Water Resources Department Tender
View complete overview of Chandigarh WRD Tender
Water Resources Department - WRD Tender
Eprocure
Opening Date18 Oct 2018
Closing Date31 Oct 2018
Tender Amount₹ 16,50,000
Costs
EMD
₹ 33,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_WR_21704_1Tender No
05/22ATender Authority
Water Resources Department ViewPurchaser Address
-Website
http://eproc.punjab.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Compaction, Watering and rolling of Earth work in ordinary soil, (exclusive of compensation of earth) for laying earth/fly ash as per specifications for compaction in 20 cm layers and dressing and rolling to specifications.
1
-
-
... More
Dressing of earth work ( New work)
1
-
-
... More
Laser levelling of land up to 300 mm with tractor & Laser Levelling Machine complete in all respect.
1
-
-
... More
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation
1
-
-
... More
Cement Concrete 1:4:8 with stone ballast of
size 40mm + 20mm guage
1
-
-
... More
First class burnt brick work laid in cement sand
mortar 1:4 in foundation and plinth.
1
-
-
... More
Providing and laying 60 mm thick factory
made cement concrete interlocking paver block of M-35 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Light Traffic Areas such as Pedestrian plazas, shopping complexes, ramps, car parks, office driveways, housing colonies, office complexes, rural roads with low volume traffic, farm houses, beach sites, tourist resorts, local authority footways, residential roads, etc.
1
-
-
... More
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade made by block making machine with strong vibratory compaction
and of approved size and design / shape laid in Dark fast Colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Light Traffic Areas such as Pedestrian plazas, shopping complexes, ramps, car parks, office
driveways, housing colonies, office complexes, rural roads with low volume traffic, farm houses, beach sites, tourist
resorts, local authority footways, residential roads, etc.
1
-
-
... More
Scraping Cement Plaster on Walls.
1
-
-
... More
Plastering on walls 10 mm thick cement plaster 1:4
1
-
-
... More
White washing (two coat)
1
-
-
... More
Providing, Stringing out U.P.V.C. Pipes casting as
per IS:15328-2003 class-SN-8 along the trenches
and laying the same in Trenches to correct alignment
and gradients, cutting and jointing including cost of
specials complete as per specifications. 200mm o/d pi
1
-
-
... More
Constructing brick masonry manhole in cement
mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top
slab with 1:2:4 mix (1 cement: 2 coarse sand : 4
graded stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement: 4 coarse
sand : 8 graded stone aggregate 40mm nominal size)
inside plastering 12mm thick with cement mortar 1:3
(1 cement: 3 coarse sand) finished with floating coat
of neat cement and making benching in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20mm nominal size) finished with a
floating coat of neat cement, Orange coloured PVC
steps including FRCC cover with frame (light duty)
455x610 mm internal dimensions.complete as per
standard design. Inside size 75x120 cm and 120 cm deep.
1
-
-
... More
R.C.C. Manhole cover 560mm i/d Medium duty (on existing manholes at site)
1
-
-
... More
Turfing of lawns with fine grass including
ploughing dressing including/breaking of
clods, removal of rubbish, dressing and
Supplying of doob grass roots at 10 cm. apart
includng Supplying & spreading of manure @
0.60 cum per 100 sqm.
1
-
-
... More
"Brick edging of footpaths with Ist class bricks
including excavation, refilling, consolidating
with hand packing and spreading neatly
surplus earth within a lead of 50 m
1
-
-
... More
Providing Of MS Park Bench duly Green Coloured seating capacity 3 persons per bench. Including provn of foundation 1:2:4 cement concrete in legs by grouting bolts of suitable size in foundation
1
-
-
... More
Grass/Weed Cutting machine with suitable size of cable operating on 230 Volts
1
-
-
... More
Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required no. of bus-bar strips of suitable length and crosssectional area. Copper strips of suitable length and crosssectional area should be tinned and mounted on DMC/ SMC moulds at sufficient distance enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site. Sheet metal bus bar chamber suitable for 100amp. 415
volts capacity with 4 tinned copper strip bus bars each of length 270mm and cross sectional area (25mm x 3.3mm) enclosure having over all dimensions (350mm x 450mm x 150mm) nominal
1
-
-
... More
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) and relevant PWD general specifications 2010 complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of
Thimbles etc. MCCB (Fixed Type Thermal and Magnetic Protection Make: L&T (DU/DH), ABB (T-MAX), Schneider (CVS), Seimens(3VT1/3VL)): 100amp. 415 volts breaking capacity 25kA four pole fixed type thermal and magnetic setting MCCB unit. [CSR 33.23 A (ii)] (Premium 5%)
1
-
-
... More
S/E of Microprocessor Based St. Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, 3 nos. three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, 1 no. aux. contactor 6 amp.(2NO+2NC) with coil voltage 220V AC, 3 nos. MCB 2 pole 40amp. (Ccurve, 10kA)& power wiring with single core PVC insulated FRLS cable 10 sq. mm and control wiring with PVC insulated FRLS cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 2 nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mmx600mmx150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge. [CSR 33.26 B (i)] (Premium 5%)
1
-
-
... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 15mm) including erection of
the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).
1
-
-
... More
Supply & laying of alluminium conductor XLPE/ P.V.C. insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:- Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 25sq.mm (3 ½ Core)
1
-
-
... More
Supply & laying of alluminium conductor XLPE/ P.V.C. insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:- Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts
grade 10 sq.mm (4 Core)
1
-
-
... More
Supply and erection of G.I. pipe ‘A’ quality of suitable length and dia. conforming to I.S. 1239 part-I 1979, including fixing up to a given depth below G/L, the hole of excavation about 30 cm dia. and given depth to be filled in up to 15 cm below and above G/L with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thick ness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a MCB distribution board SPN 4way with hinged water tight cover with locking arrangement having one single pole MCB of required capacity of the same size the outer surface of the plinth to be finished with 1:2 cement plaster 6 mm thick M.S. fuse box shall have a water proof hinged cover with locking arrangement including painting of pole with two coats of approved aluminium paint as required:- 6.1 metre long having nominal bore dia. 80mm, planting depth 120cm with pit depth 135cm.
1
-
-
... More
Supply and erection of G.I. pipe 40mm dia. (A-class) single arm bracket atleast 1 metre long arm to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the top of the GI pipe pole having top outer dia. 80mm with GI reducer 80mm x 40mm with two
coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site.
1
-
-
... More
Supply and Fix LED type 25 Watt Street Light Fittings Make: Havell's/Philips/Wipro
1
-
-
... More
Any Other Item
1
-
-
Evaluation Notes How It Works ?