Chhattisgarh Medical Services Corporation Limited Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Chhattisgarh Medical Services Corporation Limited - CGMSC Tender

Works
Civil And Construction
Building Construction
Opening Date5 Feb 2024
Closing Date26 Feb 2024
Tender Amount₹ 1,16,93,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
For Foundation

-

-

-

79.35

-

-

198.45

-

-

... More
SEPTIC TANK

72

-

-

... More
Extra rate for lead for every 50m lead or part thereof and upto 150 m beyond 50 m free lead and 1.5 m free lift by manual means only.

-

-

-

... More
For Rocks.

-

-

-

... More
4 TIMES

1399.2

69260

49.5

... More
Extra for every additional lift of 1.5 m or part thereof.

-

-

-

... More
All types of soils

-

-

-

... More
SEPTIC TANK

9

238

26.5

... More
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).

800

5760

7.2

... More
Providing and filling in plinth with sand/ Crusher dust and hard moorum

-

-

-

79.35

-

-

198.45

-

-

... More
HEMATOLOGY BIOCHEMISTRY AREA

145.51

-

-

... More
STAIRCASE

26.96

-

-

... More
STAFF ROOM

21.25

-

-

... More
PATHOLOGY LAB

21.98

-

-

... More
PASSAGE

8.64

-

-

... More
FNAC ROOM

11.09

-

-

... More
PHLEBOTOMY ROOM-1

9.7

-

-

... More
PHLEBOTOMY ROOM-2

9.7

-

-

... More
PHLEBOTOMY ROOM-3

9.7

-

-

... More
PASSAGE

37.8

-

-

... More
LOCKER SHOE RECK

18.23

-

-

... More
TOILET

18

-

-

... More
MALE TOILET

22.87

-

-

... More
FEMALE TOILET

16.07

-

-

... More
REGISTRATION/ WAITING AREA

49.54

-

-

... More
PLINTH PROTECTION

49.73

-

-

... More
Deduct for Footing Base

-

-

-

-7.93

-

-

-19.85

-

-

... More
Deduct for Footing Concrete

-

-

-

-20

-

-

-38.88

-

-

... More
Deduct For Column concrete

-

-

-

-2.04

-

-

-5.13

-

-

... More
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:

-

-

-

... More
Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.

-

-

-

... More
FOR FOOTING BASE

-

-

-

6.9

-

-

18.9

-

-

... More
FOR FOOTING

-

-

-

20

-

-

43.2

-

-

... More
FOR COLUMN UP TO NGL

-

-

-

5.4

-

-

16.2

-

-

... More
PLINTH BEAM, HORIZONTAL AXIS

-

-

-

49

-

-

42.5

-

-

63

-

-

... More
VERTICAL AXIS

-

-

-

133

-

-

... More
Columns, Pillars, Piers and likes- rectangular or square in shape

-

-

-

... More
COLUMN UP TO PLINTH LVL

-

-

-

7.2

-

-

21.6

-

-

... More
COLUMN UP G.F. SLAB LVL

-

-

-

21.6

-

-

64.8

-

-

... More
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)

-

-

-

-

-

-

... More
HEMATOLOGY BIOCHEMISTRY AREA

121.26

-

-

... More
STAFF ROOM

17.71

-

-

... More
STAIRCASE

14.07

-

-

... More
COMMON TOILET

22.47

-

-

... More
MALE TOILET

19.06

-

-

... More
FEMALE TOILET

13.39

-

-

... More
PASSAGE

63

-

-

... More
PATHOLOGY LAB

18.31

-

-

... More
FNAC ROOM

9.24

-

-

... More
PHLEBOTOMY ROOM1

8.09

-

-

... More
PHLEBOTOMY ROOM2

8.09

-

-

... More
PHLEBOTOMY ROOM3

8.09

-

-

... More
PASSAGE

14.1

-

-

... More
WAITING AREA

41.28

-

-

... More
Beams, lintels, cantilevers & walls

-

-

-

... More
Lintel Beam, HORIZONTAL AXIS

-

-

-

24.56

-

-

14.16

-

-

5.32

-

-

4.96

-

-

1.36

-

-

... More
Lintel Beam, VERTICAL AXIS

-

-

-

10.64

-

-

2.22

-

-

8.5

-

-

8.88

-

-

1.08

-

-

1.26

-

-

5.32

-

-

... More
Slab Beam, HORIZONTAL AXIS

-

-

-

61.4

-

-

17.7

-

-

13.3

-

-

12.4

-

-

13

-

-

28.2

-

-

4.2

-

-

6.4

-

-

... More
Slab Beam, VERTICAL AXIS

-

-

-

53.2

-

-

27.75

-

-

22.2

-

-

... More
Weather shade, chhajja, Cornices and mouldings

-

-

-

14.82

-

-

15.96

-

-

3.6

-

-

... More
Stair cases of all types excluding spiral and folded plate type, including risers and landings

-

-

-

... More
FIRST FLIGHT

9

-

-

... More
LANDING

9

-

-

... More
SECOND FLIGHT

6.75

-

-

1.35

-

-

... More
LANDING

0.67

-

-

5.4

-

-

... More
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.

