Postgraduate Institute Of Medical Education And Research Tender
View complete overview of Chandigarh PGIMER Tender
Postgraduate Institute Of Medical Education And Research - PGIMER Tender
Laboratory Equipment and Services
GEM
Opening Date10 Oct 2024
Closing Date31 Oct 2024
Tender Amount₹ 30,00,000
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2024/B/5491899Tender No
GEM/2024/B/5491899Tender Authority
Postgraduate Institute Of Medical Education And Research ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
pul_dlc_2024-10-10-12-04-36_bf1cc30b0bbf5762b87813a398084879.pdf
dlco_with_mbw_2024-10-10-12-04-36_f694de2cbfcc9b72f0ebe79f1a0b82de.csv
BOQ Items
Ability to complete spirometry test including standard parameters i.e. FVC, SVC and MVV. , As per specifications
1
-
-
Should have bronchial challenge test , As per specifications
1
-
-
Should have Z Score LLN and percent predicted for fast interpretation of results , As per specifications
1
-
-
Display lung age and BMI value in the reports , As per specifications
1
-
-
Facility to incorporate FeNo measurement MIP MEP ABG and Spo2 , As per specifications
1
-
-
Should have spirometry tests all main important parameters , As per specifications
1
-
-
DLCO test parameters BHT COHb Dladj Dladj per VA DLCO DLCO per VA KCO FA CO FA HE FE CO FEV1per FVC FI CO FI HE FRC sb FRC Cor Kroghs K RV sb RV Cor Rv per TLC RV per TLC Cor TLC sb , As per specifications
1
-
-
MBW test parameters Cumulative expired volume CEV CEV5 ERV FRC base FRC extrapol , As per specifications
1
-
-
Free from Calibration test volume gas calibration not required , As per specifications
1
-
-
At least 12 inches color touch screen system , As per specifications
1
-
-
Compatible Computer all-in one with Intel i7 Processor atleast 12 generation or better 1TB SSD and 32 GB RAM Windows 11 and MS Office 2021 atleast 23 inches LED Monitor and laser jet printer , As per specifications
1
-
-
Ability to Indian predicted range , As per specifications
1
-
-
Print the ATS ERS-2019 inter prints algorithm , As per specifications
1
-
-
Facility of export data HL7 XML GDT via USB LAN Network , As per specifications
1
-
-
BIS ISO CE US FDA approved , As per specifications
1
-
-
Power 220 240 VAC 50 60 Hz , As per specifications
1
-
-
Flow Volume Sensor method with the following specifications , As per specifications
1
-
-
Type Ultrasonic transits time , As per specifications
1
-
-
Range flow 16 L per Sec , As per specifications
1
-
-
Flow Resolution 4 ml per second , As per specifications
1
-
-
Flow Accuracy except PEF 2percent or zero point two l per s , As per specifications
1
-
-
Resistance equal zero point three cm H2Oper l per s at 16 l per s , As per specifications
1
-
-
Sample Rate 400 Hz , As per specifications
1
-
-
CO gas sensor with the following specifications , As per specifications
1
-
-
Type Non dispersive infrared , As per specifications
1
-
-
Range 0 to zero point 35 percent , As per specifications
1
-
-
Resolution 0 point 0001 percent , As per specifications
1
-
-
Accuracy plus minus 0 point 001 percent , As per specifications
1
-
-
Helium tracer gas sensor with the following specifications , As per specifications
1
-
-
Type Ultrasonic transit time , As per specifications
1
-
-
Range 0 to 50 percent , As per specifications
1
-
-
Resolution 0 to 02 percent , As per specifications
1
-
-
Accuracy 0 point 05 percent , As per specifications
1
-
-
Should have Standard supplies includes , As per specifications
1
-
-
Trolley original manufacturer OEM integrated with all system , As per specifications
1
-
-
DLCO gas cylinder with regulator and key opner 02 Nos , As per specifications
2
-
-
PFT Filter , As per specifications
400
-
-
Ultrasonic flow sensor , As per specifications
400
-
-
Mouth Pieces , As per specifications
1000
-
-
Nose clips 100 Nos , As per specifications
100
-
-
Printing paper for print report 24 Rim , As per specifications
24
-
-
Two computer chair with arm for operator , As per specifications
2
-
-
Five years warranty and Five CMC after expiry of warranty period All sensors should be cover under warranty and CMC period , As per specifications
1
-
-
Physical demonstration if required at PGIMER Chandigarh , As per specifications
1
-
-
Price of following consumable should be frozen for ten years , As per specifications
1
-
-
DLCO gas cylinder , As per specifications
1
-
-
PFT Filter , As per specifications
1
-
-
Ultrasonic flow sensor , As per specifications
1
-
-
Mouth Pieces , As per specifications
1
-
-
Evaluation Notes How It Works ?