Postgraduate Institute Of Medical And Education And Research Tender
View complete overview of Chandigarh PGIMER Tender
Postgraduate Institute Of Medical And Education And Research - PGIMER Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 50,70,142
Costs
EMD
₹ 1,01,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PGIME_841844_1Tender No
PGI/Engg./Elect./2024-25/51Tender Authority
Postgraduate Institute Of Medical And Education And Research ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
All incomers and buscouplers feeders shall have Intelligent multi function digital meter Datalog (8 MB), I/O Ethernet port available Parameters: V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interupts,Phase angle, THD, Neutral current, Max Demand (with RTC), Events (high-low) with time stamp, Individual Harmonics upto 31st.
-
-
-
... More
All MCCBs to have 1 Set Indication Lamps, LED type, for RYB with 2 Amp control MCB.& breaker 'ON', 'OFF', 'TRIP' with 2 Amp MCB for controlling.
-
-
-
... More
All MCCBs to have Ics = Icu =100% Icw, alongwith accessories like panel mounted rotary extanded handle mechnism ,spreader links Phase barriers, etc.
-
-
-
... More
Incomers
-
-
-
... More
02 nos. 600/630 A 50 KA FP MCCB,415Volts, 3 phase, 50 Hz AC with microprocessor based protection release & required Breaking capacity with adjustable protection for over load, short circuit and Instantaneous protection conforming to IEC 60947/IS 13947/Part.II/1993 (Latest version). All microprocessor MCCBs shall have in-built display to view the breaker last trip data for faster fault diagnosis. MCCBs should have switchable thermal memory and inbuilt communication port for periodic health checkup diagnosis through software with software subscription should be free of cost. Breaker shall be equipped with pre-overload & overtemperature alarm indication.
-
-
-
... More
Buscoupler 1
-
-
-
... More
01 nos. 600/630 A 50 KA FP MCCB, 415Volts, 3 phase, 50 Hz AC with microprocessor based protection release & required Breaking capacity with adjustable protection for over load, short circuit and Instantaneous protection conforming to IEC 60947/IS 13947/Part.II/1993 (Latest version). . All microprocessor MCCBs shall have in-built display to view the breaker last trip data for faster fault diagnosis. MCCBs should have switchable thermal memory and inbuilt communication port for periodic health checkup diagnosis through software with software subscription should be free of cost. Breaker shall be equipped with pre-overload & overtemperature alarm indication.
-
-
-
... More
Buscoupler 2
-
-
-
... More
01 nos. 250 A 36 KA FP MCCB,415Volts, 3 phase, 50 Hz AC with microprocessor based protection release & required Breaking capacity with adjustable protection for over load, short circuit and Instantaneous protection conforming to IEC 60947/IS 13947/Part.II/1993 (Latest version). All microprocessor MCCBs shall have in-built display to view the breaker last trip data for faster fault diagnosis. MCCBs should have switchable thermal memory and inbuilt communication port for periodic health checkup diagnosis through software with software subscription should be free of cost. Breaker shall be equipped with pre-overload & overtemperature alarm indication.
-
-
-
... More
Incomer UPS
-
-
-
... More
one no. 250 Amps FP Auto Transfer switch and it's microprocessor digital programmable controller suitable for various event selection having digital display of voltage, current, Frequency with mimic.
-
-
-
... More
Accessories for Interlocking
-
-
-
... More
Mechnical interlocking among the Incomers, Buscouplers and Tie interconnections as per site requirement must be provided upto the satisfaction of Engineer incharge .
-
-
-
... More
Bus Bar
-
-
-
... More
TPN with 100 % neutral aluminium bus-bars of minimum of 1000 amps capacity for bus 1 & 2 and 500 amps capacity for bus 3 with heat shrinkable coloured sleeves and i/c SMC bus-bars supports at required intervals complete for cross section, size supports & their spacing etc .
-
-
-
... More
Outgoing
-
-
-
... More
(i) 11 nos. 100 Amp and 01 no. 250 Amp TP MCCB 36KA TM release for bus 1.
(ii) 11 nos. 100 Amp and 01 no. 250 Amp TP MCCB 36KA TM release for bus 2. (iii) 6 no. 100 Amp TP MCCB 36KA TM release for bus 3
-
-
-
... More
Panel as above
2
1695392
3390784
... More
Supply of 3.5 core aluminium conductor, XLPE insulated PVC sheathed armoured cable confirming to IS : 7098 (part – I), 1100 v Grade of the following sizes.
-
-
-
... More
300 sq. mm
300
2107
632100
... More
Supply of 4 core copper conductor, XLPE insulated PVC sheathed armoured cable confirming to IS : 7098 (part – I), 1100 v Grade of the following sizes.
-
-
-
... More
10 mm2
300
876
262800
... More
16 mm2
230
1351
310730
... More
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 kv grade as reqd.
-
-
-
... More
3½ X 300 sq. mm (70mm)
20
1195
23900
... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
-
-
-
... More
4 X 10 sq. mm
20
510
10200
... More
4 X 16 sq. mm
40
545
21800
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
-
-
-
... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
300
185
55500
... More
Upto 35 sq. mm (clamped with 25x3mm MS flat clamp)
1010
45
45450
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
-
-
-
... More
150 mm width X 50 mm depth X 1.6 mm thickness
125
716
89500
... More
Dismentling of old cable
480
30
14400
... More
Dismentling of old Panels
12
2000
24000
... More
Add difference of GST @ 6% (MF=6.33%)
4881164
-
308978
... More
Rebate on existing old panel etc… from site, including transportation to Outside PGI. Old cables will be taken by department.
-
-
-
... More
Rebate on SFU Panel
12
10000
-120000