-

-

-

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).

-

-

-

... More
for Footing Base

-

-

-

5.29

-

-

13.23

-

-

... More
SEPTIC TANK

1.8

-

-

... More
PLINTH BEAM, HORIZONTAL AXIS

-

-

-

1.47

-

-

1.28

-

-

1.89

-

-

... More
VERTICAL AXIS

-

-

-

3.99

-

-

... More
ROOM BASE

-

-

-

... More
HEMATOLOGY BIOCHEMISTRY AREA

1.29

-

-

... More
STAFF ROOM

0.39

-

-

... More
STAIRCASE

0.34

-

-

... More
COMMON TOILET

0.54

-

-

... More
MALE TOILET

0.52

-

-

... More
FEMALE TOILET

0.52

-

-

... More
PASSAGE

0.18

-

-

... More
PATHOLOGY LAB

0.56

-

-

... More
FNAC ROOM

0.39

-

-

... More
PHLEBOTOMY ROOM1

0.39

-

-

... More
PHLEBOTOMY ROOM2

0.39

-

-

... More
PHLEBOTOMY ROOM3

0.39

-

-

... More
PASSAGE

0.15

-

-

... More
WAITING AREA

1.29

-

-

... More
PLINTH PROTECTION

5.53

-

-

... More
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

-

-

-

... More
FOR FOOTING

-

-

-

20

-

-

38.88

-

-

... More
COLUMN UP TO NGL

-

-

-

1.08

-

-

2.7

-

-

... More
PLINTH BEAM

-

-

-

... More
HORIZONTAL AXIS

-

-

-

... More
PLINTH BEAM, HORIZONTAL AXIS

-

-

-

4.9

-

-

4.25

-

-

6.3

-

-

... More
VERTICAL AXIS

-

-

-

13.3

-

-

... More
COLUMN UP TO PLINTH LVL

-

-

-

1.44

-

-

3.6

-

-

... More
COLUMN UP G.F. SLAB LVL

-

-

-

3.6

-

-

... More
COLUMN UP PARRAPET WALL

-

-

-

1.08

-

-

... More
Lintel Beam, HORIZONTAL AXIS

-

-

-

2.46

-

-

1.42

-

-

0.53

-

-

0.5

-

-

0.14

-

-

... More
Lintel Beam, VERTICAL AXIS

-

-

-

1.06

-

-

0.22

-

-

0.85

-

-

0.89

-

-

0.11

-

-

0.13

-

-

0.53

-

-

... More
Slab Beam, HORIZONTAL AXIS

-

-

-

6.14

-

-

1.77

-

-

1.33

-

-

1.24

-

-

1.3

-

-

2.82

-

-

0.42

-

-

0.64

-

-

... More
Slab Beam, VERTICAL AXIS

-

-

-

5.32

-

-

2.78

-

-

2.22

-

-

-

-

-

... More
HEMATOLOGY BIOCHEMISTRY AREA

15.16

-

-

... More
STAFF ROOM

2.21

-

-

... More
STAIRCASE

1.76

-

-

... More
COMMON TOILET

2.81

-

-

... More
MALE TOILET

2.38

-

-

... More
FEMALE TOILET

1.67

-

-

... More
PASSAGE

3.94

-

-

... More
PATHOLOGY LAB

2.29

-

-

... More
FNAC ROOM

1.16

-

-

... More
PHLEBOTOMY ROOM1

1.01

-

-

... More
PHLEBOTOMY ROOM2

1.01

-

-

... More
PHLEBOTOMY ROOM3

1.01

-

-

... More
PASSAGE

1.76

-

-

... More
WAITING AREA

5.16

-

-

... More
SEPTIC TANK

2.25

-

-

1.48

-

-

0.36

-

-

... More
FRONT CHHAJJA

0.8

-

-

... More
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

-

-

-

... More
qty same as above

199.49

19450

97.5

... More
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:

-

-

-

... More
Thermo-Mechanically treated bars FE 415

-

-

-

... More
@100kg/cum

23939.24

1304688

54.5

... More
Providing and laying damp proof course (upto 50mm thick) with plain

-

-

-

... More
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed

-

-

-

... More
stone aggregate 20mm nominal size) including form work.

