State Agricultural Marketing Board Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.
State Agricultural Marketing Board Tender
Electrical and Electronics
Electrical Works
Opening Date4 Aug 2021
Closing Date13 Aug 2021
Tender AmountRefer Documents
Costs
EMD
₹ 2,93,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
80907Bid Award Id
ViewTender No
80907Tender Authority
State Agricultural Marketing Board ViewPurchaser Address
-Website
http://www.cg.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
SITC of total 370 HP VRV/F Outdoor Units as per site requirment with Lifting,Shifting , Supply, Instalaltion, testing and commissioning of Modular type outdoor units equipped with highly energy efficient Scroll Compressors with all inverter compressor(s), tensile strength of compressor body not less than 600 MPa, each outdoor unit have external static pressure not less than 65 Pa, special designed four faces heat exchanger, ODU dB level less than 65 at a distance 1 Meter, centrifugal fan for condenser, ODU having front suction & top discharge, refnet / Y-branch as required, outdoor unit support, auto check function for connection error, auto address setting, refrigerant cooled PCB circuit at ODU and capacity as mentioned below. VRF System shall be suitable for working on 46 deg C ambient temperature, Refrigerant R410 A 28 HP (14 HP + 14 HP) (Modal No……………………………….)
3
-
-
... More
SITC of total 370 HP VRV/F Outdoor Units as per site requirment with Lifting,Shifting , Supply, Instalaltion, testing and commissioning of Modular type outdoor units equipped with highly energy efficient Scroll Compressors with all inverter compressor(s), tensile strength of compressor body not less than 600 MPa, each outdoor unit have external static pressure not less than 65 Pa, special designed four faces heat exchanger, ODU dB level less than 65 at a distance 1 Meter, centrifugal fan for condenser, ODU having front suction & top discharge, refnet / Y-branch as required, outdoor unit support, auto check function for connection error, auto address setting, refrigerant cooled PCB circuit at ODU and capacity as mentioned below. VRF System shall be suitable for working on 46 deg;C ambient temperature, Refrigerant R410 A 26 HP (14 HP + 12 HP) (Modal No……………………………….)
1
-
-
... More
SITC of total 370 HP VRV/F Outdoor Units as per site requirment with Lifting,Shifting , Supply, Instalaltion, testing and commissioning of Modular type outdoor units equipped with highly energy efficient Scroll Compressors with all inverter compressor(s), tensile strength of compressor body not less than 600 MPa, each outdoor unit have external static pressure not less than 65 Pa, special designed four faces heat exchanger, ODU dB level less than 65 at a distance 1 Meter, centrifugal fan for condenser, ODU having front suction & top discharge, refnet / Y-branch as required, outdoor unit support, auto check function for connection error, auto address setting, refrigerant cooled PCB circuit at ODU and capacity as mentioned below. VRF System shall be suitable for working on 46 deg C ambient temperature, Refrigerant R410 A 24 HP (12 HP + 12 HP) (Modal No……………………………….)
1
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required. - Ceiling mounted Ductable/Ceiling suspended Unit (CSU) type units 8.15 TR high Static Ductable (Modal No……………………………….)
3
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required.Ceiling mounted Ductable/Ceiling suspended Unit (CSU) type units - 6.50 TR high Static Ductable (Modal No……………………………….)
14
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required.Ceiling mounted Ductable/Ceiling suspended Unit (CSU) type units - 4.75 TR Mid Static Ductable (Modal No……………………………….)
5
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required.Ceiling mounted Ductable/Ceiling suspended Unit (CSU) type units - 4.10 TR Mid Static Ductable (Modal No……………………………….)
3
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required.Ceiling mounted Ductable/Ceiling suspended Unit (CSU) type units - 4.10 TR Mid Static FCU (Modal No……………………………….)
6
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required.Ceiling mounted Ductable/Ceiling suspended Unit (CSU) type units - 2.65 TR Mid Static FCU (Modal No……………………………….)
1
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as requiredWall Mounted Hi-wall (Split) type units (with cordless remote) - 2.10 TR (Modal No……………………………….)
8
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required - Wall Mounted Hi-wall (Split) type units (with cordless remote) - 1.65 TR (Modal No……………………………….)
16
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required - Wall Mounted Hi-wall (Split) type units (with cordless remote) - 1.30 TR (Modal No……………………………….)
