Chhattisgarh Kamdhenu University Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Chhattisgarh Kamdhenu University - CGKV Tender

Works
Civil And Construction
Road Construction
Opening Date20 Jul 2024
Closing Date28 Aug 2024
Tender Amount₹ 1,89,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
8 metre high, minimum dia 150mm at bottom and 70mm at top

18

-

-

... More
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as required.

-

-

-

... More
Double Over Hang 1.50 metre Long

18

-

-

... More
Supplying and laying following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as required.

-

-

-

... More
4 x 25 sq. mm.

1000

-

-

... More
Supplying and laying HDPE pipe of 4kg/sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as required.

-

-

-

... More
63 mm outer dia

900

-

-

... More
Supplying and fixing metal clad busbar chamber made of 1.6 mm thick CRCA sheet with 4 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as required.

-

-

-

... More
200 amps x 450mm long

2

-

-

... More
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as required. (Only face area is to be measured)

-

-

-

... More
Upto 300 mm deep

4

-

-

... More
Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as required. (Thimbeling shall be paid separately).

-

-

-

... More
200 amps

1

-

-

... More
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
6 amps to 32 amps

45

-

-

... More
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
63 amps

4

-

-

... More
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ concealed, steel/ PVC conduit/ PVC casing caping as required.

-

-

-

... More
3 x 2.5 sq. mm

450

-

-

... More
3 x 4 sq. mm

250

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as required.

3

-

-

... More
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required.

150

-

-

... More
Supplying and fixing G.I. pipe along with wall or pole/ support with 2 Nos MS clamps for protection of under ground cable in approved manner including bolts and nuts or metal dash fasteners complete as required.

-

-

-

... More
32 mm dia

50

-

-

... More
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
3 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 25KA

2

-

-

... More
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as required.

3

-

-

... More
Providing and fixing penal mounting following rating digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as required.

-

-

-

... More
0-200 amps

1

-

-

... More
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as required.

-

-

-

... More
Digital type

1

-

-

... More
Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as required.

-

-

-

... More
For voltmeter

1

-

-

... More
For ammeter

1

-

-

... More
Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as required.

-

-

-

... More
Digital type

2

-

-

... More
Erection of GI octogonal/ tubular pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as required.

-

-

-

... More
8 metre high

18

-

-

... More
Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement (minimum 90kg per cum), form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required.

4.6

-

-

... More
Supplying erection testing and commissioning of hot dipped galvanised (single dip) 16 metre High mast pole on existing RCC foundation with all accessories and equipments, main detailed as below to withstand max wind pressure as per IS 875 Part-3: a) HM shaft made of approx weight 340 kg, sheet thickness 3 & 4 mm, nominal dia 360mm on bottom and 150 mm on top, base plate 25mm thick 520mm dia, approved no of sections (not more than 2) having suitable sectional lengths with slip joints between sections without any circumpherencial welding. b) Double drum winch with Integral single phase power tool (electrical) for lowering & raising of lantern carriage on high mast with separate handle for manual operation of winch with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) Necessary suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & rising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 6 sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I.tube having single prong. k) Anchor plate, tem-plates, GI foundation bolts min 6 Nos of 24mm dia 750 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately)

1

-

-

... More
Supplying, installation, testing and commissioning of following 230/250 volts metal halide wide beam flood light luminaries with weather proof gear box, igniter, capacitor with IP 66 protection on wall surface/ building parapet/ pole bracket complete but without lamp as required.

-

-

-

... More
1x250 watt

10

-

-

... More
Supplying, fixing, testing and commissioning of following 230/250 volts metal halide lamp in existing lighting luminaries fixed on pole/ wall/ roof etc as required.

-

-

-

... More
250 watt (T)

10

-

-

... More
Supplying, fixing, testing and commissioning of approved make following 230/250 volts polyester filled copper wound ballast in existing luminaries at all locations as required.

-

-

-

... More
For 250 watt HPSV/ Metal halide fitting

10

-

-

... More
Designing and providing suitable and approved size RCC foundation for 15-30 mere high mast including seel reinforcement (minimum 90kg per cum), form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required including laying and fixing HM foundation bolts with tam plates but excluding the cost of foundation bolts with tam plates etc complete as required.

2.5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.