-

-

-

... More
PLINTH BEAM, HORIZONTAL AXIS

-

-

-

0.49

-

-

0.43

-

-

0.63

-

-

... More
VERTICAL AXIS

-

-

-

1.33

-

-

... More
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:

-

-

-

... More
Cement Mortar 1:6 (1 cement : 6 coarse sand)

-

-

-

... More
Above Plinth Beam

-

-

-

... More
PLINTH BEAM, HORIZONTAL AXIS

-

-

-

... More
HORIZONTAL AXIS

3.92

-

-

... More
VERTICAL AXIS

2.66

-

-

... More
UP TO G.F. SLAB LEVEL

-

-

-

... More
Horizontal axis

36.84

-

-

... More
VERTICAL AXIS

23.94

-

-

... More
septic tank

3.36

-

-

... More
PLINTH PROTECTION

11.05

-

-

... More
Deduction

-

-

-

-4.68

-

-

-0.32

-

-

-6.3

-

-

-1.26

-

-

-3.02

-

-

-1.76

-

-

... More
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

-

-

-

... More
Above Quantity

160.58

19429

121

... More
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.

-

-

-

... More
40 mm. thick (single leaf)

-

-

-

5.04

-

-

21

-

-

... More
Providing and fixing stainless steel butt hinges IS : 12817 marked with necessary stainless steel screws etc complete.

-

-

-

... More
100x1.7mm (light)

-

-

-

8

-

-

40

-

-

... More
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete.

-

-

-

-

-

-

4

-

-

20

-

-

... More
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete.

-

-

-

... More
150 x10mm

-

-

-

8

-

-

40

-

-

... More
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete.

-

-

-

... More
100 mm

-

-

-

8

-

-

40

-

-

... More
Providing and fixing stainless steel fixed stopper with necessary stainless steel screws complete.

-

-

-

... More
100 mm long

-

-

-

4

-

-

20

-

-

... More
Providing and fixing factory made PVC door shutters of specified

-

-

-

... More
thickness made of styles and rails of a UPVC hollow section of specified

-

-

-

... More
size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on

-

-

-

... More
both sides. The styles and rails mitred and joined at the corners by means

-

-

-

... More
of M.S. galvanised/ plastic brackets of size 75x220 mm having wall

-

-

-

... More
thickness 1.0 mm and stainless steel screws

-

-

-

... More
30 mm thick door shutters with styles and rails of size 60x30 mm

-

-

-

18.48

45978

2488

... More
Providing and fixing factory made UPVC white colour casement three track three panels sliding window with fly proof s.s. wire mesh (two no. glazed & one no wire mesh panels) made of (big series) frame 116x45 mm & mesh 46x 62mm both having wall thickness of 2.3x 0.2mm and single glazing bead/ double glazing bead of appropriate dimension.(area of window above 1.75 sqm)

-

-

-

23.4

-

-

1.62

-

-

... More
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.

-

-

-

... More
channel gate 1

13.44

-

-

... More
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.

-

-

-

... More
Electric resistance or induction butt welded tubes Grade-250

-

-

-

... More
OD-60.3 MM OUTER DIA - 3.6 MM THICK(HOLLOW PIPE)

-

-

-

... More
VERTICAL PIPE

160.96

-

-

... More
TOP X-X AXIS

406.42

-

-

... More
TOP Y-Y AXIS

201.2

-

-

... More
Supply and fixing of precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

66

41976

636

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.

-

-

-

... More
Take12kg/sqm

-

-

-

23.4

-

-

2.16

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:

-

-

-

... More
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).

-

-

-

7.5

-

-

12

-

-

7.2

-

-

... More
Assuming per meter weight 2.00 kg

-

-

-

... More
Extra for polyester powder coated (minimum 50 micron) aluminium

271.8

9377

34.5

... More
sections instead of anodized.

-

-

-

... More
Providing and fixing “NETLON insect screens” with 25mm wide Hook and

-

-

-

... More
loop tape all around to wooden/ aluminium/ steel windows, ventilators and

-

-

-

... More
the like complete

-

-

-

23.4

-

-

1.62

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:

-

-

-

... More
For fixed portion

-

-

-

... More
PARTITION ROOM

41.58

-

-

18.9

-

-

... More
PASSBOX

7.56

-

-

... More
Assuming per SQ MTRweight 10.00 kg

79.38

-

-

... More
Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work on face of building. (Frame to be paid separately)

-

-

-

... More
3mm thick

-

-

-

... More
PARTITION ROOM

41.58

-

-

18.9

-

-

... More
PASSBOX

7.56

-

-

... More
Providing and fixing of floor spring IS: marked (Everite, Door link or any equivalent make) with stainless steel cover plate

12

23040

1920

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):

-

-

-

... More
With float glass panes of 6 mm thickness

-

-

-

23.4

-

-

2.16

-

-

... More
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete.

-

-

-

... More
SS Grade 204

-

-

-

... More
FOR STAIR

-

-

-

... More
NAWEL POST-88MM OD

16.54

-

-

... More
BALUSTER-33MM OD

35.64

-

-

... More
HAND RAIL-48MM OD

48.45

-

-

... More
INCLIND MEMBER-17MM OD

30.42

-

-

... More
FOR RAMP

-

-

-

... More
NAWEL POST-88MM OD

8.27

-

-

... More
BALUSTER-33MM OD

59.4

-

-

... More
HAND RAIL-48MM OD

48.45

-

-

... More
Providing and making 6mm thick cement plaster of mix:

-

-

-

... More
In Cement mortar 1:4 (1 cement : 4 fine sand)

-

-

-

... More
HEMATOLOGY BIOCHEMISTRY AREA

121.26

-

-

... More
STAFF ROOM

17.71

-

-

... More
STAIRCASE

14.07

-

-

... More
COMMON TOILET

22.47

-

-

... More
MALE TOILET

19.06

-

-

... More
FEMALE TOILET

13.39

-

-

... More
PASSAGE

31.5

-

-

... More
PATHOLOGY LAB

18.31

-

-

... More
FNAC ROOM

9.24

-

-

... More
PHLEBOTOMY ROOM1

8.09

-

-

... More
PHLEBOTOMY ROOM2

8.09

-

-

... More
PHLEBOTOMY ROOM3

8.09

-

-

... More
PASSAGE

14.1

-

-

... More
WAITING AREA

41.28

-

-

... More
CHHAJJA

11.7

-

-

7.98

-

-

... More
Providing and making 12mm thick cement plaster of mix:

-

-

-

... More
In Cement Mortar 1:5 (1 cement : 5 fine sand)

-

-

-

... More
HEMATOLOGY BIOCHEMISTRY AREA

65.8

-

-

... More
STAFF ROOM

32.2

-

-

... More
STAIRCASE

29.4

-

-

... More
COMMON TOILET

29.4

-

-

... More
MALE TOILET

25.9

-

-

... More
FEMALE TOILET

18.2

-

-

... More
PASSAGE

122.5

-

-

... More
PATHOLOGY LAB

23.1

-

-

... More
FNAC ROOM

16.8

-

-

... More
PHLEBOTOMY ROOM1

14.7

-

-

... More
PHLEBOTOMY ROOM2

14.7

-

-

... More
PHLEBOTOMY ROOM3

14.7

-

-

... More
PASSAGE

65.8

-

-

... More
WAITING AREA

22.4

-

-

... More
SEPTIC TANK

16.8

-

-

... More
TOILET

63

-

-

... More
TOILET

10.5

-

-

... More
DEDUCTION

-

-

-

23.4

-

-

2.16

-

-

15.75

-

-

25.2

-

-

15.12

-

-

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:

-

-

-

... More
In Cement Mortar 1:5 (1 cement : 5 fine sand)

-

-

-

... More
Outer plaster

-

-

-

... More
DEDUCTION

-

-

-

23.4

-

-

8.82

-

-

1.62

-

-

... More
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.

-

-

-

... More
Size above 200x300mm

-

-

-

... More
TOILET

37.8

-

-

... More
PASSAGE

11.16

-

-

... More
TOILET

7.56

-

-

... More
DEDUCTION

11.76

-

-

... More
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.

-

-

-

... More
Size 300x300mm

-

-

-

... More
TOILET BLOCK 1

31.93

-

-

... More
MALE TOILET

21.63

-

-

... More
FEMALE TOILET

13.39

-

-

... More
Providing and laying rectified ceramic glazed floor tiles of size 300x300mm and above conforming to IS : 15622 of approved make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.

-

-

-

... More
Size 300x300mm

-

-

-

... More
CONNECT TO DH

55

-

-

... More
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.

-

-

-

... More
Size 600x600mm

-

-

-

... More
HEMATOLOGY BIOCHEMISTRY AREA

121.26

-

-

... More
STAFF ROOM

17.71

-

-

... More
STAIRCASE

14.07

-

-

... More
PASSAGE

31.5

-

-

... More
PATHOLOGY LAB

18.31

-

-

... More
FNAC ROOM

9.24

-

-

... More
PHLEBOTOMY ROOM1

8.09

-

-

... More
PHLEBOTOMY ROOM2

8.09

-

-

... More
PHLEBOTOMY ROOM3

8.09

-

-

... More
PASSAGE

14.1

-

-

... More
WAITING AREA

41.28

-

-

... More
WALL TILES

-

-

-

... More
HEMATOLOGY BIOCHEMISTRY AREA

39.48

-

-

... More
PASSAGE

31.5

-

-

... More
PATHOLOGY LAB

5.94

-

-

... More
STAFF ROOM

8.28

-

-

... More
FNAC ROOM

0.72

-

-

... More
PHLEBOTOMY ROOM1

0.63

-

-

... More
PHLEBOTOMY ROOM2

0.63

-

-

... More
PHLEBOTOMY ROOM3

0.63

-

-

... More
PASSAGE

2.82

-

-

... More
WAITING AREA

5.76

-

-

... More
15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish.