3
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required - Wall Mounted Hi-wall (Split) type units (with cordless remote) - 1.10 TR (Modal No……………………………….)
1
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required. - 4 way Cassette type units (with cordless remote) - 4.10 TR (Modal No……………………………….)
2
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required. - 4 way Cassette type units (with cordless remote) - 3.10 TR (Modal No……………………………….)
14
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required. - 4 way Cassette type units (with cordless remote) - 2.65 TR (Modal No……………………………….)
3
-
-
... More
SITC of indoor Units shall be either ceiling mounted ductable type, Slim ductable (FCU) Type,Ceiling suspended Unit (CSU), Cassette type or Hi wall split (With extranal drain pump)type as specified. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate respond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be Hydraulically or mechanically expanded and tested for 21Kg/cm2. Indoor units shall have fittings, filter, drain pump in Cassette unit, Panel, required cable to connect indoor unit to socket, wireless / Wired remote control as per specified, all accessories, Vibration isolators & supports etc. Complete as required. - Remote control Digital Display Corded (Wired) remote controllers with 8 to 10 mtr control cable For Ductable Unit & FCU
34
-
-
... More
Intelligent i-Touch Central Remote Controller Unit with necessary control cabling for VRF control with BMS compatablity for all indoor & outdoor controls With Time Schedule & fault diagnosis of entire system.
1
-
-
... More
Refrigerant Y-joints - Supply of factory insulated Pair of Refrigerant T-joints for various pipe sizes and headers For Outdoor units
9
-
-
... More
Refrigerant Y-joints - Supply of factory insulated Pair of Refrigerant Y-joints for various pipe sizes and headers for Indoor units
72
-
-
... More
Metal Duct Work - G.I. Sheet Metal Duct Work As Per IS-655 Ducting Standards Factory Fabrication
Supply, fabrication, installation and testing of sheet metal ducts of 20 gauge Ducting ( rectangular ) thickness including necessary supports, hangers, nut & bolts, gaskets, splitter dampers, vanes Double Canvass Connections, Fresh Air Intakes, Cowl with bird sceens also Air balancing / Air Adjustment as per design requirements etc. complete as per specifications in accordance with the approved shop drawing. As Per IS-655 Ducting Standards
480
-
-
... More
Supply, installation, testing and balancing of extruded powder coated aluminium linear grills as per approved shop drawings & approved samples. Return air aluminium continuous grilles without damper.
52
-
-
... More
Supply, installation, testing and balancing of extruded powder coated aluminium linear grills as per approved shop drawings & approved samples. Supply/ Return air extruded Al. box tpe damper.
34
-
-
... More
Supply, installation, testing and balancing of extruded powder coated aluminium linear grills as per approved shop drawings & approved samples. Supply/Return air aluminium continuous Curved grilles without damper
54
-
-
... More
Square Exhaust Air Grilles
Supply, installation & testing of exhaust air grilles . All grilles shall be single louvered only Aluminium powder coated grilles
3
-
-
... More
ACOUSTIC LINING (DUCTS)
Supply, installation & testing of acoustic lining within S.A. Plenum & initial 3 RMT of duct nd return air ducts as per specifications. All ducts shown cross hatched on the approved shop drawings shall be provided with acoustic lining of thermal insulation. Boards, covered with perforated aluminium sheet, nuts, bolts etc. complete as per specifications and drawings. 15 mm thick resin bonded fiberglass rigid board density not less than 48 Kg/ M3 density covered with R.P. Tissue paper & 24 G perforated aluminium sheets having 3mm perforations at 6mm centers.
112
-
-
... More
THERMAL INSULATION
Supply, installation & testing of thermal insulation on ducts, as per the specifications & approved shop drawings.
