NHPC Limited Tender
View complete overview of Chandigarh NHPC Tender
NHPC Limited - NHPC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Dec 2024
Closing Date27 Dec 2024
Tender Amount₹ 35,43,522
Costs
EMD
₹ 71,000Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NHPC_837333_1Bid Award Id
ViewTender No
NH/ROCHD/PNC/CW12/2024/60Tender Authority
NHPC Limited ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, installation, testing and commissioning of following minimum capacity different flow VRV/VRF Cassette Type Indoor ceiling mounted unit. Detail of Specification as per Technical Specification Sheet attached. Cassette Unit - ≥ 1.30 TR, Min. CFM 600
1
-
-
... More
Supply, installation, testing and commissioning of following minimum capacity different flow VRV/VRF Cassette Type Indoor ceiling mounted unit. Detail of Specification as per Technical Specification Sheet attached. Cassette Unit - ≥ 1.65 TR, Min. CFM 812
2
-
-
... More
Supply, installation, testing and commissioning of following minimum capacity different flow VRV/VRF Cassette Type Indoor ceiling mounted unit. Detail of Specification as per Technical Specification Sheet attached. Cassette Unit - ≥ 2.00 TR, Min. CFM 830
1
-
-
... More
Supply, installation, testing and commissioning of following minimum capacity different flow VRV/VRF Cassette Type Indoor ceiling mounted unit. Detail of Specification as per Technical Specification Sheet attached. Cassette Unit - ≥ 2.50 TR, Min. CFM 860
2
-
-
... More
Supply, installation, testing and commissioning of following minimum capacity different flow VRV/VRF Hi-wall Type Indoor unit. Detail of Specification as per Technical Specification Sheet attached. Hi-Wall Unit - ≥ 1.00 TR, Min. CFM 388
5
-
-
... More
Supply, installation, testing and commissioning of following minimum capacity different flow VRV/VRF Hi-wall Type Indoor unit. Detail of Specification as per Technical Specification Sheet attached. Hi-Wall Unit - ≥ 1.50 TR, Min. CFM 530
4
-
-
... More
Supply, Installation, testing and commissioning of Ductable Type Indoor units high static equipped with, pre-filter, fan section with suitable static fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, drain pump, insulation, pipe connections, variable evaporative temperature control etc. of various capacities as per specifications and drawings. Ductable Unit- ≥ 8.00 TR, Min. CFM 2800
3
-
-
... More
Supply, Installation, testing and commissioning of Remote. Detail of Specification as per Technical Specification Sheet attached. Cordless Remote
16
-
-
... More
Supply, Installation, testing and commissioning of Remote. Detail of Specification as per Technical Specification Sheet attached. Corded Remote
3
-
-
... More
Supply and installation of Refrigerant Piping Y-Joints or Headers as required to connect the above outdoor units and indoor units. (liquid and gas line as one set)
16
-
-
... More
Supply, Installation, testing and commissioning of Centralized Controller for controlling the indoor units.
1
-
-
... More
SITC OF VRV/VRF (Heating & Cooling) AC System (GST @18%) (PART-A2)
-
-
-
... More
Supply, installation, testing and commissioning of following Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi including accessories, insulated with XPLE Class-O closed (6.4 mm dia (1/4) 19mm Thickness with insulation)
78
-
-
... More
Supply, installation, testing and commissioning of following Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi including accessories, insulated with XPLE Class-O closed (9.5 mm dia(3/8) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation)
79
-
-
... More
Supply, installation, testing and commissioning of following Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi including accessories, insulated with XPLE Class-O closed (12.7 mm dia (1/2)(OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation)
98
-
-
... More
Supply, installation, testing and commissioning of following Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi including accessories, insulated with XPLE Class-O closed (15.86 mm dia(5/8) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation)
60
-
-
... More
Supply, installation, testing and commissioning of following Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi including accessories, insulated with XPLE Class-O closed (19.1 mm dia(6/8) (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation )
43
-
-
... More
Supply, installation, testing and commissioning of following Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi including accessories, insulated with XPLE Class-O closed (22.2 mm dia (OD)(7/8) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation)
34
-
-
... More
Supply, installation, testing and commissioning of following Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi including accessories, insulated with XPLE Class-O closed (28.58 mm dia (11/8)(OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation)
40
-
-
... More
Supply, installation, testing and commissioning of following Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi including accessories, insulated with XPLE Class-O closed (34.9 mm dia(13/8) (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation)
16
-
-
... More
Supply, installation, testing and commissioning of following Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi including accessories, insulated with XPLE Class-O closed (41.3 mm dia(15/8) (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation)
20
-
-
... More
Refrigerant R-410A to top up the system.
35
-
-
... More
Providing and fixing (uPVC) pipes, having thermal stability for water supply, including all uPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (25 mm nominal outer dia Pipes.)
87
-
-
... More
Providing and fixing (uPVC) pipes, having thermal stability for water supply, including all uPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (32 mm nominal outer dia Pipes.)
57
-
-
... More
Supply, installation and commissioning of Site fabricated Galvanized rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (Thickness 0.63 mm ,24G & 22G)
35
-
-
... More
Supply, installation, testing and commissioning of Nitrile rubber class-O closed cell XPLE Fire retardant insulation of 9 mm thick pasted on the duct with suitable adhesive complete in all respects with Nitrile tapes
45
-
-
... More
Supply, installation, testing and commissioning of canvas for outlet connection of the equipment’s.
3
-
-
... More
Supplying, fixing testing commissioning of powder coated aluminum Fresh/Exhaust air louvers With/Without Damper and Bird screen.
5
-
-
... More
Supply of control cum transmission wiring of 2 core x0.75 sq mm copper wire in suitable PVC conduits between indoor & outdoor units.
515
-
-
... More
Comprehensive AMC Charges (PART-B)
-
-
-
... More
AMC Charges after 1st Year
1
-
-
... More
AMC Charges after 2nd Year
1
-
-
... More
AMC Charges after 3rd Year
1
-
-
... More
AMC Charges after 4th Year
1
-
-
... More
AMC Charges after 5th Year
1
-
-
... More
Buy Back Part (Part-C)
-
-
-
... More
BUYBACK OF EXISTING UNITS. (44TR) System including dismantling of exiting AC system
1
-
-
... More
Total value of bid : ('PART A (A1 &A2)' + 'PART B' - 'PART C')
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements