyser points (450gms)

3

-

382

... More
Basin mixer pillar tap with spout (1000gms)

5

-

1248

... More
Toilet paper holder

15

-

248

... More
Soap dish plate

15

-

163

... More
Towel rail (600mm long x 20mm dia)

15

-

338

... More
Providing and fixing stainless steel drain jali of approved make/quality.

18

-

51

... More
Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) :40 mm nominal bore

8

-

596

... More
Providing and placing on terrace (at all levels) polyethylene water storage tank ISI marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

5000

-

7.3

... More
Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :

5

-

754

... More
Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :

6

-

4644

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design:150 mm diameter S.W. pipe

50

-

436

... More
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/ cm², water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :100x100 mm size P type

5

-

1339

... More
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/ cm² in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) ::

3

-

6703

... More
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

2

-

1709

... More
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.In all types of soil

12

-

185

... More
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).

0.8

-

2970

... More
Brick work with modular well burnt (open bhatta) clay bricks of crushing strength not less than 20 kg/sqcm and water absorption not more than 25% in foundation and plinth in: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand)

4.03

-

3263

... More
Providing and making 12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 5 fine sand)

20.16

-

91.5

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:5 (1 cement : 5 fine sand)

20.16

-

107

... More
Neat Cement punning.

20.16

-

33

... More
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

1.38

-

4163

... More
Providing and fixing form work including centring, shuttering, strutting staging, propping bracing etc. complete and including its removal at all levels, for:Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)

11.52

-

235

... More
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:Thermo-Mechanically treated bars FE 415

124.42

-

54.5

... More
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.110 mm dia pipe.

359.75

-

267

... More
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm

60

-

154

... More
Double "Y" with or without door 110 mm

40

-

224

... More
Supplying, filling, spreading & leveling stone boulders/ Gravels/ Coarse sand, in recharge pit, in the required layers and thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (excavation of pit will be paid separately).Stone boulders of size range 5 cm to 20 cm, in recharge pit

2.4

-

863

... More
Gravels of size range 5 mm to 10 mm, over the existing layer of boulders

2.4

-

806

... More
Coarse sand of size range 1.5 mm to 2 mm over existing layer of gravel

2.4

-

471

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For fixed portion

240

-

331

... More
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/neoprene gasket required (Fittings shall be paid for separately).

75.6

-

338

... More
Providing and fixing S.S. finished brass hard drawn hook & eyes with necessary S.S. finished MS screws complete:150 mm

100

-

53.5

... More
Painting on new work (two or more coats) to give an even shade with:Satin synthetic enamel paint (top most approved branded quality)

95.96

-

55

... More
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.In all types of soil

15.4

-

185

... More
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size)

5.53

-

2970

... More
Providing and laying nominal mix reinforcement cement concrete with crushed stone aggregate using concrete mixer in all works upto floor five level excluding cost of reinforcement and form work.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size)

13.38

-

4163

... More
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:Thermo-Mechanically treated bars

1070.4

-

54.5

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:foundations,footings,base of columns and plinth beam in any shape and sizes

20.62

-

139

... More
Columns, Pillars, Piers and likes- rectangular or square in shape

24.96

-

297

... More
Beams, lintels, cantilevers & walls

55.37

-

202

... More
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)

24.39

-

235

... More
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.

15.4

-

65

... More
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.

21.95

-

371

... More
Brick work with modular well burnt (open bhatta) clay bricks of crushing strength not less than 20 kg/sqcm and water absorption not more than 25% in foundation and plinth in:

4.07

-

3263

... More
Extra for brick work in superstructure:Above plinth for evary floor or part there of in addition to rate for foundation and plinth:

14.81

-

3384

... More
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Angle-iron frames

182.12

-

73.5

... More
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.

364.23

-

75

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat of red oxide zinc chromate primer..

122.4

-

67.5

... More
6mm thick cement plaster of mix:In Cement mortar 1:4 (1 cement : 4 fine sand)

24.39

-

87

... More
12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)

104.35

-

91.5

... More
15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)

67.8

-

107

... More
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement..40 mm thick

24.39

-

222

... More
White washing with lime to give an even shade.On new work (Three or more coats)

128.74

-

9.4

... More
Distempering with acrylic washable distemper to give an even shade.On new work (Two or more coats)

128.74

-

38

... More
Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tube well within the selected habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable)

1

-

1502

... More
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level.All types of soil 150 mm dia.

80

-

339

... More
Rocky strata including Boulders. 150 mm dia.

70

-

396

... More
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level.All types of soil Rocky strata including Boulders.Rocky strata including Boulders.150 mm dia.

60

-

424

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) slotted pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in-charge.150 mm nominal size dia.

70

-

546

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of:150 mm dia

1

-

217

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp.