-

-

-

... More
Granite stone black

-

-

-

... More
Stair Case

-

-

-

30.24

-

-

... More
WINDOW SILL

3.9

-

-

... More
DOOR SILL

3

-

-

... More
PALTFORM

16.92

-

-

... More
STAFF ROOM

6.93

-

-

... More
URIN STOOL

0.9

-

-

... More
FNAC ROOM

1.89

-

-

... More
SHOE RECK

2.21

-

-

... More
PILLAR

7.5

-

-

... More
Wall painting with acrylic premium emulsion (plastic) paint of required shade to give an even shade.

-

-

-

... More
On new work (two or more coats)

-

-

-

... More
6 MM plaster

366.33

-

-

... More
12 mm plaster

1088.07

-

-

... More
White washing with lime to give an even shade.

-

-

-

... More
6 mm plaster

366.33

-

-

... More
12 mm plaster

1088.07

-

-

... More
15 mm plaster

282.96

-

-

... More
Providing and applying 2mm thick ready mix exterior grade putty (Birla wall care, Alltek Superfine W/R of (NCL), J.K. wall putty) on walls to make the surface smooth and even.

-

-

-

... More
6 mm plaster

366.33

-

-

... More
12 mm plaster

1088.07

-

-

... More
15 mm plaster

282.96

-

-

... More
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:

-

-

-

... More
On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

-

-

-

... More
15 mm Plaster

282.96

15845

56

... More
Description

-

-

-

... More
First floor

-

-

-

... More
Columns, Pillars, Piers and likes- rectangular or square in shape

-

-

-

... More
COLUMN UP F.F. SLAB LVL

-

-

-

21.6

-

-

64.8

-

-

... More
COLUMN UP UP TO PARRAPET WALL

-

-

-

2.7

-

-

10.8

-

-

... More
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)

-

-

-

-

-

-

... More
MYCO BACTERIOLOZY/ TB LAB

15.54

-

-

... More
BACTERIOLOZY AREA

42.74

-

-

... More
CULTURE MEDIA PREPARATION LAB

15.54

-

-

... More
WASHING STERLIZATION

21.09

-

-

... More
DOFFING AREA

15.54

-

-

... More
COLD ROOM/ STORE ROOM

23.87

-

-

... More
SENIOR STAFF ROOM

29.97

-

-

... More
PASSAGE

54.54

-

-

... More
PCR ROOM

15.54

-

-

... More
EXTRACTION ROOM

11.38

-

-

... More
VIROLOZY

5.95

-

-

... More
MASTER MIX

13.91

-

-

... More
STAIRCASE

22.47

-

-

... More
ELECTRICAL ROOM

16.48

-

-

... More
DONING AREA

13.91

-

-

... More
COMMON TOILET

19.06

-

-

... More
WASTE COLLECTION

6.84

-

-

... More
Beams, lintels, cantilevers & walls

-

-

-

... More
Lintel Beam, HORIZONTAL AXIS

-

-

-

24.56

-

-

14.16

-

-

5.32

-

-

4.96

-

-

1.36

-

-

... More
Lintel Beam, VERTICAL AXIS

-

-

-

10.64

-

-

2.22

-

-

8.5

-

-

8.88

-

-

1.08

-

-

1.26

-

-

5.32

-

-

... More
Slab Beam, HORIZONTAL AXIS

-

-

-

61.4

-

-

17.7

-

-

13.3

-

-

12.4

-

-

13

-

-

28.2

-

-

4.2

-

-

6.4

-

-

... More
Slab Beam, VERTICAL AXIS

-

-

-

53.2

-

-

27.75

-

-

22.2

-

-

... More
Weather shade, chhajja, Cornices and mouldings

-

-

-

14.82

-

-

7.98

-

-

3.6

-

-

... More
Stair cases of all types excluding spiral and folded plate type, including risers and landings

