Panjab University Tender

View complete overview of Chandigarh PU Tender

Panjab University - PU Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date6 Sep 2024
Closing DateCancelled
Tender Amount₹ 22,26,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
chippings complete as per design of existing precast panels fixed on walls. (The reinforment to be provided in precast panels will be paid separately) (N.S)

1.5

8593

5729

... More
Refixing of already removed servicable panels after cleaning of residual materials/mortar , backing filled ith a grout of average 30mm thick cment mortar1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with admixture to match the colour/shade of exiting pointing (precast panel to be secured to backing and sides by means of crampus and pins which shall be paid searately. (N.S)

2

9144

4572

... More
Fixing in place of loose precast panels ( less than ¾" out of its plane) into its original position after removing the loose mortar from joints on sides and back where possible and filling joints with mortar 1:3 ( 1 cement: 3 coarse sand). Paning/ anchoring with anchoring system may be done as additional measure it required in a particular case. ( The payment for anchoring system shall be made separately.) (N.S)

34

163676

4814

... More
Providing and fixing stainless steel cramps of required size and shape for anchoring precast R.C.C. panels to the backing wall in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.(DSR ref no. 8.15)

275

198000

720

... More
Steel reinforcement for precast R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.(DSR ref no. 5.22)

-

-

-

... More
Mild steel and Medium Tensile steel bars (DSR ref no.5.22.1)

544

57120

105

... More
Patch repair of top layer of 10mm thick of already fixed precast R.C.C. panels after cutting the pactch in proper shape, preparing the surface, applying cement slurry and providing top layer of cment plaster with mixture of 1 white cement: ½ marble powder : 2 marble chippings 10mm nominal size) including scrubbing and washing the top layer with brushes and water to expose the stone chippings complete.(N.S)

66

62040

940

... More
Cracks treatment: Small fractures should be cut along the line of fractures and clean with water jet and plugged with Cement mortar with Crack -X powder or Paste placed by hand. When the mortar has cued the fracture should be grouted with liquid mortar { The quantity of water should be enough to create a very mobile grout with 10% Dr fix Pagel ZS 10 with 1:1 cement mortar ( 1 Cement : 1 fine sand)} (N.S)

100

106500

1065

... More
Treatment of Exposed rebar (25 %) with corrosion only till the surface

-

-

-

... More
Providing corrosion inhibitor or primer after scraping the reinforcement for any damage to its outer layer with sandpaper and rust remover and installing a new patch over it to match the existing panel as specified in 6mm dia rod as required (N.S)

4

3040

760

... More
Treatment Exposed rebar - Corroded and unwinded (N.S)

-

-

-

... More
Replacement of the corroded portion of the reinforcement, by welding with a new reinforcement of the same diameter and strength and coating with corrosion inhibitor and finishing by providing a patch to match the existing panel as specified in as specified in 6mm dia rod as required

5

78370

15674

... More
Repointing for Open joints (N.S)

-

-

-

... More
Providing recessed pointing around the panels to finally secure them in place. Pointing of cement sand mortar 1:2: (1 cement : 2 clean washed coarse river sand) with admixture of marble dust matching the panel shade.

-

-

-

... More
Flush pointing around panels with cement and coarse sand in the ratio 1:3 (1 cement : 3 washed clean river coarse sand).

1500

819000

546

... More
Vegetation Removal (N.S)

-

-

-

... More
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.

214

8346

39

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-incharge. (DSR ref no. 24.2)

-

-

-

... More
Note:- (1) The elevational area of the scaffolding shall be measured (7' less height) for payment purpose. (2) The payment will be made once only for execution of all items for such works

1150

294400

256

... More
Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. (DSR ref no. 7.32)

-

-

-

... More
White sand stone (DSR ref no. 7.32.2)

3

261282

87094

... More
Protection of the bottom edge profile

-

-

-

... More
Removal of previously applied cement at the bottom of the building profile (Where the panels end).(Ref:-N.S.)

-

-

-

... More
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).

-

-

-

... More
25 mm average thickness in 2 layers.(Ref:-N.S.)

50

25000

500

... More
Cleaning the surface of Building (Ref. N.S)

-

-

-

... More
Cleaning the stone surface and removing dirt, dust, bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agent as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building/ structure, all as per direction of Engineer-in-charge (The rate is inclusive of all materials & labours involved except scaffolding).

850

117300

138



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.