Bharat Sanchar Nigam Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.
Bharat Sanchar Nigam Limited - BSNL Tender
Telecommunication Services
Eprocure
Opening Date12 Sep 2023
Closing Date23 Sep 2023
Tender Amount₹ 2,74,577
Costs
EMD
₹ 5,492Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_BSNL_167380_1Bid Award Id
ViewTender No
12/2023-24/BSNL/CD/BILASPUR Date 08.09.2023Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
All kinds of soil.
200
-
-
Clearing jungle including uprooting of rank vegatation, grass, brush wood,trees and saplings of grith up to 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
500
-
-
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
-
-
-
All kinds of soil
-
-
-
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
2
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level :
-
-
-
1 : 2 : 4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size).
1
-
-
1 : 5 : 10 (1 Cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size).
1
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
0.5
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
2
-
-
Suspended floors, roofs, landings, balconies and access platform
2
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
2
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
Thermo-Mechanically Treated bars of grade Fe-500D or more.
20
-
-
Brick work with common burnt clay F.P.S. bricks of class designation 35 in foundation and plinth in :
-
-
-
Cement mortar 1 : 4 ( 1 cement : 4 coarse sand).
1
-
-
Cement mortar 1 : 6 ( 1 cement : 6 coarse sand).
1
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
-
-
-
30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
2
-
-
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC-10 as per IS : 1868 ) transparent or dyed to required colour or shade with nuts and screws etc complete :
-
-
-
250 x 16 mm.
2
-
-
Providing and fixing aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc complete :
-
-
-
250 x 10 mm.
2
-
-
Providing and fixing aluminium handles ISI maked anodized ( anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
-
-
-
100mm
10
-
-
Structural steel work riveted, bolted or welded in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
20
-
-
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
-
-
-
Using flats 30x6mm for diagonal braces and central cross piece
6
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
2
-
-
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4Coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
2
-
-
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
-
-
-
0.63 mm thick with zinc coating not less than 275 gm/ m²
5
-
-
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
10
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion : Single socketed pipes :
-
-
-
110 mm diameter.
3
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion :
-
-
-
Bend 87.5 degree :
-
-
-
110 mm bend.
2
-
-
Shoe (plain) :
-
-
-
110 mm shoe.
2
-
-
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1 : 4 ( 1 cement : 4 coarse sand) and making good the walls etc complete :
-
-
-
110 mm.
5
-
-
12 mm cement plaster of mix :
-
-
-
1 : 6 (1 cement : 6 fine Sand ).
5
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix :
-
-
-
1:6 (1 cement: 6 fine sand)
5
-
-
6 mm cement plaster of mix :
-
-
-
1 : 3 (1 Cement : 3 fine sand).
5
-
-
Neat cement punning.
5
-
-
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters20 mm in patches of area 2.5 sq meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to dumping ground within 50 metres lead :
-
-
-
With cement mortar 1 : 4 (1 cement :4 coarse sand).
5
-
-
Renewing glass panes and refixing existing wooden fillets :
-
-
-
Float glass panes of thickness 4 mm.
1
-
-
Carriage of materials like excavted earth, moorum, excavated rocks, building rubbish, malba, sludge etc. by mechanical transport to the dumping ground including loading, unloading, stacking, spreading and levelling etc. as per requirement within municiple limits complete as per direction of Engineer in charge.
5
-
-
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-
(i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits.
(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.
(iii) Chlorination of RCC internal surface by liquid chlorine.
(iv) The treated surface shall be dried using air jetting and all loose particles shall be removed from the surface.
10000
-
-
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
5000
-
-
Removal of choakage from C.I. / HDPE pipes and fittings SW pipes etc. upto gully traps cleaning and disposal of all types of rubbish and sludge as directed by Engineer in charge.
2
-
-
Providing skilled labour for trade like plumbing / masonry / carpentry / works which are not covered and measurable in items of DSR [Note: contractor shall provide skilled labour of respective trade alonghwith necessary tools and plants].
2
-
-
Providing unskilled/casual labour, coolie / beldar for day to day maintainance work which are not covered and measurable in items of DSR.
2
-
-
Demolishing cement concrete & CC Flooring manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
-
-
-
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
1
-
-
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
-
-
-
In cement mortar
1
-
-
Demolishing R.C.C. work ( like Chajja, Beam, R.C.C. walls, R.C.C. Fins & Slab at all Height ) manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
1
-
-
Repairs to wooden / aluminium doors, windows etc. including dismantling and refixing the same with screws, or by welding if required hinges, etc. doing all the operation complete as per direction of Engineer in charge. [Note: New Section, new hinges, fittings etc. if required will be paid for separately].
5
-
-
Providing and fixing wash basin with C.I. brackets, including painting of fittings and brackets, cutting and making good the walls wherever required.
-
-
-
White Vitreous China Flat back wash basin size 550x400 mm.
1
-
-
Providing and fixing white vitreous china water closet squatting pan (Indian type) :
-
-
-
Orissa pattern W.C. pan of size 580x440 mm including necessary PVC P or S trap required at site.
1
-
-
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fitures complete :
-
-
-
10 Litre capacity - white.
1
-
-
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete :
-
-
-
Semi rigid pipe :
-
-
-
32 mm dia.
5
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
-
-
-
15 mm nominal outer dia. Pipes.
2
-
-
20 mm nominal outer dia. Pipes.
2
-
-
25 mm nominal outer dia .Pipes.