Thermal insulation for indoor ducts 13 MM THICK XLPE WITH ONE SIDE FACTORY LAMINATED ALUMINIUM
2460
-
-
... More
COMMUNICATION CABLE 0 .75SQMM X 2 CORE
1875
-
-
... More
M.S. Structure for installing VRV/DX outdoor units duly epoxy coated/galvanised
20
-
-
... More
Refrigerant copper piping as per specification 41.1 MM
30
-
-
... More
Refrigerant copper piping as per specification 34.9 MM
50
-
-
... More
Refrigerant copper piping as per specification 28.6 MM
100
-
-
... More
Refrigerant copper piping as per specification 19.1 MM
240
-
-
... More
Refrigerant copper piping as per specification 15.9 MM
200
-
-
... More
Refrigerant copper piping as per specification 12.7 MM
250
-
-
... More
Refrigerant copper piping as per specification 9.5 MM
250
-
-
... More
Refrigerant copper piping as per specification 6.4 MM
100
-
-
... More
Supply, filling, Testing & Commissioning charges along with topping-up of refrigerant for VRV/VRF / DX System. R-410A
300
-
-
... More
Supplying, laying, fixing, testing of Rigid PVC Pipes pipes of 6 kg/sqcm, duly insulated with 6 mm Thick Nirtile rubber pipe section, complete with all necessary fittings such as elbows, tees, reducers, serviceable 'P' traps. etc and supports such as clamps etc complete as per specifications - 40MM
262
-
-
... More
Supplying, laying, fixing, testing of Rigid PVC Pipes pipes of 6 kg/sqcm, duly insulated with 6 mm Thick Nirtile rubber pipe section, complete with all necessary fittings such as elbows, tees, reducers, serviceable 'P' traps. etc and supports such as clamps etc complete as per specifications - 32MM
150
-
-
... More
Supplying, laying, fixing, testing of Rigid PVC Pipes pipes of 6 kg/sqcm, duly insulated with 6 mm Thick Nirtile rubber pipe section, complete with all necessary fittings such as elbows, tees, reducers, serviceable 'P' traps. etc and supports such as clamps etc complete as per specifications - 25MM
225
-
-
... More
Double Canvass connection for AHUs / FCUs with provision for temp. / air measurment at outlet.
35
-
-
... More
Exposed Area Under deck Insulation With 25 mm Thk “PIR'” POLYISOCYANAURATE slabs having aluminium face surface (CLASS O, Density 45Kg/M3, Thermal Conductivity 0.023 W/m K), Washers, G.I. Crossed Binding Wires, Joints sealed with Self adhesive aluminium tape As per specification
900
-
-
... More
G.I. Sheet Metal Duct Work As Per IS-655 Ducting Standards on Factory Fabrication.Supply, fabrication, installation and testing of sheet metal ducts of 24 gauge Ducting (rectangular) thickness including necessary supports, hangers, nut & bolts, gaskets, splitter dampers, vanes Double Canvass Connections, Fresh Air Intakes, Cowl with bird sceens also Air balancing / Air Adjustment as per design requirements etc. complete as per specifications in accordance with the approved shop drawing. As Per IS-655 Ducting Standards.
1170
-
-
... More
G.I. Sheet Metal Duct Work As Per IS-655 Ducting Standards on Factory Fabrication.Supply, fabrication, installation and testing of sheet metal ducts of 20 gauge Ducting (rectangular) thickness including necessary supports, hangers, nut & bolts, gaskets, splitter dampers, vanes Double Canvass Connections, Fresh Air Intakes, Cowl with bird sceens also Air balancing / Air Adjustment as per design requirements etc. complete as per specifications in accordance with the approved shop drawing. As Per IS-655 Ducting Standards.
1080
-
-
... More
Supplying, installation, testing and commissioning of following
sizes heavy duty (continuous running) 1400 rpm exhaust fan in
existing opening in wall including earthing etc. complete as
required. 28800 CFM / 900 MM SWEEP (EXHAUST AIR AXIAL FAN)
2
-
-
... More
Supplying, installation, testing and commissioning of following
sizes heavy duty (continuous running) 1400 rpm exhaust fan in
existing opening in wall including earthing etc. complete as
required. 28800 CFM / 900 MM SWEEP (FRESH AIR AXIAL FAN)
2
-
-
... More
SINGLE STAGE EVAPORATIVE COOLING UNIT with Double skin Panel with 43mm thk. PUF insulated Panel Skin of 22/22 G with Fan, Filters, Cooling Meadia, Water Pumps, etc as per Specifications - 12000 CFM / 50 MM SP
1
-
-
... More
Supply, installation, testing and commissioning of duct mounted air purification system/ cell based on advanced oxidation technology with broad spectrum UV lamp (100-380 NM) enhanced on the quad metallic compound target/ hydrated catalytic matrix cell with the capability to produce friendly oxidizers like Ionized Hydro Peroxides, Super Oxide Ions, Hydroxides Ions and duly enclosed by a poly casing tube that should prevent glass or mercury leakage into the conditioned/ served space. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required vis-à-vis the wattage of the units. The system shall be capable of reducing microbial, viral and spores contamination and VoC’ and odors. The UV lamp must be enclosed in a poly casing to prevent mercury at all cost. PHIO 25
29
-
-
... More
SITC In-line Centrifugal Duct fan Inline fans shall be complete with centrifugal impeller, casing, direct driven motor, vibration isolators and with fan assembly. Housing shall be constructed of hot rolled GSS sheet metal construction. Fan wheel shall be forward/backward curved type, fan wheel shall be statically and dynamically balanced.
250 CFM to 1500CFM/12-15MM ST-PR for Room Fresh Air & Guest Rm Toilet Exhaust - 600 CFM / 15 MM SP (Exhaust Air Fan)
8
-
-
... More
SITC In-line Centrifugal Duct fan Inline fans shall be complete with centrifugal impeller, casing, direct driven motor, vibration isolators and with fan assembly. Housing shall be constructed of hot rolled GSS sheet metal construction. Fan wheel shall be forward/backward curved type, fan wheel shall be statically and dynamically balanced.
250 CFM to 1500CFM/12-15MM ST-PR for Room Fresh Air & Guest Rm Toilet Exhaust - 600 CFM / 15 MM SP (Fresh Air Fan)
7
-
-
... More
SITC In-line Centrifugal Duct fan Inline fans shall be complete with centrifugal impeller, casing, direct driven motor, vibration isolators and with fan assembly. Housing shall be constructed of hot rolled GSS sheet metal construction. Fan wheel shall be forward/backward curved type, fan wheel shall be statically and dynamically balanced.
250 CFM to 1500CFM/12-15MM ST-PR for Room Fresh Air & Guest Rm Toilet Exhaust - 300 CFM / 12 MM SP (Exhaust Air Fan)
8
-
-
... More
SITC In-line Centrifugal Duct fan Inline fans shall be complete with centrifugal impeller, casing, direct driven motor, vibration isolators and with fan assembly. Housing shall be constructed of hot rolled GSS sheet metal construction. Fan wheel shall be forward/backward curved type, fan wheel shall be statically and dynamically balanced.
250 CFM to 1500CFM/12-15MM ST-PR for Room Fresh Air & Guest Rm Toilet Exhaust - 250 CFM / 12 MM SP (Exhaust Air Fan)
2
-
-
... More
SITC In-line Centrifugal Duct fan Inline fans shall be complete with centrifugal impeller, casing, direct driven motor, vibration isolators and with fan assembly. Housing shall be constructed of hot rolled GSS sheet metal construction. Fan wheel shall be forward/backward curved type, fan wheel shall be statically and dynamically balanced.
250 CFM to 1500CFM/12-15MM ST-PR for Room Fresh Air & Guest Rm Toilet Exhaust - 200 CFM / 12 MM SP (Exhaust Air Fan)
1
-
-
... More
SITC In-line Centrifugal Duct fan Inline fans shall be complete with centrifugal impeller, casing, direct driven motor, vibration isolators and with fan assembly. Housing shall be constructed of hot rolled GSS sheet metal construction. Fan wheel shall be forward/backward curved type, fan wheel shall be statically and dynamically balanced.
250 CFM to 1500CFM/12-15MM ST-PR for Room Fresh Air & Guest Rm Toilet Exhaust - 100 CFM / 12 MM SP (Exhaust Air Fan)
2
-
-
... More
FIRE ALARM SYSTEM - Supply, installation, testing & commissioning of Networkable Intelligent Addressable Fire Alarm Control Panel (EN/UL Approved) having provision of 10 loops but with following no of loop cards, each loop capable of connecting upto 99 detector and 99 devices, with minimum 200 character LCD display, multiple access levels, event history file in non-volatile memory (EEPROM) to store 20000 events, including Loop driver cards, network card, in-built battery backup for 72 hrs in standby mode & 30 min in alarm condition mode in metal enclosure and other required accessories.