1

-

1055

... More
Providing ISI Mark 32 mm dia G.I. ( B class) riser pipe and M.S. plunger rod in 3 meter length socketed on one end as per IS: 1239 ( Part I) 1990 with up to date amendments and socket as per IS: 2062/1990 up to date amendments.

150

-

275

... More
Providing and placing in position India Mark II hand pump with 32 mm diameter riser pipe assembly complete with all accessories (riser pipe and plunger rod to be paid separately).

1

-

6114

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

1

-

654

... More
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.In all types of soil

155.52

-

185

... More
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).

15.55

-

2970

... More
Providing and laying nominal mix reinforcement cement concrete with crushed stone aggregate using concrete mixer in all works upto floor five level excluding cost of reinforcement and form work.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

9.33

-

4163

... More
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:Thermo-Mechanically treated bars

933.12

-

54.5

... More
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)

38.88

-

235

... More
Brick work with modular well burnt (open bhatta) clay bricks of crushing strength not less than 20 kg/sqcm and water absorption not more than 25% in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Coarse Sand)

18.72

-

3080

... More
15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

336.96

-

107

... More
Neat Cement punning.

168.48

-

33

... More
25mm thick cement concrete flooring with 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with floating cost of neat cement.

30

-

165

... More
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.In all types of soil

54

-

185

... More
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).

10.8

-

2970

... More
Brick work with modular well burnt (open bhatta) clay bricks of crushing strength not less than 20 kg/sqcm and water absorption not more than 25% in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Coarse Sand)

24

-

3080

... More
15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)

288

-

107

... More
25mm thick cement concrete flooring with 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with floating cost of neat cement.

60

-

165

... More
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point

67

-

266

... More
Medium Point

134

-

424

... More
Long Point

104

-

588

... More
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

2

-

420

... More
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)

61

-

216

... More
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.3 Long Point

4

-

922

... More
Extra Long Point I

4

-

1302

... More
Extra Long Point II

5

-

1657

... More
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.1 Short Point

3

-

589

... More
Medium Point

5

-

942

... More
Long Point

4

-

1350

... More
Extra Long Point I

6

-

1807

... More
Extra Long Point II

4

-

2315

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.2 3 X 2.5 sq. mm in 20mm conduit

238

-

111

... More
6 X 2.5 sq. mm in 25mm conduit

145

-

172

... More
9 X 2.5 sq. mm in 32mm conduit

125

-

238

... More
12 X 2.5 sq. mm in 32mm conduit

82

-

288

... More
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.8 Fan regulator (one module size) electronic stepped type moving all rounds

90

-

186

... More
Batten/ angle holder

83

-

41

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 Deluxe

2

-

107

... More
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 1200 mm sweep

90

-

1697

... More
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep

4

-

2446

... More
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.4 9 Watt

16

-

143

... More
12 Watt

67

-

215

... More
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt {4 feet}

115

-

443

... More
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.5 36 watt

8

-

2359

... More
45 watt

3

-

2729

... More
Providing and fixing wooden board of suitable size (18''x 24'') for energy meter etc complete as per specification.

1

-

123

... More
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.1 Upto 300 mm deep

3

-

6818

... More
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.21.1 100 amp (20x3mm)

5

-

1319

... More
200 amp (25x5mm)

3

-

2382

... More
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.1 3 pole MCCB, 25-63A, Fixed Thermal Release, 10KA

6

-

1483

... More
3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA

1

-

12006

... More
Supplying and fixing on surface/ recess vertical type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, with 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland/ knock out plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 9.5.4 4 way (4 + 12), Double door

6

-

4149

... More
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.12.2 6 amps to 32 amps

-

-

411

... More
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.16.3 40 amps

4

-

1275

... More
63 amps

2

-

1316

... More
Providing and fixing metal clad, 4 pole, on load change over switch unit (with sheet steel enclosure), 415/500 volts, in cubicle panel including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. (Connecting lead if required shall be paid separately) 1.7.3 200 amps

1

-

11772

... More
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.4 315/5 amps

3

-

356

... More
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.

3

-

94

... More
Providing and fixing penal mounting following rating analog type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.18.4 0-500 amps

1

-

458

... More
Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification.

1

-

1201

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)

1

-

6209

... More
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification.

12

-

77

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification.

210

-

19

... More
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.1.1 63 mm outer dia and 50 mm Inner dia

190

-

184

... More
75 mm outer dia and 60 mm Inner dia

85

-

203

... More
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.3.15 3.5 x 50 sq. mm.

82

-

173

... More
4 x 16 sq. mm.

187

-

103

... More
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. 15.28.3 16 sq. mm

48

-

19

... More
50 sq. mm

4

-

21

... More
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification.

4.5

-

168



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.