-

-

-

... More
FIRST FLIGHT

9

-

-

... More
LANDING

9

-

-

... More
SECOND FLIGHT

6.75

-

-

1.35

-

-

... More
LANDING

0.67

-

-

5.4

-

-

... More
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

-

-

-

... More
COLUMN UP G.F. SLAB LVL

-

-

-

3.6

-

-

... More
COLUMN UP PARRAPET WALL

-

-

-

1.08

-

-

... More
Lintel Beam, HORIZONTAL AXIS

-

-

-

2.46

-

-

1.42

-

-

0.53

-

-

0.5

-

-

0.14

-

-

... More
Lintel Beam, VERTICAL AXIS

-

-

-

1.06

-

-

0.22

-

-

0.85

-

-

0.89

-

-

0.11

-

-

0.13

-

-

0.53

-

-

... More
Slab Beam, HORIZONTAL AXIS

-

-

-

6.14

-

-

1.77

-

-

1.33

-

-

1.24

-

-

1.3

-

-

2.82

-

-

0.42

-

-

0.64

-

-

... More
Slab Beam, VERTICAL AXIS

-

-

-

5.32

-

-

2.78

-

-

2.22

-

-

-

-

-

... More
MYCO BACTERIOLOZY/ TB LAB

0.69

-

-

... More
BACTERIOLOZY AREA

0.69

-

-

... More
CULTURE MEDIA PREPARATION LAB

0.69

-

-

... More
WASHING STERLIZATION

0.69

-

-

... More
DOFFING AREA

0.69

-

-

... More
COLD ROOM/ STORE ROOM

0.69

-

-

... More
SENIOR STAFF ROOM

0.69

-

-

... More
PASSAGE

0.23

-

-

... More
PCR ROOM

0.69

-

-

... More
EXTRACTION ROOM

0.41

-

-

... More
VIROLOZY

0.21

-

-

... More
MASTER MIX

0.64

-

-

... More
STAIRCASE

0.67

-

-

... More
ELECTRICAL ROOM

0.64

-

-

... More
DONING AREA

0.64

-

-

... More
COMMON TOILET

0.64

-

-

... More
WASTE COLLECTION

0.23

-

-

1.48

-

-

0.36

-

-

... More
FRONT CHHAJJA

0.8

-

-

... More
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

-

-

-

... More
qty same as above

67.33

6564

97.5

... More
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:

-

-

-

... More
Thermo-Mechanically treated bars FE 415

-

-

-

... More
@100kg/cum

8079.06

440308

54.5

... More
Providing and laying damp proof course (upto 50mm thick) with plain

-

-

-

... More
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed

-

-

-

... More
stone aggregate 20mm nominal size) including form work.

-

-

-

... More
PLINTH BEAM, HORIZONTAL AXIS

-

-

-

0.49

-

-

0.43

-

-

0.63

-

-

... More
VERTICAL AXIS

-

-

-

1.33

-

-

... More
Grading roof for water proofing treatment with:

-

-

-

... More
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

-

-

-

20.42

-

-

... More
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:

-

-

-

... More
Cement Mortar 1:6 (1 cement : 6 coarse sand)

-

-

-

... More
UP TO G.F. SLAB LEVEL

-

-

-

... More
Horizontal axis

36.84

-

-

... More
VERTICAL AXIS

23.94

-

-

... More
PARRAPET WALL

11.05

-

-

... More
STAIRCASE

1.66

-

-

... More
Deduction

-

-

-

-4.68

-

-

-0.32

-

-

-6.3

-

-

-1.26

-

-

-3.02

-

-

-1.76

-

-

... More
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:

-

-

-

... More
Above Quantity

118.63

14354

121

... More
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.

-

-

-

... More
40 mm. thick (single leaf)

-

-

-

5.04

-

-

23.1

-

-

... More
Providing and fixing stainless steel butt hinges IS : 12817 marked with necessary stainless steel screws etc complete.

-

-

-

... More
100x1.7mm (light)

-

-

-

8

-

-

44

-

-

... More
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete.

-

-

-

-

-

-

4

-

-

22

-

-

... More
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete.

-

-

-

... More
150 x10mm

-

-

-

8

-

-

44

-

-

... More
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete.

-

-

-

... More
100 mm

-

-

-

8

-

-

44

-

-

... More
Providing and fixing stainless steel fixed stopper with necessary stainless steel screws complete.

-

-

-

... More
100 mm long

-

-

-

4

-

-

22

-

-

... More
Providing and fixing factory made PVC door shutters of specified

-

-

-

... More
thickness made of styles and rails of a UPVC hollow section of specified

-

-

-

... More
size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on

-

-

-

... More
both sides. The styles and rails mitred and joined at the corners by means

-

-

-

... More
of M.S. galvanised/ plastic brackets of size 75x220 mm having wall

-

-

-

... More
thickness 1.0 mm and stainless steel screws

-

-

-

... More
30 mm thick door shutters with styles and rails of size 60x30 mm

-

-

-

10.08

25079

2488

... More
Providing and fixing factory made UPVC white colour casement three track three panels sliding window with fly proof s.s. wire mesh (two no. glazed & one no wire mesh panels) made of (big series) frame 116x45 mm & mesh 46x 62mm both having wall thickness of 2.3x 0.2mm and single glazing bead/ double glazing bead of appropriate dimension.(area of window above 1.75 sqm)

-

-

-

25.2

-

-

1.62

-

-

... More
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.