1
-
-
... More
Supply, Installation, Testing and Commissioning of Work station with PC with Printer and with GUI based network software (License FOR 250 devices) capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various sensors locations or device locations with Required communication Network modules to Run the GUI based Building Integrator.
1
-
-
... More
Supply, installation, testing & commissioning of follwing type Addressable detectors (EN/UL approved) with detector mounting base and other required accessories. Photoelectric type Smoke detectors
445
-
-
... More
Supply, installation, testing & commissioning of follwing type Addressable detectors (EN/UL approved) with detector mounting base and other required accessories. Photoelectric type Smoke detectors Rate of Rise Thermal (Heat) detectors
138
-
-
... More
Supply, installation, testing & commissioning of follwing Addressable devices (EN/UL approved) with mounting base and other required accessories.Addressable Type Manual Call Points.
25
-
-
... More
Supply, installation, testing & commissioning of follwing Addressable devices (EN/UL approved) with mounting base and other required accessories. Isolator module (Fault / Loop)
25
-
-
... More
Supply, installation, testing & commissioning of follwing Addressable devices (EN/UL approved) with mounting base and other required accessories.Monitor Module
4
-
-
... More
Supply, installation, testing & commissioning of follwing Addressable devices (EN/UL approved) with mounting base and other required accessories.Control Module (for access triping off)
25
-
-
... More
Supply, installation, testing & commissioning of follwing Addressable devices (EN/UL approved) with mounting base and other required accessories.Response indicator
220
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 7mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes. 80 mm dia
150
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 7mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes. 150 mm dia
280
-
-
... More
Supplying and installing cast iron dual plate wafer type PN1.6 double flanged type non-return valve including nuts, bolts, 1.5mm thick compressed asbestos gasket including matching flanges complete. 80 mm dia
2
-
-
... More
Supplying and installing cast iron dual plate wafer type PN1.6 double flanged type non-return valve including nuts, bolts, 1.5mm thick compressed asbestos gasket including matching flanges complete. 150 mm dia
4
-
-
... More
Supplying and installing cast Iron Butterfly Valves complete with flanges on both sides including flanges on receiving pipe with nuts, bolts, 1.5mm thick compressed asbestos gasket insertion as required. PN 1.6 80 mm dia
17
-
-
... More
Supplying and installing cast Iron Butterfly Valves complete with flanges on both sides including flanges on receiving pipe with nuts, bolts, 1.5mm thick compressed asbestos gasket insertion as required. PN 1.6 150 mm dia
30
-
-
... More
Providing and fixing ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20kg/sq.cm of approved quality as specified. 25 mm dia
35
-
-
... More
Providing and fixing single acting air release valve with screwed inlet 25mm dia.
7
-
-
... More
Providing and fixing pressure switch with suitable for 1-10 Kg/cm2 including 12/15 mm diameter isolation valve, G.I. nipple, elbow, electrical connections setting of Cut-In and cut-Off pressure complete in all respects and in an approved manner.
3
-
-
... More
Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydrant station. Dial diameter 100mm calebration 0-10kg/sq.cm
35
-
-
... More
First aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia & 30meter long high pressure hose to IS- 5132 with 5mm outlet nozzle with shut off valve drum and suitable bracket etc as required conforming to IS:884.
24
-
-
... More
Single headed hydrant comprising of SS.landing valve conforming to IS:5290 with instataneous female coupling on the outlet with S.S orifice flange 6mm thick as required to maintain 3.5kg/sq.cm blank cap and chain, necessary companion flanges (as per table 'E' nuts,bolts, washers and gasket complete.
30
-
-
... More
63mm dia x 15m long reinforced rubberized fabric lined hose including SS male & female instantaneous type coupling, machine wound with wire complete in all respects. Hose shall conform to IS:636 type-II and coupling to IS:903.
60
-
-
... More
Standard short size SS branch pipe with SS nozzle 16mm dia outlet with standard instantaneouts type 63mm dia coupling.
30
-
-
... More
Supplying and installing Y strainer 150 mm dia complete with flanges with nuts, bolts, 1.5mm thick compressed asbestos gasket insertion as required.
2
-
-
... More
Standard Fire Man's Axe with heavy insulated rubber handle tested to 20000 Volts as per IS:929 complete.
