Municipal Corporation Tender
View complete overview of Chandigarh Municipal Corporation Tender
Municipal Corporation Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Oct 2024
Closing Date6 Nov 2024
Tender Amount₹ 14,99,505
Costs
EMD
₹ 29,990Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MCC_83054_1Bid Award Id
ViewTender No
85/E/MCC/2024Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://http://mcchandigarh.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
P/F of LED luminarie of size 2'x2' of 30-36 watt (595x595 mm) surface type including driver with system Lumens 3600-4000 Im having efficacy of minimum 100 lm/W. THD 10%, PF 0.95, Having coloured temperature 4000-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Havells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj alongwith connection, testing and commissioning erc. This job also includes all petty material required to be entire satisfaction of Engineer-in-charge. Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations.
14
5755
80570
... More
S/I/T/C OF 6-8 Watt Adjustable LED Downlighter, made of extruded aluminium housing and high power LED as alight source wih clear diffuser and including electronic driver with minimum 95 Lumens/watt, THD 10%, Pf 0.95, protection IP 20, and CCT 4000-5700K, Surge protection 4kV, Operating Voltage Range - 150V – 270Volts.MAKE- philips ,Wipro,Trilux,Osram,Havells, JAGUAR complete in all respect.Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. The work shall be executed to the entire satisfaction of Engineer-in-charge
95
1204
114380
... More
S/I/T/C OF 9-12 Watt LED Downlighter, made of extruded aluminium housing and high power LED as alight source wih clear diffuser and incluting electronic driver with minimum 100 Lumens/watt, THD 10%, Pf 0.95, protection IP 20, and CCT 4000-5700K, Surge protection 4kV, Operating Voltage Range - 150V – 270Volts.MAKE- philips ,Wipro,Trilux,Osram,Havells, JAGUAR complete in all respect.Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. The work shall be executed to the entire satisfaction of Engineer-in-charge
26
846
21996
... More
Supply and Erection of Exhaust fan (heavy duty motor with copper wound metallic body) following size complete with motor, mettalic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation,epoxy powder coating along with mettalic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. Size 12" Sweep 900 RPM with louver of Havells make Turbo Force SP/ Orient make Industrial heavy duty / Crompton make HDEF EXHD 300- 6-1 / Bajaj make Supreme DLX only. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
11
3141
34551
... More
Full stator copper rewiding of an ceiling fan (condensor type) of 1200/1400 mm sweep including (ball bearing if required) and cleaning and insulating the stator slots, sleeving, soldering, wrapping of cotton tape, re-assembling, varnishing and testing etc. complete in all respect. (in working condition). The work shall be executed to the entire satisfaction of Engineer-in-Charge.
25
511
12782
... More
Supply and installation of fan condenser of required microfarad. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
20
49
996.4
... More
P/F LED lamp 9 watt screw type lamp of make - Bajaj/Havells/ Wipro/ Philips. And work should be executed as per the entire satisfaction of Engineer in charge.
30
163
4916.1
... More
S/E of M.S. angle iron bracket of size40x40x6mm .The bracket should be painted with the coats of superior quality paint. The job includees all the material, labour including making holes in the bracket to fix the flood light fittings etc complete in all respect. The work shall be executed to the entire satisfaction of Engineer-in-charge.
7
721
5047.28
... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.. Make: ABB, Havells,Legrand, Northwest Wipro, Norysis, Captree (Murano), Schneider. 16 Module
6
327
1966.5
... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.. Make: ABB, Havells,Legrand, Northwest Wipro, Norysis, Captree (Murano), Schneider.
-
-
-
... More
2 Module DSR1.28.1
8
113
904
... More
4 Module DSR1.28.3
6
139
834
... More
6 Module DSR1.28.4
10
163
1630
... More
8 Module DSR1.28.5
6
193
1158
... More
12 Module DSR1.28.6
4
255
1020
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing
modular plate switch box including connections but excluding modular plate etc.
as required.Make: ABB, Havells,Legrand, Northwest Wipro, Norysis, Captree (Murano), Schneider. DSR 1.25
40
347
13880
... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group C DSR 1.15.3
32
733
23456
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connectioN.S (M.R) but excluding modular plate etc. as per existing installaed model as required. Make: Legrand, Northwest Wipro, Norysis, Captree (Murano), Schneider.
