Punjab Engineering College Tender
View complete overview of Chandigarh PEC Tender
Punjab Engineering College - PEC Tender
Civil And Construction
Electrical and Electronics
Consultancy Services
Civil And Architectural Services
Electrical Works
Eprocure
Opening Date13 Nov 2024
Closing Date20 Nov 2024
Tender Amount₹ 15,53,061
Costs
EMD
₹ 31,061Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PEC_83342_1Tender No
PEC/EO/03Tender Authority
Punjab Engineering College ViewPurchaser Address
-Website
http://https://www.pec.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
-
-
-
Glazed vitrified floor tiles polished finish of size
-
-
-
Size of Tile 600 x 1200 mm
175
1612
282231.25
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
-
-
-
Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
27
3908
105537.6
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
-
-
-
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
55
1145
63027.25
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
315
214
67504.5
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
300
123
37155
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
-
-
-
Two coats
300
119
35760
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.
-
-
-
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
300
62
18735
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
260
20
5421
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
-
-
-
One or more coats on old work
141
86
12203.55
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
176
2
501.6
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter- locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross- T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
-
-
-
With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
160
2055
328904
providing and fixing of zebra blinds
40
3200
128000
Opening and refixing of benches
24
500
12000
Electrical Work
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
26
1467
38142
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
-
-
-
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
-
-
-
Group C
2
894
1788
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
14
858
12012
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
3 x 1.5 sq. mm
120
95
11400
3 x 2.5 sq. mm
250
137
34250
3 x 4 sq. mm
20
206
4120
3 x 6 sq. mm
20
304
6080
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
40
128
5120
25 mm
130
145
18850
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 A switch
2
103
206
15/16 A switch
2
156
312
3 pin 5/6 A socket outlet
2
122
244
6 pin 15/16 A socket outlet
8
197
1576
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
12
369
4428
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
6
40
240
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
1 or 2 Module (75mmX75mm)
8
298
2384
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
2
477
954
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
4
586
2344
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
-
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
-
-
-
100/63 A,30KA,FPMCCB
2
7723
15446
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
8 way , Double door
1
2573
2573
12 way , Double door
1
2315
2315
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
4 way (4 + 12), Double door
-
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
64
256
16384
Single pole and neutral
1
599
599
Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.
6
13
78
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
-
-
-
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
-
-
-
For 4 way, Double door TPN MCBDB
-
-
-
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
2
1170
2340
Supply,erection,testing and commissioning of ceiling fans 1400mm sweep One star rating white color with copper winding but without regulator complete with aluminium blades, plastic canoples 2 nos, double ball bearing, MS hanging rods, etc. complete in all respect. The job includes Installation, testing and commissioning of ceiling fan, including wiring with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required upto adjacent light point complete in all resepect.
Makes Havells-Velocity ES/Orient- Summer-Breeze Pro /Crompton-High Speed/Bajaj- SABSE TEZZ-EE only
12
3969
47628
Supply ,installation, testing and commissioning of recessed type LED panel 2'x 2',having CRCA housing duly painted with diffuser, minimum 4200 lumens (120 lumens/watt),5700K/6500K and 50000 burning hours of make Philips RC 380-B LED 42S-6500-G6/ Wipro CRCO10R036HE57G3 / Havells PLANO 2X2 PLR 36W LED865TAPS/Bajaj-BZRSQL43L-LEDGXPROWH.The job inculdes the cost of testing, commisisoning and making connection with 3*1.5 sq mm copper wire upto 1.5mt from adjacent light point, other petty material and labour etc as required to complete the same to the entire satisfaction of Engineer in Charge.
28
3164
88592
Supply ,installation, testing and commissioning of Surface type LED panel 2'x 2',having CRCA housing duly painted with diffuser, minimum 4200 lumens and 50000 burning hours of make Philips - SM365C LED 32-6500 PSUODWH/WIPRO-CRC 010SO0-38HP57GL1/ Havells-Piano suface 36W.The job inculdes the cost of testing, commisisoning and making connection with 3x1.5 sq mm copper wire from adjacent light point, other petty material and labour etc as required to complete the same to the entire satisfaction of Engineer in Charge.
-
-
-
Supply and errection of 1x20 watt 4' long LED box type fittings with decortative end caps of make Crompton CAT no. DMLNILT8-16+LT8-20-865-2 or equivalent models of make Philips/Surya make only .The LED tube rod 20 watt polycarbonate with inbuilt driver, extruded aluminium heat sink, 30000 burning hours at 70% lumens maintenance of makes Philips/Havells/Wipro/Crompton/Bajaj. The job includes carriage, erection, making connections with 3x1.5 sq.mm copper wire from adjacent light point, testing and commissioning of the fittings etc. as requried to complete the same to the entire satisfaction of engineer in charge.
-
-
-
Supply and erection of fan rod made of seemless MS pipe dia duly powder coated complete in all respect. Make National
-
-
-
30" length
12
190
2280
Supply and erection of Modular type DP switch 32 Amp 250 Volt along with modular box, modular base and cover plat 2 module complete in all respect.Make Legrand (Lyncus)/ABB (Tvisha/ Gold Medal(GIFA) Crabtree (Athena)
8
655
5240
Supply and fixing of 63 amp rating, TPN MCB 415V, 10KA"C" curve miniature circuit breaker suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning as required.Makes Havels/ABB/L&T/Schnieder
-
-
-
Supply and fixing of TPMCB 63 amp rating, 415V, 10KA"C" curve miniature circuit breaker suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning as required.Makes Havels/ABB/L&T/Schnieder
-
-
-
Providing and fixing of MS 10mm dia U type fan hook which includes fixing in the steel bar of RCC slab and repairing the same in good condition.
12
175
2100
Providing and Fixing of PVC Rigid drain Pipe surface/recess with necessary repair to the original condition, complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾” including specials- Make- Diplast or Equalivent.
90
110
9900
Supplying and fixing of Surface/recess mounting 8 way TP &N vertical load line distribution board double door steel, dust protected, duly powder coating inclusive of tinned copper bus bars,160Amp (W/o MCCB) and outgoing MCB's (Without MCB's) complete in with all petty material and labour required.
Makes Havels/ABB/Schnieder
2
13971
27942
Supply and fixing of 40 amp rating, 415V, 10KA"C" curve Single pole & Neutral miniature circuit breaker suitable for inductive load in the existing DB complete with connections, testing and commissioning as required.Makes Havels/ABB/Schnieder
1
1181
1181
Supply,erection testing and commissioning of UTP cat 6 information oulest (Red for data user end) complete in all respect upto the entire satisfaction of engineer in charge of the work make Molex/R&M/Semon/D-Link
2
310
620
Supply,erection testing and commissioning of UTP cat face plate (singal/dual) along with modular box 75mmx75mm complete in all respect upto the entire satisfaction of engineer in charge of the work make Molex/R&M/Semon/D-Link
2
250
500
Dismantling of existing LAN cable and relaying in existing PVC conduit pipe complete in all respect.
40
20
800
Supplying and fixing of suitable size GI box with modular plate and cover 12 modules in front on surface or in recess, including providing and fixing 4 nos 5/6 A modular switch, 3 nos 5/6 A modular socket outlet and one 10 AMP international socket, with necessary connections etc. as required. (for computer plugs to be used in non residential buildings.)
2
1544
3088
Disconnection of existing single/ three phase, cable connections/ circuits of existing distribution boards & irrespective of number of circuits and reconnections in new distribution boards complete in all respect to make the supply functional
-
-
-
Single phase upto 12 way
2
1000
2000
Three phase upto 6 way
2
2000
4000