24
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 7mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes complete. Pipes upto 50mm dia threaded joints with holdite, 65mm and above should be welded joint. 50 mm dia
70
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 7mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes complete. Pipes upto 50mm dia threaded joints with holdite, 65mm and above should be welded joint. 65 mm dia
130
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 7mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes complete. Pipes upto 50mm dia threaded joints with holdite, 65mm and above should be welded joint. 80 mm dia
80
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 7mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes complete. Pipes upto 50mm dia threaded joints with holdite, 65mm and above should be welded joint. 150 mm dia
795
-
-
... More
Providing and fixing 15mm gun metal sprinkler head with quartzoid bulb and set to operate at specified temperature pendent/upright/side wall as per the location indicated on the drawings. Sprinklers 68degree C FOC/UL/FM approved complete with socket nipple, adaptor etc. sprinkler shall be pendant type. Pendent type in brass chrome finish.
770
-
-
... More
Providing and fixing 15mm gunmetal sprinkler head with quartzoid bulb and set to operate at specified temperature pendent/upright/side wall as per the location indicated on the drawings. Sprinklers 68degree C FOC/UL/FM approved complete with socket nipple, adaptor etc. sprinkler shall be pendant type. Side Wall in brass/chrome finish
15
-
-
... More
Providing and fixing 25mm dia gunmetal inspecting & testing assembly with ball valves(3Nos) gunmetal sight glass, bye pass valve & connected to drain line.
10
-
-
... More
Providing and fixing M.S. cabinet fabricated from 16 gauge M.S. Sheet with full front plate glass door and locking arrangements for pad lock with suitable shelves for keeping 50 spare sprinklers and one spanner properly fixed in the shelves and cabinet painted fire red with stove enamel of approved shade size 750 x 600 x 250mm including the cost of 50nos spare sprinklers (5 nos side wall, 45nos pendent) spaner set and 2 rolls of locatite.
6
-
-
... More
Providing and fixing elelctrically operated flow indicating switches model system sensor in sprinkler branch line on each floor with necessary junction box installed in accessible place (Wiring from switches to panel and staircase pressurisation not included)
14
-
-
... More
Providing & Fixing Annuniciatior Panel for flow control switches, providing Audio/Visual indications of activation of Automation Sprinkler system for eah zone complete as per specification.
1
-
-
... More
Providing & Fixing Solid copper / aluminium conductor, PVC insulated ISI marked control cable from individual flow switch on each floor to ammunication panel intalled in for control room including sleeves, cable clips, supports for horizontal runs. 2 x 1.5 mm2
500
-
-
... More
Providing and fixing 150mm installation control valve assembly with turbine type automatic alarm to be conencted with control valve, drain valve, test valve and piping as per manufacturer 's specifications complete in all respects.
1
-
-
... More
Supply , Installation , Testing & Commissioning of Flexible Hose for Sprinklers points. 1000mm long, complete as per standard.
445
-
-
... More
Addressable Loop Sounder / Hooter with all other accessories required to complete the job.
25
-
-
... More
Addressable Relay control module with all other accessories required to complete the job.
4
-
-
... More
Supply and laying of 2C x 1.5 Sqmm FRLS cable.
6500
-
-
... More
Supplying, installing, testing, & commissioning of diesel engine driven Standby Pump suitable for automatic operation consisting of the following ( as per specification ). Horizontal end suction centrifugal suction type pump complete for delivery of 2280 ltrs./minute against a total head of 60 metres with bronze impeller complete with Mechanical Seal. Water cooled Diesel Engine developing 60 BHP ( or as per Pump Efficiency ) for the above pump at 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump, RCC Foundation and vibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically with a unit of battery of Lead Acid 24V, 150 Ah, and battery charger as per specifications. ( contd ) Rate shall also include of day oil tank of 100 lts capacity with first charge, suitable reinforced cement concrete pump foundation of 1:2:4 ratio ( 1 cement : 2 fine aggregate : 4 coarse aggregate ) including foundation bolts, washers as required. Fuel Tank shall be of 2 mm thick sheet, factory made, and shall have indications for Low Fuel.Suitable mechanical seal with mounting arrangement. 1no pressure gauge on the delivery line with isolation cock. Coupling & coupling guard for direct coupling of engine & pump. Drain pipe with valve (25mm dia) . 24volts lead acid battery (12volts) with boost/trickle charger for starting the engine automatically complete as per requirement.
