Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PGIME_823885_1Bid Award Id
ViewTender No
PGI/Engg./Elect./2024-25/34Tender Authority
Postgraduate Institute Of Medical And Education And Research ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
SITC of 2 No. ACB, 630 Amps, 50 kA, 4 Pole with both side adopter link Microprocessor Based (EDO) Inbuilt variable O/L (Phase & Neutral), S/C with time delay & Inst S/C , E/F protections , Under & Over Voltage protection, with 2 nos NO & NC auxiliary contacts (Ics=Icu=Icw=50 KA for 1 sec) Shunt Trip release & Under Voltage release.
-
-
-
Incomer for DG 500 KVA
-
-
-
SITC of 1 No. ACB, 800 Amps, 50 kA, 4 Pole with both side adopter link Microprocessor Based (Four Pole) (EDO) Inbuilt variable O/L (Phase & Neutral), S/C with time delay & Inst S/C , E/F protections , Under & Over Voltage protection, with 2 nos NO & NC auxiliary contacts (Ics=Icu=Icw=50 KA for 1 sec) Shunt Trip release & Under Voltage release.
-
-
-
BUS COUPLER I & II
-
-
-
Supply, Installation, Testing and commissioning of 2 No. ACB, 1250 Amps, 50 kA, 4 Pole with both side adopter link Microprocessor Based (Four Pole) (EDO) Inbuilt variable O/L (Phase & Neutral), S/C with time delay & Inst S/C , E/F protections , Under & Over Voltage protection, with 2 nos NO & NC auxiliary contacts (Ics=Icu=Icw=50 KA for 1 sec) Shunt Trip release & Under Voltage release.
-
-
-
BUS BARS
-
-
-
TPN Bus bars, 1600 Amps, with 100% neutral of Aluminum conductor with heat sinkable sleeves.
-
-
-
OUTGOING
-
-
-
Supply, Installation, Testing and commissioning of 2 No. ACB, 1250 Amps, 50 kA, 4 Pole with both side adopter link Microprocessor Based (Four Pole) (EDO) Inbuilt variable O/L (Phase & Neutral), S/C with time delay & Inst S/C , E/F protections , Under & Over Voltage protection, with 2 nos NO & NC auxiliary contacts (Ics=Icu=Icw=50 KA for 1 sec) Shunt Trip release & Under Voltage release.
-
-
-
Auto Synchronization System with Load Management :
-
-
-
SYN. Relay having Protection, Auto Synchronization, Auto Load Management, Auto Load Sharing and Auto Changeover Feature. - 03 Nos.
-
-
-
Detailed Inbuilt Feature in Syn Relay :
-
-
-
Short-circuit, Over-current
-
-
-
Voltage-dependent over-current, Overvoltage, under voltage
-
-
-
Over frequency, under frequency, Unbalanced voltage
-
-
-
Unbalanced current, Under excitation or Var import
-
-
-
Over excitation or Var import, Overload, Busbar/Mains O/V
-
-
-
Busbar/Mains Under voltage, Busbar/Mains Over frequency
-
-
-
Busbar/Mains Under frequency
-
-
-
Busbar/Mains Unbalanced Voltage, Emergency Stop
-
-
-
Over-speed, Low-High Battery Voltage
-
-
-
Generator Breaker(GB) External Trip, Mains Breaker (MB) External Trip
-
-
-
GB Synchronization Failure, GB Open Failure
-
-
-
MB Synchronization Failure, MB Open-Close Failure
-
-
-
Phase Sequence Error, Hz/V Failure, Fuel fill check error
-
-
-
EIC warning via J1939/comm. Link
-
-
-
EIC Coolant temperature via J1939/comm. link
-
-
-
EIC oil pressure via J1939/comm. link
-
-
-
Instrument and Component Section : For Auto Synchronization System + Load management
-
-
-
6A DP 10kA Control MCB - 06 Nos.
-
-
-
16A DP 10kA Control MCB - 06 Nos.
-
-
-
Auxiliary Contactor - 2NO+2NC - 10 Nos.
-
-
-
Emergency Stop Push Buttons 220V AC - 03 Nos.
-
-
-
Battery Charger INPUT 220V/24V 20A - 03 Nos.
-
-
-
D.G Selection switch 3Way 3P with off - 03 Nos.
-
-
-
Mode Selection switch 3Way 2P with off - 03 Nos.
-
-
-
Terminal Block 2.5mm2 (Lot) - 03 Nos.
-
-
-
Aux. Relay 24V DC - 36 Nos or as required.
-
-
-
Hooter for Alarm - 24V DC - 03 Nos.
-
-
-
Programming, Erection, Commissioning and Testing of SYN. Relay
-
-
-
Current Transducer - 85...253VAC/90...320VDC or 20...40VAC/20....60VDC - 03 Nos.
-
-
-
Each incomers and outgoings (3 nos. DG set & 02 nos. Outgoing) should have provision of termination of sandwich type bus trunking
-
-
-
Electrical/ mechanical interlocking among the Incomers, Bus couplers as per site requirement must be provided upto the satisfaction of Engineer Incharge with proper control wiring for operation of systems.
-
-
-
Each ACB shall have one set of the following items:
-
-
-
Intelligent multi function digital meter Datalog (8 MB),Analog I/O, digital I/O variants available, Meter with Ethernet port available Parameters: V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interupts, Phase angle, THD, Neutral current, Max Demand (with RTC), Events (high-low) with time stamp, Individual Harmonics upto 31st.
-
-
-
All ACBs shall have Ics=Icw for 1.0 secs for all ACBs
-
-
-
1 Set Indication Lamps, LED type, for RYB with2 Amp control MCB.& breaker 'ON', 'OFF', 'TRIP' & spring charged lamps with 2 Amp MCB for controlling alonwith SITC of TNC switch.
-
-
-
As above
1
2171635
2171635
Supply of 3.5 core aluminium conductor, XLPE insulated PVC sheathed armoured cable confirming to IS : 7098 (part – I), 1100 v Grade of the following sizes.
-
-
-
240 mm2
100
148900
1489
400 sq. mm
395
976835
2473
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
-
-
-
160 mm dia (OD-160 mm & ID-135 mm nominal)
230
110630
481
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 kv grade as reqd.
-
-
-
3½ X 400 sq. mm (82mm)
2
3112
1556
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
-
-
-
Above 185 sq. mm and upto 400 sq. mm
360
40320
112
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
40
9040
226
Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 1.1 kv grade of following size on cable tray as reqd.
-
-
-
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
100
18500
185
Shifting of old 160 KVA DG Set alongwith panel, exhaust structure from Guest House to ESS2 at site as desired by engineer in charge. job includes installation and fixing of DG Set, connection of fuel pipe using welding/threading to Diesel Tank from engine, Exhaust pipe on foundation/ support structure by use of welding at Site.
1
26232
26232
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
55352
13838
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection /terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
50
42650
853
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
2
15567
7783.65
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
1
6050
6050.65
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
3.5
1077
307.95
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
-
-
-
Cement mortar 1:6 (1 cement : 6 coarse sand)
1
6658
6658.25
12 mm cement plaster of mix :
-
-
-
1:6 (1 cement: 6 coarse sand)
3.5
987
282
Add difference of enhanced GST@18% (MF=0.0633)
3633547.03
230003
0.06