2
-
-
40 mm nominal outer dia. Pipes.
2
-
-
50 mm nominal outer dia. Pipes.
2
-
-
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall :
-
-
-
15 mm dia nominal bore.
2
-
-
20 mm dia nominal bore.
2
-
-
25 mm dia nominal bore.
2
-
-
40 mm dia nominal bore.
2
-
-
50 mm dia. nominal bore
2
-
-
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work
-
-
-
40 mm dia. nominal bore
5
-
-
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
-
-
-
25 to 40 mm nominal bore
1
-
-
Providing and fixing unplasticised PVC connection pipe with brass unions :
-
-
-
30 cm length :
-
-
-
15 mm nominal bore.
3
-
-
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :
-
-
-
15 mm nominal bore.
1
-
-
20 mm nominal bore.
1
-
-
25 mm nominal bore.
1
-
-
40 mm nominal bore.
1
-
-
50mm nominal bore
1
-
-
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
500
-
-
Providing and fixing PTMT bib cock of approved quality and colour.
-
-
-
15mm nominal bore, 86 mm long, weighing not less than 88 gms.
5
-
-
Providing and fixing PTMT stop cock of approved quality and colour.
-
-
-
15 mm nominal bore, 86 mm long, weighing not less than 88 gms.
5
-
-
Grading roof for water proofing treatment with
-
-
-
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
1
-
-
Providing and fixing C.P. brass Pillar cock 15 mm nominal bore of standard design and of approved make conforming to IS specification.
3
-
-
Providing and fixing HDPE tank cover with suitable locking arrangement complete as per direction of Engineer in charge.
3
-
-
Providing and fixing brass half turn gate valve with M.S. handle of ZOLOTO or equivalent make as approved by the Engineer in charge and as per manufacturer specification:
-
-
-
15 mm nominal bore.
1
-
-
20 mm nominal bore.
1
-
-
25 mm nominal bore.
1
-
-
40 mm nominal bore.
1
-
-
50 mm nominal bore.
1
-
-
Providing and fixing PTMT Ball cock of approved quality,colour and make complete with Epoxy coated aluminium rod with L.P. / H.P.H.D. plastic ball.
-
-
-
15 mm nominal bore, 105 mm long.
1
-
-
25 mm nominal bore, 152 mm long.
1
-
-
Providing laying and jointing PVC SWR Type "B" soil waste and vent pipes conforming to IS 13592:2013, including jointing with seal ring conforming to IS: 14735:1999, including jointing the pipes with appropriate adhessive as per the manufacturers specifications and testing of joints etc. complete.
-
-
-
160 mm diameter pipes
5
-
-
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
-
-
-
150 mm nominal
5
-
-
Providing and fixing Standard CP Brass Waste Coupling to Wash Basins/Urinals of required size etc. complete as directed by the Engineer-in-Charge.
1
-
-
Dismantling vitreous china Wash Basins / Urinal Pots of any size including dismantling waste pipes, brackets and stacking the serviceable material to the place as directed by the Engineer – in – Charge.
1
-
-
Removing and Refixing PVC/CI Floor Traps of any size including connecting the existing waste pipes and outlet pipes to the traps etc. complete as directed by the Engineer – in – Charge:
1
-
-
Providing & fixing 0.50 mm thick Aluminium sheet to toilet door shutters including cutting & folding in required size and shape with necessary screws, nuts etc including removing & refixing the shutter as per direction of Engineer-in-charge
2
-
-
Removing of G I pipes (Internal work)including removing clamping and stacking at required place as directed by Engineer-in-charge.
-
-
-
a) 15 mm to 50 mm dia G.I.Pipe
5
-
-
Refixing of G I pipes (Internal work) including clamping and fixing as directed by Eng-in-charge.
-
-
-
a) 15 mm to 50 mm dia G.I.Pipe
5
-
-
Providing and fixing metallic FLUSH COCK of approved make etc. complete as directed by the Engineer -in-Charge:
-
-
-
(a) 25 mm diameter nominal bore
1
-
-
Providing and fixing G.I. tank nipples and washers for preventing leakage of tank, cutting and threading the pipe and making long screws and fixing of tank nipples in PVC tank with M-SEAL etc. complete wherever required and as per direction of Engineer in charge :
1
-
-
Cleaning of manhole and removing all types of rubbish and sludge with propper rodding to the next manhole and cleaning the sewer line between two manholes and disposal of all types of rubbish and sludge as required and as directed by the Engineer in charge.
20
-
-
Providing and fixing G.I. pipe fittings in existing G.I. pipe line like nipple, elbow, tee, sockets, reducers etc. as per the direction of Engineer in charge.
-
-
-
15 mm to 40 mm nominal bore.
20
-
-
Supplying of welding machine along with operator and assistance for different type of welding work
2
-
-
Providing and fixing double scaffolding system (with bamboo) on the exterior side, up to seven story height made with 40 mm dia Bamboo 1.5 m centre to centre, horizontal & vertical bamboo joining with Coconut Rassi, challies, Bamboo staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
50
-
-
Cleaning of terrace including cleaning of outlet for rain water, chhajja and disposal of rubbish, malba out side of compound and removal of unwanted plant, vegetation from compound wall etc. all complete as per direction of Engineer-in-charge.
-
-
-
Terrace of T.E. Building / M/W Building/ DTO Bldg., i/c Chowkidar hut etc. , including wall around.
6000
-
-