-
-
-
... More
3 pin 5/6 amp switch outlet DSR 1.24.1
45
87
3915
... More
15/16 amps switch outlet DSR1.24.3
35
140
4900
... More
3 pin 5/6 amp socket outlet DSR1.24.4
38
111
4218
... More
15/16 amps socket outlet DSR 1.24.5
35
181
6335
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make: Finolex/Polycab/Havells/KEI
-
-
-
... More
3x 1.5 sq. mm DSR 1.17.3
240
90
21600
... More
3x 2.5 sq. mm DSR 1.17.12
1850
132
244200
... More
3x 4 sq. mm DSR 1.17.21
2650
198
524700
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,
miniature circuit breaker suitable for inductive load of following poles in the existing
MCB DB complete with connections, testing and commissioning etc. as required. Double Pole Make: ABB, Havells, Schneider, Legrand, L&T. DSR 2.10.3
24
634
15216
... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required. 40Amp DSR 2.12.1
10
330
3300
... More
Supply & Erection of high power120 Watt LED Flood Light luminaries:
High-brightness White LEDs sources with high transmittance LENS on each LEDs with peanut lens with toughened glass, secondary lens optics, system lumen output of system luminous efficacy of ≥120 lm/W, 4000 K color temperature & CRI70 value for ensuring good quality light output. Life of at least 50,000 hours & LED driver efficiency 95%, potted driver and driver should comply cispr-15 and EMI/EMC compliance, Power factor greater than 0.90, THD15% & min 4KV internal surge protection and 10KV External surge protection with operating voltage range from 120-270 V for ensuring lifelong high performance of luminaire, having in built protection against short circuit, over voltage protection, the fixture is made of LM-6 Pressure die-cast aluminum with engraved company name & have IK05 & IP66 Class I protection with NABL Accredited LM-79 & LM-80 Report. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. The luminary should not be over power derived. The fitting shall be mounted on the plate bracket on existing pole including making connection, testing & energizing complete in all respect to the entire satisfaction of Engineer-in-charge. The LED Street Light Fixture shall be installed on 7.5/9 mtr long pole. The luminary should be make Philips/ Crompton/ Havells/ Surya/ Wipro/Bajaj.The detailed specification for supply of LED Street light luminaries is as under (with 02 years warranty). 1. Thermal Management system Good Thermal Management system Management of LED should be provided and LED must be Mounted on heat sink conductive Aluminum with suitable large area Surface by means of fins to disciple Heat to ambient air.
2. Applicable standard The fixture should confirm to Application BIS/IES standard/ IESNA LM 20
10
11537
115370
... More
S&E of Mouled Case Circuit Breakers (MCCB) of rating 63 Amp with Breaking Cap 16 kA, 415 Volts.
Supply & Erection of 3 pole, 16 kA, 63 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
4
3554
14216
... More
S&E of Mouled Case Circuit Breakers (MCCB) of rating 100 Amp with Breaking Cap 16 kA, 415 Volts.
Supply & Erection of 3 pole, 16 kA, 63 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
2
3928
7856
... More
Supplying and fixing brass batten/ angle holder including connection etc. as required. DSR 1.34
18
109
1962
... More
Supplying and fixing of following size of heavy duty ISI marked PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm DSR 1.21.2
20
124
2480
... More
S/F TPN MCB Supply and Fixing following rating, four pole, 415 volts, MCB TPN with box complete with connections tensing and commissioning etc as required. Make of Anchor, Havells, Legrand, ABB, L&T, Siemens,Schneider. The work shall be executed to the entire satisfaction of Engineer in charge. 63 Amps DSR 2.1.2
5
3073
15365
... More
Recovery of old material
-
-
-
... More
Less the cost of old ceiling fan
15
150
-2250
... More
Less the cost of old exhaust fan
6
100
-600
... More
Less the cost of old fitting 2'x2' of 36 watt
30
100
-3000
... More
Less the cost of Old MS Box
30
20
-600
... More
Less the cost of Old Copper wire
20
100
-2000
... More
Less the cost of old DB including MCCBs
3
1000
-3000
... More
Less the cost of Old MS Shutter
2
1000
-2000
Evaluation Notes How It Works ?
Potential Partner