-

-

-

... More
channel gate 1

10.5

-

-

... More
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.

-

-

-

... More
Take12kg/sqm

-

-

-

25.2

-

-

1.08

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:

-

-

-

... More
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).

-

-

-

4.5

-

-

11

-

-

3.2

-

-

... More
Assuming per meter weight 2.00 kg

-

-

-

... More
Extra for polyester powder coated (minimum 50 micron) aluminium

205.4

7086

34.5

... More
sections instead of anodized.

-

-

-

... More
Providing and fixing “NETLON insect screens” with 25mm wide Hook and

-

-

-

... More
loop tape all around to wooden/ aluminium/ steel windows, ventilators and

-

-

-

... More
the like complete

-

-

-

23.4

-

-

1.62

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:

-

-

-

... More
For fixed portion

-

-

-

... More
PARTITION ROOM

27.72

-

-

18.9

-

-

... More
PASSBOX

7.56

-

-

... More
Assuming per SQ MTRweight 10.00 kg

65.52

-

-

... More
Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work on face of building. (Frame to be paid separately)

-

-

-

... More
3mm thick

-

-

-

... More
PARTITION ROOM

55.44

-

-

18.9

-

-

... More
PASSBOX

7.56

-

-

... More
Providing and fixing of floor spring IS: marked (Everite, Door link or any equivalent make) with stainless steel cover plate

12

23040

1920

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):

-

-

-

... More
With float glass panes of 6 mm thickness

-

-

-

23.4

-

-

2.16

-

-

... More
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete.

-

-

-

... More
SS Grade 204

-

-

-

... More
FOR STAIR

-

-

-

... More
NAWEL POST-88MM OD

16.54

-

-

... More
BALUSTER-33MM OD

35.64

-

-

... More
HAND RAIL-48MM OD

48.45

-

-

... More
INCLIND MEMBER-17MM OD

30.42

-

-

... More
FOR RAMP

-

-

-

... More
NAWEL POST-88MM OD

8.27

-

-

... More
BALUSTER-33MM OD

4.75

-

-

... More
HAND RAIL-48MM OD

12.27

-

-

... More
Providing and making 6mm thick cement plaster of mix:

-

-

-

... More
In Cement mortar 1:4 (1 cement : 4 fine sand)

-

-

-

... More
MYCO BACTERIOLOZY/ TB LAB

15.54

-

-

... More
BACTERIOLOZY AREA

42.74

-

-

... More
CULTURE MEDIA PREPARATION LAB

15.54

-

-

... More
WASHING STERLIZATION

21.09

-

-

... More
DOFFING AREA

15.54

-

-

... More
COLD ROOM/ STORE ROOM

23.87

-

-

... More
SENIOR STAFF ROOM

29.97

-

-

... More
PASSAGE

54.54

-

-

... More
PCR ROOM

15.54

-

-

... More
EXTRACTION ROOM

11.38

-

-

... More
VIROLOZY

5.95

-

-

... More
MASTER MIX

13.91

-

-

... More
STAIRCASE

22.47

-

-

... More
ELECTRICAL ROOM

16.48

-

-

... More
DONING AREA

13.91

-

-

... More
COMMON TOILET

19.06

-

-

... More
WASTE COLLECTION

6.84

-

-

14.82

-

-

3.6

-

-

... More
FRONT CHHAJJA

7.98

-

-

7.98

-

-

... More
Providing and making 12mm thick cement plaster of mix:

-

-

-

... More
In Cement Mortar 1:5 (1 cement : 5 fine sand)

-

-

-

... More
MYCO BACTERIOLOZY/ TB LAB

19.6

-

-

... More
BACTERIOLOZY AREA

53.9

-

-

... More
CULTURE MEDIA PREPARATION LAB

19.6

-

-

... More
WASHING STERLIZATION

26.6

-

-

... More
DOFFING AREA

19.6

-

-

... More
COLD ROOM/ STORE ROOM

30.1

-

-

... More
SENIOR STAFF ROOM

37.8

-

-

... More
PASSAGE

212.1

-

-

... More
PCR ROOM

19.6

-

-

... More
EXTRACTION ROOM

24.5

-

-

... More
VIROLOZY

24.5

-

-

... More
MASTER MIX

18.9

-

-

... More
STAIRCASE

29.4

-

-

... More
ELECTRICAL ROOM

22.4

-

-

... More
DONING AREA

18.9

-

-

... More
COMMON TOILET

25.9

-

-

... More
WASTE COLLECTION

26.6

-

-

... More
DEDUCTION

-

-

-

23.4

-

-

2.16

-

-

15.75

-

-

25.2

-

-

15.12

-

-

... More
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:

-

-

-

... More
In Cement Mortar 1:5 (1 cement : 5 fine sand)

-

-

-

... More
Outer plaster

-

-

-

... More
DEDUCTION

-

-

-

23.4

-

-

8.82

-

-

1.62

-

-

... More
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.