1
-
-
... More
Supplying, installing, testing, & commissioning of electric driven Main Pump suitable for automatic operation consisting of the following (as per specification). Horizontal single stage end suction centrifugal suction type pump complete for delivery of 2280 ltrs./minute against a total head of 60 metres with bronze impeller complete with Mechanical Seal. Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of 50 HP ( or as per pump efficiency ) rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type such as confirming to IP:55 and flexible coupling and coupling guard with the pump. Motor shall accept +/- 10% variation in voltage and +/- 3 % variation in frequency. Common bed plate of fabricated mild steel. 1No pressure guage on delivery line with isolation cock. Suitable mechanical seal with mounting arrangement. Coupling & coupling guard for direct coupling of pump & motor. Drain pipe with valve (25mm dia)
1
-
-
... More
Supplying, installing, testing, & commissioning of electric driven automatic pressurisation pump set consisting of the following. Horizontally mounted centrifugal end suction type Jockey pump complete for delivery of 180 ltrs./minute against a total head of 60 metres with bronze impeller complete with Mechanical Seal. Squirrel cage induction motor suitable for 415 V, 50Hz, AC supply of 12.5 HP ( or as per pump efficiency ) rating for the above pump with synchronous speed of 2900 RPM T.E.F.C type such as confirming to IP:55 and flexible coupling and coupling guard with the pump. Motor shall accept +/- 10% variation in voltage and +/- 3 % variation in frequency. Common bed plate of fabricated mild steel. Suitable mechanical seal & 1No pressure guage on delivery line with isolation cock. Suitable pressure vessel (minimum 450mm dia & 2000mm height fabricated from M.S shet with shell thicknes 12mm and dish ends 10mm with all fittings/ accessories such as air release valve, drain valves etc), two coats of red enamel paint over primer outside and two costs of epoxy coating inside, 1no pressure gauge on the delivery line. Drain pipe with valve (25mm dia)
1
-
-
... More
Supply instalation testing and commissioning of fire pump panel complete as per standared manufacture and fire norms complete is all respect suitable for above mention fire pump.
1
-
-
... More
Body earthing of the various equipments/ motors/ switchgears supplied by the bidder with suitable size of earthing strip/wire etc. as per IS:3043 and as required.
1
-
-
... More
Providing and fixing Exhaust for diesel enginedriven pump consisting of M.S.Pipe 150mm dia including all fittings like flanges, bends, tees reducers etc, clamps/structural steel supports. The pipe shall be provided with 75mm thick fibreglass insulation & covering the insulation with 500g polythene sheet giving proper overlaps & sealing the joints with suitable adhesive compound. The pipe shall be provided with 21 gauge aluminium sheet clading.
1
-
-
... More
Providing and fixing resilient rubber lined neoprene single arch vibration eliminaors with unit control suitable for fire pump upto 45deg C. Temperature working pressure 20kg per sq. cm 80mm dia
30
-
-
... More
Providing and fixing resilient rubber lined neoprene single arch vibration eliminaors with unit control suitable for fire pump upto 45deg C. Temperature working pressure 20kg per sq. cm 80mm dia 150mm dia
2
-
-
... More
Providing and fixing 6mm thick orifice plate of brass with central hole of required dia of pipe as per TAC densing having a projected identification tag duly marked with K factor complete in all respects. 80mm dia
4
-
-
... More
Supplying, installation, testing & commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, dripand drain valve with water motor gong complete as required 80 mm dia
30
-
-
... More
Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as perdesignconsideration complete as required.
1
-
-
... More
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solenoid valve, weather proof operation on 24 volts DC supply complete as required.
52
-
-
... More
Supplying and fixing 4 way Fire Brigade Connection of cast iron body with 4 Nos. Gun metal male instantaneous inlet couplings complete with cap and chain conforming to IS: 904 including connection to existing MS pipe line complete as required.
1
-
-
... More
Providing and fixing CO2 type fire extinguishers with steel cylinder with a discharge valve and conforming to IS:15683. Extinguishers shall be painted with rex enamel paint and fixed to wall with brackets capacity 4.5 Kg.