-

-

-

... More
Size above 200x300mm

-

-

-

... More
TOILET

15.12

-

-

6.66

-

-

... More
DEDUCTION

5.04

-

-

... More
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.

-

-

-

... More
Size 300x300mm

-

-

-

... More
TOILET

5.4

-

-

12.77

-

-

... More
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.

-

-

-

... More
Size 600x600mm

-

-

-

... More
MYCO BACTERIOLOZY/ TB LAB

15.54

-

-

... More
BACTERIOLOZY AREA

42.74

-

-

... More
CULTURE MEDIA PREPARATION LAB

15.54

-

-

... More
WASHING STERLIZATION

21.09

-

-

... More
DOFFING AREA

15.54

-

-

... More
COLD ROOM/ STORE ROOM

23.87

-

-

... More
SENIOR STAFF ROOM

29.97

-

-

... More
PASSAGE

54.54

-

-

... More
PCR ROOM

15.54

-

-

... More
EXTRACTION ROOM

11.38

-

-

... More
VIROLOZY

5.95

-

-

... More
MASTER MIX

13.91

-

-

... More
STAIRCASE

22.47

-

-

... More
ELECTRICAL ROOM

16.48

-

-

... More
DONING AREA

13.91

-

-

... More
COMMON TOILET

19.06

-

-

... More
WASTE COLLECTION

6.84

-

-

... More
WALL TILES

-

-

-

... More
MYCO BACTERIOLOZY/ TB LAB

5.04

-

-

... More
BACTERIOLOZY AREA

13.86

-

-

... More
CULTURE MEDIA PREPARATION LAB

5.04

-

-

... More
WASHING STERLIZATION

6.84

-

-

... More
DOFFING AREA

5.04

-

-

... More
COLD ROOM/ STORE ROOM

7.74

-

-

... More
PASSAGE

54.54

-

-

... More
PCR ROOM

5.04

-

-

... More
EXTRACTION ROOM

6.3

-

-

... More
VIROLOZY

6.3

-

-

... More
MASTER MIX

4.86

-

-

... More
STAIRCASE

7.56

-

-

... More
ELECTRICAL ROOM

5.76

-

-

... More
DONING AREA

2.43

-

-

... More
WASTE COLLECTION

6.84

-

-

... More
DEDUCTION

-11.7

-

-

... More
15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish.

-

-

-

... More
Granite stone black

-

-

-

... More
Stair Case

-

-

-

... More
STAIRCASE

10.8

-

-

... More
WINDOW SILL

3.9

-

-

... More
DOOR SILL

3

-

-

... More
PALTFORM

15

-

-

... More
PILLAR

7.5

-

-

... More
Wall painting with acrylic premium emulsion (plastic) paint of required shade to give an even shade.

-

-

-

... More
On new work (two or more coats)

-

-

-

... More
6 MM plaster

383.52

-

-

... More
12 mm plaster

1100.67

-

-

... More
White washing with lime to give an even shade.

-

-

-

... More
6 mm plaster

383.52

-

-

... More
12 mm plaster

1100.67

-

-

... More
15 mm plaster

282.96

-

-

... More
Providing and applying 2mm thick ready mix exterior grade putty (Birla wall care, Alltek Superfine W/R of (NCL), J.K. wall putty) on walls to make the surface smooth and even.

-

-

-

... More
6 mm plaster

383.52

-

-

... More
12 mm plaster

1100.67

-

-

... More
15 mm plaster

282.96

-

-

... More
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:

-

-

-

... More
On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

-

-

-

... More
15 mm Plaster

282.96

15845

56

... More
PARTICULARS OF ITEM

-

-

-

... More
BORE & PUMP

-

-

-

... More
Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tube well with in the selected habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable)

1

1502

1502

... More
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level.

-

-

-

... More
150 mm dia

160

59360

371

... More
Supplying, assembling, lowering and fixing in vertical position in bore well,ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with Ivth revision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge.

-

-

-

... More
150 mm nominal dia

55

71720

1304

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of:

-

-

-

... More
150 mm dia

1

217

217

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete

-

-

-

... More
150 mm clamp.

2

2110

1055



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.