1
-
-
... More
Providing and fixing ABC powder type fire extinguisher suitable for inverted operation and fabricated from 1.6 mm M.S. sheet internally protected with anticorrosive treatment and hydraulically tested to a pressure of 25 Kg/Sqcm. Extinguishers externally painted with red enamel and fixed to wall with brackets complete with internal charge and spanner (Conforming to IS:15683 capaicity 6 Kg.).
26
-
-
... More
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube,high pressure discharge hose,discharge nozzle, ISI marked as per IS:2878 finished externally with red enamel paint. Capacity 22.5 kg.
26
-
-
... More
Loop Card for FACP Adressable
2
-
-
... More
Shut off Nozzle
8
-
-
... More
Providing, laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS:1239 and IS:3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground, including excavation & providing cement concrete thrust blocks as supports, inclyding anticorrosive treatment with coaltar/asphalt tape as per IS:10221 , refilling the trench etc. of following sizes complete as required. 80 mm dia
24
-
-
... More
Providing, laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS:1239 and IS:3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground, including excavation & providing cement concrete thrust blocks as supports, inclyding anticorrosive treatment with coaltar/asphalt tape as per IS:10221 , refilling the trench etc. of following sizes complete as required. 150 mm dia
30
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 6mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes complete. Pipes upto 50mm dia threaded joints with holdite, 65mm and above should be welded joint.200 mm dia
280
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 6mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes complete. Pipes upto 50mm dia threaded joints with holdite, 65mm and above should be welded joint.40 mm dia
12
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 6mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes complete. Pipes upto 50mm dia threaded joints with holdite, 65mm and above should be welded joint.32 mm dia
40
-
-
... More
Providing, fixing and jointing including testing heavy quality Mild Steel pipes conforming to IS:1239 or IS:3589 - 6mm thick including cutting, threaded or welded (all type) joints as per detialed specifications.and providing suitable flanges wherever required,complete with necessary fittings viz bends, tees, reducers etc.required including fixing the pipes on wall/ceilling/ beam/floor with suitable hangers, clamps and painting the pipe of following sizes complete. Pipes upto 50mm dia threaded joints with holdite, 65mm and above should be welded joint.25 mm dia
330
-
-
... More
Suppy, installation, testing & commissitioning and putting into operation and final testing of MACHINE ROOM LESS TYPE automatic lift complete with ARD and all standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) 1981and fulfilling following requirments on turn key basis. A. Type - Passenger lift B. Load - 13 passenger/ 884 Kg C. Speed - 1.5 metre per second D. Contol - AC2 E. Operation -Microprosser based simplex collective selective with/without lift attendent F. Total rise - About 9 mtrs G. Landings - 4 All on same side H. Floors served - G,1,2,3 I. Signals -Digital car position indicator, car travel direction indicator in car & at all landings J. Lift shaft size - About 2500 mm width X 1900 mm depth, finished with plaster K. Lift car size - About 2000 mm width X 1100 mm depth L. Car entrance - Minimum Clear opening 900 mm wide X 2000 mm high protected with car door M. Landing entrance- Clear opening 900 mm wide X 2000 mm high protected with landing door N. Car door -Stainless steel two pannel centre opening flush type O. Landing door - Mild steel two pannel centre opening flush type P. Door operation-Automatic electric power operated door with infra red protection Q. Car interior - Stainless steel pannel with hair line/ moon rock finish on all sides R. Car floor - Hard wood covered with PVC/ marblex tiles S. Car ceiling & lighting - Fluorscent lighting concealed by suspended false ceiling with plain acrylic diffuser. The frame of suspended false ceiling shall be of powder coated aluminium T. Car ventilation- Pressure fan with anodised aluminium grill U. Emergency lighting in car- Battery operated Emergency lighting in the lift car V. Intercom system -Battery operated Intercom system in lift car, machine room and control room W. Emergency alarm - Battery operated alarm bell system in lift car & contol room X. Position of machine room-Directly above the lift shaft Y. Electric power supply - AC 415 Volts 3 phase 50 Hz terminated in machine room Z. Fire man switch -Fire man switch at main landing termanal
5
-
-
... More
Add or deduct for providing all additional parts/ equipments or for enhancing the capacity of parts/ equipments in MACHINE ROOM LESS TYPE automatic lift for 13 persons, speed 1.5 m/sec for every additional floor beyond initial G+3 floors.
15
-
-
Evaluation Notes How It Works ?